HomeMy WebLinkAboutM5.01-Mechanical DetailsRELEA5E0 FOR CONSTRUCTION Suhjec� �o compliance with all regula�ions 04 S�a�e antl Local Codes City of Carmel `�y,:a���'.�`� �,�:;vaYa/„1��. DATE: O��0��20 ROUTEDRYER EXHFUSTTHROUGH WALL. CONNECTION PoR DRVER 4"ID DRVER VENi SHALL BE A MINIMUM OF 26 GAUGE �2"METALRANGE �C. SEW RE TO WALL WITH DRYER VENT BOX BV DRYWALL SCREWS IN�O-VATE, UL RATE� " FOR 1 HOUR WALL, i � FLEXIBLE�RYERHO�� �� DETAILW-L7129 � BVOWNER. �� � � �DRVER I�I � -� �� I � � WASHER J � STANDALONE DRYERS SHALL BE PROVIDED BY TENANT NOTES'. 1. PROVI�E RATE� BOX WHEN INSTALLE� IN RATED WALL. 2. COORDINATE VENT BO%LOCATION WIDRVER OUTLET. POWER WIRING BV DIVISION 16- BIRD SCREEN SECURE FAN TO CURB WITH SCREWS OR LAGBOLTS COUNTER BALANCED BACK�RAFT �AMPER ORMOTORREDDAMPER AS SCHEOULED � 2" X 3/t6" FLAT BAR STRCH WEL�E� - 3116" THICK SLEEVE sEaRiTv oucT BARRIER.MOOELSDB BY iUTTLE AND BAILEY — EXHAOST �UCT, SEE PLANS FOR SIZE - SLIP CONNEGTIONS TO BARRIERMOOULE � POWER ROOF EXHAUST FAN DETAIL � 6 NTS M5.01 �ISCONNECTSWITCH 18' HIGH PREFABRICATED INSULATE� ROOF CURB BY HVACCONTRACTORTO FURNISH.GENERAL CONTRACTORTOINSTALL AN� FLASH AS PER ROOFING MANUFACTURER.CONSULT ROOFING MFR. FOR TVPE NOOD BLOCKING (BV GC ) i00FING MEMBRANE ROOF WSULATION 1-112 X 1-112 X 3/16 MIN. ANGLE FRAME STITGH WEL�E�TOSLEEVEAN� ROOFDECK �ATTACHE%HAUST�UCTTO CURB ]l8" RIBBE� TOOL RESISTANT STEEL BARS ON 5"CENTERS � 2V2 X 518" FLAT BAR ON 12" CEMERS WELDED TO SLEEVE � ROOF OPENING BY GG (SIZE VARIES. REFER TO DRAWING M4 0 FOR ROOF OPENING SRES AND COOR�INATE WITH STRUCTURAL DRAWINGS). NOTe VENT TAKEOFF DOWNSTREAM OF THE CONDESATE TRAP PER MANUFACTURER'S WSTALLATION SPECIFICATIONS. OPEN AIR CAP END PIPE �z" UNION �RAIN PIPING 9ZE TO MATCH UNIT DRAIN CONNECTION. PLUG OPTIONAL UNIT �RAINS WITH GALVNIZED PIPE PLUG. ROOF TOP UNIT CONDENSATETOCONCRETE SPLASH BLOCK,12'xt2" ON NEOPRENEPA� oannm a�uc 5 ROOFCURB TYPICAL CONDENSTATE DRAIN DETAIL 3 NTS M5.01 18'x18" � /2] 735° � �� � � Yn" HARDWARE CLOTH/GAWANEZED Iza.M�N COUNTER FLASHING SEAL AIR DUCT PLATE ROOF CURB INSTALLE� BV ROOFER � � `FLASHINGINSTALLED BV ROOFER MECHANICAL CONTRACTOR SHALL LOCATE ROOF CURB OPENWG FOR ROOFER. ROOFER SHALL OPEN ROOFING AND DECK AS RE�UIRED TO INSTALL CURB. ROOFER SHALL MSTALL CURB AN� FLASHING. MECHANICAL CONTRACTOR SHALL PROVI�E �UCT AND COUMER FLASHING ROOFER SHALL WARANTV ROOFlNG WORK. GOOSENECK DETAIL 8 N*5 M5.01 UCTMATE7ICL-00 :LUTCHER"WIREROPE � 4NGERSYSTEM.SPACE� OG. MA%IMUM FOR 'IRAL PIPE INSTALLE� IN 1'LENGTHS 4"BEXHAOSTVENTIIPTHRU WALLAN�INTOCEILING — STRUCTURETOE%HAUSTFAN. RTU RETURN AIR DUCT DETAIL � 9 NTS M5.01 MECHANICALCONTRACTORTOINSTALL2LAVERS OF1",3LB.