HomeMy WebLinkAboutM100.0CEILING
WALL
FLOOR
T
COLD AIR RETURN
HVAC KEY
FLOOR SUPPLY REGISTER
WALL SUPPLY REGISTER
CEILING SUPPLY REGISTER
EXTERIOR WALL EXHAUST VENT
THERMOSTAT
DRYER BOX
G
W
GAS SHUT-OFF KEY
PLUMBING KEY
MAIN WATER SHUT-OFF
ICE MAKER BOX
LAUNDRY BOX
FROST PROOF HOSE BIB
CLEAN OUT
TILE-IN DRAIN
FLOOR DRAIN
ELECTRICAL KEY
REF. OUTLET
MICRO.OUTLET
DW POWER SUPPLY
HOOD VENT POWER SUPPLY
GB POWER SUPPLY
DIMMER SWITCH
SURFACE MOUNT LIGHT FIXTURE
6" RECESSED CAN LIGHT
4" RECESSED CAN LIGHT
6" RECESSED CAN/FAN UNIT
EXHAUST FAN ONLY
EXHAUST FAN W/ LIGHT
WALL MOUNTED SCONCE / LIGHT
CEILING FAN
LOW VOLTAGE LIGHT
SMOKE DETECTOR
MOTION SENSOR
CEILING SPEAKER
LOW VOLTAGE LIGHTING SWITCH
GARBAGE DISPOSAL SWITCH
COUNTERTOP AIR SWITCH
SINGLE POLE SWITCH
LOW VOLTAGE TRANSFORMER
220/240V OUTLET
EXTERIOR OUTLET
GFCI OUTLET
110V OUTLET
GAS COOKTOP
CLOTHS DRYER OUTLET
4-WAY SWITCH
3-WAY SWITCH
N
6" 3000K
MODEL NO.
6RLD G3
07LM 30K
90CRI 120
FRPC WWH
M6
DUPLEX
WHITE
TOGGLE
SWITCH
WHITE
UP
UP
FLOOR
FLOOR FLOOR
FLOOR
FLO OR
FLOOR
FLOOR
FLOOR
3
GFCI
3
T
J
3
C5/TV
4
3
R R
4
R
RR R R
R
L T L
R
R
R
R
R
R
R
RR R
RR R
3
M
DW
R
R
4
4
3
RR
R R
3
C5/TV
R
RR
R
4
R
3
GFCI
3
4
R
TL
L
RA
H
4
3
R4R4 GFCIGFCIGFCI
GFCI
GFCI
CO/SD
1'-3"2'-6 1/2" 1'-7 1/2"7'-4"4'-8"GARAGE
BATH
MUDROOM
DINING
OFFICE
LIVING
4 SEASONS
ROOM
PANTRY
BATH WIC
ENTRY
KITCHEN
H2H2
H3H3
H4H4
H5H5
H6H6
H1H1
P1P1
P2P2
P3P3
P4P4
E3E3
E4E4
E23E23
E34E34
E5E5
E6E6
E7E7
E1E1
E8E8 E9E9
E10E10
E11E11
E12E12E13E13
E14E14
E15E15E16E16
E17E17E18E18
E19E19
E20E20
E21E21
E22E22
E24E24
E25E25
E26E26
E27E27
E28E28
E29E29
E30E30
E31E31
E32E32 E33E33
E35E35
E36E36 E37E37
E38E38
E39E39
E40E40
E41E41
E42E42 E43E43
E44E44
E45E45
E43E43
E2E2
E46E46 E47E47
ELECTRICAL PLAN NOTES
GENERAL NOTE : CUSTOM LIVING TO PROVIDE ALL CAN
FIXTURES AND DECORATIVE FIXTURES UNLESS
SPECIFICALLY NOTED BELOW. ALL SWITCHES TO BE
STANDARD SWITCHES UNLESS NOTED.
GENERAL NOTE : ELECTRICIAN TO INSPECT EXISTING
SMOKE DETECTORS AND BRING UP TO CODE IF
APPLICABLE. THERE MAY BE ADDITIONAL COSTS
DEPENDING ON EXTENT OF WORK NEEDING TO BE DONE.
