Loading...
HomeMy WebLinkAboutGeneral Notes-A00001s� D I Do � I tm �N �0 > 'o N n z >C �0 0 �U �C i O 5 �o X 0 N 0 N I G) N I 0 0 ARCHITECTURAL ABBREVIATIONS MATERIAL INDICATIONS ARCHITECTURAL GENERAL NOTES @ AT JAN JANITOR 1. GENERAL NOTES LISTED ON THIS SHEET AND ALL OTHER SHEETS SHALL APPLY TO THE A/C AIR CONDITIONER JT JOINT PROJECT AS A WHOLE. ACOUST ACOUSTICAL L LENGTH 2. PROTECT ALL EXISTING UTILITIES DURING COURSE OF THE WORK. WHERE UTILITY SERVICES ACT ACOUSTICAL CEILING TILE LAM LAMINATE ARE REQUIRED TO BE REMOVED, RELOCATED, OR MODIFIED, PROVIDE BYPASS CONNECTIONS AD ACCESS DOOR LAV LAVATORY TO MAINTAIN CONTINUITY OF SERVICE TO OTHER PARTS OF THE BUILDING BEFORE ADJ ADJACENT, ADJUSTABLE LB(S) POUND, POUNDS PROCEEDING WITH THE WORK. AFF AGG ABOVE FINISHED FLOOR AGGREGATE LTWT CONC MATL LIGHTWEIGHT CONCRETE MATERIAL EARTH �� �� EARTH o�°o.o °g ����og �� ° GRANULAR FILL :. r... SAND 3. MAINTAIN ALL UTILITY SERVICE AND PROTECT EQUIPMENT AGAINST DAMAGE DURING CONSTRUCTION. DO NOT INTERRUPT EXISTING UTILITIES SERVING OCCUPIED OR OPERATING MAX MAXIMUM �0o 8°0� ALUM ALUMINUM o°0 FACILITIES, EXCEPT WHEN AUTHORIZED IN WRITING BY THE BUILDING MANAGER AND ANCH ANCHOR, ANCHORAGE MECH MECHANICAL AUTHORITIES HAVING JURISDICTION. IF REQUIRED BY THE OWNER, AT THE CONTRACTORS ANOD ANODIZED MED MEDIUM EXPENSE, PROVIDE TEMPORARY SERVICE DURING INTERRUPTIONS TO EXISTING UTILITIES. APP'D APPROVED MANUF MANUFACTURER PROVIDE NOT LESS THAN 10 WORKING DAYS PRIOR NOTICE TO THE OWNER AND BUILDING ARCH ASSOC ARCHITECTURAL ASSOCIATED MIN MISC MINIMUM MISCELLANEOUS STEEL OR MANAGER IF SHUTDOWN OF SERVICE IS REQUIRED. AUTO AUTOMATIC METALS ALUMINUM 4. STRUCTURAL MEMBERS SHALL NOT BE CUT OR ALTERED, EXCEPT WHERE NOTED ON AUX AUXILIARY MO MASONRY OPENING STAINLESS STEEL DRAWINGS, WITHOUT AUTHORIZATION OF THE OWNER. WORK REMAINING IN PLACE WHICH IS AVG AVERAGE MTD MOUNTED DAMAGED OR DEFACED DURING THE CONTRACT SHALL BE RESTORED TO THE CONDITION BID D BOARD MTG HT MOUNTING HEIGHT EXISTING AT TIME OF AWARD OF CONTRACT. BUILDING MTL METAL 5. CONSTRUCTION SHALL BE IN ACCORDANCE WITH U.L. LISTED RATED WALL ASSEMBLIES. BLK BLOCK N/A NOT APPLICABLE 6. UNLESS OTHERWISE NOTED ON DRAWINGS OR SPECIFIED, NEW WORK IN EXTENSION OF BOT BOTTOM NEC NIC NECESSARY NOT IN CONTRACT MASONRY COMMON OR CONCRETE CUT STONE EXISTING