Loading...
HomeMy WebLinkAboutasi-09_with attachments-BP#4.1 revisionsARCHITECT'S SUPPLEMENTAL INSTRUCTIONS PROJECT: Franciscan Orthopedic Center of Excellence ARCHITECT'S SUPPLEMENTAL BP #4.1 INSTRUCTION NO.: ASI-09 OWNER: Tonn & Blank Construction, LLC DATE OF ISSUANCE: January 29, 2020 TO: Tonn & Blank Construction, LLC.ARCHITECT:MSKTD & Associates, Inc. 5721 Progress Road 930 North Meridian Street Indianapolis, IN 46241 Indianapolis, IN 46204 ARCHITECT'S PROJECT NO.: 7382 The Work shall be carried out in accordance with the following Supplemental Instructions issued in accordance with the Contract Documents without change in Contract Sum or Contract Time. Prior to proceeding in accordance with these instructions, indicate your acceptance of these instructions for minor change to the Work as consistent with the Contract Documents and return a copy to the Architect. Description: ASI-9.1 See attached ASI #9 from IMEG regarding BP #4.1 revisions. Attachments: ASI #9 Narrative and Drawings from IMEG cc:Joel Booker (joel.booker@tonnandblank.com) Wes Robledo (Wesley.robledo@tonnandblank.com) JD Taylor (jdtaylor@cesolutionsinc.com) Doug Gannon (Doug.Gannon@wginc.com) Daryl Humble (daryl.r.humble@imegcorp.com) Susan Smith (Susan.K.Smith@imegcorp.com) Sherri Wilson (swilson@cripe.biz) Jaclyn Hensel (jhensel@cripe.biz) Jennifer Lasch (jlasch@cripe.biz) Karisa Laughlin (karisa@fourpointdp.com) Alyssa Prazeau (aprazeau@context-design.com) DNS/RJH/DGG/JPC/AKL/File ISSUED: MSKTD & Associates, Inc.ACCEPTED: BY:Bob Harmeyer BY: Architect/Engineer Contractor Date Franciscan Health Orthopedic Center of Excellence IMEG #18004130.00 ASI #08 Page 1 of 1 PLUMBING/MECHANICAL/ELECTRICAL BP #4.1 ASI #9 PLUMBING: DRAWING ITEMS 1.P0-00 – PLUMBING COVERSHEET a.DELETE drawing in its entirety and replace with revised drawing attached. See clouded area(s) on drawing for changes. ELECTRICAL: DRAWING ITEMS 2.E1-00 – ELECTRICAL SITE PLAN a.DELETE drawing in its entirety and replace with revised drawing attached. See clouded area(s) on drawing for changes. TECHNOLOGY: DRAWING ITEMS 1.T1-00 – TECHNOLOGY SITE PLAN a.DELETE drawing in its entirety and replace with revised drawing attached. See clouded area(s) on drawing for changes. END OF PLUMBING/MECHANICAL/ELECTRICAL BP#4.1 ASI #09 Enclosures PLUMBING SYMBOL LISTSYMBOL:DESCRIPTION:PIPE SERVING FIXTURE ON FLOOR ABOVE(EXAMPLE: FD = FLOOR DRAIN)FDPITCH PIPE IN DIRECTIONRD-16"(1000)ROOF DRAIN PROPERTIESSYMBOLSIZE (ROOF SQ. FT.)DIELECTRIC CONNECTIONUNION/FLANGEBALANCING VALVE (NUMBER INDICATES GPM)GPMCHECK