HomeMy WebLinkAboutStory Cottage 13633 Carey Rd, Carmel architectural plansBSA LifeStructures
9365 Counselors Row Suite 300
Indianapolis, IN 46240-1478
ph 317.819.7878 fx 317.819.7288
www.bsalifestructures.com
DATE
BSALS PROJECT NO.
13633 CAREY RD. CARMEL, IN
STORY COTTAGE
10-BED MEMORY CARE HOME
21730002
G000
COVER SHEET
CLIENT PROJECT NO. - 21730002
OCT 23, 2019
SHEET INDEX
03- ARCHITECTURE
A100 FOUNDATION PLAN
A101 ARCHITECTURAL AND DIMENSION FLOOR PLANS
A130 REFLECTED CEILING PLAN
A200 MEZZ/ATTIC PLAN
A300 ROOF PLAN
A401 EXTERIOR ELEVATIONS
A402 EXTERIOR ELEVATIONS
A500 BUILDING SECTIONS
A501 WALL SECTIONS
A502 WALL SECTIONS
A503 WALL SECTIONS
A504 WALL DETAILS
A600 DETAILS AND INTERIOR ELEVATIONS
06/04/20
Mike Sheeks
99' - 3"5' - 9" 1' - 4" 22' - 1 3/8"9' - 10 7/8" 17' - 2" 5' - 7 7/8" 12' - 4 3/4"
1' - 4" 1' - 4"
NOTE: TYPICAL 1" OFFSET BETWEEN FACE OF
FOUNDATION WALL AND EXTERIOR FACE OF STUD.
2'-4" x 2'-4" CMU PIER W/ 4"
BRICK LEDGE (TYP. OF 4)4' - 7 1/2"22' - 0 1/8" 30' - 3 3/4" 17' - 1 1/2" 22' - 0 5/8" 1' - 4 1/4" 10" CMU W/ 4"
BRICK LEDGE
1' - 4 1/4"3' - 3 1/8" 5' - 8"12x12 CMU 12x12 CMU
10' - 5 5/8" 2' - 1" 7' - 5" 2' - 1" 12' - 7 7/8" 22' - 10 1/4" 7' - 5" 2' - 3 1/8"
FACE BRICK AND
FOUNDATION
12x12 CMU
LINE OF BEARING WALL ABOVE
8" CMU (TYPICAL)
10" CMU W/ 4"
BRICK LEDGE8' - 6"6 7/8"
6"6' - 5 1/2"5' - 5 1/4" 6' - 2 1/4" 5' - 2 5/8" 7' - 0 1/4" 3' - 7 1/4" 8' - 8 1/8" 10' - 0" 8' - 8" 4' - 6 3/4"2' - 10 1/8"9' - 9 5/8" 4' - 0" 11' - 2 3/4"8 7/8"15' - 11"BSA LifeStructures
9365 Counselors Row Suite 300
Indianapolis, IN 46240-1478
ph 317.819.7878 fx 317.819.7288
www.bsalifestructures.com
DESIGNEDDRAWNAPPROVEDBSALS PROJECT NO.
KEYPLAN
PLAN NORTH
DATE
D:\Users\DDurica\Documents\21730002-ARCH_BSALS_CENTRAL_v2018_DDurica.rvt10/23/2019 3:34:24 PM21730002
ApproverAuthorDesignerA100
FOUNDATION PLAN
10 -BED MEMORY CARE
HOME
STORY
COTTAGE
OCT 23, 2019
CLIENT PROJECT NO. - 21730002
1/4" = 1'-0"1 FOUNDATION PLAN
MARK DATE DESCRIPTION
06/04/20
Mike Sheeks
Vent HoodFRIDGERangeDryer Washer
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
DWSD
DW
FREEZER
SD
BEDROOM
--
BEDROOM
--
BEDROOM
--
BEDROOM
--
BEDROOM
--
LIBRARY
--
BEDROOM
--
BEDROOM
--
BEDROOM
--
BEDROOM
--
POWDER
BATH
--
PANTRY
--
KITCHEN
--
POWDER
BATH
--
BATHROOM
--
LAUNDRY
--
BEDROOM
--
SUN ROOM
--
DINING
--
ENTRY
--
CLOSET
--
GALLERY
--
HALL
--
A401
2
A401
1
A4022
A402 1
5
A500
5
A500
2
A500
2
A500
4
A500
4
A500
1
A500
1
A500
3
A500
ELEC. PANEL
D.SD.SD.SD.S D.SD.S101
101
101
101
101
101
101
112
115
116
116A 117A117
118A 119A
119
111A
STAIRS
111
110
127
126
122
123
125 125A 123A
102
121
121A 122A124101115
101 101
101
SH 4050
SH 3056
SH 3056
SH 3056
SH 3056
SH 3056 SH 30562-PLY 11 7/8" LVLSH 3060
SH 3060
SH 3060
SH 3060
SH 3060 SH 3060 SH 3060F 4060
SH 3060 SH 3060 SH 3060 SH 3060SH 3060 SH 3060 SH 3060 SH 3060
F 4050D.SD.S
D.SH.B D.SSH 3060
ALIGN
106
C.G
117
115
118
ALIGN
ALIGN
117
100
110
C.G
C.G
C.G
C.G
SH 3060
C.G SH 3060 C.G
C.G
C.G
105 1061
A502
1
A502 MM M M D
M M M WP
MWP
WP WPT
M
GFI
GFI
M10' - 8 3/4"
3
A502
3
A502
3
A503
6
A502
4
A503
1
A503
2
A503
TUB
SHOWER
2 PLY 14" LVL
2 PLY 11 7/8" LVL
5 OPEN SHELVES
GFI
SHAMPOO SINK
UPPER CAB.
3' - 0"
UPPER CAB.
3' - 0"
UPPER CAB.
3' - 0"
ROD/SHELF
3' - 2"
SH 3060
UNDER COUNTER
ICE MAKER
12' - 1 1/2"A600
1
PERGOLA AREA
114
5' - 3 1/2"
M
118
103
107
113
C.G
C.G
D.SSH 3060SH 3060SH 3060 3' - 6" 6' - 1 3/8" 11' - 9 3/4"4' - 4" 2' - 6"2'-6"
EQ
2'-6"
EQ
5' - 1 3/8" 4' - 7 1/4" 2' - 8 3/4"
2' - 1"
2' - 1"2' - 4"2' - 1"2' - 3"2' - 1"7' - 5 1/2" 6' - 0 7/8" 5' - 5 1/4" 6' - 2 1/4" 5' - 2 5/8" 10' - 9 3/4"7' - 4 1/4" 3' - 0 1/8"
2' - 4" 2' - 1"2' - 1"115A113A 2' - 1"2' - 4" 2' - 1"
2' - 1"2' - 4"2' - 1" 2' - 4" 2' - 1"2' - 1" 2' - 1" 2' - 4" 2' - 1"2' - 1"2' - 4" 2' - 1"2' - 1" 2' - 4" 2' - 1"
2' - 2 1/2"2' - 1" 2' - 1" 6' - 10 7/8"3' - 2" 1' - 3 3/4" 3' - 2" 14' - 1 1/4" 3' - 2" 1' - 3 3/4" 3' - 2" 14' - 1 1/4" 3' - 2" 9 5/8"9 5/8" 3' - 2" 7' - 8 1/2" 3' - 2" 14' - 1 1/4" 3' - 2"9 5/8"4 3/8"36' - 9 1/2" 6' - 8 1/4"2' - 2 1/4"4 3/8" 2' - 7 1/4" 3' - 2" 4' - 6 1/8" 3' - 2" 4' - 7" 3' - 2" 10' - 3 7/8" 3' - 2" 9" 3' - 2"6 1/2"10"EQ.10' - 6 5/8" 1' - 5 1/4"6' - 2" 3' - 3 3/8" 8' - 5" 3' - 5" 3' - 2" 2' - 0"8' - 5"
1205"3' - 2"13' - 6 5/8" 4 3/8"H.B.
2' - 8 3/4"
10 1/2"
4' - 0"
10 1/2"
3' - 7 1/2" 3' - 7 3/4" 3' - 0" 4' - 4 3/4" 1' - 6"
2 3/4"
3' - 2"
2 3/4"
1' - 6" 2' - 8 5/8" 1' - 11 1/4" 3' - 0" 4' - 1 7/8" 3' - 7 1/4" 2' - 8 1/2"
11 1/2"
3' - 6"
11 1/2"
2' - 8 1/2" 3' - 9 1/2" 3' - 0" 3' - 8 1/8"11 1/4" 5' - 9 1/8" 4' - 0" 3' - 0" 7' - 4 7/8" 3' - 0" 8' - 1 3/4" 3' - 0" 8' - 4 5/8" 3' - 0" 8' - 4 5/8" 3' - 0" 7' - 10 3/4" 3' - 0" 7' - 10 1/2" 3' - 0" 7' - 10 1/2" 3' - 0" 7' - 10 1/2" 3' - 0" 3' - 9 3/8"2' - 10 7/8" 5' - 1" 13' - 4 1/2"12' - 5" 5' - 7 3/4" 17' - 3" 9' - 9 7/8" 4' - 8 3/4" 11 1/4" 2' - 2 3/8"3' - 0" 3' - 0" 2' - 2 3/4" 3' - 0" 3' - 0" 5' - 0" 17' - 0"6 5/8"3' - 2"1' - 0 1/8" 21' - 11 1/2" EQ. 5' - 6"
12' - 3 1/8" 10' - 2 7/8"
7 3/4"
SH 3060
104
2' - 7 1/2" 3' - 0" 3' - 0" 3' - 5 3/4"7' - 4 7/8" 1' - 0 1/8"
3' - 0" 1' - 0" 3' - 0" 1' - 0" 3' - 0" 1' - 0" 3' - 0"
11 3/8"10' - 8 3/4"10' - 10 1/2" 10' - 10 1/2" 10' - 10 1/2" 10' - 10 1/2" 11' - 11" 10' - 10 1/2" 10' - 10 1/2" 10' - 8 3/4" 3' - 2" 4' - 6 1/4" 3' - 2" 7' - 2 3/8"8' - 8 7/8" 3' - 2"
1' - 1 1/4"2' - 7"3' - 2" 9' - 8 5/8" 8' - 8 1/2" 2' - 7 3/4" 4' - 9 7/8"5' - 1 1/4"9' - 7 5/8"3' - 0"2' - 8 3/4" 1' - 4 3/4"3' - 0"5' - 10 1/4" 5' - 6" 6' - 10 5/8"7' - 4 1/8" 5' - 1 1/4" 2' - 6"UTILITY SINK
1' - 1 5/8"
3' - 0"
1' - 6 1/8"
CABINET TO
ENCLOSE DEVICES
7' - 6 1/4"
121
122
A600 2
7' - 0" 8' - 2"A600
3
A600
4
5
A600
*CARPET
*CARPET
*CARPET
*CARPET
Room
--
123
123
123
123
123
6 1/2"3' - 2" 2' - 3" 2' - 6 1/2" 4 3/8" 7
A600
UP
123
123
123
*CARPET
DINING
TABLE
123
CARPET WIDTH
9' - 6"
WALK WAY W/O CARPET
8' - 0 5/8"7' - 0" 7' - 0"CENTER CARPET
INSET ON
FIREPLACE
1" R-ZIP SHEATHING W/ WATER
RES. BARRIER
1/8" JOINT W/ SEALANT
ZIP TAPE
TRIM BOARDS
1/8" JOINT W/ SEALANT
FCP LAP SIDING
WOOD FRAMING
INTERIOR SHEATHING
INSULATION WHERE
REQ'D
5/8"1/8" GAP W/ SEALANT
ZIP TAPE
TRIM BOARDS
1/8" GAP W/ SEALANT
FCP LAP SIDING
WATER RESISTIVE BARRIER
1" R-ZIP SHEATHING W/
WATER ERS BARRIER
INSULATION WHERE
REQ'D
WOOD FRAMING
INTERIOR GYP BD.
WOOD FRAMING
FCP LAP SIDING
SIDING STARTER COURSE
ZIP TAPE OVER FLASHING
STARTER STRIP
FLASHING
1/4" GAP, DO NOT CAULK
TRIM AROUND OPENING
TRIM BOARDS
1/8" GAP AND SEALANT
1" R-ZIP SHEATHING W/
WATER RESIS. BARRIER
FCP LAP SIDING
.MIN. 1-1/4" OVERLAP
WALL FRAMING
FIXTURE PENETRATION
BATT INSUL. AS SHOWN
INTERIOR GYPSUM BD
REFER TO PARTITION TYPE AS
NOTED ON PLAN FOR WALL
CONSTRUCTION
REFER TO PARTITION TYPE AS
NOTED ON PLAN FOR
PARTITION FINISH
PROVIDE STUD ARRANGEMENT
AS SHOWN @ CORNERS TYP.
