HomeMy WebLinkAboutP0.01-Plumbing Cover SheetPLUMBING NOTATIONS
140 140°FHOTWATER HP HORSEPOWER
140R 14�°F HOT WATER RETURN HT HEIGHT
AD AREA DRAIN INV INVERT ELEVATION
AFF ABOVE FINISH FLOOR LAV LAVATORV
AFG ABOVE FINISHED GRADE LF LINEAR FOOT
BFP BACKFLOW PREVENTER MAX MAXIMUM
BV BALANGNGVALVE MG MECHANICALGONTRACTOR
BT BATHTUB MIN MINIMUM
CO CLFANOUT MS MOPSINK
CS GLINICSINN NTS NOTTOSCALE
CWS COMBINATION WATERSERVICE OD OVERFLOW DRAIN
DCW �OMESTIC COLD WATER PC PLUMBING CONTRACTOR
DD DEGK DRAIN RD ROOF DRAIN
D�CV �OUBLEDETECTORCHECKVALVE S SINK
DF �RINKINGFOUNTAIN SA SHOCKABSORBER
DHW DOMESTICHOTWATER SAN SANITARY
DHWR DOMESTIC HOT WATER RETURN SDL SPRINKLER DRAIN LWE
�N �OWN SE SEWAGEEJECTOR
DS DOWNSPOUT SF SQUAREFOOT
DWH DOMESTIC WATER HEATER SH SHOWER
EC ELECTRICALCONTRACTOR SP SUMPPUMP
ET ERPANSION TANK SS SANITARY SEWER
EWC ELECTRICWATERCOOLER STM STORM
EWH E�ECTRICWATERHEATER SUC SITEUTILITVGOMRAGTOR
FCO FLOORCLEANOUT SW SOFTWATER
FD FLOORDRAIN T� TRENCH�RFIN
FDG FIRE�EPARTMENTWNNECTION TMV THERMOSTATIGMIXINGVALVE
FDV FlREDEPARTMENTVALVE TP TRAPPRIMER
FOG FATS/OILS/GREASE TS TAMPERSWITCH
FR FIRE RISER TVP TVPICAL
FS FLOWSWITCH UF UTILITYFlXTURE
FSC FIRESUPPRESSIONCONTRACToft uG UN�ERGROUND
G GAS�NATURAL) UNO UNLESSNOTEDOTHERWISE
GC GENERALWNTRACTOR UR URINAL
GCO GRADECLEANOUT V VENT
GPM GALLONS PER MINUTE VR VENT RISER
GRD GRA�E VTR VENTTHROUGHROOF
HB HOSEBIBB WG WATERCLOSET
HC HVACCONTRACTOR WCO WALLCLEANOUT
HCO HORIZONTALCLEANOUT WH WALLHVDRANT
HD HUB�RAIN
PLUMBING SYMBOL LEGEND
NOTES:
1. ALL SVMBOLS MAY NOT APPLV.
XX CODED PLAN NOiE XX DETAIL k
y,XX SHEETp REFERENCETAG
%X E�UIPMENTDESIGNATION
BFP BACKFLOWPREVENTER {� BALANCIN6VALVE
{pF BALLVALVE {� BUTTERFLYVALVE
� CAP OFF EXISTING � CHECK VALVE
� CLEANOIITPLUG �DCV DOIIBLEDETECTORCHECKVALVE
' DRY-PIPEVALVE � FlREALARMVALVE
� FIRE�EPARTMENTCONNECTION e FIREPROTECTIONCONCEALEDSPRINKLER
� FIRE PROTECTION PENDANT SPRINKLER � FIRE PROTECTION SPRINKLER WITH GUARD
Q FlREPROTECTIONUPRIGHTSPRINKLER �-0 FLOORCLEANOUT
� FLOOR DRAIN �S FLOW SWITCH
�OF GASCOCK -0o- GATEVALVE
� MIXINGVALVE � PIPINGDOWN
— PIPINGOUTBOTTOM �Ir PIPINGOUTTOP
} PIPINGRISEORDROP -0 PIPINGUP
�7F PWGVALVE � POINTOFCONNECTION
e PR6AGTIONVALVE � PRESSURERE�UGINGVALVE
� RECIRCULATIONPUMP Do RWFIOVERFLOW�RAIN
� SOLENOID VALVE �F STRAMER
�S SUPERVISE�GATEVALVE �L TESTPLUG
� THERMOMETER �I� UNION
OM UTILITYMETER-GAS/WATER � WALLHYDRANTIHOSEBI6B
PLUMBING LINETYPE LEGEND
—:W- — �OMESTICCOL�WATER
�GW DOMESTICCOL�WATER�EXISTING)
�W DOMESTICHOTWATER
�WR — — — DOMESTICHOTWATERRETl1RN
� GAS
------5------- SANITARVUNOERGROUND
------(E)5------ SANITARYUNDERGROUND(EXISTMG)
V VENT
ALL OTHER LMETYPES DENOTED WITH:
(AB) = ABAN�ONED; (D) _ �EMO; (E) = EXISTING
GENERALNOTES�.
