HomeMy WebLinkAboutElevationsFINISH FLOOR
0' -0"
ASPHALT SHINGLES -M-2
PRE-FINISHED ALUMINUM
TRIM -M-3
PRE-FINISHED ALUMINUM
GUTTER & DOWN
SPOUTS -M-6
BRICK VENEER -M-1
SPLIT-FACE CMU -M-9
STONE SILL & COLUMN -M-5
STANDING SEAM METAL
ROOF -M-8
20' - 2 1/4"
15' - 0 1/2"
6
AE2-001a
21' - 0"
27' - 2 5/8"11' - 10"EXT DOORS -M-12
EXT WINDOWS -M-10
3 1/2"
12"
4"
12"
SPANDREL GLASS (5)
20' - 6 7/8" HP
3"
12"
14' - 8" MP
FINISH FLOOR
0' -0"
ASPHALT SHINGLES -M-2
PRE-FINISHED ALUMINUM
TRIM -M-3
SIDING -M-4
PRE-FINISHED ALUMINUM
GUTTER & DOWN
SPOUTS -M-6
BRICK VENEER -M-1
SPLIT-FACE CMU -M-9
STONE SILL 7
COLUMN -M-5
21' - 0" HP
13' - 2 5/8" HP 13' - 2 5/8" HP
27' - 2 5/8"
5
AE2-001aPROPOSED 100" X 24" SIGN -SIGN TO BE
PERMITTED UNDER SEPARATE SUBMITTAL BY
SIGN VENDOR
8' - 3 3/4"4 5/8"
12"
4 5/8"
12"
STOREFRONT -M-11
EXT DOORS -M-12
EXT WINDOWS -M-10
7
AE2-001a
20' - 6 7/8" HP
7' - 9 3/4"ENTRY LIGHTING -TYP
14' - 8" MP 14' - 8" MP15' - 0" MP
SYMBOL ITEM MANUFACTURER MODEL COLOR / FINISH REMARKS
M-1
M-2
M-3
M-4
M-5
M-6
M-8
M-9
BRICK
ASPHALT SHINGLES
BREAK METAL TRIM
VINYL SIDING
SILLS & COLUMNS
PRE-FIN ALUM
GUTTER
STANDING SEAM
METAL ROOF
SPLIT FACE CMU
EXTERIOR ELEVATION MATERIALS
BRAMPTON BRICK
GAF ROOFING
QUALITY EDGE
GEORGIA PACIFIC
ESCHELON MASONRY
PLY-GEM MASTIC
McELROY METAL
ESCHELON MASONRY
CROSSROADS SERIES
TIMBERLINE HD -LIFETIME
SHINGLES
TRULINE EMBOSSED TRIM COIL
FOREST RIDGE DOUBLE 5" SIDING
CORDOVA STONE
5" K-STYLE SEAMLESS GUTTER
INSTALOC STANDING SEAM
SYSTEM, STYLE -PLANK PROFILE
MESASTONE
JASPER
WEATHERED WOOD
807 CLAY
MIST
LIMESTONE,
GROUNDFACE
PEBBLESTONE CLAY
COPPER PENNY
METALLIC
COUNTY GRAY
NOTE:
-TYPICAL DORMERS M-4 SIDING, PAINT TRIM SW9172 TO MATCH.
-CUPOLA TO BE PAINTED CLAY & DESERT SAND, PAINT SW9117 TO MATCH M-3.
