HomeMy WebLinkAbout7 MEP-1-MEP-1-Rev.0ELECiRICAL SPECIFlCATIONS 1. MATERIALS FURNISHED SHALL BE NEW, MATERIALS SHALL BE A MANUFACTURER'S STANDARD AN� EsraausHEo aRooucr uNEs, nNo sHa�� aE usrEo AND LABELED FOR THE APPLICATION BY UNDERWRITEft'S LABORATORIES (LLL), OR SHALL BE CERTIFlED BY OTHER APPROVED LABORATORY OR BE THE BUILDING OFFlCIAL HAVING JURISDICTION. 2. THE PLANS ACCOMPANYING THESE SPEQFICAiIONS ARE GENERALLY �IAGRAMMAiIC AN� �0 NOT SHOW ALL �ETAILS REQUIRED FOR THE COMPLETE WORK. ESTABLISH DETAILS OF THE WORK AS NECESSARY TO PROVIDE FOR THE COMPLETE INSTALLATION OF SYSIEMS AD MATERIAL. ARRANGE THE WORK SO AS TO AV01� INTERFERENCE WIiH O7HER BUIL�ING COMPONENTS OR SYSTEMS AS ACTUALLY INSTALLED. 3. COMPLY WI7H APPLICABLE OR NECESSARY JOB SAFETY PROVISIONS. 4. PROVIDE FOR SYSTEM RACEWAYS, OUiLET BOXES, PULC'WIRES" OR "CORDS', OUTLET BOX OPENINGS, BOX EXTENSIONS, DEDICAiE� RECEPTACLES, BACKBOARDS, Erc ns sPEaFiEo nNo iNoicnrEo. rE�EPHONE cne�E SHALL BE FURNISHED AND INSTALLED BY OTHERS. 5. ELECTRICAL SYSiEMS, EQUIPI�ENT, AND SUPPORTING SiRUCTURES SHALL BE COMPLETELY ANO EFFECTIVELY GROUNDED. BONDING JUMPERS SHALL BE PROVIDED WHERE NECESSARY. METAL ELECiRICAL ftACEWAYS AND FITTMGS, JOINTS AND CONNEC710NS AT EOUIPMENT SHALL BE NECHANICALLY AND ELECTRICALLY SECURED TO PROVIDE ON APPROVED EOUIPIAENT OR ENCLOSURES GftOUN�ING MEANS, EVEN WHEN NO OiHER SEPARATE GROUNDING MEANS ARE ALSO PROVIDED EITHER INHERENTLY OR BY BONDING. 6. WHERE GREEN GROUNDING CONDUCTORS ARE NOT INDICATE� SPECIFlCALLY FOR EACH BRANCH QRCUIT BY iHE �RAWMGS. PROVIDES FOR EACH RACEWAY A GREEN �12 GROUNDING CONDUCTOR IN ADDITION TO BRACH CIRCUIT CONDUCTORS INDICATED. 7.UNLESS O7HERW15E INDICAiED OR DIRECiED BY THE ARCHIiECT FOR SPECIAL APPLICAilONS. WIRING DEVICES SHALL BE INSTALLED WITH TOP-0E-BOX MOUNTING HEIGHTS ABOVE FlNISHED FLOORS BETWEEN 18 INCHES AND 48 INCHES, AS REQUIRED BY HANDICAPPED CODES. MOUNTING HEIGHTS FOR SPEQFlC DENCES SHALL BE AS SCHEOULE� BY THE PLANS. 8. ELECTRICAL CONDUCTORS SHALL BE COLOR CODED AS REQUIRED BY CODE. PHASE CONDUCTORS: RED: BWE, BLACK; NEUTRAL WHITE; EQUIPMENT GROUND: GREEN. 