REINSTALL EXISTING CHANDELIER ON FINISH
INSTALL SINGLE 6" LED CAN LIGHT AND TIE INTO EXISTING
SWITCHING
PROVIDE ROUGH IN AND FINISH FOR (4) NEW 6" LED CAN
LIGHTS AS SHOWN
INSTALL NEW DINING ROOM DECORATIVE FIXTURE
PROVIDE NEW SWITCHES AS SHOWN
PROVIDE NEW REFRIGERATOR OUTLET
PROVIDE NEW OUTLET IN CABINET. FIELD VERIFY ROUGH
IN LOCATION.
PROVIDE ROUGH IN AND FINISH FOR (8) 6" LED CAN
FIXTURES AS SHOWN
PROVIDE ROUGH IN AND FINISH FOR (3) ISLAND PENDANTS
AS SHOWN
PROVIDE ROUGH IN AND FINISH FOR (2) DECORATIVE
ISLAND OUTLETS. FINISH TBD. CABINET INSTALLER TO CUT
IN BOXES ON SITE.
PROVIDE WHIP IN ISLAND FOR MICROWAVE DRAWER
PROVIDE OUTLET IN APPLIANCE GARAGE
PROVIDE POWER AND WIRING FOR LOW VOLTAGE
TRANSFORMER FOR UNDER CABINET LIGHTING. INSTALL
FINISH FOR LIGHTING. CUSTOM LIVING TO PROVIDE DRIVER
AND FIXTURES.
INSTALL STANDARD BACKSPLASH OUTLETS ACCORDING TO
CODE
PROVIDE ROUGH IN AND FINISH FOR (2) 4" RECESSED LED
CANS LOCATED ABOVE KITCHEN SINK WINDOW. FIXTURES
TO BE OVERALL CENTERED ON SINK.
PROVIDE POWER SUPPLY FOR GARBAGE DISPOSAL WITH
AIR SWITCH
PROVIDE POWER SUPPLY FOR DISHWASHER
INSTALL ROUGH IN AND FINISH FOR NEW SWITCHES AS
SHOWN.
PROVIDE POWER FOR DUAL FUEL RANGE AND HOOD VENT
PROVIDE ROUGH IN AND FINISH FOR (4) 6" LED CAN
FIXTURES
RELOCATE EXISTING SWITCHES FOR PROPOSED LAYOUT
PROVIDE ROUGH IN AND FINISH FOR NEW SWITCH LEGS
PROVIDE ROUGH IN AND FINISH FOR (2) 6" LED CAN
FIXTURES
PROVIDE ROUGH IN AND FINISH FOR NEW WALL OUTLETS
AS SHOWN. FIELD VERIFY ROUGH IN LOCATIONS.
PROVIDE ROUGH IN AND FINISH FOR HARDWIRED MOTION
LIGHT. FIXTURE SUPPLIED BY CL.
INSTALL FINISH FOR NEW VANITY SCONCE IN EXISTING
LOCATION
PROVIDE FIXTURE AND INSTALL ROUGH IN AND FINISH FOR
NEW BATH FAN / LIGHT UNIT AS SHOWN
PROVIDE FINISH FOR NEW CEILING FAN IN EXISTING
LOCATION
PROVIDE ROUGH IN AND FINISH FOR NEW SWITCH LEG AS
SHOWN
PROVIDE POWER FOR LOW VOLTAGE TRANSFORMER FOR
UNDER CABINET LIGHTING. INSTALL FINISH FOR UNDER
CABINET LIGHTING.
PROVIDE POWER FOR UNDER COUNTER REFRIGERATOR
UNIT AND SINGLE BACKSPLASH OUTLET
RELOCATE EXISTING SWITCHES FOR PROPOSED LAYOUT.
USE (1) EXISTING SWITCH FOR FAN FOR PROPOSED CANS.
