Loading...
HomeMy WebLinkAboutShugars-Stamped Truss Drawings w Scissor (3)The truss designs referenced below have been prepared by me or under my direct supervision based on the truss design criteria and requirements ("design criteria") provided by Master Building ComponentsMaster Building Components. These truss designs are intended for the fabrication of individual building components that will perform to the design criteria provided. Any variance from the design criteria will render the affected truss designs inapplicable. Listed below are the truss designs included in this package and covered by this seal. Job: Shugars, JimmyShugars, Jimmy - 1126411 Shugars-24G_25, Shugars-24S_25 Any location identification is for file reference only. No determination of the appropriateness of design criteria for any specific project has been made in preparing the truss designs. Please refer to individual truss designs for specific design criteria. Arturo A. Hernandez (IN, PE-10606011) My license renewal date for the state of IN is 07/31/2020. IMPORTANT NOTE: The responsibility of the engineer sealing this package, as a Truss Engineer, is solely for design of individual trusses as individual building components based upon design criteria provided by others and set forth in the referenced truss drawings. The truss design criteria for the components have not been verified as appropriate for any particular building, project or use. Adequacy and suitability of design criteria and requirements for the truss designs for any specific project are the responsibility of the building designer, not the Truss Engineer, per ANSI/TPI-1, Chapter 2. 12300 Ford Rd, Suite 110 Dallas, Texas 75234 eaglemetal.com 1126411 0001/0004 1.The Truss Design Drawing(s) provided with these Design Notes have been prepared under and are subject to ANSI / TPI 1 published by the Truss Plate Institute, www.tpinst.org. Capitalized terms have the meanings provided in ANSI / TPI 1. 2.Copies of each Truss Design Drawing shall be furnished to the installation contractor, Building Designer, Owner and all persons fabricating, handling, installing, bracing, or erecting the trusses. DESIGN LIMITATIONS 3.The Truss Design Drawing is based upon specifications provided by the Building Designer in accordance with ANS1 / TPl 1. Neither the Truss Designer, Eagle, nor an engineer who seals this design (if any) assumes any responsibility for the adequacy or accuracy of specifications provided by the Building Designer. 4.The Building Designer is solely responsible for the suitability based upon the Truss Design Drawing and shall be responsible for reviewing and verifying that the information shown is in general conformance with the design of the Building. 5.Each Truss Design Drawing is for the individual building component (a truss). A seal on the Truss Design Drawing indicates acceptance of professional engineering responsibility solely for the individual truss. 6.Each Truss Design Drawing assumes trusses will be suitably protected from the environment. HANDLING, INSTALLING, & BRACING 7.Refer to Building Component Safety Information (BCSI) for handling, installing, restraining and bracing trusses. Copies can be obtained from the Structural Building Components Association, www.sbcindustry.com. 8.Bracing shown on each Truss Design Drawing is for lateral support of individual truss components only to reduce buckling lengths. All temporary and permanent bracing, including lateral load and diagonal or cross bracing, are the responsibility, respectively, of the erector and Building Designer. 9.Eagle is not responsible for improper truss fabrication, handling, erection or bracing. 