9. NOTIFY THE OWNER'S REPRESENTAiIVE OF ANY NON FUNCTIONING MATERIAL OR POIENTIALLY UNSAFE CONDITION WIiHIN THIS PROJECT SYSTEMS THAT IS OBSERVED DURING THE CONDUCT OF THE WORK. 10. WORK SHALL BE FURNISHE� AND INSTALLE� AS A MINIMUM IN ACCORDANCE WITH THE APPLICABLE REQUIREMENTS AND RECOMMENDATIONS OF THE LATEST LOCALLY ADOPTED EDITION OF CODES AND STANDARDS OF THE FOLLOWING: (1). NATIONAL ELECTRICAL CODE (NEC)-NFPA 70. (2). ENERGY CO�E - ASHRAE/IESNA 90.1. (3). LIFE SAFETY CODE-NEFPA 101. (4). OTHER NFPA STANDARDS: 90A AND 99. (5). GAC 120-3-20. (6). U.L STANDARDS AND LISTING REQUIREMENTS AND NEMA STAN�AR�S. (7). FEDERAL, STATE, AND LOCAL LAWS, ORDINANCES, CODES, AN� RULINGS OF BUIL�ING OFRCIALS HAVING JURIS�ICTION IN�IANA. 21. FIXTURE SUPPORTS AND HARDWARE SHALL BE Sl11TABLE METAL UNLESS OTHERWISE INDICATED. SUPPORT STUDS USED FOR INDOOR RXTURE OR COMPONENT SUPPORT SHALL BE GALVANIZED STEEL OR MALLEABLE IRON. 23. CONDUCTORS SHALL BE OF SOFT DRAWN, ANNEALED COPPER HAVING A WNDUCTIVITY OF NOT LESS THAN 98 PERCENT BY "ASTM" STANDARDS. 24. UNLE55 OTHERWISE REDUIRED BY CODE OR INDICATED: A. WNDUCTORS N0. 12 AWG AN� N0. 10 AWG SIZE SHALL BE souo. B. CONDUCTORS N0. 8 AWG SIZE AND LARGER SHALL BE STRANDED. 25. RIGI� STEEL AND IMC SiEEL CONDUIT SHALL BE HOT �IP GALVANIZED. STEEL EMT SHALL BE HOT DIP GALVANIZED OUTSIDE. AND ENAMEL OR GALVANIZED FlNISHE� WSIDE. 26. EMT COUPLINGS AND CONNECTORS SHALL BE METAL AND SET-SCREW TYPE. 30. FIXTURES SHALL BE INSTALLED IN ACCOft�ANCE WITH UL LISiING RESTRICTIONS AND LOCAL CO�ES AND ORDINANCES. 31. FIXTURES SHALL BE LOCATED IN A MANNER COORDINATED WITH ANY SUSPENDED ACOUSTIC CEILING PATTERN, AN� IN ACCORDANCE 'M7H PATiERNS AS SHOWN ON THE ARCHIiECNRAL �RAWINGS. 32 UNLE55 OiHERWISE REQUIRED BY CO�E OR FUNCTION OR INDICATED BY THE PLANS, CONDUCTORS FOR POWER AND LIGHTING BRANCH CIRCUITS SHALL BE �12 AWG. MINIMUM. 33. CONDUCTORS SHALL BE CONNECTED BY U.L APPROVED CONNECTORS. BRANCH CIRCUIT WIRING W 52E �8 SHALL BE CONNECTED BY CONNECTORS wITH LIVE SPRMG TENSION. 34. WIRING SHALL BE INSTALLED IN METALLIC, RIGI� TYPE RACEWAYS, UNLESS OTHERWISE INDICATED, SIZED PER "NEC". 35. RACEWAYS AN� CABLE SHALL BE RUN CONCEALEq EXCEPT THAT RACEWAYS DESIGNED ONLY FOR SURFACE MOUNTING AND RACEWAYS AND CABLE M EQUIPMENT ROOMS SHALL BE RUN EXPOSED; UNLESS OTHERWISE INDICATE�. CONCEALED CONDUIT RUN ABOVE THE CEILING LWE SHALL BE SUPPORTED INDEPENDENTLY OF CEILING WNSiRUCTION. WHERE CEILINGS OF THE LAY-IN TYPE lAAY BE USED. CON�UITS MUST BE INSTALLED HIGH ENOUGH TO PERMIT REMOVAL OF CEILING PANELS OR EQUIPMENT. 