Loading...
HomeMy WebLinkAbout9 - E201 Electrical� �! i � � � � - ' �- ' ....OFFICE _ T � �� r 'F01 ---%� 'Po1' etts - _',� �' 'F01' � , 1B1 4 � � j� F01 n � F01 , - LJ � 1 � ��� "� ei� MT� �� � � a _ _ J ` � .. � a - j 1B1-15� �, � � a ._____ - � ,,, ,.o a �� � � � � I �PARTIAL FIRST FLOOR PLAN - LIGHTING SCALE: 1/8" = 1'-0" NORTH WP 182-23 �"8 j j1B1-10 1B1 10�' '-� _ 3 8 e ai A, , oFFice B129 --' 1 B7 -8�i' _ y �' I i181-10 i � 11 �^w` .. � � I _� I 161 8 _ / \ �y 1 �a 4U _- i 1B7 10 - __�� ��': � � � - --_� ,,...... A 181 40 2 �_ _ � �' `�,L �1B1-10O2 t C � _ 16P 36 ' - EDC A Jr � uoow I� / � � r � ��L � ", �� 161 -04 ) _ � 1 eiz� 0 �� � 1B146 t�1-14�f�, ? 1B1�14 ; J I ` i ,e, ,o ___ � `- r � _. �PARTIAL FIRST FLOOR PLAN - POWER AND SIGNAL SGALE: 1/e" = 1'-0" NORTH uu i � �1 � / � � ! ! n � aiai �!�-' r "i "__' ,„,� A� i"'_� 'F3 � � ; ----, � c� �"'-.i „ r"-- eiao 'Ew�' ��� i_ i eizs -�)iB; "_� � � i �"� , eixe .._ `„"'J , '� I�""l � �.__�1 � �:-- ' r��----- �"'$T ... ... L"'-i siz� � . '� _ ,a_r8��_ � � , y T O_ � 0 � � -� `; .. . � - °- f � ; � I� ;� � _ . ._.._;.'.. ;i �PARTIAL FIRST FLOOR PLAN - ELECTRICAL DEMOLITION SGALE: 1/e" = 1'-0" NORTH RELEA5E0 FOR CONSTRIlCTION Su6jec� �o compliance with all regula�ions of S�a�e antl Local Codes City of Carmel r �un��\i lo•rvalM�� DATE: 07�06�20 LIGHT FIXTURE SCHEDULE TOTAL MARK DESCRIPTION MOUNTING FIXTURE CRI WATTS COLOR LUMENS VOLTS MANUFACTURER(S) WATTS F01 LMEAR 4-INCH WI�E BV 8-FOOT LONG, WHITE RECESSED 86 80 10.75W/FT 3500K 875/FT 120 V FOCAL POINT FSM4L SERIES DIFFUSER, 0-0OV DIMMING TO 10-PERCENL LAY-IN GRID VERIFY GRID TVPE WITH ARCHITECT. LIGHT FIXTURES 0 LIGHT.CEILING O LIGHT.CEILING b LIGHT. WALL � ExiT sicN, wnu � ERIT SIGN, CEILING 0 EMERGENCV LIGHT FI%TURE SW ITCHES So SWITCH,DIMMER �Q MULTI-TECHNOLOGYCEILINGOCCl1PANCVSENSOR Q PASSNE WFRAFED CEILMG OCCUPANCY SENSOR az TWOPOLEWALLOCCUPANCVSENSOR RECEPTACLES AND OUTLETS � �UPLEX RECEPTACLE � DOUBLE �UPLEX(QUA�)RECEPTACLE � OUPLE%RECEPTACLEABOVECOUNTERTOPORTOGGLE SW ITCH HEIGHT W HERE NO COUMER IS PRESENT �OOUBLE DUPLEX (QUAD) RECEPTACLE A80VE COl1NTERTOP OF TOGGLE SWITCH HEIGHT WHERE NO COUMER IS PRESENT wa GFCl/ WEATHERPROOF DUPLEX RECEPTACLE O FLUSH FLOOR OUTLET,ONE DUPLEX RECEPTACLE UNLESS NOTED OTHER W ISE a TELECOMMUNICATIONSOUTLETWITHTWODATA WNNECTIONS. e TELECOMMUNICATIONSOUTLET ExISTING. , TELECOMMUNICATIONS