Loading...
HomeMy WebLinkAboutT0-00-TECHNOLOGY-COVERSHEET-Rev.0VIEW KEY �NAME�LEVELNAME ��INOICATESNOTEUSEDTODESCRIBE 10'-0"�HEIGHTABOVE AD�ITIONALINFORMATIONABOUT PROJECTO'-0" WORKREQUIRED,SPEQFICTOTHE SHEET ANDIOR DETAIL INDICATES DIRECTION OF TRUE NORTH PLAN OR �ETAIL NUMBER � PLAN OR DETAIL NAME , � VIEW NAME il8" = 1'-0" � PLAN OR DETAIL SCALE '�'�RS� INDICATES SIMILAR DETAIL SI�REFERENCED IN MULTIPLE LOCATIONS DETAIL REFERRED TO BV SECTION CUT 1 M101 SHEETDETAILISLOCATE�ON INDICATES SIMILAR DETAIL REFERENCED IN MULTIPLE LOCATIONS SI �DETAIL REFERRED TO BY ELEVATION 4 3 T101�SHEET DETAIL IS LOCATED ON LINE TVPE KEV: NEW WORKBYTHISCONTRACTOR (DARK SOLID LME) NEW WORK 11NDERFLOOR OR UNDERGROUND BV THIS CONTRACTOR (DARK LONG DASHED LINE) NEW W ORK BY OTHERS AND/OR EXISTING TO REMAIN (LIGHT SOLID LINE) ------- EXISTING TO BE REMOVED BV THIS CONTRACTOR (DARK SHORT DASHED LINE) F_\ :1:1: � � �] x.YN :7131 U1. G AV.C. AUDIONISUALCONTR4CTOR GG CNIL CONTRACTOR C M. CONSTRUCTION MANAGER E.G ELECTRICALCONTRACTOR FP.C. FIREPROTECTIONCONTRACTOR F.SL. FOOD SERVICE CONTRACTOR G.C. GENER4LCONTRACTOR H.C. HEATINGCONTRACTOR M.C. MECHANICALCONTRACTOR N.GC. NURSE CALL CONTRACTOR P.C. PWMBINGCONTRACTOR S.G SECURITV CONTRACTOR TL. TECHNOLOGVCONTRACTOR T.GG TEMPERATURECONTROLSCONTRACTOR V.C. VENTILATION CONTRACTOR ABBR: I DESCRIPTION: AFF ABOVE FINISHED FLOOR BFC BELOWFINISHEDCEILING C CONDUIT J-BOX JUNCTION BOX SIM SIMILAR TVP TVPICAL 11.N O. 11NLE5S NOTED OTHERWISE t# MOUNTINGHEIGHTABOVEFINISHEDFLOOR MC-# MAINCROSS-CONNECT TR-# TELECOMMUNICATIONSROOM SUGGESTED MATRIX OF RESPONSIBILITY FURNISHED INSTALLED ITEM: SHOWNON: BV: BV: NOTES: TECHNOLOGV ROUGH-IN, REFERTO T-SERIES EA. E.C. 3.4. GENERALTECHNOLOGVEpUIPMENT SCHEDULE ANO SPECIFICATIONS FOR DEFlNITION WPoRMATIONOUTLETFACEPLATES, T-SERIES LC. T.C. JACKS, AND TERMINATIONS CON�UITSLEEVES(WHENSHOWNON T-SERIES E.G E.C. DRAWINGS) CONDUIT SLEEVES (NOT SHOWN BUT N/A T.C. T.G 2.4. REQUIRED FOR PROPER INSTALLATION OF SVSTEM) TELECOMMIINICATION5V5TEMS T-SERIES E.Q E.C. 1. ROUGH-IN TELECOMMUNICATION E�UIPMENT, T-SERIES LC. T.C. CABLING. AND TERMINATIONS CABLETRAVQNCWDINGWIREBASKET T-SERIES E.G E.C. TRAY) REFER TO SPEQRCATION SECTION 2] 05 28 FOR oERNITION GROUN�ING LUGS ON TECHNOLOGV TSERIES T.Q EG 6. EQUIPMENT BONDINGSVSTEMFORTECHNOLOGV T-SERIES E.G E.C. ].8. SVSTEM, REFER TO SPECIFlCATION SECTION 2� OS 26 FOR DEFlNITION CONNECTIONOFTECHNOLOGY T-SERIES E.G E.C. BONDING SVSTEM TO THE ELECTRICAL GROUNOSVSTEM LME VOLTAGE POW ER (+12�V OR ESERIES EG