HomeMy WebLinkAboutaddendum 3_with attachments - BP #4 (revised 12.16.19)Page 1 of 1 ADDENDUM NO. 3 FRANCISCAN ORTHOPEDIC CENTER OF EXCELLENCE BID PACKAGE NO. 4 - GARAGE/BRIDGE STRUCTURAL PACKAGE MSKTD Project No. 7382 December 12, 2019 This addendum is issued as a supplement to the drawings and specifications and shall be considered an integral part of the same. ITEM LOCATION DESCRIPTION 3.1 WGI See attached Addendum #3 items from WGI. Respectfully submitted, MSKTD & ASSOCIATES, INC. D. Nicholas Slater, Architect DNS/lw Attachments: Addendum #3 from WGI cc:Martin Roesli (Martin.Roesli@tonnandblank.com) Mark Rogers (mark.rogers@tonnandblank.com) Daryl Humble (daryl.r.humble@imegcorp.com) Susan Smith (Susan.K.Smith@imegcorp.com) Jaclyn Hensel (jhensel@cripe.biz) Alyssa Prazeau (aprazeau@context-design.com) Doug Gannon (Doug.Gannon@wginc.com) JD Taylor (jdtaylor@cesolutionsinc.com) DNS/RJH/File ARCHITECTURE ENGINEERING INTERIOR DESIGN 1715 MAGNAVOX WAY, FORT WAYNE, INDIANA 46804 PH. 260-432-9337 930 NORTH MERIDIAN, INDIANAPOLIS, INDIANA 46204 PH. 317-917-1190 WWW.MSKTD.COM BP4 ADDENDUM-3 Project: Franciscan Orthopedic Center of Excellence Location: Carmel, Indiana WGI Project #: 23183655.00 Owner: Franciscan Health, Inc. Contractor: Tonn and Blank Construction The Contractor is hereby directed to make the change(s) to the Contract Documents as described herein. GENERAL DESCRIPTION:Updated structural drawings. PERTAINING TO SPECIFICATIONS No Changes PERTAINING TO DRAWINGS ITEM # D1:Replace Drawing AP101, LEVEL 1 PLAN – ARCHITECTURAL PARKING ∂ Revised rooms below ramp as indicated. ITEM # D2:Replace Drawing S-101, LEVEL 1 PLAN - STRUCTURAL ∂ Revise Revised rooms below ramp as indicated. ITEM # D3:Replace Drawing S-201, BUILDING ELEVATIONS - STRUCTURAL ∂ Revised bottom of steel channels and removed lowest WT connections at detail 3/S-201 West Framing Elevation - Structural. ITEM # D4:Replace Drawing S-401, ENLARGED SOUTH TOWER PLANS - STRUCTURAL ∂ Revised details 2-4 for stair layout, removed window openings and revised door location in wall on grid P4.4 and revised opening locations in wall on grid PE. ITEM # D5:Replace Drawing S-402, ENLARGED SOUTH TOWER PLANS - STRUCTURAL ∂ Revised detail 1 for stair layout, removed window openings and revised door location in wall on grid P4.4 and revised opening locations in wall on grid PE. ITEM # D6:Replace Drawing S-421, ENLARGED PLANS – STRUCTURAL ∂ Revised rooms below ramp as indicated. ITEM # D7:Replace Drawing S-522, PCC FRAMING DETAILS – STRUCTURAL ∂ Revised rooms below ramp as indicated. FE FESTOPSTOPP1 PD PC PB PA PA.3 PA.2 P2 P3 P4 P5 P6 P7 P8P7.8P1.2 P4.4 PE 11'-3"34'-0"48'-0"36'-0"14'-11"12'-6"8'-7"6'-0"30'-0"48'-0"35'-0"11'-3"1'-0" 36'-0"36'-0"45'-3"46'-3"57'-9 1/2"P1-A P2-A V15-BV15-BP3-A P1-A P1-A P1-A P1-A P1-AP6-BP7-BV11-BP5-BP7-BV10-BP4-BV18-BP6-BV20-BV11-BP7-BP6-BP5-BP6-C P5-CV16-BV14-CV4-C V12-BV14-C R4-A R4-A R4-A R4-A R4-A R4-A R4-A R1-D R2-A R1-DR2-DR1-DR1-D R1-AR1-D R2-A V8-C R1-A V14-CV4-C V5-C E2-F E4-E E1-F E3-E E2-F E4-E E1-F E3-EV8-BV13-C V17-C R4-A R7-A R7-A R7-A R7-A R7-A R7-A R6-DR7-DR7-DR7-DR7-DR7-A R7-DR7-D R7-AR5-A R3-A R8-A R8-AR9-AIT/DATA ELECTRICAL MAINTENANCE BIKE ROOM B3-AB4-AB5-AB6-AR1-D R1-D AP401 1 AP401 5 R6-A P4.8 SIGN LOCATED ABOVE R4 SIGN SIGN LOCATED ABOVE R4 SIGN SIGN LOCATED ABOVE R4 SIGN R1-D R1-DR1-D R1-AR1-D REFER TO NOTE 2, TYP REFER TO NOTE 2, TYP REFER TO NOTE 3, TYP REFER TO NOTE 3, TYPREFER