1 NORTH ELEVATION ° 8'
SCALE: 1 /4" = V-0" 4
rJ
L
1 SOUTH ELEVATION ° 8' 16'
4C'Al P 114" = v_m
I I
L- — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — —
2 EAST ELEVATION ° 8' 16'
SCALE: 1 /4" = V-0" 4
1 1 11 1 1 1 1 1
1 1 1 1 1 1 L
r I I I I I I I �
I �� L_� L_� ��
L- — — — — — — — — — — — — — — — — — — — J — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — —
9 4 9 9 9
4 WEST ELEVATION 8
SCALE: 1 /4" = V-0"
OVERHEAD DOOR
AND TRACK
M ETA L
BUILDING
SYSTEM
EDGE OF SLAB
BOLLARD — SEE
CIVIL DRAWINGS,
PAINT SAFETY
YELLOW
) O R JAMB
THRU ROOF PIPE — SEE
PLUMBING DRAWINGS
PRIOR TO SLIDING DEKTITE
DOWN OVER PIPE, PLACE
A CONTINUOUS BEAD OF
APPROVED SEALANT
AROUND PIPE AT THE
HEIGHT OF THE BOOT SO
THAT WHEN THE BOOT IS
IN PLACE THE TOP OF
THE BOOT ENGAGES THE
SEALANT
DEKTITE PIPE FLASH; CUT
TO PIPE SIZE IN FIELD SO
THAT FLASHING FITS
*SNUGGLY AROUND PIPE;
SET BASE IN CONTINUOUS
BEAD OF APPROVED
SEALANT
3/16" BULB—TITE BLIND
RIVETS W/ SEALING
WASHERS @ 2" O.C.
ROOF PANEL
7 VENT DETAIL AT ROOF PANEL
SCALE: NTS
NEW WORK KEY NOTES "o "
1. CENTER LINE (TYPICAL) DEPICTS METAL BUILDING STRUCTURAL
SYSTEM -SEE METAL BUILDING DOCUMENTATION.
2. INTAKE LOUVER — SEE MECHANICAL DRAWINGS.
3. STRUCTURAL SUPPORT FOR MECHANICAL EQUIPMENT SHALL BE
DESIGNED BY METAL BUILDING ENGINEER, SEE METAL BUILDING
DOCUMENTATION. METAL BUILDING ENGINEER SHALL COORDINATE AND
VERIFY OPENING SIZE AND WEIGHT WITH MECHANICAL EQUIPMENT.
INSTALL METAL BUILDING MANUFACTURER HEAD, JAMB AND SILL TRIM
FLASHING AND SEALANT ALL AROUND TO PROVIDE A WATERTIGHT
INSTALLATION..
4. FOOTING, FOUNDATIONS AND SLAB — SEE STRUCTURAL DRAWINGS.
5. RESTROOM EXHAUST FAN — SEE MECHANICAL DRAWINGS.
6. EXHAUST FAN — SEE MECHANICAL DRAWINGS.
7. PERSONNEL DOOR — SEE METAL BUILDING DOCUMENTATION.
8. VEHICLE EXHAUST SYSTEM — SEE MECHANICAL DRAWINGS.
9. BOLLARDS — SEE DETAIL 6/A50002 AND CIVIL DRAWINGS.
10. LIGHT — SEE ELECTRICAL DRAWINGS.
11. OVERHEAD DOOR — DOOR AND OPERATOR SUPPORTS SHALL BE
DESIGNED BY OVERHEAD DOOR MANUFACTURER AND SHALL BE
COORDINATED WITH METAL BUILDING STRUCTURAL SYSTEM. THE DOOR
TRACK AND DOOR SHALL BE INSTALLED DIRECTLY UNDER ROOF
STRUCTURE AND FOLLOW THE ROOF SLOPE TO ALLOW MAXIMUM
CLEARANCE BELOW.
DOOR SHALL BE 2" THICK INSULATED PANELS, 12"X24" INSULATED
1" TEMPERED GLASS.
12. VEHICLE LIFT.
GENERAL NOTES
A. SEE METAL BUILDING DOCUMENTATION FOR DESIGN OF THE
METAL BUILDING SYSTEM.
B. SEE ELECTRIC, MECHANICAL, AND CIVIL DRAWINGS FOR