EC. GREATER) LINEVOLTAGEPOWER(NOTSHOWN N/A T.G E.G 24. BUT REQUIRE� FOR PROPER INSTALLATION OF SVSTEM) LMEVOLTAGEPOWERFORDOOR ARCHSPEC EG EC. HAR�WARE POWER SUPPLIES LOW VOLTAGE CABLING FOR T-SERIES T.G T.C. TECHNOLOGV SVSTEMS CABLE HANGERS AND SUPPORTS OR TSERIES T.C. T.C. 5. OTHER CABLE ROUTING METHODS (OTHER THAN CONDUIT AND CABLE TRAV) TECHNOLOGVSERVICEENTRANCE TSERIES EG EC. CONDUITS, HANDHOLES, AND MANHOLES SUGGESTED MATRIX OF RESPONSIBILITY NOTES L LOCATIONS OF TELECOMMUNICATIONS ROUGH-INS SHALL BE INDICATED BV THE INFORMATION OUTLET SVM80L5 ON THE DRAW INGS. REFER TO THE TECHNOLOGV SVMBOL LIST FOR ADDITIONAL MFORMATION. 2. BASED ON THE INHERENT DIFFERENCES IN PRO�UCTS FROM VARIOUS MANUFACTURERS, ALL RW UIRED EQUIPMENT MAV NOT BE SHOW N ON THE DRAW INGS FOR ALL ACCEPTABLE MANUFACTURERS. 3. INCLUDES BACKBOXES AND CONDUIT REOUIRED FOR THE TECHNOLOGV SVSTEMS INSTALLATION. THE E.G SHALL BASE THE BID ON THE BASIS OF DESIGN SHOW N ON THE CONTRACTDOCUMENTS. 4. ALLCHANGESTOTHESLEEVES,BACKBOXES,CONDUITS,AN�POWERREQUIRE�BECAUSEOF THE T.C'S SELECTION OF AN ALTERNATE ACCEPTABLE MANUFACTURER OR FROM SVSTEM CONFIGl1RATIONS THAT ARE LEFT TO THE CHOICE OF THE CONTRACTOR SHALL BE INC W DED IN THE T.CS BIO. THIS BID SHALL INCLUDE INSTALLATION BY A LICENSED ELECTRICIAN. 5. UNLESS TRA�E RULES DICTATE OTHERW ISE. 6. FURNISHEO AS PART OF THE EQUIPMENT W HEN POSSIBLE, OR FURNISHED TO THE E G FOR MSTALLATION IN THE FlELD. ]. INCWDES ALL CONDUCTORS, GROUND BARS, AND TERMINATIONS FOR THE COMPLETE BONOING SVSTEM REQUIRED BY THE SPECIFICATIONS. 8. REFERTOELECTRICALDRAWINGSFORLOCATIONSOFPANELSANDSWITCHBOARDSSHOWN IN THE TECHNOLOGV BONDING RISER DIAGRAM AND TVPICAL TELECOM ROOM BONDWG FLOW DIAGRAM. TELECOM ROOM REFERENCES TELEGOM ROOM DETAILISHEET FLOORPLAN qRLX ROOM NUMBER REFERENCE REFERENCE TR-iG 1IT6-00 1/T3-1G PG1004 TECHNOLOGY GENERAL NOTES: 1. k#k-tWM INDICATESGENERALTECHNOLOGYEQUIPMENTSCHEDULEITEMLABELEDAS "EQUIPMENT LIST ABBREVIATION" 2. REFERTOGENERALTECHNOLOGVEQUIPMENTSCHEDULEANDSPECIFICATIONSFORFULL OESCRIPTIONS AND MANUFACTURERS OF ALL DEVICES. TECHNOLOGV MOUNTWG SUeSCRIPT KEV: A MOUNT AT+6" TO CENTERLINE ABOVE COUNTER OR BACKSPLASH H MOUNTORIENTEDHORIZONTALLV L MOUNTINCASEWORK M MOUNTINMODULARFURNITURE S MOUNT M SURFACE RACEWAY A SLASH IS USED BEPNEEN TWO SUBSCRIPTS, EG., AIH. TECHNOLOGY INSTALLATION NOTES: 1. THE COMPLETE INSTALLATION SHALL BE IN ACCORDANCE W ITH THE ADA STANDARDS PoR ACCESSIBLEDESIGN. REFERTOTHEADAGUIDELINESFORALLCONFIGURATIONDETAILS ON THIS PAGE FORADDITIONAL INFORMATION. 