�ENSIiVDUCTLINERBOAR� EALAIRTIGHT SANDWHICHED WITH 2 LAVERS OF ll2" GVP BOARD FACTORV FAeRICATED BETWEENDECKANDBOTTOMOFUNITWITHI BETWEENGYP CURBA�APTER�NP.) CURB CONFINES. BOAR� AN� INSI�E OF CURB. TYPICAL INSTALL3/A"RUBBERSEALBETWEEN ALLSI�ESAN�ALL �UCTFLANGEANDTOPOFCURB. LAYERS. O.A. H00� ALL SOORCES OF POLLUTION MUSTBE 10' HORIZONTAL DISTANCE AWAV ,� 16' za REF TO STORM� "P" TRAP W/ CLEANOUTS, "T" FITTINGS POWER WIRING INSTALL INSI�E OF UNIT CURB SUPPLY AIR DUCT. / PROVIDE 1-0/T' LINER J I ' /�/�� /�I , •• ' , . '.••. I��~� N�1: C. � � . . � ������ /I'� ' � � ._:!�!�A�I��Aii1�T!AISAE,�\ •�� � ' 4" �UCT DOWN IN WALL ELBOW HORIZONTALLV INTO THE HALF WALL TO SHEETMETAL BOX. MOUNT 6"%8" exnnusT sioewnu caiue �see ceiue scneou�e FORTYPICALE%HAUSTGRILLETAG)2"ABOVE - TABLETOP. COORDINATE EHACT HEIGHT WITH ARCHITECTURAL AND INTERIOR DESIGN DRAWINGS. A�TERNATE CADDRCLIP TVPE FASTENER TO BARJOIST WITH STRAP ELBOW TO HORIZONTAL THROUGHTO HALF-HEIGHT WALL � MANICURETABLE 12"RECTORSEAL BIGFOOT STAN� ROOFDECN� FINISHE� FLOOR HALFHEIGHT WALL MANICURE STATION EXHAUST 5 NTS M5.01 — WRAPAROUNDJOIST OR OTHER SUPPORT k85CREW5 —18GA MINIMUM STRAP. 1"WIDE,6'MA%IMUM HORIZONTALSPAQNG k8 SCREW AT TOP OF DUCT TURN STRAP UN�ERDUCTI" WITH %0 SCREW W-RIB SPIRAL �UCT, �,.��JIMUM 26GA WUIVALENT, GAUGEPERSMACNA CONSTRUCTION STANDARDS RIGID DUCT MOUNTING DETAIL 2 NTS M5.01 SEAL SPAGES BETINEEN ROOF �ECK AN� �UCTS AIRTIGHT. I I I � --- - �� I I � SMOKE �ETECTOR A I THERMOSTAT I^ - WHERERE�UIRED� __1J L��___ REFERENCE _ J WIRING - E�UIPMENT RETURN AIR DUCT. PROVIDE SCHEDULES. LINERAS SPECIFIED. <AGED ROOFTOP UNIT DETAIL � 7 NTs ��� n� CONDENSING un �OP I� GENERALNOTES' A. ALL MECHANICAL WORK SHALL BE �ONE PER THE STATE MECHANICAL CODE AND LOCAL MECHANICALCO�ES. B. MECHANICALCONTRACTORSHALLHOLDALL�UCTWORKASTIGHTASPOSSIBLETO UNDERSIDE OF STRUCTURE. G MECHANICALCONTRACTORSHALLCOOR�INATEDUCTROUTMGWITHLIGHTING.NO DUCIWORK SHALL BE ROUTED OVER OR UNDER ANY LIGHT FIXTURES. D. ALL ROOFTOP EQUIPMENT SHALL BE INSTALLED A MINIMUM OF 14'-0" FROM EDGE OF ROOF. E. TAB-NPEFITTMGSWITHAIRSCOOPSSHALLBEPROVIDEDFORALLROUNDBRANCH TAPS. F. FLEXCONNECTIONSTODIFFUSERSARETOBEINSULATEDFLE%WITHAMARIMUM LENGTH OF 5 FEET. G. MECHANICALCONTRACTORSHALLBERESPONSIBLEFORALLCONTROLWIRING. H. MECHANICALCONTRACTORSHALLBERESPONSIBLEFORCOORDINATIONWITH ELECTRICAL CONTRACTOR REGARDING THE WIRING OF ALL MECHANICAL EQUIPMENT. I. PROVIDE BALANCE DAMPERS ATALL BRANGH DUCTS SERVMG DIFFUSERS. J. DOORS SHALL NOT BE UNDERCUT IN EXCESS OF THE CLFARANCE PERMITfE� IN AGCORDANCE WITH NFPA-80. K. PIPE AND �UCTS PASSING THRU HORIZONTAL ASSEMBLIES SHALL BE PROTECTED WITH AN APPROVED NON-0OMBUSTIBLE MATERIAL TO RESIST THE FREE PASSAGE OF FLAME AND THE