HomeMy WebLinkAboutM001.0_ Mechanical HVAC PlanRELEA5E0 FOR CONSTRIICTI�N
Su6jec��o compliance with allregula�ions
of S�a�e antl Local Codes
City of Carmel
�un��\i lo•rvalM.��
oarE: 06/11 /20
/
�0 NOT SCALE FROM ORAWINGS. REFER 70 ARCNITEC7URAL
FFE PLAN & COORDINAiE EQUIPMENi LOCAilONS IN FIELO WRN
MILLWORK. VERIFY CURRENi EQUIPMENi REQUIREMENiS
(CONNECiION iYGE, HEIGNiS, EiC.) WIiH EQUIPMENi VEN�OR.
��
� S
5-3 Y
200
CFM i
� //_,
l ll
e^m
v_
�
ro
s-3
900
,FM a
o�
v
5-3
300
CFM m
o�
I =
� I LL
S 3 �
200 Riu
ti�T1P
CFM ` I k �
��— -�� � i
ro
�� I �
��;�.F�J
� �
� i �
RS � � �
f6 — —
I
�
� �
"so S_4 i
— R-i aoa ;
600 CFM �
�V CFPI
� IOrm
S-3
?0�
CFM
rrA / S-4
L 500
� CFM
S-3
300
CFM
� �
F�
� 5-4
400
r�� CPM
V�
"r
A
�;��5-4
480
CFM
18/16 10/li
�
\
� {P'
�
S-4 I /� � EP y' S-4
aoo i� aoo
CFM _� \ CPM
10"6 �
;''�Yii 22/18
`
e 5-4
0 4pQ
CFM
o a
� 5-4
� 500
�� CFM
28/ 18
_/° ; _,
S-4
400
CFM
� M101 HVAC PLAN
SCALE: 1/4'-1'-0'
� OA
�/
�%J
6"m
/
� �'-
I /
��������� �
nao
CFM
� �
R—I
/ I 50 4000
� � CfFI
i �
&
\m��
5—. V J v
s �
r� n
--� EF �� L'�
3
CONS'fRUC'fION NOTES
�INSTAII GREASE MA57ER PREFABRICA"fED GREASE
DUCi. DUCi i0 CONNECi i0 HOOD COLLARS AN� RUN
UP i0 EF—I ON ROOF, AS SHOWN. PROVIDE A MIN. Yy"
PER FOOi OF SLOPE. MC i0 COORDINAiE WIiH GC TO
MAINiAIN 18" CLEARANCE i0 COMBUSiI0LE5 OR PROVIDE
REQUIRED FIRE WRAP. INSiAII FACiORY BUIIi ACCESS
PANELS EVERY 20" AND AT ALL DIRECiION CHANGES,
AS PROVIDED. REVIEW GREASE MASTER FULL SELECiION
DRAWINGS PRIOR i0 BID. M.C. i0 COOROINAiE WIiH
HOOD COMPANY FOR DUCi ROUiING AND REQUIRED
HiiING i0 ALLOW GREASE OUCi i0 RUN OEiWEEN
TRUSSES COORDINAiION TO BE COMPLEiED EARLY
ENOUGH TO ALLOW DUCi GRODUCTION ON SCHEDULE.
COORDINAiE ALL WORK WIiN G.C. AND LANDLORD.
�18/16 GALVANIZED E%HAU57 DUC7 UP i0 EF-2 ON
ROOF FOR TYPE II PIZZA OVEN HOOD. EF—I, EF-2 AND
DOAS—I i0 0E INiERLOCKED WIiH CREASE MASiER DCV
CONTROL SYSiEM. COOROINAiE WORK WIiH G.C. ANO
zooFwc coNlancroa.
�DOAS—I i0 BE PROVIOED WITH iHE GREASE MASiER
HOOD PACKAGE. iH15 UNIi IS 100% OUiSIDE AIR DURING
OPERAiING HOURS ANO WILL RUN Ai A LOW OUiPUi
RECIRCULAiE MOOE OURINC UNOCCUPIEO HOURS. UNIi i0
BE IMERLOCKED WIiH HOOD EXHAUSi i0 MAINiAIN
SPACE BALANCE.
