HomeMy WebLinkAboutA100.6_R1UNDISTURBED SOIL
8"T X 16" W CAST-IN-PLACE CONCRETE FOOTING
4" PERFORATED PERIMETER DRAIN
8" CMU FOUNDATION WALL
2" FOAM INSULATION
6 MIL VAPOR BARRIER
4"T PEA GRAVEL
2X10 FLOOR JOISTS @ 16 O/C
3/4" TONGUE & GROOVE OSB SUBFLOOR
1/2" ANCHOR BOLT @ 72" O/C
FINISH GRADE (VARIES, NO LESS THAN 4"
FROM TOP OF CMU FOUNDATION)
TREATED 2X4 SILL PLATE
2X10 RIM JOIST
1/2" ZIP SYSTEM (OR EQUIV.) WALL SHEATHING
STONE VENEER TO MATCH EXISTING
2X4 BOTTOM PLATE
2X4 WALL STUDS @ 16" O/C
R-15 KRAFT-FACED BATT INSULATION
STONE SILL TO MATCH EXISTING
DOUBLE 2X4 ROUGH SILL
1X4 R/S CEDAR BAND BOARD, PAINTED
FRAMED WINDOW OPENING
1/2" DRYWALL, FINISHED, PRIMED, & PAINTED
1/2" DRYWALL CEILING, TEXTURED, PRIMED, &
PAINTED
R-38 KRAFT-FACED BATT INSULATION
2X10 CEILING JOISTS @ 16" O/C
DOUBLE 2X8 HEADER
DOUBLE 2X4 TOP PLATE
1X8 R/S CEDAR FRIEZE BOARD WITH MOLDING TO
MATCH EXISTING, PAINTED
3/8" R/S FIR PLYWOOD WITH ALUMINUM VENTS, PAINTED
1X6 R/S CEDAR FASCIA, PAINTED
6" ALUMINUM GUTTER, WHITE
2X SUBFASCIA TO MATCH EXISTING
ALUMINUM GUTTER APRON, WHITE
SIMPSON STRONG-TIE (OR EQUIV.) RAFTER STRAPS
2X6 RAFTERS @ 16" O/C
14"W RAFTER INSULATION BAFFLE VENT
7/16" OSB ROOF SHEATHING
SYNTHETIC UNDERLAYMENT
3-TAB SHINGLES TO MATCH EXISTING
ICE & WATER SHIELD
FIBER CEMENT SIDING, PAINTED
0' 0"
TOP OF EXISTING SUBFLOOR
- 1' 0"
TOP OF NEW SUBFLOOR
TT- 1' 11 1/2"
TOP OF CMU
- 5' 3 1/2"
TOP OF CMU
APPROX. + 8' 1"
(MATCH EXISTING TOP
PLATE HEIGHT)
TOP OF NEW WALL
PERMIT
#0
ISSUE DATE:
2020-06-03
REV:
www.caseindy.com
99 E. Carmel Drive, Suite 100
Carmel, Indiana 46032
317.846.2600 317.846.2601(f)
These drawings have been prepared by Case
Design & Remodeling solely for its use and
should not be reproduced or relied upon by any
other parties. Dimensions shown or scaled are
subject to change per actual job condition and
must be verified. Materials are to be supplied as
specified as equal or standard when not
uniquely specified. Installed materials may vary
in appearance from drawings. Reference
manufacturer's product data for actual
appearance and specifications.BRICKER - SUTTON PROJECTROOM ADDITIONJON BRICKER & SUE SUTTON10923 BRAEWICK DRIVECARMEL, INDIANA 46033Approved By:
Date:
A601
Craig Dice
Architectural Designer
cdice@caseindy.com
David Null
Project Developer
dnull@caseindy.com
242590141
JOB NUMBER:
TYPICAL WALL SECTIONA
A601
A
A601 SCALE: 3/4" = 1'-0"
#1 2020-06-17
R1R1
06/24/20
Adam Schriner