Loading...
HomeMy WebLinkAboutM003.01MEfA1 flAND OVER INSUUTION (IYPICAL) SPIN-IN CONNECTION E�TERNAl1Y INSUTAIED WITH VOLUME �AMPER PND DPMPER LOCK WI7H E%�ENSION I:l'.7.�[a7dR3i 1�4 W (4" MIN.) W PLL BRANCH CONNECTIONS SHALL BE PRONDED WIiH OPPOSED BIPDE DPMPER PND LOCKING �UPDRaNT. USE YOUNG'S REGUTATOR IF DAMPER IS NOT ACCESIBIE. PPRNLEL BLNE DPMPER SHPLL BE USED IF BRUNCH DUCT HEIGHT INSI�E OIMENSION IS LESS TFNN 9". i/��. -� NR ROW E/A OR R/A � NR ROW S/A ` TRUNK DUCT noh: I. THIS CONNECTION SH4LL BE 7YPICPI FOR ALL RECTANGUUR BRPNCH DUCi CONNEC110N5 TO RECTPNGULW TRUNK DUCTS, INCLUDINC SUPPLY, REfURN, OU�SIDE AIR AND IXHAUST DUCTS. RECTANGULAR BRANCH TAP DETAIL � NO SCALE �CEILINC ` INTEGRAL GRILLE CEILING MOUNTED CABINET 2 EXHAUST FAN DETAIL NO SCALE Low-a6 saiwu oucL xxww zscn EWNOIEM, G4UC£ ffR SMICIN CqI51PL'LIION STNIMP�S o��,µ„� k�-�o �����• �,� HYE WWGER SSIEY. SPq1,ID 8' O.C. Al4YlYVY Fqt SPPoRLL PIPE IMN1£0 IN 10'IENCMS 120-VOLT MOTORRED VOLUNE DAMPER IN OUTSIOE NR DUCT NOTE 4 ACCESSIBLE FILTQi SECPON REFER TO COIL � PIPING DEfAIL NOTE I NOIE 3 � NOIE 2 � fLIX CONNEC710N 5/A DUCT o��T STEEL CHANNEL OR 11NISTRUT � SMOKE DEC S7EEL PNGIE OR UNISTRUT COOftDINATE aECTRicn� PRWIDE AUXILNRY DRAIN PAN BENEA7H FAN COIL UNIT. PROVIDE APRIL NRE REFER TO PLUMBING PUNS FOR PAN SHAl1 BE 3" URGER FILTER $2400 PRIMARI' AND SECONDPHI' DRAIN LINES. TH4N UNIi ON FACH SIDE NOIES: 1. PROVIDE MISCELLANEOUS G4LVPNRED SUPPORT PNGLE OR CHANN0. AS REOUIRED TO BRIDGE STRUCTURE 2. SUSPEND DRAIN PPN WIiH SUPPoRT RODS WHEN AIIACHED TO BUIIDING STRUCNRE. 3. AIIACH TO SiRUCNRE WITH VIBRAPON ISOUTION. 4. INTERLOCK DrVAPER ACNATOR WIiH FAN COIL UNR THQiM05TAT. " FPN ENERGIZED - OPEN DN,IPER " FPN DE-ENERGRED - CLOSED DPMPER 5. G45 PIPING. REF: P3.02 ��AIR HANDLING UNIT MOUNTING ��NO SCALE CORE DRILL WALL FOR CONCREfE CONS7RUC110N OUISI�E -T-INSIOE EQUIPMEM CLENUNCE SEE NOTE 2 1` CWVAFER- GRaDE � � A1IFSIDESRE&4R SUPPoRT FROM SiRUCNRE �AB�JVE WI7H Al1-7HRFA� RODS AND VIBRATION ISO- EQUIPMEN� CLEARANCE SEE NOTE 2 r-----------�� rwu� 1 � , I I I I i i I I � REBeR OR � ��R � WIRE MESH 4' VPRIES � ' � � 6" SPND FlLL 1/2' ASPH4LT 1YPE Fll1ERSI0N JOINT NOTES: 1. SLOPE SUB A MINIMUM OF 1/2"/FOOT BACK TO FROM OR CEMER TO EDGE FOR DRAINAGE. 