HomeMy WebLinkAboutA111 ArchitecturalARCHITECTURAL LEGEND
NEW CONSTRUCTION EXISTING TO REMAIN
WALL — WALL
W?
� PARiIALHEIGHTWALL � PARiIALHEIGHiWALL
�o WINDOW/SIDELIGHT a—� WINDOW/SIDELIGHi
#� DOORANDFBAME
(SEE DOOR SCHEDULE
XN DOORANDFRAME
WALL TYPES
NOiE:
ALL PLAN DIMENSIONS ARE FROM FACE TO FACE OF FINISHEO WALL.
ALL WALL$ ARE i0 BE Wl UNLE$$ OiHERWISE NOiED.
PROVIDE MOISiURE RESISiANT / GREEN BOARD AS REQUIRED IN
RESiROOM AND/OR SHOWER ROOMS.
NOi ALL wnLL iYPES LISTED BELOW ARE NECESSARILY USED ON THIS
PROJECi. REFER i0 REFLECiED CEILING PLAN FOR CEILING HEIGHTS.
W� WALLWIiHINSULAiION
3%q"MEfAL STUDS AT 16" O.C.;
ONE UYER OF s�g" iYPE "X" GYPSUM BOARD
EACH SIDE
EXTEND W ALL TO UNDERSIDE OF CEILING;
FlBERGLASS SOUND BAII INSULATION INSIDE
WALL AND 2'-0" EACH SIDE OF WALL ABOVE
CEILING
WZ PARTIAL HEIGHT WALL
3%g"MEiAL SiUDS Ai 16" O.C.;
ONE LAYER OF s/g" iYPE "X" GVPSUM BOARD
EACH SIDE
SEE ELEVAiION FOR WALL HEIGHi;
PROVIDE I"SiEEL PIPE ANCHORS INTO
CONCREiE FLOOR FOR SUPPORT AS
REQUIRED
DEMISWG WALLiO DEIX
W3 WIiHINSULAiION
35�g' MEiALSTURS Ai Ib" O.C:
ONE LAYER OF 5/g' TYPP'X" GYPSUM BOARD
EACH SIDE;
EXTEND W ALL TO UNDERSIDE OF DECK:
FIBERGLASSSOUNp BAif INSULATION INSIDE
WALL AND 2'-0" EACH SIDE OF WALL ABOVE
CEILING
W4 DEMISINGWALLWIiHSECURIiYMESH
35/a"MEiALSiUDSAi 16"QC
ONE LAYER OF 5/g' iYPE "X" GVPSUM BOARD
EACH SIDE;
EXiEN� WALL i0 UN�ERSIDE OF CEILING,
FIBERGLASS SOUN� BAII INSULAiION INSIDE
WALL AND Z-0" SOUND BAII INSOLAiION
EACH SIDE OF W ALL ABOVE CEILWG
PROVIDE MHAL SEWRIiV MESH ON iOP OF
WALL ABOVE CELWG i0 DECK
�
�
�
�
MEiALSTUD
EXISTWG WIN
MULLION
PRE-FINISHED ALUMINUM
RECENER TRIM - FAAEN Ai
WINDOW 9LL AND SET IN A
CONiINU0U5 BEA� OF
CAULKAi WINDOW MULLION
WHERE NEW WALLS MEEf.
iRIM COLOR i0 MAiCH
BUILDING WINDOW
MULLIONS.
LMEOFEXISiING WINDOW
SILL COVER BELOW
CONiINl10US BEAD OF
ACOUSiICAL $EALANi
A�I WALL AT MULLION DETAIL
GENERAL NOTES
L SEE ELECiRICAL PLAN FOR IMENDED FURNIiURE LAVOUi.
2 REFER i0 FINISH PLAN FOR ALL ACCENi/SPECIALiV PAINi OR
WALLCOVERING THAT REQUIRES LEVEL 4OR LEVEL 5 DRV WALL
FlNISH. REFER TO MANUFACiURER RECOMMENDAiIONS.
PLAN NOTES
AO� ALIGNFlNISHEDWALLSURFACES.PROVIDESAMETHIIXNESSSiUDSASE%ISiINGWALLATDOORWFlLLSORWHERENEWWALLSAREIN
LINE WIiH EkISiWG WALLS.
PROVIDE PLVWOOD PHONE BOARD, 4'x8xa'. PAINTED WITH FlRE REiARDANi PAINiTO MATCH ADJACENT WALL FlNISH. VERIFY
A0z LOCATIONWITHiENANTPRIORiOINSTALLAiION.
