HomeMy WebLinkAbout9 - E201 Electrical�
�!
i � � �
� - ' �- ' ....OFFICE _
T
� ��
r
'F01 ---%� 'Po1' etts - _',� �'
'F01' � , 1B1 4 �
� j� F01
n � F01 , -
LJ � 1
� ��� "� ei�
MT� ��
� � a _ _ J ` � .. �
a - j 1B1-15�
�,
� � a
._____ - � ,,, ,.o a
�� �
�
� �
I
�PARTIAL FIRST FLOOR PLAN - LIGHTING
SCALE: 1/8" = 1'-0"
NORTH
WP
182-23
�"8 j j1B1-10 1B1 10�' '-�
_
3 8 e ai A, , oFFice
B129
--' 1 B7 -8�i' _ y �'
I i181-10 i � 11
�^w` .. � � I _�
I
161 8
_ /
\
�y 1
�a 4U _-
i 1B7 10 -
__�� ��': � � � - --_� ,,...... A
181 40
2
�_ _ �
�' `�,L �1B1-10O2
t
C � _
16P 36 ' -
EDC A
Jr � uoow
I� /
� � r � ��L
� ",
��
161 -04
) _ �
1
eiz�
0
�� � 1B146
t�1-14�f�, ? 1B1�14 ;
J I `
i ,e, ,o
___ �
`- r
� _.
�PARTIAL FIRST FLOOR PLAN - POWER AND SIGNAL
SGALE: 1/e" = 1'-0"
NORTH
uu
i � �1
� /
�
� !
! n �
aiai �!�-' r "i "__' ,„,�
A� i"'_� 'F3 �
� ; ----,
� c� �"'-.i „ r"--
eiao 'Ew�' ��� i_ i
eizs -�)iB; "_�
� � i �"� , eixe
.._ `„"'J , '� I�""l
�
�.__�1 �
�:-- ' r��----- �"'$T ... ... L"'-i
siz�
� . '� _ ,a_r8��_ �
� , y
T O_
� 0 � � -�
`; .. . � - °-
f � ;
� I� ;� � _
. ._.._;.'.. ;i
�PARTIAL FIRST FLOOR PLAN - ELECTRICAL DEMOLITION
SGALE: 1/e" = 1'-0"
NORTH
RELEA5E0 FOR CONSTRIlCTION
Su6jec� �o compliance with all regula�ions
of S�a�e antl Local Codes
City of Carmel
r
�un��\i lo•rvalM��
DATE: 07�06�20
LIGHT FIXTURE SCHEDULE
TOTAL
MARK DESCRIPTION MOUNTING FIXTURE CRI WATTS COLOR LUMENS VOLTS MANUFACTURER(S)
WATTS
F01 LMEAR 4-INCH WI�E BV 8-FOOT LONG, WHITE RECESSED 86 80 10.75W/FT 3500K 875/FT 120 V FOCAL POINT FSM4L SERIES
DIFFUSER, 0-0OV DIMMING TO 10-PERCENL LAY-IN GRID
VERIFY GRID TVPE WITH ARCHITECT.
LIGHT FIXTURES
0 LIGHT.CEILING
O LIGHT.CEILING
b LIGHT. WALL
� ExiT sicN, wnu
� ERIT SIGN, CEILING
0 EMERGENCV LIGHT FI%TURE
SW ITCHES
So SWITCH,DIMMER
�Q MULTI-TECHNOLOGYCEILINGOCCl1PANCVSENSOR
Q PASSNE WFRAFED CEILMG OCCUPANCY SENSOR
az TWOPOLEWALLOCCUPANCVSENSOR
RECEPTACLES AND OUTLETS
� �UPLEX RECEPTACLE
� DOUBLE �UPLEX(QUA�)RECEPTACLE
� OUPLE%RECEPTACLEABOVECOUNTERTOPORTOGGLE
SW ITCH HEIGHT W HERE NO COUMER IS PRESENT
�OOUBLE DUPLEX (QUAD) RECEPTACLE A80VE COl1NTERTOP OF
TOGGLE SWITCH HEIGHT WHERE NO COUMER IS PRESENT
wa
GFCl/ WEATHERPROOF DUPLEX RECEPTACLE
O FLUSH FLOOR OUTLET,ONE DUPLEX RECEPTACLE UNLESS
NOTED OTHER W ISE
a TELECOMMUNICATIONSOUTLETWITHTWODATA
WNNECTIONS.
e
TELECOMMUNICATIONSOUTLET ExISTING.