U.N.O.
REFER TO PARTITION TYPE AS
NOTED ON PLAN FOR
PARTITION FINISH
NOTE: ALL SYMBOLS ARE SHOWN FOR CLARITY & COORDINATION -SEE
ELECTRICAL DESIGN-BUILD PLANS FOR EXACT LOCATIONS OF ELECTRICAL
EQUIPMENT & FIXTURES.
D
3
M
T
SWITCH
SWITCH-3 WAY
SWITCH DIMMER
SWITCH-MOTION SENSOR
CABLE TV
PHONE / DATA
FLOOR PHONE / DATA
THERMOSTAT
SD
WP
GFI
DUPLEX OUTLET
(TYP. @ 1'-6" A.F.F)
DUPLEX OUTLET-GFI
DUPLEX OUTLET- WEATHERPROOF
QUADPLEX OUTLET
FLOOR DUPLEX OUTLET
SMOKE DETECTOR
'#' SHOWN NEXT TO A SYMBOL INDICATES THAT THE FIXTURE'S HEIGHT A.F.F.
(ALL HEIGHTS ARE CENTERLINE OF FIXTURE)
ELECTRICAL LEGEND
KEYNOTE LEGEND
FLAT-PANEL TV OWNER. PROVIDE POWER, DATA & SUPPORT/MOUNTING BRACKET PER
OWNER DIRECTION
1X4 CORNER TRIM FROM B.O.SIDING TO B.O.SOFFIT.
MULTIPLE 15" DEEP CONT. STORAGE SHELVING.
FLOOR DRAIN.
VENT DRYER(S) TO EXT.
BOULEVARD 60" LINEAR DIRECT VENT FIREPLACE-REF. MANUFACTURER
INSTALLATION REQ.
VENT FIREPLACE TO ROOF ABOVE. REF BUILDING ELEVATIONS &
MANUFACTURER INSTALLATION INSTRUCTION.
DASHED LINE DENOTES FOOTING BELOW. REF BUILDING SECTIONS & WALL
SECTIONS.
DESCRIPTIONNO.
100
101
102
105
106
110
116
117
3 1/2" RESIDENTIAL SPRING HINGES AND A POSITIVE LATCHING PASSAGE SET ON
HALF DOOR.
120
7' WIDE FABRIC WRAPPED ACOUSTICAL PANEL ABOVE CABINETS TO CEILING.121
7' WIDE FABRIC WRAPPED ACOUSTICAL PANEL FROM FLOOR TO CEILING. (SEE
DETAIL 9/A600)
122
SCHLUTER-SCHIENE SAME-HEIGHT TRANSITION EDGE BETWEEN LVT AND
CARPETING IN BRASS. SEE DETAIL 7/A600.
123
GENERAL FLOOR PLAN NOTES
GENERAL CONTRACTOR AND / OR SUBCONTRACTORS ARE RESPONSIBLE FOR EXAMINING
AND CONFIRMING ALL SUBSTRATE CONDITIONS WHERE NEW MATERIALS ARE APPLIED.
SUBSTRATE SHALL BE SMOOTH, FREE OF DEFECTS AND SHALL CONFORM TO THE
REQUIREMENTS OF THE FINISHED MATERIAL MANUFACTURER'S RECOMMENDATION.
DO NOT SCALE DRAWINGS.
ALL DIMS TO BE FIELD VERIFIED. ARCHITECT TO BE NOTIFIED OF ANY DISCREPANCIES.
THE WORD "ALIGN" AS USED IN THESE DOCS SHALL SUPERCEDE ANY DIMENSIONAL
INFO INDICATED. IF DISCREPANCIES OCCUR, NOTIFY THE ARCHITECT IMMEDIATELY.
TYPICAL DIMENSIONS ARE TO THE FACE OF WOOD STUD, OR TO CENTER LINE OF STUD.
REFER TO PLAN DETAILS FOR ADDITIONAL DIMENSIONS.
ALL ANGLES SHOWN ARE 45°, 90°, OR 135° UNLESS NOTED OTHERWISE.
DO NOT SCALE THE DRAWINGS. WORKING FROM ESTABLISHED LINES AND POINTS,
ESTABLISH AND MAINTAIN DEPENDABLE MARKERS FOR LINES AND LEVELS OF WORK.
CALCULATE DIMS AND MEASURE FOR LAYOUT OF WORK. RECORD DEVIATIONS (IF ANY)
FROM DWG INFO ON EXIST CONDITIONS AND REVIEW WITH ARCHITECT/ENGINEER AT
TIME OF DISCOVERY.
FOLLOW WRITTEN DIMS AND LAYOUT POINTS ONLY. CONTRACTOR SHALL EXERCISE
SPECIAL CARE IN THE VERIFICATION OF ALL CONDITIONS AND DIMS IN THE LAYOUT OF
HIS WORK THE ALIGNMENT IN COORDINATION OF HIS WORK ITSELF AND OTHER
ADJACENT WORK IS OF PRIMARY IMPORTANCE AND SHALL TAKE PRECEDENCE OVER
DIMENSIONS, ESPECIALLY THOSE INDICATED AS APPROXIMATE. CONTRACTOR SHALL LAY
OUT AND VERIFY HIS WORK TO ENSURE ALIGNMENT AND FIT AND REPORT ANY
DISCREPANCIES IMMEDIATELY TO HIS SUPERINTENDENT AND THE ARCHITECT BEFORE
PROCEEDING OR PROCEED AT CONTRACTOR'S OWN RISK.
1
3
4
5
6
7
8
9
SLOPING CONCRETE SLAB TO FLOOR DRAINS IS OF PRIMARY IMPORTANCE AND SHOULD
TAKE PRECEDENCE OVER DIMENSIONS, ESPECIALLY THOSE INDICATED AS APPROXIMATE.
CONTRACTOR SHALL LAY OUT AND VERIFY HIS WORK TO ENSURE ALIGNMENT AND FIT,
AND REPORT ANY DISCREPANCIES TO THE OWNER'S REPRESENTATIVE.
10
THE GENERAL CONTRACTOR IS TO PROVIDE PROTECTION TO ANY COMPLETED WORK,
DURING CONSTRUCTION BY WHATEVER MEANS NECESSARY TO
MAINTAIN ANY COMPLETED FINISHES IN NEW CONDITION TO THE POINT OF OWNER MOVE-
IN AND ACCEPTANCE. ANY DAMAGED WORK, SCRATCHED, MARKED OR IN ANY WAY
IMPAIRED MATERIAL FOUND BY THE OWNER'S WILL BE REPLACED AT NO EXTRA COST TO
THE OWNER.
11
ALL PARTITIONS INDICATED ON THE FLOOR PLAN TO BE 2X4 WOOD STUD WITH 5/8"
DRYWALL UNLESS NOTED OTHERWISE.
13
ALL WOOD IN DIRECT CONTACT WITH CONCRETE TO BE PRESERVATIVE ROT RESISTANT
TREATED WOOD U.N.O.
18
SEE DOOR & FINISH SCHEDULE FOR ALL SCHEDULED DOORS, FRAMES TYPES , HARDWARE
AND DETAILS.
19
ALL FOUNDATION WALLS IN EXCAVATED AREAS TO BEAR ON AND BE FORMED BY
CLEANED, UNDISTURBED, VIRGIN SUB -SOIL.
22
ALL PENETRATIONS THROUGH RATED PARTITIONS (MECH, ELEC, AND PLUMB .) TO BE
FILLED WITH FIRE SAFING INSUL AND FIRE STOP SEALANT PER UL DESIGNS INDICATED.
27
THE ROOF FRAMING, FLOOR FRAMING, AND BEAM SIZES WILL BE DESIGNED BY SUPPLIER
SELECTED FOR PROJECT.
29
ALL EXTERIOR WINDOW AND DOOR HEADERS TO BE 2"X12"30
ALL BEDROOM FLOORING TO BE CARPET. ALL OTHER AREAS TO USE LVT FLOORING
UNLESS NOTED OTHERWISE.
31
BSA LifeStructures
9365 Counselors Row Suite 300
Indianapolis, IN 46240-1478
ph 317.819.7878 fx 317.819.7288
www.bsalifestructures.com
DESIGNEDDRAWNAPPROVEDBSALS PROJECT NO.
KEYPLAN
PLAN NORTH
DATE
D:\Users\DDurica\Documents\21730002-ARCH_BSALS_CENTRAL_v2018_DDurica.rvt10/23/2019 3:34:33 PM21730002
ApproverAuthorDesignerA101
ARCHITECTURAL AND
DIMENSION FLOOR PLANS
10 -BED MEMORY CARE
HOME
STORY
COTTAGE
OCT 23, 2019
CLIENT PROJECT NO. - 21730002
1/4" = 1'-0"1 GROUND FLOOR - ARCHITECTURAL FLOOR PLAN - OVERALL
1 1/2" = 1'-0"5 SHINGLE & TRIM OUTSIDE CORNER
1 1/2" = 1'-0" 4 SHINGLE & TRIM INSIDE CORNER
1 1/2" = 1'-0"3 FIXTURE PENETRATION
1 1/2" = 1'-0"2 CALIFORNIA CORNER FRAMING DETAIL
MARK DATE DESCRIPTION
06/04/20
Mike Sheeks
Vent Hood5
A500
2
A500
4
A500
1
A500
3
A500
5
A600
+10' -0"
+8' -6"
+10' -0"
+10' -0"
+9' -0"
+9' -0"
+9' -0"
+9' -0" +9' -0"
+9' -0"
+9' -0"
+9' -0"
+9' -0"
+9' -0"
+9' -0"
+9' -0"
+9' -0"
+9' -0"
+9' -0"
+9' -0"
+9' -0"
+9' -0"
+9' -0"
1" THICK FABRIC WRAPPED SPLINE -
MOUNTED ACOUSTICAL PANELS WITH
PERFORATED MINERAL-FIBER BOARD
CORE -BASIS OF DESIGN: GOLTERMAN &
SABO; Acousti-Tack ATM
DIMENSIONS FOR REFERENCE ONLY,
COORDINATE WITH OWNER 3' - 0"15' - 0" EQ. 8' - 0" EQ.
6
A600
Sim
1' - 6" 4' - 0" 4' - 0" 4' - 0" 1' - 6"LOCATION OF LIGHT FIXTURE ROUGH -IN,
CENTERED IN ACOUSTICAL PANEL
8
A600
Sim
BSA LifeStructures
9365 Counselors Row Suite 300
Indianapolis, IN 46240-1478
ph 317.819.7878 fx 317.819.7288
www.bsalifestructures.com
DESIGNEDDRAWNAPPROVEDBSALS PROJECT NO.
KEYPLAN
PLAN NORTH
DATE
D:\Users\DDurica\Documents\21730002-ARCH_BSALS_CENTRAL_v2018_DDurica.rvt10/23/2019 3:34:37 PM21730002
ApproverAuthorDesignerA130
REFLECTED CEILING PLAN
10 -BED MEMORY CARE
HOME
STORY
COTTAGE
OCT 23, 2019
CLIENT PROJECT NO. - 21730002
MARK DATE DESCRIPTION
1/4" = 1'-0" 1 GROUND FLOOR - REFLECTED CEILING PLAN
06/04/20
Mike Sheeks
SD
UP
5
A500
2
A500
1
A500
+ 116' - 11 1/8"
ATTIC BEYOND
ATTIC BEYOND
ATTIC BEYOND ATTIC BEYOND
204
204
204
6' - 1 1/4"6' - 2 3/4" 15' - 9"16' - 0" 16' - 0" 15' - 8" EQEQ 10' - 0"6"SMOKE DETECTOR
WH
F
4x1 FLOURESCANT
LIGHTS
ALIGN W/ WALL BELOW
-
5
A500
2
A500
4
A500
1
A500
3
A500
ATTICATTIC
FURN.
WH 111B
111C
111D
111E
109' - 11 1/8"
2C
S
MEZZANINE
STORAGE
--
A600
1
A600 2
COORDINATE TRUSS
LOCATIONS WITH LIGHTING
TO CENTER IN HALL
BSA LifeStructures
9365 Counselors Row Suite 300
Indianapolis, IN 46240-1478
ph 317.819.7878 fx 317.819.7288
www.bsalifestructures.com
DESIGNEDDRAWNAPPROVEDBSALS PROJECT NO.