36. RACEWAY OR CABLE, ETC. THAT PENETRATES A FIRE BARRIER, SUCH AS RRE OR SMOKE RATED SLAB, WALL, CEILING, OR OTHER ELEMENT, SHALL BE MSTALLE� WITH MATERIALS AN� MEiHODS APPROVED PoR THE APPLICATION BY LOCAL BUILDING OFFlCIALS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR IDENTIFYING EACH FIRE BARRIER FORM iHE AR HIiECTURAL PLANS, AND FOR SECURWG APPROVAL OF MATERIALS AN� METH005 TO BE USED FOR EACH T1PE PENEiRATION. �pt3952.02; 37. UNLE55 OTHERWISE IN�ICATED, RACEWAYS SHALL BE AS FOLLOWS' A. CONCEALED INSIDE WHERE NOT W WET OR DAMP LOCATIONS AND NOT EXPOSED TO MECHANICAL INJURY. AND USE� FOR 120V�20A BRANCH CIRCUITS, T1PE MC CABLE; OTHERWISE ELECTRICAL METALLIC TUBING (EMT�. B. 7HROUGH TWO-HOUR RATED FlRE BARRIERS OR BUILDING EXTERIOR; GALVANIZE� RIGI� STEEL (GRS) CONDUIT MADE UP WAIER 71GHT. C. FINAL CONNECTION RACEWAYS IN DRY LOCATIONS SERVING LIGHiING FIXiURES, OR OTHER NON-MOTOR EOUIPMENT LIKELY TO REQUIRE MOVEMENT FOR A�JUSiMENT OR LIKELY TO TRANSMIT SHOCK OR VIBRATION INTO iHE RACEWAY SYSTEM, BUT NOT REQUIRING REXIBILITY FOR OPERATION, AND WHERE APPROVED PoR THE APPLICATION SHALL BE FLEXBLE METAL TUBING (FLEX) WHERE APPROVED FOR THE APPLICATION. 38. BO%ES SHALL NOT BE MSTALLED BACK-TO-BACK AND 11. THE WORK COVERED BY THIS SPECIFlCATION SHALL 7HRU-WALL TYPE BOXES SHALL NOT BE USED DUE TO INCLUDES PROVIDWG SUPERVISION, LABOR, SUPPLIES, 7qqN5MI5510N OF SOUN� OR HEAT AND SlAOKE. OFFSET TO MATERIALS (TO INCLUDE EQUIPMENT), TOOLS, SERVICES, MAINTAM FlRE RATING PER UL REQUIREMENTS. DOCUMENTA710N, TEST AND DEMONSiRATI0N5, CERTIFICAiES, AND DOLLAR COSTS REQUIRED TO 39. SUSPENDED CEILMG CONSTRUCTION SHALL NOT BE USED TO CONSTRUCT THE COMPLETE SYSTEMS AS SPECIFlED SUPPORT RACEWAYS, BOXES OR OTHER ITEI�S, EXCEPT AS ALLOWED HEREIN AN� AS SHOWN BY 7HE PLANS AN� OTHER BY CO�E, ACCEPiED BY iHE ENGMEER, AND ACCEPTED BY iHE RELEVANT DOCUMENTS. ARCHITECTIN WRI7ING FOR iHE SPEQFlC ITEMS TO BE SUPPOR7E�. 13. SERNCE EQUIPMENT SHALL BE PROVIDED RATED 40. COVER PLATES FOR FLUSH, DRY, ORDINARY LOCATIONS SHALL FOR BUILDING LOADS, WCLUDING INTERRUPTING BE STANDARD CONFIGURATION, ONE PIECE, STANDARD S2E PLATES RATINGS SERVICE EQUIPMENT SHALL BE SERVE� USING W�7ry MATCHING SCREWS, AND HAVING MATERIALS, STYLES, AND THE TYPE SERVICES ENTRANCE EQUIPMENT AS FlNISHES AS SELECTE� BY ARCHITECT. M�ICATED BY THE PLANS. 16 SWITCHES SHALL AS A MINIMUM BE "HEAVY-DUTY RATED, QUICK MAKE AND BREAK, SPECIFICATION GRA�E, SINGLE THROW DEVICES. 