, TELECOMMUNICATIONS OUTLET, ExISTING.
TYPICAL DEVICE DESIGNATIONS
-� LIGHT FIXTURE TVPE
F1'
SW ITCH LEG -� ��� GFCUIT NUMBEF
�
1
�� CIRCUIT NUMBER
Sa�- SWITCHLEG
3�- 3-W AY
CIRCUIT DESCRIPTIONS
CIRCUIT NUMBER:
PANELCIRCUIT NUMBER
(I.E. A7-1)
RACEWAYS
- - - CONDUIT, BELOW ROOR
ROOM CIRCUIT DESIGNATIONS
A,-,
CIRCUIT NUMBER
PANELNAME
FOOM CIRCIIIT DESIGNATION SHOWN ABOVE APPLY TO
EVERV DEVICE IN THE ROOM UNLESS NOTED OTHERW ISE
GENERAL NOTES - DEMOLITION:
1. FIELD VERIFV EXISTING CONOITIONS PRIOR TO BEGINNING WORK.
THESE DRAWMGS DO NOT SHOW ALL REQUIRED DEMOLITION WORK.
SOME CONDITIONS MAV HAVE BEEN CONCEALED DURING FlELD
$URVEVS.
2. DEVICESANDE�UIPMENTSHOWNDASHEDANDWITHHEAVVLWE
W EIGHT ON DEMOLITION DRAW MGS SHALL BE REMOVED IN THEIP
ENTIRETV, INCLUDING ALL W IRING TO SOURCE, UNLESS OTHERWISE
NOTED.
3. DISPOSALOFOEMOLISHEDMATERIALSSHALLCOMPLVWITHLOCAL,
STATE, AND FEDERAL REGULATIONS.
4. WNTFACTORSHALLPROTECTEXISTINGOWNERFACILITIESTHATARE
TO REMAIN DURMG CONSTRUCTION. ANV FACILITIES DAMAGED OR
DISCONNECTED BV CONTRACTOR SHALL BE IMMEDIATELV RESTORED
TO PREVIOUS CONOITION.
5. OWNER SHALL HAVE "RIGHT OF FlRST REFUSAC' FOR DEMOLISHED
ITEMS. CONTRACTOR SHALL COOR�INATE W ITH OW NER PRIOR TO
BEGINNING WORK TO DETERMINE WHATE ITEMS THE OWNER MAV BE
IMERESTED IN KEEPING. CONTRACTOF SHALL CAREFULLY REMOVE
SUCH ITEMS AND DELNER TO OW NER'S DESIGNATE� STORAGE AREA.
FOR ITEMS DEEMED OBSOLETE BV THE OWNER, CONTRACTOR SHALL
IMMEDIATELV REMOVE SUCH ITEMS FROM THE PREMISES, UNLESS
OTHEFWISE NOTED.
6 FOR MECHANICAL E�UIPMENT BEMG REMOVED, REMOVE ASSOCIATED
DISCONNECTS, CONTROLLERS, WIRING, ETG COMPLETE. VERIFV WITH
MECHANICALCONTRACTOR.
]. FOREQUIPMENTORDEVICESBEMGREMOVEDFROMWALLSTHATWILL
REMAIN, REMOVE E%ISTING DEVICE BO%AN� PATCH WALL, UNLESS
OTHERWISEREQUIREDORINSTRUCTED. RNISHCONDITIONSHALL
SHOW NO INDICATION OF PREVIOl1S INSTALLATION.
8. PROVIDE ADE�UATE SUPPORT FOR ExISTING CABLING/RACEWAVS
ABOVE CEILING AS REQUIRED. REMOVE OBSOLETE CABLING, WIRING,
RACEWAVS ETC.
9. REMOVEASSOCIATE�ELECTRICALFORANVEXISTINGWUIPMENT
BEINGFEMOVE�BVANVTRAOE. REFEFTOALL�RAWMGS.
10. CONTRACTOR SHALL REMOVE EXISTING DEVICES ON WALLS BEING
REMOVED, WHETHER DEVICES ARE SHOWN OR NOT, UNLE55
OTHERWISEINSTRUCTED.
11. COORDINATE SCHEDULING OF DEMOLITION WORK W ITH OWNER AN�
TRADES.