CONDITIONS SHALL CORRESPOND IN ALL RESPECTS WITH THAT TO WHICH IT BSMT BASEMENT NTS NOT TO SCALE FACE BRICK MASONRY UNIT CONNECTS OR TO SIMILAR EXISTING CONDITIONS, IN MATERIALS, WORKMANSHIP AND FINISH. BUR BUILT UP ROOFING NO,# NUMBER 7. ALL MATERIALS, INSTALLATION, AND WORKMANSHIP SHALL COMPLY WITH ALL APPLICABLE CABT CABINET NOM NOMINAL STATE AND CITY CODES AND ORDINANCES, INDUSTRY STANDARDS, UTILITY COMPANY CEM CEMENT OC ON CENTER REGULATIONS AND ALL REQUIREMENTS OF LOCAL AND FEDERAL AUTHORITIES HAVING CER CERAMIC OD OUTSIDE DIAMETER JURISDICTION. MORE STRINGENT GUIDELINES FOR INSTALLATION AS ESTABLISHED BY THE CHK'D CHECKED OH OVERHEAD �; �— OWNER, PRODUCT MANUFACTURER, OR THE RELEVANT STANDARDS ORGANIZATION SHALL BE CJ CONTROL JOINT OPENG OPENING CONCRETE . ��::e:� '�. •' CONCRETE " ` TERRAllO STRICTLY FOLLOWED WITHOUT ADDITIONAL COST TO THE OWNER. CL CENTER LINE OPP OPPOSITE 8. CONTRACTORS SHALL BE RESPONSIBLE FOR ADHERING TO ALL AT&T REQUIREMENTS AND CLG CEILING PART PAR PARTITION GUIDES GOVERNING WORK PERFORMED IN OCCUPIED SWITCH/OFFICE SPACES. ALL ISSUES CLR CLEAR PL PLATE SHALL BE COORDINATED WITH AT&T PROJECT MANAGER. CLOS CLOSET PL LAM PLASTIC LAMINATE 9. CONTRACTOR SHALL COORDINATE ALL DEMOLITION WORK AND NEW CONSTRUCTION WORK CMU CONCRETE MASONRY UNIT PLMBG PLUMBING WITH PROJECT MANAGER AND BUILDING MANAGER TO MINIMIZE BUSINESS DISRUPTIONS WHILE COL COLUMN PLAS PLASTER WOOD FINISHED ROUGH PLYWOOD NEW CONSTRUCTION IS IN PROGRESS. CONC CONCRETE PLYWD PLYWOOD WOOD WOOD 10. PROVIDE PORTABLE FIRE EXTINGUISHERS DURING CONSTRUCTION OF BUILDING AS REQUIRED CONT CONTINUOUS PR PAIR BY LOCAL CODES AND FIRE DEPARTMENT. FIRE EXTINGUISHERS MUST BEAR THE LABEL OF CONTR CONTRACTOR PREFAB PREFABRICATED AN APPROVED AGENCY. NO DRY CHEMICAL EXTINGUISHERS ARE TO BE PLACED OR USED IN COORD COORDINATE PROV PROVIDE TELECOMMUNICATIONS EQUIPMENT AREAS. CPT CARPET PSF POUNDS PER SQUARE FOOT 11. CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS AND REPORT ANY DISCREPANCIES TO CT CERAMIC TILE PSI POUNDS PER SQUARE INCH GYPSUM RIGID BATT THE AT&T PROJECT MANAGER AND OWNER'S CONSTRUCTION REP. CTR CVB CENTER COVED VINYL BASE PT PVC PAINT, POINT POLYVINYL CHLORIDE MISC. • ' : BOARD INSULATION INSULATION 12. CONTRACTORS ARE TO CONFINE CONSTRUCTION TRAFFIC AND DEBRIS REMOVAL TO THE CYL CYLINDER