KEYPLAN
PLAN NORTH
DATE
D:\Users\DDurica\Documents\21730002-ARCH_BSALS_CENTRAL_v2018_DDurica.rvt10/23/2019 3:34:41 PM21730002
ApproverAuthorDesignerA200
MEZZ/ATTIC PLAN
10 -BED MEMORY CARE
HOME
STORY
COTTAGE
OCT 23, 2019
CLIENT PROJECT NO. - 21730002
1/4" = 1'-0"1 MEZZANINE
1/4" = 1'-0" 2 MEZZANINE
MARK DATE DESCRIPTION
06/04/20
Mike Sheeks
ASPHALT SHINGLES
WP
ROOF SHEATING
15lb FELT
ICE & WATER
SHIELD
EAVE FLASHING BY
SHT. MTL. ROOFING
CONT'R
PRE-FAB WOOD
TRUSSES @ 24" O.C.
FASCIA BOARD
CONT. SOFFIT VENT
SMOOTH FCP SOFFIT
A IRFLO
W
AIRF
L
OW
W.P.
. .
AIR GAP 1" MIN.
ROOF TRUSSES
ROOF TRUSSES
BLOC
K
I
NG AS
RE
Q
'
D
E
A
SI
DE
ICE & WATER
SHIELD. ON
BOTH SIDES OF
ALL RIDGES TYP.
PLYWD. ROOF
SHEATHING
RIDGE VENT W/ WIND BAFFLE &
RIDGE CAP SHINGES
PROVIDE MIN.0.12 SQ FT OF
NET FREE VENT AREA PER
LINEAR FOOT @ RIDGE.
ROOF SHINGLES
FELT
UNDERLAYMENT
NOTE: NET FREE VENT AREA FOR
RIDGE VENT SHALL NOT BE ANY
GREATER THAN 50% OF THE TOTAL
NET FREE VENT AREA.
GUTTER ID
W (WIDTH)D (DEPTH) 3/4".B (DEPTH) A (WIDTH)GUTTER "A"
GUTTER "B"
W (WIDTH SIZE): D (DEPTH SIZE):
4"
5"
DOWNSPOUT ID:
D.S. "A" (X" NOMINAL)
D.S. "B" (X" NOMINAL)
A (WIDTH SIZE):
4"
5"
B (DEPTH SIZE):
3"
4"
2"
3"
NOTE: SEE ELEVATIONS FOR
GUTTER & DOWNSPOUT
MATERIAL
PLAIN RECTANGULAR
DOWN SPOUT
REMOVABLE H/D SCREEN
GUTTER THICKNESS PER
SMACNA TABLE 1-5
NOTE: EXPANSION JOINT COVER
PLATE AND EXPANSION JOINT
SIZED PER SMACNA
.B .
MIN PER
SMACNA
ROOFING NAILS FASTEND AT
APPROXIMATELY 6" TO 10"
ON CENTER (O.C.)SLOPEPERIMETER RAKE DRIP-
EDGE FLASHING
METAL(INSTALL OVER
UNDERLAYMENT AT RAKE.)
DOWNSLOPE PERIMETER
EAVE DRIP-EDGE FLASHING
METAL.
FORMED DRIP-EDGE
FASCIA BOARD OPTIONAL: GUTTER
BRACKET
K-STYLE GUTTER
FABRICATED GUTTER
SPACER, OR FERRULE
AND SPIKE
OPTIONAL: COMPATIBLE
SEALANT RECOMMENDED
ICE & WATER SHIELD
NOTES:
1. PERIMETER DRIP EDGE METAL FLASHING IS SUGGESTED TO BE A MINIMUM OF 26-
GAUGE PER-FINISHED/PAINTED GALVANIZED STEEL, 16-OZ. COPPER, .032-INCH THICK
PER-FINISHED ALUMINUM, OR AN EQUIVALENT LONGEVITY, CORROSION-RESISTANT
METAL.
2. THE PERIMETER ON THE ROOF DECK SHOULD PROVIDE A CONTINUOUS SOLID WOOD
NAILING SURFACE OVER WHICH TO APPLY THE SHEET METAL DRIP -EDGE FLASHING.
3. THE VERTICAL-FACE FLANGE OF SHEET METAL DRIP-EDGE FLASHING SHOULD BE OF
SUFFICIENT LENGHT TO PERMIT WATER TO DRIP OFF THE ROOF, AND INTO GUTTER
(IF PRESENT), WITHOUT AFFECTING THE UNDERLYING CONSTRUCTION DURING
TIMES OF NO WIND.
4. THE HORIZONTAL FLANGE (I.E. ROOF SIDE) OF SHEET METAL DRIP-EDGE FLASHING
SHOULD EXTEND APPROXIMATELY 2" TO 3" MINIMUM ONTO THE ROOF.
ASPHALT-
SATURATED
FELT,OR
OTHER
APPROVED
UNDERLAYMENT
PLAYWOOD OR
STRUCTURAL
WOOD
SHEATHING
TYP SIDING
WALL
CLADDING
UNDERLAYMENT
(By others. Lap
over step flashing
and up-turned roof
underlayment.)
METAL 'Z'-SHAPED
COUNTERFLASHING
STEPFLASHING (See Detail
S-9
CRICKET VALLEYS
SLOPED TO DRAIN
WOOD-FRAMED AND
SHEATHED CRICKET
BENEATH
MEMBRANE
FLASHING
GRANULATE-SURFACED MEMBRANE CRICKET
FLASING PLY(S) (Extend upper end of flashing 18"
min. upslope undre shiningles. See note 2.)
NOTES :
1. Detail drawn showing laminated shingle. Also applies to other styles.
2. In cold climates, where snow and ice are common it is recommended as an ice-dam protection membrane at all
potential ice damming locations such as develope eaves, valleys, crickets, around penetrations, and rake
edges. Consult local Building code requirements.
3. A cricket flasing is recommended for rising walls and other through-roof prnetrations greater than 24" in width to
prmote positive runoff. Extend flanges 6" minimun up wall and a minimum of 18" upslope (24" minimum is
suggested in ice and snow regions). Consider holding course of shingle(s) upslope from back and upper side of
cricket to promote drainage.
4. Sheet metal step flashings are suggested to be a minimum of 26-gauge pre-finished/painted galvanized steel, 16
oz.copper, .032-inch thick pre-finished aluminium, or an equivalent longevity non-corrisive metal.
5. Consider specifyng the extension of roofing underlayment vertically up the wall so that it is over lapped by the wall
cladding underlayment.
6. Dimentions shown are recommended minimums and are intended to be approximate to allow for resonable
tolerances due to field conditions.
7. The profile of specific components, their cofiguration or sequencing, can vary with the roof system, with climatic
differences, and regional or area practices.
DOWNSLOPE PERIMETER
EAVE DRIP-EDGE
FALSHING METAL (Install
underneath underlayment at
eave.)
LEADING EDGE PLUS
STARTER COURSE
START FIRST COURSE WITH
FULL SHINGLE
TYPICAL EXPOSURE PER
SHINGLE MFGR.
4" MINIMUM END LAP
2" MINIMUM SIDE LAP
SECURE WITH
CODE-REQUIRED
NUMBER OF NAILS
SELF-ADHERED ICE &
WATER MEMBRANE
(extend minimum 24"
inside exterior wall line.
SELF-ADHERED ICE & WATER
MEMBRANE AT ALL VALLEYS
TYP.
APPROXIMATELY 6" LAP
ASPHALT-SATURATED FELT,
OR OTHER APPROVED
UNDERLAYMENT
NOTES:
1. AN ICE & WATER PROTECTOR MEMBRANE AS AN ICE-DAM PROTECTION MEMBRANE
AT ALL POTENTIAL ICE DAMMING LOCATIONS SUCH AS DOWNSLOPE EAVES,
VALLEYS, CIRECKETS, ARROUND PENETTRATIONS , AND RAKE EDGES. AT DOWNSLOPE
ROOF PERIMETERS IT IS RECOMMENDED TO EXTEND THE ICE DAM PROTECTION
MEMBRANE 24" MIN. UPSLOPE FROM EXTERIOR WALL.
2. RECOMMENDED MINIMUM SLOPE FOR INSTALLATION OF ASPHAT SHINGLES IS 4:12,
IF ONLY ONE LAYER OF NO.15 ASPHALT SATURATED FELT OR OTHER APPROVED
WATER-SHEDDING UNDERLAYMENT, SUCH AS IKO STORMTITE,IS SPECIFIED. FOR
ROOF SLOPES LESS THAN 4:12 A MINIMUM OF TWO LAYERS OF UNDERLAYMENT IS
TO BE INSTALLED "SHINGLE" FASHION WITH A 17"EXPOSURE AND 19" SIDELAP.
SHINGLES NOT RECOMMENDED FOR SLOPES LESS THAN 2:12.
24" (See Note 2.)
L.P EAVE
EL. 112'-4"
D.S. "A" 3
1
4
4
3
D.S. "A"
L.P EAVE EL. 109'-111/8"
GUTTER "A"
L.P EAVE
D.S. "A"
EL. 116'-6 9/16"
GUTTER "A"
4
3 6
4
1
D.S. "B"
GUTTER "B"
L.P EAVE
EL. 109'-11 1/8"
3
5
1
2
4
L.P EAVE
EL. 109'-11 1/8"3
1
8
2 5 4 3
GUTTER "A"
8 3 4
3
2
1
L.P EAVE
EL. 109'-11 1/8" GUTTER "A"GUTTER "A"
GUTTER "A"
L.P EAVE
EL. 109'-11 1/8"
GUTTER "A"
4
2
1
H.P RIDGE #4
EL. 118'-3 3/8"
5
3
4
2
1
H.P RIDGE #4
EL. 120'-6 11/16"
H.P RIDGE #1
EL. 122'-7 9/16"RIDGEL.P . EAVE
EL. 118'-3 3/8"
GUTTER "B"
D.S. "B" 4
H.P RIDGE #1
EL. 116'-15/8"
SLOPE
DOWN
APPROX.
5:12
RIDGESLOPE
DOWN
APPROX.
5:12
3
2
8
5
SLOPE
DOWN
APPROX.
5:12
SLOPE
DOWN
APPROX.
5:12
10
2
5
3
8
H.P RIDGE #3
EL. 118'6 9/16"SLOPEDOWNAPPROX.9:12SLOPEDOWNAPPROX.9:12EL. 109'-11 1/8"
D.S "A"
D.S "A"
GUTTER "A"
D.S "A"
VA
L
LEY VALL
E
Y
SLOPEDOWNAPPROX.9:12SLOPEDOWNAPPROX.9:12SLOPE
DOWN
SLOPE
DOWN
3
8
5
3
RIDGESLOPEDOWNAPPROX.9:12SLOPEDOWNAPPROX.9:125
3 8
H.P RIDGE #6
EL. 115'-7 1/2"
D.S "A"
SLOPE
DOWN
SLOPE
DOWN
D.S "A"
D.S "A"SLOPEDOWNAPPROX.9:12SLOPEDOWNAPPROX.9:12VAL L EY
A600
1
A600 2 SLOPEICE & WATER SHIELD EXTENDED 24" PAST INSIDE
FACE OF EXTERIOR WALL
ROOFING NAILS FASTEND AT
APPROXIMATELY 6" TO 10" ON
CENTER (O.C.)
PERIMETER RAKE DRIP-EDGE
FLASHING METAL (INSTALL
OVER UNDERLAYMENT AT
RAKE.)
DOWNSLOPE PERIMETER EAVE
DRIP-EDGE FLASHING METAL
(INSTALL UNDEMEATH
UNDERLAYMENT AT EAVE.
TRIM AND BEND IN END AT
CORNER TO FORM CLOSED.)
FORMED DRIP-EDGE
FASCIA BOARD
NOTES:
1. A SELF-ADHERING ICE & WATER MEMBRANE TO BE INSTALLED AT ALL POTENTIAL ICE
DAMMING LOCATIONS SUCH AS DOWNSLOPE EAVES, VALLEYS, CRICKETS, AROUND
PENETRATIONS, AND RAKE EDGES. AT DOWNSLOPE ROOF PERIMETERS IT IS
RECOMMENDED TO EXTEND THE ICE DAM PROTECTION MEMBRANE 24" MIN.
UPSLOPE FORM EXTERIOR WALL.
2. THE PERIMETER OF THE ROOF DECK SHOULD PROVIDE A CONTINUOUS SOILD WOOD
NAILING SURFACE OVER WHICH TO APPLY THE SHEET METAL DRIP-EDGE FLASHING.
