Loading...
HomeMy WebLinkAboutE0.02-Electrical Specifcations1.G. D�R�ISS ARC�iITfCTS, «< a�� WALHALLA tOAD COLUMlUS, OHIO �s�o� la�l �os.n�o 1.GENERAL: A. THE'GENERALWN�ITIONSOFTHECONTRACTFORCONSTRUCTION,"AIA�OCUMENTA201, LATEST E�ITION, AND THESE SPEQFICATIONS AS APPLICABLE ARE PART OF THIS CONTRACT. B. ALLAPPLICABLECO�ES,LAWSAN�REGULATIONSGOVERNINGORRELATINGTOANVPORTION OF THIS WORK ARE HEREBV INCORPORATED INTO AN� MA�E A PART OF THESE SPECIFICATIONS, AN� THEIR PROVISIONS SHALL BE CARRIED OUT BY THE CONTRACTOR WHO SHALL INFORM THE OWNER. PRIOR TO SUBMITfING A PROPOSAL OF ANV WORN OR MATERIAL WHICH VIOLATES ANV OF THE ABOVE LAWS AN� REGIILATIONS. ANV WORN DONE BY THE CONTRACTOR CAUSING SUCH VIOLATION SHALL BE CORRECTED BY THE CONTRACTOR. G INVESTIGATEEACHSPACETHROUGHWHICHEpUIPMENTMUSTBEMOVE�.WHERE NECESSARV, EQl11PMENT SHALL BE SHIPPE� FROM MANUFACTURER IN SECTIONS OF SIZE SUITABLE FOR MOVING THROUGH AVAILABLE RESTRICTNE SPACES. ASCERTAW FROM B111L�ING OWNER AND TENANT AT WHAT TIMES OF DAV EQUIPMENT MAV BE MOVED THROUGH ALLAREAS. �. �RAWINGSAREDIAGRAMMATICANDIN�ICATEGENERALARRANGEMENTOFSVSTEMSAN� WORK. WN�UIT ROUTING IS SHOWN DIAGRAMMATICALLV AN� �OES NOT SHOW ALL OFFSETS, �ROPS AN� RISES OF RUNS. THE CONTRACTOR SHALL ALLOW IN HIS PRICE FOR ROIITING OF CON�UIT TO AV01� OBSTRUCTIONS. E. INSTALL WORK SO AS TO BE RFADILV ACCESSIBLE FOR OPERATION. MAINTENANCE AND REPAIR. MINOR DEVIATIONS FROM �RAWINGS MAV BE MA�E TO ACCOMPLISH THIS, BUT CHANGES WHICH INVOLVE EXTRA COST SHALL NOT BE MA�E WITHOUT APPROVAL. F. THECONTRACTORSHALLKEEPALLEQUIPMENTAN�MATERIALS,ANDALLPARTSOFTHE BOIL�ING, EXTERIOR SPACES AND A�JACENT STREETS, SIDEWALKS AN� PAVEMENTS, FREE FROM MATERIAL AN� �EBRIS RESULTING FROM THE EXECUTION OF THIS WORK EXCE55 MATERIALS WILL NOT BE PERMITfED TO ACCUMIILATE EITHER ON THE INTERIOR OR THE EXTERIOR. G. SEALOPENINGSTHROUGHPARTITIONS,WALLSAN�FLOORSWITHMWERALWOOLOROTHER NONCOMBUSTIBLE MATERIAL. H. PROVI�EALLNECESSARVFLASHINGAN�COUNTERFLASHINGTOMAINTAINTHE WATERPROOFING IMEGRIN OF THE Bl11LDING AS RE�UIRED BV THE INSTALLATION OR REMOVAL OF CONDUIT AND EQUIPMENT. PROVIDE EQUIPMENT CURBS AS REQUIRED. I. THECONTRACTOR'SPROPOSALFORALLWORKSHALLBEPRE�ICATE�ONTHE PERFORMANCE OFTHE WORK DURING REGIILAR WORKING HOURS. WHEN SO �IRECTE�, HOWEVER, THE CONTRACTOR SHALL INSTALL WORK DIIRING OVERTIME HOURS AND THE ADDITIONAL COST TO BE CHARGED THEREFORE SHALL BE ONLY THE "PREMI OM" PORTION OF THE WAGES PAID. J. ALLMATERIALAN�E�UIPMENTSHALLBENEWUNLESSOTHERW6ENOTE�AN�SHALLBEIN ACCOR�ANCE WITH BUILDING STANDARDS. K. INSURANCP. IN ACCORDANCE WITH BUIL�ING REQUIREMENTS AN� SHALL INC W �E A HOLD HARMLE55 CLAIISE FOR OWNER AN� ENGWEER. L THEFINALACCEPTANCESHALLBEMA�EAFTERTHECONTRACTORHASADJUSTEDHIS EQUIPMENT, TESTE� THE VARIOUS SVSTEMS, �EMONSTRATED THAT IT FULFILLS THE REQUIREMENTS OF THE �RAWINGS AND SPEQRCATIONS AND HAS FURNISHE� ALL THE REQUIRE� CERTIFICATES OF INSPECTION AND APPROVAL. 2. SCOPE OF WORK: A. SCOPEOFWORKSHALLCONSISTOFPROVI�INGLABOR,MATERIALS.EQl11PMENT,SERVICES AN� FEES NECESSARV FOR COMPLETE AND SAFE MSTALLATION IN CONFORMITY WITH THE NATIONAL ELECTRICAL CO�E (NEC) AN� ALL OTHER APPLICABLE INOUSTRY. NATIONAL ANO LOCAL CODES AN� Al1THORITIES HAVING JURIS�ICTION, AS IN�ICATED ON DRAWINGS ANO HEREM SPECIFIE�. B. ALLORAWINGS.PLANS,OETAILS,SPECIFICATIONSAN�SPEQFICATIONA��EN�AAREMA�E PART OF THIS CONTRACT AN� SHALL APPLV TO ALL WORK UNDER THE CONTRACT UNLE55 OTHERWISE AMEN�E�. MO�IFIE�, SUPPLEMENTE� OR SPECIFIE� HEREIN. G THECONTRACTORSHALLFURNISHAWRITTENGUARANTEETOREPLACEORREPAIR PROMPRV AND ASSIIME RESPONSIBILITV FOR ALL EXPENSES MCIIRRED FOR ANY WORKMANSHIP