Loading...
HomeMy WebLinkAboutGrading Plan - C300 KinderCare Carmel15' SETBACK20' SETBACK30' SETBACK KIDERCARE LEARNING CENTER SINGLE STORY BUILDING “6) F.F. 902.00' SOUTH SUB-PARCEL (58110 SF OR 1.33 AC) NORTH SUB-PARCEL (49960 SF OR 1.15 AC) 20' SE T B A C K 11 12 12 0' 5' 10' 15' 20' 25' 50' OFFSET BRELLA20' SETBACK30' SETBACK ANDGREENBELT12 901.18' 1.00% 901.41' T/P 900.98' T/P 901.91' B/C 901.84' T/C 901.60' T/C 901.72' T/C 901.84' T/C 901.84' T/C 901.95' T/C 901.60' T/C 901.84' T/C 900.58' T/P 901.08' B/C 901.63' T/P MATCH EXST 899.59' T/P MATCH EXST 899.55' T/P MATCH EXST 899.51' T/P 900.65' T/P 900.00' T/P 900.33' T/P 900.64' T/P 901.14' B/C 900.63' T/P 899.75' T/P 900.04' T/P 900.25' B/C 901.02' T/C 900.52' T/C 900.35' T/C 900.23' T/C 901.13' B/C @ DR STOOP TYP. 901.96' T/C 901.75' T/C 20'-0" SAN. EASEMENT 20'-0" WATER E A S E M E N T NO PLAN T I N G SUB-PARCEL LINE 20'-0" SAN. EASEMENT 10'-0" GAS EASEMENT 10'-0" GAS EASEMENT DISTURBANCE LIMIT 901.80' T/C 901.18' T/P 901.20' T/P 901.91' B/C 900.50' T/P 900.94' B/C 900.42' RIM 901.18' T/P 901.68' B/C 902.13' B/C 900.79' T/P 901.68' B/C 901.18' T/P 901.68' B/C 901.80' T/C 901.84' T/C 901.70' T/C 900.90' T/P 901.10' T/P 901.60' B/C 2.76% 900.64' T/P 901.24' T/C 900.50' T/C 901.15' B/C 900.40' T/C 900.72' B/C 901.80' T/C 901.96' T/C 901.68' T/C MATCH EXST 899.66' T/P 1.20% B/EXC 900.38' 901.30' B/EXC 900.14'' 901.06' B/EXC 900.30' 901.22' B/EXC 900.76' 901.68' B/EXC 900.35' 901.27' B/EXC 900.82' 901.74' B/EXC 900.87' 901.79' B/EXC 900.51' 901.43' EX. INLET 900.33' B/C MATCH EXISTING SIDEWALK MATCH EXISTING SIDEWALK 900.26' RIM 896.20' INV 901.40' RIM 900.54' B/C 900.90' B/C 901.5'901.5'901.25' 901.52' 901.42' 900.0' 898.0' 897.0' 1:4 MAX. SLOPE OUTSIDE PARKING 1:4 MAX. SLOPE SOUTH OF FENCE 900.0' 900.93' B/C 901.0'901.5'898.0' DISTURBANCE LIMI T DISTURBANCE LIM I T DISTURBANCE LIMITDISTURBANCE LIMIT DISTURBANCE LIMIT901.27' B/C 901.18' T/P 901.18' T/P 901.68' B/C 901.68' B/C 1.00%900.73' T/P 900.65' RIM 2.06% 901.23' B/C 1.50%1.37%1.50%1.00%901.18' T/P 1.25% 900.85' T/P 901.35' B/C 1.00% 900.96' T/C 899.85' RIM 1.30% 900.21' T/P 900.46' T/P 901.68' B/C 900.78' T/P 900.53' T/P 1.00%1.00%1.30% 901.06' T/P 900.77' T/P 900.40 T/P 900.85' B/C 901.56' B/C 2.00% SLOPE TO THE ROAD ADA ZONE 900.71' T/C 1.00%1.00%1.41%1.00% 899.57' RIM CURB TURNOUT DISCHARGE, SEE 3/C703 1.20%2.00%2.00%2.00%H.P.H.P.H.P.H.P. 900.65' T/P 1.00% 900.61' T/P 900.69' T/P 3.00% 900.75' T/P 899.85' T/P 900.65' T/P 1.00% 900.53' T/P 1.00% 900.50' 901.0'900.5'9 0 0 . 