Loading...
HomeMy WebLinkAboutM-000 Mechanical General Notes, Symbols, and AbbreviationsABBREVIATIONS AND TERMS e �IAMETER, PHASE ET EXPANSION TANK OAT OUTSIDE AIR TEMPERATURE (°F) 'F pEGREES FAHRENHEIT EW EMERGENCY EVEWPSH OB� OPPOSED BLA�E �AMPER NC AIRCONDITIONING EWC ELECTRICWATERCOOLER 0� OUTSIDEDIAMETER,OVERFLOW�RAIN ACC AIRCOOLEDCONDENSER EWT ENTERINGWATERTEMPERATURE(°F) OF/CI OWNERFURNISHED/CONTRACTORINSTALLED ACCU AIRCOOLEDCONDENSINGUNIT EXH EXHAUST OSD OPENSITEORAIN AD AREA DRAIN, ACCESS DOOR EXIST EXISTMG OZ OUNCE AFF ABOVEFINISHE�FLOOR F FURNACE P PUMP PFMS PIRFLOWMEASURIN6STATION F&T FLOPTAN�THERMOSTATICSTEAMTRAP PBD PARALLELBLA�EDAMPER AGA AMERICANGASASSOCIATION FW FLOORCLEANOUT PC PWMBMGCONTRACTOR AHU AIRHPNDLINGUNIT FW FANCOILUNIT PD PRESSUREDROP AL ACOUSTICALLVLMED.ALUMINUM FD FLOOR�RnIN,FlREDAMPER PE PNEUMATICELECTRIC AMB AMBIENT F�C FIREDEPARTMENTCONNEQION PH PHASE ANSI AMERICAN NATIONAL STAN�ARDS INSTITUTE FDTN FOUNDATION PIV POST INDICATOR VALVE AO ANALOGOIITPUT FE FIREE%TINGUISHER PPM PARTSPERMILLION AP PCID PROOF, FCCESS PANEL FHC RRE HOSE CABWET PRV PRESSURE REDUCMG VPLVE APD AIR PRESSURE DROP QN. WG) FLR FLOOR PSI POUNDS PER SQUARE INCH ARCH ARCHITECT FM FACTORYMUTUAL PSIA POl1NDSPERSQUAREINCHAB50WTE ARI PIR CONDITIONMG AND REFRIGERATION WSTITUTE FOV FUEL OIL VENT PSIG POUN�S PER SQUARE INCH 6AUGE ARV AIRRELIEFVALVE FPM FEETPERMINl1TE PTAC PACKAGEDTERMINALAIRCONDITIONER AS AIRSEPARATOR FPVAV FANPOWEREDVAVUNIT PVC POLYVINVLCHLORIDE ASHRAE AMERICANSOCIETYOFHEATING,REFRIGERATING FS FLOORSINK R REGISTER NNDPIRCONDITIONINGEN6INEERS FSC RRESUPPRESSIONCONTRACTOR R12 REFRI6ERANT�12,22,ETC.) ASME AMERICAN SOCIETV OF MECHANICAL ENGINEERS F5� COMBINATION FIRE/SMOKE �AMPER RA RETl1RN AIR ASPE AMERICANSOCIETVOFPLUMBINGENGWEERS FT FOOT,FEET RADN RA�IATION PSTM AMERICANSOGETYPoRTESTMGANDMATERIALS RG FOOTING RPT RETURNAIRTEMPERATURE�°F) ATM ATMOSPHERE FTR FINNEDTIIBERADIATION RCP REINFORCEDCONCRETEPIPE AUTO AUTOMATIC G NATURALGAS R� ROOF�RAIN AVG AVERAGE GA GAGEORGAUGE REV REVOLUTIONS AVS ACIDVENTSTACK GAL GALLON RF RETURNFAN AW ACIDWASTE GC GENERALCONTRACTOR RG RETURNGRILLE AWWA AMERICANWATERWORKSASSOCIATION GIV GRAVITYINTAKEVENTILATOR RH RELATIVEHl1MI�ITY.ROD�INGHOLE BD BUTfERFLV �AMPER GP� GALLONS PER �AY RM ROOM BDD BACKDRAFT DAMPER GPH GALLONS PER HOUR RP RADIANT PANEL BE BOTTOM ELEVATION GPM GALLONS PER MINUTE RPM REVOLUTIONS PER MINUTE BF BARRIER FREE GR GRILLE, GRAINS RPS REVOLUTIONS PER SECOND BFC BELOWFINISHEDCEILING GRV GRAVITYRELIEFVENTILATOR