TO NOTE 4, TYP REFER TO NOTE 4, TYP REFER TO NOTE 5, TYP REFER TO NOTE 6, TYP REFER TO NOTE 6, TYP SIGN LOCATED ABOVE R4 SIGN P5.2 P7.1 REFER TO NOTE 7, TYP V19-C V8-C SIGN LOCATED ABOVE R4 SIGN R8-A1'-10"8'-0" REFER TO AP102 FOR CONTINUATION (22) SPACES @ 9'-0" = 198'-0" 3'-6" 5'-6"8'-0" REFER TO AP102 FOR CONTINUATION (21) SPACES @ 9'-0" = 189'-0" 9'-0" TYP 18'-0" TYP9'-0" TYP 18'-0" TYP(4) SPACES @ 9'-0" = 36'-0"8'-0"1'-10" 3'-6" (3) SPACES @ 9'-0" = 27'-0"8'-0"1'-10" 3'-6"(13) SPACES @ 9'-4" = 121'-4"18'-0" TYP 9'-0" TYP7 5° (26) SPACES @ 9'-4" = 242'-8"4'-10"9'-0"9'-0"5'-7"18'-0" TYP9 '-0 " T Y P75°12'-6"12'-6"17'-0"11'-1"7'-5"(21) SPACES @ 9'-4" = 196'-0"8'-3"6'-4" 5'-4"18'-0" TYP9'-0" TYP 7 5 °(8) SPACES @ 9'-0" = 72'-0"(4) SPACES @ 9'-4" = 37'-4"4'-10"9'-0"9'-0"5'-6"18'-0" TYP9'-0" TYP7 5°9'-0" TYP18'-0" TYP 12'-0"12'-0" 1'-0" R 5' - 0 "R 5' - 0"10'-3"8'-3"(20) SPACES @ 9'-4" = 186'-8"7'-5"2'-9"10'-3"8'-3"8'-3"5'-2"8'-3"8'-3"5'-2"8'-3"8'-3"8'-3"8'-3"8'-3"13'-6"8'-3"8'-3"8'-3"8'-3"8'-3"4'-2"9'-3"8'-3"5'-2"8'-3"8'-3"5'-2"8'-3"18'-0" TYP75°18'-0" TYP9'-0" TYP 7 5 °EQEQUP DN 3'-6"1'-10"2'-9"B2-H SP SP SP SP SP SP SP SP SP SP EQ EQ EQ EQ EQ 2 1/2"REFER TO NOTE 8, TYP 18'-8"5'-6"5'-6"5'-6"5'-6"2'-1 1/2"R8-HR9-HR5-A 18'-0"12'-9 1/2"18'-0"180'-9"20'-0"1'-2 1/2"57'-9 1/2"62'-0"37'-0"6'-4"14'-5 1/2"1'-11 1/2"297'-6"V20-BV20-BV20-BV10-BV20-C V20-C V21-AV21-AV21-AV21-ASIGN LOCATED ABOVE R4 SIGNV9-BV9-BV20-BV20-BSP SP SPACE TABULATION LEVEL STANDARD COMPACT ADA ADA VAN TOTAL 4 144 9 0 0 153 3 158 9 8 2 177 2 158 9 8 2 177 1 132 8 14 3 157 TOTAL 592 35 30 7 664 XXX-X SP SHEET NOTES: NO SYMB NOTE 1 REPRESENTS PLAN MATCH LINE. 2 PARKING SPACE STRIPING TO BE 4" WIDE TRAFFIC YELLOW OR WHITE STRIPING, REFER TO STRIPING KEY PLANS ON SHEET AP501. WHITE PARKING SPACE STRIPING INDICATES VISITOR SPACES AND YELLOW PARKING SPACE STRIPING INDICATES EMPLOYEE. SINGLE LINE CONFIGURATION WILL BE USED FOR ALL PARKING SPACE STRIPING. ALSO REFER TO SHEET AP501 FOR ADDITIONAL STRIPING INFORMATION. 3 CROSS HATCH STRIPING TO BE 4" WIDE TRAFFIC YELLOW STRIPING AT 24" OC WITH BACK-ROLLED SLIP-RESISTANT ADDITIVE AS SHOWN IN PLANS, REFER TO SHEET AP501 FOR ADDITIONAL INFORMATION. 4 DIRECTIONAL ARROWS TO BE PAINTED TRAFFIC YELLOW WITH BACK-ROLLED SLIP-RESISTANT ADDITIVE AS SHOWN ON PLANS, REFER TO SHEET AP501 FOR ADDITIONAL INFORMATION. 5 PAVEMENT GRAPHICS TO BE PAINTED AS SHOWN ON PLANS WITH BACK-ROLLED SLIP-RESISTANT ADDITIVE, REFER TO SHEET AP501 FOR ADDITIONAL INFORMATION. 6 REPRESENTS SIGN MARK AS DEFINED ON SIGN LEGEND. THE LETTER AFTER THE DASH (-) REPRESENTS THE MOUNTING DETAIL, REFER TO SIGN MOUNTING LEGEND. SIGN TO BE PLACED APPROXIMATELY AS SHOWN ON PLANS. REFER TO DETAIL 11/AP521 FOR ADDITIONAL INFORMATION. 7 REPRESENTS A PRECAST BOLLARD, REFER TO 14/S-551. 8 REPRESENTS A STEEL BOLLARD, REFER TO 15/S-551. 9 ALL SIGNS LOCATED AT ENTRY/EXIT SHALL BE CENTERED IN LANES, TYPICAL. 10 UNDERSIDE OF ALL CONCRETE FLOOR SLABS SHALL RECIEVE WHITE CONCRETE STAIN. AREA TO INCLUDE ALL BEAM & GIRDER SIDES & BOTTOM AS WELL AS COLUMN SURFACE DOWN TO THE LOWEST BEAM OR GIRDER DEPTH. REFER TO SPEC SECTION 09 91 00 FOR ADDITIONAL INFORMATION. 