HomeMy WebLinkAboutE111 First Floor ElectricalLEGEND NEW CONSTRUCTION � POWEROUTLEf.DUPLEX �POWEROUiLEi. QUADRUPLEk �J JUNCiION BOX O CEILING MOUNTED JUNCiION BOX �8 BOX, BLANK COVER PLAiE � 80X,OPEN ❑P PROVIDE JUNCTION BO% ABOVE CEILING FOR POWER POLE CONNECTION. POWER POLE BY OiHERS. FLOOR BOX wliH POWER �� ANDDATAFWSH MOUNiED FLOOR BOX wliH J Va JUNCTION 80X AND DATA, FLUSH MOUMED DAiA/COMMl1NICAiION YJ OUTLEi IPROVIDE BOX AND PULL STR W G ONLV� DED DEDICAiEDCIRCIIIi GFCI GROUNDFAULiCIRCUIT iNTERRuar ounEr +42" HEIGHTOFELECiRIGAL OR DAiA DEVICE EXISTING TO REMAIN � POWEROUiLELDUPLEX � POWEROUiLEi. QUADRUPLEk � JUNCiION 80X O CEILING MOUNTED JUNCiION BOX Q BOX.BLANKCOVERPLAiE DO BOX.OPEN 0 POWERANDDAiAPOLE FLOOR BO% WITH POwER �I�' ANDDATA,FWSH MOUMED FLOOR BOX WITH �J IJ' JUNCTIONBOXAND DAiA, FWSH MOUMED p DAiNCOMMUNICAiION OUTLET GENERAL NOTES 1. iENANi'S FURNIil1RE VENDOR IS RESPONSIBLE FOR WSiALLATION OF FURNIiURE AND FIELD VERIFICAiION OF ALL CRITICAL DIMENSIONS. 2 ALLOUiLEfSARETOINSTALLEDIB"MIN.AFFTOTHEGEMEROF iHE DEVICE PER ADA GUIDELWES UNLESS NOTED OTHERWISE ALL NEw DEVICES AND FACE PLAiES i0 MAiCH EXISiING. 3. REFERiODOORSCHEDULEANDCOORDINAiEWIiH iENANT/O W NER REGARDING PO W ER LOCATIONS TO ACCOMMODAiE ELECiRIC STRIKES, CARD READERS AND/OR MAG-LOCKS CAkDREADEkSAREiYPICALLYINSTALLED9YTHE iENANT'S SEGURITY CONTRACTOR AND NOT SPECIFlED BY SDI. 4. CONiRACiOR TO PROVIDE GFlC Ol1iLEi FOR WAiER HEAiER AND AUTOMATIC SHUTOFF VALVES AS REQUIRED. 5. ELECTRICAL WORK 6 LIMIiED TO A DESIGN-BUILD SCOPE AND IS OUTLW ED IN THESE DRAWINGS. ALL ELECiRICAL WORK IS LIMITED i0 ADDIiIONS OR RELOCAiIONS OF ELECiRICAL OUiLEi DEVICES AND LIGHTING THAT DO NOT EXCEED THE CAPACIiY OF THE EkISiINGELECTRICALSERVICEINiHEBUILDING ELECTRICAL CONiRACiOR IS i0 NOTIFY APPLICABLE PARilE51F ADDIiIONAL WORK IS REQUIRED SO THAi ADDIiIONAL PLANS CAN BE FILED AND MUSi COMPLY W IiH ALL APPLICABLE CODES. � � � � Vw _ I O � O � Q O � � m � ? � �O .p - M � P QnL w a M N o c va�-3 c 3 iHIS DRA W ING. AND iHE IDEAS. DESIGNS AND CONCEPb CONiAwED HEREIN.AREiHEE%CLUSNE IMELLEQUAL PROPERiY OFSCHOII DESIGN. WG. AND ARE NOi i0 BE USED OR REPRODUCED IN WHOLE OR IN PARi, W IiHOUi iHE W RIIIEN CONSEM O=SCHOII DESIGN. N W `'� � O � r � Q W Z � - V=J N wC � ' < ~Z(9U � z� aoN� =~�a (1U� o Wz� �O� ��z O=o U � N ISSUE DAiE DESCRIPTION 05.11.]0 FEVIEW $ET 05.1].20 PERMIiSEi REVISIONS MAR DATE DB DESCRIPiION � AREA NOT IN CONTRACT � AREAOFWORK PLAN NOTES E01 PROVIDEPOWERANDDAiAFORTENANPSWALLMOUMED TELEV1510N AT HEIGHT NOiED ON PLAN. COORDINAiE EXACi LOCATION WITH TENANT. E02 PROVIDEFWSHMOUNTFLOORCOREWITHPOKETHRUDEVICE FOR ELECiRICAL, DAiA AN� DIRECi HDMI/vGA CONDUIi GONNECTION FROM FLOOR CORE POKETHRU DEVICE i0 WALL MOUMED MONIiOR. COOR�INATE WIiH iENANTS FURNITURE VENDORONEXACTLOCATION. PROVIDEPOKEiHRUDEVICE SUBMITfAL TO iENANi FOR APPROVAL PRIOR i0 ORDERING. IF POSSIBLE, CONVERT EXISTING BLANK/OPEN 80X TO NEW E03 RECEPTACLE AS SHOWN_ IF NOT POSSIBLE REMOVE BLANK/OPEN BOX AND PROVIDE NEW RECEPTACLE Ai iHIS LOCATION. ALL POWER SHOWN IN iHIS ROOM IS EXISTING AND IS TO REMAIN. E04 q�� ABOVE COUMER OUiLEiS ARE FOR DEDICAiED APPLIANCE USE ONLY. CONVENIENCE OUiLEiS ARE LOCAiED ELSEwHERE IN ROOM. E05 COORDINATE ALL POWER AND DATA REQUIREMENTS FOR iH15 ROOM W IiH iENANT. E06 PROVIDEDEDICAiEDOUTLEiFORTENANT'SCOPIERAiTHIS LOCATION AS NEEDED. ELECTRICAL PLAN 0 2' 4' 8' 16' � � - � li� =A� AR10700017 �� p C,ti STATE OF � � ? �ST �h' I ANP �'���� ,,��"'� q ni U��"• �--� �� PROJECT NUMBER 2020.057 PROJ. MGR DRAWN BY EH EH 1ST FLOOR ELECTRICAL PLAN N� E111 RELEA5E0 FOR CONSTRIICTI�N Su6jec� �o compliance with all regula�ions of S�a�e antl Local Codes City of Carmel r �un��\i lo•rvalM.�� . DATE: 07�06�20