HomeMy WebLinkAboutA100.10TT2'-8"2'-8"CAST-IN-PLACE CONCRETE MONOLITHIC SLAB
FINISH GRADE
2" FOAM INSULATION
UNDISTURBED EARTH
6 MIL VAPOR BARRIER OVER COMPACTED
GRAVEL FILL
1/2" Ø X 12"L ANCHOR BOLTS; 72" O/C & WITHIN
12" OF ALL PLATE ENDS
TREATED 2X4 BOTTOM PLATE
SIGA FLASHING TAPE AT BOTTOM OF WALL
SHEATHING TO FACE OF NEW FOUNDATION WALL
5/4X8 PREFINISHED FIBER CEMENT BOTTOM
BAND BOARD
2X4 WALL STUDS @ 16" O/C
7/16" OSB WALL SHEATHING
TYVEK (OR EQUIV.) HOUSEWRAP WITH TAPED
SEAMS
PREFINISHED FIBER CEMENT WOOD-GRAIN
TEXTURED SIDING WITH 6" EXPOSURE
R-15 KRAFT-FACED BATT INSULATION
1/2" DRYWALL ON WALLS, FINISHED
NEW GARAGE
1/2" DRYWALL ON CEILING, FINISHED
2X10 CEILING JOISTS @ 16" O/C
R-38 KRAFT-FACED BATT INSULATION
SIMPSON STRONG-TIE H1 (OR EQUIV.) TIE-
DOWN @ EVERY RAFTER
DOUBLE 2X4 TOP PLATE
5/4X6 PREFINISHED FIBER CEMENT FRIEZE BOARD
3/8" ROUGH-SAWN FIR PLYWOOD SOFFIT WITH
ALUMINUM SOFFIT VENTS
6" ALUMINUM GUTTER
1X6 ROUGH-SAWN CEDAR FASCIA
2X6 SUB-FASCIA
ALUMINUM GUTTER APRON
ICE & WATER SHIELD (UP 3' FROM EDGE OF
EAVE)
2X6 RAFTERS @ 16" O/C
7/16" OSB ROOF DECKING
SYNTHETIC UNDERLAYMENT
DIMENSIONAL SHINGLES
CAST-IN-PLACE CONCRETE MONOLITHIC SLAB
FINISH GRADE
2" FOAM INSULATION
UNDISTURBED EARTH
6 MIL VAPOR BARRIER OVER COMPACTED
GRAVEL FILL
4X4 ROUGH-SAWN CEDAR POST
NEW PORCH
3/8" ROUGH-SAWN FIR PLYWOOD SOFFIT WITH
ALUMINUM SOFFIT VENTS
6" ALUMINUM GUTTER
1X6 ROUGH-SAWN CEDAR FASCIA
2X6 SUB-FASCIA
ALUMINUM GUTTER APRON
ICE & WATER SHIELD (UP 3' FROM EDGE OF
EAVE)
2X6 RAFTERS @ 16" O/C
7/16" OSB ROOF DECKING
SYNTHETIC UNDERLAYMENT
DIMENSIONAL SHINGLES
SIMPSON STRONG-TIE APVB44R BLACK
POWDER-COATED POST BASE WITH BLACK
POWDER-COATED LOBE WASHER HEAD
STRUCTURAL SCREWS & HEX-HEAD WASHERS
SIMPSON STRONG-TIE H1 (OR EQUIV.) TIE-
DOWN @ EVERY RAFTER
2-PLY 2X10 HEADER
SIMPSON STRONG-TIE APVA4 BLACK POWDER-
COATED ANGLE WITH BLACK POWDER-COATED
LOBE WASHER HEAD STRUCTURAL SCREWS &
HEX-HEAD WASHERS
1X ROUGH-SAWN CEDAR HEADER WRAP
2X4 ROUGH-SAWN CEDAR LATERAL BRACE
2'-0"4"8"
(MATCH EXISTING GARAGE SLAB ELEV)
TOP OF NEW SLAB
-3' 4"
BOTTOM OF NEW STEM WALL
(MATCH EXISTING TOP PLATE HEIGHT)
TOP OF WALL
3" BELOW HOUSE FINISHED FLOOR
TOP OF NEW SLAB
-3' 4"
BOTTOM OF NEW STEM WALL
(MATCH EXISTING TOP PLATE HEIGHT)
TOP OF HEADER
4"8"
80" ABOVE NEW SLAB
BOTTOM OF LATERAL BRACE
1 1/2"2X6 SYP RAFTER @ 16" O/C
SIMPSON STRONG-TIE LRUZ
(OR EQUIV.) RAFTER HANGER
2-PLY 14" LVL RIDGE BEAM
7/16" OSB ROOF DECKING
1X8 ROUGH-SAWN CEDAR ON
EACH SIDE OF RIDGE BEAM
RIPPED DOWN 1X6 ROUGH-
SAWN CEDAR BELOW RIDGE
BEAM (ALLOW 1-1/2"
RACEWAY FOR WIRING AS
SHOWN)
PERMIT
#0
ISSUE DATE:
2020-05-26
REV:
www.caseindy.com
99 E. Carmel Drive, Suite 100
Carmel, Indiana 46032
317.846.2600 317.846.2601(f)
These drawings have been prepared by Case
Design & Remodeling solely for its use and
should not be reproduced or relied upon by any
other parties. Dimensions shown or scaled are
subject to change per actual job condition and
must be verified. Materials are to be supplied as
specified as equal or standard when not
uniquely specified. Installed materials may vary
in appearance from drawings. Reference
manufacturer's product data for actual
appearance and specifications.LYONS PROJECTEXTERIOR RENOVATION AND GARAGE & BACKPORCH ADDITIONGREG & JESSECA LYONS13535 SHELBORNE ROADCARMEL, INDIANA 46074Approved By:
Date:
A601
Craig Dice
Architectural Designer
cdice@caseindy.com
David Null
Project Developer
dnull@caseindy.com
242160228
JOB NUMBER:
#1 2020-05-28
TYPICAL GARAGE WALL SECTION A
A601
A
A601 SCALE: 3/4" = 1'-0"
TYPICAL PORCH WALL SECTIONB
A601
B
A601 SCALE: 3/4" = 1'-0"
PORCH RIDGE DETAILC
A601
C
A601 SCALE: 1" = 1'-0"
06/10/20
Adam Schriner