11 INDICATES STAND PIPE. ALL VERTICAL RISERS FOR PLUMBING, ELECTRICAL AND MECHANCIAL SYSTEMS SHALL BE PROTECTED BY STEEL PIPE GUARDS, REFER TO DETAILS 8 & 9/S-551. REFER TO MECH. DRAWINGS FOR PIPE LOCATIONS. SIGN LEGEND ENTRY-EXIT SIGNS DET NO.SPEC TYPE E1 ENTER 7/AP521 E E2 EXIT 7/AP521 E E3 8'-2" CLEARANCE 8'-2" 12/AP511 D E4 (DNE) DO NOT ENTER (DNE) 13/AP511 D VEHICULAR SIGNS DET NO.SPEC TYPE V1 (NL) | Park → 1/AP512 A V2 (NL) | Exit → 2/AP512 A V3 Park → | Exit → 3/AP512 A V4 ↑ Exit 4/AP512 A V5 ↑ Park → 5/AP512 A V6 ↑ Park 6/AP512 A V7 Exit → 7/AP512 A V8 (DNE) DO NOT ENTER (DNE) 8/AP512 A V9 ↓ Two Way Traffic ↑ 9/AP512 A V10 ↑ One Way Traffic ↑ 10/AP512 A V11 Wrong Way 11/AP512 A V12 (PED) CAUTION: Watch for Peds (PED) 12/AP512 A V13 (NL) | Park ↑ 13/AP512 A V14 ← Park 14/AP512 A V15 ← Exit | (NR) 15/AP512 A V16 ← Park | ← Exit 16/AP512 A V17 Park → 17/AP512 A V18 (ST) | ← Park | Exit → | (ST) 18/AP512 A V19 ↑ (ADA) → 27/AP512 A V20 Yellow Striping... 18/AP513 A V21 Yellow Striping… 16/AP513 C PEDESTRIAN SIGNS DET NO.SPEC TYPE P1 Level X 23/AP512 C P2 → Level Y | Level X ← 25/AP512 C P3 ← Level Y | Level X → 26/AP512 C P4 Stair 19/AP512 B P5 To Hospital → 20/AP512 B P6 ← To Hospital 21/AP512 B P7 ↑ To Hospital 22/AP512 B P8 Level X - Skywalk at Level 4 24/AP512 C P9 ↑ Skywalk to Hospital ↑ 28/AP512 B REGULATORY SIGNS DET NO.SPEC TYPE R1 ADA 1/AP513 F R2 ADA VAN 2/AP513 F R3 No Parking 3/AP513 F R4 Compact Space 4/AP513 C R5 Reserved Parking → 5/AP513 C R6 Reserved Parking ← 6/AP513 C R7 Reserved Parking ←→ 7/AP513 C R8 Caution: No Peds…in Lanes 8/AP513 C R9 Live Load Sign 9/AP513 C R10 Level Egress Sign - This Level… 10/AP513 C R11 Level Egress Sign - Down… 11/AP513 C R12 You are Here 12/AP513 G R13 Stair (Graphic-Braille) 13/AP513 G R14 Exit Stair (Graphic-Braille) 14/AP513 G R15 In Case of Fire… 15/AP513 C BUILDING SIGNS DET NO.SPEC TYPE B1 Elevator (Braille) 19/AP513 G B2 Bike Room (Braille) 19/AP513 SIM G B3 IT/Data (Braille) 19/AP513 SIM G B4 Electrical (Braille) 19/AP513 SIM G B5 Mechanical (Braille) 19/AP513 SIM G B6 Maintenance (Braille) 19/AP513 SIM G SYMBOL LEGEND DET NO. (DNE)DO NOT ENTER 2/AP511 (NL) NO LEFT TURN 3/AP511 (NR) NO RIGHT TURN 4/AP511 (ST) STOP 5/AP511 (PED) PEDESTRIAN CROSSING 6/AP511 (ADA) ADA SYMBOL 7/AP511 SIGN MOUNTING LEGEND DETAIL NO. A WALL/COLUMN MOUNT 1/AP521 B TEE STEM MOUNT 2/AP521 C SWING FRAME MOUNT 3 & 4/AP521 D SPANDREL POST MOUNT 5/AP521 E CLEARANCE BAR 6/AP521 F ALUMINUM LETTERS 7/AP521 G LIGHT POLE MOUNT 8 & 9/AP521 H CHAIN LINK MOUNT 10/AP521 COLOR CHART LEVEL SIGN BACKGROUND SIGN COPY 4 BLUE WHITE 3 GREEN WHITE 2 PURPLE WHITE 1 RED WHITE SIGNAGE IS INCLUDED FOR INFORMATION ONLY AND IS NOT PART OF THIS BID PACKAGE True North MOB HOSPITAL B SKYBRIDGE PARKING GARAGE A C Architecture | Engineering | Interior Design 1715 Magnavox Way Fort Wayne, IN 46804 260.432.9337 930 North Meridian Indianapolis, IN 46204 317.917.1190 www.msktd.com SHEET TITLE SHEET NUMBER SET DESCRIPTION BP #4 - Garage / Bridge Structural Package PROJECT NO. DATE MSKTD & Associates KEY PLAN 12/16/2019 12:54:25 PMLEVEL 1 PLAN - ARCHITECTURAL PARKING AP101 Carmel, IndianaFranciscan OrthopedicCenter of Excellence7382 10/11/2019NEW PARKING STRUCTUREEL 100'-3" LEVEL 1 EL 111'-7" LEVEL 2 EL 122'-11" LEVEL 3 EL 134'-3" LEVEL 4 ISOMETRIC VIEW NORTH 1/16" = 1'-0"1 LEVEL 1 PLAN - ARCHITECTURAL PARKING 1 REV. DATE 1 BP4 ADDENDUM 3 12/11/2019 P1 PD PC PB PA PA.3 PA.2 P2 P3 P4 P5 P6 P7 P8P7.8P1.2 P4.4 PE 11'-3"34'-0"48'-0"36'-0"14'-11"12'-6"8'-7"6'-0"30'-0"48'-0" 1'-0" 34'-0"11'-3"1'-0" 36'-0"36'-0"45'-3"46'-3"57'-9 1/2"UP DN 1 S-301 1 S-301 2 S-301 2 S-301 FD FD FDFD TD P4.8 3'-6"3'-6"11'-6 1/4"11'-6 5/8"11'-6 5/8"11'-6 5/8"1 S-501 2 S-501 TYP 1 