Loading...
HomeMy WebLinkAboutS201.0N EXISTING 2X4 FRAMING DEMOLITION & FRAMING KEY NO DEMO IN THIS ROOM EXISTING 2X6 FRAMING WALL SECTION TO BE REMOVED NEW 2x4 FRAMING NEW 2X6 FRAMING BULK HEAD / LOWERED CEILING DN DN 2DB6036151DB27 BCB421818 BCB301818SB27SB273DB182DB6036153DB183DB18SB322DB242DB6036151DB27 BCB421818 BCB301818SB27SB27 3DB18 2DB603615 3DB183DB18 SB322DB24U722790 U242790W1551LW1551R W78450W28450 D17 3 113 1 1 3113631136 3 113 1 1 D12 D13EXISTING D14 D15 D16 CEILINGCEILINGCEIL I NG CEIL ING C EILIN G CEILING c L cL cL c L 4'-0 1/8"1'-8" 2'-7" 5' 8' 3'- 7 "3'-6 1/2"5 '-4"3'-3"1'-7 3/4"OPEN BELOW BEDROOM WIC MASTER BATH BEDROOM WIC WIC J&J BATH HALL BEDROOM BATH UTILITY CARPET CARPET CARPET NEW CARPET MASTER BDRM STRETCH AND RE-TUCK EXISTING CARPET OPEN BELOW NEW CARPET TILE VAULTED CEILING VAULTED CEILING C.H. 8' 0" CARPET VAULTED CEILING TILE TILE HALL NEW CARPET ATTIC ATTIC ATTIC ATTIC ATTIC CARPET CARPET NOT IN SCOPE OF WORK NOT IN SCOPE OF WORK NOT IN SCOPE OF WORK NOT IN SCOPE OF WORK NOT IN SCOPE OF WORK NOT IN SCOPE OF WORK GARDEN SHELF ABOVE CLOSET (BATHROOM SIDE) LAUNDRY BEDROOM CLOSET TILE VAULTED CEILING HARDWOOD F1F1 F2F2 F3F3F4F4 F5F5 F6F6 F7F7 F8F8 F6F6 F11F11 F12F12 F9F9 F10F10 DOOR SCHEDULE NUMBER QTY FLOOR SIZE R/O COMMENTS D01 2 1 2480 R IN 30"X98 1/2" HINGED D02 1 1 21080 36"X98 1/2" SLIDING BARN DOOR - MUDROOM SIDE D03 1 1 3380 41"X98 1/2" NEW DOORWAY D04 1 1 6880 81 3/4"X98 1/2" NEW DOORWAY D05 1 1 7080 86"X98 1/2" EXISTING DOORWAY, MAKE TALLER D06 1 1 3680 44"X98 1/2" NEW DOORWAY D07 1 1 10880 130"X98 1/2" NEW DOORWAY D08 1 1 4080 L/R IN 49 3/4"X98 1/2" GLASS FRENCH DOORS D09 1 1 2480 R 58"X98 1/2" POCKET DOOR D11 1 1 4080 50"X98 1/2" NEW DOORWAY D12 1 2 2668 32"X82 1/2" SLIDING BARN DOOR - BEDROOM SIDE D13 1 2 2468 L 58"X82 1/2" POCKET DOOR D14 1 2 2668 L IN 32"X82 1/2" RE-JAMB EXISTING LOUVERED SLAB D15 1 2 2668 R IN 32"X82 1/2" HINGED D16 1 2 2468 R IN 30"X82 1/2" HINGED D17 1 2 2868 L 66"X82 1/2" POCKET DOOR FRAMING PLAN NOTES INSTALL NEW SUBFLOOR AS NECESSARY FOLLOWING MECHNICAL RELOCATES INSTALL NEW DROPPED HEADER ABOVE SHOWER GLASS FRAME SHOWER CEILING DOWN (SITE VERIFY ROOF SLOPE AND CEILING HEIGHTS) FRAME NEW 14 1/2" W X 39" H SHOWER NICHE. SEE TILE LAYOUT FOR FINAL HEIGHT. FRAME IN OLD LOCATION OF CLOSET ENTRY DOOR FRAME NEW POCKET DOOR OPENING INSTALL ADDITIONAL BLOCKING IN WALL FOR BARN DOOR HARDWARE INSTALLATION FRAME NEW NON LOAD BEARING INTERIOR WALLS AS SHOWN. FRAME NEW DOORWAY (EXISTING LOUVERED DOOR TO BE REINSTALLED ON FINISH) FRAME NEW INTERIOR WALL AS SHOWN. FRAME BULKHEAD FLUSH WITH SIDE WALL, START BULKHEAD AT 40" O.F.F. AND FRAME TO CEILING. PROVIDE ADDITIONAL BLOCKING IN WALL FOR FLOATING SHELF INSTALLATION FRAME NEW NON LOAD BEARING INTERIOR WALLS AS SHOWN. FRAME NEW DOORWAYS AS SHOWN. FRAME NEW WALL FLUSH WITH ADJACENT WALL AS SHOWN F1F1 F2F2 F3F3 F4F4 F5F5 F6F6 F7F7 F8F8 F9F9 F10F10 F11F11 F12F12 F1F1 F2F2 F3F3 F4F4 F5F5 F6F6 F7F7 F8F8 F9F9 F10F10 F11F11 F12F12 1'-4" 9'HEADER- DOUBLE 2X8 (UNLESS NOTED OTHERWISE) DOUBLE TOP PLATE KING STUD CRIPPLE STUD SINGLE BOTTOM PLATE 2X10 FLOOR JOISTS @ 16" O.C. O.C.BROWN RESIDENCEInterior Remodel1204 N Claridge WayCarmel, IN 46032Date:Revision: 5 SHEET OF 12 SIGNATURE / SEALDESIGNER: TYLER VARGOE: tylerv@customlivingusa.comC: 574.274.4155Client Initials: Date: The plans, including all text, drawings, concepts, and ideas forming a part of the plans and the selection and arrangement thereof are Copyright 2018 of Custom Living, Inc., Indianapolis, IN. ALL RIGHTS RESERVED. The plans shall remain the property of Custom Living Inc. Any use of the plans or their content without the prior written permission of Custom Living Inc. is strictly prohibited. CUSTOM LIVING5335 Winthrop AveIndianapolis IN 462207/1/2020 DATE: [PRINTS TO SCALE IF PRINTED ON 24" X 36" ] PROPOSED FLOOR PLAN - 2ND FLOOR SCALE: 1/4" = 1' TYPICAL WALL FRAMING DETAIL SCALE: 1/4" = 1' GENERAL PROPOSED PLAN NOTES Framing contractors are responsible for all labor, for the scope of work specified on the drawings provided by Custom Living. Owner understands that Custom Living has only provided a labor and material allowance for the scope of Rough Carpentry work specified on the drawings. Any additional work added or uncovered during this scope will be filed as a Change Order during construction Owner understands that the drywall allowance is based on an estimated board count and square footage take-off. A final walk through with a drywall contractor after framing and mechanical rough-ins will be necessary to finalize drywall installation and finish budgets. Final drywall touch-ups will follow countertop installation. 07/02/20 Adam Schriner