12. PATCH EXISTING HOLE$ THROUGH WALLS ANO FLOORS WHERE
EXISTING RACEWAVS OR CABLES ARE REMOVED.
13. FOR OEMOLITION OF RECESSED PANEL$ ANO SIMILAR EQUIPMENT,
COORDINATE WALL PATCH WITH GENERAL CONTRACTOR PRIOR TO
BEGINNING WORK.
� PLAN NOTES:
1. HUBBELL'SVSTEM ONE' NON-METALLIC FLOOR BOX q51 PFB WITH
ALUMINUMCOVER#SICFCAL. PROVIDEONEDUPLEXRECEPTACLE
AN� ONE STVLE LWE OPENING FOR TELECOMMUNICATIONS.
HUBBELLCATALOGNUMBERSISPDUSL PROVIDESUB-PLATESAS
REQUIRED. VERIFV FINAL LOCATION WITH ARCHITECT PRIOR TO
ROUGH-IN. PROVIDE SAW�CUT, TRENCH, FlLL, AND PATCH READY TO
RECEIVE FLOOR COVERMG.
2 EXISTINGRECEPTACLETOREMAIN. RECIRCUITASSHOWN.
LEGEND:
i i WORK TO BE FEMOVED
L _J
� WORKTOREMAIN
� WORK TO BE INSTALLED
GENERAL NOTES:
1. COOROINATE LOCATION$ OF DEVICES TO BE INSTALLEO IN CEILMGS W ITH THE
ARCHITECTURALREFLECTEDCEILINGPLANS. NOTIFVENGINEEROFANV
CONRICTS PRIOR TO INSTALLATION.
2 120 VOLT CIRCUITS SHALL UTILIZE SEPARATE INOEPENDENT NEUTRAL
CONDUCTORS. DO NOTSHARENEUTRALS.
3. CONTRACTORSHALLCOOR�INATEWITHALLTRADES. NOADDITIONAL
COMPENSATION WILL BE ALLOWED FOR INCORRECT WORK.OR FOR
W FRINGEMENT UPON OTHERS' W ORK, DUE TO A LACK OF COORDINATION.
4. DEVICESMGENERALSHALLBECENTEREDINWALLSPACEINWHICHTHEVARE
INSTALLED OR THEV SHALL BE SPACED SVMMETRICALLV (FOR EXAMPLE. CENTER
�EV ICES W HEN MOUNTEO ON FACE OF COLUMNS).
5. COORDINATE AND VEPoFV LOCATIONS OF DEVICES W ITH BLOCK COUPSING,
FINISH MATEFIALS. CASEWORK, ETC. PRIOR TO ROUGH-IN.
6. W IRING TO ALL RECEPTACLES ON DEDICATED CIRCUITS SHALL BE A MINIMUM #10
AWG UNLESS OTHERWISE NOTE�.
]. WIRINGSHALLBEMINIMUM#12AWGIN3/4"EMTCONDUITUNLESSOTHERWISE
NOTED OR REQUIRE�.
8. LOW VOLTAGE PLENUM�RATED CABLING (RRE ALARM, TELEPHONE/DATA. ETC.)
SHALL BE CONCEALEO ABOVE ACCESSBLE CEILINGS. FOR CABLES BEING
ROUTED THROUGH AREAS W ITH EXPOSED STRUCTURE OR INACCESSIBLE
CEILMGS, INSTALL CABLES IN MINIMUM 1�INCH CONDUITS.
9. REPLACEEXISTINGBLANKCOVERPLATESWITHNEW.FINISH/MATERIALTOMATCH
THOSE USED FOR NEW DEVICES.
10. �EVICE BOXES SHALL BE FLUSH MOUNTED AN� ALL RACEWAVS SHALL BE
CONCEALED. CONTFACTOR SHALL CUTAND PATCH EXISTING WALLS WITH
EXTREMECAl1TION,SOASTOMINIM2EINVASNENESSOFINSTALLATION. ROUTE
RACE WAVS SO AS TO MINIMIZE THE AMOUNT OF CUTTING AND PATCHING
RE�UIRED. PATCHINGSHALLCOMPLVWITHALLBIDDOCUMENTREQUIREMENTS.
11. EXISTING CONCEALED RACEWAVS AND DEVICE BO%ES MAV BE REUSED IN PLACE
IF DEEMED CODE COMPLIANT AND IN GOOD CONDITION. CONTRACTOR IS
RESPONSIBLE FOR VERIFlCATION.