S-501 2 S-501 TYP 1 S-501 2 S-501 TYP 3 S-501 3 S-501 S-501 6 TYP S-501 8 TYP 5" CONCRETE SLAB-ON-GRADE, REFER TO SHEET NOTES 9 & 10 5" CONCRETE SLAB-ON-GRADE, REFER TO SHEET NOTES 9 & 10 5" CONCRETE SLAB-ON-GRADE, REFER TO SHEET NOTES 9 & 10 100'-1 1/2" 99'-11"100'-3" 99'-11"100'-3"100'-1"100'-3"99'-11"100'-2" 99'-11" 100'-0 1/2" 100'-2" 99'-11 3/4"100'-1 1/8" 99'-8"98'-10"99'-8"99'-8"99'-0" 98'-10" 99'-0"99'-8" 101'-6"103'-6"105'-6" 99'-8"98'-10"99'-8" 98'-10" S-401 2 S-411 2 S-421 2 96'-6" 96'-6" TYP UNO 96'-9" 4'-0" 4'-0"4'-0"PCC BOLLARD, REFER TO DET 14/S-551, TYP 5 S-502 4 S-502 4 S-502 5 S-502 4 S-502 4 S-502 5 S-502S-501 9 TYP P5.2 P7.1 FD FD FD FD 100'-1" 100'-3" 100'-1" 100'-3"99'-11" 99'-8"99'-0"99'-0"99'-8" 101'-6"103'-6"105'-6" 100'-1" TO WASH 99'-4" TO WASH 99'-4" 100'-1 3/8"20'-0"20'-0"6 S-502 7 S-502 6 S-502 7 S-502 6 S-502 6 S-502 7 S-502 6 S-502 7 S-502 6 S-502 SP SP SP SP SP SP SP SP SP SP 8 S-502 9 S-502 100'-1 1/2" 100'-1 1/2" TO FF EL6'-0"3'-0"20'-8"15'-4"3'-0" PROVIDE SOG REINF #4 @ 12" OC EW FOR AREA BOUNDED BY GRIDS PB-PC/P2-P5.73'-4" RO2'-5"TD 7 S-501 SIM 4'-5"25'-0"16'-10"180'-9"20'-0"1'-2 1/2"57'-9 1/2"62'-0"37'-0"6'-4"14'-5 1/2"1'-11 1/2"SP SP 297'-6" STEEL BOLLARD, REFER TO 15/S-551 TYP FD SP SHEET NOTES: NO SYMB NOTE 1 COORDINATE ALL DIMENSIONS, DETAILS, FINISHES, TIE HOLE LOCATIONS, AND BLOCKOUTS/SLEEVES WITH ALL OF THE PROJECT CONSULTANT DRAWINGS. 2 INDICATES PLAN MATCH LINE. 3 FOR GENERAL NOTES, REFER TO SHEETS S-001 AND S-002. 4 FOR EXPLANATION OF NOTATIONS AND ABBREVIATIONS, REFER TO SHEET S-002. 5 100'-0" = ELEVATION RELATIVE TO DATUM 6 FLOOR ELEVATIONS AS INDICATED DESIGNATE TOP OF CONCRETE SLAB AT COLUMN CENTER LINES. ELEVATIONS DO NOT INCLUDE CONCRETE WASHES, BEAMS, CURBS, ETC. FOR PLAN ELEVATION, REFER TO 1, 2, & 3/S-551 7 FOR FLOOR ELEVATIONS BETWEEN POINTS INDICATED, USE STRAIGHT LINE INTERPOLATION. 8 FOR COLUMN DETAILS, REFER TO SHEET S-511. ALL COLUMNS ARE CENTERED ON GRID LINES UNLESS NOTED. 9 SLAB-ON-GRADE SHALL BE A MINIMUM OF 5" THICK CONCRETE OVER 6" (MIN) COMPACTED GRANULAR SUB-BASE. 10 REFER TO SHEET S-501 FOR SLAB-ON-GRADE DETAILS. 11 INDICATES FLOOR DRAIN, REFER TO DETAIL 6 & 7/S-501. FOR ADDITIONAL INFORMATION REFER TO MECHANICAL DRAWINGS. SLOPE SLAB TO DRAIN. 12 REFER TO MECHANICAL DRAWINGS FOR DRAIN AND PIPE SIZES. NO PIPING SHALL BE INSTALLED WITH LESS THAN 8'-4" CLEARANCE UNLESS IT IS IMMEDIATELY ADJACENT TO A WALL OR COLUMN WHERE IT CANNOT BE HIT BY A VEHICLE. 13 CONTRACTORS SHALL INCLUDE IN THEIR BIDS ALL NECESSARY ALLOWANCES FOR HOT AND COLD-WEATHER CONCRETING (INCLUDING BUT NOT LIMITED TO NIGHT POURS, EVAPORATION REDUCTION, HEATING, BLANKETING, CONCRETE ADMIXTURES ETC) TO COMPLETE THE PROJECT AS SCHEDULED. REFER TO SPECIFICATION SECTION 033020. 14 PROVIDE 1" GAP BETWEEN ALL WALLS AND COLUMNS, REFER TO DETAIL 18/S-501 UNLESS NOTED OTHERWISE. 15 FOR SEALANT, DECK COATING, AND EXPANSION JOINT DETAILS, REFER TO SHEET S-541. 16 INDICATES STAND PIPE. ALL VERTICAL RISERS FOR PLUMBING, ELECTRICAL AND MECHANCIAL SYSTEMS SHALL BE PROTECTED BY STEEL PIPE GUARDS, REFER TO DETAILS 5 & 6/S-551. REFER TO MECH. DRAWINGS FOR PIPE LOCATIONS. 17 REFER TO AP DRAWINGS FOR BOLLARD LAYOUT. SEE SHEET S-551 FOR BOLLARD ATTACHMENT DETAILS. 