5 '900.0'900.0' 900.0' 899.0' 899.0' 899.0' 898.0' 897.0'901.0'1:4 MAX. SLOPE OUTSIDE PARKING 897.0' 901.61' 898.0' 901.03' T/P 1.00% 901.08' T/P 899.08' T/P 900.53' T/P5.00%898.96' T/P 899.21' T/P 900.41' T/P 900.91' B/C 900.66' T/P 901.16' B/C 900.91' T/P 901.25' T/P 901.37' T/P 901.87' T/P898.0'MATCH EX. 903.21' T/C 902.71' T/C 1.82% 902.0' 902.0' 901.0' 900.0'; 899.0' 901.0' 900.0' 899.0' 901.0' 900.0' LOW 899.50' LOW 899.25' LOW 898.50' LOW 898.00' LOW 897.50' TOTAL DISTURBANCE AREA = 1.729 ac CURB TURNOUT DISCHARGE, SEE 3/C703 2.0% CROSS SLOPE SOUTH LOCAL (BLDG FRONT DITCH) FLOOD ELEV. = 900.00' MIN. FLOOD PROTECTION GRADE = 902.00' LOWEST ADJACENT GRADE = 901.60' GRADING NOTES: 1.EXISTING GRADES AND IMPROVEMENTS SHOWN ARE BASED ON THE MOST ACCURATE INFORMATION AVAILABLE. ALL INFORMATION MUST BE VERIFIED IN THE FIELD BY THE CONTRACTOR PRIOR TO THE START OF CONSTRUCTION. ANY DISCREPANCIES SHALL BE IMMEDIATELY REPORTED TO THE ENGINEER. 2.EXISTING UNDERGROUND UTILITIES SUCH AS WATER, SANITARY, STORM, GAS, ELECTRIC, ETC. AS SHOWN ON THE PLANS HAVE BEEN DETERMINED FROM THE MOST ACCURATE INFORMATION AVAILABLE. ALL INFORMATION MUST BE VERIFIED IN THE FIELD BY THE CONTRACTOR PRIOR TO THE START OF CONSTRUCTION. ANY DISCREPANCIES SHALL BE IMMEDIATELY REPORTED TO THE ENGINEER. THE INFORMATION IS GIVEN FOR THE CONVENIENCE OF THE CONTRACTOR. THE OWNER AND ENGINEER DO NOT ASSUME RESPONSIBILITY OF THE ACCURACY OF THE LOCATIONS SHOWN. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO CONTACT ALL UTILITY COMPANIES AND THEIR FACILITIES SHALL BE LOCATED PRIOR TO ANY WORK. 3.BEFORE STARTING ANY CONSTRUCTION, THE CONTRACTOR SHALL EXPOSE ANY UTILITIES OR OTHER OBSTRUCTIONS TO BE CROSSED BY THE PROPOSED SEWER AND SHALL NOTIFY THE ENGINEER IMMEDIATELY IF THERE ARE ANY CONFLICTS WITH THE PROPOSED SEWER GRADE. 4.CALL J.U.L.I.E. (1-800-892-0123) PRIOR TO ANY AND ALL DIGGING. 5.THE CONTRACTOR SHALL BE RESPONSIBLE TO CONNECT OR RE-ROUTE ANY EXISTING UNDERGROUND SANITARY OR STORM SEWERS ENCOUNTERED, NOT INDICATED ON THE PLANS WHETHER ACTIVE OR NOT DURING CONSTRUCTION AS NECESSARY. 6.ALL AFFECTED OFF-SITE AREAS SHALL BE RESTORED WITHIN TWO WEEKS OF DISTURBANCE. 7.ANY WORK WITHIN THE INDOT ROW SHALL BE CONDUCTED IN ACCORDANCE WITH INDOT SPECIFICATIONS. 8.ALL GRADES ARE FINISHED GRADE ELEVATIONS. 9.ALL ELEVATIONS ARE TO GUTTER GRADE UNLESS NOTED OTHERWISE. 10.ALL OPEN SPACE AREAS SHALL BE DRESSED WITH TOPSOIL AND SEEDED OR SODDED PER THE CONTRACT. MAXIMUM SIDE-SLOPE IN OPEN SPACE AREAS SHALL BE 4H TO 1V. 11.THE CONTRACTOR SHALL MAINTAIN PUBLIC ROADWAYS CLEAN OF ANY AND ALL MATERIALS AND DEBRIS WHICH RESULT FROM CONSTRUCTION OPERATIONS. 