HomeMy WebLinkAboutC501 SITE UTILITY PLAN��
RELEA5E0 FOR CONSTRIlCTION �
Su6jec��ocompliancewithallregula�ions � � �
of S�a�e antl Local Codes
City of Carmel : S belOW.
p �efore you dig.
�un��\i lo•rvalM��'
SITE UTILITY PLAN
SCALE: 7'=10'
N
O
UTILITY NOTES
1. CON7RACTOR SHRLL BE RESPONSIBLE FOR OBTAINING OR VERIFYING THAT PERMRS
ANU APPROVALS RRE OBTAINED FRON THE RESPECTIVE CITV, COUNTY OR STAIE
AGQJqES PRKKt TO STARTING ANV fANSTRUCTION. PLL fANSTRUCTION MAIEPoPLS
AND WORKM4NSHIP SH4LL CONFORM TO 7HE LOCAL AUTHOMIES STPNDFRDS AND
SPECIFICATIONS.
2. REFER TO IXIS7ING TOPOCRIPHIC SURVEY FOR BENCHMARKS AND OTHER IXISTING
INFORIMTION. WNTRACTORTOFIELDVERIFYLAYOUTPRIORNCON57RUCTION.
3. CONIRACTOft SH4LL PROTECT HLL IXIS7ING AND NEY! CONSTRUC7NNJ FROM �AAIAGE.
SHOULDAN'/ DP/MGE OCCUR �MTRACTOR SHALL MAI� ALL NECESSARY REPAIRSAT
NOCOSTTO7HEOVMER.
4. CONiRACTOR SHPLL COORDINAIE WORK 'MiFI OTHER CONTRACTORS ON SITE.
CONiRACTOR SNPLL BE RESPONSIBLE FOR NOTFlCATION RNO COORUINATION OF ALL
CONS7RUCTION WITi 7ME RESPECTNE UTIUTY PROVIDERS PRqR TO STNi11NG ANY
CONS7RUCTION.
5. CONTRACTOR IS RESPONSIBIE Fqt OETERMINING THE EXACT LOCATION OF ALL
UTILITIES IN THE VICINRV OF THE CONSTRIICTIIXJ AREA PkIOR TO STARTING ANV
CONSikUCTION.
8. CALL 'HOIEV AKKEY', 7�BOP38155N, 72 HOURS PRIOR TO 7HE START OF MlV
EXCAVATION.
7. CONiRACTOR SHALL BE RESPoNSIBLE TO MAI� AVAIIABIE TO THE ENGINEER
DIMENSIONS TO LOCATE U7ILITV S7U&S PNDIOR ANV IITILITY CONDIIR S7U&S
INSTALLED.
B. ALL UIIUTV CROSSINGS OR 1RENCHES WIIHIN FIVE (5) FEEf OF THE EDGE OF
PAVEMEN� SHPLL BE BACIffILLEU TO 1HE SUBGRROE WRH GRANUWi MRTERIAL (p8
STONE�AND COMPACTED IN SIX (6) INCH LIFTS.
8. CONiRACTOR SXALL MAINTAIN A MINIMUM OF 18' VER71CP1 SEPARATION BEM14EEN
WATERAWNS, SPNRMY PND STORM SEWERS AS WELL AS A 17 HORIZONTAL
SEPAFA710NBEIWEEN WAIERMNNSANDSANRARVSEWERS.
10. CON7RACTOR SHRLL PROTECT RLL IXIS7ING AND NEVI CONSTRUC71(NJ FROh7 OAMAGE.
SHOULDANY DMMGE OCCIIR �NTRACTOR SHALL MAI� ALL NECESSARY REPAIRSAT
NOCOSTTOTHEOWNER
i1. ALL UTIUTV WOFK SMALL BE fAMPLEfm, INCLUDING TRENCH BACKFILL AND
COMPRCTION, PRIORTO PIACEMENTOiAN'l�RAVEL BASE.
12 FXCEPT FOR TH0.SE UTILITIES NOIED TO BE PLUGGED OR RQqVED, RECONNECT ALL
LINES ENCWNTERED WRING CONSikUCTION.
13. IRIUTV CONiRACTOR SHALL BE RESPONSIBLE FOR THE RAISING OR LOWERING OF ALL
E%ISTING MANHOIES AND CATCH BASINS, FW�MES AND COVERS, VALVE BO%ES AND
CLEAN-0UIS TO MEEf FINISH GRAOES.
14. ALL SRE UIILI7IES SHALL BE S7UBBED ANO PLUGGm TO WRHIN FIVE FEET OF THE
OIIfSIOE BUILDING FWNDATION WALL UNIESS OTHERIMSE NOIED.