3. THE VERTICAL-FACE FLANGE OF SHEET METAL DRIP-EDGE FLASHING SHOULD BE OF
SUFFICIENT LENGTH TO PERMIT WATER TO DRIP OFF THE ROOF WITHOUT
AFFECTING THE UNDERLYING CONSTRUCTION DURING TIMES OF NO WIND.
4. THE HORIZONTAL FLANGE (I.E., ROOF SIDE) OF SHEET METAL DRIP-EDGE FLASHING
SHOULD EXTENDED APPROXIMATELY 2" TO 3" MINIMUM ONTO THE ROOF.
5. INCOLD CLIMATES, CONSIDER INSTALLATION OF AN ISOLATOR SHEET (E.G., A STRIP
OF ASPHALT-SATURATED FELT) BETWEEN THE WOOD ROOF DECK AND SHEET
METAL FLASHING FLANGE(S) TO MINIMIZE POTENTIAL FOR CONDENSATION AND
RESULTING DECAY.
EXAMPLE: METAL
FLASHING WITH
STORM COLLAR
EXAMPLE:
PRE-FABRICATED
FLASHING COLLAR
ALTERNATE:
SEPARATE SOFT
METAL FLASHING
CAP,INTO PIPE
APPROX 1"
ALTERNATE: SEPARATE
SOFT METAL FLASHING
CAP,
FASTEN THROUGH
UPSLOPE FLANGE (I.E.,
BLIND-NAIL.) TO SECURE
VENT FLASHIN
DRAWBBAND
COMPLETBLE
SEALANT
STOR
COOLER
METAL PIPE FLASHING
SOIL STACK PIPE
(PLUMBING VENT.)
LEAD OR OTHER SOFT METAL
PIPE FLASHING (TURN DOWN
INTO SOIL STACK
APPROXIMATELY 1".)
NOTES:
1. SOIL PIPE STACKS SHOULD EXTEND A MINIMUM OF 8" ABOVE ROOF SURFACE.
2. IF EXPOSED FASTENERS ARE PLACED THROUGH VENT'S DOWNSLOPE FLANGE, THEY
SHOULD BE WEATHERTIGHT, GASKETED FASTENERS (E.G., RING-SHANK NAILS OR
SCREWS).
3. IT MAY BE THAT THE LAYOUT OF THE SOIL PIPE PENETRATION OCCURS IN SUCH A
WAY THAT AN ASPHALT SHINGLE BUTT-END JOINT, OR SHINGLE TAB CUTOUT,
ALIGNS WITH THE EDGE AND/OR BACK OF THE METAL FLASHING'S FLANGE. IN THIS
CASE, INSTALL A PRESSURE-SENSITIVE SELF-ADHERED MODIFIED-ASPHAL
MEMBRANE TO STRIP-IN THE SIDES AND BACK OF THE METAL FLASHING FLANGE TO
EFFECTIVELY EXTEND THESE FLANGES.
CLADDING (FIBER-CEMENT LAP CLADDING SHOWN. LAP 2"
MINIMUM OVER STEP FLASHING AND MAINTAIN ABOVE ROOF
SURFACE. SEE METAL COUNTERFLASHING DETAIL)
WALL CLADDING UNDERLAYMENT(LAP
OVER STEP FLASHING AND UP-TURNED
ROOF UNDERLAYMENT.)
EXTENSION OF ICE & WATER SHIELD
(TURNED UP AT WALL.)
APRON FLASHING VERTICAL FLANGES
(APPROXIMATELY 4", AND SAME
UPSLOPE.)
APRON FLASHING DOWNSLOPE FLANGE
(APPROXIMATELY 5".(FABRICATE WITH
HEMMED EXPOSED/LEADING EDGES.))
STEP FLASHING (EXTEND BOTTOM PIECE
PAST CORNER. (OPTIONAL: INJECT
SEALANT INTO CORNER.)
APRON FLASHING SIDE FLANGE(4"
MINIMUM EXTENSION PAST CORNER.)
METAL
STEP
FLASHING
APRON FLASHING
SHOP FORM
FLASHING WITH
SOLDERED CORNERS
HEMMED EDGES
NOTES:
1. SHEET METAL STEP AND APRON FLASHINGS ARE SUGGESTED TO BE A MINIMUM OF
26-GAUGE PRE-FINISHED/PAINTED GALVANIZED STEEL 16 OZ. COPPER, .032-INCH
THICK PRE-FINISHED ALUMINNUM, OR AN EQUIVALENT LONGEVITY NON-CORROSIVE
METAL.
2. VERTICAL FLANGE OF STEP FLASHING SHOULD BE LAPPED A MINIMUM OF 2". SHEET
METAL COUNTERFLASHING MAY BE OPTIONAL WHERE WALL CLADDING OR SIDING
OVERLAPS STEP FLASHING.
3. EXTEND ROOFING UNDERLAYMENT VERTICALLY UP THE WALL SO THAT IT IS
OVERLAPPED BY THE WALL CLADDING UNDERLAYMENT.
KEYED ROOF PLAN NOTES
1. ICE & WATER SHIELD.
2. ASPHALT SHINGLE.
3. MTL DRIP EDGE AT ROOF EDGE. SEE DIAGRAM 9 / A300.
4. MTL DRIP EDGE WITH K-STYLE GUTTER AT ROOF EDGE. SEE DIAGRAM 8 / A300.
5. RIDGE VENT. SEE DETAIL 3 / A300.
7. PIPE STACK. REF PLUMB FOR SIZE AND LOCATION. SEE DETAIL. 10 / A300 AND DIAGRAM.
8. SEE DIAGRAM 11 / A300 FOR APRON AND STEP FLASHING AT SIDEWALL AND DORMERS.
10. FIREPLACE FLUE. REF BUILDING SECTION ON A500 FOR REQ'D HEIGHT. REF
MANUFACTURER'S INSTALLATION INSTRUCTIONS.
X
GENERAL ROOFING PLAN NOTES
ALL SHEET METAL TO BE INSTALLED IN ACCORDANCE WITH SMACNA STANDARDS.1.
REF. SHADED AREA ON ROOF PLAN. PROVIDE ICE & WATER SHIELD MEMBRANE
UNDERLAYMENT AT:
2.
1. EAVES - FROM EDGE OF GUTTER OVERHANGE AND EXTEND UP ON TO
ROOF 24" PAST INSIDE FACE OF INTERIOR WALL.
2. ROOF VALLEYS-PROVIDE FOR FULL MATERIAL WIDTH OF MEMBRANE
(36" WIDE) CENTER ON VALLEY FOR ENTIRE LENGHT.
3. ROOF RIDGES - ON BOTH SIDES OF RIDGE VENT AT ROOF RIDGES.
4. DORMERS & SIDEWALLS - ON ROOF AT SIDE & DORMER WALLS. TURNED
AND EXTENDED UP WALL.
5. RAKE, EDGES - ALONG THE RAKE EDGE EXTENDED UP ONTO ROOF 24"
PAST INSIDE FACE OF INTERIOR WALL.
6. ALONG EVERY WALL CHIMNEY, & ROOF PENETRATION WHERE
FLASHING WILL BE INSTALLED
BSA LifeStructures
9365 Counselors Row Suite 300
Indianapolis, IN 46240-1478
ph 317.819.7878 fx 317.819.7288
www.bsalifestructures.com
DESIGNEDDRAWNAPPROVEDBSALS PROJECT NO.
KEYPLAN
PLAN NORTH
DATE
D:\Users\DDurica\Documents\21730002-ARCH_BSALS_CENTRAL_v2018_DDurica.rvt10/23/2019 3:34:47 PM21730002
ApproverAuthorDesignerA300
ROOF PLAN
10 -BED MEMORY CARE
HOME
STORY
COTTAGE
OCT 23, 2019
CLIENT PROJECT NO. - 21730002
1 1/2" = 1'-0"2 EAVE DETAIL
1 1/2" = 1'-0"3 RIDGE VENT
1 1/2" = 1'-0"5 GUTTER SIZING DETAIL
1 1/2" = 1'-0"8 DRIP-EDGE METAL & GUTTER
1/2" = 1'-0"6 CRICKET VALLEYS@CHIMNEYS
3/16" = 1'-0"7 ICE DAM @ VALLEY & EAVE
1/8" = 1'-0"1 ROOF PLAN
1 1/2" = 1'-0"9 DRIP-EDGE METAL
1 1/2" = 1'-0"10 SOIL PIPESTACK
1 1/2" = 1'-0"11 APRON & STEP FLASHING
MARK DATE DESCRIPTION
06/04/20
Mike Sheeks
B.O.F.
96' - 4"
GROUND
100' - 0"
MEZZANINE
109' - 11 1/8"
5
A500
4
A500
3
A500
118' - 3 3/8"
109' - 11 1/8"
120' - 6 3/4"
122' - 10 5/8"
121' - 3 3/8"
118' - 6 5/8"
111' - 8 3/8"
BLACKED OUT GLASS AT
ALL DORMER WINDOWS
ASPHALT SHINGLE
DASHED LINE DENOTES LOCATION OF
FLASHING, TYP. REF. A2.10 ROOF DETAILS
FIBERBOARD TRIM
FIBER COMPOSITE PANEL
PREFIN. SHEETMETAL GUTTERS & D.S
GFRC OR OTHER APPOVED
MATERIALS REF. FRONT PORCH
COLUMN DETAILS
SH 4050 SH 3060
101
SH 3060 F 4050 SH 3060
101
101
101
FIBER COMPOSITE PANEL
RIDGE VENT
ASPHALT SHINGLE
SHEET METAL AWNING
PREFIN. SHEETMETAL
GUTTERS &D.S
FIBERBOARD TRIM
FIBERBOARD TRIM
FIBER COMPOSITE PANEL
SIDING
HOSE BIB
B.O.F.
96' - 4"
GROUND
100' - 0"
MEZZANINE
109' - 11 1/8"
5
A500
4
A500
3
A500
118' - 6 5/8"
122' - 10 5/8"
116' - 6 5/8"
122' - 7 5/8"
F 4060 SH 3060 SH 3060 SH 3056SH 3056
116' - 1 5/8"
RIDGE VENT
ASPHALT SHINGLE
PREFIN. SHEETMETAL GUTTER & D.S
FIBERBOARD TRIM WEATHERPROOF HOSE BIBB,
REF. PLAN
101
101
DASHED LINE DENOTES
LOCATION OF FLASHING, TYP.
REF. A2.10 ROOF DETAILS
FIBERBOARD TRIM
DASHED LINES DENOTES
LOCATION OF FLASHING,TYP. REF.
A2.10 ROOF DETAIL 101
101
RIDGE VENT
ASPHALT SHINGLE
FIBER CEMENT SIDING
FIBER COMPOSITE PANEL
101
FIBER BOARD TRIM
APPR
O
X
.
SH 3060 SH 3060
BSA LifeStructures
9365 Counselors Row Suite 300
Indianapolis, IN 46240-1478
ph 317.819.7878 fx 317.819.7288
www.bsalifestructures.com
DESIGNEDDRAWNAPPROVEDBSALS PROJECT NO.
KEYPLAN
PLAN NORTH
DATE
D:\Users\DDurica\Documents\21730002-ARCH_BSALS_CENTRAL_v2018_DDurica.rvt10/23/2019 3:34:53 PM21730002
ApproverAuthorDesignerA401
EXTERIOR ELEVATIONS
10 -BED MEMORY CARE
HOME
STORY
COTTAGE
OCT 23, 2019
CLIENT PROJECT NO. - 21730002
1/4" = 1'-0"2 SOUTH ELEVATION
1/4" = 1'-0"1 NORTH ELEVATION
MARK DATE DESCRIPTION
06/04/20
Mike Sheeks
B.O.F.
96' - 4"
GROUND
100' - 0"
MEZZANINE
109' - 11 1/8"
2
A500
1
A500
SH 3060 SH 3060 SH 3060 SH 3060SH 3060
112
2.5:122.5:12
F 3012F 3012 F 3012 F 3012F 3012 2' - 1 1/4"2' - 1 1/4"SH 3056 SH 3056 SH 3056 SH 3056
DASHED LINE DENOTES
FLASHING, TYP. REF. DETAILS
ON A2.10 ROOF PLAN
122' - 7 5/8"
112' - 9 3/8"
116' - 6 5/8"
RIDGE VENT
ASPHALT SHINGLE
PREFIN. SHEETMETAL GUTTER
& D.S
FIBER CEMENT SIDING
101
A PPR OX.APPROX.