AN� EQUIPMENT IN WHICH DEFECTS �EVELOP WITHIN ONE VEAR FROM THE �ATE OF FINAL CERTIFICATE FOR PAVMENT AN��OR FROM �ATE OR ACTUAL I15E OF EOl11PMENT OR OCCUPANCY OF SPACES BV OWNER INCLU�E� UNDER THE VARIOUS PARTS OF THE WORK, WHICHEVER �ATE IS EARLIER. THIS WORK SHALL BE �ONE AS DIRECTE� BY THE OWNER. THIS GUARANTEE SHALL AL50 PROVIDE THAT WHERE �EFECTS OCCUR, THE CONTRACTOR WILL ASSUME RESPONSIBILIN FOR ALL EXPENSES INCURRED IN REPAIRING AN� REPLAQNG WORK OF OTHER TRA�ES AFFECTE� BY �EFECT$ REPAIRS OR REPLACEMENTS M EQUIPMENT SUPPLIEO BV THE CONTRACTOR. �. THECONTRACTORSHALLGIVENECESSARYNOTICE,FILEDRAWINGSANDSPECIFICATIONS WITH ALL �EPARTMEMS HAVING JURIS�ICTION, OBTAIN PERMITS OR LICENSES NECESSARY TO CARRY OUT THIS WORK ANO PAV ALL FEES THEREFORE THE CONTRACTOR SHALL ARRANGE FOR INSPEQION AND TESTS OF ANY OR ALL PARTS OF THE WORK IF SO REpUIRE� BV AUTHORITIES AND PAY ALL CHARGES FOR SAME. THE CONTRACTOR SHALL PAV ALL COSTS FOR. AN� FURNISH TO THE OWNER BEFORE FINAL BILLING, ALL CERTIFICATES NECESSARY AS EVI�ENCE THAT THE WORK INSTALLED CONFORMS WITH ALL REGULATIONS WHERE THEY APPLV TO THIS WORK. 3. SHOP DRAWINGS: A. PRIORTOTHEINSTALLATIONOFANVWORKANDPROCUREMENTOFE�UIPMENT. CONTRACTOR SHALL PROVIOE COMPLETE SETS OF COORDINATED SHOP �RAWINGS OF ALL E�UIPMENT, IN�ICATWG CAPACITK DIMENSIONS AND SE�UENCE OF OPERATION FOR WRITfEN APPROVAL BY THE ARCHITECL ENGINEER, AND OWNER. B. IN�ICATE ON EACH SHOP DRAWIN6S SUBMITfED: t) PROJECT NAME AND LOCATION.2) NAME OF ARCHITECT AND ENGWEER. 3) ITEM IDENTIFlCATION.4) APPROVAL STAMP OF PRIME CONTRACTOR. C. SUBMISSIONSI�SUBMISSIONSIIIN.X1]IN.ORSMALLER�JFTHESUBMISSIONISACATALOG CUT, THEN THE CONTRACTOR SHALL SUBMIT ONE ORIGINAL AND TWO COPIES. OTHERWISE, HE SHALL SUBMIT THREE COPIES. THE ARCHITECT WILL PoRWARD THE ORIGINAL AND ONE COPV (TWO COPIES WHEN NO ORIGINAL IS RECBVE�) TO THE ENGWEER. ALL CATALOG CUTS SHALL BE COMPLETE 2) SUBMISSIONS LARGER THAN 11 IN. X n IN.: SUBMIT TWO PRINTS AND ONE PAPER SEPIA TO THE ARCHITECT. THE ARCHITECT WILL FORWARD ONE PRINT AND THE PAPER SEPIA TO THE ENGWEER. D. SUBMITSHOPDRAWINGSFORTHEPoLLOWING:1)SWITCHES.2)FUSE5.3�qRCUITBREAKERS. a) PANELBOARDS QNCLUDING DIMENSIONS. SCHEDULES, AND CATALOG CUTS�. 5) RACEWAYS. fi) WIRE AN� CABLE.1) WALL SWITCHES. 8) INSERTION RECEPTA0.ES.9) MOMENTARV CONTACT SWITCHES 10) TIME SWITCHES. t 1) SURFACE METAL RACEWAY. 12) LIGHTING LUMINAIRES.I3�TRANSFORMERS. 4. AS-BUILT DRAWINGS AND EQUIPMENT OPERATIONAL INSTRUCTIONS: A. UPONCOMPLETIONAN�ACCEPTANCEOFWORK,CONTRACTORSHALLFURNISHWRITTEN INSTRUCTIONS AND EpUIPMENT MANUALS AND �EMONSTRAiE TO THE OWNER THE PROPER OPERATION AN� MAINTENANCE OF ALL EpUIPMENT AND APPARATUS FURNISHED UNDER THIS CONTRACT. B. THESEINSTRUCTIONSSHALLBENPEDONB-V21N.X111N.PAPERAND800NDINTHREERING BINDERS WITH CLEAR ACETATE COVERS. CONTRACTOR SHALL GIVE THREE COPIES OF THE INSTRUCTIONS TO THE OWNER AND ONE COPY TO THE ENGINEER. G THEMSTRUCTIONBOOKLETSHALLBEARTHENAME,ADDRESSAN�TELEPHONENUMBEROF THE PROJECT, ARCHITECT AN� ENGINEER. D. REPRODUCIBLE"AS-BWLP'DRAWINGSSHALLBEPROVIDEDIN�ICATMGTHEASINSTALLED CONDITIONS OF THE WORK. "AS-BNLP' �RAWINGS SHALL BE PROVIDED TO THE ARCHITECT AFTER COMPLETION OF THE INSTALLATION. 5. GENERAL PROVISIONS FOR ELECTRICAL WORK: A. SPECIFICATIONSAREOFSIMPLIFIEOFORMANOMCLUOEMCOMPLETESENTENCES. WORDSORPHRASES SUCH AS'THE CONTRACTOR SHALL," "SHALL BEf "FIIRNISH," "PROVIDE; "'A." "THE;' AN� "ALL" HAVE BEEN OMITTE� FOR BREVIN. B. �EFINITION5:1�"PROVIOE":TOSUPPLY,INSTALLANOCONNECTUPCOMPLETEANOREAOVFORSAFEAN� REGIILAR OPERATION THE PARTICULAR WORK REFERREO TO UNLE55 SPECIFICALLY OTHERWISE NOTE�.2) "INSTALL"'. TO ERECT. MOUNT AN� CONNECT COMPLETE WITH RELATE� ACCESSORIES. 