12. PROVIDE FLUSH BACK BOXES AND CONCEALED RACEWAVS FOR THERMOSTATS.
SEE MECHANICAL DRAWINGS FOR LOCATIONS.
13. A MAXIMUM OF THREE SMGLE-PHASE CIRCUITS SHALL BE INSTALLED IN A SMGLE
CONDUIT.
14. COORDINATE EXACT LOCATION OF FLOOR OUTLETS AND OUTLETS AT TV
LOCATIONS AND SIMILAR LOCATIONS PRIOR TO POUGH-IN.
15. PROVIDEFIRESTOPPINGATALLPENETRATIONSTHROUGHFIRE-RATED
CONSTRUCTION.
16. ALL WARRANTIES REFERED TO ON THE DRAWINGS AND SPEGFICATIONS SHALL
BEGIN AT THE DATE OF SUBSTANTIAL COMPLETION AT THE END OF THE PROJECT.
1]. COOROINATE ALL CORE DRILLING W ITH STRUCTURAL ENGINEER.
18. CONTFACTOR SHALL COOFDINATE OCCUPANCY SENSOR LOCATIONS AND
ARRANGE FOR BESTOPERATION. COMMISSION AND COORDINATE OCCUPANCV
SENSOR OPERATIONAL SETTINGS W ITH OW NER DURING INSTALLATION. AT
COMPLETION OF PROJECT AND AFTEF OW NER OCCUPANCV, CONTFACTOR
SHALL MAKE ONE READJUSTMENT PER SENSOR AS DIRECTED BV THE OWNER.
19. ALL DEVICES ON WALLS SHALL BE INDNI�l1ALLY FED FROM ABOVE Q.E DO NOT
INSTALL FACEWAVS HORIZONTALLV IN WALL UNLE55 APPROVE�).
20. INSTALL ALL ABOVECEILING RACE WAVS AT LEAST ]-INCHES ABOVE CEILING TO
ALLOW FOR REMOVAL OF CEILING TILES AND LIGHTS.
21. DO NOT INSTALL RACEWAVS W FLOOR SLABS. INSTALL RACEWAVS BELOW SLAB
ON GRAOE AT LEAST 6-INCHES BELOW BOTTOM OF SLAB. FEEDER CONOUITS
SHALL BE AT LEAST 24-INCHES BELOW BOTTOM OF SLAB.
22 PROV IDE W IRE AND CON�UIT AS NEEOED TO MAINTAIN POW ER TO EXISTING
DEVICES TO REMAIN THAT ARE INTERRUPTED BV DEMOLITION OF ADJACENT
DEVICES.
23. PROVIDE DEVICES TO MATCH EXISTING. COLOR TO BE SELECTED BV ARCHITECT,
TVPICAL ALL DEVICES AND COVERPLATES.
A. �UPLEXRECEPTACLE-LEVITON5362-xx
B. SWITCH,DIMMER-EATONDFIOP-xx
C. MULTbTECHNOLOGYCEILINGOCCUPANCVSENSOR�EATONOAGDT4000-R
24. PROVIDE CAT 6 CABLE, JACKS. AND WALL PLATE BV COMMSCOPE TO MATCH
EXISTING.
25. HOMERUN �ATA CABLING TO EXISTING IOF B115.
702 North Capitol Avenue
Indianapolis, Indiana 46204
p 317 6363980
f 317 263-2073
www. rowlanddesign.com
LIBERTY FUND
- I
CONSULTANT
R.E. YIMOND ilNO A930GIFTE3 INC
]32 N CPPIIDLAVENl1E
woia�uavous m asma
,�me3.«„ onwzooas
�\ �SITY E ,y��
No.
+
-q PH9800083 `
9� 9TAlE0F �i
T
2
F
�
�
s`��ONALi�G
. '�7
:r,':il �.�_,
EXECUTIVE OFFICE
11301 N. MERIDIAN
STREET
CARMEL, IN 46032
06/01/2020
CONSTRUCTION
DOCUMENTS
NO. DESCAIPTION DATE
PROJECTNUMBER 20.007
SHEET ISSUE DATE OB/0112020
DRAWN BV DK
CHECKEDBV TEH
PARTIAL FLOOR PLAN -
ELECTRICAL
I �'��j �
RowLA�n � �Es��N
APCHITECTONE INTEPIOFS GPAPHICS