Loading...
HomeMy WebLinkAboutM0.01-Mechanical Cover SheetMECHANICAL SYMBOL LEGEND NOTES'. 7. ALL SYMBOLS MAY NOT APPLY. X-ZZZ DIFFUSERTYPFAIRFLOW(CFM) XX �ETAIL# REFERENCETAG !uB GRILLES2E gy,% SHEET# XX E�UIPMENTDESIGNATION XX CO�EDPLANNOTE � POINTOFCONNECTION O THERMOSTAT O HUMIDISTAT O REMOTE SENSOR O CO2SENSOR CO COSENSOR � RECTANGULARSUPPLVOUCTRISER �p Dl1CTM0UNTEDSMOKEDETECTOR � RECTANGULAR RETURN DUCT RISER � ROUN� SUPPLY �UCT RISER � RECTANGULAR EXHAUST DUCT RISER � ROUND RETURN DUCT RISER � 90 DEGREE TURNING VANE � ROUND EXHAUST DUCT RISER � RECTANGULAR DUCTTRANSITION � 45 DEGREE TURNING VANE —�� DIRECTION OF AIR FLOW `� ROUN� �UCTTRNNSITION FD� VERTICALFIREDAMPER Fp� FIREOAMPER VD 4�..w. VOLUME OAMPER WITH BLA�ES �p � VOLUME DAMPER g� SMOKE DAMPER F�S � FIRE SMOKE DAMPER Fl5� VERTICALFIRESMOKEDAMPER � MOTORIZEDDAMPER � CEILMG RADIATION DAMPER � SUPPLVAIRDIFFUSER � RETURNAIRGRILLE/REGISTER � EXHAUSTAIRGRILLEBEGISTER SINGLE LINE DUCTWORK NEW Dl1CTWORK E%ISTING Dl1CiVJORKTO BEREMOVED � RECTANGULAR RAOIUS RECTANGULAR ELBOW ELBOW � WITHTURNINGVANES � ROUNDRADWSELBOW � 90DEGREESUPPLVAIR � ELBOW UP/DOWN � 90 DEGREE RETURN AIR � 90 DEGREE EXHAUSTAIR ELBOW UP/DOWN �J ELBOW 11P/�OWN � 90DEGREEROUNDDUCT � SHAPETRANSITION � UP/DOWN � SIZETRANSITION �/�� FLE%IBLEDUCTTAP TEE WITH SQUARE ROUND DUCT TAKEOFF JL ELBOWS,TURNINGVANES, � WRHDAMPER AND SPLITTER DAMPER T RECTANGULAR DUCT I BEVELED TAP DOUBLE LINE DUCTWORK � NEW Dl1CTWORK _ EXISTING Dl1CTVJORKTO BEREMOVED � RECTANGULAR RADIUS � RECTANGULAR ELBOW ELBOW WITH TURNING VANES � ROUNDRADWSELBOW � 90DEGREESUPPLVAIR ELBOW UP/DOWN � 90 DEGREE RETURN AIR � 90 DEGREE EXHAUSTAIR ELBOW UP/DOWN ELBOW 11P/�OWN LJ�X 90�EGREEROUND�UCT � SHAPETRANSITION UP/DOWN � SIZE TRANSITION � FLEXIBLE DUCT TAP � TEE WITH SQUARE � ROUN� OUCT TAKEOFF ELBOWS, Tl1RNING VANES, WRH �AMPER AND SPLITTER DAMPER � RECTANGULAR �UCT BEVELED TAP MECHANICAL NOTATIONS AC AIRCON�RIONING EL ELEVATION MIN MINIMl1M ACCU AIRCOOLEDCONDENSINGUNIT ELEC ELECTRIC(AL) MISC MISCELLANEOUS ACU AIR CONDITIONING UNIT ELEV ELEVATOR MPR MEDIUM PRESSURE STEAM RETURN AFF ABOVE FINISHED FLOOR EM EMERGENCV MPS MEDIUM PRESSURE STFAM SUPPLY AFG ABOVEFINISHEDGRADE ERU-# ENERGYRECOVERYUNIT NO/# NUMBER AHII AIRHANDLINGUNIT EQUIP EQUIPMENT MS NOTTOSCALE ALT ALTERNATNE ETR EXISTINGTOREMAIN OA Ol1TSIDEAIR AMB AMBIENT EUH-# ELECTRICUNITHEATER OAU OUTSIDEAIRUNIT