3) "FURNISH" OR "SUPPLV: TO PURCHASE, PROCIIRE, ACpUIRE AN� DELIVER COMPLETE WITH RELATE� ACCESSORIE5.4) "WORK"'. LABOR, MATERIALS, EpUIPMENT. APPARATl15. CONTROLS. ACCESSORIES AN� OTHER ITEMS REQIIIRED FOR PROPER AN� COMPLETE INSTALLATION.S�'WIRING". RACEWAY, FITTINGS, WIRE, BOHES AND RELATE�ITEM5.6)"CONCFALE�":EMBEDDE�INMASONRYOROTHERCONSTRUCTION,MSTALLE�IN FURRE� SPACES, WITHIN �OUBLE PARTITIONS OR HUNG CEILINGS, IN TRENCHES. IN CRAWL SPACES, OR IN ENCLOSURES. ])"EXPOSED": NOT INSTALLE� UNDERGROOND OR "CONCEALEO" AS �EFINED ABOVE. 0) "SIMILAR" OR "EpUAL". EpUAL IN MATERIALS. WEIGHT. SIZE, �ESIGN AND EFFIQENCY OF SPEQFIEO PRODUCT. C. TEMPORARYLIGHTAN�POWER'.PROVI�ETEMPORARYLIGHTAN�POWERSYSTEMSATEARLIESTPOSSIBLE �ATE WITHIN THE CONSTRUCTION AREAS FOR THE REQUIREMENTS OF ALL TRADES AS HEREIN DESCRIBE�. E%TEND SYSTEMS TO NEW CONSTRIICTION AS SOON AS PHVSICALLY POSSIBLE. MAWTAIN SYSTEM �URING WORKING HOURS OF ALL TRADES. COST OF ENERGY WILL BE PAID FOR BY OWNER. PROVIDE ALL REQUIRE� MAINTENANCE. INCLUDING LAMPS AND SOCKETS. �. OUALITY ASSURANCE:1) pUALITY AN� GAUGE OF MATERIALS: NEW, BEST OF THEIR RESPECTIVE KIN�S, FREE FROM DEFECTS AND LISTED BY UN�ERWRITERS LABORATORIES, MG, OR OTHER NATIONALLV APPROVED TESTING AGENCV AND BEARING THEIR LABEL. MATERIALS ANO EOUIPMENT OF SIMILAR APPLICATION SHALL BE OF SAME MANUFACTURER. EXCEPT AS NOTE�. 2) GUARANTEE: ALL MATERIALS AN� WORKMANSHIP SHALL BE GUARANTEE� AS �EFINE� IN PARAGRAPH 2C.3) CURRENT CHARACTERISTICS'. a. SERVICE'. 120/200 VOLT, 3 PHASE, 4 WIRE, 60 HERTZ WITH GROUNDE� NEUTRAL. b. DISTRIBUTION:120/208 VOLT, 3 PHASE, 4 WIRE, 60 HERTZ WITH GROUN�E� NEUTRAL. 4) HEIGHTS OF OUTLETS: (UNLE55 OTHEWISE SPEQFIE� BY ARCHITECT) a. FROM FINISHE� FLOOR TO CENTERLWE OF OUTLETS FOR'. - RECEPTACLES AND TELEPHONES 1'-6". - WALL SWRCHES'. 3'2". - WALL W MINAIRES: ]'-0". - MOTOR CONTROLLER5:5'�0". - STROBE LIGHTS'.6' 8'. OR fi" BELOW CEILING (WHICHEVER IS LOWER) - FIRE ALARM PULL STATION5:4'-0". b. E%CEPTIONS: AT JUNCTION OF DIFFERENT WALL FINISH MATERIALS, ON MOLDING OR BRFAK IN WALL SURFACE, IN VIOLATION OF CO�E, OR AS NOTED OR DIRECTE�. E. PRODUCT�ELIVERY,STORAGEANDHAN�LING:1)MOVINGOFEQUIPMENT:WHERENECESSARY,SHIPIN CARTED SECTIONS OF SIZE TO PERMIT PASSING THROUGH AVAILABLE SPACE5.2) ACCESSIBILIN'. FOR OPERATION, MAINTENANCE AN� REPAIR. MINOR �EVIATIONS SHALL BE PERMITTE�. CHANGES OF MAGNITU�E OR INVOLVING EXTRA WST ARE NOT PERMISSIBLE WITHOUT REVIEW. GROUP CONCEALE� ELECTRICAL EpUIPMENT REQl11RING ACCE55 WITH EpUIPMENT FREELY ACCESSIBLE THROUGH ACCESS 000Rs. F. MATERIALS'.1�NAMEPLATES:PROVI�EBIACKLAMIC0I�SHEETWITH%"WHITELETTERING,FASTENEDWITH EPDXV CEMENT FOR EACH �ISCONNECT SWITCH. CIRCUIT BREAKER, PANEL, CABINET, TRANSFORMER, ENCLOSURE,MOTORCONTROLLERAN�THELIKE NAMEPLATESSHALL�ESCRIBETHENAMEAN�Nl1MBER OF FACH COMPONENT. 2) CABLE TAGS'. TAG FACH CON�UCTOR PASSING THROUGH SPLICE OR PULLBOX WITH A WHITE LINEN TAG, IN�ICATING POI�T OF ORIGIN AN� TERMINATION OF THE CIRCUIT.3) INSERTS AN� SUPPORTS: a. MSERTS: STEEL, SLOTfED iVPE, FACTORY PAINTE�. - SINGLE RO�: SIMILAR TO GRINNELL FIG. 281. - MULTI-R0�'. SIMILAR TO FEE AN� MASON SERIES 9000 WITH EN� CAPS AN� CLOSURE STRIPS. - CLIP FORM NAILS F W SH WITH INSERTS. - MAXIMUM LOA�ING ]5 PERCENT OF RATING. b. SOPPORTS FROM BUILDING CONSTRl1CTI0N: MSERTS, BEAM CLAMPS, STEEL FISHPLATES QN CONCRETE FlLL ONLV), CANTILEVER BRACNETS OR OTHER MEANS. SUBMIT FOR REVIEW. c. GROUPE� LINES AN� SERVICES'. TRAPEZE HANGERS OF BOLTED ANGLES OR CHANNELS. d. WHERE BUIL�ING CONSTRUQION IS INAOEpUATE'. PROVIDE ADDITIONAL FRAMING. SUBMIT FOR