HomeMy WebLinkAboutA100.10TT2'-8"2'-8"CAST-IN-PLACE CONCRETE MONOLITHIC SLAB FINISH GRADE 2" FOAM INSULATION UNDISTURBED EARTH 6 MIL VAPOR BARRIER OVER COMPACTED GRAVEL FILL 1/2" Ø X 12"L ANCHOR BOLTS; 72" O/C & WITHIN 12" OF ALL PLATE ENDS TREATED 2X4 BOTTOM PLATE SIGA FLASHING TAPE AT BOTTOM OF WALL SHEATHING TO FACE OF NEW FOUNDATION WALL 5/4X8 PREFINISHED FIBER CEMENT BOTTOM BAND BOARD 2X4 WALL STUDS @ 16" O/C 7/16" OSB WALL SHEATHING TYVEK (OR EQUIV.) HOUSEWRAP WITH TAPED SEAMS PREFINISHED FIBER CEMENT WOOD-GRAIN TEXTURED SIDING WITH 6" EXPOSURE R-15 KRAFT-FACED BATT INSULATION 1/2" DRYWALL ON WALLS, FINISHED NEW GARAGE 1/2" DRYWALL ON CEILING, FINISHED 2X10 CEILING JOISTS @ 16" O/C R-38 KRAFT-FACED BATT INSULATION SIMPSON STRONG-TIE H1 (OR EQUIV.) TIE- DOWN @ EVERY RAFTER DOUBLE 2X4 TOP PLATE 5/4X6 PREFINISHED FIBER CEMENT FRIEZE BOARD 3/8" ROUGH-SAWN FIR PLYWOOD SOFFIT WITH ALUMINUM SOFFIT VENTS 6" ALUMINUM GUTTER 1X6 ROUGH-SAWN CEDAR FASCIA 2X6 SUB-FASCIA ALUMINUM GUTTER APRON ICE & WATER SHIELD (UP 3' FROM EDGE OF EAVE) 2X6 RAFTERS @ 16" O/C 7/16" OSB ROOF DECKING SYNTHETIC UNDERLAYMENT DIMENSIONAL SHINGLES CAST-IN-PLACE CONCRETE MONOLITHIC SLAB FINISH GRADE 2" FOAM INSULATION UNDISTURBED EARTH 6 MIL VAPOR BARRIER OVER COMPACTED GRAVEL FILL 4X4 ROUGH-SAWN CEDAR POST NEW PORCH 3/8" ROUGH-SAWN FIR PLYWOOD SOFFIT WITH ALUMINUM SOFFIT VENTS 6" ALUMINUM GUTTER 1X6 ROUGH-SAWN CEDAR FASCIA 2X6 SUB-FASCIA ALUMINUM GUTTER APRON ICE & WATER SHIELD (UP 3' FROM EDGE OF EAVE) 2X6 RAFTERS @ 16" O/C 7/16" OSB ROOF DECKING SYNTHETIC UNDERLAYMENT DIMENSIONAL SHINGLES SIMPSON STRONG-TIE APVB44R BLACK POWDER-COATED POST BASE WITH BLACK POWDER-COATED LOBE WASHER HEAD STRUCTURAL SCREWS & HEX-HEAD WASHERS SIMPSON STRONG-TIE H1 (OR EQUIV.) TIE- DOWN @ EVERY RAFTER 2-PLY 2X10 HEADER SIMPSON STRONG-TIE APVA4 BLACK POWDER- COATED ANGLE WITH BLACK POWDER-COATED LOBE WASHER HEAD STRUCTURAL SCREWS & HEX-HEAD WASHERS 1X ROUGH-SAWN CEDAR HEADER WRAP 2X4 ROUGH-SAWN CEDAR LATERAL BRACE 2'-0"4"8" (MATCH EXISTING GARAGE SLAB ELEV) TOP OF NEW SLAB -3' 4" BOTTOM OF NEW STEM WALL (MATCH EXISTING TOP PLATE HEIGHT) TOP OF WALL 3" BELOW HOUSE FINISHED FLOOR TOP OF NEW SLAB -3' 4" BOTTOM OF NEW STEM WALL (MATCH EXISTING TOP PLATE HEIGHT) TOP OF HEADER 4"8" 80" ABOVE NEW SLAB BOTTOM OF LATERAL BRACE 1 1/2"2X6 SYP RAFTER @ 16" O/C SIMPSON STRONG-TIE LRUZ (OR EQUIV.) RAFTER HANGER 2-PLY 14" LVL RIDGE BEAM 7/16" OSB ROOF DECKING 1X8 ROUGH-SAWN CEDAR ON EACH SIDE OF RIDGE BEAM RIPPED DOWN 1X6 ROUGH- SAWN CEDAR BELOW RIDGE BEAM (ALLOW 1-1/2" RACEWAY FOR WIRING AS SHOWN) PERMIT #0 ISSUE DATE: 2020-05-26 REV: www.caseindy.com 99 E. Carmel Drive, Suite 100 Carmel, Indiana 46032 317.846.2600 317.846.2601(f) These drawings have been prepared by Case Design & Remodeling solely for its use and should not be reproduced or relied upon by any other parties. Dimensions shown or scaled are subject to change per actual job condition and must be verified. Materials are to be supplied as specified as equal or standard when not uniquely specified. Installed materials may vary in appearance from drawings. Reference manufacturer's product data for actual appearance and specifications.LYONS PROJECTEXTERIOR RENOVATION AND GARAGE & BACKPORCH ADDITIONGREG & JESSECA LYONS13535 SHELBORNE ROADCARMEL, INDIANA 46074Approved By: Date: A601 Craig Dice Architectural Designer cdice@caseindy.com David Null Project Developer dnull@caseindy.com 242160228 JOB NUMBER: #1 2020-05-28 TYPICAL GARAGE WALL SECTION A A601 A A601 SCALE: 3/4" = 1'-0" TYPICAL PORCH WALL SECTIONB A601 B A601 SCALE: 3/4" = 1'-0" PORCH RIDGE DETAILC A601 C A601 SCALE: 1" = 1'-0" 06/10/20 Adam Schriner