HomeMy WebLinkAboutGeneral Notes-A00001s�
D I
Do
� I
tm
�N
�0
> 'o
N
n z
>C
�0
0
�U
�C
i O
5
�o
X
0
N
0
N
I
G)
N
I
0
0
ARCHITECTURAL
ABBREVIATIONS
MATERIAL INDICATIONS
ARCHITECTURAL GENERAL NOTES
@
AT
JAN
JANITOR
1.
GENERAL NOTES LISTED ON THIS SHEET AND ALL OTHER SHEETS SHALL APPLY TO THE
A/C
AIR CONDITIONER
JT
JOINT
PROJECT AS A WHOLE.
ACOUST
ACOUSTICAL
L
LENGTH
2.
PROTECT ALL EXISTING UTILITIES DURING COURSE OF THE WORK. WHERE UTILITY SERVICES
ACT
ACOUSTICAL CEILING TILE
LAM
LAMINATE
ARE REQUIRED TO BE REMOVED, RELOCATED, OR MODIFIED, PROVIDE BYPASS CONNECTIONS
AD
ACCESS DOOR
LAV
LAVATORY
TO MAINTAIN CONTINUITY OF SERVICE TO OTHER PARTS OF THE BUILDING BEFORE
ADJ
ADJACENT, ADJUSTABLE
LB(S)
POUND, POUNDS
PROCEEDING WITH THE WORK.
AFF
AGG
ABOVE FINISHED FLOOR
AGGREGATE
LTWT CONC
MATL
LIGHTWEIGHT CONCRETE
MATERIAL
EARTH
�� �� EARTH
o�°o.o °g
����og �� ° GRANULAR FILL
:. r...
SAND
3.
MAINTAIN ALL UTILITY SERVICE AND PROTECT EQUIPMENT AGAINST DAMAGE DURING
CONSTRUCTION. DO NOT INTERRUPT EXISTING UTILITIES SERVING OCCUPIED OR OPERATING
MAX
MAXIMUM
�0o 8°0�
ALUM
ALUMINUM
o°0
FACILITIES, EXCEPT WHEN AUTHORIZED IN WRITING BY THE BUILDING MANAGER AND
ANCH
ANCHOR, ANCHORAGE
MECH
MECHANICAL
AUTHORITIES HAVING JURISDICTION. IF REQUIRED BY THE OWNER, AT THE CONTRACTORS
ANOD
ANODIZED
MED
MEDIUM
EXPENSE, PROVIDE TEMPORARY SERVICE DURING INTERRUPTIONS TO EXISTING UTILITIES.
APP'D
APPROVED
MANUF
MANUFACTURER
PROVIDE NOT LESS THAN 10 WORKING DAYS PRIOR NOTICE TO THE OWNER AND BUILDING
ARCH
ASSOC
ARCHITECTURAL
ASSOCIATED
MIN
MISC
MINIMUM
MISCELLANEOUS
STEEL OR
MANAGER IF SHUTDOWN OF SERVICE IS REQUIRED.
AUTO
AUTOMATIC
METALS
ALUMINUM
4.
STRUCTURAL MEMBERS SHALL NOT BE CUT OR ALTERED, EXCEPT WHERE NOTED ON
AUX
AUXILIARY
MO
MASONRY OPENING
STAINLESS STEEL
DRAWINGS, WITHOUT AUTHORIZATION OF THE OWNER. WORK REMAINING IN PLACE WHICH IS
AVG
AVERAGE
MTD
MOUNTED
DAMAGED OR DEFACED DURING THE CONTRACT SHALL BE RESTORED TO THE CONDITION
BID
D
BOARD
MTG HT
MOUNTING HEIGHT
EXISTING AT TIME OF AWARD OF CONTRACT.
BUILDING
MTL
METAL
5.
CONSTRUCTION SHALL BE IN ACCORDANCE WITH U.L. LISTED RATED WALL ASSEMBLIES.
BLK
BLOCK
N/A
NOT APPLICABLE
6.
