HomeMy WebLinkAboutE0.01-Electrical Cover Sheet1.G. D�R�ISS ARC�iITfCTS, «< a�� WALHALLA tOAD COLUMlUS, OHIO �s�o� la�l �os.n�o NOTE' ALL SVMBOLS MAV NOT APPLV (TYPICAL FOR ALL SYMBOL LEGENDS) ELECTRICAL SYMBOL LEGEND Xg CO�E�PLANNOTE yy DETAIL# %XX SHEET# REFERENCETAG XX EQUIPMENTDESIGNATION MDP-22 CIRCUITDESIGNATION PANEL OESIGNATION - CIRW IT NUMBER ELECTRICUTILITYKEVBOX 3 WALLSWITCH-NUMBERIN�ICATE52POLE,3 K � OR 4 WAY (NO NUMBER FOR SINGLE POLE] F� FAN/LIGHTCOMBINATIONFIXTURE $a LOWEROBECONTR011E��BYSWFTCHRE�S) OERHAUSTFAN $ DIMMERSWITCH Oj Jl1NCTI0N BOX �F CEILMG FAN SPEED CONTROL SWITCH � NON-FUSE�DISCONNECTSWITGH $K KEV-OPERATEDSWITCH � FUSEDDISCONNECTSWITCH $M MOTORRATEDDISCONNECTSWITCH 'a MOTOR � S OCWPANCYSENSORWALLSWITCH GREENGATE #ONW-0-0001-MV OR EQUAL O PUSHBUTTON $ R OVERRI�ESWITCH �g BUZZEWBELL $P� SWITCHWITHPILOTLIGHT LVT LOWVOLTAGETRANSFORMER T TIMERSWITCH � GREENGATE#TSW-MVORE�UAL � SINGLERECEPTACLE20A,12�V OS WALLMOUNTOCWPANCVSENSOR O GREENGATE#OAWC-0T-020WORE�UAL � SPECIALRECEPTACLE OS CEILINGMOl1NTOCQIPANCVSENSOR GREENGATE #OAG-0L2000-R OR E�UAL � DUPLEXRECEPTACLE20A.120V SP SWITCHPFCKFOROCCl1PANCVSENSOR � �UA�RUPLERRECEPTACLE20A,120V Pc PHOTOCELL � GFCI DUPLEX RECEPTACLE 20A, 120V TC TIMECLOCK � GFCI QUADRUPLEX RECEPTACLE 20A,120V ryp GURRENT LIMITING DEVICE � NUMBER INDICATES MAX AMPERAGE OF DEVICE � IG DUPLE%RECEPTACLE 20A, 120V pp POWER POLE � IGQUADRUPLEXRECEPTACLE20A,12�V -W a�CONDUITSTUBANDBOXFORWALL PHONE WIRING BY OTHERS � PLIT WIRE� DUPLEX REGEPTACLE 20A, 120 - a� CONDUIT STUB AND BOX FOR PHONE WIRING BV OTHERS � SPLITWIRED�VADRUPLEXRECEPTACLE a"CONDIIITSTUBANDBOXFORDATA 20A.120V � WIRINGBVOTHERS �T� TWISTLOCKRECEPTACLE � a"CONDUITSTUeAN�BOXFOR DATNPHONE WIRING BV OTHERS � FLUSH MTD AS INDICATE� BV BOX AROUND O TELEVISION OUTLET �EVICE, FLR=FLOOR, CLG-CEILWG _ Sl1RFACEMOl1NT WA WIRELESSACCESS PANELBOARD/LOADCENTER = FWSHMOUNTPANELBOFR�ILOA�CEMER MB ME�IABOXDEMARCLOCATION a UTILITYSERVIGEMETER p� OVERHEADPROJECTOR m PWGMOLD-SEEPLANVIEWFORSPEQFlC UPS UNWTERRUPTIBLEPOWERSUPPLY LENGTHS O ANNC GENERATORANNUNCIATOR ELECTRICAL NOTATIONS AC ABOVECOUNTER LV LOWVOLTAGE AFF ABOVEFINISHEDFLOOR MBJ MAINBON�INGJUMPER AFG ABOVEFINISHEDGRADE MC MECHANICALCONTRACTOR BPS BOLTE�PRESSURESWITCH MTD MOUMED CLG CEILINGMOUNTED NTS NOTTOSCALE CKT CIRCUR (PART) INDICATESCIRCUITUSEDELSEWHERE EC ELECTRICALCONTRACTOR PC PWMBINGCONTRACTOR EM EMERGENCV SSBJ SUPPLY-SIDEBONDINGJUMPER ETR EXISTINGTOREMAIN SUC