HomeMy WebLinkAboutP0.01-Plumbing Cover SheetPLUMBING NOTATIONS 140 140°FHOTWATER HP HORSEPOWER 140R 14�°F HOT WATER RETURN HT HEIGHT AD AREA DRAIN INV INVERT ELEVATION AFF ABOVE FINISH FLOOR LAV LAVATORV AFG ABOVE FINISHED GRADE LF LINEAR FOOT BFP BACKFLOW PREVENTER MAX MAXIMUM BV BALANGNGVALVE MG MECHANICALGONTRACTOR BT BATHTUB MIN MINIMUM CO CLFANOUT MS MOPSINK CS GLINICSINN NTS NOTTOSCALE CWS COMBINATION WATERSERVICE OD OVERFLOW DRAIN DCW �OMESTIC COLD WATER PC PLUMBING CONTRACTOR DD DEGK DRAIN RD ROOF DRAIN D�CV �OUBLEDETECTORCHECKVALVE S SINK DF �RINKINGFOUNTAIN SA SHOCKABSORBER DHW DOMESTICHOTWATER SAN SANITARY DHWR DOMESTIC HOT WATER RETURN SDL SPRINKLER DRAIN LWE �N �OWN SE SEWAGEEJECTOR DS DOWNSPOUT SF SQUAREFOOT DWH DOMESTIC WATER HEATER SH SHOWER EC ELECTRICALCONTRACTOR SP SUMPPUMP ET ERPANSION TANK SS SANITARY SEWER EWC ELECTRICWATERCOOLER STM STORM EWH E�ECTRICWATERHEATER SUC SITEUTILITVGOMRAGTOR FCO FLOORCLEANOUT SW SOFTWATER FD FLOORDRAIN T� TRENCH�RFIN FDG FIRE�EPARTMENTWNNECTION TMV THERMOSTATIGMIXINGVALVE FDV FlREDEPARTMENTVALVE TP TRAPPRIMER FOG FATS/OILS/GREASE TS TAMPERSWITCH FR FIRE RISER TVP TVPICAL FS FLOWSWITCH UF UTILITYFlXTURE FSC FIRESUPPRESSIONCONTRACToft uG UN�ERGROUND G GAS�NATURAL) UNO UNLESSNOTEDOTHERWISE GC GENERALWNTRACTOR UR URINAL GCO GRADECLEANOUT V VENT GPM GALLONS PER MINUTE VR VENT RISER GRD GRA�E VTR VENTTHROUGHROOF HB HOSEBIBB WG WATERCLOSET HC HVACCONTRACTOR WCO WALLCLEANOUT HCO HORIZONTALCLEANOUT WH WALLHVDRANT HD HUB�RAIN PLUMBING SYMBOL LEGEND NOTES: 1. ALL SVMBOLS MAY NOT APPLV. XX CODED PLAN NOiE XX DETAIL k y,XX SHEETp REFERENCETAG %X E�UIPMENTDESIGNATION BFP BACKFLOWPREVENTER {� BALANCIN6VALVE {pF BALLVALVE {� BUTTERFLYVALVE � CAP OFF EXISTING � CHECK VALVE � CLEANOIITPLUG �DCV DOIIBLEDETECTORCHECKVALVE ' DRY-PIPEVALVE � FlREALARMVALVE � FIRE�EPARTMENTCONNECTION e FIREPROTECTIONCONCEALEDSPRINKLER � FIRE PROTECTION PENDANT SPRINKLER � FIRE PROTECTION SPRINKLER WITH GUARD Q FlREPROTECTIONUPRIGHTSPRINKLER �-0 FLOORCLEANOUT � FLOOR DRAIN �S FLOW SWITCH �OF GASCOCK -0o- GATEVALVE � MIXINGVALVE � PIPINGDOWN — PIPINGOUTBOTTOM �Ir PIPINGOUTTOP } PIPINGRISEORDROP -0 PIPINGUP �7F PWGVALVE � POINTOFCONNECTION e PR6AGTIONVALVE � PRESSURERE�UGINGVALVE � RECIRCULATIONPUMP Do RWFIOVERFLOW�RAIN � SOLENOID VALVE �F STRAMER �S SUPERVISE�GATEVALVE �L TESTPLUG � THERMOMETER �I� UNION OM UTILITYMETER-GAS/WATER � WALLHYDRANTIHOSEBI6B PLUMBING LINETYPE LEGEND —:W- — �OMESTICCOL�WATER �GW DOMESTICCOL�WATER�EXISTING) �W DOMESTICHOTWATER �WR — — — DOMESTICHOTWATERRETl1RN � GAS ------5------- SANITARVUNOERGROUND ------(E)5------ SANITARYUNDERGROUND(EXISTMG) V VENT ALL OTHER LMETYPES DENOTED WITH: (AB) = ABAN�ONED; (D) _ �EMO; (E) = EXISTING GENERALNOTES�. A. THIS WORK SHALL BE EXECUTED IN STRICT CONFORMITY WITH THE LATEST E�ITION OF THE PREVAILING STATE PLUMBING AN� BUILDING CO�ES AND ALL LOCAL REGULATIONS THAT MAv APPLY. IN CASE OF CONFLICT BETWEEN THE