PROVIDE ROUGH IN AND FINISH FOR (6) 6" LED RECESSED
CANS AS SHOWN
CAP EXISTING LOCATION OF CEILING FAN FOR FUTURE
LIGHT FIXTURE
PROVIDE ROUGH IN AND INSTALL FOR NEW TV CAT5 AND
OUTLET LOCATED ABOVE FIREPLACE SURROUND
EXISTING FIXTURES TO REMAIN
PROVIDE ROUGH IN AND FINISH FOR SINGLE SWITCH LEG
AND SINGLE 6" RECESSED LED TRIM AS SHOWN
PROVIDE ROUGH IN AND FINISH FOR NEW SURFACE
MOUNTED DECORATIVE FIXTURE
PROVIDE ROUGH IN AND FINISH FOR (2) NEW SWITCH LEGS,
(1) RECESSED CAN FAN, AND (1) VANITY SCONCE. FIELD
VERIFY SCONCE ROUGH IN LOCATION.
PROVIDE ROUGH IN AND FINISH FOR NEW WALL OUTLET
PROVIDE ROUGH AND FINISH FOR NEW SWITCH LEGS AS
SHOWN
PROVIDE ROUGH IN AND FINISH FOR (4) NEW 6" RECESSED
LED CANS AS SHOWN
PROVIDE ROUGH IN AND FINISH FOR NEW SURFACE
MOUNTED DECORATIVE FIXTURE AS SHOWN. CENTER
FIXTURE ON ROOM.
REPLACE (12) 6" CAN TRIMS IN BASEMENT W/ NEW LED
TRIMS TO MATCH NEW CANS IN HOME. TRIMS PROVIDED
BY CL.
REPLACE ALL ALMOND COLOR OUTLETS AND SWITCHES
ON 1ST AND 2ND FLOOR WITH WHITE DEVICES AND COVER
PLATES. *SITE VERIFY QUANTITIES*
E1E1
E2E2
E3E3
E4E4
E5E5
E6E6
E7E7
E8E8
E9E9
E10E10
E11E11
E12E12
E13E13
E14E14
E15E15
E16E16
E17E17
E18E18
E19E19
E20E20
E21E21
E22E22
E23E23
E24E24
E25E25
E26E26
E27E27
E28E28
E29E29
E30E30
E31E31
E32E32
E33E33
E34E34
E35E35
E36E36
E37E37
E38E38
E39E39
E40E40
E41E41
E42E42
E43E43
E44E44
E45E45
E46E46
E47E47
E1E1
E2E2
E3E3
E4E4
E5E5
E6E6
E7E7
E8E8
E9E9
E10E10
E11E11
E12E12
E13E13
E14E14
E15E15
E16E16
E17E17
E18E18
E19E19
E20E20
E21E21
E22E22
E23E23
E24E24
E25E25
E26E26
E27E27
E28E28
E29E29
E30E30
E31E31
E32E32
E33E33
E34E34
E35E35
E36E36
E37E37
E38E38
E39E39
E40E40
E41E41
E42E42
E43E43
E44E44
E45E45
E46E46
E47E47
HVAC PLAN NOTES
GENERAL NOTE: THERE IS CURRENTLY NOT AN
ALLOWANCE TO REPLACE ANY ADDITIONAL VENT COVERS
OTHER THAN THOSE SPECIFIED BELOW
ROUGH IN AND INSTALL NEW TOE KICK SUPPLY VENT BOOT
AND INSTALL WHITE METAL VENT COVER
CURRENT ALLOWANCE FOR HOOD VENT IS FOR CHARCOAL
RECIRCULATING VENT.
INSTALL NEW METAL, DECORATIVE FLOOR VENT COVERS
IN ALL AREAS OF NEW FLOORING. FINAL SELECTION: TBD
EXTEND EXISTING RETURN VENT DUCT IN DROPPED
CEILING ABOVE POWDER BATH AND INSTALL VENT FACE IN
OFFICE WALLS. INSTALL WHITE METAL VENT COVER.
INSTALL NEW EXTERIOR BATH VENT AND RUN DUCT TO
LOCATION OF BATH FAN FOR PROPOSED POWDER BATH.