SITEUTILITYCONTRACTOR FLR FLOORMOIIME� TVP TVPICAL FSC FIRESUPPRESSIONCONTRACTOR UG UN�ERGROUND GC GENERALCONTRACTOR UNO UNLESSNOTEDOTHERWISE GFCI GROUN�FAULTCIRWITINTERRUPTER WP WEATHERPROOF GFEP GROUNDFAULTE�UIPMENTPROTEGTION WG WIREGUARD GND GROUND WR WEATHERRESISTANT HC HVACCONTRACTOR XX" �IMENSIONEDHEIGHT IG ISOLATEDGROUND ELECTRICAL LINETYPE LEGEND ------------- GENERALDEMO GENERAL EXISTING ------------- SWITGHLEG — — — UGE — — — UN�ERGROUND ELECTRIC — — (AB)UGE — — UNDERGROUND ELECTRIC (ABANDONED) — — — (D)UGE — — — UNDERGROUND ELECTRIC (DEMO) — — (E)UGE — — UNDERGROUND ELECTRIC (EXISTING) LV LOWVOLTAGE (AB)LV LOWVOLTAGE�ABANDONED) — — — (D)LV — — — LOW VOLTAGE (DEMO) (E)LV LOWVOLTAOE�EXI3TIN0) — — UGLV — — UNDERGROl1ND LOW VOLTAGE — — (AB)UGLV — — UNDERGROUND LOW VOLTAGE (ABANDONED) — — — (D)UGLV — — — UNDERGROl1ND LOW VOLTAGE (DEMO) — — (E)UGLV — — UN�ERGROUND LOW VOLTAGE (EXISTING) MAM ELECTRICAL GENERAL NOTES: A. ALL ELECTRICAL INSTALLATIONS MUST COMPLY WITH THE NATIONAL ELECTRICAL CODE AN� ALL STATE AND LOCAL CODES ELECTRICAL SERVICE TO BE INSTALLED IN COMPLIANCE WITH NEC ARTICLE 230. B. CONTRACTORSHALLOBTAMFAULTCl1RRENTMPoRMATIONFROMIITILITVCOMPANVAND PERFORM SHORT CIRGUITCALCULATIONS. SRE FUSES AND EQUIPMENT A.IG RATINGS ACCORDINGLY. G CONTRACTORSHALLINSTALLASEPARATEE�UIPMENTGROUNDINGCON�UCTORSIZEDPER NEC TABLE 250.122 FOR ALL BRANCH CIRCUITS INSTALLED IN NON-METALLIC CONDUITS. METALLIC CONDUITS MAV BE USED AS EQUIPMENT GROUN�ING CONDUCTORS PER NEC. D. CONTRACTORSHALLVERIFYALLWIRESIZINGDUETOVOLTAGEDROPCAWEDBVIN-FIELD ROUTING / WSTALLATION �ISTANCES. E. SERVICE ENTRANCE EDUIPMENT SHALL BE GROUNDED WITH A SEPARATE COPPER OR AW MINIIM CONDl1CTOR AS INDICATED ON THE DRAWINGS AND PER ARTICLE 250.52(A) OF THE NATIONAL ELEGTRICAL WDE. GROUNDING CON�UGTOR SHALLAL50 BE GONNEGTE� TO A 518" DIAMETER X 8'-�" LONG GROUN� ROD FOR SUPPLEMENTAL GROUNDING PER NATIONAL ELECTRICAL CODE ARTICLE 250.54. F. CONTRACTOR IS RESPONSIBLE FOR LABELING ALL PANELS. DISCONNECTS. LIGHTING CONTROLLERS, ETC., AND ALL CIRCUIT BREAKERS IN THE DISTRIBUTION PANELS PRIOR TO PROJEGT COMPLETION. PROVIDE A TYPED �IRECTORY OF ALL CIRCUITS. BREAKERS USED FOR SWITCHWG SHALL BE RATED ACCORDINGLV. G. CONTRACTORSHALLSUPPLVANDINSTALLALLN.E.C.RE�UIREDE�UIPMENTDISCONNECTS (NOT ALL DISCONNECTS MAY BE SHOWN ON THE DRAWINGS). CONTRACTOR SHALL VERIFV ALL DISCONNECT SI➢NG WITH EACH EQUIPMENT NAMEPLATE RATING. H. CONTRACTOR IS RESPONSIBLE TO SECURE AND PAY FOR