VALVEREDUCER -REFERENCE SPECIFICATIONFOR CONCENTRIC/ECCENTRIC AND FOT/FOBMETERMALIGNMENT GUIDEPIPE ANCHOREXPANSION JOINTPIPE CAPPIPE DOWNPIPE UP OR UP/DOWNDIRECTION OF FLOW IN PIPENEW CONNECTIONSHUTOFF VALVE NORMALLY OPENSHUTOFF VALVE NORMALLY CLOSEDACID VENTAVACID WASTEAWCOLD WATER -POTABLECWDTDRAIN TILESANITARY DRAINAGE (GREASE SANITARY DRAINAGE)GSANHOT WATER -POTABLEHWHOT WATER CIRCULATING -POTABLEHWCHOT WATER -POTABLE. NUMBER INDICATES TEMPHW140HOT WATER CIRC. -POTABLE. NUMBER INDICATES TEMPHWC140NON-POTABLE COLD WATERNCWNON-POTABLE HOT WATERNHWPUMPED DISCHARGEPDSANITARY DRAINAGESANSOFT COLD WATERSCWSOFT HOT WATERSHWSTORM DRAINAGE (ROOF SQUARE FOOTAGE)ST(1,000)STSSTORM DRAINAGE (SECONDARY)VENTVWASTE ANETHESIA GAS DISPOSALWAGDGREASE VENTGVCOMPRESSED AIRCADEIONIZED WATERDIPROPANE GASPREVERSE OSMOSIS WATERROSTWSOFT TEMPERED WATERTWTEMPERED WATERDRAINDGNATURAL GASNOT ALL SYMBOLS MAY APPLY.PRESSURE REDUCING VALVE (LIQUID/GAS)OIL RETURNOROIL SUPPLYOSLAB VACUUMVACSOLENOID VALVESAFETY/RELIEF VALVEVACUUM BREAKERPRESSURE GAUGE (FURNISHED WITH BALL VALVE)PTEMPERATURE SENSOR WITH WELLTTHERMOMETER WITH WELL (DIAL TYPE)TTHERMOMETER WITH WELL (FILLED TYPE)PUMPGRVGAS REGULATOR VENTINSTRUMENT AIRIAMEDICAL AIRMAMEDICAL VACUUMMVNITROGENNNITROUS OXIDENOOXYGENOPURE WATERPWSERVICE WATER -POTABLEWPIPE CONTINUATIONPRESSURE SENSOR (FURNISHED WITH BALL VALVE)PROUTE TO DRAINPLUMBING ABBREVIATION KEYBATHTUBBTCOCLEANOUTCLINICAL SINKCSDRINKING FOUNTAINDFEMERGENCY EYEWASHEEFLOOR CLEANOUTFCOFLOOR DRAINFDFLOOR SINKFSGARBAGE DISPOSERGDGREASE INTERCEPTORGIHOSE BIBBHBI.E.INVERT ELEVATION (FOR REFERENCE ONLY)LAVATORYLAVMOP BASINMBMHMANHOLEMIXING VALVEMVNEUTRALIZATION TANKNTOIL SEPARATOROSROOF DRAINRDSHOWERSHSINKSKSERVICE SINKSSTRENCH DRAINTDTRAP PRIMERTPURINALURWATER CLOSETWCWALL CLEANOUTWCOWASH FOUNTAINWFWATER HEATERWHWASHING MACHINE FIXTUREWMFYARD CLEANOUTYCOEMERGENCY SHOWERESEMERGENCY SHOWER/EYEWASHESEELECTRIC WATER COOLEREWCVENT THROUGH ROOFVTRADACCESS DOORABOVE FINISHED FLOORAFFBFPBACKFLOW PREVENTERNCNEW CONNECTIONNOT IN CONTRACTNICABBR: DESCRIPTION:TYPICALTYPUNLESS NOTED OTHERWISEUNOEXISTINGEFLOW METERFMWATER SOFTENERWSWATER METERWMDIALYSIS BOXDBCATCH BASINCBCAST IRONCIDUCTILE IRONDIUTILITY BOXUBPLAN OR DETAIL NUMBERPLAN OR DETAIL NAMEPLAN OR DETAIL SCALEDETAIL REFERRED TO BY SECTION CUTSHEET DETAIL IS LOCATED ONNAME1VIEW NAME1/8" = 1'-0"1M1011432T101SIMDETAIL REFERRED TO BY ELEVATIONSHEET DETAIL IS LOCATED ONINDICATES SIMILAR DETAIL REFERENCED IN MULTIPLE LOCATIONSSIMINDICATES SIMILAR DETAIL REFERENCED IN MULTIPLE LOCATIONSLEVEL NAME10' - 0"HEIGHT