18 ALL CRACKS THAT APPEAR IN SOG AND SUPPORTED SLAB SHALL BE ROUTED & SEALED, REFER TO DETAILS 1 & 2/S-541. True North MOB HOSPITAL B SKYBRIDGE PARKING GARAGE A C Architecture | Engineering | Interior Design 1715 Magnavox Way Fort Wayne, IN 46804 260.432.9337 930 North Meridian Indianapolis, IN 46204 317.917.1190 www.msktd.com SHEET TITLE SHEET NUMBER SET DESCRIPTION BP #4 - Garage / Bridge Structural Package PROJECT NO. DATE MSKTD & Associates KEY PLAN 12/16/2019 12:54:29 PMLEVEL 1 PLAN - STRUCTURAL S-101 Carmel, IndianaFranciscan OrthopedicCenter of Excellence7382 10/11/2019NEW PARKING STRUCTURENORTH 1/16" = 1'-0"1 LEVEL 1 PLAN - STRUCTURAL EL 100'-3" LEVEL 1 EL 111'-7" LEVEL 2 EL 122'-11" LEVEL 3 EL 134'-3" LEVEL 4 ISOMETRIC VIEW 1 REV. DATE 1 BP4 ADDENDUM 3 12/11/2019 Level 1 100' -3" Level 2 111' -7" Level 3 122' -11" Level 4 134' -3" P1P2P3P4P5P6P7P8P7.8 P1.2P4.4P4.8 TO SPANDREL 138'-0" TO SPANDREL 126'-8" TO SPANDREL 115'-4" TOW 104'-0" P5.2P7.1 11'-3"34'-0"48'-0"36'-0"14'-11"12'-6"8'-7"6'-0"30'-0"48'-0" 1'-0" 34'-0"11'-3" TOW 150'-11 1/2", TYP AT STAIR TOWER TO CHANNEL 141'-1", TYP TO WT 135'-3 1/2", TYP TO WT 123'-11 1/2", TYP TO WT 112'-7 1/2", TYP TO WT 102'-7", TYP BO CHANNEL 101'-1", TYP 2'-0" 3'-0"4'-0"4'-0"4'-0"4'-0"4'-0"4'-0"4'-0" 2'-0"2'-0" 4'-0"4'-0"4'-0"4'-0"4'-0"4'-0"4'-0"4'-0"4'-0"4'-0"4'-0" 2'-0"2'-0" 4'-0"4'-0"4'-0"4'-0"4'-0"4'-0"4'-0"4'-0" 2'-0"2'-0" 4'-0"4'-0"4'-0"4'-0"4'-0"4'-0"4'-0"4'-0" 2'-0"2'-0" 4'-0"4'-0"4'-0"4'-0"4'-0"4'-0"4'-0"4'-0" 2'-0"2'-0" 4'-0"4'-0"4'-0"4'-0"4'-0"4'-0"4'-0"4'-0"4'-0"4'-0"4'-0" 2'-0"2'-0" 4'-0"4'-0"4'-0"4'-0"4'-0"4'-0"4'-0"4'-0"3'-3"4'-0"4'-0" BO CHANNEL 109'-1" BO CHANNEL 109'-1" REFER TO DET 9/S-521 FOR TYP FRAMING & CONN Level 1 100' -3" Level 2 111' -7" Level 3 122' -11" Level 4 134' -3" P1 P2 P3 P4 P5 P6 P7 P8P4.4 P4.8 TO SPANDREL 138'-0" TO SPANDREL 126'-8" TO SPANDREL 115'-4" TOW 104'-0" P5.2 P7.1 45'-3"48'-0"36'-0"14'-11"12'-6"8'-7"6'-0"30'-0"48'-0" 1'-0" 45'-3" TOW 150'-11 1/2", TYP AT STAIR TOWER CONT SPANDREL THRU COLUMN, TYP AT P5.2 TO CHANNEL 141'-1", TYP TO WT 135'-3 1/2", TYP TO WT 123'-11 1/2", TYP TO WT 112'-7 1/2", TYP TO WT 102'-7", TYP BO CHANNEL 101'-1", TYP BO CHANNEL AT CANOPY 112'-1" REFER TO DET 10/S-521 FOR TYP FRAMING & CONN TO WT AT CANOPY 113'-7" 6"4'-2"3'-0"4'-0"3'-0"4'-0"3'-0"4'-0"3'-0"4'-0"3'-0"4'-0"3'-0"2'-7" 1'-7" 2'-10"4'-0"3'-0"4'-0"3'-0"4'-0"3'-0"4'-0"3'-0"4'-0"3'-0"4'-0"3'-0" 1'-7" 2'-5"3'-0"4'-0"3'-0"4'-0"3'-0"4'-0"3'-0"4'-0"3'-0"2'-7" 5" 1'-10"4'-0"3'-0"4'-0"3'-0"4'-0"3'-0"4'-0"3'-0"4'-0"3'-0"4'-0"3'-0"2'-5" 1'-7" 2'-10"4'-0"3'-0"4'-0"3'-0"4'-0"3'-0"4'-0"3'-0"4'-0"3'-0"4'-0"3'-0" 1'-7" 2'-5"3'-0"4'-0"3'-0"4'-0"3'-0"4'-0"3'-0"3'-7"5" BO CHANNEL AT CANOPY 112'-1" TO WT AT CANOPY 113'-7" Level 1 100' -3" Level 2 111' -7" Level 3 122' -11" Level 4 134' -3" PDPCPBPAPA.2 TO SPANDREL 138'-0" TO SPANDREL 126'-8" TO SPANDREL 115'-4" TOW 104'-0" 14'-5 1/2"43'-4"62'-0"57'-9 1/2" TO CHANNEL 141'-1", TYP TO WT 135'-3 1/2", TYP TO WT 123'-11 1/2", TYP TO WT 112'-7 1/2", TYP TO WT 102'-7", TYP BO CHANNEL 101'-1", TYP 8 1/2"4'-0"3'-0"4'-0"2'-9" 1'-6" 4'-4"4'-0"4'-0"4'-0"4'-0"4'-0"4'-0"4'-0"4'-0"4'-0" 1'-6"2'-6" 4'-0"4'-0"4'-6"4'-0"4'-6"4'-0"4'-0"4'-0"4'-0"4'-0"4'-0"4'-6"4'-6"4'-0" 1'-6" 3'-0"4'-0"4'-0"4'-6"4'-6"4'-0"4'-0"4'-0"4'-0"4'-6"4'-0"4'-6"4'-0"4'-0"9 1/2" BO CHANNEL 109'-1", TYP REFER TO DET 9/S-521 FOR TYP FRAMING & CONN Level 1 100' -3" Level 2 111' -7" Level 3 122' -11" Level 4 134' -3" PD PC PB PAPA.3 PA.2 TO SPANDREL 138'-0" TO SPANDREL 126'-8" TO SPANDREL 115'-4" TOW 104'-0" 57'-9 1/2"62'-0"37'-0"6'-4"14'-5 1/2" TOW 150'-11 1/2", TYP AT STAIR TOWER TO CHANNEL 141'-1", TYP TO WT 135'-3 1/2", TYP