HomeMy WebLinkAboutS-531-PCC-BEAM-DETAILS---STRUCTURAL-Rev.1� a O i6'-0" � �APPE�BRG,REFER TO �ET 315�531 NNJF � PCC FIELD-TOPPED DOUBLE TEE PROFILE � 12. _ �._p�. AFTERERECTION, — REMOVE ALL WNTER FROM CAVITY 8 FlLL ENTIRE V01� W/ SILICONE SEALANT. SET PLUG INTO SEALANTAN� REMOVEE%CESS. PCC PWG TO MATCH suRaouNomc 3" 0 MA% AT TOP PANDRELS 0 IGHT WALLS A"ID MAX PT TOP OF COL / PCCEMBED�E� J � LIFTWG INSERT LIFTING INSERT DETAIL 3" _ �'-0" RELEA5E0 FOR CONSTRUCTION Suhjec� �o compliance with all regula�ions 04 S�a�e antl Local Codes City of Carmel y" �n„� ��.�a,�,a' onrE: 06/11 /20 STEM REWE REFER O TO �ET 1NS531 il I 6' WIDE x 4" HIGH BLOCKOl1T.ALIGNIN � TOP OF TEE STEM, TYP I � TEE II Q I -I__- - � ��, CG PRESTRESSING P` II STRANDS UN�APPE� BRG, REFER TO DET 215-531 SIDE ELEVATION � TOPOFSPANDREL, LIGHT WALL OR COLUMN � � 7 � EXTERIOR FACE OF PCCSPAN�REL DRIP DETAIL s.=,.o. ene� i ivry uhr H: REQUIRE� BV PC BEARWG PLATE .G2 BEARING PLATE Ash Avh Avf � 0 � � c v PRESTRESS REINF @TOP[MIN1J8 MID HEIOHT [MIN PJ INSIDE FACE PRESTRESS REINF @ BOT il2' DIA STRANDS (MIN 2) CONT DRIP REF TO DET 13/5-531 PIPE SLEEVE, COORD SIZE 8 LOCATION W/ ELEC & FIRE PROTECTION �WGS J= � PRESTRESS REINF BEAM TYPE A DETAIL PCC BEAM TYPE B DETAIL PCC BEAM TYPE C DETAIL 2 3�4•=,-0• TEE DETA L 3 3�4•=,-0• L � 3�4._,-0. 5 3�4._,.-0. 6 3�4.,_,._o. � CONTDRIP. kEF TO DET 13IS53� NOTE' FOR ADDL MFORMATION, REFER TO DETAIL B/5531 � PCC BEAM TYPE D DETAIL � 314'• =1• 0" PCC BEAM PCC TEE STEM BEARING PLATE, REFER TO DET ?/S-??? BEARING PA� SPANDREL OR WALL p4XCONT � CONNECTION BY PCC MFR � PRESTRESS REINF � TOP (MIN Q1 & MID HEIGHT (MM flJ INSIDE FACE PCC BRACKET PRESTRESS REINF @ BOT 1/2" �IA STRAN�S (MIN 2) CONTDRIP REF TOOET 13/5-531 COVESEALANT REFER TO �ET 6/5-541 CIP TOPPING WWF TIE PROJECTION INTO WASH TOPPING ROUGHEN SURFACE TOPBARS STIRRUPS AFTER ERECTION, TOP OF SPANDREL, REMOVEALLWATER �1"OMAX LIGHTWALLOR FROMGAVITV&RLL �� � COWMN ENTIRE VOI� WI BEARINGPA� EPO%YTOBOT \ a " � � — EPDXYTOeOT OFPCCTEE " OF BEAM CONCDAM � CHAMFER BRGANGLE �� � � ^ RBNF,REFER tol I q3@EA �� TOPLAN BRG PL LEDGE OR I I TEE STEM ��2„ �, �,�� CORBEL PCCEMBEDOED HOL� ,�MW LE�GEOR HOL� MIN 12"@ PCCTEE LIFfINGINSERT CORBEL SPAN� PKT n BEAM BEARING DETAIL � TEE BEARING DETAIL n PCC FIELD-TOPPED DETAIL n LIFTING INSERT DETAIL ° ivz.._�._o. a ui2._�._p. iv sw._��_o, i i 3.._�._p�. � 5/8" 0 SMOOTH BAR X �'-0" (S5J SEALANT,REFERTO�ET384/5-5h1 � 1� CIP CONC TOPPING J , ___ ___" `I 'Y. 0 accreeF�aNce � % � uaCe�-0•iss�oaoavroN "� BACKERROD� �Sl1PERI0RP11SHEARGRIP 8� CONNECTOR �� NOTE: BARS OF VARIOUS SIZES MAY BE REQD �EPEN�ING UPON FlEL� CONDITIONS. PRE CASTER SHALL KEEP ADEpUATE SIIPPLY OF SIZES ON SITE TO FAQLITATE ERECTION. PCC TEE JOINT DETAIL 3._� Q. Ash ERECTION�APA', RWUIRE� BYPC MSKTD & Associates ArchitecNre I Engineering I Interior Design 1�15 Magnavox Way I 930 Nohh Mentlian Fort Wayne, IN 46804 Intlianapolis, IN 46204 260.432.9337 31].917.1190 www mskld com �WGIo 8910 Purdue Rd, Suite 400 Indianapolis, IN 46268 Phone No. 317.735.3349 www.wginacom 1�/i! 2�15 GPJ�a P �'�b ' by Na. * PE10300054�* STATEOF / � S' � U • � U � � � O � � — — v� U �0 X � � W Z U O � Y .� � � � � � � � a� w � � � Z I� U � PROJECTNO. DATE 7382 10/11 /2019 REV. DATE SET DESCRIPTION BP #4 - Garage / Bridge Structural Package SHEET TITLE PCC BEAM DETAILS - STRUCTURAL SHEETNUMBER S-531 END ELEVATION A-A