Loading...
HomeMy WebLinkAboutUtility Plan - C400 KinderCare Carmel15' SETBACK20' SETBACK30' SETBACK KIDERCARE LEARNING CENTER SINGLE STORY BUILDING “6) F.F. 902.00' SOUTH SUB-PARCEL (58110 SF OR 1.33 AC) NORTH SUB-PARCEL (49960 SF OR 1.15 AC) 20' SE T B A C K 11 12 12 0' 5' 10' 15' 20' 25' 50' OFFSET BRELLA20' SETBACK30' SETBACK ANDGREENBELT12 EX.ST EX.ST EX.ST EX.ST EX.ST EX.ST EX.ST EX.STEX.GASEX.GASEX.GASEX.GASEX.GASEX.GASEX.GASEX.GASEX.GASEX.GASEX.GASEX.GASEX.GASEX.GASEX.GASEX.GASEX.GASEX.GASEX.GASEX.GASEX.GASEX.GASEX.GASEX.GASEX.GASEX.GASEX.GASEX.SANEX.SANEX.SANEX.SANEX.SANEX.SANEX.SANEX.SANEX.SANEX.SANEX.SANEX.SANEX.SANEX.SANEX.SANEX.SANEX.SANEX.SANEX.SANEX.SANEX.SANEX.SANEX.SANEX.SANEX.SAN CWCWCWCWCWCWCWCWCWCWCWCWCWCWCWCWCWCWCWCWCWCWCWCWCWCWCWCWCWCWCWCWCWCWCWCWCWCWCWCWCWCWCWCWCWCWCWCWCWCWCWCWCWCWCWCWCWCWCWCWCWCWCWCWCWCWCWCWCWCWCWCWCWCWCW20'-0" SAN. EASEMENT 20'-0" WATER E A S E M E N T NO PLAN T I N G SUB-PARCEL LINE SAN SAN ‘39&6$1678%)251257+68%3$5&(/ CAP END AND MARK INV. 894.00' 20'-0" SAN. EASEMENT 10'-0" GAS EASEMENT WTR GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GASGASGASGASSTSTSTSTSTSTSTSTSTSTSTSTSTST ST‘:$7(572%8,/',1* STOP IN BOX PER CITY OF CARMEL; RIM EL.= 898.50' B/O BOX EL.= 894.83' 352326('‘:$7(57$3 72(;,67,1*‘0$,1 V.I.F. FOR INV. EL. CONNECT TO THE METER BOX PROPOSED TRANSFORMER (2) 4" SECONDARY (2) 2" PRIMARY TO SOURCE PAD T/C EL. 901.25' GAS TO SERVES INV. EL. /)‘39&6$1/$7(5$/ @ 1.00% SLOPE (;7(1'(;,67,1*‘/$7(5$/678% FOR 25 LF PVC @ 1.00% SLOPE TO S.MH. 101 EXISTING SAN. LATERAL STUB INV. EL. = 893.23' S. MH. 101 3'-0" ‘6$17<3(,,&2 w/ LOCKABLE CAP RIM EL. = 901.90' INV. EL.= 896.21' ‘39&6$17,(72%/'*6$1 @ 1.00% SLOPE; INV. EL. = 896.24' STSTSTSTST STSTSTSTST CB. 101 ROOF DRAIN DISCHARGE TO GRADE PIPE #1 /)‘+'3(&3367250 @ 0.33% SLOPE PIPE #2 /)‘+'3(&3367250 @ 0.40% SLOPE EX. CB. ROOF DRAIN DISCHARGE TO GRADEROOF DRAIN w/ UNDERGROUND PIPE DAYLIGHT AT CURB FACE ROOF DRAIN w/ UNDERGROUND PIPE DAYLIGHT AT CURB FACE ROOF DRAIN w/ UNDERGROUND PIPE DAYLIGHT OUTSIDE FENCE‘&21'(16(5'5$,1 TIE TO THE DOWNSPOUT ‘&21'(16(5'5$,1 TIE TO THE DOWNSPOUT 10'-0" GAS EASEMENT CONNECT GAS TO EXISTING GAS SERVICE w/ VECTREN DISTURBANCE LIMIT CB. 103 ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST STSTSTSTSTSTSTCB. 