41. CONDUIT SYSTEM SHALL BE INSTALLED CONCEALED ABOVE CEILWG, ABOVE LOWEST POINT OF STRUCiURAL STEEL SYSTEM LOWER CHORD FOR HORIZONTAL Rl1NS INSTALL PARALLEL OR PERPEN�ICULAR TO S7RUCNRAL MEMBERS. 17. �ISiRI8UTI0N E�UIPMENT USING QftWIT BREAKER TYPE PROIECTIVE DEVICES SHALL USE BOLTED-ON OR "SOUARE D" I-LWE �EVICES. 18. DISTRIBUTION EQUIPMENT SHALL BE AS INDICATED AND AS MANUFACTURED BY GENERAL ELECTRIC, CUTLER/HAMMER, SQUARE-D, SBMENS. 19. PANEL BOARD MANS, SHALL BE COPPER WITH BRANCH DEVICE CONNECTIONS ARRANGED IN A VERiICALLY �ISTRIBUiE� CONSECUTIVE PHASE SE�UENCES SUCH iHAT ONE OR MULTIPLE POLES BREAKERS CAN BE MOUNTED IN ANY POSITION. A SOLID NEUTRAL BUS SHALL BE PROVIDED WITH FEEDER LUG AND WITH A SEPARATE SET-SCREW W TERI�INAL FOR EACH BRACH CIRCUIT POLE. 20. STARTERS AND DISCONNECT SWITCHES SHALL HAVE QUICK-I�AKE AND QUICK-BREAK MECHANISMS, AND BE FULLY ENCLOSED. RELEA5E0 FOR CONSTRIlCTION Su6jec��o compliance with allregula�ions of S�a�e antl Local Codes r City of Carmel �un��\i lo•rvalM��' MECHANICAL NOTES: 1. THE CONTRACTOR SHALL EXAMINE ALL OTHER SPECIFICATIONS, DRAWING AND ALL OTHER FEATURES OF BUILDING CONSTRUCTION WHICH MAY AFFECT HIS WORK AND BE GOVERNE� BY THESE SPECIFICATIONS, INCLUDING THE GENERAL CONDITIONS AND PARTICULAR INSTRUCTIONS TO ALL BIDDERS AND SUPPLIERS. 2 ALL WORK SHALL BE EXECUTED AND INSPECTED IN STRICT ACCORDANCE WITH ALL LOCAL CODES AND/ OR STATE CODES, LAWS, ORDANCES, RULES, AND REGULATIONS APPLICABLE TO THIS PARTICULAR CLASS OF WORK, AND EACH CONTRACTOR SHALL INCLUDE IN HIS PRICE ALL SERVICE CHARGES, FEES, PERMITS, ROYALTIES, TAXES, AND OTHER SIMILAR COST W CONNECTION THEREWITH. 3. PRIOR TO FABRICATION OF DUCTWORK, CONTRACTOR SHALL EXAMWE AND VEPoFY ALL CONDITIONS ABOVE AND BELOW THE CEILING WHICH MAY INTERFERE WITH THE DUCT SYSTEM AND NOTIFY THE ARCHITECTS OF ANY CONFLICT ENCOUNTERED. CONTRACTOR SHALL PROVIDE ALL OFFSETS ETC. WHICH MAY BE REQUIRED. 4. ALL SHEET METAL CONSTRUCTION SHALL BE IN STRICT ACCORDANCE WITH "SMACNA° LOW PRESSURE DUCT CONSTRUCTION STANDARDS. 5. TURNING VANES SHALL BE WSTALLED IN ALL BENDS GREATER THAN 30 DEGREES. 6. ALL DUCTS SHALL BE SUPPORTED WITH 1" WIDE, 16 GAUGE GALVANIZED SiEEL BANDS. 7. ALL RECTANGULAR DUCT SHALL BE INSULATED WITH A MINIMUM OF 1" INTERNAL LINER, 2 LB. DENSITY. ALL ROUND DUCT AND DIFFUSER TOP SHALL HAVE A MINIMUM OF 2" FOIL BACKED BLANKET TYPE INSULATION WITH ALL JOINTS BUTTED AND TAPPED. WSULATION "R" VAWES SHALL COMPLY WITH GOVERNING ENERGY EFFlCIENCY REQUIREMENTS. 