ABOVE PROJECT 0' -0" 1INDICATES NOTE USED TO DESCRIBE ADDITIONAL INFORMATION ABOUT WORK REQUIRED, SPECIFIC TO THE SHEET AND/OR DETAIL NORHTINDICATES DIRECTION OF TRUE NORTHVIEW KEYNEW WORK BY THIS CONTRACTOR (DARK SOLID LINE)NEW WORK UNDERFLOOR OR UNDERGROUND BY THIS CONTRACTOR (DARK LONG DASHED LINE)NEW WORK BY OTHERS AND/OR EXISTING TO REMAIN (LIGHT SOLID LINE)EXISTING TO BE REMOVED BY THIS CONTRACTOR(DARK SHORT DASHED LINE)LINE TYPE KEY:BUILDING CODE: INDIANA BUILDING CODE WITH AMENDMENTS 2014 EDITIONFIRE CODE: INDIANA FIRE CODE WITH AMENDMENTS2012 EDITIONLIFE SAFETY CODE: NFPA 101 2012 EDITION WITH AMENDMENTSMECHANICAL CODE: INDIANA MECHANICAL CODE WITH AMENDMENTS2014 EDITIONELECTRICAL CODE: IEC 2009 EDITION WITH AMENDMENTS(NFPA 70-2008) PLUMBING CODE: INDIANA PLUMBING CODE WITH AMENDMENTS2012 EDITIONFIRE CODE: INDIANA FIRE CODE WITH AMENDMENTS2014 EDITIONACCESSIBILITY CODE: INDIANA BUILDING CODE CHAPTER-11WITH AMENDMENTS2014 EDITIONELEVATOR CODE: ASME 17.3-2005, ASME QEI-1-2007 WITH AMENDMENTSANSI/ASCE/T & D1 21-08ENERGY CODE: INDIANA ENERGY CONSERVATION WITH AMENDMENTSCODE 2010OTHER APPLICABLE CODE: FGI GUIDELINES FOR DESIGN AND CONSTRUCTION OF HOSPITALS AND HEALTHCARE FACILITIES 2018 EDITIONAPPLICABLE CODESCONTRACTOR SHALL COMPLY WITH APPLICABLE CODES AND LOCAL AMENDMENTS.TEMPERATURE CONTROLS CONTRACTORT.C.C.SECURITY CONTRACTORS.C.AUDIO/VISUAL CONTRACTORA.V.C.NURSE CALL CONTRACTORN.C.C.CIVIL CONTRACTORC.C.FIRE PROTECTION CONTRACTORF.P.C.HEATING CONTRACTORH.C.PLUMBING CONTRACTORP.C.GENERAL CONTRACTORG.C.MECHANICAL CONTRACTORM.C.VENTILATION CONTRACTORV.C.ELECTRICAL CONTRACTORE.C.CONTRACTOR ABBREVIATION KEYABBR: DESCRIPTION:TECHNOLOGY CONTRACTORT.C.CONSTRUCTION MANAGERC.M.FOOD SERVICE CONTRACTORF.S.C.MECHANICAL GENERAL NOTES:THESE NOTES APPLY TO ALL MECHANICAL SHEETS AND TRADES, INCLUDING BUT NOT LIMITED TO, FIRE PROTECTION, PLUMBING, MEDICAL GAS, VENTILATION, PIPING AND TEMPERATURE CONTROL.1. DRAWINGS SHOWING LOCATIONS OF EQUIPMENT, DUCTWORK, PIPING, ETC. ARE DIAGRAMMATIC AND MAY NOT ALWAYS REFLECT EXACT INSTALLATION CONDITIONS. DRAWINGS SHOW THE GENERAL ARRANGEMENT OF DUCTWORK, PIPING, EQUIPMENT, ETC., AND MAY NOT INCLUDE ALL OFFSETS AND FITTINGS REQUIRED FOR COMPLETE INSTALLATION. THE DRAWINGS SHALL BE FOLLOWED AS CLOSELY AS ACTUAL BUILDING CONSTRUCTION AND THE WORK OF OTHERS WILL PERMIT.2. DO NOT SCALE DRAWINGS. VERIFY ALL DIMENSIONS AND CLEARANCES FROM ARCHITECTURAL, STRUCTURAL, SUBMITTALS, AND OTHER APPROPRIATE DRAWINGS OR PHYSICALLY AT SITE. REVIEW ALL DRAWINGS, INCLUDING THOSE OF OTHER TRADES.3. COORDINATE ALL WORK