2. MINIMUM CLFARANCE AROUND E�UIPMEM, ALL SIDES, PER AiANl1FACIDRER. 3. OINENSIONS SHOWN ARE MINIMUM ACCEPTPBLE; REVISE 0.S REQUIRED FOR EOUIPNENT 9EING PROVI�E�. 4. WHERE WAl1 �OES NOT EXIST, INSTAII EQUIPMEM IN CENiER OF PA� AN� ENCLOSE AS SHOWN ON PRCHIiECNRPI DRAWINGS. ���EXTERIOR EQUIPMENT PAD DETAIL ��NO SCALE REFRIGERPNT 110UID 11NE PRON�E 4' SECPON OF WSUlATION AT BLOCKING flASE FOR llOUID LINE MSUTATFD REFRIGERANT SUC110N LINE G4LVPNRED PIPE CNMP (NP.) � PROVIDE WATER-PROOF NON- SHRINK SILICONE SENANT ON PROVIDE CaST IRON WALL PIPE INSIDE AND OU61DE FLUSH WI1H WI7H RETNNMG RING TO ANCHOR W��' PIPE AND ACT AS A WATER STOP. PROVIDE ESCUTCHEON FOR POUR IN PUCE FOR NEW CONCREfE OR IXPOSE� PIPE M FlNISHED IXISTING M45NORY CONSiRUC➢ON SPACE PIPING ARRANGEMEM SHOWN IS SCHEMATIC. PDJUST TO SUR FlELD CONDI110NS. REFER TO SPEQFlCATIONS FOR MORE MFORM4TION ON INSUUTION AND SE4PNT. COORDINAIE SLEEVE INSTPLIAlION WIIH GENERu1 COMRACTOR. PVC SIEE�ES ARE ACCEPTPBLE FOR USE IN ARFAS YA7HOOT REfURN NR PLENUMS. ABOVE GROUND EXTERIOR �a� WALL PENETRATION DETAIL " NO SCALE RELEA5E0 FOR CONSTRIICTI�N Su6jec��o compliance with allregula�ions of S�a�e antl Local Codes City of Carmel r �un��\i lo•rvalM��. DATE: 06�� $�2O PIPE SNDLE (7YP.) 4'x4"x12' LONG MIN. TREATED WOOD BLOCN NOIE: PROVIDE SUPPORTS AT 3'-0' ON CENIERS AND wIIHIN 1'-0" OF ALL CWWGES IN PIPE DIRECiION. REFRIGERANT PIPING ��SUPPORT ON GROUND NO SCALE PRE-MSUTATED FIEXIBLE DUCi AS REOUIRED, INSTP.LL PERMANENRY s�o arvo suPPoarEo TO PREVENT KINKING PND SHARP TURNS - METAL fluND (IYPICAI)- CEILING DIFFUSFR AS SCHEDULEO - CEILING INSUUIED DUCT Nohs: EXIEN� HARD NEfAL DUCT 50 THAT MPXIMOM flEXIBLE DUCT IENGTH DOES NOT E%CEE� 5'-0" PROVI�E RIGI� 90' EIBOW WHERE REQUIRED TO KEEP FIfXIBLE DUCT WITHIN 5'-0' LENGTH LIMITA710N. LAY-IN TYPE 3 CEILING DIFFUSER DETAIL NO SCALE RELOCATE IF SHOWN IN DIFFEREM LOCAlION ON PlANS. INSUlA710N SNFFED UNDER STANDOFF DPMPER ROD INSIDE BFPRING / ii � � �� � SECUR0.Y � ii � AIIACH ROD TO ' I DPMPER BUDE � ii / ELEVAIED REGUTATOR DURO DYNE MODEL SRTS 2 OR PPPRO�ED EQUPL STAINlESS STEEL CIAAIP STNNlFSS 51E0. � ��P 3/8"0 ROD WIiH y" INSUUTION WI1H NNYL NriON BEPRING VAPoR &4RRIER U.L 181 CUSS NINIMUM 26 GAUCE 1 REXIBLE DUCT NOIE: 1. NPICAL OF All ACCESSIBLE ROUND DUCT CONNEC110NS TO RECTANGUTAR DUCi. �� SPIN-IN CONNECTION NO SCALE Angle the burner suspension chain back over the burner to� allow system expansion � , _ '�..