ALL PERMITS. CONTRACTOR SHALL COMPLY WITH ALL STATE LOCAL, AND NATIONAL CODES (EG., NATIONAL ELECTRICAL CODE). CONTRACTOR SHALL SCHEDULE INSPECTIONS SO JOB PROGRESS IS NOT DELAYED. I. CONTRACTOR SHALL Sl1PPLY AND INSTALL ALL E�IIIPMENT IN NEW CONDITION AN� LLL LISTED UNLESS NOTE� OTHERWISE. J. CONTRACTORSHALLMAKEARRANGEMENTSWITHLOCALPOWERCOMPANYFORTHE INSTALLATION OF NEW ELECTRICAL SERVICE AND METER. INSTALL NEW SERVIGE �ISTRIBUTION EQUIPMENT AS SPECIFIED ON ELECTRICAL DRAWINGS. N. CONTRACTORSHALLCOOR�INATEALLELECTRICALWORKWITHOTHERTRADESAND ARCHITECTURAL �RAWINGS TO ELIMINATE CONFLICTS. L. PRIORTOWNSTRUCTIONSTART.CONTRACTORSHALLSUBMITSHOP�RAWINGSAND OPERATION MANUALS FOR ALL EQUIPMENT AND ACCESSORIES FOR OWNER APPROVAL. M. CONTRACTOR SHALL PERFORM ALL WORK IN A NEATAND PROFESSIONAL MANNER. N. PROVIDE FLEXIBLE CON�UR FOR ALLVIBRATING EQUIPMENT. PROVIDE FLEXIBLE CONDUIT FOR LIGHT FIXTURE CONNEGTIONS. 0. CONTRACTOR IS RESPONSIBLE FOR VERIFYING ELECTRICAL E�IIIPMENT MPoRMATION WITH MANUFAGTURERS. WNTRACTOR SHALL PROVIDE ANY ADDITIONAL ELEGTRICAL WNNEGTIONS OR SERVICES TO EQUIPMENT WHICH ARE NOT SHOWN ON DRAWINGS. P. ALL PENETRATIONS OF WALL ROOF, AND CEILINGS TO BE SEALED AS REQUIRE� WITH U.L. APPROVED FIRE SEALANT TO MAINTAIN FIRE RATING AS REQUIRED. ALL ROOF PENETRATIONS, IF APPLICABLE, ARE TO BE COORDINATED WITH THE OWNER'S DESIGNATED ROOFlNG CONTRACTOR. Q. ELECTRICAL EDUIPMEM EXPOSED TO WFATHER CON�ITIONS SHALL BE WEATHERPROOF TVPE. CONDUIT EkPOSED TO WEATHER GONDITIONS OR IN GONTACT WITH CONCRETE SHALL BE POLVVINVL CHLORIDE (PVC) OR GALVANIZED HEAVV WALL STEEL (GRC�. R. ALL EXTERIOR RECEPTACLES SHALL BE WEATHER RESISTANT AS WELL AS WEATHERPROOF PER NEC 406.9. S. CONTRACTORSHALLSUBMITAS-BUILTDRAWINGSTOTHEOWNERIFWSTALLATIONVARIES FROM THE CONTRACT DRAWINGS. T. ANVCONDUITAN�WIRESRESSHOWNAREMINIMUMS.CONTRACTORSHALLINCREASESRES (DUE TO VOLTAGE DROP. QUANTITY OF CURRENT CARRVING CONDUCTORS IN THE SAME CONDUIT/RACEWAY. ETC.) AS RE�IIIRED BY THE N.EC. U. IG �EVICES QF APPLICABLE�: CONTRACTOR SHALL INSTALL AN ADDITIONAL CONDUCTOR FOR ISOLATED GROUND CIRCIIITS TO SUPPLV CONDIICTORS FOR ISOLATED 6ROl1NDING PURPOSES. SAID GROUNDING GON�UGTOR SHALL BE COVERE� WITH A CONTINUOUS OUTER FINISH THAT IS GREEN WITH ONE OR MORE YELLOW STRIPES. THE GROUNDING CONDUCTORS SHALL BE BONDED TO FRAME OF �EVICE AND Rl1N IN CONDl11T BACK TO'CENTRAC GROl1NDING BLOCK(S) AT SERVIGE DISTRIBUTION E�UIPMENT. V. ROOFTOPEQUIPMENTQFAPPLICABLE�:CONTRACTORSHALLINSTALLAWEATHERPROOF