WITH ALL OTHER TRADES PRIOR TO INSTALLATION TO PROVIDE CLEARANCES REQUIRED FOR OPERATION, MAINTENANCE, CODE COMPLIANCE, AND TO VERIFY NON-INTERFERENCE WITH OTHER WORK. DO NOT FABRICATE PRIOR TO VERIFICATION OF NECESSARY CLEARANCES FOR ALL TRADES. BRING ANY INTERFERENCES OR CONFLICTS TO THE ATTENTION OF THE ARCHITECT/ENGINEER BEFORE PROCEEDING WITH FABRICATION OR EQUIPMENT ORDERS.4. REVIEW SPACE REQUIREMENTS OF EQUIPMENT SPECIFIED OR SUBSTITUTED AND MAKE REASONABLE ACCOMMODATIONS IN LAYOUT AND POSITIONING TO PROVIDE PROPER ACCESS.5. ANY CHANGES REQUIRED TO ELIMINATE CONFLICTS OR THAT RESULT FROM A FAILURE TO COORDINATE SHALL BE MADE BY THE CONTRACTOR WITHOUT ADDITIONAL COST OR EXPENSE TO OTHERS.6. EACH CONTRACTOR IS RESPONSIBLE FOR ALL COSTS ASSOCIATED WITH ELECTRICAL CHANGES REQUIRED FOR EQUIPMENT PROPOSED THAT DIFFERS FROM THE BASIS OF DESIGN.7. REFER TO ARCHITECTURAL REFLECTED CEILING PLAN, ELECTRICAL, TECHNOLOGY AUDIO/VISUAL, AND OTHER MECHANICAL PLANS FOR EXACT LOCATIONS OF ALL CEILING MOUNTED DEVICES, OTHER THAN SPRINKLERS. 8. EACH CONTRACTOR IS RESPONSIBLE FOR DAMAGE CAUSED BY THEIR ACTIONS TO WALLS, FLOORS, CEILINGS, AND ROOFS. THE CONTRACTOR WHOSE WORK CAUSES DAMAGE IS RESPONSIBLE FOR PATCHING TO MATCH ORIGINAL CONSTRUCTION, FIRE RATING, AND FINISH.9. IN AREAS WITH DRYWALL CEILINGS COORDINATE LOCATIONS OF ACCESS PANELS WITH THE GC FOR ACCESS TO VALVES, DUCTWORK ACCESSORIES, DAMPERS, ETC. COORDINATE PANEL TYPE AND COLOR WITH ARCHITECT. NOTIFY THE GC OF THE REQUIRED ACCESS PANELS PRIOR TO BIDDING.10. SEAL ALL FLOOR, WALL, AND ROOF PENETRATIONS AIRTIGHT WHERE CONDUITS, PIPING, AND DUCTS PENETRATE. PENETRATIONS THROUGH EXTERIOR WALLS AND ROOF SHALL BE SEALED AIRTIGHT WITH WATERPROOFING MATERIALS RECOMMENDED BY MANUFACTURER FOR OUTDOOR USE.11. CAULK ALL PIPE AND DUCT PENETRATIONS OF FULL HEIGHT NON-FIRE RATED WALL, PARTITION, FLOOR, AND ROOF ASSEMBLIES. THIS IS ESSENTIAL TO PREVENT NOISE TRANSMISSION FROM ONE ROOM TO ANOTHER AND TO PROVIDE THE DESIRED NC LEVELS WITHIN ROOMS.12. WHERE PIPES AND DUCTS ARE SHOWN TO PENETRATE FLOORS, PROVIDE SLEEVED OPENINGS WITH THE TOP EDGE RAISED ABOVE FLOOR SURFACE IN ACCORDANCE WITH ALL RELEVANT SPEC SECTIONS. SEAL SLEEVE PERIMETER TO BE WATERTIGHT.13. EQUIPMENT SIZES AND SERVICE CLEARANCE REQUIREMENTS VARY AMONG DIFFERENT MANUFACTURERS. CONSULT APPROVED SHOP DRAWINGS FOR EQUIPMENT SIZES AND REQUIRED SERVICE CLEARANCES. COORDINATE WITH LAYOUT OF EQUIPMENT PADS, PIPING, DUCTWORK, ETC.14. DO NOT BLOCK TUBE PULL OR EQUIPMENT SERVICE CLEARANCES. 