REVIEW. G. PAINTSHALLBETHEBESTGRADEFORITSPIIRPOSE.DELNERINORIGINALSEALEDCONTAINERSANDAPPLV IN ACCOR�ANCE WITH MANUFACTURER'S INSTRUCTIONS. COLORS SHALL BE AS SELECTE� BY ARCHITECT OR ENGINEER. UTILIZE GALVANIZEO IRON PRIMER ON PANEL AN� PULL BO%E5, AFTER FABRICATION. UTILIZE HOT �IPPE� GALVAWZE� OR �IPPED M ZMC BASE� PRIMER FOR: OUTLET BOXES, JUNCTION BOXES. CONDOIT HANGERS, RODS, INSERTS AN� SUPPORTS. ZINC BASED PRIMER OF STEEL EpUIPMENT AND RACEWAVS. A FIELO APPLIE� ZMC BASEO PRIME COAT SHALL BE UTILIZE� FOR STEEL OR IRONWORK. H. BRUSHAN�CLEANWORKPRIORTOCONCEALING,PAINTINGANDACCEPTANCEPAINTE�EXPOSE�WORK SOILE� OR �AMAGED', CLEAN AN� REPAIR TO MATCH ADJOINING WORN BEFORE FINAL ACCEPTANCE. REMOVE OEBRIS FROM INSIDE ANO OUTSIOE OF MATERIAL AN� EQUIPMENT. I. FINALLOCATIONSAN�MOUNTINGORIENTATIONSOFALLSWITCHES.RECEPTACLESANDLIGHTWMINAIRES FYAII\-1aVa:�I�la�Ppl11:I9dN:I11iN� 11�911{NNSY.Y�PItl:iPINAI[tl�6YN:L11�8iY911�M19q�lY%9:LN:IIISN�J:![tl:iPl@FYLIICV P]J 6. LOW-VOLTAGE DISTRIBUTION EQUIPMENT: A. PROVIDECOMPLETEEpUIPMENTINCWDING�.SWITCHES,FUSE$CIRWITBREAKERS.PANELSAND TRANSFORMERS. B. ALLEpUIPMENTSHALLCONFORMTONEMA,AN51,lEEESTANDARDSANDBUIL�INGSTANDARDS. C. �ISCONNECTSWITCHESSHALLBEFUSE�ORNONFUSEDASNOTE�ANDHORSEPOWERRATEDFORMOTOR LOADS. TOGGLE TYPE SWITCHES SHALL BE NONFUSE�. LOA� BRFAN, HAVING MAXIMUM RATINGS OF 20 AMP AT 600 VOLTS AND 30 AMP AT 240 VOLTS. TWO-POLE SWITCHES SHALL BE LEVITON MO�EL SIMILAR TO HART AN� HEGEMAN N0. ]810F. KNIFE-BLA�E TVPE SWITCHES SHALL BE LOA� BREAK, pUICK-MAKE-pUICK�BREAK, UL CLASS R UP TO 600 AMP MA%IMUM RATING EXCEPT AS NOTED �FA� FRONT, NEMA TVPE 1. E%CEPT AS NOTE�. D. FOSES'.1�CIRCUIT6�iTO6000AMPERE55HALLBEPROTECTEDBYFU5E551MILARTOCURREMLIMITING BUSSMANN LOW-PEAK iIME-DELAY FUSES KRP�C (AMP�SP, CLASS L LISTE� BV UL WITH AN INTERRUPTING RATWG OF 300,000 AMPERES RMS SYMMETRICAL 2) CIRCUITS 0 TO 600 AMPERES SHALL BE PROTECTE� BY FOSES SIMILAR TO W RREM LIMRING BUSSMAN LOW-PEAK DUALELEMENT TIME-0ELAV LPN-RK (AMP)SP (250V�1LPSRK (AMP)SP (60�V) OR LPJ (AMP�SP (600V) (ULCLASS RKi OR GLASS J). AND BE LISTED BY UL WITH AN INTERRUPiING RATING OF 300,000 AMPERES RMS SYMMETRICAL 3) MOTOR CIRCUITS - ALL INDNI�UAL MOTOR CIRCUITS WITH FULL LOAD AMPERE RATINGS (FLA) OF 48� AMPERES OR LESS SHALL BE PROTECTE� BV FUSES SIMILAR TO CURREM LIMITING BOSSMANN LOW-PEAK �UALELEMENT TIME-DELAY LPN-RK (AMP)SP (250V) /LPS�RK (AMP�SP (600V) OR LPJ (AMP�SP (600V) (ULCLASS RKi OR CLASS J). AND BE LISTE� BV UL WITH AN INTERRUPTING RATING OF 30q�00 AMPERES RMS SYMMETRICAL 4) ALL FUSES SHALL BE PROVI�E� BY SAME MANUFACTURER. 5) PROVI�E 1 SPARE MATCHING FIISE FOR EACH SET OF 3. E. CIRCUITBREAKERS'.MOL�E�CASEBREAKERSSHALLBETHERMALMAGNETIGpUICK�MAKE-pUICK-BREAK. BOLT-ON TYPE, MANUALLY OPERATE� WITH INSULATE� TRIP-FREE HAN�LE. MULTI-POLE TYPE BREAKERS SHALL CONTAIN INTERNAL TRIP BAR. TERMINALS SHALL BE SUITABLE FOR COPPER OR AW MINUM CABLE. FORNISH AU%ILIARY �EVICES WHERE REQUIRE�. ENCLOSURES SHALL BE DEAD FRONT. NEMA TYPE 1, E%CEPT AS NOTE�. FRAMES, IC AN� INTERCHANGEABLE TRIPS SHALL BE AS PoLLOWS. UNLESS OTHERWISE NOTE�:1)120 VOLTS, ID��AMP FRAME'.10,000 AMP5.1 POLE 2) 240 VOLT5.100-AMP FRAME:18 000 AMPS, 2 AN�3POLE5. F. �ISTRIBOTIONPANELS:SWITCHINGUNITSSHALLBE3PHASE,4WIRECIRCUR�BREAKERTVPEONLE55 OTHERWISE NOTED ON PANEL SCHEDULES. BUS BARS SHALL BE HAR� �RAWN COPPER, MINIMUM 98 PERCENT CON�UCTIVIN, SILVER OR TIN-PLATE� JOINTS. CABINETS SHALL BE WELDE� CORNERS. HARDWARE SHALL 8E CHROME-PLAiED WITH F W SH LOCKILATCH HANDLE ASSEMBLV (UP T0481N. HIGH DOORS) OR VAULT HANDLE LOCK AN� 3-POINT CATCH (LARGER THAN 481N. HIGH DOORS�. HINGES SHALL BE SEMLCONCEALE�.S-KNUCKLE