RTU ROOFTOPUNIT BHP BRAKE HORSEPOWER GT GREASETRAP RV RELIEFVALVE,ROOFVENT BL�G BUILDMG HB HOSEBIBB SA SUPPLVAIR BOD BOTTOM OF DUCT H� HEA� (FT.) SAN SANITARV BOP BOTTOM OF PIPING Hg MERWRV SD SUPPLY DIFFUSER, SMOKE DAMPER BSMT BASEMENT HHWP HEATINGHOTWATERPIIMP SEER SEASONALENERGYEFFICIENCYRATIO BT BATHTUB HO HUBOURET SF S�UAREFOOT,SUPPLVFAN.SAFEiVFACTOR BTM BOTTOM HORIZ HORIZONTAL SG SUPPLVGRILLE BIUH BRITISHTHERMALUNITPERHOUR HP HORSEPOWER,HEATPUMP SH SHOWER CA COMPRESSEDAIR HR HOUR(5) SK SINK CAV CONSTANTAIRVOLUME HRTU HEATINGONLVROOFTOPUNIT SMACNA SHEETMETALANDAIRCONDITIONING CB CATCHBFSIN HX HEATEXCHANGER CONTRACTORSNATIONPLASSOCIqTION CCW COUNTERCLOCKWISE Hz HERTZ SP STATICPRESSURE C� CONDENSATEDRAIN IB INVERTEDBUCKETSTEAMTRAP SPEC SPECIFlCATION CO CARBONDIOXIDE ID INSIDEDIAMETER SQ Spl1ARE CF CEILINGFAN IE INVERTELEVATION SR SUPPLYREGSTER CFM CUBICFEETPERMINUTE IN INCH WCHES SRV SAFETVRELIEFVALVE CH CHILLER INT IMERIOR 55 SERVICESINK,STAINLESSSTEEL CHWP CMLLEDWATERPUMP INV WVERT STD STANDARD Q CASTIRON IPS INTERNATIONALPIPESTAN�AR� SV STEAMVENT CMP CORRUGATE�METALPIPE IW INDIRECTWASTE TCC TEMPERATURECONTROLCONTRACTOR CO CLEANOUT K KELVIN TCP TEMPERATUREWNTROLPANEL COMPR COMPRESSOR KEC KITCHENEQUIPMENTWNTRPCTOR TD TEMPERATURE�IFFERENCE COND CONDENSER kW KILOWATT TE TOPELEVATION CONV CONVECTOR LAB LABORATORV TEMP TEMPERATURE CP CONDENSATEPUMP LAT LEAVMGAIRTEMPERATURE(`F) TF TRANSFERFAN CPVC CHLORINATEDPOLYVINVLCHLORI�E LAV LAVATORV TG TRANSFERGRILLE CT COOLINGTOWER LBS POUNDS TMV THERMOSTATICMIXINGVALVE CU CONDENSINGUNIT LD LWEARDIFFUSER TONS TONSOFREFRIGERATION CUH CABINETUNITHEATER LP LIQUIDPETROLEUM TP TRAPPRIMER CUV CLASSROOMUNITVENTILATOR LTG LIGHTMG TRANS TRANSITION W CONTROLVALVE LWT LEAVMGWATERTEMPERATl1RE(`F) TS TAMPERSWITCH CW CLOCKWISE MA MIXEDAIR TSP TOTALSTATICPRESSURE IN.WC. ( ) CWP CONDENSERWATERPUMP MAT MIXEDAIRTEMPERATURE(°F) TXV THERMALEXPANSIONVALVE aB �EQBEL MAX MPXIMUM TYP TVPICAL �B �RV BULB M8 MOP BASIN UCD 11NDERCUT DOOR DF �RINKING FOUNTAIN MBH THOUSAND BN PER HOUR UH UNIT HEATER �G �OORGRILLE MC MECHANICALCONTRACTOR UL UN�ERWRITERSLABORATORIES �H �UCTHEATER MCA MINIMUMCIRCUITAMPS UON UNLESSOTHERWISENOTED DI �IGITALINPUT MCC MOTORCONTROLCENTER UR URINAL DIA �IAMETER MD MOTORIZED DAMPER 11S 11P STREAM DIFF �IFFUSER MFR MPNUFACTURER UV UNINENTILATOR DN �OWN MH MANHOLE V VOLTS,VENT DO �IGITPLOUTPUT MIN MINIMUM VAC VACUUM �S �OWNSPOUT,DOWNSTREAM MISC MISCELLANEOUS VAV VARIABLEAIRVOLUME �W �ISTILLEDWATER MS MOPSMK VB VACUUMBREAKER DWG �RAWING MTD MOUNTE� VD VOLUMEDPMPER DWH �OMESTICWATERHEATER MV MANl1ALVENT VEL VELOCITY �NN �RAIN,WASTEBVENT N NITROGEN VERT VERTICAL �X �IRECTE%PANSION NA NOTAPPLICABLE VF VENTILATIONFAN EA EXHAUST AIR NC NOISE CRITERIA. NORMALLY CLOSED VF� VARIABLE FREQUENCV �RNE EAT EMERMGAIRTEMPERATURE(°F) NEC NATIONALELECTRICCODE VTR VENTTHROUGHROOF EC ELECTRICALCONTRACTOR NFC NATIONALFIRECODE VUV VERTICALUNITVENTILATOR ECO EXTERIORCLEANOUT NFPA NATIONALFIREPROTECTIONASSOCIATION W WASTE,WATT E�R E�UIVALENTDIRECTRA�IATION NFWH NON-FREEZEWALLHVDRANT WC WATERCOWMN EER ENERGYEFFICIENCYRATIO NIC NOTINCONTRACT WB WETBULB EF EXHAUSTFAN NO NORMALLVOPEN,NITROUSOXIDE WC WATERCLOSET EFF EFFICIENCY NOM NOMINAL WCO WALLCLEANOUT EG EXHAUST GRILLE NPW NON-POTABLE WATER WH WALL HV�RANT EL ELEVFTION NTS NOT TO SCALE WPD WATER PRESSURE DROP (FT. H�.) EOM ENDOFMAINDRIP 0 OXVGEN WSHP WATERSOURCEHEATPIIMP ES EMERGENCY SHOWER OA OUTSIDE AIR VD VARD DRAIN ESP EXTERNALSTATICPRESSUREQN.WG.) OAI Ol1TSIDEAIRINTAKE RELEA5E0 FOR HIGH PRESSURE STEAM (>61 PSIG) MEDIUM PRESSURE STEAM (16-60 PSIG) LOW PRESSURE STEAM (q6 PSIG) HIGHPRESSURECONDENSATE MEDIUM PRESSURE CON�ENSATE LOW PRESSURE CONDENSATE BOILER BLOW DOWN 801LER FEED PUMPED CONDENSATE VAWUM PUMP DISCHARGE HUMI�IFICATION MAKE UP WATER AIR RELIEF VENT PIPING LINE SYMBOLS HPS MPS LPS _ - - - - _ HPC _ - - - - _ _----_MPC_----_ _ - - - - _ LPC _ - - - - _ BBD BF PC VPD H MU _ - - - - _ ARV _ - - - - _ ST - - - - - - pp - - - - - - SG FM AW - - - - - _ pV _ - - - - _ D IW PD HEAT RECLAIM PIPING HEATING WATER SUPPLY HEATING WATER RETURN REFRIGERANTDISCHARGE REFRIGERANT SUCTION REFRIGERAM LIQUID REFRIGERANT HOT GAS BRME SUPPLY BRINE RETURN CONDENSER WATER SUPPLV CONDENSER WATER RETURN CHILLE� WATER SUPPLV CHILLE� WATER RETURN �VALTEMPERATURESUPPLV �VALTEMPERATURERETURN HEAT PUMP WATER SUPPLY HEAT PUMP WATER RETURN GLVCOL HEATWG SUPPLY GLVCOL HEATWG RETURN FUEL OIL SUPPLV FUEL 0'L RETURN CONSTRUCTION Suhjec� �o compliance with all regula�ions 04 S�a�e antl Local Codes City of Carmel �un��V l�rcNal�l.�� � HR HHS HHR R� RS RL RHG BS 8R CS CR CWS CWR DTS DTR HPWS HPWR GHS GHR FOS FOR FOV co STORM DRAIN FOOTMG/FOUNDATION DRAIN SANITARV WASTE (W) SANITARV GREASE SANITARV FORCED MAIN SANITARV VEM (VJ ACID WASTE ACID VENT �RAIN INDIRECT WASTE PUMP �ISCHARGE �OMESTIC COL� WATER (CW) �OMESTIC HOT WATER SUPPLY (HW) �OMESTIC HOT WATER RETURN (HWR) 100°F HOT WATER 100°F HOT WATER RETURN NON�POTABLE WATER �RINKING WATER SUPPLV �RINKING WATER RETURN SOFT WATER