OUTLET, ExISTING. TYPICAL DEVICE DESIGNATIONS -� LIGHT FIXTURE TVPE F1' SW ITCH LEG -� ��� GFCUIT NUMBEF � 1 �� CIRCUIT NUMBER Sa�- SWITCHLEG 3�- 3-W AY CIRCUIT DESCRIPTIONS CIRCUIT NUMBER: PANELCIRCUIT NUMBER (I.E. A7-1) RACEWAYS - - - CONDUIT, BELOW ROOR ROOM CIRCUIT DESIGNATIONS A,-, CIRCUIT NUMBER PANELNAME FOOM CIRCIIIT DESIGNATION SHOWN ABOVE APPLY TO EVERV DEVICE IN THE ROOM UNLESS NOTED OTHERW ISE GENERAL NOTES - DEMOLITION: 1. FIELD VERIFV EXISTING CONOITIONS PRIOR TO BEGINNING WORK. THESE DRAWMGS DO NOT SHOW ALL REQUIRED DEMOLITION WORK. SOME CONDITIONS MAV HAVE BEEN CONCEALED DURING FlELD $URVEVS. 2. DEVICESANDE�UIPMENTSHOWNDASHEDANDWITHHEAVVLWE W EIGHT ON DEMOLITION DRAW MGS SHALL BE REMOVED IN THEIP ENTIRETV, INCLUDING ALL W IRING TO SOURCE, UNLESS OTHERWISE NOTED. 3. DISPOSALOFOEMOLISHEDMATERIALSSHALLCOMPLVWITHLOCAL, STATE, AND FEDERAL REGULATIONS. 4. WNTFACTORSHALLPROTECTEXISTINGOWNERFACILITIESTHATARE TO REMAIN DURMG CONSTRUCTION. ANV FACILITIES DAMAGED OR DISCONNECTED BV CONTRACTOR SHALL BE IMMEDIATELV RESTORED TO PREVIOUS CONOITION. 5. OWNER SHALL HAVE "RIGHT OF FlRST REFUSAC' FOR DEMOLISHED ITEMS. CONTRACTOR SHALL COOR�INATE W ITH OW NER PRIOR TO BEGINNING WORK TO DETERMINE WHATE ITEMS THE OWNER MAV BE IMERESTED IN KEEPING. CONTRACTOF SHALL CAREFULLY REMOVE SUCH ITEMS AND DELNER TO OW NER'S DESIGNATE� STORAGE AREA. FOR ITEMS DEEMED OBSOLETE BV THE OWNER, CONTRACTOR SHALL IMMEDIATELV REMOVE SUCH ITEMS FROM THE PREMISES, UNLESS OTHEFWISE NOTED. 6 FOR MECHANICAL E�UIPMENT BEMG REMOVED, REMOVE ASSOCIATED DISCONNECTS, CONTROLLERS, WIRING, ETG COMPLETE. VERIFV WITH MECHANICALCONTRACTOR. ]. FOREQUIPMENTORDEVICESBEMGREMOVEDFROMWALLSTHATWILL REMAIN, REMOVE E%ISTING DEVICE BO%AN� PATCH WALL, UNLESS OTHERWISEREQUIREDORINSTRUCTED. RNISHCONDITIONSHALL SHOW NO INDICATION OF PREVIOl1S INSTALLATION. 8. PROVIDE ADE�UATE SUPPORT FOR ExISTING CABLING/RACEWAVS ABOVE CEILING AS REQUIRED. REMOVE OBSOLETE CABLING, WIRING, RACEWAVS ETC. 9. REMOVEASSOCIATE�ELECTRICALFORANVEXISTINGWUIPMENT BEINGFEMOVE�BVANVTRAOE. REFEFTOALL�RAWMGS. 10. CONTRACTOR SHALL REMOVE EXISTING DEVICES ON WALLS BEING REMOVED, WHETHER DEVICES ARE SHOWN OR NOT, UNLE55 OTHERWISEINSTRUCTED. 11. COORDINATE SCHEDULING OF DEMOLITION WORK W ITH OWNER AN� TRADES. 12. PATCH EXISTING HOLE$ THROUGH WALLS ANO FLOORS WHERE EXISTING RACEWAVS OR CABLES ARE REMOVED. 