8. ALL DUCT DIMENSIONS SHOWN ON PLANS ARE SHEET METAL DIMENSIONS. ALL OWANCE HAS BEEN MADE FOR LINER. 9. CONTRACTOR SHALL COORDINATE LOCATION OF ALL SUPPLY AND RETURN AIR REGISTERS, DUCT, GRILLES, AND DIFFUSERS WITH LIGHTS AND CEILING PATTERNS. 11. MOUNT iHERMOSTAT AT 48" MAXIMUM ABOVE THE FINISHED FLOOR. 12 PROVIDED U.LF.D. AT ALL DUCT OR AIR DISTRIBUTION PENETRATIONS OF RATED WALLS, FLOORS. OR CEILING ASSEMBLES W/ ACCESS. 13. PROVIDE CONDENSATE DRAIN W� TRAP AT UNITS WITH DRAIN TO OPN'G BY PLUMBING CONTRACTOR COORDINATE W/ PLBG. CONTRACTOR. 14. MECHANICAL CONT'R SHALL CONFER W/ ELECTRICAL CONT'R & COORDINATE ALL POWER REQUIREMENTS POINTS OR CONNECTION ETG COORDINATE W/ PLBG. CONTRACTOR TO INSURE PROPER CONDENSATE DRAWS. GENERAL PLUMBING NOTES 1. ALL PWMBING WORK SHALL COMPLY WITH iHE 2006 INiERNAiIONAL PWlABING CO�E WITH APPLICABLE STAiE AND LOCAL AMENDMENTS. ALL WORK SHALL 6E EXECUiED AND WSPECTED M S7RICT ACCORDANCE WI7H ALL LOCAL CODES AN�/ OR STATE CO�ES, LAWS, ORDANCES, RULES, AND REGULATIONS APPLICABLE TO THIS PARiICULAR CLASS OF WORK. EACH CONTRACTOR SHALL WCLUDE IN HIS PRICE, ALL SERVICE CHARGE$ FEES, PERMITS, ROYALTIES, TAXES, AND OTHER SIMILAR COSTS IN CONNECTION hIEREWITH. 2. ALL PIPING SHALL BE CONCEALED IN WALLS AND BEHIND FIXED FURNISHINGS UNLESS OTHERWISE INDICATED. 3. EXPOSED TRIM PIPING TO FlXTURES INCLUDING CW, HW, DRAIN, AND DRAIN TRAPS, SHALL BE PVC WITH PVC ESCUTCHEONS AT WALL PENETRATION. ALL OTHER EXPOSED PIPING TO BE MSTALLED PER SPECIFlCATIONS WITH ESCUTCHEONS. 4. SLEEVE OR CORE-DRILL FLOOR SLABS, WALL$ ETC. AS REQUIRED FOR PIPING AN� FlRE-STOP OPENING AROUND PIPE. VERIFY LOCAiION OF SiRUCNRAL BEAMS, JOISTS, ETG BEFORE �RILLING. 5. ALL OPENINGS IN DRAINAGE AND�OR VENT SYS7EM5 AS A RESULT OF WSTALLAiION ROUGH-IN SHALL BE PROTECiE� W1TH A TEST PWG THAT IS SECURELY LOCKED IN PLACE UNTIL FlNAL FlNISHED CONNECTIONS ARE INSTALLED. 7. PROVIDE CLEANOUTS AT THE END OF EACH HORIZONTAL RUN, AND AT 7HE BASE OF ALL VERTICAL WASTE AND DRAIN PIPES. CLEANOUTS SHALL BE OF THE SAME SIZE AS THE PIPES THEY SERVE. 8. ACCESS PANELS SHALL BE PROVI�E� WHERE CONCEALED WNTROL DEVICES, VALVES, ETG ARE CONCEALED WITHIN WALLS. WHERE ACCESS FOR ADJUSiMENT AND MAIMENANCE IS POSSIBLE 7HROUGH LAY-IN SUSPENDED CEILINGS, ACCE55 PANELS, ARE NOT REQUIRED. 