15. MAINTAIN MINIMUM 3'-6” CLEARANCE IN FRONT OF ALL ELECTRICAL PANELS, MOTOR STARTERS, SWITCHES, AND DISCONNECTS.16. PROVIDE CONCRETE EQUIPMENT PAD FOR ALL FLOOR MOUNTED EQUIPMENT. PAD SHALL EXTEND MINIMUM 6” BEYOND ALL SIDES OF EQUIPMENT.17. DO NOT SUPPORT EQUIPMENT, PIPING, OR DUCTWORK FROM METAL DECKING OR OTHER NON-STRUCTURAL BUILDING ELEMENTS. ANCHORS EMBEDDED IN CONCRETE SHALL BE CRACKED CONCRETE APPROVED IN ACCORDANCE WITH SPECIFICATIONS.1. THE SYMBOLS AND THE MATERIAL LIST ARE FOR THE CONVENIENCE OF THE CONTRACTOR. CONTRACTOR SHALL VERIFY QUANTITIES AND FURNISH ALL MATERIALS REQUIRED FOR FULLY OPERATIONAL SYSTEMS, WHETHER SPECIFIED OR NOT.2. CATALOG NUMBERS SHALL NOT BE CONSIDERED COMPLETE, BUT ARE GIVEN AS AN AID TO THE CONTRACTOR AND TO INDICATE THE QUALITY REQUIRED. CONTRACTOR IS RESPONSIBLE FOR A COMPLETE DESCRIPTION OF MATERIAL ON THESE DRAWINGS AND IN THE SPECIFICATIONS BEFORE ORDERING. THE DESCRIPTION OF THE MATERIAL TAKES PRECEDENCE OVER THE CATALOG NUMBER. THE FIRST MANUFACTURER LISTED IS THE BASIS OF DESIGN.3. CONTRACTOR SHALL VERIFY THAT FIXTURES SUPPLIED ARE APPROVED PER ALL APPLICABLE STATE, LOCAL AND GOVERNING AUTHORITIES.4. ALL FIXTURES SHALL CONFORM TO FEDERAL ACT S.38745. INVERT ELEVATIONS ARE FROM ENGINEERING DRAWINGS AND MAY NOT BE ACCURATE. VERIFY ALL ELEVATIONS BEFORE BEGINNING WORK.6. VERIFY UNDERGROUND PIPE SIZES, INVERT ELEVATIONS, AND LOCATIONS PRIOR TO BEGINNING ANY WORK.7. REFER TO THE PLUMBING ROUGH-IN SCHEDULE FOR THE SIZES OF BRANCH PIPES TO PLUMBING FIXTURES.8. FOR CLARITY, NOT ALL VALVES HAVE BEEN SHOWN. PROVIDE SHUTOFF VALVES IN DOMESTIC WATER PIPING SERVING EACH ROOM WITH FIXTURES. ANGLE STOPS SHALL NOT BE CONSIDERED SHUTOFF VALVES. 9. PLUMBING CONTRACTOR SHALL CUT AND PATCH EXISTING AS REQUIRED FOR NEW OR DEMOLITION WORK UNLESS NOTED OTHERWISE. REFER TO SPECIFICATION SECTION 22 05 05 FOR ADDITIONAL INFORMATION.PLUMBING GENERAL NOTES:GRADEBLACKTOP OR CLEAN TAMPED EARTH.ALL AROUNDMINIMUM 9"FLEXIBLE PVC COUPLING WITH STAINLESS STEEL BAND CLAMPS. SUITABLE FOR UNDERGROUND INSTALLATION. INDIANA SEAL, MODEL NO. 156-88 OR EQUIVALENT.NEOPRENE GASKETLINE OF UNDISTURBED EARTH.8" SAN PIPE. SEE SPECIFICATION SECTION 22 10 00 FOR MATERIAL.1/8 BEND.CLEANOUT ASSEMBLY. SEE PLUMBING MATERIAL LIST.CONCRETE SLAB (5") REINFORCED WITH WIRE MESH OR 3/8" DIAMETER RODS 6" CENTERS EACH WAY. SLOPE AWAY FROM CLEANOUT ASSEMBLY TOP.EXTEND CONCRETE PAD 6" BEYOND THE LINE OF UNDISTURBED EARTH.SAND BACKFILL OR CLEAN TAMPED EARTH.FROST SLEEVEPREDICTED DEPTH OF FROST..FROST SLEEVE TO BE 6" BELOW PREDICTED DEPTH OF FROST,.6" TO 12" ABOVE SEWER-OR-CLAMPING