STEEL WITH NONFERROUS PINS, 180-0EG OPENING. LOCATED A MA%IMUM 26 W. ON CENTERS. MINIMUM GUTTER SPACES FOR LIGHTING PANELS SHALL BE 5314IN. SI�ES, PLASTIC, TRANSPARENT COVER. A TYPEWRITTEN LIST IN�ICATWG FEEDER CABLE AN� CONDUIT SIZE. CIRCUR NUMBERS, OUTLETS SUPPLIED AND THEIR LOCATIONS SHALL BE PROVIDED. G. BAIANCETHELOA�OVERPHASESWHENNEWCIRCUITSAREADDE�TOPANELS.PROVI�EMULTLCABLE W GS WHERE REpUIRED. �OUBLE W GGING SHALL NOT BE PERMITTED. MOl1NTING HEIGHT SHALL BE A MAXIMUM OF 6 FT�61N. FROM FLOOR TO TOP SWITCH UNR. UP�ATE DIRECTORIES ON E%ISTING PANELBOAR�S WHERE CIRCUITING IS CHANGED. H. TESTS:OPENANDCLOSELOA�BREAKSWITCHWGDEVICESUNDERLOA�. 7.RACEWAYS: A. PROVIDERACEWAYSCOMPLETEWITHBOXESFITTINGSAN�ACCESSORIES.CONDUITOR TUBWG 9ZES REFERRED TO IN SPEQFICATIONS AND ON DRAWINGS ARE NOMINAL �IAMETERS. 8. MATERIAL5:1)RACEWAVS�.a.RIGIDSTEELCON�UIT�.FULLWEIGHTPIPE,GALVAMZE�, THRFADED. b. ELECTROMETALLIC TUBING (EMT�'. THIN WALL PIPE, GALVAMZED, THREADLE55. c. FLEXIBLE STEEL CON�UIT: CONTINUOUS SWGLE STRIP. GALVAWZED. d. WIREWAYS: WIRE SHALL BE AS NOTED, MINIMUM N0. i6 GAUGE STEEL WITH GROUN� CONTINUITV. FINISH SHALL 8E BAKED ENAMEL. COVERS SHALL 8E SCREW-ON. e. SURFACE METAL RACEWAV�. SIZE AS NOTED. BASE 0 041N., COVERy'. MATERIAL SHALL BE STEEL. FINISH SHALL BE BAKE� ENAMEL. COVERS SHALL BE SCREW�ON. 2) FITTINGS AND ACCESSORIES: a. RIGI� STEEb. NONSPLIT. THREADED, STEEL OR MALLEABLE IRON. ZINC �IE CAST NOT PERMITTED. b. ELECTROMETALLIC TUBWG COMPRESSION TVPE. GALVAMZE� RIGID STEEL ELBOWS, Y OR LARGER. u FLE%IBLE METALLIC CONDUIT: ANGLE WE�GE TYPE WITH INSUTATED THROAT. d. BOSHINGS: METALLIC INSULATE� TYPE. 3) BOXES: a.OUTLET BO%E5: EXCEPT AS OTHERWISE REpUIRED BV CONSTRUCTION, �EVICES OR WIRING. BOXES SHALL BE STAMPED STEEL, 4" SQOARE OR OCTAGON FOR LUMINAIRES. BOXES ABOVE CEILING SHALL 8E �" �EEP. BO%ES IN CEILING OR SLAB SHALL BE 3" DEEP. BOXES IN WALL FOR W MINAIRES SHALL BE 2�" �EEP. BOXES IN WALL FOR RECEPTACLES AND SWITCHES SHALL BE 1y' DEEP. FURNISH WITH RAISED COVERS AND LUMINAIRE STUDS WHERE REpUIRED. WITHOUT LUMINAIRE OR �EVICE'. FURNISH BLANK COVER. OFFSET BACK-TO�BACK OUTLETS WITH MINIMUM 6" SEPARATION. b. JUNCTION AN� PULL BOXES: GALVAWZED SHEET STEEL WITH SCREW-ON COVERS, E%CEPT AS NOTE�. FURNISH WITH INSULATED SUPPORTS FOR CABLES LOCATIONS SHALL BE AS NOTE� OR REQUIRED AND ACCESSIBLE. FLOOR BO%ES SHALL BE SUITABLE FOR CONDUIT AND DEVICES NOTED. RAISE� OUTLETS SHALL BE HUBBELL dB2d16 SERIES WITH ABOVE FLOOR FITTING. TELEPHONE: BOSHED HOLE. POWER: �UPLE%RECEPTACLE OR OTHER AS NOTED. INCREASE SIZE TO SI11T AS NECESSARV. FLUSH OUTLETS SHALL BE HUBBELL %B2014 SERIES WITH FLUSH FLOOR FITTWG FOR TELEPHONE AND FLUSH DUAL FLAP COVER WITH DOPLE%RECEPTACLE FOR POWER AS NOTE�. WCREASE SIZE TO SUIT AS NECESSARV. C. PROVIDE RACEWAYS ONLV AS HEREIN SPECIFIE�. E%CEPT AS NOTED. RACEWAYS SHALL BE RON CONCEALE�, E%CEPT AS NOTE�. PROVIDE RACEWAY SUPPORT UTILIZING CEILING TRAPEZE, STRAP HANGERS, OR WALL BRACKETS. SECURE ALL RACEWAVS TO SUPPORTS WITH PIPE STRAPS OR U-BOLTS. SPACING OF SUPPORTS SHALL BE A MINIMUM OF 10' ON CENTER FOR METALLIC RACEWAY AN� AS REQUIRED FOR NONMETALLIC RACEWAV. SPACING SHALL BE 5' ON CENTER FOR WIREWAVS AND PER CO�E AN� AS NOTE� FOR OTHERS. MOUNT SUPPORTS TO STRUCTURE MASONRV WITH TOGGLE BOLTS ON HOLLOW MASONRV, EXPANSION SHIELDS OR INSERTS IN CONCRETEAN� BRICK. MACHINE SCREWS ON METAL, BEAM CLAMPS ON FRAMEWORK, WOOD SCREWS ON W00�, AND PAN THROUGH STRAPS IN METAL DECK. NAILS, RAWL P W GS OR WOOD P W GS SHALL NOT BE PERMITTED. WHERE REpUIRED BY STRUCTURE FURNISH THROUGH BOLTS AN� FISHPLATES. E%POSE� RACEWAVS SHALL BE RUN PARALLEL WRH OR