9. ALL PIPING SHALL BE RUN PARALLEL TO BUILDING LMES AND SUPPORTED AND ANCHORED AS REQUIRED TO FAQLITATE EXPANSION AND CONTRACTION. 10.INSTALL ALL PIPING AS REQUIRED TO MEET ALL CONSTRUCTION CONDITIONS AND TO ALL FOR INSTALLATION OF OiHER WORK MCLUDING DUCTS AND ELECiRICAL CONDUIT. 11. PROVI�E AN ISOLATING, DIELECTRIC UNION AT ALL CONNECTIONS BETWEEN FERROUS AND NONFERROUS PIPING. 12. PROVIDE ALL FlTiINGS, ACCESSORIES. OFFSETS, AND MAiERIALS NECESSARY TO FACILITATE 7HE PLUMBING SYSTEM'S FUNCTIONING AS IN�ICATED BY THE �ESIGN AN� THE EQUIPMENT INDICATED. 13. FlELD VEPoFY LOCATION OF EXISTING SERVICES TO BE REUSED OR CONNECTED TO AND REPORT TO ARCHITECT/ENGMEER IF OTHER iHAN THAT WHICH IS INDICAiED ON DRAWINGS. 15. COORDINATE ELECTRICAL VOLTAGES WITH ELECTRICAL DRAWINGS PRIOR TO ORDERING ANY EQUIPMENT. i6. COOR�INATE FlXTURE iYPES WI7H THE ARCHITECNRAL �RAWINGS. AREAS �ESIGNAiE� FOR USE BY iHE HANDICAPPED SHALL BE SUPPLIED WITH FIXTURES AND TRIM AS SET FORTH IN THE "AMERICANS" W1TH DISABILITIES ACT"(ADA). 17. WHEN WATER HEAiERS ARE PLACE ABOVE THE CEILING, THE CONTRACTOR SHALL PROVI�E A 1-�" PTRAP WI7H A TRAP PRIMER AT THE NEAREST wASTE OR VENT LINE ABOVE THE CEILING FOR P&T DISCHARGE. 18. WHEN ADDING ON TO OR MAKING AN A�DITION TO AN EXISiING FAQLITY. CONTRACTOR SHALL FlEL� VERIFY EXISiING EQUIPMENT (FIXTURE, TRIM, PUMPS ETC.) MANUFACiURER AND USE SAME MANUFACTURER FOR NEW EQUIPMENT. CONTRACTOR SHALL ATTAIN WRITiEN APPROVAL OF OWNER/OWNER REPRESENTATNE FOR USE OF DIFFERENT MANUFACTURER. 19. ALL PIPING SHALL BE ROUTE� ABOVE CEILING UNLESS OiHER4NSE IN�ICATED. ALL PIPING EXPOSE� TO VIEW SHALL BE ROUTED AS HIGH AS POSSIBLE AND iIGHT TO 7HE UNDERSIDE OF STRUCTURE. 20. ALL WATER PIPING SHALL BE ROUiED ABOVE THE CEILING UNLESS NOTED OTHERWISE. COLD AND HOT WATER PIPING ABOVE GRADE SHALL BE TYPE L HARD DRAWN COPPER TUBING CONFORMING TO ASTM 8-88 WITH SWEAT JOINTS AND COST OR WROUGHT FlTiINGS. JOINTS SHALL BE MAKE WIiH LEAD FREE SOL�ER. WL� WATER PIPING BELOW GRADE SHALL BE TYPE K COPPER NBING WI7H CAST OR WROUGHT FITTINGS AND JOINTS AS DESCRBE� ABOVE. JOINTS SHALL NOT BE PERMIT7ED UNDER FLOOR SLABS. WATER PIPING BELOW GRADE THROUGH CONCRETE SHALL BE PROTECTED WIiH PLASTIC SLEEVES. 2L SANITARY WASiE & VENT, AND STORIA DRAIN PIPING ABOVE GROUND SHALL BE PVC 'MTH SOLVENT JOINTS. 22 SANITARY WASiE & STORM DRAIN PIPWG BELOW GROUND SHALL BE SCHEDULE 40 DWV PVC W1TH SOLVENT JOINTS. 