RINGWATER CUTOFF MASTICADJUSTABLE EXTENSIONROOF DECKROOF INSULATIONDOME STRAINERBEARING PANUNDERDECK CLAMPOUTLET SIZE AS SHOWN ON DRAWINGSPRIMARY ROOF DRAINSECONDARY ROOF DRAININTERNAL WATER DAMROOF MEMBRANENOTE: THIS DETAIL APPLIES TO RD-1 AND RD-2 ONLY..KYLEDWILSP R O FESSIONALENGINEERONNo.PE11200655ANAIDNIDERETSIGER STATE OFArchitecture | Engineering | Interior Design1715 Magnavox WayFort Wayne, IN 46804260.432.9337930 North MeridianIndianapolis, IN 46204317.917.1190www.msktd.comSHEET TITLESHEET NUMBERSET DESCRIPTIONBP #4.1 - Parking Garage &Skybridge Arch / MEPT /Interiors PackagePROJECT NO. DATEMSKTD& Associates12/12/191/29/2020 2:07:38 PMPLUMBINGCOVERSHEETP0-0010776 and 10777 Illinois StreetCarmel, IndianaFranciscan OrthopedicCenter of Excellence18004130.0001-23-20A Project for:8900 KEYSTONE XING SUITE 210INDIANAPOLIS, IN 46240317.848.5045 FAX: 317.844.2201www.imegcorp.comPLUMBING SHEET INDEXP0-00 PLUMBING COVERSHEETP3-0G FOUNDATION PLAN - PLUMBINGP3-1G FIRST FLOOR PLAN - PLUMBINGP3-2G SECOND FLOOR PLAN - PLUMBINGP3-3G THIRD FLOOR PLAN - PLUMBINGP3-4G FOURTH FLOOR PLAN - PLUMBINGP3-4S SKYBRIDGE FLOOR AND ROOF PLANS - PLUMBINGP3-5G ROOF PLAN - PLUMBINGPLUMBING FIXTURE SCHEDULETAG NAMEDESCRIPTIONMANF. & MODELFCO-1G HEAVY-DUTY FLOOR CLEANOUT - ROUND DURA-COATED CAST IRON CLEANOUT AND DOUBLE-FLANGED HOUSING, HEAVY-DUTY SECUREDSCORIATED DURA-COATED CAST IRON COVER WITH LIFTING DEVICE. BRONZE CLEANOUT PLUB AND GAS/WATERTIGHT SEAL.SMITH (4261), ZURN, JOSAM, WADE,WATTSFD-1G FLOOR DRAIN - 15" ROUND HEAVY DUTY PARKING DECK DRAIN, BOTTOM OUTLET, DURA-COATED CAST IRON BODY, HEAVY-DUTY GASKETED DRAINSUPPORT FLANGE, HEAVY-DUTY SLOTTED GRATE.ZURN (Z-536), WADE, JOSAM, WATTSRD-1G FLOOR DRAIN - 15" ROUND HEAVY DUTY PARKING DECK DRAIN, BOTTOM OUTLET, DURA-COATED CAST IRON BODY, HEAVY-DUTY GASKETED DRAINSUPPORT FLANGE, HEAVY-DUTY SLOTTED GRATE.ZURN (Z-536), WADE, JOSAM, WATTSTD-1G TRENCH DRAIN - MODULAR, PRE-SLOPED, POLYESTER FIBERGLASS CHANNEL, 8" WIDE, HEAVY DUTY CAST IRON GRATE, INTERLOCKING ENDS,HEAVY DUTY STEEL FRAME AND ANCHORING DEVICE, CATCH BASIN WITH 4" SIDE OUTLET AND SEDIMENT BUCKET, LENGTH AS SHOWN ONDRAWINGS.ZURN (Z806/812), WADE, JOSAM, WATTSYCO-1G YARD CLEANOUT - ROUND, DURA-COATED CAST IRON, SIZE AS LISTED ON DRAWINGS, DOUBLE FLANGED HOUSING, HEAVY DUTY SECUREDSCORIATED DURA-COATED CAST IRON COVER, LIFTING DEVICE, BRONZE CLEANOUT PLUG WITH GAS/WATER-TIGHT SEAL.ZURN (Z1474), WADE (8401), JOSAM(58680), WATTS (CO-300-MF)RD-1 ROOF DRAIN - CAST IRON BODY, SECURED CAST IRON DOME, 15" ROUND, BOTTOM OUTLET, FLASHING CLAMP, GRAVEL