DISCONNECT FOR EACH UNIT. CONDUITS SHALL ENTER THE UNDERSI�E OF EAGH HVAC UNIT FROM WITHIN THE CURBED AREA FOR THAT UNR (THEREBY AVOIDING PENETRATIONS THROUGH THE ROOF MEMBRANE). IF J-BOX IS USED FOR Sl1PPLYIN6 POWER TO MULTIPLE UNITS, THE J-BO%MUST BE LOGATED WITHIN 25 FEET OF EACH UNIT'S DISCONNECT PER THE NE.G ARTIGLE 24021(B�(2). CONTRACTORSHALLSUPPLVANDINSTALLA120VACWEATHERPROOFGFCI RECEPTACLE WITHM 25' OF EACH 11NIT. W. ALLCONTRACTORS,PRIORTOBIDSUBMISSIONPROCESS,SHALLVISITPROPOSEDWORKSITE AND FlELD VERIFY ALL EXISTIN6 CONDITIONS. ANY CONDITIONS THAT DIFFER FROM THAT SHOWN ON THIS PLAN SHALL BE REPORTED TO THE ARCHITECTIENGINEER SO THAT NEW AND REVISED BID DRAWINGS OR INFORMATION MAY BE ISSUED. MODIFICATIONS TO SCOPE OF WORK WHICH RESULT FROM CONTRACTORS NEGLECT TO VISIT THE SITE PRIOR TO BID SUBMISSION SHALL BE CONTRACTOR'S SOLE RESPONSIBILITV. SHEET WFORMATION Prolect p: 20013 Issoed Fort BID / PERMIi Dafe: 5/29/20 Revkions'. :���\\\\`�� ��s r RR � ///���� � 0 E �O/? � o K' 2: 207 TATEOF ;��\ W � '�.1. P.�? � /////����///////II�IIIIIN���\\\\\\\\\ ., . �...� p.. � �,sLL_ U W w } o �� a } � N � � � N � U7 O � � in V U � � � � C C � p Q � �- N � O W — N � N o � N � � N U 6 N � C O L U N � N U �L �n� L � � � � t' 19 7q'7_\ 7q�7i�7:i Aveda Institute 16281 Tri Ridge Blvd Suite 140 Loveland, Ohio 45140 � PEServices ENGINEERING FOH VOUR 5U[[E55 1-513-836-3810 vwuw. pe-servi�es.com �.y:ieamne IT IS THE RESPONSIBILITY OF THE W NTRACTOR TO NOTIFY THEARCHITECT,LAN�LORDANDTENANTOFANY ELECTRICAL COVER DISCREPANCIES ENCOUMERED ON THE PLANS OR IN EXISTINGSITECONDITIONSPRIORTOSUBMISSIONOFBID. SHEET RELEA5E0 FOR CONSTRUCTION Suhjec� �o compliance with all regula�ions 04 S�a�e antl Local Codes City of Carmel `�y,:a���'.�`� �,�:;vaYa/„1��. DATE: O��0��20 BIDDERS ARE TO VISIT THE SITE AND FAMILIARRE THEMSELVES WITH EXISTWG CONDITIONS AND SATISFY THEMSELVES AS TO THE NATURE AN� SCOPE OF THE WORK. THE BASE BID SHALL REFLECT MODIFICATIONS TO SYSTEMS AND DEVICES AS REQUIRED BV STATE, LOCAL AND FEDERAL CO�ES WHETHER IN�ICATED OR NOT ON CONTRACT DOCUMENTS. THE SUBMISSIONS OF A BID WILL BE EVIDENCE THAT SUCH AN EXAMINATION AN� COMPLIANCE WITH GOVERNING CODESIREQUIREMENTS HAS BEEN MADE LATER CLAIMS FOR LABOR, E�UIPMENT, OR MATERIALS RE�UIRED, OR PoR DIFFlCULTIES ENCOl1MERED WHICH COULD HAVE BEEN FORESEEN HA� AN E%AMINATION AN� CODNREQUIREMENTS REVIEW BEEN MADE, WILL NOT BE ALLOWED. FYiIqi�RqJil:7q 7 E0.01