13. FOR OEMOLITION OF RECESSED PANEL$ ANO SIMILAR EQUIPMENT, COORDINATE WALL PATCH WITH GENERAL CONTRACTOR PRIOR TO BEGINNING WORK. � PLAN NOTES: 1. HUBBELL'SVSTEM ONE' NON-METALLIC FLOOR BOX q51 PFB WITH ALUMINUMCOVER#SICFCAL. PROVIDEONEDUPLEXRECEPTACLE AN� ONE STVLE LWE OPENING FOR TELECOMMUNICATIONS. HUBBELLCATALOGNUMBERSISPDUSL PROVIDESUB-PLATESAS REQUIRED. VERIFV FINAL LOCATION WITH ARCHITECT PRIOR TO ROUGH-IN. PROVIDE SAW�CUT, TRENCH, FlLL, AND PATCH READY TO RECEIVE FLOOR COVERMG. 2 EXISTINGRECEPTACLETOREMAIN. RECIRCUITASSHOWN. LEGEND: i i WORK TO BE FEMOVED L _J � WORKTOREMAIN � WORK TO BE INSTALLED GENERAL NOTES: 1. COOROINATE LOCATION$ OF DEVICES TO BE INSTALLEO IN CEILMGS W ITH THE ARCHITECTURALREFLECTEDCEILINGPLANS. NOTIFVENGINEEROFANV CONRICTS PRIOR TO INSTALLATION. 2 120 VOLT CIRCUITS SHALL UTILIZE SEPARATE INOEPENDENT NEUTRAL CONDUCTORS. DO NOTSHARENEUTRALS. 3. CONTRACTORSHALLCOOR�INATEWITHALLTRADES. NOADDITIONAL COMPENSATION WILL BE ALLOWED FOR INCORRECT WORK.OR FOR W FRINGEMENT UPON OTHERS' W ORK, DUE TO A LACK OF COORDINATION. 4. DEVICESMGENERALSHALLBECENTEREDINWALLSPACEINWHICHTHEVARE INSTALLED OR THEV SHALL BE SPACED SVMMETRICALLV (FOR EXAMPLE. CENTER �EV ICES W HEN MOUNTEO ON FACE OF COLUMNS). 5. COORDINATE AND VEPoFV LOCATIONS OF DEVICES W ITH BLOCK COUPSING, FINISH MATEFIALS. CASEWORK, ETC. PRIOR TO ROUGH-IN. 6. W IRING TO ALL RECEPTACLES ON DEDICATED CIRCUITS SHALL BE A MINIMUM #10 AWG UNLESS OTHERWISE NOTE�. ]. WIRINGSHALLBEMINIMUM#12AWGIN3/4"EMTCONDUITUNLESSOTHERWISE NOTED OR REQUIRE�. 8. LOW VOLTAGE PLENUM�RATED CABLING (RRE ALARM, TELEPHONE/DATA. ETC.) SHALL BE CONCEALEO ABOVE ACCESSBLE CEILINGS. FOR CABLES BEING ROUTED THROUGH AREAS W ITH EXPOSED STRUCTURE OR INACCESSIBLE CEILMGS, INSTALL CABLES IN MINIMUM 1�INCH CONDUITS. 9. REPLACEEXISTINGBLANKCOVERPLATESWITHNEW.FINISH/MATERIALTOMATCH THOSE USED FOR NEW DEVICES. 10. �EVICE BOXES SHALL BE FLUSH MOUNTED AN� ALL RACEWAVS SHALL BE CONCEALED. CONTFACTOR SHALL CUTAND PATCH EXISTING WALLS WITH EXTREMECAl1TION,SOASTOMINIM2EINVASNENESSOFINSTALLATION. ROUTE RACE WAVS SO AS TO MINIMIZE THE AMOUNT OF CUTTING AND PATCHING RE�UIRED. PATCHINGSHALLCOMPLVWITHALLBIDDOCUMENTREQUIREMENTS. 11. EXISTING CONCEALED RACEWAVS AND DEVICE BO%ES MAV BE REUSED IN PLACE IF DEEMED CODE COMPLIANT AND IN GOOD CONDITION. CONTRACTOR IS RESPONSIBLE FOR VERIFlCATION. 12. PROVIDE FLUSH BACK BOXES AND CONCEALED RACEWAVS FOR THERMOSTATS. SEE MECHANICAL DRAWINGS FOR LOCATIONS. 