HomeMy WebLinkAboutE100.0_R1EP
R R
R R
WP
3DM
3DM
3DM3DM
R R
RR
R
R R
RR
RR
R R
C5E
TV
TV
DM
SD
SD
SD
SD
SD
CO
MASTER BEDROOM
MASTER BATH
MASTER CLOSET
BEDROOM #2
BEDROOM #3BEDROOM #4
WALK-IN
CLOSET
CLO. #2
CLO.
#3
CLO.
#4
HALL #1
CLO.
#1
FOYER
COAT
CLO.
LIVING ROOM
NEW OFFICE
FAMILY ROOM
KITCHEN STAIRS
TO
BSMT
HALL #2
BATH #2
LAUNDRY ROOM
GARAGE
CLOSET #5
BATH #1
NEW DINING ROOM
INSTALL HOMEOWNER-PROVIDED WALL-MOUNTED EXTERIOR
LIGHT FIXTURE ON NEW SINGLE-POLE SWITCH
INSTALL HOMEOWNER-PROVIDED CEILING-MOUNTED PENDANT
LIGHT FIXTURE ON NEW SINGLE-POLE DIMMER SWITCH
FURNISH & INSTALL (4) NEW 6" LED RECESSED CAN LIGHTS ON
NEW 3-WAY DIMMER SWITCH
FURNISH & INSTALL (1) NEW GFCI 15A 102V RECEPTACLE IN
WEATHERPROOF HOUSING
FURNISH & INSTALL (7) NEW 15A 120V RECEPTACLES IN NEW
DINING ROOM AS SHOWN
FURNISH & INSTALL (4) NEW 6" LED RECESSED CAN LIGHTS ON NEW
SINGLE-POLE DIMMER SWITCH (EXISTING SINGLE-POLE SWITCH AT
NEW SWITCH LOCATION CONTROLS HALF-HOT RECEPTACLE)
RELOCATE (1) EXISTING 6" RECESSED CAN LIGHT IN EXISTING LIVING
ROOM (VERIFY NEW LOCATION WITH HOMEOWNER PRIOR TO
ROUGH-IN)
FURNISH & INSTALL (1) NEW COAXIAL CABLE TV JACK (VERIFY
LOCATIONS WITH HOMEOWNER PRIOR TO ROUGH-IN)
FURNISH & INSTALL NEW SINGLE-POLE SWITCH INSIDE NEW OFFICE
FOR EXISTING RECESSED CAN LIGHTS
FURNISH & INSTALL NEW CAT5E WIRING & JACK IN NEW OFFICE
(VERIFY LOCATION WITH HOMEOWNER PRIOR TO ROUGH-IN)
FURNISH & INSTALL (1) NEW COAXIAL CABLE TV JACK (VERIFY
LOCATIONS WITH HOMEOWNER PRIOR TO ROUGH-IN)
EXISTING HARD-WIRED SMOKE
DETECTOR OUTSIDE OF SLEEPING
AREA
FURNISH & INSTALL NEW CEILING-
MOUNTED INTERCONNECTED
SMOKE DETECTOR IN EACH
BEDROOM (TYP. EACH BEDROOM
AS SHOWN)
FURNISH & INSTALL NEW HARD-
WIRED CARBON MONOXIDE
DETECTOR OUTSIDE OF SLEEPING
AREA
NPERMIT
#0
ISSUE DATE:
2020-06-03
REV:
www.caseindy.com
99 E. Carmel Drive, Suite 100
Carmel, Indiana 46032
317.846.2600 317.846.2601(f)
These drawings have been prepared by Case
Design & Remodeling solely for its use and
should not be reproduced or relied upon by any
other parties. Dimensions shown or scaled are
subject to change per actual job condition and
must be verified. Materials are to be supplied as
specified as equal or standard when not
uniquely specified. Installed materials may vary
in appearance from drawings. Reference
manufacturer's product data for actual
appearance and specifications.BRICKER - SUTTON PROJECTROOM ADDITIONJON BRICKER & SUE SUTTON10923 BRAEWICK DRIVECARMEL, INDIANA 46033Approved By:
Date:
E101
Craig Dice
Architectural Designer
cdice@caseindy.com
David Null
Project Developer
dnull@caseindy.com
242590141
JOB NUMBER:
FIRST FLOOR PROPOSED ELECTRICAL PLANA
E101
A
E101 SCALE: 1/4" = 1'-0"
#1 2020-06-17
R1R1
06/24/20
Adam Schriner