15. REFER TO ARCHIIEC7lIRFllMECHANICAL MNS FIXi E%ACT BNLDING SANITARY AND
WATERSERVICEfANNECTIONLOCA710NS. FlELDAPIUSTASNECESSPRY.
18. IF PL7ERNATE STRUCNRES ARE TO BE SUPPLIm, SHOP ORAWINGS MUST BE
SUBMRTED TOTHE ENGINEERANDAPPROVED IN WRITING PRIORTOINSTOLlATION.
17. UfILITVlENG7NSNOlEDAREAPPROXIMATE.
18. ALLSTORMWATERINLEfSANDCATCHBASMSSMALLHAVE7HEWORDS'NODUMPING,
DRAINS TO STRENA', OR SIMIfARI.VPPPROVED MESS4GE CAST IN RNSEO OR
RECESSED LET7ERS AT A MINIMUM OF 7' IN HEIGHT IN ADDITION, ASYMBOL OFA FlSH
SHALL RLSO BE CAST WITH lHE IETTERS.
UTILITY LEGEND
IXISTING STORA7 SEWER
E UNDERGROUND EIECTRIC
W PftOPOSEDWAIERLINE
cas uNe
IXISTING SANITPRY MAIN
IXISTIN� SANITPRI' LAIERAL
'� IXISTINGFlREXYDRAM
^4 PROPOSEDWAIERVPLVE
° � 11ERN�011T
� SPNRAR'/M4NHOLE
STORMINLEf
STORM MANHOIE m
-- PROPoSEDSANITARYLATERAL
,GO. qtOPOSEDCLEAN-0UT
CARAIEL UPLRIES NOIES:
1. POSI—CAPS OR EQUNALENT PRE REQUIRED ON ALL WAIER VALVE
INSTPllATIONS.
2. BLUE REFLECTNE WARNING TAPE MUST BE MSTALLE� 18° ABOVE WATER LINES.
TRACER WIRE ALSO REQUIRED TO BE MSTALLED WIIH Pll WATER LINES.
CITY OF CARMEL NOTES:
1. UTILITY RELOCAPONS REQUIRED BY THE PROJECT SHALL BE THE
RESPONSIBILITY OF THE DEVELOPER. UPLITY LINE RELOCAPONS REOUIRED FOR
ROAD PROJECTS THAT RESULT IN A CONFLICT 'MTH PROPOSED DEVELOPMENT
SHALL BE 7HE RESPONSIBILITY OF THE �EVELOPER TO RESOLVE WITH iHE
UTILITY. E%ISPNG POLE LINES REQUIRED TO BE RELOCATED SHALL BE
RELOCATED TO WITHIN ONE FOOT OF THE PROPOSED RIGHT—OF—WAY LINE.
2 DAMAGE TO EXISiING RIGHT—OF—WAY SHALL BE RESTORE�/REPAIRED TO
THE SAiISFACiION OF THE CITY AT 7HE COMPLETION OF 7HE PROJECT. THE
WN7RACTOR IS ENCOURAGE� TO MSPECT THE RIGHT—OF—WAY'MTH 7HE CITY
PRIOR TO THE START OF WNSiRUCTION TO �OCUMENT iHE EXIS7ING
coNoinoN oF n{E Ricnr-oF-wnv.
3. CON7RACTOR SHALL PROTECT iHE EXISTING CITY DUAL DUCT BANK IN
THE RIGHT—OF—WAY. IN 7HE EVENT OF A WNFLICT W1TH 7HE PROPOSED
IMPROVEMENTS, RELOCATION OF THE �UAL �UCT AND ALL
ASSOQATED/APPURiENANT/ANQLLIARY IIEMS SHALL BE 7HE SOLE
RESPONSIBILITY OF THE DEVELOPER Sl1BJECT TO REVIEW AN APPROVAL BY
THE QTY.
C CINCLE DESIGN GHOUP
���. ���nn��
Engineer:
No.
910023
STAIE OF
.� ,
� r
� � t�
� � �I
KEY PLAN
CARMEL CITY CEN7ER
scuE xrs
vwi
Developer:
P E D C O R
�� �e�
DEVELOPMENT CO.
Pmject
�
`
O w
� W �
� U�
� � Z
�+ J �
U � �
J av
m U
�
a
Se[Issue Date Sheetlssue Date
DrawnoBy Checked By
iN�
Last Revision Date:
Qos .ao aoowo�M�
Sheet Title:
SITE UTILITY
PLAN
Sheet Number:
C501
DATE: 07�06�20