104 STSTPIPE #5 /)‘+'3(&3367250 @ 0.33% SLOPE /)‘39&5' @ 2.0% SLOPE /)‘39&5' @ 2.0% SLOPE ‘39&5' @ 2.0% SLOPE END SECTION, SEE 4/C703 w/ ANIMAL & DEBRIS GUARD INV. EL. = 897.25' PIPE #3 /)‘+'3(&3367250 @ 0.26% SLOPE UTILITY CROSSING ‘6$1,19= 893.64' ‘67,19= 896.48' UTILITY CROSSING ‘6$1,19= 893.37' ‘67,19= 896.43' UTILITY CROSSING ‘6$1,19= 892.96' ‘67,19= 896.28' DISTURBANCE LIM I T DISTURBANCE LIM I T DISTURBANCE LIMITDISTURBANCE LIMIT DISTURBANCE LIMITSAN SAN SAN SAN SAN ‘6$17<3(,,&2 RIM EL. = 900.54' INV. EL.= 895.54' /)‘39& @ 1.00% SLOPE STCB. 102 ROOF DRAIN w/ UNDERGROUND PIPE DAYLIGHT OUTSIDE FENCE CB. 105 PIPE EX. /)(;,67,1*‘6' @ 0.11% SLOPE &%,17(5&(37(;,67,1*‘6' ABANDON EAST OF CB. 104 15'-0" 15'-0" 15'-0"23'-912"28'-6"PIPE #4 /)‘+'3(&3367250 @ 1.00% SLOPE CURB TURNOUT DISCHARGE, SEE 3/C703 CURB TURNOUT DISCHARGE, SEE 3/C703 ST ST ST ST ST ST ST ST ST END SECTION, SEE 4/C703 w/ ANIMAL & DEBRIS GUARD INV. EL. = 898.60' /)‘+'3(&3367250 @ 1.25% SLOPE WTR WTR ‘'20(67,& 1 2‘,55,*$7,21 FROM BUILDING; METERS LOCATED INSIDE BLDG LOCAL (BLDG FRONT DITCH) FLOOD ELEV. = 900.00' MIN. FLOOD PROTECTION GRADE = 902.00' UTILITY NOTES UTILITY NOTES: 1.ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE LATEST STATE AND LOCAL BUILDING CODES, CITY OF CARMEL STANDARD SPECIFICATIONS AND DETAILS. 2.THE CONTRACTOR MUST VERIFY THE LOCATION AND ELEVATIONS OF ALL EXISTING UTILITIES PRIOR TO CONSTRUCTION. ANY DAMAGE TO UTILITIES OR STRUCTURES SHALL BE REPAIRED BY THE CONTRACTOR TO THE SATISFACTION OF THE UTILITY OWNER. SOME UTILITIES MAY NOT BE SHOWN. 3.ALL EXISTING RIMS AND INVERTS SHALL BE FIELD VERIFIED PRIOR TO THE START OF CONSTRUCTION. NOTIFY THE ENGINEER IMMEDIATELY IF THERE ARE ANY DISCREPANCIES. 4.ALL QUANTITIES SHOWN ARE FOR INFORMATIONAL PURPOSES ONLY. THE CONTRACTOR SHALL VERIFY ALL QUANTITIES RELATED TO CONSTRUCTION. 5.PROTECT AND BACK FILL AROUND UNDERGROUND UTILITIES. BACK FILL SHALL BE IN 6-INCH LIFTS, COMPACTED TO 95% STANDARD PROCTOR DENSITY. BUILDING DOWNSPOUTS SHALL BE CONNECTED TO NEW STORM SEWERS. 6.WHERE SANITARY SEWERS CROSS OVER OR UNDER A WATER MAIN LESS THAN 18-INCHES, REFER TO C705 CONCRETE SADDLE DETAIL. 