�MOUNT FANS AND POSITION QTUS 70 MAW7AIN 10�
MINIMUM 0.EARANCE BEiWEEN EXHAU57 AND OUTSIDE
AIR WiAKES. VERIFY ALL 0.EARANCES AND SPACING
PRIOR i0 BID. COORDINAiE ALL ROOF WORK WIiH G.C.
AND LANDLORO ROOFING CONiRACiOR.
�INSiALL H000 ROOM TEMPERATURE SENSOR AND
DOAS—I REMOTE SENSOR. HOOD SENSOR TO BE WIRED
i0 iHE N000 STARTER PANEL AS INDICATED ON SHEEi
M4 COORDINAiE WORK WIiH G.C.
�REM07E SENSOR FOR RN CONTROLS — FINAL
CONNECilONS BY RN CONiRAC70R. CONDUIT AND
WIRING BY ELECiRICAL CONiRACiOR — TYPICAL ALL
SYSiEMS. CENiRAL CONiROLS IN OFFICE — VERIFY
LOCAiION WIiH OWNER. LOCAiE SENSORS ON WAIL Ai
6"-0" A.F.F. DIFFUSER AND SENSOR LOCAilONS CANNOi
BE CHANGED WIiHOUT PRIOR APPROVAL FROM iHE
CONSULiING ENGINEER.
�MOUNT FIRE/ SMOKE DETEC10k5 IN THE 2ETURN
HOUSING IN AN ACCESSIBLE AREA TYPICAL ALL UNITS.
�REiURN GRILLES — VOLUMES VARY OEPENDING ON
OCCUPIEO OR UNOCCUPIED OPERAiION. INSiALL
ACOUSiIC DUCi LINER AND CONSi2UCi 2ETURN PLENUM
TO ELIMINATE DIRECT LWE OF SIGHi FROM CRILLE i0
FAN.
�P20VIDE VOWME DAMPERS ON ALL 82ANCNES, ALL
SY57EMS — 7YPICAL.
Im UNDERCUi DOOR.
C�'\I��i,�������
I. DUC75 ARE SIZED FOR FREE AREA. DIMENSIONS AND
LOCAilONS CAN BE CHANGED AS LONG AS VELOQTIES
AND PRESSURE DROPS ARE MAWTAWED.
2 DUCi SIZING AS FOLLOWS: FIRSi NUMBER IS FOR SIDE
SHOWN — SECONO NUMBER IS FOR SIOE NOi SHOWN.
RAi10 SHALL NOT EXCEED I:S. INSiALL EXiERIOR
INSULAiION ON SUPP�Y & RE"fUQN.INSiALL ALL DUCi
PER "85 SMACNA 57ANDARDS.
3. LOCAiE ALL EXHAUST OUiLETS TO MAINiAIN A MINIMUM
10'-0" FROM ALl OUiSIDE AIR INiAKES.
4. WE�DING OR ORI�LING OF SiRUCN2AL MEMBERS IS NOi
ALLOWED.
5. SEE M2 F02 NVAC EQUIPMENi SCHEOULES.
6. SEE M3 FOR HVAC OEiAILS.
7. ALL CONiRAC70R5 "f0 PROVIDE AS BUIL7 REDUNED
DRAWINGS 70 7HE OWNER. Ai iHE COMPLE"fION OF
EACH PROJECi.
8. M.C. i0 COORDINAiE ALL WORK OUi51DE OF iENANi
SPACE WIiH LANDLORO CONiRACiOR PRIOR i0 BID.
COORDINAiE WORK COSi WIiH C.C.
�
3
rc
O O
0
+
Q z a
� �
"� °1 � Q
w LL �--�
� �
o W
NJ + N
� w�
� � ..��o
w � LL oe
�
� N 6'
� �� Qx
d � o
0
Q � c � sm
o e6 ¢
Z mz
d w J J^=
Q
� ~ a �
Q � O
� � J
� 3
� a
0
ti
�
� 1� ¢
� � o
o W �
��.+ N <
i N�<
.. �Nz
i
i w
LL �WW
F z�
� m 6
� ~�
0
0
0
6 3 3
i � �
$ � � —
o _ � � � o
6 PROFESSIONAL SEAL: o
" lEY F. M����=.
�(�ST
�_
9-. WE
QF `2 .
�"��'��ONA� E�� � �
SHEET NUMBER:
M1oF13