HomeMy WebLinkAboutM2.01-Mechanical Roof PlanPLANNOTES: GENERALNOTES:
1. ROUTECONDENSATETOSPLASHBLOCK. A. ALLMECHANICALWORKSHALLBEDONEPERTHESTATEMEGHANIGALGODENNDLOGAL
MECHANICALCODES.
2 HVAC CONTRACTOR TO INSTALL SMOKE DETECTOR IN RBl1RN AIR DUCT.
B. MECHANICALCONTRACTORSHALLHOLDALLDUCTWORNASTIGHTASPOSSIBLETO
3. TERMINATEEXHAUSTATGOOSENECKWITHBIRDSCREEN. UNDERSIDEOFSTRUCTURE.
4. ROUTEMANUFACTURER'SREGOMMEN�EDFWEKITFORGASFIREDUNITHEATER C. MECHANICALCONTRACTORSHALLCOORDINATEDUCTROUTINGWITHLIGHTING.NO
THROUGH ROOF. PATCH ROOFAT E%ISTING FLUE PENETRATION TO BE PERFORME� DUCTWORK SHALL BE ROUTED OVER OR UNDER ANY LIGHT FIkTURES.
BY ROOFING CONTRACTOR.
D. ALLROOFTOPEQUIPMENTSHALLBEINSTALLEDAMINIMUMOFIO'-0"FROMEDGEOF
5. ROUTEVENTAN�FWEUPTHROUGHROOFTOMANUFACTURER'SRECOMMENDED ROOF.
VENT KIT.
E. TAB-TYPEFITfINGSWITHAIRSC00PS5HALLBEPROVIDE�FORALLROUN�BRANCH
6. EITHERPROVIDEADAPTINGCURBTOMATCHEXISTINGSIZEOFPENETRATIONOR TAPS.
REMOVE C11R6 AND PROVIDE NEW Cl1RB IF EXISTING 512E OF PENETRATION IS NOT OF
ADEQUATES¢E. F. FLEXCONNECTIONSTODIFFUSERSARETOBEINSULATEDFLEHWITHAMAXIMUM
LENGTH OF 5 FEET.
]. FlLL M EXISTING ROOF CURB. IT WILL NOT BE USED FORANV NEW E�l11PMENT.
G. MECHANICALCONTRACTORSHALLBERESPONSIBLEFORALLCONTROLWIRING.
H. MECHANICALCONTRACTORSHALLBERESPONSIBLEFORCOORDINATIONWITH
ELECTRICAL CONTRACTOR REGARDING THE WIRING OF ALL MECHANICAL EQUIPMENT.
I. PROVIDEBALANCEDAMPERSATALLBRANCH�UCTSSERVINGDIFFl1SERS.
J. DOORS SHALL NOT BE UNDERCUT IN EXCESS OF THE CLEARANCE PERMITTED IN
ACCORDANCE WITH NFPA-80.
K. PIPEANDDUCTSPASSINGTHRUHORIZONTALASSEMBLIESSHALLBEPROTECTEDWITH
AN APPROVED NON-COMBUSTIBLE MATERIAL TO RESIST THE FREE PASSAGE OF FLAME
AND THE PRO�UCTS OF COMBUSTION.
L HEATING E�IIIPMENT SHALL BE INSTALLED IN ACCOR�ANCE WITH UNDERWRRER'S
APPROVAL, MANUFACTURER'S RECOMMENDATIONS, GOOD ENGINEERING PRACTICE
AND THE STATE MECHANICAL CODE AND THE INTERNATIONAL FUEL GAS CODE.
M. CONTRACTOR SHALL COOR�INATE LOCATION OFAIR �EVICES WITH REFLECTED
CEILING PLAN AND LIGHTING LAYOUT.
N. ALLEXPOSEDDUCTWORKTOHAVEMILLPHOSPHATIZEDFINISHTOBEPAINTEDBLAGK
BY OTHERS.
1.G. D��ISS
A�C�iITfCTS, „�
a�• WALHALLA tOAD
COLUMEUS, OHIO �saoi
(bl�l ]064]]0
� � A NP.G�
NAL E�
,o� ��,.. ...Q� ,��
�
i
si
s�
si
�
�
U � U7 c+�
u' � � N O
� �
O N � �
� } C � �
� �� �
Q � C
_ O p
� w �
N �
N � o
N �
•L �NU
a
� �
^ N
� �
1�1 �
1� U
V L
�^
�
�
Q
PREPARED FOR
Aveda Institute
16281 Tri Ridge Blvd
Suife 140
Loveland, Ohio 45140
SHEET WFORMATION
Prolec� N: 20013
luoed Por. BID / PERMIT
Date: 5/29/20
Revisions'.
—
�
PEServices
ENGINEERING FOH YDUR 5l1CCE55
7-573-836-3810
www.pe-services.�om
6Y71qi�111�7
RELEA5E0 FOR CONSTRUCTION
Suhjec� �o compliance with all regula�ions
04 S�a�e antl Local Codes
City of Carmel
`�y,:a���'.�`� �,�:;vaYa/„1��.
DATE: O��0��20
IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO NOTIFY
THE ARCHITECT, LANDLORD AND TENANT OF ANY
�ISCREPANGES ENCOUMERED ON THE PLANS OR IN
EXISTING SITE CONDITIONS PRIOR TO SUBMISSION OF BID.
BIDDERS ARE TO VISIT THE SITE AND FAMILIARIZE
THEMSELVES WITH EXISTING CONDITIONS AND SATISFY
THEMSELVES AS TO THE NATURE AND SCOPE OF THE WORK.
THE BASE BID SHALL REFLECT MODIFIGATIONS TO SYSTEMS
AND DEVICES AS REQUIRED BV STATE, LOCAL AN� FEDERAL
CO�ES WHETHER IN�ICATED OR NOT ON CONTRACT
DOCUMENTS. THE SUBMISSIONS OF A BID WILL BE EVIDENCE
THAT SUCH AN EXAMINATION AND COMPLIANGE WITH
GOVERNING CODESIREQUIREMENTS HAS BEEN MADE LATER
CLAIMS FOR LABOR, EQUIPMENT, OR MATERIALS REQUIRED,
OR FOR DIFFICULTIES ENCOUNTERED WHICH COULD HAVE
BEEN FORESEEN HA� AN EXAMINATION AND
CO�E/REQUIREMENTS REVIEW BEEN MADE, WILL NOT BE
ALLOWED.
MECHANICAL ROOF
PLAN
tiy:i�anomaaa
M2.01