CHLORINATE� WATER �ISTILLED WATER �EIONIZE� WATER FIRE SUPPRESSION NATURAL GAS (WC OR PSIG) GAS VENT LIQUID PETROLEUM MEDICAL COMPRESSE� AIR (WC OR PSIGJ MEDICALVACUUM OXVGEN NITROGEN NITROUS 0%IDE CARBON DIOXIDE WET VACUUM CLEANING �RV VAW UM CLEANING COMPRESSE� AIR (WC OR PSIGJ TEMPERED WATER SUPPLY TEMPERED WATER RETURN -100°F - - 1a0°F - - NPW - — ows — - DWR - - SW - -CL- - DI - -�E- G - - - - - - �y - - - - - - LP MA MV 0 N NO COz WVC DVC A TWS iWR PIPING IDENTITY SYMBOLS FLOW DIRECTION ARROW, PITCH DIRECTION ARROW � � PIPE RISE � : PIPE DROP PIPE CAP PIPECONTINUES�REFERENCEELSEWHERE) — PIPE GUIpE 3E PIPEANCHOR — REXIBLE CONNECTOR — EXPqNS10N COMPENSHTOR I I I I EXPANSION LOOP DI '� I CONCENTRIC, ECCENTRIC RTfINGS �I� III� UNION,FLANGEDUNION D4 GHTE VALVE � BALLVALVE CW GLOBEVNWE 'r BUTfERRVVALVE '�� PLUGVALVE N CHECKVAWE � PRESSUREREDUCMGVNWE REDUCED PRESSURE BACKFLOW PREVENTER � � �OUBLECHECKBACKFLOWPREVENTER O~ �OUBLE �ETECTOR CHECK VALVE PSSEMBLY � NNGLEVALVE � RELIEFVALVE � VAWEWITHOUTSI�ESTEM&VOKE I�c�I Vel PNEUMATICNVO-WAVCONTROLVALVE C�I PNEUMATICTHREEWHYCONTROLVALVE � ELECTRICTWO-WAYCONTROLVALVE � ELECTRICTHREEWAVCONTROLVNLVE � SOLENOID VALVE Q FLOW SWITCH Q PRESSURESWITCH Q N�UASTAT ",� ORIRCEFLOWMETER G'J VENTURI FLOW METER �� TURBWEFLOWMETER �I CALIBRATE�BALANCEVALVE � NUTOMATIC FLOW CONTROL VALVE STRHWER STRHWER WITH CHPPED BLOWDOWN J � MNNUALAIRVENT Q NUTOMATICAIRVENT g VACUUMBREAKER TEMPERATUREIPRESSURETAP 4 THERMOMETER Q PRESSUREGAU6E � Fa, STEFM TRAP WITH DESI6NATION � REFRIGERATIONSIGHTGLASS � � NIRFlLTEWDRYER � REFRI6ERATIONTHERMNLEXPqNS10NVPWE � INLWEPUMP �_ �IFFERENTINLPRESSURETRANSMITTER T WHA-A �ryATERHqMMERARRESTERWITH$CHE�ULETVPE �7 FD P-TRAP AND RISER 7 � 2"Fp-1 FLOOR �RHIN WITH SIZE & SCHE�ULE TVPE 'I CO ENDOFPIPE0.ENNOUT O FCO FLOOR CLEANOUT = WCO �ryq��CLEANOUT ^ EXTERIOR0.EHNOUTORRODDINGHOLE ECO TMV-1 THERMOSTATICMIXINGVAWEWITHSCHE�ULETVPE }-FHB4 }-FWH4 HOSE6IBB,WALLHVDRNNTWITHSCHEDULETVPE 'Om , WATERMETER 'O� GASMETER OJ"RD O J"OFD ROOF �RAIN, OVERFLOW �RAIN WITH SIZE � POSTINDICATORVALVE � FlREDEPARTMENTCONNECTION VALVE TNMPER SWITCH � UPRIGHTSPRINKLERHEAD �/ � PEN�ANTSPRINKLERHEAD �/ � �RVPENDANTSPRINKLERHEAD � CONCEALE�SPRINKLERHEAD p SI�EWALLSPRINKLERHEAD HVAC IDENTITY SYMBOLS RECTANGULAR DUCTWORK FLAT OVAL DUCTWORK ROUN� SPIRAL �UCTWORK 24112 �ESIGNATION IN INCHES, RRST ZQm pESIGNATION IN INCHES Z4��z a �ESIGNATION IN INCHES, RRST �IMENSION IS SIDE SHOWN �IMENSION IS SIDE SHOWN � RECTANGULARSUPPLVAIR. (�� ROUNOSPIRALSUPPLVAIR. �Y � FLATOVALSUPPLVAIR. OUTSIDEAIRDl1CTWORKRISE `Ci' �J Ol1TSIDEAIRDl1CTWORKRISE C_Y�J OUTSIDEAIRDl1CTWORKRISE RECTANGULAR SUPPLV AIR, ROUND SPIRAL SUPPLV AIR, �� FLAT OVAL SUPPLV AIR, )'� OUTSIDEPIRDUCNJORK xyi OUTSIDENIRDUCNJORK x`-yJ OUTSIDENIRDUCNJORK �ROP �ROP �ROP � RECTANGULARRETURNAIR. �Q ROUNDSPIRALRETURNAIR, �Q FLATOVALRETURNAIR, TRANSFERAIRDUCTWORK `CL-U TRANSFERAIRDUCiWORK CJ� TRANSFERAIRDUCiWORN RISE RISE RISE RECTANGULARRETURNAIR, ROUNDSPIRALRETURNAIR, �� FLATOVALRETURNAIR, �� TRANSFERAIRDUCiWORN ri TRANSFERAIRDUCiWORN .`-yJ TRANSFERAIRDUCiWORN �ROP �ROP �ROP � ROUND SPIRAL EXHAUST RECTANGULAR EXHAUST AIR, FLAT OVAL EXHAUST AIR, RELIEFAIRDUCiVJORKRISE AIR,RELIEFAIRDUCTWORK RELIEFAIRDUCTVJORKRISE RISE ROUND SPIRAL EXHAUST RECTANGULAREXHAUSTAIR, n �� FLATOVALEXHAUSTAIR, '�� RELIEFAIRDUCTWORKDROP '�v� OROPELIEFAIRDUCTWORK <C�J RELIEFAIRDUCTWORKDROP AL SS OTEEUMINUMOSTAWUESSD R� pREC IONOFROW �� �RECTONKOROP�IN Z� OF FLOWON ING� RECTIONE � � RECTION OF ROWE AIR IN � N D REOTION OF F IOWA R � TRANSITRONDUCT �� TRANSITIONCDUCT � FEATOVALD CT�RANSITION I� I�� VOLUMEDNMPER �� NCCESSDOOR �� �UCTWORKCAP I�� ACCESSZDOOR MPER WITH � �OOR AMPER WITH ACCESS so ACCESS DOORR WITH eoo ACCESS D ppAMPER WITH I—y—I WITH ACCESS DOORG STATION rw W TH ACCESS DOORMPER I—y—I ACCESS DOORNSOR WITH I—y—I ACCESS DOOR SENSOR WITH so ACCESS DOORTOR WITH �UCTWORK LINING OR � M NCHESESSURECHANGE �I� CONNECTIONTWORN � �ESIGNATIONSHOWNORK. FREEAREA � OS°BEVELEDFITTMGFOR � qqDIUSDUCTWORKELBOW RECTANGULARTO (CENTERLINERADIU51SxW) � SOUN�ATTENUATOR RECTANGIILAR Dl1CTWORK � RECAN�IILARD�COTWRK � WDHTIIRNNGV�AESLBOW � ELBOWDOUCTWORK J�� CONICAL FITTING FOR �� �r� � ROUND OR FLAT OVAL TO � WVE RADIUS �UCTWORK � MITERED DUCTWORK ELBOW ROUN� OR FLAT OVAL ELBOW WITH TIIRNING VANES �UCPNORK STAN�OFF DAMPER FOR ,.!� p5° RADIUS DUCiYVORK TRANSFER AIR ELBOW WITH � ROUNDTORECTANGULAR �`(� ELBOW(CEMERLMERA�WS � DUCTWORKSTUBSFOR �UCTWORK,LOWPRESSURE ��I iSxW SOl1NDATTENUATION �VOPNORK � � � SPIN-IN FITTING FOR ROUNDTORECTANGULAR � CEILINGPANELSUPPLVAIR � ROUN�SUPPLVAIR �UCTWORK, LOW PRESSURE �IFFUSER �IFFUSER �UCPNORK FLEXBLE DUCT CONNECTION T RETURN AIR. EXHAUST AIR, l�mrm+r �IFFUSER,MF%SIXFEET. � RECTANGULARSUPPLVAIR � TqqNSFERAIRREGISTEROR 5--�i�'i� LONGER R11N5 USED IN REGISTER GRILLE RESI�ENTIFL AS SHOWN. SI�EWALL RETURN AIR, SI�EWALL SUPPLV AIR LINEAR SLOT SUPPLV AIR � REGISTERORGRILLE �" EXHPUSTAIR,TRANSFERNIR � pIFFUSER REGISTER OR GRILLE THERMOSTATWITH � �r PSSOCINTEDE�UIPMENT is TEMPERATURESENSOR �OORGRILLEORUNDERCUT I*u�2aai �ESIGNATION(OPTIONAL) � �OOR HUMIDISTATWITH � CEILING�ESTRATIFICATION � ASSOQPTE� E�UIPMENT CO z CARBON DIOXIDE SENSOR FAN I*u�2�4� �ESIGNATION(OPTIONAL) o TEMPERATURECONTROL VARIABLEFREpUENCY CENTRIFUGALROOF PANEL 0 �RNE � EXHAUSTFAN SJ-�ii WITHACCESSDOORaIL �� HVDRONICREHAITCOIL �ILII� INLWEFNN ELECTRICREHEATCOIL {, TERMINALUNITWITH ��� SERIESIPARALLELFAN � WITHACCESSDOOR `�'� ELECTRICREHEATCOIL POWEREDTERMINAWNIT ipi BASE MOUNTED PUMP � UNINENTILATOR F� UNIT HEATER �� HEATEXCHANGER � AIRSEPARATOR o RNNEDTUBERADIATION REFERENCE SYMBOLS SECTION INDICATOR: REFERENCE SECTION LOCATION THROUGH AN AREA KEVNOTE IN�ICATOR'. REFERENCE SHEET KEYNOTE LOCATION FOR FOR AD�ITIONAL INFORMATION. ADDITIONAL INFORMATION. SECTIONLOCPTION BEVONDAREA KEVNOTEINDICATORS INDRAWINGMODULE EXTENSION NUMERIC X p�AN CHARAQER POINTLEADER X X X RELATESTOITEM X AREALEA�ER SECTION LOCATION AT SUBSET SHEET LINE LEADER �ETAILINOICATOR: REFERENCEDETAILLOCATIONFORA�DITIONAL �RAWINGBLOCKTITLE REFERENCEDRAWINGMODULELOCATIONFOR WFORMATION. INDICATOR: ADDITIONALINFORMATION. LARGE SCALE VIEW DETAIL LOCATION IN pRAWING MODULE LOCATION LOCATIONINDRAWING DRAWINGMODULE (IpENTIFVINGLOWERLEFTOFMULTIPLE MODULE ���\ MODULES) ��__�\ X � ; X % �� X DRAWING BLOCK TITLE m X � � X \ / SCALE' 1I8'•= 1' 0•' 0 4' B' ifi' J , , �,__; � ! NUMERICSCALE/GRAPHICSCALE N�/ LARGESCALEVIEW DETAILLOCATIONAT LOCATIONATSUBSETSHEET SUBSETSHEET MATCH LINE INDICATOR'. REFERENCE SHEET LOCATION FOR AD�ITIONAL REVISION INDICATOR: REFERENCE TITLE BLOCK LOCATION FOR A�DITIONAL WFORMATION. WFORMATION. FLOORPLANOVERLAP BEYON�AREA REVISIONINDICATOR EXTENSION �1\-`--^� SEE XXXX X REFERTOADDITIONAL PLAN SHEET FOR CONTINUATION � REVISION CLOUD EOUIPMENT INDICATOR'. REFERENCE SCHE�ULE LOCATION FOR AD�ITIONAL �IFFUSER. GRILLE. REFERENCE SCHE�ULE LOCATION FOR A�DITIONAL WFORMATION. REGISTERINDICATOR: WFORMATION. TU-XL##—NUMERICCHARACTERRELATESTOITEM MULTIPLIER \\(OPTIONAL) \ SCHEDULE TYPE ALPHANUMERICCHARACTERRELATES X % TO BWLDING LEVEL (OPTIONAL) ALPHANUMERIC CHARACTER RELATES � TO ASSOCIATE� AIR HANDLER (OPTIONAL) AIRFLOW (CUBIC FEET PER MINUTE) E�UIPMENTTVPE GENERAL HVAC NOTES A. ALL WORK SHALL BE IN ACCORDANCE WITH THE BEST aUALITY STAN�AR�S OF THE TRAOE, AND SHALL CONFORM WITH ALL FE�ERAL, STATE AN� LOCAL CODES AND STAN�AR�S. THE SAME ARE MADE A PART OF THESE CONTRACT �OCUMENTS AS IF REPEATED HEREIN. B. CONTRACT�OCUMENTSCONSISTOFBOTHTHEPROJECTMANUALAND �RAWINGS, AND BOTH ARE INTEN�ED TO BE COMPLEMENTARV. ANVTHMG