H1H1
H2H2
H3H3
H4H4
H5H5
H6H6
H1H1
H2H2
H3H3
H4H4
H5H5
H6H6
PLUMBING PLAN NOTES
MOVE SINK ROUGH IN TO PROPOSED LOCATION AS
SHOWN. INSTALL FINISH FOR SINK FIXTURES
(UNDERMOUNT SINK WITH SINGLE DRAIN, BRIDGE FAUCET,
GARBAGE DISPOSAL WITH AIR SWITCH). APPLIANCE
INSTALLERS TO CONNECT DISHWASHER SUPPLY AND
DRAIN LINES FOLLOWING PLUMBING FINISH.
RUN NEW GAS LINE FOR DUAL FUEL SLIDE IN RANGE TO
LOCATION ACCORDING TO APPLIANCE SPECS.
RELOCATE FAUCET ROUGH IN FOR WALL MOUNTED
FAUCET. SITE VERIFY HEIGHT. CENTER FIXTURE ON
VANITY. INSTALL FINISH FOR NEW VANITY, FAUCET, SINK,
AND TOILET.
INSTALL ROUGH IN FOR PROPOSED POWDER BATH.
INSTALL NEW DRAIN LINE AND WATER LINE FOR TOILET
LOCATION. INSTALL DRAIN AND SUPPLY LINES FOR
PEDESTAL SINK. INSTALL FINISH FOR ALL FIXTURES AS
SHOWN.
P1P1
P2P2
P3P3
P4P4
P1P1
P2P2
P3P3
P4P4 BROWN RESIDENCEInterior Remodel1204 N Claridge WayCarmel, IN 46032Date:Revision:
6
SHEET OF 12
SIGNATURE / SEALDESIGNER: TYLER VARGOE: tylerv@customlivingusa.comC: 574.274.4155Client Initials:
Date:
The plans, including all text, drawings, concepts, and ideas
forming a part of the plans and the selection and arrangement
thereof are Copyright 2018 of Custom Living, Inc., Indianapolis,
IN. ALL RIGHTS RESERVED. The plans shall remain the
property of Custom Living Inc. Any use of the plans or their
content without the prior written permission of Custom Living Inc.
is strictly prohibited. CUSTOM LIVING5335 Winthrop AveIndianapolis IN 462207/1/2020
DATE:
[PRINTS TO SCALE IF PRINTED ON 24" X 36" ]
GENERAL M.E.P NOTES
HVAC Contractor is responsible for engineering
calculation necessary for correct sizing of new
equipment and ductwork being supplied,
fabricated and installed for the project.
HVAC ducts installed in unconditioned areas to
be insulated/sealed per current Code Standards.
HVAC contractor to start, test, and balance any
new equipment and ductwork to assure proper
operation of new systems.
Final plumbing materials selected may have an
affect on the final Plumbing Material and
Installation Budgets.
Owners understand that if additional plumbing,
electrical or ductwork is found in walls being
deleted that is not included on the plans there
will be a Change Order during construction to
relocate as necessary.
Owners understand that during mechanical
rough-ins there will be times when the water
service will be shut off to areas in the home.
Plumbing and Lighting fixtures supplied by
Owner will not be warranted by Custom Living
Plumbing and Lighting fixtures supplied by
Owner must be selected and on-site prior to start
of mechanical rough-ins.
PROPOSED M.E.P. PLAN - 1ST FLOOR
SCALE: 1/4" = 1'
RECESSED CAN LIGHTSNEW OUTLET DEVICE STYLE NEW SWITCH DEVICE STYLE CLOSET MOTION LIGHT - E26
EPCO-16540
7 WATT, 3000K
LED MOTION LIGHT
POWDER BATH VANITY LIGHT - E27 KITCHEN SINK SCONCE LIGHTS - E16 KITCHEN ISLAND PENDANTS - E10
DINING ROOM DECORATIVE LIGHT - E5CEILING FAN - E29 POWDER BATH VANITY LIGHT - E40 HALLWAY DECORATIVE LIGHT - E39
NEED TO FINALIZENEED TO FINALIZE NEED TO FINALIZE
NEED TO FINALIZENEED TO FINALIZE NEED TO FINALIZE NEED TO FINALIZE
07/02/20
Adam Schriner