10.Compression chords shall be laterally braced by the roof or floor sheathing, directly attached, or have purlins provided at spacing shown, unless noted otherwise. DESIGN NOTES REFERENCES •ANSI / TPI 1: National Design Standard for Metal Plate Connected Wood Trusses •BCSI: Building Component & Safety Information - Guide to Good Practice for Handling, Installing, Restraining, & Bracing of Metal Plate Connected Wood Trusses. •NDS: National Design Specification for Wood Construction •ESR: 1082 published by the International Code Council. www.icc-es.org SYMBOLS PLATE SIZE 3X4 - The first dimension is the width perpendicular to slots. Second dimension is the length parallel to slots. -, /, I, Indicates required direction of slots; Reference “Joint Details” for more information. 20 Ga Gr40 connectors required 3X10-20HS - 20 Ga Gr60 connectors required 8X10-18HS - 18 Ga Gr60 connectors required LATERAL BRACING When this symbol shown, continuous lateral bracing is required on the member of the truss. BEARING Indicates location where bearings (supports) occur. PLATE LOCATION & ORIENTATION The plate shall be centered on joint and/or placed in accordance with the design drawing/QC full scale details. 11.Bottom chord required bracing shall be at 1Oft spacing or less, if no structural rated ceiling is installed, unless noted otherwise. 12.Strongbacking shall be installed on all parallel chord trusses, including flooring systems, to limit deflection and reduce vibration. Refer to BCSI-B7. 13.Never exceed the design loading shown. Never stack building or other materials on inadequately braced truss; refer to BCSI. 14.Concentration of construction loads greater than the design loads shall not be applied to the trusses at any time; refer to BCSI. 15.Trusses shall be handled with care prior to erection to avoid damage. Refer to BCSI for recommended truss handling and erection. MATERIALS & FABRICATION 16.Lumber moisture content shall be 19% or less at the time of fabrication unless noted otherwise. 17.Lumber used shall be of the species and size, and in all respects, equal to or better than that specified. 18.Unless expressly noted, the truss designs are not applicable for use with fire retardant or preservative treated lumber. 19.Plates shall be applied on both faces of truss at each joint and embedded fully. Knots and wane at joint locations shall be regulated in accordance with ANSl / TPl 1. 20.For a specified plate gauge and grade, the specified size is a minimum. 21.Connections not shown are the responsibility of others. 22.Adequate support shall be provided to resist gravity, lateral and uplift loads. 23.For 4X2 truss orientation, locate plates 0 - 1/16” from outside the edge of the truss. 24.Fabrication of truss shall be in accordance with ANSI / TPI 1. OTHER NOTES 25.Camber is a non-structural consideration and is the responsibility of truss fabricator. 26.Do not cut or alter any truss member or plate without prior approval from a professional engineer. 27.Lumber design values are in accordance with ANSI / TPI 1; lumber design values are by others. 28.Install specified hangers per manufacturer recommendations. WARNING: Failure to follow may result in property damage or personal injury. 0420201126411 0002/0004 Master Building Components 109 Quinter Farm Road Union, OH 45322 Ph: 937-246-1414 Truss:Shugars-24G_25 Job: Shugars, Jimmy Designer:Rob Ridoutt Date: 06/01/20 07:35:26 Page: 1 of 1 Notes: All connector plates to be Eagle 20 gauge unless otherwise noted SPAN PITCH QTY OHL OHR CANT L CANT R PLYS SPACING WGT/PLY 24-0-0 4 /12 2 0-10-8 0-10-8 0-0-0 0-0-0 1 48 in 102 lbs ALL PERSONS FABRICATING, HANDLING, ERECTING OR INSTALLING ANY TRUSS BASED UPON THIS TRUSS DESIGN DRAWING ARE INSTRUCTED TO REFER TO ALL OF THE INSTRUCTIONS, LIMITATIONS AND QUALIFICATIONS SET FORTH IN THE EAGLE METAL PRODUCT'S DESIGN NOTES ISSUED WITH THIS DESIGN AND AVAILABLE FROM EAGLE UPON REQUEST. DESIGN VALID ONLY WHEN EAGLE METAL CONNECTORS ARE USED. TrueBuild® Truss Software v5.6.363 Eagle Metal Products 25-9-0 0-10-8 0-10-86-4-14 6-4-14 5-7-2 12-0-0 5-7-2 17-7-2 6-4-14 24-0-0 0-0-0 8-6-1 8-6-1 6-11-15 15-6-0 8-6-0 24-0-0 0-0-04-7-34-4-10-4-14 