Loading...
HomeMy WebLinkAboutElevations-A50002O N O Z O O C) O ry n 0 O O E 0 0 / N 00 00 0 P O u � I �m D~ D N Do N n Z s / 0 0 �u 0 F � o �u x / DI Dw ,ry -X L �- O r7 �Lo D 0 N O N J I � N � I J O I I L— — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — J 1 NORTH ELEVATION ° 8' SCALE: 1 /4" = V-0" 4 rJ L 1 SOUTH ELEVATION ° 8' 16' 4C'Al P 114" = v_m I I L- — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — 2 EAST ELEVATION ° 8' 16' SCALE: 1 /4" = V-0" 4 1 1 11 1 1 1 1 1 1 1 1 1 1 1 L r I I I I I I I � I �� L_� L_� �� L- — — — — — — — — — — — — — — — — — — — J — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — 9 4 9 9 9 4 WEST ELEVATION 8 SCALE: 1 /4" = V-0" OVERHEAD DOOR AND TRACK M ETA L BUILDING SYSTEM EDGE OF SLAB BOLLARD — SEE CIVIL DRAWINGS, PAINT SAFETY YELLOW ) O R JAMB THRU ROOF PIPE — SEE PLUMBING DRAWINGS PRIOR TO SLIDING DEKTITE DOWN OVER PIPE, PLACE A CONTINUOUS BEAD OF APPROVED SEALANT AROUND PIPE AT THE HEIGHT OF THE BOOT SO THAT WHEN THE BOOT IS IN PLACE THE TOP OF THE BOOT ENGAGES THE SEALANT DEKTITE PIPE FLASH; CUT TO PIPE SIZE IN FIELD SO THAT FLASHING FITS *SNUGGLY AROUND PIPE; SET BASE IN CONTINUOUS BEAD OF APPROVED SEALANT 3/16" BULB—TITE BLIND RIVETS W/ SEALING WASHERS @ 2" O.C. ROOF PANEL 7 VENT DETAIL AT ROOF PANEL SCALE: NTS NEW WORK KEY NOTES "o " 1. CENTER LINE (TYPICAL) DEPICTS METAL BUILDING STRUCTURAL SYSTEM -SEE METAL BUILDING DOCUMENTATION. 2. INTAKE LOUVER — SEE MECHANICAL DRAWINGS. 3. STRUCTURAL SUPPORT FOR MECHANICAL EQUIPMENT SHALL BE DESIGNED BY METAL BUILDING ENGINEER, SEE METAL BUILDING DOCUMENTATION. METAL BUILDING ENGINEER SHALL COORDINATE AND VERIFY OPENING SIZE AND WEIGHT WITH MECHANICAL EQUIPMENT. INSTALL METAL BUILDING MANUFACTURER HEAD, JAMB AND SILL TRIM FLASHING AND SEALANT ALL AROUND TO PROVIDE A WATERTIGHT INSTALLATION.. 4. FOOTING, FOUNDATIONS AND SLAB — SEE STRUCTURAL DRAWINGS. 5. RESTROOM EXHAUST FAN — SEE MECHANICAL DRAWINGS. 6. EXHAUST FAN — SEE MECHANICAL DRAWINGS. 7. PERSONNEL DOOR — SEE METAL BUILDING DOCUMENTATION. 8. VEHICLE EXHAUST SYSTEM — SEE MECHANICAL DRAWINGS. 9. BOLLARDS — SEE DETAIL 6/A50002 AND CIVIL DRAWINGS. 10. LIGHT — SEE ELECTRICAL DRAWINGS. 11. OVERHEAD DOOR — DOOR AND OPERATOR SUPPORTS SHALL BE DESIGNED BY OVERHEAD DOOR MANUFACTURER AND SHALL BE COORDINATED WITH METAL BUILDING STRUCTURAL SYSTEM. THE DOOR TRACK AND DOOR SHALL BE INSTALLED DIRECTLY UNDER ROOF STRUCTURE AND FOLLOW THE ROOF SLOPE TO ALLOW MAXIMUM CLEARANCE BELOW. DOOR SHALL BE 2" THICK INSULATED PANELS, 12"X24" INSULATED 1" TEMPERED GLASS. 12. VEHICLE LIFT. GENERAL NOTES A. SEE METAL BUILDING DOCUMENTATION FOR DESIGN OF THE METAL BUILDING SYSTEM. B. SEE ELECTRIC, MECHANICAL, AND CIVIL DRAWINGS FOR ADDITIONAL INFORMATION.