APPEARING ON EITHER MUST BE EXECUTE� THE SAME AS IF SHOWN ON BOTH. G THE CONTRPCTOR SHALL MCLUDE IN BID PROPOSAL ALL WSTS REQUIRED TO COMPLETELY AN� PROPERLV INSTALL ALL WORK REQUIRE� PoR THE PROJECT, AN� SHALL EXAMME THE SCOPE OF WORK OF OTHER TRA�ES PRIOR TO SUBMITTING A BIO PROPOSAL. D. CONSTRUCTION DOCUMENTS SHALL BE FOLLOWE� AS CLOSELV AS POSSIBLE, HOWEVER, SVSTEMS HAVE BEEN SHOWN DIAGRAMATICALLY AN� IN SOME CASES. ENLARGED FOR CLARIN. ANY OFFSETS, ADDITIONAL FITTINGS. AND/OR APPURTENANCES REQUIRE� TO PROVI�E A COMPLETE AN� COORDINATE� SYSTEM SHALL BE BORNE BY THE CONTRACTOR. E. THEENGINEERING�RAWINGSAREOFEQUALIMPORTANCEWITHTHE ARCHITECTURAL DRAWMGS IN DEFINING THE WORK OF THE CONTRACT �OCUMENTS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO CHECK WITH THE ARCHITECTURAL DRAWINGS BEFORE THE INSTALLATIONOFENGWEERINGWORK. SHOULDTHEREBEA �ISCREPANCV BETWEEN THE ARCHITECTURAL DRAWINGS AN� THE ENGMEERING DRAWINGS THAT WOULD CAUSE AN AWKWARD OR IMPROPER WSTALLATION, THE DISCREPANCV SHALL BE BROUGHT TO THE ARCHITECTS/ENGW EERS ATTENTION FOR CLARIFlCATION PRIOR TO INSTALLATION OF SAID WORK. ANY WORK INSTALLED IN CONFLICT WITH THE ARGHITECTURAL ORAWINGS SHALL BE W RRECTE� BY THE CONTRACTOR AT HIS EXPENSE AND AT NO ADDITIONAL COST TO THE OWNER OR ARCHITECT/ENGWEER. E DONOTSCALETHEORAWINGS.THEDRAWMGSARENOTNECESSARILY TOSCALE THECOMRACTORSHALLVERIFVALLCONDITIONSAN� DIMENSIONS AT THE J08 SITE PRIOR TO THE START OF CONSTRUCTION. IF DISCREPANCIES ARE PoUND. THE ARCHITECT/ENGINEER SHALL BE NOTIFIED FOR CLARIFICATION BEFORE COMMENCINGTHEWORK EXPLICITDIMENSIONSSHALLHAVE PRECEDENCE OVER SCALE. G. CONTRACTORSHALLRELDVERIFYALLEXISTINGCONDITIONSPRIORTO BIDDING OR BEGINNING WORK ON THIS PROJECT. H. �ETAILSNOTSHOWNARESIMILARMCHARACTERTOTHOSESHOWN. WHERE SPECIFIC DIMENSIONS, DETAILS OR DESIGN INTENT CANNOT BE �ETERMMED, CONSULTTHE ARCHITECT/EN6WEER BEFORE PROCEEDING WITH THE WORK. I. ANVDETAILS,SYSTEMSANDIORMATERIALSWHICHAREPROPOSEDTO BE CHANGED MUST RRST BE REVIEWE� BV THE OWNER AND ARCHITECT/ENGINEER PRIOR TO THE PREPARATION OF SHOP DRAWINGS. J. REFERTOMANUFACTURER'SINSTALLATIONINSTRUCTIONSFND TEMPLATE ORAWINGS FOR ALL MECHANICAL EpUIPMENT SUPPORTS. BOLTSETfINGTEMPLATES,ISOLFTORS,SPRINGISOLFTION,ETC.,NOT SHOWN ON THE DRAWINGS. K. REFER TO ARCHITECTURAL REFLECTED CEILING PLANS FOR EXACT LOCATION OF CEILMG MOUNTED MATERIALS INCLU�ING ALL DIFFUSERS, GRILLES. AN� REGISTERS. L CONTRACTORSHALLCLOSEALLUNUSEDOPENINGSINEXISTING DUCTWORK. M. ALLDIICiWORKDE5IGNATI0N5REFERTONETFREEAREAIN5IDETHE