12 412 9 13x8 - 21.5x3 \ 35x5 - 41.5x3 / 53x8 - 10 64x4 -73x4 -84x4 - All plates shown to be Eagle 20 unless otherwise noted. Loading (psf) TCLL : 20 TCDL : 5(rake) BCLL : 0 BCDL : 5 General Bldg Code : IBC 2012/ TPI 1-2007 Rep Mbr : No Lumber D.O.L. : 115 % CSI TC : 0.53 (1-2) BC : 0.90 (8-1) Web : 0.26 (3-6) Deflection L/ (loc) Allowed Vert TL: 0.44 in L / 612 (5-6) L / 180 Vert LL: 0.23 in L / 999 (8-1) L / 240 Horz TL: 0.11 in 5 Reaction JT Brg Combo Brg Width Rqd Brg Width Max React Max Grav Uplift Max MWFRS UpliftMax C&C Uplift Max Uplift Max Horiz 1 1 8.5 in 1.84 in 1,557 lbs · -312 lbs -848 lbs -848 lbs 1 lbs 5 1 8.5 in 1.84 in 1,557 lbs · -312 lbs -848 lbs -848 lbs · Material Bracing TC: SYP 2400/1.7 2 x 4 TC: Purlins at 24 " OC, Purlin design by Others. BC: SYP 2400/1.7 2 x 4 BC: Purlins at 72 " OC, Purlin design by Others. Web: SPF #2 2 x 4 Loads 1) This truss has been designed for the effects of balanced (17.5 psf) and unbalanced sloped roof snow loads in accordance with ASCE7 - 10 with the following user defined input: 25 psf GSL, Terrain C, Exposure (Ce = 1.0), Risk Category II (I = 1.00), Thermal (Ct = 1.00), DOL = 1.15. Unobstructed slippery surface. If the roof configuration differs from hip/gable, Building Designer shall verify snow loads. 2) This truss has been designed to account for the effects of ice dams forming at the eaves. 3) This truss has been designed for the effects of wind loads in accordance with ASCE7 - 10 with the following user defined input: 120 mph (Factored), Exposure C, Enclosed, Gable/Hip, Risk Category II, h=14.17 ft, Overall Building Square Footage = 720 ft^2 (B=L=27), End Zone Truss, Both end webs considered. DOL = 1.60 4) Minimum storage attic loading has not been applied in accordance with IBC 1607.1 Member Forces Table indicates: Member ID, max CSI, max axial force, (max compr. force if different from max axial force). Only forces greater than 300lbs are shown in this table. TC 1-2 0.531 -3,681 lbs 2-3 0.524 -3,057 lbs 3-4 0.524 -3,057 lbs 4-5 0.531 -3,681 lbs BC 5-6 0.903 3,431 lbs (-1,491 lbs)6-8 0.524 2,209 lbs (-866 lbs)8-1 0.903 3,431 lbs (-1,491 lbs) Web 2-8 0.183 -927 lbs 3-8 0.262 1,068 lbs (-333 lbs)3-6 0.262 1,069 lbs (-333 lbs)4-6 0.183 -927 lbs Notes 1) Unless noted otherwise, do not cut or alter any truss member or plate without prior approval from a Professional Engineer. 2) Gable webs placed at 24 " OC, U.N.O. 3) Attach structural gable blocks with 1.5x4 20ga plates, U.N.O. 4) Bracing shown is for in-plane requirements. For out-of-plane requirements, refer to BCSI-B3 published by the SBCA. 5) The fabrication tolerance for this roof truss is 10 % (Cq = 0.90). 6) Building Designer shall verify self weight of the truss and other dead load materials do not exceed TCDL 5 psf. 7) Building Designer shall verify self weight of the truss and other dead load materials do not exceed BCDL 5 psf. 8) Design assumes minimum _x2 (flat orientation, visually graded) purlins attached to the top of the TC at purlin spacing shown with at least 2-10d nails. 9) Lateral bracing shown is for illustration purposes only and may be placed on either edge of truss member. 10) A creep factor of 1.50 has been applied for this truss analysis. 11) The “SYP” label shown in the “Material Summary” above indicates the new SPIB design values effective June 1, 2013 were used. 12)Indicates non-structural members. 13) Listed wind uplift reactions based on MWFRS & C&C loading. 