AT RIGHT ANGLES TO WALLS. PROVIDE CLEARANCE WITH WATER STEAM OR OTHER PIPING MINIMUM 31N. SEPARATION FROM STEAM AN� HOT WATER ( PIPES, EXCEPT 1" FROM PIPE COVER AT CROSSINGS AND 18" FOR PARALLEL RUNS�. FOR HUNG CEILING OUTLETS. RUN IN HUNG CEILING AND CONNECT TO CEILING SUPPORT CHANNELS. IN MASONRV AND POURE� WNCRETE. RUN VERTICALLY ONLV. MAINTAIN GROONDING CONTINWTV OF INTERRUPTE� METALLIC RACEWAYS WITH GROUND CONDUCTOR, AND IN FLEXIBLE CONDUIT FOR FEE�ERS AN� MOiOR TERMINAL CONNECTIONS. EMPTV RACEWAVS OVER 1P LONG: PROVIDE FISH OR PULL WIRE GALVAWZED OR NVLON ROPE. RIGID STEEL CON�UIT SHALL BE PERMITTE� FOR FEEDERS AND BRANCH CIRCUITS. PAINT MALE THREADS OF FIELD�THREADED CONDUIT WITH GRAPHITE�BASE PIPE COMPOUND AND BUTT CONDUIT EN�S. TOUCH UP MARRE� SORFACES AND FIELD�CUT THREADS, CRGWL� GALVAMZED. EMT SHALL BE PERMITfED FOR BRANCH CIRCUITS ONLV, IN DRY LOCATIONS. �RV WALLS. HUNG CEILINGS, HOLLOW BLOCK WALLS AND FURRED SPACES. EMT SHALL NOT BE PERMITTE� IN RAISE� FLOORS. FLEXIBLE STEEL CON�UIT SHALL BE UTILIZED FOR SHORT CONNECTIONS WHERE RIGI� CONDUIT IS IMPRACTICAL. FROM OIITLET BOX TO RECESSE� LIGHTWG W MINAIRE: PROVIDE MINIMUM d' AN� MA%IMUM 6' LENGTHS. FOR FINAL CONNECTION TO MOTOR TERMINAL BOX, TRANSFORMER AN� OTHER VIBRATING EpUIPMENT'. PROVI�E WITH POLYVINYL SHEATHING AND GROUND CONDUCTOR. MINIMUM LENGTH'. 18" WITH SLACK. CONNECT GROUND CONDUCTOR TO ENCLOSURE OR RACEWAV AT EACH END. FOR EXPANSION JOINT CROSSMGS. CROSS AT RIGHT ANGLES AND ANCHOR ENDS. CUT CONDUIT ENDS SpUARE. REAM SMOOTH. PAINT MALE THREADS OF FIELD THREA�E� RACEWAYS WITH GRAPHITE BASE PIPE COMPOUND. DRAW UP TIGHT WITH RACEWAV COUPLING. EXPANSION FITTINGS SHALL BE INSTALLED AT RIGHT ANGLES WITH CLIP JOINT CENTERED IN EXPANSION JOINT. PROVIDE A LENGTH OF RUN IN ACCOR�ANCE MANUFACTURER'S RECOMMENDATIONS. PRESET FITTINGS SHALL ALLOW FOR TEMPERATURE VARIATION. RACEWAYS PASSING THROUGH FIRE�RATED CONSTRUCTION: SEAL OPENING WITH FIRE SEALANT. �. ERECTWALLANDSWITCHOUTLETSINADVANCEOFFURRINGAN�FIREPROOFING.OUTLET BO%ES SHALL BE SET SQUARE AND TRUE WITH BUILDING FINISH. SECURE TO BUIL�ING STRUCTURE 8Y ADJUSTABLE STRAP IRON OR GROUT IN WITH MASONRV. VERIFV OUTLET LOCATIONS IN FINISHE� SPACES WITH ARCHITECTIIRAL DRAWINGS OF INTERIOR DETAILS AND FINISHES. PROVIDE BARRIERS BETWEEN SWITCHES CONNECTE� TO DIFFERENT PHASES FOR VOLTAGES EXCEEDING 150 VOLTS TO GROUND. E. PANEL,JUNCTIONANDPOLL80%ESSHALLBELOCATEDCLEAROFOTHERTRADES.CONCEAL JUNCTION AN� PULL 80%ES IN FINISHE� SPACES. WHERE NECESSARV, REROUTE RACEWAVS OR MAKE OTHER ARRANGEMENTS FOR CONCEALMENT. BOXES SHALL BE ACCESSIBLE. SUPPORT BO%ES FROM BUILDING STRUCTURE, IN�EPENDENT OF CON�UR. PROVIDE FLOOR�TO�CEILING CHANNELS FOR MOONTWG ON �RVWALL AND LIGHTWEIGHT CONSTRUCTION. OUTLET BO%ES FOR LUMINAIRES RECESSED IN HUNG CEILINGS SHALL BE ACCESSIBLE THROUGH OPENING CREATED BV REMOVAL OF W MINAIRE. SECURE TO BLACK IRON SIIPPORT. MOTOR TERMINAL BOXES'. COORDINATE WITH MOTOR BRANCH CIRCUIi CON�OIT AN� WIRING: ADD BOX VOW ME WHERE REQOIRED. F. FIRESEALANTS:PROVIDEFORRACEWAVSANDWIREPASSINGTHROUGHFLOORSLOTS, SLEEVES OR OPENINGS IN FIRE-PARTITIONS ROOMS. G. PERFORMCONTINUITVTESTSOFRESISTANCEOFFEEDERCON�UITSFROMSERVICETO POINT OF FINAL DISTRIBUTION USING 1 CONDUCTOR RETURN. MA%IMUM RESISTANCE SHALL BE250HM5 H_ METALCLA�CABLE(TVPEMCJWITHGROUN�WIREMUSTCOMPLYWITHNEMAWCIO/ICEA 5-95-658. MC CABLE IS ACCEPTABLE FOR BRANCH CIRCUITS THAT ARE CONCEALED WITHIN CEILINGS, WALL PARTITIONS.OR FLOORS. INSTALL E%POSED CABLES PARALLEL AND PERPENDICULAR TO SURFACES OF EXPOSED STROCTURAL MEMBERS AN� PoLLOW SIIRFACE CONTOURSWHEREPOSSBLE. 