A. THIS WORK SHALL BE EXECUTED IN STRICT CONFORMITY WITH THE LATEST E�ITION OF
THE PREVAILING STATE PLUMBING AN� BUILDING CO�ES AND ALL LOCAL REGULATIONS
THAT MAv APPLY. IN CASE OF CONFLICT BETWEEN THE CONTRACT DOCUMENTS AND A
GOVERNING CODE OR ORDINANCE, THE MORE STRINGENT STANDARD SHALL APPLV.
B. ALL PLUMBING FIXTURES SHALL BE SUPPLIED WITH INDIVIDUAL HEAVv DUTv SUPPLY
STOPS AN� CODE APPROVE� P-TRAPS WITH CLEANOUTS EXPOSED PIPMG SHALL BE
CHROME PLATED WITH CHROMED ESCUTCHEONS AT WALL PENETRATIONS.
C. NOPIPMGSHALLPASS�IRECTLYOVERELECTRICALPOWERDISTRIBUTIONCABWETS.
CONTRACTOR SHALL COORDINATE PANEL LOCATIONS, PRIOR TO PIPING INSTALLATION.
�. ALL FLOOR DRAIN AND HUB �RAIN TRAPS SHALL BE PROVIDED WITH TRAP PRIMERS OR
TRAPGUARDS,PERLOCALCODES.
E. ALL HORIZONTAL VENT PIPING MAV NOT BE SHOWN ON THIS PLAN FOR THE SAKE OF
CLARITY. REFER TO SANITARY ISOMETRIC PoR VENT PIPE ROUTMG AND PROVI�E
COMPLETE VENTING SVSTEM IN ACCORDANCE WITH CODE.
F. ALLPWMBMGWORKSHALLBECOORDINATE�WITHALLOTHERTRA�ES,PRIORTO
CONSTRUCTION.
G. ALL DOMESTIC WATER BRANCH LMES SHALL HAVE FULL PORT, TWO PIECE BALL TYPE,
ISOLATION VALVES.
H. PROVI�EWATERHAMMERARRESTORS(WHA)ASREQUIRED.WITH�IIICKCLOSMG
VALVES AND ON SYSTEMS WITH HIGHER THAN NORMAL PRESSURE, WHERE WATER
HAMMER MAY BE AN ISSUE.
I. INSTALL ALL FLOOR CLEANOUTS TO CLEAR EQUIPMENT AN� PROVIDE REQUIRED
ACCESSIBILITV FOR MAINTENANCE.
J. VERIFVINVERTELEVAT10NSANDEXACTLOCAT10NSOFALLUNDERGROUNDUTILITIES,
PRIOR TO INSTALLING ANV UNDERGROUND PIPMG. COORDINATE WITH SRE UTILIN
CONTRACTOR.
1.G. D��ISS
ARC�iITfCTS, «<
a�� WALHALLA tOAD
COLUMlUS, OHIO �s�oo
la�l �os.n�o
� R
_
] 207
4TEOF ;'�
W;
��ANP.G?\
� �p
NAL E_.�P��
., .�,...� .....,.�,�,uo.E3..w���,��.�
U Q�
w }
o ��
d }
�
�
�
�
�L
�^l
W
L
�..L
�
�
�
t'
N N �.�j
� � �
� in V
U L �
� � C
C � p
a� a
Q � C
p � _
L w �
N �
N O
�`+ o
6N U
N
�
C
�
L
U
N
�
PREPARED FOR
Aveda Institute
16281 Tri Ridge Blvd
Suite 140
Loveland, Ohio 45140
SHEET WFORMATION
Prolect p: 20013
luoed Por. BID / PERMIT
Da�e: 5/29/20
Revlsions'.
�
PEServices
ENGINEERIN6 FOR VOUR 5U[[E55
1-513-636-3810
vwvw.pe-servi�es.com
�.y:ieamne
RELEA5E0 FOR CONSTRUCTION
Suhjec� �o compliance with all regula�ions
04 S�a�e antl Local Codes
City of Carmel
`�y,:a���'.�'� �,�:;vaYa/„1��.
DATE: O��0��20
IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO NOTIFY
THE ARCHITECT, LANDLOR� AND TENANT OF ANY
DISCREPANCIES ENCOUMERED ON THE PLANS OR IN
EXISTING SITE CONDITIONS PRIOR TO SUBMISSION OF BID.
BIDDERS ARE TO VISIT THE SITE AND FAMILIARIZE
THEMSELVES WITH EXISTING CONDITIONS AND SATISFY
THEMSELVES AS TO THE NATURE AND SCOPE OF THE WORK.
THE BASE BID SHALL REFLECT MODIFICATIONS TO SYSTEMS
AND DEVICES AS REDUIRED BV STATE, LOCAL AN� FEDERAL
CODES WHETHER INDICATED OR NOT ON CONTRACT
DOCUMENTS. THE SUBMISSIONS OF A BID WILL BE EVIDENCE
THAT SUCH AN EXAMINATION AN� COMPLIANCE WITH
GOVERNING CODESIRE�UIREMENTS HAS BEEN MADE LATER
CLAIMS FOR LABOR, EQUIPMENT, OR MATERIALS RE�UIRED,
OR FOR DIFFICULTIES ENCOUNTERED WHICH COULD HAVE
BEEN FORESEEN HAD AN E%AMINATION AND
CO�E/REpl11REMENTS REVIEW BEEN MADE, WILL NOT BE
ALLOWED.
PLUMBING COVER
SHEET
FYiIqi�RqJil:7q 7
P0.01