1126411 0003/0004 Master Building Components 109 Quinter Farm Road Union, OH 45322 Ph: 937-246-1414 Truss:Shugars-24S_25 Job: Shugars, Jimmy Designer:Rob Ridoutt Date: 06/01/20 07:35:28 Page: 1 of 1 Notes: All connector plates to be Eagle 20 gauge unless otherwise noted SPAN PITCH QTY OHL OHR CANT L CANT R PLYS SPACING WGT/PLY 24-0-0 4 /12 7 0-10-8 0-10-8 0-0-0 0-0-0 1 48 in 89 lbs ALL PERSONS FABRICATING, HANDLING, ERECTING OR INSTALLING ANY TRUSS BASED UPON THIS TRUSS DESIGN DRAWING ARE INSTRUCTED TO REFER TO ALL OF THE INSTRUCTIONS, LIMITATIONS AND QUALIFICATIONS SET FORTH IN THE EAGLE METAL PRODUCT'S DESIGN NOTES ISSUED WITH THIS DESIGN AND AVAILABLE FROM EAGLE UPON REQUEST. DESIGN VALID ONLY WHEN EAGLE METAL CONNECTORS ARE USED. TrueBuild® Truss Software v5.6.363 Eagle Metal Products 25-9-0 0-10-8 0-10-86-5-4 6-5-4 5-6-12 12-0-0 5-6-12 17-6-12 6-5-4 24-0-0 0-0-0 12-0-0 12-0-0 1-10-9 12-0-0 24-0-0 0-0-04-7-34-4-10-4-14 12 412 2 12212 7 13x12 / 23x4 - 34x7 | 43x4 - 53x12 \ 8 68x10 - All plates shown to be Eagle 20 unless otherwise noted. Loading (psf) TCLL : 20 TCDL : 5(rake) BCLL : 0 BCDL : 5(rake) General Bldg Code : IBC 2012/ TPI 1-2007 Rep Mbr : No Lumber D.O.L. : 115 % CSI TC : 0.86 (1-2) BC : 0.90 (6-1) Web : 0.53 (3-6) Deflection L/ (loc) Allowed Vert TL: 1.18 in L / 229 (5-6) L / 180 Vert LL: 0.65 in L / 419 6 L / 240 Horz TL: 0.57 in 5 Reaction JT Brg Combo Brg Width Rqd Brg Width Max React Max Grav Uplift Max MWFRS UpliftMax C&C Uplift Max Uplift Max Horiz 1 1 8.5 in 1.81 in 1,561 lbs · -307 lbs -552 lbs -552 lbs 2 lbs 5 1 8.5 in 1.81 in 1,561 lbs · -307 lbs -552 lbs -552 lbs · Material Bracing TC: SYP 2400/1.7 2 x 4 TC: Purlins at 24 " OC, Purlin design by Others. BC: SYP 2400/1.7 2 x 4 BC: Purlins at 72 " OC, Purlin design by Others. Web: SPF #2 2 x 4 Web: One Midpoint Row: 2-6, 4-6 Loads 1) This truss has been designed for the effects of balanced (17.5 psf) and unbalanced sloped roof snow loads in accordance with ASCE7 - 10 with the following user defined input: 25 psf GSL, Terrain C, Exposure (Ce = 1.0), Risk Category II (I = 1.00), Thermal (Ct = 1.00), DOL = 1.15. Unobstructed slippery surface. If the roof configuration differs from hip/gable, Building Designer shall verify snow loads. 2) This truss has been designed to account for the effects of ice dams forming at the eaves. 3) This truss has been designed for the effects of wind loads in accordance with ASCE7 - 10 with the following user defined input: 120 mph (Factored), Exposure C, Enclosed, Gable/Hip, Risk Category II, h=14.17 ft, Overall Building Square Footage = 720 ft^2 (B=L=27), Not End Zone Truss, Both end webs considered. DOL = 1.60 4) Minimum storage attic loading has not been applied in accordance with IBC 1607.1 5) In accordance with IBC 1607.1, minimum BCLL's do not apply. Member Forces Table indicates: Member ID, max CSI, max axial force, (max compr. force if different from max axial force). Only forces greater than 300lbs are shown in this table. TC 1-2 0.857 -6,201 lbs 2-3 0.834 -4,557 lbs 3-4 0.834 -4,557 lbs 4-5 0.857 -6,201 lbs BC 5-6 0.900 5,884 lbs (-1,453 lbs)6-1 0.900 5,884 lbs (-1,453 lbs) Web 2-6 0.344 -1,815 lbs 3-6 0.533 2,174 lbs (-276 lbs)4-6 0.344 -1,815 lbs Notes 1) Unless noted otherwise, do not cut or alter any truss member or plate without prior approval from a Professional Engineer. 2) The fabrication tolerance for this roof truss is 10 % (Cq = 0.90). 3) Building Designer shall verify self weight of the truss and other dead load materials do not exceed TCDL 5 psf. 4) Building Designer shall verify self weight of the truss and other dead load materials do not exceed BCDL 5 psf. 5) Design assumes minimum _x2 (flat orientation, visually graded) purlins attached to the top of the TC at purlin spacing shown with at least 2-10d nails. 6) Lateral bracing shown is for illustration purposes only and may be placed on either edge of truss member. 7) A creep factor of 1.50 has been applied for this truss analysis. 8) The “SYP” label shown in the “Material Summary” above indicates the new SPIB design values effective June 1, 2013 were used. 9)Indicates lateral bracing required perpendicular to the plane of the truss at either the midpoint (one shown) or third points (two shown), bracing by others. See BCSI-B3 for additional information. 10) Listed wind uplift reactions based on MWFRS & C&C loading. 1126411 0004/0004