UNLESS OTHERWISE NOTED ON DRAWINGS OR SPECIFIED, NEW WORK IN EXTENSION OF
BOT
BOTTOM
NEC
NIC
NECESSARY
NOT IN CONTRACT
MASONRY
COMMON OR
CONCRETE
CUT STONE
EXISTING CONDITIONS SHALL CORRESPOND IN ALL RESPECTS WITH THAT TO WHICH IT
BSMT
BASEMENT
NTS
NOT TO SCALE
FACE BRICK
MASONRY UNIT
CONNECTS OR TO SIMILAR EXISTING CONDITIONS, IN MATERIALS, WORKMANSHIP AND FINISH.
BUR
BUILT UP ROOFING
NO,#
NUMBER
7.
ALL MATERIALS, INSTALLATION, AND WORKMANSHIP SHALL COMPLY WITH ALL APPLICABLE
CABT
CABINET
NOM
NOMINAL
STATE AND CITY CODES AND ORDINANCES, INDUSTRY STANDARDS, UTILITY COMPANY
CEM
CEMENT
OC
ON CENTER
REGULATIONS AND ALL REQUIREMENTS OF LOCAL AND FEDERAL AUTHORITIES HAVING
CER
CERAMIC
OD
OUTSIDE DIAMETER
JURISDICTION. MORE STRINGENT GUIDELINES FOR INSTALLATION AS ESTABLISHED BY THE
CHK'D
CHECKED
OH
OVERHEAD
�; �—
OWNER, PRODUCT MANUFACTURER, OR THE RELEVANT STANDARDS ORGANIZATION SHALL BE
CJ
CONTROL JOINT
OPENG
OPENING
CONCRETE
. ��::e:� '�. •' CONCRETE
" ` TERRAllO
STRICTLY FOLLOWED WITHOUT ADDITIONAL COST TO THE OWNER.
CL
CENTER LINE
OPP
OPPOSITE
8.
CONTRACTORS SHALL BE RESPONSIBLE FOR ADHERING TO ALL AT&T REQUIREMENTS AND
CLG
CEILING
PART
PAR
PARTITION
GUIDES GOVERNING WORK PERFORMED IN OCCUPIED SWITCH/OFFICE SPACES. ALL ISSUES
CLR
CLEAR
PL
PLATE
SHALL BE COORDINATED WITH AT&T PROJECT MANAGER.
CLOS
CLOSET
PL LAM
PLASTIC LAMINATE
9.
CONTRACTOR SHALL COORDINATE ALL DEMOLITION WORK AND NEW CONSTRUCTION WORK
CMU
CONCRETE MASONRY UNIT
PLMBG
PLUMBING
WITH PROJECT MANAGER AND BUILDING MANAGER TO MINIMIZE BUSINESS DISRUPTIONS WHILE
COL
COLUMN
PLAS
PLASTER
WOOD
FINISHED
ROUGH
PLYWOOD
NEW CONSTRUCTION IS IN PROGRESS.
CONC
CONCRETE
PLYWD
PLYWOOD
WOOD
WOOD
10.
PROVIDE PORTABLE FIRE EXTINGUISHERS DURING CONSTRUCTION OF BUILDING AS REQUIRED
CONT
CONTINUOUS
PR
PAIR
BY LOCAL CODES AND FIRE DEPARTMENT. FIRE EXTINGUISHERS MUST BEAR THE LABEL OF
CONTR
CONTRACTOR
PREFAB
PREFABRICATED
AN APPROVED AGENCY. NO DRY CHEMICAL EXTINGUISHERS ARE TO BE PLACED OR USED IN
COORD
COORDINATE
PROV
PROVIDE
TELECOMMUNICATIONS EQUIPMENT AREAS.
CPT
CARPET
PSF
POUNDS PER SQUARE FOOT
11.
CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS AND REPORT ANY DISCREPANCIES TO
CT
CERAMIC TILE
PSI
POUNDS PER SQUARE INCH
GYPSUM
RIGID
BATT
THE AT&T PROJECT MANAGER AND OWNER'S CONSTRUCTION REP.
CTR
CVB
CENTER
COVED VINYL BASE
PT
PVC
PAINT, POINT
POLYVINYL CHLORIDE
MISC.
• ' :
BOARD
INSULATION
INSULATION
12.