DUCTWORK N. VOWME DAMPERS SHALL BE LOCATED AT BRANCH CONNECTION TO THE MAIN. 0. A MAXIMUM OF SIX FEET OF FLEXBLE �UCTWORK MAV BE IISED AT ALLSUPPLYDIFFUSERS. BRANCHDUCTWORKTODIFFUSERSHALL BE SAME SRE AS �IFFUSER INLET UNLESS SPECIFICALLY LABELED OTHERWISE. REFER TO DIFFUSER SCHEDULE FOR INLET SIZES. AV01� SHARP BEN�S IN FLEXIBLE DUCTWORK WHICH MAY CAUSE EXCESSIVE NOISE. P. BRANCHDUCiWORKTOTERMINALUNITSSHALLBESAME51ZEA5 TERMINAL UNIT INLET UNLESS SPECIRCALLY LABELE� OTHERWISE. REFER TO TERMINAL UNIT SCHEDULE FOR WLET SIZES. NOTATION DESIGNATORS GENERALNOTES: NOTESTHATAPPLVEQUALLVTOALL�ISCIPLMES WITHIN THE DRAWING SET. GENERAL NOTESTHATAPPLYEQUALLVTOALLSHEETSWITHIN MECHANICALNOTES'. THEDISCIPLINE. GENERALSHEET NOTESTHATAPPLYONLYTOTHESPECIFICSHEET NOTES: ON WHICH THEY APPEAR. SHEETKEVNOTES'. NOTESTHATAPPLVONLYTOTHESPECIFICSHEET ON WHICH THEY APPEAR AN� USE A KEVNOTE IN�ICATOR TO I�ENTIFY ITEMS. DISCIPLINE DESIGNATORS F000 FlRESUPPRE$$ION P-00� PLUMBING PD000 PLUMBING DEMOLITION PG00� PWMBINGGAS PS000 PWMBMGSANITARY PW000 PLUMBING WATER M-000 MECHANICAL MD0�0 MECHANICAL �EMOLITION MH0�0 MECHANICALHVAC MP000 MECHFNICPLPIPING SHEET TYPE DESIGNATORS 000 GENERAL (SYM60LS, ABBREVIATIONS, NOTES) 100 PLANS 200 ELEVATIONS 300 SECTIONS J00 LNRGE SCALE VIEWS (PLANS, ELEVATIONS OR SECTIONS) 500 DETAILS 600 SCHEDULES OR DIAGRAMS ]00 (USER DEFINE�) 800 (USER DEFlNE�) 900 3� REPRESENTATIONS QSOMETRICS) LINETYPE DESIGNATORS THW CONTINUOUS LMETYPE INDICFTE EXISTING ITEMS TO REMAIN. IMERMEDIATE DASHE� LWETVPE INDICATE EXISTING ITEMS TO BEREMOVED. — INTERMEDIATEORWIDECONTINl10U5LINETVPEINDICATENEW — ITEMS. THIN HALFTONE LINETVPE INDICATE ITEMS BY OTHER �ISQPLWE. � IN�ICATESPOINTOFNEWWNNECTIONIDEXISTING EOl11PMENT, PIPING OR MATERIALS. � INDICATES POINT OF DISCONNECTION TO E%ISTING E�UIPMENT, PIPING OR MATERIALS. � U W � O � a _ / � 2 � O � I J a a a I Q ` V+ Z O � Q � W � � � a � O J O � �` I � wn _ / � O � a Z � � � W � n W � O Z J J Q � O Z ,�verity E N G I N E E R I N G 9229 Delegates Row, Sui�e 150 Indianapolis. IN 46240 31]]062�]5 www.enveriryENG.com Engineec ,, ,�PE.... _..FO O e YE1041 418 3i,ipr; q.�. $T�TEOF � Developer: P E D C O R U':� Cve�ez DEVELOPMENT CO. Projecf �� U) N � M � O W � � � � � O � •� � � � = U 100% Construction Documents Set Issue Dale Shee� Issue Date OB/3111] 0&3111] Drewn By Checketl By JL RM Last Revision Date: Enverity Number' 14768 Shee� Ti�le: Mechanical General Notes, Symbols and Abbreviations Shee� Number: ' I 1 1� DATE: 06�� $ 2O