7.ADJUSTMENTS TO EXISTING MANHOLES SHALL INCLUDE NOT MORE THAN 18-INCH OF ADJUSTING RINGS. LARGER ADJUSTMENTS MAY REQUIRE A NEW BARREL SECTION IF REQUIRED BY THE CITY/ TOWN UTILITY DEPARTMENT. 8.SANITARY SEWER SHALL BE SDR 26 PVC AT MINIMUM 1.00% SLOPE. 9.672506(:(56‘$1'‘6+$//%(&33+'3(RU5&3&/,9 10.672506(:(56‘$1'/$5*(56+$//%(5&3&/,,, 11.STORM SEWERS IN PUBLIC RIGHT-OF-WAY SHALL BE RCP, EXCEPT FOR UNDERDRIVE CULVERT THAT CAN BE CMP. 12.WATER SHALL BE PVC U.N.O.; REFER TO CITY OF CARMEL MATERIAL SPECIFICATIONS FOR ALTERNATIVE ALLOWED PIPING MATERIALS, SHOWN IN C701 13.TERMINATE PROPOSED UTILITIES 5-FEET OUTSIDE BUILDING. PLUG AND STAKE LOCATION AND ELEVATION. 14.UTILITY LENGTHS ARE CENTER OF STRUCTURE TO CENTER OF STRUCTURE. 15.COORDINATE ALL CONNECTIONS TO EXISTING WATER MAINS WITH THE CITY OF CARMEL UTILITIES & CITIZENS ENERGY GROUP . 16.MAINTAIN 5.5-FEET COVER OVER WATER MAIN AND 10-FEET SEPARATION FROM SEWERS. 17.MAINTAIN MIN. 2.5 FEET COVER OVER STORM SEWER PIPE. 18.MAINTAIN MIN. 4.5 FEET COVER OVER SANITARY SEWER PIPE. 19.PROVIDE A GRANULAR CRADLE FROM 4-INCHES BELOW TO 6-INCHES ABOVE THE STORM SEWER USING CLASS 1 MATERIAL. 20.THE FINAL SANITARY SEWER LINE MAY NOT BE CONNECTED TO THE BUILDING UNTIL CITY OF CARMEL UTILITIES & CITIZENS ENERGY GROUP APPROVES THE ENTIRE SANITARY LINE TO THE STRUCTURE LOCATED AT NORTHWEST OF THE SITE. THIS INCLUDES THE CONNECTION OF THE GREASE INTERCEPTOR, IF SPECIFIED IN THE PLAN. 21.ALL STORM SEWER FLARED ENDS MUST HAVE A GRATE. 22.REFER TO GRADING PLAN FOR OTHER NOTES THAT MAY BE APPLICABLE. 23.CARMEL UTILITIES & CITIZENS ENERGY GROUP SHALL BE NOTIFIED A MINIMUM OF 48 HOURS PRIOR TO SEWER CONSTRUCTION AND TESTING. 24.UTILITY RELOCATIONS REQUIRED BY THE PROJECT SHALL BE THE RESPONSIBILITY OF THE DEVELOPER. UTILITY LINE RELOCATIONS REQUIRED FOR ROAD PROJECTS THAT RESULT IN A CONFLICT WITH PROPOSED DEVELOPMENT SHALL BE THE DEVELOPER TO RESOLVE WITH THE UTILITY. EXISTING POLE LINES REQUIRED TO BE RELOCATED TO WITHIN ONE FOOT OF PROPOSED RIGHT-OF-WAY LINE. 1 2 3 4 5 6 1 2 3 4 5 6 D C B A 236 EAST MAIN STREETENGINEERING THAT WORKSENGINEERING WITH STYLEGAS CITY, IN 46933SCALE(36x24): SITE UTILITY PLAN C400 1 1" = 20' - 0" UTILITY PLAN C400 N SAN. STRUCTURE SCHEDULE S. MH. 101 (NEW 48" MANHOLE) CIRCULAR COVER CASTING RIM EL.