TO WT 123'-11 1/2", TYP TO WT 112'-7 1/2", TYP TO WT 102'-7", TYP BO CHANNEL 101'-1", TYP 9 1/2"4'-0"4'-0"4'-6"4'-0"4'-6"4'-0"4'-0"4'-0"4'-0"4'-6"4'-6"4'-0"4'-0"3'-0" 1'-6" 4'-0"4'-6"4'-6"4'-0"4'-0"4'-0"4'-0"4'-0"4'-0"4'-6"4'-0"4'-6"4'-0"4'-0" 2'-6"1'-6" 4'-0"4'-0"4'-0"4'-0"4'-0"4'-0"4'-0"4'-0" 2'-0" 1'-6" REFER TO DET 9/S-521 FOR TYP FRAMING & CONN S-201 5 Level 4 134' -3" PD 9'-7"9'-7"1'-1"1'-8"7"2'-1"4"1"2"2" HSS8X6X1/2 POST, REFER TO 6/S-523 FOR ADDL INFO SNOW GATE FRAME, REFER TO 1 & 2/S-523 HSS4X4X1/4 POST, REFER TO 5/S-523 FOR ADDL INFO HSS4X4X1/4 POST, REFER TO 5/S-523 FOR ADDL INFO 9 1/2"4'-0"4'-0"4'-6"4'-0"4'-6" 4"4" Architecture | Engineering | Interior Design 1715 Magnavox Way Fort Wayne, IN 46804 260.432.9337 930 North Meridian Indianapolis, IN 46204 317.917.1190 www.msktd.com SHEET TITLE SHEET NUMBER SET DESCRIPTION BP #4 - Garage / Bridge Structural Package PROJECT NO. DATE MSKTD & Associates 12/16/2019 12:54:37 PMBUILDING ELEVATIONS - STRUCTURAL S-201 Carmel, IndianaFranciscan OrthopedicCenter of Excellence7382 10/11/2019NEW PARKING STRUCTURE3/32" = 1'-0"1 NORTH FRAMING ELEVATION - STRUCTURAL 3/32" = 1'-0"2 SOUTH FRAMING ELEVATION - STRUCTURAL 3/32" = 1'-0"3 WEST FRAMING ELEVATION - STRUCTURAL 3/32" = 1'-0"4 EAST FRAMING ELEVATION - STRUCTURAL 1/2" = 1'-0"5 SNOW GATE - EAST ELEVATION - STRUCTURAL 1 1 2 REV. DATE 1 BP4 ADDENDUM 1 10/21/2019 2 BP4 ADDENDUM 3 12/11/2019 PD P4 P5P4.4 PE P4.8 14'-11"12'-6"8'-7"6'-0"21'-2 1/2"4'-0"95'-1"P5.2 1'-9" 1" 1'-0"4"8"1'-10"3'-11"1"1'-8"2'-4"F99'-6"9'-6"10"1"11"9"2'-2"12'-9" 12 S-502 F995'-1"1'-0"2"1"1'-0" 9 S-503 F895'-1"S-503 5 7 S-503 S-503 6 2 S-503 1 S-503 2"1'-0"1'-0"2'-0"3" REF DET 3/S-503 8 S-503 4 1/2"10"1'-0"3 1/2"2'-0" THICK MAT FTG W/ #7 @ 12" OC T&B EA WAY TOF EL 95'-1". PROVIDE STD HOOKS ON ALL EAST/WEST REINF FTG PER 12/S-502 MAT FDN 10 S-503 1'-4 1/2" FDN DRAIN CONN TO STORM SEWER, REFER TO CIVIL FDN DRAIN, REFER TO CIVIL PD P4 P5P4.4 PE P4.8 14'-11"12'-6"8'-7"6'-0"21'-2 1/2"100'-1" P5.2 100'-1" 105'-9"20'-0"10"10"9'-2"10'-0"9 S-503 7 S-503 2 S-503 1 S-503 3'-8" RO 6'-4"2'-6"1"RO3'-4"1"10"2'-11 1/2" RO 6'-7"2'-11 1/2" 4 S-503 11 S-535 11 S-535 1'-11 1/2" RO 8'-11 1/2" 8 S-503 TO OPENING 108'-4" TOW 100'-8 1/2", TYP UNO HSS8X4X1/4 TO STL 102' - 6" PCC MFR SHALL COORD ROUGH OPENING SIZE W/ ELEVATOR SUPPLIER, REFER TO 17/S-535 FOR SILL DETAIL 4 1/2"10"12 S-502 10 S-503 PROVIDE RUBBED FINISH AT EXPOSED CIP WALL, TYP AT SOUTH TOWER PCC MFR SHALL COORD EMBEDS OR POST-INSTALLED CONNS FOR STAIR RAILING W/ RAILING SUPPLIER, RAILING NOT IN BP #4 1'-0"3" 3"7"3" 8" WIDE LEDGE, TYP 17 S-501 SP 13 S-551 13 S-551 11 S-503 11 S-503 MIN 1'-0"MIN 3'-0"MIN 1'-0"COORD WALL STRUCTURAL INFILL WITH ELEV INSTALL 5'-0"1'-1"5'-0"1"5'-10"8'-3"11"5'-0"SP PD P4 P5P4.4 PE P4.8 14'-11"12'-6"8'-7"6'-0"21'-2 1/2"111'-5" P5.2 SPAN OF 6" PCC SLAB 10"10"9'-2"10'-0"HSS8X6X1/2 TO STL 111'-3" 111'-5" 117'-1" 3'-8" RO 6'-4"2'-6"RO3'-4"10"11 S-535 11 S-535 1'-11 1/2" RO 8'-11 1/2" BOT OPG 112'-6" TO OPG 119'-8" 4" HSS8X4X1/4 TO STL 113' - 10"4 1/2"10"1'-0"3" 3"7"3" 8" WIDE LEDGE, TYP PROVIDE VERT EJ, PREFORMED EXPANDING FOAM W/ FACTORY APPLIED SILICONE SEALANT ± 50% MOVEMENT, EACH SIDE OF TOWER 13 S-551 13 S-551 1 S-522 SP 16 S-535 PCC MFR SHALL COORD ROUGH OPENING SIZE W/ ELEVATOR SUPPLIER, REFER TO 9/S-535 FOR SILL DETAIL PCC MFR SHALL COORD EMBEDS OR POST-INSTALLED CONNS FOR STAIR RAILING W/ RAILING SUPPLIER, RAILING NOT IN BP #4 MIN 1'-0"MIN 