23. SANITARY STACKS SHALL HAVE CLEAN OUTS AT THE BASE OF ALL STACKS. 24 ALL HOT WAiER AND COLD WAiER PIPING ABOVE GRA�E SHALL BE INSULATE� WITH �i" NOMINAL 7HICKNE55 FIBERGLASS PIPE INSULAiION WI7H VAPOR BARRIER JACKET, OWENS-CORNING AS J/SSLII OR EQUAL. 25. WASTE, COLD WAiER AND HOT WATER PIPING AT HANDICAPPED LAVATORIES SHALL BE INSULAiED WITH TRUEBRO "LAV-GUARD" �103. 26. ALL PIPING PENETRATING CEILINGS, WALLS, ANO CASEWORK SHALL BE INSTALLED WITH MATCHING ESCUTCHEONS AT iHE PENETRATION. ALL PIPING PENETRATING EXTERIOR WALLS AND ROOFS SHALL BE FLASHED IN AN APPRWED MANNER AND SHALL BE PROTECTED AS REQUIRED BY THE ARCHITECT 27. TOPS OF ALL FLOOR DRAINS AND CLEANOUTS SHALL BE SET FLUSH WITH FINISHED FLOOR. 28. ROUTE RELIEF VALVE �ISCHAftGE FftOM WATER HEATEft TO NEAREST HUB DRAIN OR TO GRADE OUIDOORS. 29. ROUTE RELIEF VENTS ON ALL BACKFLOW PREVEMERS TO NEAREST FLOOR DRAIN OR CODE APPROVED DRAINAGE RECEPTACLE. 30. SHOP ORAWINGS SHALL BE SUBMITiE� TO AND REVIEWE� BY THE ARCHIIECT PRIOR TO OR�ERING EQUIPMENT OR INSTALLING ANY PIPING PoR ALL EQUIPMENT. FIXTURES, AND PIPING. 31. CONTRACTOR SHALL COORDINATE ELECTRICAL CHARACTERISTICS OF ALL PLUMBING EQUIPMENT WITH iHE ELECTRICAL DRAWINGS. ALL PLUMBING EQUIPMENT REQUIRING ELECTRICAL POWER SHALL BE MSTALLED WITH DISCONNECT SWITCHES AT EACH PIECE OF EQUIPMENT. COOR�INAiE WIiH THE ELECiRICAL CONiRACTOR. 32. WATER PIPING ROUTED ABOVE CBLINGS AND M EXTERIOR WALLS SHALL BE ROUTED ON HEATED SIDE OF CEILING INSULATION AND WALL INSULA710N. 33. ALL PWMBING EQUIPMENT SHALL BE WSTALLED ACCORDING TO MANUFACNRER'S RECOMMENDATIONS. 34. ALL PLUNBING EQUIPMENT AND SYSTEMS SHALL BE GUARANTEED FOR A PERIOD OF ONE YEAR AFTER SUBSiANTIAL COMPLEiION. 35. ANY EXIS7ING WALL, FLOOR, OR CBLING SURFACE THAT IS DISTURBED DURING THE COURSE OF iHE WORK SHALL BE REPAIRED. 36. PRIOR TO PURCHASING ANY MAIERIALS OR STARTING ANY WORK, CONTRACTOR SHALL FIELD VERIFY ALL EXISiING CON�IilONS. PIPING SIZES AND LOCATIONS, E�UIPMENT, ETC. SHOWN ON THE DRAINS OR AFFECTING THIS WORK AN� SHALL REPORT ANY DEVIATIONS TO THE ARCHITECT. U =w �= _�i = = "+ ,. U Y O � ¢� � �/ � �` ���� � w.� S � a tl� e �d 0 o� e � i�;�'r25�° .. r� � �� t� O,R �- • �� � � �� �L �7 � L� U � w 7 O o �a � W 00 o � 0 � � w �J� � �J vsmEeEmmme z Q � Z U � Z � � � z � � � � �me 3/15/20 .n�,^'i: � � 0 � � Q z Q 0 z W J J i � z � N EP- DATE: 06�� $�2O