AP ACCE55 PANEL EXH EXHAUST OC ON CENTER APPRO APPROXIMATE EXIST/E EXISTING OD OUTSIDEDIAMETER ARCH ARCHITECT(URAL) EXP EXPLOSIONPROOF PC PLUMBINGCONTRACTOR ARV AIRRELIEFVAWE E%T EXTERIOR PSI POUN�SPERS�UAREINCH ATV AIRTURNINGVANE F-# FURNACE PVC POLVVINYLCHLORI�E AUTO AUTOMATIC FC-# FAN COIL UNR R RA�IUS B-# BOILER FD FIREDAMPER RA RETURNAIR BD BAROMETRICDAMPER FEV FLUEEXHAUSTVENT RG-tt RETURNAIRGRILLE BDD BACKDRAFTDAMPER FLR FLOOR REQ'D REQUIRED BHP BRAKEHORSEPOWER FPM FEETPERMINUTE RL REFRIGERANTLIQUID BOP BOTTOM OF PIPE FlS COMBINATION FIRE/SMOKE OAMPER RM ROOM BLDG BUILDMG FS1! FlLTRATIONSVSTEM RPM REVOLUTIONSPERMINl1TE CAB CABMET FSC FIRESUPPRESSIONCONTRACTOR S SMONEDAMPER CD�# CEILINGDIFFUSER FT FEET SN SUPPLVAIR CIA COMBUSTIONINTNKEAIR GN GAUGE SD�# SUPPLYAIRDIFFUSER CFM CUBICFEETPERMINUTE GALV GALVANIZE(D) SG-p Sl1PPLYAIRGRILLE CHP CHILLEDWATERPUMP GAL GALLON SP STATICPRESSURE CHWR CHILLEDWATERRETl1RN GC GENERALCONTRACTOR SPEC(S SPECIRCATION(5) CHWS CHILLEDWATERSUPPLY GPM GALLONSPERMINUTE STD STANDARD CL CENTERLINE H HEIGHTIHIGH SUC SITEUTILITYCONTRACTOR CLG CEILING HC HVACCONTRACTOR TEMP TEMPERATURE COL COWMN HP HORSEPOWER TVP TYPICAL CON� CON�ENSATE HPR HIGH PRESSURE STEAM RETURN UH-7! UNR HEATER CPSR COMPRESSOR HPS HIGH PRESSURE STEAM SUPPLY UNO UNLESS NOTED OTHERWISE CT# COOLINGTOWER HSW HIGHSIDEWALL UV UNINENTILATOR CUH-# CABINETUNITHEATER HVAC HEATING/VENTING/AIRCONDITIONING V VENT CWP CONDENSERWATERPUMP HWP HOTWATERPUMP VAV VARIABLEAIRVOLUME CWR CONDENSERWATERRETURN HWR HOTWATERRETURN VD VOLUMEDAMPER CWS CONDENSERWATERSUPPLY HWS HOTWATERSUPPLV VEL VELOCIN D DEPTH / �EEP I� INSIDE �IAMETER VFD VARIABLE FREQUENCY DRNE DB DRYBULBTEMPERATURE INSUI INSULATION/INSULATE VIF VERIFYMFlELD DCW DOMESTICCOLDWATER KW KILOWATTS VTR VENTTHROUGHROOF DHW DOMESTIC HOT WATER L LENGTH / LONG VVB VARIABLE VOLUME BOx OIA/0 DIAMETER LPR LOWPRESSURESTEAMRETURN WF VARIABLEVOWMEFANPOWERE� �IFF DIFFUSER LPS LOWPRESSURESTEAMSl1PPLY VVR VARIABLEVOWMEREHEAT DISCH �ISCHARGE LSW LOWSI�EWALL W WI�THIWIDE DWG DRAWING LVR LOUVER W/ WITH E EXISTING M METER W/0 WITHOUT EC ELECTRICALCONTRACTOR MAx MAxIMUM WB WETBULBTEMPERATURE EF-f! EXHAUSTFAN MC MECHANICALCONTRACTOR WCC WATERCOOLEDCHILLER EFF EFFICIENCY MECH MECHANICAL WH-1t WATERHEATER EG-# EXHAUSTGRILLE MFR MANl1FACTl1RER MECHANICAL LINETYPE LEGEND GENERALOEMO GENERAL EXISTING CHR CHILLED WATER RETURN CHS