2. CONCEALALLCONDUITINWALLS,PARTITIONS,ABOVECEILING,INFLOORSLAB,ETC. UNLESSOTHERWISEINDICATEDONTHEPLANSORWTHESPECIFICATIONS. CONDUITIN MECHANICAL ROOMS AND STORAGE ROOMS W ITHOUT CEILINGS MAV BE EXPOSED ON BUILDING STRUCTURE. 3. BOXES LOCATED ON OPPOSITE SIDES OF NON-RATED WALLS SHALL BE OFFSET A MINIMUM OF 6" HOR¢ONTALLV. BOXES ON OPPOSITE SIDES OF RRE RATED WALLS SHALL BE OFFSETAMINIMUMOF24"HORIZONTALLY. "THRU-THEWALC'BOXESSHALLNOTBE ALLOW ED W ITHOl1T PRIOR W RITTEN APPROVAL OF THE ARCHITECTIENGINEER. 4. VERIFV ALL FURNITURE, MODULAR FURNITURE, AND E�UIPMENT LOCATIONS WITH ARCHITECTURALPLANS,ELEVATIONS,ANDREVIEWEDSHOPDRAWINGS. PRIORTOMAKING THE ACTUAL TELECOMMUNICATIONS W STALLATION, A�JUST OUTLETS OR CONNECTION LOCATIONS TO ACCOMMODATE FURNITURE AND/OR EQUIPMENT. 5. TELECOMMUNICATIONSEpUIPMENTSHALLBEMOUNTEDTOALLOWACCE55T0 ELECTRICALANDMECHANICALEpUIPMENT. ALLMOUNTINGOFTELECOMMUNICATION DEVICES ON E�UIPMENT SUPPLIED BV ANOTHER CONTRACTOR SHALL eE APPROVED IN ADVANCEBYTHEOTHERCONTRACTOR. 6. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL OPENINGS REQUIRED IN WALLS. ALL OPENINGS SHALL BE REPAIRED TO MATCH EXISTING BY A �UALIFlED CONTRACTOR AT THE EXPENSE OF THIS CONTRACTOR. ALL CON�UITS THROUGH WALLS SHALL BE GROUTED OR SEALED INTO OPEN W GS. 7. ALL MATERIALS USED TO SEAL PENETRATIONS OF FlRE RATED WALLS AND FLOORS SHALL BE TESTE� AND CERTIFlED AS A SVSTEM PER ASTM E814 STANDAR�S FOR FlRE TESTS OF THROUGH-PENETRATION FIRESTOPS. REFER TO DNISION ] FOR ADDITIONAL INFORMATION AND REQUIREMENTS SPEqFIC TO FIRESTOPPING. 8. REMOVEANDREINSTALLALLCEILINGTILESASREQUIREDFORTHEEXECUTIONOF TELECOMMUNICATIONS WORK THAT IS OUTSIDE THE CONTRACT LIMITS OF CONSTRUCTION. REPLACE CEILING TILES W ITH IDENTICAL MATERIAL W HERE DAMAGED BV THIS CONTRACTOR. 9. ALLCAeLETRAVSIZESAREAS�EFINEDONTHE�RAWINGS.REFERTOSPECIFICATION SECTION 2] 11 00 FOR APPROVED MANUFACTURERS AND INSTALLATION RE�UIREMENTS. iQ FWSHMOUNTALLTELECOMMUNICATIONOUTLETSAT+18"FROMFLOOR(CENTERLME �IMENSION), EXCEPT WHERE OTHERWISE NOTED.Ol1TLETS MAV BE SURFACE MOUNTED WHEN CONDUIT IS SPECIFIED EXPOSED. 11. INSTALLALL LOW VOLTAGE CABLING IN CONDUIT WITHIN THE GARAGE. ROUTE CONOUITTO TELECOMMUNICATION ROOM. TECHNOLOGY OUTSIDE PLANT NOTES 1. THE LOCATION OF THE CONDUIT AND HAND HOLES SHOWN ARE APPROXIMATE LOCATIONS. RELD VERIFY THE LOCATION OF ALL UTILITIES PRIVATE ANDIOR PUBLIC PRIOR TO THE WSTALLATION OF THE COMPONENL FlELD COORDINATE THE FINAL LOCATION WITH THE OWNER AND ENGINEER PRIOR TO INSTALLATION. 