A03 NEWFlREE%iINGUISHERANDWHIiESEMFRECESSEDFlREE%iINGUISHERCABWETiOBEPROVIDEDANDWSTALLEDBVCONiRACiOR.
ALL FIRE EXTWGUISHERS ARE i0 BE PROVIDED BY iENANi AND INSTALLED ACCORDWG i0 NFPA 10-
A04 PROVIDEADDITIONALBLOCKINGINWALLASREQUIREDFORTENANT'SWALLMOUNTEDTELEVISION;COORDINATEEXAQLOCATION
wliH TENANT.
A05 CONFlRM THAT EXISTING WALL MAiCHES WALL TYPE "W l". IF NOi, ALTER EXISTING WALL AS REQUBED TO MATCH "W I".
A08 SUPPORi ISLAND COUNiERiOP AS REQUIRED WIiH CENiERLINE BRACKEi'S FRONi MOUNiING PLUS BRACKEi AiiACHED i0 MEiAL
STUDS WITH WOOD BLOCKINGAND DRVWALL INSTALLED OVER VERTICALSUPPORi. CASEWOFK CONTRACTORTO INSTALL BRACKEfS
AS NEEDED PRIOR TO INSTALLATION OF DRYWALL SUCH THAT VERiICAL PORTION OF SUPPORT IS CONCEALED BY DRYWALL.
COORDINATE APPROVAL OF SHOP DRAW WGS WIiH DRVWALL WSiALLAiION AS NEEDED_ REFER i0 ELEVAiIONS AND ENLARGED
PLANS FOR MORE INFORMAiION.
P01 PROVIDEPOiABLEHOTANDCOLDWAiERANDSANITARYWASTEANDVENTPIPINGFORSINKS.
REFER i0 LANDLORD FOR SOURCE OF HOT WAiER AND LOCATION ALLOWED IN iHIS BUILDWG. CONiRACiOR TO INSiALL
AUiOMAiIC SHUiOFF VA W ES AS REQUIRED.
P02 PROVIDEWATERLWEFORCOFFEEAND/ORREFRIGERATOR.CONFlRMLOCAiIONWIiHTENANT.
P03 pROVIDEALLNECESSARVPWMBINGANDDRAWSFORTENANiPROVIDEDDISHWASHERAiiHISLOCAiION_
�
�
�
V'w
_ I
O �
O
� Q O �
� m
� ? � �O
.p - M �
P Q� O
w a M N
O c
va�-3
c 3
iHIS DRA W ING. AND iHE IDEAS.
DESIGNS AND CONCEPb CONiAwED
HEREIN.AREiHEE%CLUSNE
IMELLEQUAL PROPERiY OFSCHOII
DESIGN. WG. AND ARE NOi i0 BE
USED OR REPRODUCED IN WHOLE OR
IN PARi, W IiHOUi iHE W RIIIEN
CONSENi OF SCHOII DESIGN.
N
M
O
�
�
� Z
�
� J
W w
F �
� N �
QYU
�
ZaN
Z � L
WzQ
JZ�
W �
� w
� �
� �
�
�
�
ISSUE
DATE DESCRIPTION
06.05.P0 REVIEWSET
06.05.20 PERMITSET
__________ _ F_ _II _
I�
b� a
gg 11'-92
(`� �
BREAK �
429 °
c )IV / E
�O u�so
2'-34�� 3�_
1
Anl
TYP. ��
� ENLARGED DIMENSION PLAN - BREAK 429
RELEA5E0 FOR CONSTRIICTI�N o� � 4
�
Su6jec� �o compliance with all regula�ions
of S�a�e antl Local Codes
City of Carmel
r
�un��\i lo•rvalM.�� .
DATE: 07�06�20
%
■
AREA NOT IN CONTRACT
AREA OF WORK
ARCHITECTURAL PLAN
0 2' 4' 8' 16' N�
� -
REVISIONS
MAR DATE DB DESCRIPiION
e It V 0'
3�4 AR10700017 f�?
'f S, STATE OFjC��
:c� i,y iAN ��'��
' , �"bR�iuni u"`",, -
�— /'�
PROJECT NUMBER
2019.520
PROJ. MGR DRAWN 8Y
EH AMM
4TH FLOOR
ARCHITECTURAL
FLOOR PLAN
Alll
WALL
THICKNESS