= 901.40' 1,1‘39&,19(/= 893.58' 6,1‘39&,19(/= 894.83' :287‘39&,19(/= 893.48' B/O MH. EL.= 892.65' NOTE: THE STORM SEWER SYSTEM SHALL BE CONSTRUCTED PER DESIGN SPECIFIED AND AS APPROVED BY THE CITY OF CARMEL ON THE FINAL APPROVED CONSTRUCTION PLANS. DEVIATIONS FROM THE APPROVED DESIGN SHALL ONLY BE PERMITTED DUE TO SPECIAL CIRCUMSTANCES OR DIFFICULTY DURING CONSTRUCTION AND WILL REQUIRE PRIOR FIELD APPROVAL FROM A DESIGNATED REPRESENTATIVE OF THE CITY OF CARMEL IN ADDITION TO SUPPLEMENTAL APPROVAL BY THE DESIGN ENGINEER. AN EXPLANATION OF ANY SUCH DEVIATION SHALL BE INCLUDED AS A REQUIREMENT ON AS-BUILT/RECORD DRAWINGS SUBMITTED FOR RELEASE OF PERFORMANCE GUARANTEES. APPROVED DESIGN SLOPES IDENTIFIED AS GENERATING VELOCITIES OF 2.5 FPS OR LESS OR 10 FPS OR GREATER (AT FULL FLOW CAPACITY) SHALL REQUIRE AS-BUILT CERTIFICATION AT THE TIME OF CONSTRUCTION, PRIOR TO BACKFILLING THE PIPE. THE CONTRACTOR IS INSTRUCTED TO AS-BUILT EACH SECTION OF STORM PIPE AS IT IS BEING INSTALLED TO ENSURE COMPLIANCE WITH THE DESIGN PLANS AND AS APPROVED BY THE CITY OF CARMEL. STRUCTURE DATA STRUCTURE #CB 101 CB 102 CB 103 CB 104 CB 105 SIZE 24" SQ 24" SQ 24" SQ ‘0+24" SQ TYPE REINF. CONC.REINF. CONC.REINF. CONC.D-20 REINF. CONC. CASTING PARKING, CT-6 PARKING, CT-6 SQ. BEEHIVE NEENAH R-4346 CT-2 SQ. BEEHIVE NEENAH R-4346 UPSTREAM END SECTION CB 101 CB 102 CB 103, CB 105 END SECTION DOWNSTREAM CB 102 CB 103 CB 104 EX. CB.CB 104 RIM ELEV.@ 900.65'@ 900.42'@ 899.85'@ 900.26'@ 899.57' INVERTS (‘&33# (‘&33# 1(‘&33# 1‘&33# 6‘&33# :‘&33# 6:‘&33# 6‘&33# 6‘&33# 1‘&33# :‘(;6'# B/O BOX @ 896.62'@ 896.19'@ 895.60'@ 894.26'@ 895.47' REMARK ,17(5&(37(;‘ SD. NOTE:STRUCTURE & CASTING NUMBERS ARE PER HAMILTON CO. STD. DRAWINGS PIPE DATA PIPE #UPSTREAM DOWNSTREAM LENGTH SLOPE SIZE MATERIALSTRUCT.INV. EL.STRUCT.INV. EL. 1 CB 101 897.12'CB 102 896.79'99.5'0.33%‘CPP 2 CB 102 896.69'CB 103 896.20'122.0'0.40%‘CPP 3 CB 103 896.10'CB 104 895.86'92.0'0.26%‘CPP 4 END 896.20'CB 105 896.07'13.0'1.00%‘CPP 5 CB 105 895.97'CB 104 895.86'33.0'0.33%‘CPP 6 END 898.60'CB 101 897.22'110.0'1.25%‘CPP EX.CB 104 895.76'EX. CB.895.73'27.0'0.11%‘RCP