CONSTRUCTION AREA AS MUCH AS POSSIBLE TO MINIMIZE DUST MIGRATION. ERECT DUST D DEEP (DEPTH) QT R QUARRY TILE RADIUS, RISER PARTITIONS WHERE DEMOLITION AND/OR NEW CONSTRUCTION ABUTS EXISTING FINISHED DBL DOUBLE RB RUBBER BASE SPACES. SEE DUST PROTECTION SHEET DEMO DEMOLITION RD ROOF DRAIN 13. CONTRACTOR SHALL COORDINATE STORAGE OF BUILDING MATERIALS AND THE REMOVAL AND DEP DEPRESSION, DEPRESS REF REFLECTEDREFERENCEREFER , , ACOUSTICAL ° �° CLEAN—UP OF ALL DEBRIS CAUSED BY HIS WORK DURING CONSTRUCTION. CLEAN ALL "AS DET DETAIL REINF REINFORCEMENT MISC. MEMBRANE TILE e° PAVING AREAS TO IS" CONDITIONS AT THE END OF EACH WORK DAY. DF DRINKING FOUNTAIN RELOC RELOCATE, RELOCATED 14. SEE MECHANICAL, FIRE PROTECTION AND ELECTRICAL DRAWINGS, ETC., FOR ADDITIONAL DIA DIAMETER REPL REPLACE WORK TO BE COORDINATED WITH THIS PROJECT AND THE REQUIREMENTS SPECIFIED HEREIN. DIM DIMENSION REQ REQUIRE, REQUIRED 15. DIMENSIONS INDICATED ON PLANS ARE FROM FACE MATERIAL, I.E. FACE OF GYPSUM BOARD, DN DOWN REV REVISE, REVISION CONCRETE BLOCK ETC. DR DOOR ROOFG ROOFING 16. ROOM NUMBERS ARE SHOWN FOR REFERENCE AND CONSTRUCTION PURPOSES FOR THIS PROJECT NAME: DWG(S) DRAWINGS) RH RIGHT HAND PROJECT ONLY. DWL DOWEL RO ROUGH OPENING EA EACH RM ROOM EL ELEVATION SCWD SOLID CORE WOOD ELECT ELECTRICAL SCHED SCHEDULE ELEV ELEVATOR SEAL SEALANT 96TH STREET GARAGE ENCLOS ENCLOSURE SHT SHEET MAINTENANCE BUILDING GRAPHIC SYMBOLS EQ EQUAL SIM SIMILAR EQUIP EQUIPMENT SPEC(S) SPECIFICATION AND SITE WORK EXH EXHAUST SQ SQUARE EXIST EXISTING SS STAINLESS STEEL EXP EXPANSION, EXPOSED STD STANDARD EJ EXPANSION JOINT STL STEEL EXIST EXISTING STRUC STRUCTURAL (STRUCTURE) COL-00255676-A1 EXT EXTERIOR SUSP SUSPEND, SUSPENDED FD FLOOR DRAIN SVB STRAIGHT VINYL BASE CONSULTANT STAMP FDN FOUNDATION T TOP, THICK FIN FINISH T&B TOP AND BOTTOM Exp A/E, Inc. FLR FLOOR T&G TONGUE & GROOVE t: +1.614.744.4300 I f: +1.614.744.4350 e® FLEX FLEXIBLE TEMP 150 E. Gay Street =® m FRP FIBERGLASS REINFORCED TERR TERRAllO Suite 1510 FT(') FEET (FOOT) THK THICK, THICKNESS bus, OH 43215 x r) FTG FURN FOOTING FURNISH, FURNITURE THRU TS THROUGH A COLUMN CENTER —LINES SPOT ELEVATION— EXISTING ELEVATION TARGET U.S.A. A r • www.exp.com GA GAUGE TYP TYPICAL GALV GALVANIZED UL UNDERWRITERS LABORATORIES O TOP OF STEEL ITEM BEING REFERENCED GC GENERAL CONTRACTOR UNO