IF BRICK IS NOT READILY
AVAILABLE PROVIDE OPTIONS
FOR OWNER TO APPROVE
IF CMU IS NOT READILY
AVAILABLE PROVIDE OPTIONS
FOR OWNER TO APPROVE
M-10
M-11
M-12
WINDOW FRAME
STOREFRONT
EXTERIOR DOORS
JELD-WEN
-
SHERWIN WILLIAMS
VARIES -REFER TO
WINDOW TYPES
-
-
DESERT SAND
DARK BRONZE
ALUMINUM
HM DOOR, PAINT, SW701 GRAY SCREEN SEMIGLOSS
HM FRAME, PAINT -TIMELY SC103 BLACK
FINISH FLOOR
0' -0"
ASPHALT SHINGLES -M-2
PRE-FINISHED ALUMINUM
TRIM -M-3
SIDING -M-4
PRE-FINISHED ALUMINUM
GUTTER & DOWN
SPOUTS -M-6
BRICK VENEER -M-1
SPLIT-FACE CMU -M-9
STONE SILL -M-5
21' - 0" HP
8' - 3 3/4"18' - 9 1/4"EXT WINDOWS -M-10
EXT DOORS -M-12
SPANDREL GLASS (1)
EXT WINDOWS -M-10
3"
12"
20' - 6 7/8" HP
14' - 8" MP
19' - 8 3/8" MP
16' - 3 3/8" MP
FINISH FLOOR
0' -0"
ASPHALT SHINGLES -M-2
PRE-FINISHED ALUMINUM
TRIM -M-3
PRE-FINISHED ALUMINUM
GUTTER & DOWN
SPOUTS -M-6
BRICK VENEER -M-1
SPLIT-FACE CMU -M-9
STONE SILL -M-5
27' - 2 5/8"
20' - 2 1/4"
15' - 0 1/2"
ROOF VENTS -PAINT TO
MATCH ROOF SHINGLES
(TYP)7' - 8 5/8"11' - 1 3/4"21' - 0" HP 20' - 6 7/8" HP
3 1/2"
12"
14' - 8" MP
CONCEALED FLASHING
1/2" SOLID CELLULAR PVC
SHEET ON SELF-ADHERED
ROOFING UNDERLAYMENT
ON 1/2" APA RATED
SHEATHING ON HORIZONTAL
2X4 WOOD STUDS AT 16" ON
CENTER ON 2X4 WOOD
STUDS AT 16" ON CENTER
ALUMINUM CLAD SILL
W/ DRIP EDGE
1X4 TRIM BOARD PAINTED2' - 6"WINDOW -TYPE B ON ALL
4 SIDES
1X CORNER BOARD PAINTED
ON 1/2" PACK OUT
1X10 TRIM BOARD PAINTED
1X4 TRIM BOARD PAINTED
1X6 FASCIA TRIM BOARD PAINTED
PREFINISHED METAL STANDING
SEAM ROOFING ON 30LB
ROOFING FELT ON 1/2" APA
RATED SHEATHING ON 2X6
WOOD ROOFING FRAMING AT
16" ON CENTER
12
10
9 1/2"2' - 6"9 1/2"
FINISH FLOOR
0' -0"
SPLITFACED CMU
NOTE:THREE FULL
COURSES
2 5/8" ± (ONE BRICK)
2 5/8" ± (ONE BRICK)
2 5/8" ± (ONE BRICK)
8" ± (SOLDIER COURSE)
BEHIND TRIM
1X4 TRIM BOARD ON 1X12
SUB BOARD WITH PRE-
FIN ALUMINUM WRAP
PRE-FIN ALUMINUM
GUTTER
FASCIA BOARD W/
PRE-FINISHED
ALUMINUM WRAP
CAST STONE SILL1' - 4"1' - 4"1' - 4"2' - 0"7' - 10 3/4"
SPANDREL PANEL BY SIGN VENDOR
is a member of the IBI Group of companies
DATE:
ISSUE
SHEET TITLE
PROJECT
SCALE:
APPROVED BY:PROJECT MGR:
PROJECT NO:
SHEET NUMBER
CLIENT
COPYRIGHT
ISSUES
This drawing has been prepared solely for the intended use, thus any reproduction
or distribution for any purpose other than authorized by IBI Group is forbidden.
Written dimensions shall have precedence over scaled dimensions. Contractors
shall verify and be responsible for all dimensions and conditions on the job, and IBI
Group shall be informed of any variations from the dimensions and conditions
shown on the drawing. Shop drawings shall be submitted to IBI Group for general
conformance before proceeding with fabrication.
IBI Group Engineering Services (USA) Inc.NOT FOR CONSTRUCTIONCHECKED BY:DRAWN BY:SCALE CHECKSEAL
3221 W Big Beaver, Suite 111
Troy, MI, 48084
10mm1 inCONSULTANTS
As indicated
D C:\Users\corrinne.greer\Documents\REVIT2018\122885_814KC CrmlIN_arch_v18_corrinne.greer.rvtEXTERIOR ELEVATIONS
122885
M.STOCK
2020-02-19
AE2-001a
KINDERCARE LEARNING
CENTER
L.SMIGLIANI
CARMEL, IN
C.GREER E.SHELINE
SCALE:1/8" = 1'-0"AE1-100a
EAST ELEVATION1
SCALE:1/8" = 1'-0"AE1-100a
NORTH ELEVATION2
SCALE:1/8" = 1'-0"AE1-100a
SOUTH ELEVATION3
SCALE:1/8" = 1'-0"AE1-100a
WEST ELEVATION4
SCALE:1/2" = 1'-0"AE2-001a
ELEVATION DETAIL - CUPOLA
5
SCALE:1/2" = 1'-0"AE2-001a
ELEVATION DETAIL - QUION
6
No. DESCRIPTION DATE
A SITE PLAN REVIEW 2019-11-08
B SITE PLAN REVIEW REV01 2020-02-21
C SITE PLAN REVIEW REV02 2020-03-18
D SITE PLAN REVIEW REV03 2020-05-05
SCALE:3/8" = 1'-0"AE2-001a
ELEVATION DETAIL - SIGNAGE
7