Loading...
HomeMy WebLinkAboutStoryCottage Floor Layout_1902609Ea_LOIndianapolis Design Center352 South County Road 300 EDanville, IN  46122317-745-9984These placement plans have been prepared with the specifications of TrussJoist products based on project information provided. This service is solely intendedfor product application assurance; and, is not intended to circumvent the needfor a design professional as determined by the building codes. The designerof record and/or builder/framer is responsible to assure these drawings arecompatible with the overall project. These documents are not intended to replacethe building plan (which should be used to determine bearing placement).Please insure measurements of the foundation match those provided at the timeof design.  Builder is responsible to place load bearing members in load path.Architectural Drawings Prepared By: Structural Drawings Prepared By: 84 Lumber FranklinKevin BeherStory Custom DevelopmentStory CottageRev.aBy Date CM 11/14/2019CommentsAdded bearing for beam and stairholeDrawn By:CMChecked By: Date:11/1/20191902609Ea Sheet 1 of 1 Second Floor System Not to Scale All Dimensions are Approximate and Must Be Field Verified. 11 7/8" TJI Joists 16" o.c. spacingFraming Connector Summary PlotID Qty Manuf Product Design Method Face Nails Top Nails Member Nails Skew Slope Backer Blks Filler Web Stiff H1 1 Simpson HHUS5.50/10 Designed 30- 10d - 10- 10d - - No No No H2 40 Simpson IUS1.81/11.88 Designed 10- 10d - 2- Strong-Grip - - No No No Products PlotID Length Product Plies Net Qty FJ1 14' 0" 11 7/8" TJI 110 joist 1 31 FJ2 10' 0" 11 7/8" TJI 110 joist 1 15 FJ3 6' 0" 11 7/8" TJI 110 joist 1 2 BM1 26' 0" 1 3/4" x 11 7/8" 2.0E Microllam LVL 2 2 Pt1 12' 0" 3 1/2" x 5 1/4" 1.8E Parallam PSL 1 1 BM2 22' 0" 1 3/4" x 11 7/8" 1.55E TimberStrand LSL 3 3 BM3 14' 0" 1 3/4" x 11 7/8" 1.55E TimberStrand LSL 2 4 BM4 8' 0" 1 3/4" x 11 7/8" 1.55E TimberStrand LSL 2 2 Ca1 16' 0" 1 1/8" x 11 7/8" TJ Rim Board 1 6  LEVEL NOTES  Current Date:  11/14/2019  File Name:  1902609Ea.jvl  Level Name:  First FLoor System  Building Code - Design Methodology:  IBC 2006  Members with Design Overridden:  TJ-Pro Rating (Weighted Average):  59     Minimum Level TJ - Pro Rating & Joist:  TJ-Pro rating = 56, joist = FJ1(i1523)     Maximum Level TJ - Pro Rating & Joist:  TJ-Pro rating = 67, joist = FJ2(i1528)  FLOOR  Floor Container:  FC2  Use/Occupancy:  ResidentialLivingAreas  Floor Area Loading is:  40.0 lb/ft² Live Load & 10.0 lb/ft² Dead Load  Maximum Allowed Deflection:  L/480 Live Load & L/240 Total Load  TJ-Pro Rating Information:      Weighted Average:  59      Directly Applied Ceiling:  Gypsum 1/2"      Decking Attachment:  Glue and Nail      Decking Material:  23/32"x48"x96" Weyerhaeuser Edge Panel (0/24) T&G FF      Perpendicular Partition:  No      Strapping at max 8' o.c.:  None      Blocking at max 8' o.c.:  No      Poured Flooring:  No A3 A3 A3 A3 A3 A3 BM3 BM1 BM4 FJ1 FJ1 FJ1 FJ1 FJ1 FJ1 FJ1 FJ1 FJ1 FJ1 FJ1 FJ1 FJ1 FJ1 FJ1 FJ1 FJ1 FJ1 FJ1 FJ1 FJ1 FJ1 FJ1 FJ2 FJ2 FJ2 FJ2 FJ2 FJ2 FJ2 FJ2 FJ2 FJ2 FJ2 FJ2 FJ2 FJ2 FJ1 FJ1 FJ1 FJ1 FJ1 FJ1 FJ1 FJ1 Ca1Ca1 Ca1 Ca1Ca1 Ca1 Ca1BM3 BM2FJ3H2 FJ3H2FJ2 H2 H2 H2 H2 H2 H2 H2H2 H2H2 H2H2 H2H2 H2H2 H2H2 H2H2 H2H2 H2H2 H2H2 H2H2 H2H2 H2H2 H2H2 H2H2 H2H2 Pt1 H1Confirm footer below. 06/04/20 Mike Sheeks