CHILLED WATER SUPPLY CA COMPRESSEDAIR CD CONDENSATEDRAIN CWR CONDENSER WATER RETURN CWS CON�ENSERWATERSUPPLY HWR HOT WATER HYDRONIC RETURN HWS HOT WATER HYDRONIC SUPPLV LPC LOW PRESSURE CONDENSATE LPS LOW PRESSURE STEAM MPC MEDIUM PRESSURE CONDENSATE MPS MEDIUM PRESSURE STEAM N NITROGEN N20 NITROl1S 02 OXYGEN RL REFRIGERANTLI�UID RS REFRIGERANT SUCTION VAC VACUUM ALL OTHER LINETYPES DENOTED WITH: (AB) = ABANDONED', (D) = DEMO; (E) = EXISTING DELEGATED DESIGN ITEMS 1. STRUCTURALDESIGNFORALLITEMSRELATEDTOHVACE�UIPMENTSHALLFALLUNDERTHERESPONSIBILITYOFTHE HVACCONTRACTOR. THECONTRACTORSHALLSECURETHESERVICESOFAPROFESSIONALSTRUCTl1RALENGMEER TO EVALUATE THE EXISTING ROOF STRUCTURE AN� PROVI�E SEALED �RAWMGS FOR ALL REMFORCING AS RELATE� TO ANY HVAC EQUIPMENT TO BE LOCATED ON OR SUPPORTED BY THE 1.G. D��ISS A�CHITfCTS, „� s�• WALHALLA tOAD COLUMEUS, OHIO �s�o: (61�� 106.)]l0 t R _ ��za� TEOF ;�,� �c'�NDIANP.��2J s � .. .. a� ��� %/i..s�o NAL E_.�P�� � o�, p� uLL� U � w } O � d } � � � N U �L �^l i �..L � � � �' N N m � N O � � in v U t O �� 6 Q � Q � C o � — � w � N � a� o N � � N U � � N C � L U N � PREPARED FOR Aveda Institute 16281 Tri Ridge Blvd Suite 140 Loveland, Ohio 45140 SHEET WFORMATION Project #: 20013 luoed Por. BID / PERMIT Dbfe: 5/29/20 Revisions'. � � PEServices ENGINEERING FOH YDUR 5l1CCE55 7-573-636-3870 www.pe-services.com SHEET TITLE IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO NOTIFV THEARCHITECT,LANDLOR�ANDTENANTOFANV MECHANICAL COVER �ISCREPANGES ENCOUMERED ON THE PLANS OR IN EXISTINGSITECONDITIONSPRIORTOSUBMISSIONOFBID. SHEET RELEA5E0 FOR CONSTRUCTION Suhjec� �o compliance with all regula�ions 04 S�a�e antl Local Codes City of Carmel `�y,:a���'.�`� �,�:;vaYa/„1��. DATE: O��0��20 BIDDERS ARE TO VISIT THE SITE AND FAMILIARIZE THEMSELVES WITH EXISTING CONDITIONS AND SATISFY THEMSELVES AS TO THE NATURE AND SCOPE OF THE WORK. THE BASE BID SHALL REFLECT MODIFICATIONS TO SYSTEMS AND DEVICES AS REDUIRED BV STATE, LOCAL AN� FEDERAL CO�ES WHETHER IN�ICATED OR NOT ON CONTRACT DOCUMENTS. THE SUBMISSIONS OF A BID WILL BE EVIDENCE THAT SUCH AN EXAMINATION AN� COMPLIANCE WITH GOVERNING CODESIREQUIREMENTS HAS BEEN MADE LATER CLAIMS FOR LABOR, EQUIPMENT, OR MATERIALS REQUIRED, OR FOR DIFFIWLTIES ENCOUNTERED WHICH COULD HAVE BEEN FORESEEN HA� AN EXAMINATION AND GO�E/REQUIREMENTS REVIEW BEEN MADE, WILL NOT BE ALLOWED. SHEET NUMBER M0.01