111' - 3"
101
FIBER CEMENT SIDING
9"DASHED LINE DENOTES
FLASHING, TYP. REF. DETAILS
ON A2.10 ROOF PLAN
PREFIN. SHEETMETAL GUTTERS & D.S
FIBER CEMENT SIDING
101 101
FIBER CEMENT SIDING
PREFIN. SHEETMETAL
GUTTERS & D.S
101
FP VENT
BRICK
121' - 3 3/8"
SH 3060
109' - 11 1/8"
104
B.O.F.
96' - 4"
GROUND
100' - 0"
MEZZANINE
109' - 11 1/8"
2
A500
1
A500
122' - 10 5/8"
FIBER CEMENT SIDING
101
RIDGE VENT
FIBERBOARD TRIM
FIBER CEMENT SIDING
FIBERBOARD TRIM
2' - 1 1/4"2' - 1 1/4"SH 3060 SH 3060 SH 3060 SH 3060 SH 3060 SH 3060 SH 3060 SH 3060
124
101 WEATHERPROOF
HOSE BIBB, REF.
PLAN
FIBERBOARD TRIM
ASPHALT SHINGLE
RIDGE VENT
PREFIN. SHEETMETAL
GUTTERS & D.S
101
109' - 11 1/8"
5
A600
BSA LifeStructures
9365 Counselors Row Suite 300
Indianapolis, IN 46240-1478
ph 317.819.7878 fx 317.819.7288
www.bsalifestructures.com
DESIGNEDDRAWNAPPROVEDBSALS PROJECT NO.
KEYPLAN
PLAN NORTH
DATE
D:\Users\DDurica\Documents\21730002-ARCH_BSALS_CENTRAL_v2018_DDurica.rvt10/23/2019 3:35:00 PM21730002
ApproverAuthorDesignerA402
EXTERIOR ELEVATIONS
10 -BED MEMORY CARE
HOME
STORY
COTTAGE
OCT 23, 2019
CLIENT PROJECT NO. - 21730002
1/4" = 1'-0"1 EAST ELEVATION
1/4" = 1'-0"2 WEST ELEVATION
MARK DATE DESCRIPTION
06/04/20
Mike Sheeks
B.O.F.
96' - 4"
GROUND
100' - 0"
MEZZANINE
109' - 11 1/8"
5
A500
4
A500
3
A500
APPR
O
X
.
4
1
/2" /1/2"
APPRO
X
.
4
1/2 " /1/2 "
4 1/
2
"
/ 12"
4 1 /2" / 12"
B.O.F.
96' - 4"
GROUND
100' - 0"
MEZZANINE
109' - 11 1/8"
2
A500
1
A500
RIDGE VENT
113 113
SH 3060
112
RIDGE VENTDORMER TRUSS BEARING
118' 0 5/8"
105
B.O.F.
96' - 4"
GROUND
100' - 0"
MEZZANINE
109' - 11 1/8"
2
A500
1
A500
DORMER TRUSS BRG PT
118' 0 5/8"
B.O.F.
96' - 4"
GROUND
100' - 0"
MEZZANINE
109' - 11 1/8"
5
A500
4
A500
SH 3056SH 3056
113
GROUND
100' - 0"
MEZZANINE
109' - 11 1/8"
2
A500
MIN 6' CLEARANCE STAIR TREAD TO
CIELING MUST BE MAINTAINED
4' - 0"16 TREADS @
11"/ TREAD=14'-8"
STAIR TO BE
FINISHED WITH
WOOD GRADE
FLOOR PAINT
FINAL RAILING HEIGHT
AFF BETWEEN 34" AND 38"
MAINTAIN 36" CLEAR
LANDING
3' - 0"9' - 11 1/8"17 RAISERS @7"/ RISER=1' - 0"
KEYNOTE LEGEND
ATTIC ACCESS DOOR TYP, SIZE, AND LOCATION TO
BE VERIFIED W/ OWNER.
DESCRIPTIONNO.
113
204
PROVIDE ROOF CAVITY INSULATION VENTS WHERE GYP. BD.
CEILING PREVENTS ATTIC AIRFLOW.
BSA LifeStructures
9365 Counselors Row Suite 300
Indianapolis, IN 46240-1478
ph 317.819.7878 fx 317.819.7288
www.bsalifestructures.com
DESIGNEDDRAWNAPPROVEDBSALS PROJECT NO.
KEYPLAN
PLAN NORTH
DATE
D:\Users\DDurica\Documents\21730002-ARCH_BSALS_CENTRAL_v2018_DDurica.rvt10/23/2019 3:35:09 PM21730002
ApproverAuthorDesignerA500
BUILDING SECTIONS
10 -BED MEMORY CARE
HOME
STORY
COTTAGE
OCT 23, 2019
CLIENT PROJECT NO. - 21730002
3/16" = 1'-0"2 BUILDING SECTION-2
3/16" = 1'-0"4 BUILDING SECTION-4
3/16" = 1'-0"5 BUILDING SECTION-6
3/16" = 1'-0" 1 BUILDING SECTION-1
3/16" = 1'-0" 3 BUILDING SECTION-3
MARK DATE DESCRIPTION
06/04/20
Mike Sheeks
10'-2 1/8"6'-8 1/2"3'-8" 2'-2 3/8"8'-9 7/8" 11'-8 3/8"7'-10 1/2"8" 2'-2 3/8" 7' 1/4"6'-7 1/2"1'-11"
1'-11" 11"
2'-4"
14'-10"4'-0-1/2" R.O.3'--6 1/2" 11/2" CAVITY
10 1/8"4'-6 1/2" R.O.10'-2 5/8"2'-2" LEVEL 1 - FF
100'-0"
TRUSS BRG. PT.
110-2 5/8"
BOT. FTG.
96'-4"
BOT. FTG.
96'-4"
DORMER RIDGE
SEE ROOF PLAN
RIDGE #1
SEE ROOF PLAN
ATTIC
ASPHALT SHINGLES ON
BLDG. FELT UNDERLAYMENT
ON 5/8" EXTER. GR. PLYWD.
TRUSS BRG. PT.
110-2 5/8"
SINGLE HUNG VINYL WINDOW
/ "BLACKED OUT"
SINGLE PANE GLAZING
4" COMOSITE WINDOW
TRIM (PAINT)
ASPHAPLT SHINGLES ON
ICE & WATER SHILED
UNDERLAYMENT ON
5/8" EXTR. GR. PLYWD.
PREFIN. SHT. MTL.
GUTTER
12" COMPOSITE
TRIM
COMPOSITE CROWN
MOULD GPM-165
(PAINT)
SMOOTH FINISH FIBRE
CEMENT FASICA & SOFFIT PANELS (PAINT)
OVER 1/2" WOOD SHEATHING
AT BEAM COVER
BEAM, PER STRUCT.
COLUMN, PER STRUCT.
VENTED GGRFC
TRAPPED COLUMN
COVER W/ BASE
& CAPITAL
CAULK COLUMN BASE
AT PERIMETER
PRECAST CONCRETE CAP
FACE BRICK VENEER W/
MAS. TIES AT 16" O.C. EA. WAY
ON WEATHER RESISTANT
BARRIER ON 1/2" WD. SHTHG.
W/ 2X4 WD. STUD FARMING
AT 16" O.C.
LAWN
8" CMU COLUMN
W / STEEL RENIFORCING,
CONCRETE COLUMN
FOOTING
RIDGE VENT,
SEE ROOF PLAN
RIDGE VENT , SEE ROOF PLAN
ENGINEERED PRE-FAB 2x
WOOD TRUSSES AT 24" O.C.
DORMER FRAMING
R.O. AT HEAD
BUILT UP 2x WD. LINTEL,
PER STRUCT.
BUILT UP WD. HEADERS,
PER STRUCT.
LIGHT FIXTURE, SEE
REFLECTEDD CLG. PLAN
SMOOTH FINISH FIBER
CEMENT SOFFIT PANEL
(PAINT)
2x4 WOOD FRAMING
AT 16" O.C.
4" CONC. PAD
ON 4" COMPACTED
GRANULAR BASE
LEVEL 1 - FF
100'-0"3'-8" BRICK SHEL 8" BELOW
FINISH FLOOR
COMPOSITE CROWN
MOULD GPM-58( PAINT)
STEEL ANGLE BRICK SHELF,
PER STRUCT.
SINGLE HUNG VANYL
WINDOW W/
1/2" INSUL. GLASS
CONC. FOOTING,
10" CMU FOUNDATION WALL
GROUT SOLID W/ STEEL
REIFORCING ,
R-10 RIGD INSUL. AT FDN.
PERIMETER VERTICAL 2'-0" HIGH
MIN. R-42 INSUL.
ENGINEERED PRE-FAB 2x
WOOD TRUSSES AT 24" O.C.
1/2" GYPSUM BD.
ON VAPOR BARRER
1/2" GYPSUM BD.
2x4 WOODFRMING
AT 16" O.C.
R-13 KRAFT FACE BATT INSUL.
LINTEL, PER STRUCT.
1x WOOD TRIM (PAINT) AT
PERIMETER SILL, JAMBS
& HEAD, TYP.
WOOD TRIM CASING
APRON, JAMBS & HEAD (PAINT)
2x4 WD. FRAMING AT 16" O.C.
R-13 KARFT FACE BATT INSUL.
1/2" GYPSUM BD.
SILL SEALER
WOOD BASE GPM-503 (PAINT)
FLOOR FINISH-SEE SCHEDULE
4"CONC.SLAB ON GRADE ON
VAPOUR BARRER ON
12"PEA GRAVEL FILL
BUILTUP WC. HEADERS,
PER STRUCT.
ENGINEERED PRE-FAB 2x
WOOD TRUSSES AT 24" O.C.
MAIN ROOF FRAMING
R.O. AT SILL
2 4
2 4
2 4
2 4
2 4
2 4
2 4
2 4 2 4
2 4
2 4
2 4
2 4
2 4
A504
1 SIM.
A504
2 SIM.
A504
3 SIM.
A504
4 SIM.
A300
3
8". CMU
FIBER CEMENT PANEL
SIDING LAPPED ON
1" ZIP SYSTEM INSULATED
R-SHEATHING (R-3.6)
2 4
2 42 4
2 4
2 4 2 4424242424
24242422X4 WOOD STUD
FRAMING
WOOD POST
FACE BRICK VENEER
W/ MASSONARY TIES
ON WEATHER RESISTANT
BARRER ON 1/2" WOOD
SHEATHING
2'-4"2'-4"
VENTED GFRC
TAPERED COLUMN
COVER W/ BASE
& CAPITAL
WOOD POST
MEMBRANE FLASHING
AT CAP STONE FOR
COLUMN BASE
PRECAST
CONCRETE CAP
2'-7" 2'-7"10
12
ASPHALT SHINGLES ON
BLDG FELT UNDERLAYMENT
ON 5/8" EXTR. GR. PLYWD.
ASPHALT CAP SHINGLES
AT DORMER RIDGES &HIPS,
TYPICAL
SINGLE HUNG VINYL
WINDOW W/
"BLACKED OOUT"
SINGLE PANE GALZING
MTL. STEP FLASHING
AT DORMER SIDES
SMOOTH FINISH
FIBRE CEMENT
PANE S (PAINT)
BASE FLASHING AT
DORMER SILL
F 2840
1
A501
Sim
5
A501
Sim
8".RIDGE VENT,
SEE ROOF PLAN
ENGINERED PRE-FAB 2x
WOOD TRUSSES AT 24" O.C.
ATTIC
RIDGE #1
SEE ROOF PALN
DORMER RIDGE
SEE ROOF PLAN
DORMER TRUSS BRG PT
118'-1 1/8"
ASPHALT CAPSHINGLES
AT DORMER RIDGES & HIPS, TYP.
ASPHALT SHINGLES ON
BLDG. FELT UNDERLAYMENT
ON 5/8' EXTR. GR. PLYWD.
SMOOTH FIBRE CEMENT PANEL SIDING
RETURN AT CORN RS, TYP.
FIBRE CEMENT PANEL SIDING
LAPPED ON 1" ZIP SYSTEM INSULATED
R-SHEATHING (R 3.6)
DORMER
ELEVATION
PREFIN. SHT. MTL. CURB PROFILE AT
DORMER SIDES AND FRONT AT MAIN
ROOF
ASPHALT SHINGLES ON
ICE & WATER SHIELD
UNDERLAYMENT ON
5/8" EXTER. GR. PLYWD.
ENGINEERED PRE-FAB 2x
WOOD TRUSSES AT 24" O.C.