2. POTHOLINGTOLOCATEEXISTINGUNDERGROUNOUTILITIES,IFAPPLICABLE,SHALLBE W C W DED IN THE CONTRACTOR'S BID. CONTRACTOR IS RESPONSIBLE FOR FINAL PLACEMENT OF HANDHOLES AND SHALL NOTIFY THE ENGWEER OF FlNAL LOCATIONS PRIOR TO INSTALLATION. 3. HANO HOLES SHALL BE CONSTRUCTED 50 THAT THE TOP OF THE FRAME W ILL BE FWSH WITH THE GROUND LWE. 4. REMOVAL AND REPLACEMENT OF THE EXISTING UNDERGROUND UTILITIES THAT ARE REQUIRED TO COMPLETE THE INSTALLATION SHALL BE INCWDED IN THE CONTRACTOR'S BID. S CONTRACTOR SHALL INCLUDE IN THEIR BID ANV REMOVAL AND REPLACEMENT OF EXISTING SIDEWALK, PAVEMENT, GRASS, SHRUBS, TREES, ETC. THAT WILL BE IMPACTED BV THE INSTALLATION OF THE NEW CONDUITS SHOWN ON THE DRAWINGS. IF TREES ARE REQUIRED TO BE REMOVED THE CONTRACTOR SHALL CONTACT THE OW NER AND DISCUSS OPTIONS PRIOR TO CUTTING DOW N ANV TREE OR SHRUB OVER 5' IN HEIGHT. 6. NO ADDITIONAL COST SHALL BE APPROVED FOR PLACING CON�UITS DEEPER THAN REQUIRED MINIMUM DEPTH. ]. PROVIDE A MINIMUM OF 15'-0" SLACK LOOP W ITHIN EACH HAND HOLE. SLACK LOOP SHALL BE SECURE SO COPPER OR FlBER IS NOT RESTING ON EARTH AFTER FINAL INSTALLATION. TECHNOLOGY SHEET INDEX TO-00 TECHNOLOGYCOVERSHEET Ti-00 TECHNOLOGYSITEPLAN T3-iG FIRSTFLOORPLAN-TECHNOLOGV T3-2G SECON�FLOORPLAN-TECHNOLOGV T3-3G THIRDFLOORPLAN-TECHNOLOGV T3-4G FOURTHFLOORPLAN-TECHNOLOGV T6-00 TECHNOLOGYROOMENLARGEMENTS T]-00 TECHNOLOGY RISER OIAGRAMS T8-00 TECHNOLOGYDETAILS T840 TECHNOLOGYDETAILS T9-00 TECHNOLOGV SCHEDULES ArchitecNre I Engineering I Interior Design 1�15 Magnavox Way I 930 Nohh Mentlian Fort Wayne, IN 46804 Intlianapolis, IN 46204 260.432.9337 31].917.1190 wwwmskitlmm <:IMEG 8900 KEVSTONE XING SUITE 210 INDIANAPOLIS, IN 46240 31�.848.5045 FAX:31�.8442201 www.imegcorp.com L � � a 'o � Q . U �/� U it� �` O W W^, � � L � �� � U`' � O ^ •� � w � � A 1 _ U 00 � �� • -` U �% � +� � � � � �U � � � � � a� �o � o � �U PROJECTNO. DATE 18004130.00 12-12-19 REV. SET DESCRIPTION BP #4.1 - Arch/MEPT/ Garage Documents � d RELEA5E0 FOR CONSTRUCTION Suhjec� �o compliance with all regula�ions 04 S�a�e antl Local Codes City of Carmel � y�n„� ��.�a,�,a' � onrE: 06/11 /20 70" MAX. 10"-24" MAX. INSTALLABOVECOUNTER INSTALLABOVECOUNTER WSTALL�EVICEATIB" WSTALLDEVICEAT44" WSTALLDEVICEAT42" DEVICEAT44"ABOVE DEVICEAT40"ABOVE ABOVEFINISHEDFLOOR. ABOVEFINISHEDFLOOR. ABOVEFINISHEDFLOOR. FINISHED FLOOR. FINISHED FLOOR. ADA GUIDELWES - FRONT ACCESS ADA GUIDELINES - SIDE ACCESS ADA STANDARDS FOR ACCESSIBLE DESIGN SHEET TITLE TECHNOLOGY COVERSHEET SHEETNUMBER TO-00 �.,. ....�� 12�12�19 DATE MSKTD & Associates