�. The distance behveen the _ tube flange and face of � the plate hanger must be 4.5" (11.4 cmj 11 HEATER DETAIL NO SCALE ti� Luiti� � 11uNw1 �Edifica � case engineenng ��� �� �, fia ,� s i ion_ize �c��-,i rrrm.ioo �i��n�e �<rii��.i,_o i� -�.�o�..u,�- ,N. ti°i cai<imicnn.:o nuiuoi<rrv. .._ .,.. �i . M4NUP1 VOWME DAMPER IN REfURN NR DUCT CDIING qfNSER SF£ SCIEDUI£ FOP � uooe� t. LONG RPDIUS COPPER LOOP SUC110N PIPING EIBOW (1YPICPL) TO TOP OF DX COIL LINTI� DRYER THERAIAL E YPASS SIGFR yq�yE (7Ey � �IA55 r i. AIR COOLE� CONDENSING UNR GROUND \ SHUT-OFF �A�� �,����� RNNERI � �APORATOR COIL UNION (iYPIGQ REFRIGERANT TRAP REFRIGERPNT SUCTION 11NE REFRIGERPNT IIQUID IINE NpTES: I. SUC110N LWE TRW TO BE E%IENDED ABOVE EVAPoRPTOR COIL 2. COMRPCTOR TO VERIFY PIPE S2ES REQI11RE0 WIIH EQUIPMENT SUPPLIER. 3. PITCH SUCTION LINE TOWARDS CONDENSING UNR. 4. SIGHT GVSS TO BE FULL IINE SRE AND INSTALLED IN 1HE MFIN 114UID IINE. 5. LOCATE TEV BULB 45' ABOVE BOIIOAI OF PIPE. REFRIGERANT PIPING DETAIL WITH COIL ABOVE CU (SINGLE CIRCUIT� 4 �� ^ ervo w� m. *o cou�c Lf2fER N IRCHIIECNRLL UMGS fOR courc ttrc ���DUCT SUPPORT DETAIL ��NO SCALE RIGID DUCT INSTALLATION VO JOISf OP O1HER SUPPoIif M NINMUA SIPI➢, I' WOE. 6' OMIM HOPoZOMIL SPACINC nr rw o� oucr UAOfR WCT I' Y.1iN j8 10 " 1. BurnerAssembly 2. Flange Adapter 3. Flangetl Tube 4. Swaged Tube 5. venttermination (optional: wall or roof) 6. End Plate Hanger 7. Webbed Hanger 8. Hanging Chains 9. Focus Shield Reflector 10, Refledor Stabilizer � �� C 0 R T L A N D M 0 R fi A X ARCHITECT 711 N. FIELDER RD. ARLINGTON, TX 76012 PH: (817) 635-Sfi96 FA%: (817) 635-5699 � Vl 0 �+ -� z � o `� +� �oa q � • rl I q � �1 O O h�p U J rl �.y � m � M O � O �;0��" ��jz� +j ��ox � � �1 .� A O � �� \ � U `/ � a T-� d � � � � m��� f� p V �� �� U ~ [19100I62 s rai c or Date Revisions 5/10/19 - Issuetl for CBA Review 5l1]119- Issuetl for Builtling Permit Submittal 6/19/19 - Revision 1- Per Sewer Permi[ Camments 8 Owner Project No. 19-01 Drawn By: STAFF Date: 5/17/19 MECHANICAL DETAILS -3.01 9LHN-04-2019 TYPICAL HANGER & SUPPORT SPACING