4
A501
A300
3
BSA LifeStructures
9365 Counselors Row Suite 300
Indianapolis, IN 46240-1478
ph 317.819.7878 fx 317.819.7288
www.bsalifestructures.com
DESIGNEDDRAWNAPPROVEDBSALS PROJECT NO.
KEYPLAN
PLAN NORTH
DATE
D:\Users\DDurica\Documents\21730002-ARCH_BSALS_CENTRAL_v2018_DDurica.rvt10/23/2019 3:35:13 PM21730002
ApproverAuthorDesignerA501
WALL SECTIONS
10 -BED MEMORY CARE
HOME
STORY
COTTAGE
OCT 23, 2019
CLIENT PROJECT NO. - 21730002
1/4" = 1'-0" 1 TYP FRONT PORCH SECTION
1/4" = 1'-0"2 DETAIL AT PORCH COL BASE
1/4" = 1'-0"3 DETAIL AT PORCH COL COVER
1/4" = 1'-0"4 DORMER FRONT ELEVATION
1/4" = 1'-0" 5 DORMER SIDE ELEVATION
SCALE 3/4" = 1' -0"
SCALE 3/4" = 1'-0"
SCALE 3/4" = 1'-0"
SCALE 3/4 = 1'-0"
SCALE 3/4" = 1'-0"
MARK DATE DESCRIPTION
06/04/20
Mike Sheeks
TRUSS BRG. PT.
109'-1 1/8"
LEVEL 1-FF
100'-0"
BOT. FTG.
96'-4"
TRUSS BRG. PT.
110'-2 5/8"
BOT. FTG.
96'-4"
FOR TYPICAL
FASCIA NOTES
SEE SECTION 3/A8.2
COMPOSITE CROWN
MOULD GPM-165 (PAINT)
BEAM, PER STRUCT.
WOOD POST
W/ CONCRETE
FOOTING
PER STRUCT.
FCP PANELS WRAP
2x4 WD.FRAMING
SMOOTH FINISH FIBER CEMENT SOFFIT PANELS
SMOOTH FINISH FIBER CEMENT FASCIA (PAINT)
OVER 1/2" WOOD SHEATHING AT BEAM COVER
2x4 WOOD FRAMING
AT 16" O.C.
ENGINEERED PRE-FAB 2x
WOOD TRUSSES AT 24" O.C.
MIN. R-42 INSUL.
1/2" GYPSUM B.D.
ON VAPOUR BARRER
EXTEND VAPOUR BARRER
DOWN TO EXTERIOR CEILING
INTERIOR
SEE SECTION 3/A8.2
FOR TYPICAL NOTES 10'-2 5/8"7'-8"E
SOPE
8" A504
9 SIM.
7
A502
8
A5029'-1 1/8".1/2" GYPSUM BD.
ON VAPOUR BARRER
2x4 WOOD FRAMING AT 16" O.C.
R-13 KRAFT FACE BATT INSUL.
UPPER
STORAGE
1/2" GYPSUM BD.
WOOD BASE
3/4" T&G PLYWD.
2x10 WOOD FLOOR
JOIST AT 16" O.C.
1/2" GYPSUM BD.
KITCHEN/
TOILETS/
BEDROOMS/
ETC.
2x4 WD. FRAMING AT 16" O.C.
SOUND BATT INSUL.
1/2" GYPSUM BD.-EACH SIDE
WOOD BASE GPM-503 (PAINT)
4" CONC. SLAB
ON GRADE PER STRUCT.
ON VAPOUR BARRER
ON 12" PEA GRAVEL FILL
CONC. FOOTING,
MIN. R-42 ISULATION 9'-11 1/8"2 4
2 4
2 4
2 4
2 4
2 4
UPPER STORAGE LEVEL
109'-11 1/8"
LEVEL 1-FF
100'-0"
2 4
2 4
2 4
2 4
2 4
2 4
TRUSS BRG PT.
109'-1 1/8"
LEVEL 1-FF
100'-0"
BOT. FTG.
96'-4"
CONC. FOOTING,
R-10 RIDGE INSUL. AT FDN.
PERIMETER VERTICAL 2'-0" HIGH
4"CONC. SLAB ON GRADE ON
VAPOUR BARRER ON
12" PEA GRAVEL FILL
WOOD BASE GPM-503 (PAINT)
SILL SEALER
1/2" GYPSUM BD.
R-13 KRFT FACE BATT INSUL.
2x4 WOOD FRAING
AT 16" O.C.
WOOD TRIM CASING (PAINT)
APRON, JAMBS & HEAD
1x WOOD TRIM (PAINT)
AT PERIMETER SILL, JAMBS
& HEAD, TYP.
BUILT UP 2x WD. LINTEL, PER STRUCT.
R-13 KRFT FACE BATT INSUL.
1/2" GYPSUM BD.
ON VAPOUR BARRER
MIN. R-42 INSULATION
ATTIC AIR VENTILATION
BAFFLE
ENGINEERED PRE-FAB 2x
WOOD TRUSSES AT 24/" O.C.
ATTIC
12
VARIES
-SEE
ROOF
SLOPE
ASPHALT SHINGLES ON
ICE & WATER SHIELD
UNDERLAYMENT ON
5/8" EXTER. GR. PLYWD.
CONTINIOUS
SIFFIT VENT
12" COMPOSITE
FASICA TRIM (PAINT)
ON 2x WD. TRIM
PREFIN. SHT.
MTL. GUTTER
SMOOTH FINISH FIBER
CEMENT SOFFIT PANEL
4" COMPOSITE TRIM
WINDOW HEAD
FLASHING
4" COMPOSITE
WINDOW TRIM (PAINT)
PREFIN SHT. MTL.
DOWNSPOUT BEYOND
SINGLE HUNG VINYL
WINDOW W/
1/2" INSUL. GLASS
WINDOW SILL FLASHING
4" COMPOSITE
WINDOW TRIM (PAINT)
FIBER CEMENT PANEL
SIDING LAPPED ON
1" ZIP SYSTEM INSULATED
R-SHEATHING (R3.6)
PREFIN SHT. MTL.
FLASHING AT SILL
FINISH GRADE
SPLASH BLOCK
8" CMU FOOUNDATION
WALL GROUT SOLID9'-1 1/8" 6'-8 1/2"3'-8" 8"10"1'-1"
A504
1 SIM.
A504
9 SIM.2'-2". 4'-6 1/2" R.O.COMPOSITE
FASICA TRIM
SHT. MTL. FLASHING
RETURN ROOF
SHINGLES ON TO
EAVE RETURN
PREFIN. SHT. MTL.
GUTTER
COMPOSITE
FASICA TRIM
2'-0"
5
A502
TRUSS BRG. PT.
EL: 109'-1 1/8"
10" COMPOSITE TRIM
SHT. MTL. FLASHING
ASPHALT SHINGLES ON
ICE & WATER SHIELD
UNDERLAYMENT ON
5/8" EXTER. GR. PLYWD.
1x125 COMPOSITE
FASICA TRIM (PAINT)
ON 2x WD. BLOCKING
SOFFIT VENT
2x8 COMPOSITE TRIM
PROVIDE HOLES
FOR VENTILATION
AT SIDING
MIN. R-42
INSULATION
ATTIC
1'-1"
2 4
2 4 2 4
2 4
2424 24242424 2 42 4
FCP PANELS WRAP
2x4 WD. FRAMING
FCP PANELS WRAP
2x4 WD. FRAMING
WOOD POST
2x4 WOOD STUD
FRAMING 10 1/2"10 1/2" 9'-1 1/8"R-10 RIDGE INSUL. AT FDN.
PERIMETER VERTICAL 2'-0" HIGH
FLOOR FINISH-SEE SCHEDULE
4" CONC. SLAB ON GRADE
ON VAPOUR BARRIER
ON 12" PEA GRAVEL; FILL
WOOD BASE GPM-503 (PAINT)
1/2" GYPSUM BD.
SILL SEALER
R-13 KRAFT FACE BATT INSUL.
2x4 WOOD FRAMING
AT 16" O.C.
1/2" GYPSUM BD.
ON VAPOR BARRIER
MIN. R-12 INSULATION
ATTIC
ENGINEEERED PRE-FAB 2x
WOOD TRUSSES AT 24" O.C.
BRACING AT GABLE
END WALL FRAMING
RIDGE VENT,
SEE ROOF PLAN
ASPHALT SHINGLES ON
BLDG. FELT UNDERLAYMENT
ON 5/8" EXTER. GR. PLYWD.
TOP RIDGE
SEE ROOF PLAN
10" COMPOSITE FASCIA
TRIM (PAINT) ON 2x WD.
BLOCKING
4" COMPOSITE TRIM
FIBER CEMENT PANEL
SLIDING LAPPED ON
1" ZIP SYSTEM INSULATED
R-SHEATHING (R3.6)
EAVE RETURN
BEYOND
PREFINE. SHT. MTL.
FLASHING DRIP EDGE
FIBER CEMENT PANEL
SIDING LAPPED ON
1" ZIP SYSTEM INSULATED
R-SHEATHING (R-3.6)
WALL FLASHING
AT SILL
FINISH GRADE
8" CMU FOUNDATION
CONC. FOOTING,
TRUSS BRG. PT.
109'-1 1/8"
LEVEL 1-FF
100'-0"
BOT. FTG.
96'-4"9'-11 1/8"3'-8" 2 4
2 4
2 4
2 4
2 4
A504
9 SIM.
A504
5 SIM.
4
A502
BSA LifeStructures
9365 Counselors Row Suite 300
Indianapolis, IN 46240-1478
ph 317.819.7878 fx 317.819.7288
www.bsalifestructures.com
DESIGNEDDRAWNAPPROVEDBSALS PROJECT NO.
KEYPLAN
PLAN NORTH
DATE
D:\Users\DDurica\Documents\21730002-ARCH_BSALS_CENTRAL_v2018_DDurica.rvt10/23/2019 3:35:18 PM21730002
ApproverAuthorDesignerA502
WALL SECTIONS
10 -BED MEMORY CARE
HOME
STORY
COTTAGE
OCT 23, 2019
CLIENT PROJECT NO. - 21730002
1/4" = 1'-0"6 VERANDA WALL SECTION
1/4" = 1'-0" 2 BEARING WALL SECTION
1/4" = 1'-0" 3 TYP. WALL SECTION
1/4" = 1'-0"4 ELEV AT GABLE CORNICE
1/4" = 1'-0"5 DETAIL AT GABLE CORNICE
1/4" = 1'-0"8 DETAIL AT VERANDA COL.BASE
1/4" = 1'-0"7 DETAIL AT VERANDA COL.
1/4" = 1'-0" 1 TYP. GABLE ENDWALL SECTION
SCALE 1 1/2" = 1'-0"
SCALE 1" = 1' -0" SCALE 3/4" = 1'-0" SCALE 1" = 1'-0"
SCALE 3/4 = 1'-0"
SCALE 1 1/2" = 1'-0"
SCALE 1 1/2" = 1'-0"
SCALE 1 1/2" = 1'-0"
MARK DATE DESCRIPTION
06/04/20
Mike Sheeks
ATTIC
10'-2 5/8".ROUHG OPENING PER ENTRY DOOR/TRANSOM UNIT SELECTEDTRUSS BRG. PT.
110'-2 5/8"
STEEL ANGLE BRICK SHELF
WOOD ENTRY DOOR
TRANSOM W/ INSUL.
GLASS
SIX PANEL WOOD ENTRY
DOOR W/ WOOD
TRANSOM LITE & WOOD
SIDE LITE PANELS W/
INSUL. GLASS
ENTRY
DOOR
ELEVATION
4" CONC. PAD ON 4"
COMPACTED
GRANULAR BASE
INTERIOR
FOYER
MAIN
ENTRY
PORCH
1/2" GYPSUM BD.
ON VAPOR BARRIER
6" CMU COURSE
2
2
4
10 1/8".6'-8 1/2".4
2 4
MIN. R-42 INSUL.
ATTIC
ASPHALT SHINGLES ON
BLDG. FELT UNDERLAYMENT
ON 5/8" EXTER. GR. PLYWD.
10" COMPOSITE FASCIA
TRIM (PAINT) ON 2X WD.
BLOCKING
4" COMPOSITE
TRIM
FIBER CEMENT PANEL
SIDING LAPPED ON 1"
ZIP SYSTEM INSULATED
R-SHEATHING(R3.6)
STANDING SEAM SHEET
METAL PANEL ROOFING
ON ICE & WATER SHIELD
MEMBRANE ON RADIUS
ROOF PROFILE W/ BUILT-
UP WD. BLOCKING ON
1/2" WOOD SHEATHING
TRUSS BRG.PT.