12.THE CONTRACTOR SHALL REVIEW AND UNDERSTAND THE GEOTECHNICAL INVESTIGATION REPORT AND ITS EFFECT ON THE CONSTRUCTION OF THE PROPOSED SITE IMPROVEMENTS. THE CONTRACTOR SHALL ADVISE THE OWNER AND ENGINEER OF ANY POTENTIAL ADJUSTMENTS TO THE GRADING PLAN. 13.STRIP 6" MINIMUM TOP SOIL FROM ALL AREAS WHICH WILL BE FILLED OR CUT INCLUDING WASTE OR BORROW AREAS. ADDITIONAL STRIPPING MAY BE REQUIRED TO ENSURE REMOVAL OF ORGANICS AND SOFT SEDIMENTS. 14.AREAS WHICH WILL RECEIVE EMBANKMENT SHALL HAVE TOP 12-INCHES DISKED AND COMPACTED TO 95% STANDARD PROCTOR DENSITY. 15.ALL FILL MUST BE COMPACTED TO A DENSITY NOT LESS THAN 95% STANDARD PROCTOR DENSITY WITH MOISTURE LIMITS SET FORTH IN SOILS REPORT. 16.ALL LOCALIZED AREAS WHICH CANNOT BE COMPACTED OR WHICH SHOW EVIDENCE OF PUMPING ACTION MUST BE UNDERCUT AND RECOMPACTED WITH ON-SITE FILL MATERIAL. 17.ALL STRUCTURAL FILL AREAS SHALL BE BENCHED. 18.MAINTAIN CUT AND FILL AREAS TO ACCOMMODATE SURFACE DRAINAGE. 19.STOCKPILE TOP SOIL FOR SHOULDERING AND SEED/SOD BEDS. 20.FINISHED GRADE TOLERANCE IS 0.20 FOOT FOR NON-PAVED AREAS. 21.FINISHED GRADE TOLERANCE IS 0.10 FOOT FOR PAVED AREAS. 22.MINIMUM THICKNESS OF TOP SOIL IS 6-INCHES ON ALL LANDSCAPE AREAS. 23.BACKFILL TO TOP OF ALL CURBS. 24.THE PROJECT SITE IS PRIVATE OWNED, THE GRADING SYSTEM IS DESIGNED FOR PRIVATE USE. 25.NO EARTH DISTURBING ACTIVITY MAY COMMENCE WITHOUT AN APPROVED STORM WATER MANAGEMENT PERMIT. 26.DAMAGE TO THE EXISITNG RIGHT-OF-WAY SHALL BE RESTORED/REPAIRED TO THE SATISFACTION OF THE CITY AT THE COMPLETION OF THE PROJECT. THE CONTRACTOR IS ENCOURAGED TO INSPECT THE RIGHT-OF-WAY WITH THE CITY PRIOR TO THE START OF CONSTRUCTION TO DOCUMENT THE EXISTING CONDITION OF THE RIGHT-OF-WAY. 27.ALL PAVING WITHIN THE EXISTING AND PROPOSED CITY RIGHT -OF-WAY SHALL CONFORM TO THE REQUIREMENTS OF THE DEPARTMENT OF ENGINEERING. THE CONTRACTOR SHALL CONTACT THE DEPARTMENT OF ENGINEERING TO SCHEDULE A PRE-CONSTRUCTION MEETING TO REVIEW THE DEPARTMENT'S CONSTRUCTION REQUIREMENTS, STAFF NOTIFICATION REQUIREMENTS, REQUIRED INSPECTIONS FOR CERTAIN STAGES OF THE WORK AND TO REVIEW THE AUTHORITY OF THE DEPARTMENT AS IT RELATES TO WORK WITHIN THE EXISTING AND PROPOSED RIGHT-OF-WAY. 1 2 3 4 5 6 1 2 3 4 5 6 D C B A 236 EAST MAIN STREETENGINEERING THAT WORKSENGINEERING WITH STYLEGAS CITY, IN 46933SCALE(36x24): SITE GRADING PLAN C300 1 1" = 20' - 0" GRADING PLAN C300 N GRADING POINT ELEV. LEGEND: T/P TOP OF PAVING ELEV. T/C TOP OF CONCRETE B/C BACK OF CURB ELEV. EX EXISTING ELEV. INV.INV. ELEV. OF PIPE RIM RIM ELEV. B/EXC B/O EXCAVATION GRADING CONTOUR LEGEND: XXX'NEW CONTOUR XXX'EXISTING CONTOUR GRADING REF. NOTES: 1. SURVEY'S ORIGINAL BENCHMARK ESTABLISHED WITH TRIMBLE GPS SURVEY GRADE EQUIPMENT AND INDIANA CORS NETWORK. 2. ELEVATION REF. TO NORTH AMERICAN VERTICAL DATUM (NAVD) 1988. 3, HORIZONTAL REF. INDIANA STATE PLANE EAST ZONE, NW COR OF SW 1 4 OF S6-T17N-R3E, HARRISON FOUND.