PRO�UCTS OF COMBUSTION. L HEATING E�UIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH UNDERWRITER'S APPROVAL, MANUFACTURER'S RECOMMENDATIONS, GOOD ENGINEERING PRACTICE AND THE STATE MECHANICAL CODE AND THE INTERNATIONAL FUEL GAS CODE. M. CONTRACTORSHALLCOOR�INATELOCATIONOFAIRDEVICESWITHREFLECTED CEILING PLAN AND LIGHTING L4YOUT. N. ALLEXPOSED�UCTWORKTOHAVEMILLPHOSPHATIZEOFINISHTOBEPAINTEDBLACK BY OTHERS. DISW NNECT (SEE ELECTRICAL DRAWINGS FOR INSTALLATION AND LOCATION) —36" CLEAR ACCESS � PROVIDE FIASHING AN� � � CAULK PENETRATION OFFSET REFRIGERANT LWE INSTALLATION SOTHATTHEVARENOTLOCATE� �IRECTLV BELOW THE DISCONNECT. J MINI SPLIT CONDENSING UNIT 4 NTS M5.01 W NNECT FLE% DUCT ENDS TO SHEET METAL DUCT AND DIFFUSER WITHNYLONTIES. WTERIORLINERANDEXTERIORINSIILATIONOF REXDUCTTOBETIEDINDIVIDUALLV. MSTALLUSINGTENSIONING TOOL AS PER MANUFACTURER'S RECOMMENDATIONS. PREINSULATE� FLE%IBLE �UCTWORK. SEE SPECIFICATIONS. LENGTHNOTTOEXCEEDS-0". PROVIDESUPPORTSMACNA STANDARDS.INSTALLFREEOFKINK585AG5. NVLON TIES INTERIOR LWER INSULATE� FLEX �UCT�MAX.5'-0' LENGTH) FLEX DUCT SIZE SHALL MATCH SUPPLV DIFFUSER NECK SIZE. REFER TO PLANS AND SPECIFICATIONS. CEILING- SEE ARCH. PLANS FOR TVPE TYPICAL DIFFUSER CONNECTION DETAIL � 1 NTS M5.01 � � PEServices ENGINEERING FOH YDUR 5l1CCE55 7-573-836-3810 VYW W.�]C-9eN�CC9.COR1 IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO NOTIFY THE ARCHITECT, LANDLORD AND TENANT OF ANY �ISCREPANGES ENCOUMERED ON THE PLANS OR IN EXISTING SITE CONDITIONS PRIOR TO SUBMISSION OF BID. BIDDERS ARE TO VISIT THE SITE AND FAMILIARIZE THEMSELVES WITH EXISTING CONDITIONS AND SATISFY THEMSELVES AS TO THE NATURE AND SCOPE OF THE WORK. THE BASE BID SHALL REFLECT MODIFICATIONS TO SYSTEMS AND DEVICES AS REQUIRED BV STATE, LOCAL AN� FEDERAL CO�ES WHETHER IN�ICATED OR NOT ON CONTRACT DOCUMENTS. THE SUBMISSIONS OF A BID WILL BE EVIDENCE THAT SUCH AN EXAMINATION AND COMPLIANCE WITH GOVERNING CODESIREQUIREMENTS HAS BEEN MADE LATER CLAIMS FOR LABOR, EQUIPMENT, OR MATERIALS REQUIRED, OR FOR DIFFICULTIES ENCOUNTERED WHICH COULD HAVE BEEN FORESEEN HA� AN EXAMINATION AND CO�E/REQUIREMENTS REVIEW BEEN MADE. WILL NOT BE ALLOWED. 1.G. D��ISS A�C�iITfCTS, „� a�• WALHALLA tOAD COLUMEUS, OHIO �saoi (bl�l ]064]]0 t R _¢' 2= 207 TATEOF ;��\ i �\ �'t'p NP'���5 4 F ' . I A ///////////%/%�lllll 11111\\\\ \\\����� • . "�• .pmu._o.e3..u��n� � U � U7 c+� w } � � � o � ��v � } � t � � � �Q�� Q�� _a L�� N � N � o N � •L �NU � a ^l C i � � U �n\ � W\ / Q PREPARED FOR Aveda Institute 16281 Tri Ridge Blvd Suife 140 Loveland, Ohio 45140 SHEET WFORMATION Prolec� N: 20013 luoed Por. BID / PERMIT Date: 5/29/20 Revisions'. �.yiiaaumi MECHANICAL DETAILS tiy:i�anomaaa M5.01