13. A MAXIMUM OF THREE SMGLE-PHASE CIRCUITS SHALL BE INSTALLED IN A SMGLE CONDUIT. 14. COORDINATE EXACT LOCATION OF FLOOR OUTLETS AND OUTLETS AT TV LOCATIONS AND SIMILAR LOCATIONS PRIOR TO POUGH-IN. 15. PROVIDEFIRESTOPPINGATALLPENETRATIONSTHROUGHFIRE-RATED CONSTRUCTION. 16. ALL WARRANTIES REFERED TO ON THE DRAWINGS AND SPEGFICATIONS SHALL BEGIN AT THE DATE OF SUBSTANTIAL COMPLETION AT THE END OF THE PROJECT. 1]. COOROINATE ALL CORE DRILLING W ITH STRUCTURAL ENGINEER. 18. CONTFACTOR SHALL COOFDINATE OCCUPANCY SENSOR LOCATIONS AND ARRANGE FOR BESTOPERATION. COMMISSION AND COORDINATE OCCUPANCV SENSOR OPERATIONAL SETTINGS W ITH OW NER DURING INSTALLATION. AT COMPLETION OF PROJECT AND AFTEF OW NER OCCUPANCV, CONTFACTOR SHALL MAKE ONE READJUSTMENT PER SENSOR AS DIRECTED BV THE OWNER. 19. ALL DEVICES ON WALLS SHALL BE INDNI�l1ALLY FED FROM ABOVE Q.E DO NOT INSTALL FACEWAVS HORIZONTALLV IN WALL UNLE55 APPROVE�). 20. INSTALL ALL ABOVECEILING RACE WAVS AT LEAST ]-INCHES ABOVE CEILING TO ALLOW FOR REMOVAL OF CEILING TILES AND LIGHTS. 21. DO NOT INSTALL RACEWAVS W FLOOR SLABS. INSTALL RACEWAVS BELOW SLAB ON GRAOE AT LEAST 6-INCHES BELOW BOTTOM OF SLAB. FEEDER CONOUITS SHALL BE AT LEAST 24-INCHES BELOW BOTTOM OF SLAB. 22 PROV IDE W IRE AND CON�UIT AS NEEOED TO MAINTAIN POW ER TO EXISTING DEVICES TO REMAIN THAT ARE INTERRUPTED BV DEMOLITION OF ADJACENT DEVICES. 23. PROVIDE DEVICES TO MATCH EXISTING. COLOR TO BE SELECTED BV ARCHITECT, TVPICAL ALL DEVICES AND COVERPLATES. A. �UPLEXRECEPTACLE-LEVITON5362-xx B. SWITCH,DIMMER-EATONDFIOP-xx C. MULTbTECHNOLOGYCEILINGOCCUPANCVSENSOR�EATONOAGDT4000-R 24. PROVIDE CAT 6 CABLE, JACKS. AND WALL PLATE BV COMMSCOPE TO MATCH EXISTING. 25. HOMERUN �ATA CABLING TO EXISTING IOF B115. 702 North Capitol Avenue Indianapolis, Indiana 46204 p 317 6363980 f 317 263-2073 www. rowlanddesign.com LIBERTY FUND - I CONSULTANT R.E. YIMOND ilNO A930GIFTE3 INC ]32 N CPPIIDLAVENl1E woia�uavous m asma ,�me3.«„ onwzooas �\ �SITY E ,y�� No. + -q PH9800083 ` 9� 9TAlE0F �i T 2 F � � s`��ONALi�G . '�7 :r,':il �.�_, EXECUTIVE OFFICE 11301 N. MERIDIAN STREET CARMEL, IN 46032 06/01/2020 CONSTRUCTION DOCUMENTS NO. DESCAIPTION DATE PROJECTNUMBER 20.007 SHEET ISSUE DATE OB/0112020 DRAWN BV DK CHECKEDBV TEH PARTIAL FLOOR PLAN - ELECTRICAL I �'��j � RowLA�n � �Es��N APCHITECTONE INTEPIOFS GPAPHICS