CONTRACTORS ARE TO CONFINE CONSTRUCTION TRAFFIC AND DEBRIS REMOVAL TO THE
CYL
CYLINDER
CONSTRUCTION AREA AS MUCH AS POSSIBLE TO MINIMIZE DUST MIGRATION. ERECT DUST
D
DEEP (DEPTH)
QT
R
QUARRY TILE
RADIUS, RISER
PARTITIONS WHERE DEMOLITION AND/OR NEW CONSTRUCTION ABUTS EXISTING FINISHED
DBL
DOUBLE
RB
RUBBER BASE
SPACES. SEE DUST PROTECTION SHEET
DEMO
DEMOLITION
RD
ROOF DRAIN
13.
CONTRACTOR SHALL COORDINATE STORAGE OF BUILDING MATERIALS AND THE REMOVAL AND
DEP
DEPRESSION, DEPRESS
REF
REFLECTEDREFERENCEREFER
, ,
ACOUSTICAL
° �°
CLEAN—UP OF ALL DEBRIS CAUSED BY HIS WORK DURING CONSTRUCTION. CLEAN ALL
"AS
DET
DETAIL
REINF
REINFORCEMENT
MISC.
MEMBRANE
TILE
e° PAVING
AREAS TO IS" CONDITIONS AT THE END OF EACH WORK DAY.
DF
DRINKING FOUNTAIN
RELOC
RELOCATE, RELOCATED
14.
SEE MECHANICAL, FIRE PROTECTION AND ELECTRICAL DRAWINGS, ETC., FOR ADDITIONAL
DIA
DIAMETER
REPL
REPLACE
WORK TO BE COORDINATED WITH THIS PROJECT AND THE REQUIREMENTS SPECIFIED HEREIN.
DIM
DIMENSION
REQ
REQUIRE, REQUIRED
15.
DIMENSIONS INDICATED ON PLANS ARE FROM FACE MATERIAL, I.E. FACE OF GYPSUM BOARD,
DN
DOWN
REV
REVISE, REVISION
CONCRETE BLOCK ETC.
DR
DOOR
ROOFG
ROOFING
16.
ROOM NUMBERS ARE SHOWN FOR REFERENCE AND CONSTRUCTION PURPOSES FOR THIS
PROJECT NAME:
DWG(S)
DRAWINGS)
RH
RIGHT HAND
PROJECT ONLY.
DWL
DOWEL
RO
ROUGH OPENING
EA
EACH
RM
ROOM
EL
ELEVATION
SCWD
SOLID CORE WOOD
ELECT
ELECTRICAL
SCHED
SCHEDULE
ELEV
ELEVATOR
SEAL
SEALANT
96TH STREET GARAGE
ENCLOS
ENCLOSURE
SHT
SHEET
MAINTENANCE BUILDING
GRAPHIC SYMBOLS
EQ EQUAL SIM SIMILAR
EQUIP EQUIPMENT SPEC(S) SPECIFICATION
AND SITE WORK
EXH
EXHAUST
SQ
SQUARE
EXIST
EXISTING
SS
STAINLESS STEEL
EXP EXPANSION, EXPOSED STD STANDARD
EJ
EXPANSION JOINT
STL
STEEL
EXIST
EXISTING
STRUC
STRUCTURAL (STRUCTURE)
COL-00255676-A1
EXT
EXTERIOR
SUSP
SUSPEND, SUSPENDED
FD
FLOOR DRAIN
SVB
STRAIGHT VINYL BASE
CONSULTANT STAMP
FDN
FOUNDATION
T
TOP, THICK
FIN
FINISH
T&B
TOP AND BOTTOM
Exp A/E, Inc.
FLR
FLOOR
T&G
TONGUE & GROOVE
t: +1.614.744.4300 I f: +1.614.744.4350 e®
FLEX
FLEXIBLE
TEMP
150 E. Gay Street =® m
FRP
FIBERGLASS REINFORCED
TERR
TERRAllO
Suite 1510
FT(')
FEET (FOOT)
THK
THICK, THICKNESS
bus, OH 43215 x r)
FTG
FURN
FOOTING
FURNISH, FURNITURE
THRU
TS
THROUGH
A
COLUMN CENTER —LINES
SPOT ELEVATION— EXISTING
ELEVATION TARGET
U.S.A. A
r •
www.exp.com
GA
GAUGE
TYP
TYPICAL
GALV
GALVANIZED
UL
UNDERWRITERS LABORATORIES
O
TOP OF STEEL ITEM BEING REFERENCED
GC
GENERAL CONTRACTOR
UNO
UNLESS NOTED OTHERWISE
�o
GEN
GENERAL
VAT
VINYL ASBESTOS TILE
+
+20I-o" DATUM ELEVATION
N•BUILDINGS •EARTH &ENVIROMENT •ENERGY•
GL
GLASS, GLAZING
VB
VINYL BASE
GRID LINE NUMBER
GYP. BD.