CONTRACT DOCUMENTS AND A GOVERNING CODE OR ORDINANCE, THE MORE STRINGENT STANDARD SHALL APPLV. B. ALL PLUMBING FIXTURES SHALL BE SUPPLIED WITH INDIVIDUAL HEAVv DUTv SUPPLY STOPS AN� CODE APPROVE� P-TRAPS WITH CLEANOUTS EXPOSED PIPMG SHALL BE CHROME PLATED WITH CHROMED ESCUTCHEONS AT WALL PENETRATIONS. C. NOPIPMGSHALLPASS�IRECTLYOVERELECTRICALPOWERDISTRIBUTIONCABWETS. CONTRACTOR SHALL COORDINATE PANEL LOCATIONS, PRIOR TO PIPING INSTALLATION. �. ALL FLOOR DRAIN AND HUB �RAIN TRAPS SHALL BE PROVIDED WITH TRAP PRIMERS OR TRAPGUARDS,PERLOCALCODES. E. ALL HORIZONTAL VENT PIPING MAV NOT BE SHOWN ON THIS PLAN FOR THE SAKE OF CLARITY. REFER TO SANITARY ISOMETRIC PoR VENT PIPE ROUTMG AND PROVI�E COMPLETE VENTING SVSTEM IN ACCORDANCE WITH CODE. F. ALLPWMBMGWORKSHALLBECOORDINATE�WITHALLOTHERTRA�ES,PRIORTO CONSTRUCTION. G. ALL DOMESTIC WATER BRANCH LMES SHALL HAVE FULL PORT, TWO PIECE BALL TYPE, ISOLATION VALVES. H. PROVI�EWATERHAMMERARRESTORS(WHA)ASREQUIRED.WITH�IIICKCLOSMG VALVES AND ON SYSTEMS WITH HIGHER THAN NORMAL PRESSURE, WHERE WATER HAMMER MAY BE AN ISSUE. I. INSTALL ALL FLOOR CLEANOUTS TO CLEAR EQUIPMENT AN� PROVIDE REQUIRED ACCESSIBILITV FOR MAINTENANCE. J. VERIFVINVERTELEVAT10NSANDEXACTLOCAT10NSOFALLUNDERGROUNDUTILITIES, PRIOR TO INSTALLING ANV UNDERGROUND PIPMG. COORDINATE WITH SRE UTILIN CONTRACTOR. 1.G. D��ISS ARC�iITfCTS, «< a�� WALHALLA tOAD COLUMlUS, OHIO �s�oo la�l �os.n�o � R _ ] 207 4TEOF ;'� W; ��ANP.G?\ � �p NAL E_.�P�� ., .�,...� .....,.�,�,uo.E3..w���,��.� U Q� w } o �� d } � � � � �L �^l W L �..L � � � t' N N �.�j � � � � in V U L � � � C C � p a� a Q � C p � _ L w � N � N O �`+ o 6N U N � C � L U N � PREPARED FOR Aveda Institute 16281 Tri Ridge Blvd Suite 140 Loveland, Ohio 45140 SHEET WFORMATION Prolect p: 20013 luoed Por. BID / PERMIT Da�e: 5/29/20 Revlsions'. � PEServices ENGINEERIN6 FOR VOUR 5U[[E55 1-513-636-3810 vwvw.pe-servi�es.com �.y:ieamne RELEA5E0 FOR CONSTRUCTION Suhjec� �o compliance with all regula�ions 04 S�a�e antl Local Codes City of Carmel `�y,:a���'.�'� �,�:;vaYa/„1��. DATE: O��0��20 IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO NOTIFY THE ARCHITECT, LANDLOR� AND TENANT OF ANY DISCREPANCIES ENCOUMERED ON THE PLANS OR IN EXISTING SITE CONDITIONS PRIOR TO SUBMISSION OF BID. BIDDERS ARE TO VISIT THE SITE AND FAMILIARIZE THEMSELVES WITH EXISTING CONDITIONS AND SATISFY THEMSELVES AS TO THE NATURE AND SCOPE OF THE WORK. THE BASE BID SHALL REFLECT MODIFICATIONS TO SYSTEMS AND DEVICES AS REDUIRED BV STATE, LOCAL AN� FEDERAL CODES WHETHER INDICATED OR NOT ON CONTRACT DOCUMENTS. THE SUBMISSIONS OF A BID WILL BE EVIDENCE THAT SUCH AN EXAMINATION AN� COMPLIANCE WITH GOVERNING CODESIRE�UIREMENTS HAS BEEN MADE LATER CLAIMS FOR LABOR, EQUIPMENT, OR MATERIALS RE�UIRED, OR FOR DIFFICULTIES ENCOUNTERED WHICH COULD HAVE BEEN FORESEEN HAD AN E%AMINATION AND CO�E/REpl11REMENTS REVIEW BEEN MADE, WILL NOT BE ALLOWED. PLUMBING COVER SHEET FYiIqi�RqJil:7q 7 P0.01