STOP, UNDERDECK CLAMP,BEARING PAN, ADJUSTABLE EXTENSION TO MATCH INSULATION THICKNESS, OUTLET SIZE AS LISTED ON DRAWINGS.ZURN (Z-100), WADE (3000), JOSAM(21500), WATTS (RD-300)RD-2 ROOF DRAIN - CAST IRON BODY, SECURED CAST IRON DOME, 15" ROUND, BOTTOM OUTLET, FLASHING CLAMP, GRAVEL STOP, UNDERDECK CLAMP,BEARING PAN, ADJUSTABLE EXTENSION TO MATCH INSULATION THICKNESS, INTERNAL STANDPIPE, OUTLET SIZE AS LISTED ON DRAWINGS.ZURN (Z-100), WADE (3000), JOSAM(21500), WATTS (RD-300)NO SCALE1 YARD CLEANOUT DETAILNO SCALE2 ROOF DRAIN DETAILREV. DATE1 ASI #9 - BP4.1 1/29/20201 observation area 40 yard rout e 140 yar d r out e 2O 2 G E N S E T F U E L T A N K G E N S E TTRASH C O M P A C T O R T R A S H C O M P A C T O R RECYCLE DUMPSTER ALTERNATE #EA-2 BATTING CAGE A L T E R N A T E #S A -2 S Y N T H E T IC T U R F A L T E R N A T E #S A -2 B A S K E T B A L L -H A L F C O U R T T E N N I S ALTERNATE #SA-3 FITNESS TRAIL/PATH ALTERNATE #SA-3 FITNESS TRAIL/PATH ALTERNATE #SA-3 FITNESS TRAIL/PATH E E E E E H 1.6 17 PB PA.3PA.2 PC PD PE P8P7.8 P7.1P7 P6 P5.2P5P4.8P4.4P4 P3 P2 P1.2P1 PA S4 GH-15 1 9 2 2 2 GAS EASEMENT GAS EASEMENT GAS EASEMENT GAS EASEMENT GAS EASEMENT GL-6 MONUMENT SIGN 3 4 5 GL-17 ECS 6 GL-17 ECS 6 GL-22 ECS 6 GL-22 ECS 6 S4 GH-15 S4 GH-15 S4 GH-15 S4 GH-15 S4 GH-15 1 8 8 7 7 1 1 1 1 MB PROFESSIONA L E NGINEERHUYLR.DAR L ENo. PE11300248 ANAIDN I DER ETSIGE RSTATE OF Architecture | Engineering | Interior Design 1715 Magnavox Way Fort Wayne, IN 46804 260.432.9337 930 North Meridian Indianapolis, IN 46204 317.917.1190 www.msktd.com SHEET TITLE SHEET NUMBER SET DESCRIPTION BP #4.1 - Parking Garage & Skybridge Arch / MEPT / Interiors Package PROJECT NO.DATE MSKTD & Associates 12/12/19 1/29/2020 10:27:28 AMELECTRICAL SITE PLAN E1-00 10776 and 10777 Illinois StreetCarmel, IndianaFranciscan OrthopedicCenter of Excellence18004130.00 01-23-20A Project for:8900 KEYSTONE XING SUITE 210 INDIANAPOLIS, IN 46240 317.848.5045 FAX: 317.844.2201 www.imegcorp.com N O R HT 1" = 40'-0"1 ELECTRICAL SITE PLAN - GARAGE GENERAL SHEET NOTES : 1. REFER TO SHEET E0-00 FOR ELECTRICAL SYMBOLS, ABBREVIATIONS, AND INSTALLATION NOTES. KEYNOTES: 1. PARKING GARAGE UTILITY TRANSFORMER. 2. NOT IN CONTRACT:(2) 4" CONDUITS IN CONCRETE ENCASED DUCT BANK FOR ROUTING OF ALL ELECTRICAL THROUGH GAS EASEMENT. DUCT BANK WILL CROSS AT 90 DEGREE ANGLE AND WILL BE ROUTED BELOW PIPING A MINIMUM OF 2' FROM THE BOTTOM OF PIPE. INSTALLATION OF ELECTRICAL OUTSIDE OF DUCTBANKS WITHIN EASEMENT SHALL NOT BE PERMITTED. REFER TO SITE UTILITY PLANS FOR ADDITIONAL INFORMATION. 