3'-0"MIN 1'-0"5'-0"1'-1"5'-0"1"8'-3"11"5'-0"SP PD P4 P5P4.4 PE P4.8 14'-11"12'-6"8'-7"6'-0"21'-2 1/2"122'-9" P5.2 SPAN OF 6" PCC SLAB HSS8X6X1/2 TO STL 122'-7"10"10"9'-2"10'-0"122'-9" 128'-5" 3'-8" RO 6'-4"2'-6" 11 S-535 11 S-535 1'-11 1/2" RO 8'-11 1/2" BOT OPG 123'-10" TO OPG 130'-2" 4"4 1/2"10"3"7"3" 8" WIDE LEDGE, TYP PROVIDE VERT EJ, PREFORMED EXPANDING FOAM W/ FACTORY APPLIED SILICONE SEALANT ± 50% MOVEMENT, EACH SIDE OF TOWER 1'-0"3" 13 S-551 13 S-551 1 S-522 HSS8X4X1/4 TO STL 125' - 2" SP 16 S-535 PCC MFR SHALL COORD ROUGH OPENING SIZE W/ ELEVATOR SUPPLIER, REFER TO 9/S-535 FOR SILL DETAIL PCC MFR SHALL COORD EMBEDS OR POST-INSTALLED CONNS FOR STAIR RAILING W/ RAILING SUPPLIER, RAILING NOT IN BP #4 MIN 1'-0"MIN 3'-0"MIN 1'-0"10"BO3'-4"5'-0"1'-1"5'-0"1"8'-3"11"5'-0"SP Architecture | Engineering | Interior Design 1715 Magnavox Way Fort Wayne, IN 46804 260.432.9337 930 North Meridian Indianapolis, IN 46204 317.917.1190 www.msktd.com SHEET TITLE SHEET NUMBER SET DESCRIPTION BP #4 - Garage / Bridge Structural Package PROJECT NO. DATE MSKTD & Associates 12/16/2019 12:54:39 PMENLARGED SOUTH TOWER PLANS - STRUCTURAL S-401 Carmel, IndianaFranciscan OrthopedicCenter of Excellence7382 10/11/2019NEW PARKING STRUCTURENORTH 1/4" = 1'-0"1 FOUNDATION PLAN - SOUTH TOWER - STRUCTURAL NORTH 1/4" = 1'-0"2 LEVEL 1 PLAN - SOUTH TOWER - STRUCTURAL NORTH 1/4" = 1'-0"3 LEVEL 2 PLAN - SOUTH TOWER - STRUCTURAL NORTH 1/4" = 1'-0"4 LEVEL 3 PLAN - SOUTH TOWER - STRUCTURAL 1 1 1 2 22 REV. DATE 1 BP4 ADDENDUM 1 10/21/2019 2 BP4 ADDENDUM 3 12/11/2019 PD P4 P5P4.4 PE P4.8 14'-11"12'-6"8'-7"6'-0"21'-2 1/2"134'-1" 4 S-431 P5.2 SPAN OF 6" PCC SLAB REFER TO S-431 FOR PEDESTRIAN BRIDGE PLANS HSS8X6X1/2 TO STL 133'-11"10"10"9'-2"10'-0"134'-1" 3'-8" RO 6'-4"2'-6" 11 S-535 11 S-535 1'-11 1/2" RO 8'-11 1/2" BOT OPG 134'-4" TO OPG 146'-10" 4" HSS8X4X1/4 TO STL 136' - 6"4 1/2"10"6 S-562 3"7"3" 8" WIDE LEDGE, TYP PROVIDE VERT EJ, PREFORMED EXPANDING FOAM W/ FACTORY APPLIED SILICONE SEALANT ± 50% MOVEMENT, EACH SIDE OF TOWER 1'-0"3" 1 S-522 SP 16 S-535 13 S-551 PCC MFR SHALL COORD ROUGH OPENING SIZE W/ ELEVATOR SUPPLIER, REFER TO 9/S-535 FOR SILL DETAIL PCC MFR SHALL COORD EMBEDS OR POST-INSTALLED CONNS FOR STAIR RAILING W/ RAILING SUPPLIER, RAILING NOT IN BP #4 MIN 1'-0"MIN 3'-0"MIN 1'-0"COORD WALL STRUCTURAL INFILL WITH ELEV INSTALL 10"RO3'-4"6'-1"5'-0" 1" SP PD P4 P5P4.4 PE P4.8 14'-11"12'-6"8'-7"6'-0"21'-2 1/2"4 S-431 P5.2 149'-0" REFER TO S-431 FOR PEDESTRIAN BRIDGE PLANS 10"10"19'-2"10"4 1/2"SPAN OF 6" PCC SLAB SPAN OF 6" PCC SLAB SPAN OF 6" PCC SLAB RD W8X48TO STL 147' - 10 1/2"TOW 150'-11 1/2", TYP 8 S-562 8" WIDE LEDGE, TYP 8" WIDE LEDGE, COORD MAX DEPTH W/ ELEV SUPPLIER 2 S-522 5 S-522 5 S-522 6 S-522 6 S-522 Architecture | Engineering | Interior Design 1715 Magnavox Way Fort Wayne, IN 46804 260.432.9337 930 North Meridian Indianapolis, IN 46204 317.917.1190 www.msktd.com SHEET TITLE SHEET NUMBER SET DESCRIPTION BP #4 - Garage / Bridge Structural Package PROJECT NO. DATE MSKTD & Associates 12/16/2019 12:54:41 PMENLARGED SOUTH TOWER PLANS - STRUCTURAL S-402 Carmel, IndianaFranciscan OrthopedicCenter of Excellence7382 10/11/2019NEW PARKING STRUCTURENORTH 1/4" = 1'-0"1 LEVEL 4 PLAN - SOUTH TOWER - STRUCTURAL NORTH 1/4" = 1'-0"2 ROOF PLAN - SOUTH TOWER - STUCTURAL 2 REV. DATE 1 BP4 ADDENDUM 1 10/21/2019 2 BP4 ADDENDUM 3 12/11/2019 PC PB P6 62'-0"1 S-502 3 S-502 TOF 94'-3" WJ WJ WJ WJ EQEQEQEQEQWJ FS TOF 96'-3" WALL