8. WIRE AND CABLE: A. PROVIDEWIREANDCABLECOMPLETEWITHACCESSORIES.SIZEREFERENCESHALLBEAWG E%CEPT AS NOTE�. B. CONDUCTORSSHALLBECOPPER,ASTMSTANDARDSOLID�N0.10ANDSMALLER)OR STRANDED (N0.8 AN� LARGER). GENERAL USE CABLING SHALL BE N0. 12 MINIMUM. AT 12� VOLTS AND OVER 100' CIRCUIT LENGTH PROVIDE N0.10 MINIMOM. AT 265 VOLTS AND OVER 200' CIRW IT LENGTH PROVIDE N0.10 MINIMIIM. CONTROL AND ALARA4 CABLING. E%CEPT AS NOTED. SHALL BE N0. 1A MINIMUM. AT 120 VOLTS AN� OVER 200' CIRCUIT LENGTH PROVIDE N0. 8 MINIMUM. OTHER VOLTAGES AN� PHASES: ADJUST CABLE SILNG AS REQUIRE� TO MAINTAIN VOLTAGE DROP. INCREASE RACEWAV SIZES FOR LARGER WIRE AS REpUIRED. C. INSULATION SHALL 8E RU86ER AND THERMOPLASTIC MEETING ASTM AND IPCEA STANDAR�S. TVPE THW OR THWN SHALL BE OTILIZED FOR FEEDERS AN� BRANCH CIRCOIiS E%CEPT AS NOTED. TVPE SFF2 SHALL BE UTILIZED FOR BRANCH CIRCWTS LOCATE� IN WIRWG CHANNELS OF CONTINUOUS F W ORESCEM W MINAIRES AN� IN AM1IBIENT TEMPERATl1RE5 OVER 90 DEG G FOR UNGROUNDED ISOLATED BRANCH CIRCOITS PROVIDE CRO55-LINKED POLVETHYLENE INSULATION (NPE XHHW). D. COLORCODINGSHALLBEASFOLLOW5:1�120p08VOLT5V5TEM-BLACKFORAPHASERE� FOR B PHASE BLUE FOR C PHASE 2) NEUTRAL WIRE SHALL UTILIZE 4NHITE OUTER COVERING THROUGHOUT. EQUIPMENT GROON� WIRE SHALL UTILIZE GREEN OUTER COVERING THROUGHOUT. WHERE WLOR-CODED CABLE IS NOT AVAILABLE, CERTIFY IN WRITWG AND REQUEST PERMISSION TO OVERLAP CONDUCTORS WITH 6" OF COLOR TAPING IN ACCESSIBLE LOCATIONS. E. PROVIDEFLAMEPROOFLINENORFIBERTAGSINACCESSIBLELOCATIONS.FORFEEDERS INDICATE FEE�ER NOMBER, SIZE, PHASE AN� POINTS OF ORIGIN AND TERMINAilONS. FOR CONTROL AND ALARM WIRING IN�ICATE TYPE (CONTROL OR ALARM). SIZE OF WIRE. AND POINTS OF ORIGIN AND TERMINATIONS. 8. WIRE AND CABLE: (CONTINUED) F. TERMINATIONS,SPLICESANDTAPSUN�ER600VOLTS:COPPERCONDUCTORSN0.10AN� SMALLER SHALL UTILIZE COMPRESSION-TVPE OF TWIST-ON SPRINGLOADED CONNECTORS AND CLEAR NYLON-INSULATE� COVERING. COPPER CON�UCTORS N0. 8 AND LARGER SHALL UTILIZE MECHANICAL BOLTED PRESSURE OR HYDRAULIC COMPRESSION TVPE USWG MANUFACTURER'S RECOMMEN�ED TOOLING. CABLE LUGS AND CONNECTORS SHALL UTILIZE COMPRESSION TVPE OF SAME METAL AS CONDUCTOR. PROVI�E TO MATCH CABLE, WITH MARKWG INDICATING SIZE AND TVPE. COPPER W G CONNECTIONS TO BUS BARS'. USE ANTISEIZE COMPOUND ON TANG. G. NOTMORETHAN3LIGHTINGORCONVENIENCEOUTLETCIRCUITSSHALLBEINSTALLEDINONE CONDUIT UNLE55 OTHERWISE IN�ICATED. PULL NO THERMOPLASTIC WIRES AT TEMPERATlIRES LOWER THAN 32 DEG F. PROVI�E SEPARATE RACEWAYS FOR CON�OCTORS OF 1201208 AND 265/d60 VOLT SVSTEMS, E%CEPT 660 VOLT MOTOR BRANCH CIRCUIT WIRWG AND RELATE� 120 VOLT CONTROL WIRING. THERMOPLASTIC WIRES SHALL NOT BE INSTALLE� IN COMPUTER AREA RAISED FLOORS. H. LEAVEWIRESWITHSUFFICIENTSLACKTOPERMITMAKINGFINALCONNECTIONS. I. PERFORM CONTINUITVAN� INSULATION TESTS. MEGGER TEST 100 PERCENT OF FEEDERS.10 PERCENT OF BRANCH CIRW ITS AND ALL MOTOR BRANCH CIRCUITS OVER 25 HP. PERFORM TESTS PRIOR TO CONNECTING EpUIPMENT AND IN PRESENCE OF AUTHORIZED REPRESENTATIVES. SUBMIT WRITTEN REPORT OF RESULTS. CORRECT OR REPLACE CABLE TESTING BELOW MANUFACTURER'S STANDARDS. J. TVPENMCABLEISACCEPTABLEINACCORDANCEWITHTHENEGNECARTICLE511�OESNOT APPLY DUE TO NO PATIENT CARE AREAS ON THE PROJECT. 