GYPSUM BOARD
VCT
VINYL COMPOSITION TILE
• •
INDUSTRIAL INFRASTRUCTURE • SUSTAINABILITY •
H
HIGH
VERT
VERTICAL
HCWD
HDW
HOLLOW ORE WOOD
HARDWARE
C
W
VINYL WALL COVERING
WATERCLOSET
CENTER LINE
SPOT ELEVATION— NEW
PARTITION TARGET
REVISIONS / AUTHORIZATIONS
HM
HOLLOW METAL
WT
WEIGHT
HORIZ
HP
HT(H)
HORIZONTAL
HIGH POINT
HEIGHT
WWF
W
W/
WELDED WIRE FABRIC
WIDTH, WIDE
WITH
PARTIAL SECTION
NIx
a PARTITION TYPE NUMBER
NO. REVISIONS / AUTHORIZATIONS DATE BY
HVAC
HEATING VENTILATING AIR—CONDITIONING
W/0
PERMIT ISSUE 06/26/20 M B
�
WWITHINITHOUT
WOOD
+
INFO
INFORMATION
Wp
WORKING POINT
1
SECTION NUMBER
BULLETIN 1 06/19/20 M B
INSUL
INT
INSULATE, INSULATION
INTERIOR
Al �
SHEET NUMBER
DOOR TARGET
ADDENDUM A 06/09/20 MB
WINDOW TARGET
I NEW DOOR 8c NUMBER
BID ISSUE 05/14/20 M B
DETAIL REFERENCE
4 WINDOW TYPE
CD ISSUE 2 05/07/20 MB
EXISTING DOOR
CID ISSUE 04/30/20 M B
2
� DETAIL NUMBER
ROOM NAME /NUMBER
DID ISSUE 04/09/2 MMB
A2
SHEET NUMBER
--
EXTERIOR ELEVATION
OFFICE ROOM NAME
PROPRIETARY AT&T INFORMATION
NOT FOR GENERAL USE OR DISCLOSURE OUTSIDE OF AT&T
101 ROOM NUMBER
Q ELEVATION NUMBER
THIS INFORMATION MAY ONLY BE USED BY AUTHORIZED
A6
PERSONNEL OF THE LOCAL GOVERNMENT AGENCY IN CONNECTION
SHEET NUMBER
WITH APPLICATION FOR PERMITS AND AUTHORIZATIONS FOR
DRAWING NUMBER, TITLE, SCALE
BUILDINGS, CONSTRUCTION, AND/ OR ZONING CHANGES.
BUILDING SECTION
GROUND FLOOR PLAN
INTERIOR ELEVATION
DRAWINGS PREPARED FOR
3
SECTION NUMBER
1 � = 1,_0�
/$
1 SHEET NUMBER
� CORPORATE
A3
� SHEET NUMBER
4 A5 2 � ELEVATION NUMBER
_=
�- REAL ESTATE
NORTH ARROW KEY NOTE
3
PROJECT DRAWING
MATCH LINE
O O
REVISION TARGET
A2.1
CURRENT SHEET NUMBER
A2.2
ADJACENT AREA
4160 E. 96TH STREET
� AREA OF REVISION
SHEET NUMBERc:::
INDIANAPOLIS
north
IN US
DEMOLITION WORK
1 REVISION NUMBER
LIMITS OF CONSTRUCTION
CRMLIN02 116427.01 N26102
— —
WALLS TO BE
SHEET TITLE:
— —
REMOVED
DIMENSIONING CONVENTIONS
GENERAL NOTES
ARCHITECTURAL
DOORS
TO BE
2' —0"
AT&T PROJECT NUMBER: DATE: — — — SCALE: —
/ REMOVED
--
M 2 8 3 0 4 DRAWN BY: — — — CHECKED BY: ---
AT&T AUTHORIZATION: SHEET: — OF: — SHEETS SHEET NO.
AT&T DRAWING NO.:
AT&T PM: NIGEL DOWNTON M28304A00001 A00001