109'-1 1/8"
1X6 COMPOSITE
TRIM (PAINT)
2X8 COMPOSITE
TRIM (PAINT)
SINGLE HUNG VINLY
WINDOW W/ APPLIED
MUNTINS AND 1/2"
INSUL. GLASS
INTERIOR
1/2" GYPSUM BD. ON
VAPOR BARRIER
BEAMS, PRE
STRUCT.
WINDOW SILL
FLASHING
LEVEL 1-FF
100'-0"
FINISHED GRADE
6" CMU COURSE
10" CMU FDN. WALL
GROUT SOILD W/
STEEL REINF.,
CONC.FOOTING
BOT FTG.
96'-4"3'-8". 7'-5 1/4". 5 1/2". 11 3/8"2'-2". 4'-6 1/2" R.O.9'-1 1/8".3 3/4".
BRK LEDGE
4".
9 5/8".
SEE SECTION 1 A8.1
FOR TYPICAL NOTES
2 4
2 4
2 42 4 2 4
2 4
2 4
2 4
1-1/2" CAVITY
1'-5 1/4".
10 1/8".
A504
5 SIM.
A504
7 SIM.
1'-1".
4" COMPOSITE FASCIA TRIM10".TRUSS BRG PT.
115'-8 9/16"
TRUSS BRG PT.
SEE ROOF
PLAN
FOR TYPICAL FASCIA NOTES
SEE SECTION 3 / A502
2 4
2 4
12
FIBER CEMENT PANEL
SIDING LAPPED ON 1"
ZIP SYSTEM INSULATED
R-SHEATHING (R3.6)
12
VERIES-
SEE
ROOF
SLOPE
ASPHALT SHINGLES ON ICE
& WATER SHIELD
UNDERLAYMENT ON 5/8"
EXTER. GR. PLYWD.
12" COMPOSITE FASCIA TRIM
(PAINT) ON 2X WD. BLOCKING
PREFIN SHT.MTL.
GUTTER
EVAE WORK PT
SEE ROOF PLAN
BEARING ELEV
110'-4 15/16"10".10'-2 5/8". CONTINUOUS
SOFFIT VENT
MATCH
SLOPE
OF
MAIN
ROOF
SMOOTH FINISH
FIBER CEMENT
SOFFIT PANEL
SINGLE HUNG VINYL
WINDOW W/ 1/2"
INSUL. GLASS
LEVEL 1 -FF
100'-0"
BOT. FTG.
96' -4"3'-8". 6".SEE SECTION 3 / A8.2
FOR TYPICAL NOTES
SILL SEALERFIXED WINDOW UNIT2'-3 1/4".4'-6 1/2" SINGLE HUNG 2'-2". WD. LINTEL,
PER STRUCT
2 4
2 4
2 4
2 4
2 4
ATTIC AIR
VENTILATION
BAFFLE
1/2" GYPSUM BD. ON
VAPOR BARRIER
BEAM, PER STRUCT.
MIN. R-42
INSUL.
ATTIC
INTERIOR
2 4
2 4
2 4
A504
8
A504
9 SIM.
LEVEL 1 -FF
SILL SEALER2 1/8"2 4
2 4
2 42 4
2 42 42 42 410".8".100'-0"
TRUSS BRG.PT.
109'-1 1/8"6'-8 1/2".3'-8". 9'-1 1/8".TOP R.O.
106'-8 1/2"2'-2". 4'-6 1/2" R.O.2X4 WD. STUDS
W/2X4 WD. CROSS
BRACE FRIMING
AT 16" O..C.
BOT.R.O. SILL
+102'-2"
SINGLE HUNG VINYL
WINDOW W/1/2"
INSUL. GLASS
8" CMU FOUNDTION
WALL GROUT SOILD
CONC. FOOTING
4" COMPOSITE TRIM
SOFFIT VENT
12" COMPOSITE TRIM
VENT HOLES THRU
SHEATHING
2XWD. BLOCKING
ASPHALT SHINGLES ON ICE &
WATER SHIELD UNDERLAYMENT
ON 5/8" EXTER. GR. PLYWD.
11-1/2". 1'-7".
EXTENDED 2xWD. TRUSS
FRAMING @ 24" O.C. (BOX
BAY W/ SOFFIT OVERHANG)
LINE OF FACE STUD
AT BOX BAY
12
VARIES-
SEE
ROOF
SLOPE
LINE OF TRUSS BEARING AT
MAIN WALL
ENGINEERED PRE-FAB
2XWOOD TRUSSES AT 24" O.C.
ATTIC AIR VENTILATION BAFFLE
MIN. R-42 INSUL.
1/2" GYPSUM BD. ON
VAPOR BARRIER
2XWD. TRUSS TOP CHORD
FRAMING EXTNSION @ 24"
O.C. ( BOX BAY)
BEAMS,PER STRUCT.
WD.LINTEL, PER STRUCT.
INTERIOR
FINISHED GRADE
A504
10 SIM.
A504
11 SIM.3' - 4 1/4"BRICK WORK
BRICK WORK
BSA LifeStructures
9365 Counselors Row Suite 300
Indianapolis, IN 46240-1478
ph 317.819.7878 fx 317.819.7288
www.bsalifestructures.com
DESIGNEDDRAWNAPPROVEDBSALS PROJECT NO.
KEYPLAN
PLAN NORTH
DATE
D:\Users\DDurica\Documents\21730002-ARCH_BSALS_CENTRAL_v2018_DDurica.rvt10/23/2019 3:35:22 PM21730002
ApproverAuthorDesignerA503
WALL SECTIONS
10 -BED MEMORY CARE
HOME
STORY
COTTAGE
OCT 23, 2019
CLIENT PROJECT NO. - 21730002
1 1/2" = 1'-0"1 ENTRY WALL SECTION
1 1/2" = 1'-0" 2 WINDOW SECTION
1 1/2" = 1'-0" 3 WINDOW SECTION BAY WDW / SIDE ELEV
1 1/2" = 1'-0" 4 WINDOW SECTION BOX BAY WDW / FRONT ELEV
SCALE 3/4" = 1' -0" SCALE 3/4" = 1'-0" SCALE 3/4" = 1'-0" SCALE 3/4" = 1'-0"
MARK DATE DESCRIPTION
06/04/20
Mike Sheeks
FINISH FLOOR
EL. 100'-0"
2 4
4" COMPACTED
GRANULAR BASE
4" CONCRETE PAD W/
REINF. MESH, PER STRUCT.8"VAPOR BARREIER12" PEA GRAVEL FILL
SLOPE CONCRETE SLAB W/ REINF. MESH,
STEEL REINF.
WOOD BASE-GPM-503 (PAINT)
CONTINIOUS SILL SEALER BENEATH 2x PLATE
3/8" DIA. A.B. SPACED PER STRUCT.
2x4 WOOD STUDS @ 16" O.C.
1/2" GYP. B.D.
8" CMU FOUNDATION WALL
GROUT SOLID W/ STEEL REINF.,
PER STRUCT.
R-10 RIDGE INSUL. AT FDN.
PERIMETER VERTICAL 2'-0" HIGH
EXTEND MTL. WALL FLASHING
TO HARD SURFACE BELLOW FOR CONC.
PADS, WALKS, HARDSCRAPES, ETC.
PREFIN. SHT. MTL WALL FLASHING
CONTINIOUS SEALANT BETWEEN
CMU FDN. & ZIP SHTHG.
FCP SIDING STARTER STRIP
SEAL TOP EDGE FLASHING W/
ZIP SYSTEM TAPE, PER MFR.
GUIDELINES
1" ZIP SYSTEM INSULATED
R-SHEATHING (R3.6)
FCP SIDING LAPPED
COLUMN BASE/ FIN.FLR.
EL: 100'-0"
2 4 2 4
SLOPE 8"8" CMU FOUNDATION WALL
GROUT SOLID
BRICK LEDGE
8" DEEP x5" WIDE
5"
GROUT CAVITY
SOLID FROM BRICK
LEDGE TO FIN. FLR.
LAWN
2x WD. STUD. FRAMING COLUMN BASE (4 SIDES) 2'-4"
THRU-WALL FLASHING W/ WEEPS AT 16" O.C.
CONCRETE PAD
4" COMPACTED
GRANULAR BASE
1/2" EXP. JOINT
W/ SEALANT ON
COMPRESSIBLE FILTER
2 4
2 4
2 4
2 42'-4"
COLUMN BASE/ FIN.FLR.
EL: 100'-0"7 1/4"3 7/8"
1'-11 1/4"
10" RADIUS
VENTED GFRC COLUMN COVER W/ TAPERED RADIUS
COLUMN,
MEMBRANE FLASHING AT CAP STONE
FOR COLUMN BASE
PRECAST CONCRETE CAP
W/ INTEGRAL DRIP EDGE
FACE BRICK VENEER W/ MASONARY TIES
1/2" EXTR. WD. SHEATHING
WARB (WEATHER RESISTANT BARRIER)
TOP RIDGE
EL: SEE EXTER.LEVELS.
ENGINEERED
PRE-FAB 2x
WOOD TRUSSES
AT 24" O.C.
GABLE END WALL
FRAMING
1" ZIP SYSTEM INSULTED
R-SHEATHING (R3.6)
FCP SIDING LAPPED
2x6 COMPOSITE FASICA
TRIM (PAINT)
1x8 COMPOSITE
FASICA TRIM
(PAINT)
ON 2x WD.
BLOCKING
PREFIN. SHT. MTL.
DRIP EDGE
ASPHALTSHINGLES
ON BLDG FELT UNDERLAYMENT
ON 5/8" EXTERIOR GR. PLYWD.
RIDGE, SEE ROOF PLAN
TRUSS BEARING PT.
EL: 110-2 5/8"
10 3/4" 10 3/4"42 42 4 2 42
DORMER WINDOW-
SINGLE HUNG VINYL WINDOW W/
"BLACKED OUT" SINGLE PANE GLAZING
1x4 COMPOSITE TRIM (PAINT)
PREFIN. SHT. MTL. FLASHING
ON 2x WD. CURB AT DORMER
DORMER SILL R.O.
EL: 113-8 5/8"
WD. HEADER AT
DORMER SILL, PER STRUCT.
ENGINEERED
PRE-FAB 2x
WOOD TRUSSES
AT 24" O.C.
ASPHALT SHINGLES ON
ICE & WATER SHIELD
UNDERLAYMENT
ON 5/8" EXTER. GR. PLYWD.
PREFIN. SHT. MTL. GUTTER
1x12 COMPOSITE FASICA (PAINT)
ON 2x12 WD. BLOCKING
COMTINUOUS SOFFIT VENT
SMOOTH FINISH FIBER CEMENT
SOFFIT PANELS (PAINT)
COMPOSITE CROWN MOULD
GPM-165 (PAINT)
SMOOTH FINISH FIBER CEMENT
FASICA & SOFFIT PANELS (PAINT ) OVER
1/2" WOOD SHEATHING AT BEAM COVER
COMPOSITE
CROWN MOULD
GPM-165 (PAINT)
BEAM, PER STRUCT.1'-4 3/8" 10"FINISH FLR.
2 4
2 4
2 42 49-1/2".1'-0". 4-1/2". 8". EL: 100'-0"
BRICK WORK
BOT.R.O. SILL
+102'-2"
PREFIN. SHT. MTL. FLASHING
SINGLE HUNG VINYL
WINDOW UNIT
8" CMU FOUNDTION
WALL GROUT SOILD
R-10 RIGID INSUL.AT FDN.
PERIMETER VERTICAL 2'-0"
HIGH
INTERIOR
FINISHED GRADE
CONTINUOUS SEALANT BETWEEN
CMU FDN. & ZIP SHTHG.
2X4 WD. STUDS W / 2X4 WD. CROSS
BRACE FRAMING AT 16" O.C.
2XWOOD FRAME
1'-4" (FIELD VERIFY)
PLAM SILL OR ALTERNATE FOR
WINDOW SEAT
WOOD WINDOW TRIM GPM-311
(PAINT)
1/2" GYP. BD.
R-13 KRAFT FACE
BATT INSUL.
1" ZIP SYSTEM INSULATED
R-SHEATHING (R3.6)
3/8" DIA. A.B. SPACED
CONTINUOUS SILL SEALER
BENEATH 2XPLATE
WOOD BASE-GPM-503 (PAINT)
STEEL REINF. DOWELS PER
STRUCT.