3. PANEL GNH1A. 4. PANEL GLSH1A. 5. LIGHTING CONTACTOR LC-1. 6. REFER TO T1-00 FOR EMERGENCY CALL STATION LOCATION AND ADDITIONAL INFORMATION. 7. ALTERNATE SA-3:PROVIDE AN ALTERNATE COST FOR THE INSTALLATION OF ECS ELECTRICAL CONNECTION. 8. ALTERNATE SA-4:PROVIDE AN ALTERNATE COST FOR THE INSTALLATION OF ECS ELECTRICAL CONNECTION. 9. SURFACE MOUNT S4 TO THE UNDERSIDE OF SKYBRIDGE. # REV. DATE 1 ASI #9 - BP4.1 1/29/2020 1 observation area 40 yar d r out e 140 yar d r out e 2O 2 G E N S E T G E N S E TTRASH C O M P A C T O R T R A S H C O M P A C T O R RECYCLE DUMPSTER ALTERNATE #EA-2 BATTING CAGE A L T E R N A T E #S A -2 S Y N T H E T I C T U R F A L T E R N A T E #S A -2 B A S K E T B A L L -H A L F C O U R T T E N N IS ALTERNATE #SA-3 FITNESS TRAIL/PATH ALTERNATE #SA-3 FITNESS TRAIL/PATH ALTERNATE #SA-3 FITNESS TRAIL/PATH H 1.6 17 PB PA.3PA.2 PC PD PE P8P7.8 P7.1P7 P6 P5.2P5P4.8P4.4P4 P3 P2 P1.2P1 PA GAS EASEMENT GAS EASEMENT GAS EASEMENT GAS EASEMENT GAS EASEMENT ECS ECS ECS ECS 1 2 2 PW-HH-2 PW-HH-2 PW-HH-2 PW-HH-2 PW-HH-2 3 3 3 3 PW-HH-2 PW-HH-2 CONDUIT TO TR-1G 2 4 1 5 7 6 6 1 1 MB PROFESSIONA L E NGINEERHUYLR.DAR L ENo. PE11300248 ANAIDN I DER ETSIGE RSTATE OF Architecture | Engineering | Interior Design 1715 Magnavox Way Fort Wayne, IN 46804 260.432.9337 930 North Meridian Indianapolis, IN 46204 317.917.1190 www.msktd.com SHEET TITLE SHEET NUMBER SET DESCRIPTION BP #4.1 - Parking Garage & Skybridge Arch / MEPT / Interiors Package PROJECT NO.DATE MSKTD & Associates 12/12/19 1/29/2020 10:29:54 AMTECHNOLOGY SITE PLAN T1-00 10776 and 10777 Illinois StreetCarmel, IndianaFranciscan OrthopedicCenter of Excellence18004130.00 01-23-20A Project for:8900 KEYSTONE XING SUITE 210 INDIANAPOLIS, IN 46240 317.848.5045 FAX: 317.844.2201 www.imegcorp.com N O R HT 1" = 40'-0"1 TECHNOLOGY SITE PLAN GENERAL NOTES : 1. REFER TO T0-00 FOR TECHNOLOGY SYMBOL LIST AND GENERAL TECHNOLOGY INSTALLATION NOTES. 2. REFER TO T9-00 FOR GENERAL TECHNOLOGY EQUIPMENT SCHEDULE. KEYNOTES: 1. (1) 3" CONDUIT WITH (1) 3 CELL INTERDUCT. 2. (1) 2" CONDUIT. 3. REFER TO 3/T8-10 FOR EMERGENCY CALL STATION FOOTING DETAIL AND 4/T8-10 FOR EMERGENCY CALL STATION DETAIL. INSTALL SC-MED-1 INSIDE EMERGENCY CALL STATION. 4. EXISTING CONDUIT AND HANDHOLES INSTALLED IN BP#5. REFER TO T1-0 IN BP#5 DRAWING SET FOR MORE INFORMATION. 5. (1) 3" CONDUIT WITH (2) 3 CELL INTERDUCT. 6. ALTERNATE SA-3: PROVIDE (2) EMERGENCY CALL STATION AROUND THE WALKING PATH. 7. ALTERNATE SA-4: PROVIDE (2) EMERGENCY CALL STATIONS IN THE NORTH PARKING LOT. # REV. DATE 1 ASI #9 - BP4.1 1/29/2020 1