CONTROL JOINT, TYP. REFER TO DET 12/S-501 17'-6" 1'-0"4'-6"7'-2"5'-4"8"7"7"35'-4"8"14'-4"8"9'-10"7"7"TOF 94'-3" 4 S-502 3 S-502 TYP WJ WJ WJ WJ WJ TOF 96'-3"TOF 94'-3" WJ FS 17'-6" 4 S-502 WJ WJ WJ WJ WJWJ WJ PC PB P6 62'-0"6"35'-5"8"14'-4"8"10'-5"1'-0"11'-8"5'-4"8" 1 S-502 3 S-502 TD15'-0 1/2"RO6'-4"24'-7 1/2"RO3'-4"3'-8"RO3'-4"5'-8"96'-6" TYP TO FF EL TYP 7 S-501 SIM TRENCH DRAIN, REFER TO MECH/ PLUMBING DRAWINGS 3 S-502 PD P2 11 S-521 7'-0"7'-0"7'-0"7'-0"4'-1"2'-11" TAPERED HSS 20X8X5/16, TYP OF 6 HSS10X5X1/4 PD P7 11 S-521 4'-1"7'-0"7'-0"7'-0"7'-0"7'-0" TAPERED HSS 20X8X5/16, TYP OF 6 HSS10X5X1/4 Architecture | Engineering | Interior Design 1715 Magnavox Way Fort Wayne, IN 46804 260.432.9337 930 North Meridian Indianapolis, IN 46204 317.917.1190 www.msktd.com SHEET TITLE SHEET NUMBER SET DESCRIPTION BP #4 - Garage / Bridge Structural Package PROJECT NO. DATE MSKTD & Associates 12/16/2019 12:54:42 PMENLARGED PLANS - STRUCTURAL S-421 Carmel, IndianaFranciscan OrthopedicCenter of Excellence7382 10/11/2019NEW PARKING STRUCTURENORTH 1/4" = 1'-0"1 FOUNDATION PLAN - ROOMS BENEATH RAMP - STRUCTURAL NORTH 1/4" = 1'-0"2 LEVEL 1 PLAN - ROOMS BENEATH RAMP - STRUCTURAL TOW EL 99'-6" TYP NORTH 1/4" = 1'-0"3 LEVEL 2 PLAN - WEST CANOPY - STRUCTURAL NORTH 1/4" = 1'-0"4 LEVEL 2 PLAN - EAST CANOPY - STRUCTURAL 11 REV. DATE 1 BP4 ADDENDUM 3 12/11/2019 PCC WALL PANEL PCC TEE WATSON-BOWMAN ME-400 EJ OR APPROVED EQUAL, PROVIDE WALL TO SLAB CONDITION BEYOND DOORWAY SLIDE BEARING 5"5" PCC BRACKET REFER TO PLAN CIP TOPPING REINF, REFER TO PLANCONC DAM TOOLED JOINT W/ SEALANT PCC SLAB 3" REFER TO PLAN 1"10" CURTAINWALL, REFER TO ARCH4'-1 1/2"REFER TO PLANS TOW EL REFER TO PLANS TOS EL PCC WALL (BEYOND) CONN BY PCC MFR ROOFING, REFER TO ARCH 6" PCC SLAB BEARING PAD PCC LEDGE PCC BEAM PCC BRACKET (BEYOND) CIP TOPPING SEALANT, REFER TO DET 3/S-541, SIM P7.8 DIAPH REINF, REFER TO PLAN REFER TO PLANS CIP WASH CONC DAM PCC WALL PANEL REFER TO PLAN TOS EL 2"10" HORIZONTAL SLOTTED CONN BY PCC MFR 3"PCC TEE PCC WALL PANEL PCC TEE SEALANT, REFER TO DET 3/S-541, SIM BEARING PAD 5"5" REFER TO PLANS CIP WASH PCC BRACKET REFER TO PLAN HORIZ SLOTTED CONN BY PCC MFR CIP TOPPING REINF, REFER TO PLAN3"CONC DAM PCC LEDGE REFER TO PLAN PCC STAIR SLAB CONN BY PCC MFR REFER TO PLAN TOS EL BACKER ROD & SEALANT PCC WALL PCC SLAB BEARING PAD ROOFING, REFER TO ARCH REFER TO PLAN TO STL EL STEEL HOIST BEAM EMBED BY PCC MFR, SHEAR CONN BY STEEL FABRICATOR REFER TO PLAN TOS EL PCC WALL PCC SLAB ROOFING, REFER TO ARCH REFER TO PLAN TOW EL CIP TOPPING P7.8 DIAPH REINF, REFER TO PLAN REFER TO PLANS CIP WASH CONC DAM PCC WALL PANEL REFER TO PLAN TOS EL 2"10" PCC STAIR SLAB REFER TO PLAN TOOLED JOINT W/ SEALANT PCC TEE Architecture | Engineering | Interior Design 1715 Magnavox Way Fort Wayne, IN 46804 260.432.9337 930 North Meridian Indianapolis, IN 46204 317.917.1190 www.msktd.com SHEET TITLE SHEET NUMBER SET DESCRIPTION BP #4 - Garage / Bridge Structural Package PROJECT NO. DATE MSKTD & Associates 12/16/2019 12:54:44 PMPCC FRAMING DETAILS - STRUCTURAL S-522 Carmel, IndianaFranciscan OrthopedicCenter of Excellence7382 10/11/2019NEW PARKING STRUCTURE3/4" = 1'-0"1 PCC TEE TO PCC WALL DETAIL 3/4" = 1'-0"2 PCC SLAB/ BEAM DETAIL 3/4" = 1'-0"3 PCC TEE TO PCC WALL DETAIL 3/4" = 1'-0"4 PCC TEE TO PCC WALL DETAIL 3/4" = 1'-0"5 PCC DETAIL 3/4" = 1'-0"6 PCC DETAIL 3/4" = 1'-0"7 PCC TEE TO PCC WALL DETAIL 1 REV. DATE 1 BP4 ADDENDUM 3 12/11/2019