UNLESS NOTED OTHERWISE �o GEN GENERAL VAT VINYL ASBESTOS TILE + +20I-o" DATUM ELEVATION N•BUILDINGS •EARTH &ENVIROMENT •ENERGY• GL GLASS, GLAZING VB VINYL BASE GRID LINE NUMBER GYP. BD. GYPSUM BOARD VCT VINYL COMPOSITION TILE • • INDUSTRIAL INFRASTRUCTURE • SUSTAINABILITY • H HIGH VERT VERTICAL HCWD HDW HOLLOW ORE WOOD HARDWARE C W VINYL WALL COVERING WATERCLOSET CENTER LINE SPOT ELEVATION— NEW PARTITION TARGET REVISIONS / AUTHORIZATIONS HM HOLLOW METAL WT WEIGHT HORIZ HP HT(H) HORIZONTAL HIGH POINT HEIGHT WWF W W/ WELDED WIRE FABRIC WIDTH, WIDE WITH PARTIAL SECTION NIx a PARTITION TYPE NUMBER NO. REVISIONS / AUTHORIZATIONS DATE BY HVAC HEATING VENTILATING AIR—CONDITIONING W/0 PERMIT ISSUE 06/26/20 M B � WWITHINITHOUT WOOD + INFO INFORMATION Wp WORKING POINT 1 SECTION NUMBER BULLETIN 1 06/19/20 M B INSUL INT INSULATE, INSULATION INTERIOR Al � SHEET NUMBER DOOR TARGET ADDENDUM A 06/09/20 MB WINDOW TARGET I NEW DOOR 8c NUMBER BID ISSUE 05/14/20 M B DETAIL REFERENCE 4 WINDOW TYPE CD ISSUE 2 05/07/20 MB EXISTING DOOR CID ISSUE 04/30/20 M B 2 � DETAIL NUMBER ROOM NAME /NUMBER DID ISSUE 04/09/2 MMB A2 SHEET NUMBER -- EXTERIOR ELEVATION OFFICE ROOM NAME PROPRIETARY AT&T INFORMATION NOT FOR GENERAL USE OR DISCLOSURE OUTSIDE OF AT&T 101 ROOM NUMBER Q ELEVATION NUMBER THIS INFORMATION MAY ONLY BE USED BY AUTHORIZED A6 PERSONNEL OF THE LOCAL GOVERNMENT AGENCY IN CONNECTION SHEET NUMBER WITH APPLICATION FOR PERMITS AND AUTHORIZATIONS FOR DRAWING NUMBER, TITLE, SCALE BUILDINGS, CONSTRUCTION, AND/ OR ZONING CHANGES. BUILDING SECTION GROUND FLOOR PLAN INTERIOR ELEVATION DRAWINGS PREPARED FOR 3 SECTION NUMBER 1 � = 1,_0� /$ 1 SHEET NUMBER � CORPORATE A3 � SHEET NUMBER 4 A5 2 � ELEVATION NUMBER _= �- REAL ESTATE NORTH ARROW KEY NOTE 3 PROJECT DRAWING MATCH LINE O O REVISION TARGET A2.1 CURRENT SHEET NUMBER A2.2 ADJACENT AREA 4160 E. 96TH STREET � AREA OF REVISION SHEET NUMBERc::: INDIANAPOLIS north IN US DEMOLITION WORK 1 REVISION NUMBER LIMITS OF CONSTRUCTION CRMLIN02 116427.01 N26102 — — WALLS TO BE SHEET TITLE: — — REMOVED DIMENSIONING CONVENTIONS GENERAL NOTES ARCHITECTURAL DOORS TO BE 2' —0" AT&T PROJECT NUMBER: DATE: — — — SCALE: — / REMOVED -- M 2 8 3 0 4 DRAWN BY: — — — CHECKED BY: --- AT&T AUTHORIZATION: SHEET: — OF: — SHEETS SHEET NO. AT&T DRAWING NO.: AT&T PM: NIGEL DOWNTON M28304A00001 A00001