9. DEVICES: A. PROVI�ECOMPLETEMATERIALANDACCESSORIESASPERBUIL�INGSTANDARDS. B. LOCAL WALL SWITCHES SHALL BE SPEGFlCATION GRADE, T06GLE. QUIET iVPE RATED 20 AMP,12�21] VOLT, AG LEVITON MODEL SIMILAR TO HUBBELL NOS. 122� (SINGLE POLE�, 1222 (�OUBLE POLEJ.1223 (3WA1� AND 1224 (4WAV1. C. INSERTION RECEPTA0.ES SHALL BE SPEqFICATION 6RA�E �UPLEX CONVEMENCE 125 VOLTS, 2 POLE, 3 WIRE, U GROUND SLOT. GROUNDEq EXCEPTAS NOTE�. MEETING NEMA STANDARDS. PUBLICATION WD-1-09]i. LEVITON MODEL SIMILAR TO HUBBELL NOS 53fi2 (20 AM� AND 5262 (15 AMPJ. �) SIN6LE, EXCEPT AS NOTE�: e. 20 AMP STRAIGHT BLADE, SIMILAk TO HUBBELL NQ 53fi1. b.125 VOLT, 2 POLE, 3 WIRE, 6ROUNDED.2) SPECIAL USP. NONIMERCHANGEABLETYPESAN�RATINGS.3)GROUNDFAULTIMERRUPTER RECEPTAQES'. a FEE�-THRU NPE LEVITON MODEL SIMILAR TO HUBBELL NOS. GF5362 (20 AM� AND 6F5282 (�5 AMP). D. MOMENTARVCONTACTSWITCHESFORREMOTECONTROLSWITCHES,LEVITONMODEL SIMILAR TO HUBBELL N0. 4354. E PILOTLI6HTS:NEONLAMP,LEVITONMODELSIMILARTOHUBBELLNO.T1315,WITH125VOLT LAMP. F DEVICEPLATES'.SEEARCHITECTFORNPEFORRECEPTA0.ESWITHOTHERTHAN120VOLT, INSCRBE� VOLTAGE AVAILABLE. G. WLORS:WORDINATECOLORSWITHARCHITECT. H. MOUNTIN60RIENTATIONOFRECEPTAQES�VERTICAL):COORDINATEWITHARCHITECT. L RlI5HFL00RM0UNTE�POKETHR0UGH0URETPOKETHROUGHFL00RRTTINGWITH2 HOUR FlRE RATING. MOUNTS 4' �IAMETER HOLE PAINTABLE DIE CAST ALUMINUM CARPET FLAN6E PROVIDE MODIRE� LEXAN SLIDE HOLDER TO SIIPPORT A QUA� ELECTRICAL OUTLET. COMPLETE WITH ALL NECESSARV HAR�WARE FOR COMPLETE INSTALLATION. SIMILAR TO WIREMOL� PARTNO. RC-0. 10. LUMINAIRES: A. PROVIDELUMINAIRESCOMPONENTSANOLAMPS.LUMINAIRESSHALLBECOMPLETELV FACTORV ASSEMBLED. WIRE� ANO E�UIPPED WITH ALL NECESSARV SOCKETS, BALLASTS, SUPPORTING HARDWARE AND ACCESSORIES. REFER TO ARCHITECTURAL DRAWINGS FOR INDIVIDUAL LUMINAIRE DESCRIPTIONS. B. LUMINAIRECATALOGNUMBERSUSEDTOILLUSTRATEEQUIPMENTTVPEDONOTNECESSARILV DENOTE RE�UIREO MOUNTING EQUIPMENT OR ACCESSOPoES. PROVI�E ACCESSORIES TO SUIT. G BALLAST�.CLASSP,HIGHPOWERFACTOR,LOWESTAVAILA&ENEMARATE�NOISELEVELETt AND CBM APPROVE�. ENERGY SAVING iVPE TRIGGER START FOR 2a-INCH LAMPS AND RAPID START PoR 48-INCH. TWO LAMP BALLASTS; NO THREE LAMP BALLASTS. BALLASTS SHALL BE ADVANCE MAGNETEK. UNIVERSAL OR EQUAL. 11. TELEPHONE AND SECURITY CONDUIT SYSTEM: A. PROVIDECOMPLETESVSTEMOF:EMPTYCONDUIT,PULLBOXES.OIITLETS.SLEEVESAN� FISHWIRES. B. OUTLETS SHALL BE 1) WALL: a" S�UARE WITH BUSHEO COVER PLATE.2) FLOOR: CAST IRON WITH LOW TENSION FITTING. C. PROVIDEFISHWIRES,INRACEWAVSOVERIPLONG. D. CONDUITSHALLBE%'MINIMUM.PROVIDEEMPTYWNDUITFROMOIITLETTONEAREST ACCESSIBLE HUNG CEILING. � R _ ] 207 4TEOF ;'� W� � � A NP.G2�� � N A L Ea p���� p=c.,..,,s....�� os� u � a� a� � "� � � U7 O o � ��� a U � � � � C � p � � � � �- N � O W - N `" co � N O U �N � •L � U � 6 N n\ N W = L � � U � < �n` W\ / Q �,»��»�ii�id Aveda Institute 16281 Tri Ridge Blvd Suite 140 Loveland, Ohio 45140 SHEET WFORMATION Prolect p: 20013 Issoed Fort BID / PERMIi Dafe: 5/29/20 Revkions'. � PEServices ENGINEERING FOH VOUR 5U[[E55 1-513-836-3810 vwuw. pe-servi�es.com �.y:ieamne IT IS THE RESPONSIBILITY OF THE W NTRACTOR TO NOTIFY THE ARCHITECT, LAN�LORD AND TENANT OF ANY °'S�REP""�'ESE"°°°"TERE°°"T"E"""S°R'" ELECTRICAL SPECS EXISTING SITE CONDITIONS PRIOR TO SUBMISSION OF BID. RELEA5E0 FOR CONSTRUCTION Suhjec� �o compliance with all regula�ions 04 S�a�e antl Local Codes City of Carmel `�y,:a���'.�`� �,�:;vaYa/„1��. DATE: O��0��20 BIDDERS ARE TO VISIT THE SITE AND FAMILIARRE THEMSELVES WITH EXISTWG CONDITIONS AND SATISFY THEMSELVES AS TO THE NATURE AN� SCOPE OF THE WORK. THE BASE BID SHALL REFLECT MODIFICATIONS TO SYSTEMS AND DEVICES AS REQUIRED BV STATE, LOCAL AND FEDERAL CO�ES WHETHER IN�ICATED OR NOT ON CONTRACT DOCUMENTS. THE SUBMISSIONS OF A BID WILL BE EVIDENCE THAT SUCH AN EXAMINATION AN� COMPLIANCE WITH GOVERNING CODESIREQUIREMENTS HAS BEEN MADE LATER CLAIMS FOR LABOR, E�UIPMENT, OR MATERIALS RE�UIRED, OR PoR DIFFlCULTIES ENCOl1MERED WHICH COULD HAVE BEEN FORESEEN HA� AN E%AMINATION AN� CODNREQUIREMENTS REVIEW BEEN MADE, WILL NOT BE ALLOWED. FYiIqi�RqJil:7q 7 E0.02