4" CONC. SLAB W/ REINF.
MESH.
VAPOR BARRIER
12" PEA GRAVEL FILL
BRICK WORK
TRUSS BRG. PT.
EL: 109'-1 1/8"
ENGINEERED
PRE-FAB 2x
WOOD TRUSSES
AT 24" O.C.
GABLE END WALL
FRAMING
MIN. R-42 INSUL.
VAPOR BARRIER
1/2" GYP. BD.
R-13 KRAFT FACE
BATT INSUL.
EAVE RETURN
BEYOND
FCP SIDING LAPPED
1" ZIP SYSTEM INSULATED
R-SHEATHING (R3.6)
COMPOSITE FASICA
TRIM BEYOND
1" ZIP SYSTEM INSULATED
R-SHEATHING (R3.6)
FCP SIDING LAPPED
A502
5
FINISH FLOOR
EL: 100'-0"
VAPOR BARRIER
12" PEA GRAVEL FILL
R-10 RIDGE INSUL. AT FDN.
PERIMETER VERTICAL 2'-0" HIGH
8" CMU FOUNDATION WALL
GROUT SOLID W/ STEEL REINF.,
PER STRUCT.
FINISH GRADE
EXTEND MTL. WALL FLASHING
TO HARD SURFACE BELLOW FOR CONC.
PADS, WALKS, HARDSCRAPES, ETC.MIN. GRADECLEARANCEPREFIN. SHT. MTL WALL FLASHING
CONTINIOUS SEALANT BETWEEN
CMU FDN. & ZIP SHTHG.
FCP SIDING STARTER STRIP
SEAL TOP EDGE FLASHING W/
ZIP SYSTEM TAPE, PER MFR.
GUIDELINES
1" ZIP SYSTEM INSULATED
R-SHEATHING (R3.6)
FCP SIDING LAPPED
4" CONCRETE SLAB W/ REINF. MESH PER STRUCT.
STEEL REINF. DOWELS PER STRUCT.
WOOD BASE-GPM-503 (PAINT)
CONTINUOUS SILL SEALER BENEATH 2x PLATE
3/8" DIA. A.B. SPACED PER STRUCT.
2x4 WOOD STUDS @ 16" O.C.
1/2" GYP. BD.
R-13 KRAFT FACE BATT INSUL.
12
FCP SIDING LAPPED ON WRD ON 1/2" EXTER.
WD. SHEATHING, SEE TYPICAL DETAILS ON
A8.22.
ASPHALT SHINGLES ON ICE &
WATER SHIELD UNDERLAYMENT
ON 5/8" EXTER. GR. PLYWD.
1X12 COMPOSITE FASCIA(PAINT)
ON 2X12 WD. BLOCKING
PREFIN SHT.MTL. GUTTER
TRUSS BRG.PT.
EL: 115'-8 9/16"10".CONTINUOUS SOFFIT VENT
VARIES, SEE
ROOF PLAN
1/4" SMOOTH FINISH FIBER CEMENT
SOFFIT PANELS (PAINT)
R-13 KRAFT FACE BATT
INSUL.
2 4
2 4
2 4
2 4
2 4
ATTIC AIR
VENTILATION BAFFLE
1/2" GYP. BD
BEAM, PER STRUCT.
VAPOR BARRIER
MIN. R-42 INSUL.
ENGINEERED PRE-FAB
2XWOOD TRUSSES AT
24" O.C. ATTIC AIR
VENTILATION BAFFLE
WOOD WINDOW TRIM
GPM-311(PAINT)
LINTELS, PER STRUCT.
FCP SIDING LAPPED
1" ZIP SYSTEM INSULATED
R-SHEATHING (R3.6)
2X4 COMPOSITE TRIM
(PAINT)
WINDOW HEAD FLASHING
TOP R.O. +108'-11 3/4"
FIXED WINDOW UNIT
OVER SINGLE HUNG
WINDOW
TOP SINGLE HUNG WINDOW UNIT
+106'-8 1/2"
2 42 42 42 4
TRUSS BRG.PT.
109'-1 1/8"
TOP R.O.
106'-8 1/2"
1/4" SMOOTH FINISH FIBER CEMENT
FASCIA & SOFFIT PANELS (PAINT)
2XWD. BLOCKING
ASPHALT SHINGLES ON ICE &
WATER SHIELD UNDERLAYMENT
ON 5/8" EXTER. GR. PLYWD.
11-1/2". 1'-7".
EXTENDED 2xWD. TRUSS
FRAMING @ 24" O.C. (BOX
BAY W/ SOFFIT OVERHANG)
LINE OF FACE STUD
AT BOX BAY
LINE OF WD.
TRUSS BEARING
ENGINEERED PRE-FAB
2XWOOD TRUSSES AT 24" O.C.
ATTIC AIR VENTILATION BAFFLE
MIN. R-42 INSUL.
1/2" GYP. BD.
BEAMS,PER STRUCT.
LINTELS, PER STRCUT.
INTERIOR
SINGLE HUNG VINYL WINDOW UNIT
2X4 COMPOSITE TRIM (PAINT)
PREFIN. SHT. MTL. FLASHING
COMPOSITE FASCIA
(PAINT) ON 2X12 WD.
BLOCKING
2X4 TOP CHORD
EXTENSION @ 24" O.C.
VAPOR BARRIER.
1/2" GYP. BD.
R-13 KRAFT FACE
BATT INSUL.
2X4WD. STUDS AT
16" O.C.
WOOD WINDOW TRIM
GPM-311 (PAINT)
MIN. R-42 INSUL.
TRUSS BRG.PT.
109'-1 1/8"
1X COMPOSITE
FASCIA & SOFFIT PANEL(PAINT)
2X8 COMPOSITE
TRIM (PAINT)
1/2" GYP. BD.
R-13 KRAFT FACE
BATT INSUL.5 1/2". 1'-9 7/8".2 4
2 4
2 42 42 4
1/2" GYP. BD.
LINTELS,
R-13 KRAFT FACE
BATT INSUL.
VAPOR BARRIER
GABLE ENDWALL.
FRAMING
ENGINEERED
PRE-FAB 2X
WOOD
TRUSSES AT 24"
O.C.
COMPOSITE FASCIA
TRIM BEYOND
FCP SIDING LAPPED
1" ZIP SYSTEM INSULATED R-SHEATHING
(R3.6)
SEAL TOP EDGE FLASHING W/ ZIP
SYSTEM TAPE, PER MFR GUIDELINES
PREFIN. SHT. MTL. "Z" FLASH AT TOP MTL
PANELS, SECURE BEHIND SIDING
PREFIN. STANDING SEAM SHT. MTL,
PANELS, ROOFING ON ICE & WATER SHIELD
UNDERLAYMENT ON RADIUS ROOF
PROFILE W/ BUILT-UP WD. BLOCKING ON
1/2" EXTER. WD. SHEATHING
1'-6 1/2".
SEE WINDOW
SCHEDULE
WIN. HEAD R.O.
EL: 106'-8 1/2"1'-8".8 5/8". FRMG. BRG.. PT
BSA LifeStructures
9365 Counselors Row Suite 300
Indianapolis, IN 46240-1478
ph 317.819.7878 fx 317.819.7288
www.bsalifestructures.com
DESIGNEDDRAWNAPPROVEDBSALS PROJECT NO.
KEYPLAN
PLAN NORTH
DATE
D:\Users\DDurica\Documents\21730002-ARCH_BSALS_CENTRAL_v2018_DDurica.rvt10/23/2019 3:35:23 PM21730002
ApproverAuthorDesignerA504
WALL DETAILS
10 -BED MEMORY CARE
HOME
STORY
COTTAGE
OCT 23, 2019
CLIENT PROJECT NO. - 21730002
1/2" = 1'-0"4 FRONT PORCH WALL AT GRADE
1/2" = 1'-0"3 FRONT PORCH COLUMN BASE AT GRADE
1/2" = 1'-0"2 FRONT PORCH COLUMN AT CONC. CAP
1/2" = 1'-0"5 TOP RIDGE AT GABLE END
1/2" = 1'-0" 1 FRONT PORCH EAVE
1 1/2" = 1'-0"11 WINDOW SILL AT BOX BAY WINDOW
1/2" = 1'-0" 6 SECTION AT GABLE CORNICE
1/2" = 1'-0"9 SILL SECTION AT SIDING
1 1/2" = 1'-0"8 WINDOW HEAD @ BAY WINDOW
1 1/2" = 1'-0"10 WINDOW HEAD AT BOX BAY WINDOW
1 1/2" = 1'-0" 7 HEAD SLOPED MTL. PANEL ROOFING
SCALE 1 1/2" = 1'-0"
SCALE 1 1/2" = 1'-0"
SCALE 1 1/2" = 1'-0"
SCALE 1 1/2" = 1'-0"
SCALE 1 1/2" = 1'-0"
SCALE 1 1/2" = 1'-0"
SCALE 1 1/2" = 1'-0"
MARK DATE DESCRIPTION
06/04/20
Mike Sheeks
5' - 6"7' - 4"3' - 0"FABRIC WRAPPED ACOUSTICAL
PANEL
10' -0"
PAINTED WOOD TRIM -
COVER PANEL
ATTACHMENT HARDWARE
CEILING
GYPSUM WALL BOARD
J-MOLD TRIM AT PERIMETER
SPLINE CLIP
2' - 3" 2' - 6" 2' - 3"
FABRIC WRAPPED
ACOUSTICAL
PANEL- PAINTED
WOOD TRIM AT
PERIMETER SIMILAR
TO 6/A600107
1' - 4" 2' - 0" 2' - 2" 3' - 3" 2' - 6" 2' - 6"
LOCKABLE MINI -FRIDGE5' - 5" 1' - 4"123A
GROUND
100' - 0"
MEZZANINE
109' - 11 1/8"1 1/2"9 1/4"9 1/4"8' - 0"1' - 2 1/4"
FABRIC WRAPPED ACOUSTICAL
PANEL
10' -0"
CEILING
GYPSUM WALL BOARD
PROVIDE FINISHED OPENING IN PANEL
TO ACCOMODATE ELECTRICAL
BOX/TRIM (APPROXIMATELY 2" LARGER
THAN FIXTURE COVER PLATE ON ALL
SIDES, COORDINATE WITH CARPENTER
FOR EXTENT OF TRIM)
ELECTRICAL BOX -OFFSET 1 5/8"
FROM FACE OF STUD
1 5/8"ELECTRICAL BOX -OFFSET 1 5/8"
FROM FACE OF STUD
FIXTURE -FOR REFERENCE ONLY
2"
PAINTED WOOD TRIM -COVER PANEL
ATTACHMENT HARDWARE
FABRIC WRAPPED ACOUSTICAL
PANEL
PROVIDE FINISHED OPENING IN
PANEL TO ACCOMODATE
ELECTRICAL BOX -SCONCE BASE
PLATE TO COVER OPENING IN PANEL
ELECTRICAL BOX -OFFSET 1 5/8"
FROM FACE OF STUD
GYPSUM WALL BOARD
SCONCE -FOR REFERENCE ONLY
1 5/8"
BSA LifeStructures
9365 Counselors Row Suite 300
Indianapolis, IN 46240-1478
ph 317.819.7878 fx 317.819.7288
www.bsalifestructures.com
DESIGNEDDRAWNAPPROVEDBSALS PROJECT NO.
KEYPLAN
PLAN NORTH
DATE
D:\Users\DDurica\Documents\21730002-ARCH_BSALS_CENTRAL_v2018_DDurica.rvt10/23/2019 3:35:27 PM21730002
ApproverAuthorDesignerA600
DETAILS AND INTERIOR
ELEVATIONS
10 -BED MEMORY CARE
HOME
STORY
COTTAGE
OCT 23, 2019
CLIENT PROJECT NO. - 21730002
1/4" = 1'-0" 1 ARCHED OPENING
1" = 1'-0"6 ACOUSTICAL PANEL DETAIL
1/4" = 1'-0"2 SOUND PANEL ABOVE CABINETS
1/4" = 1'-0"3 LIBRARY CASEWORK
1/4" = 1'-0"4 TYP. BEDROOM CLOSET
1/4" = 1'-0"5 LATTICE PERGOLA
MARK DATE DESCRIPTION
12" = 1'-0"7 FLOORING TRANSITION
1" = 1'-0" 8 ACOUSTICAL BULKHEAD DETAIL - SECTION
1" = 1'-0"9 ACOUSTICAL BULKHEAD DETAIL - SECTION
06/04/20
Mike Sheeks