Loading...
HomeMy WebLinkAboutFlrEnlarged_A108WALL TYPES: GENERAL NOTES: 1. WHERE TILE IS SHOWN ON WALLS ON INTERIOR ELEVATIONS AND RNISH PLANS, REPLACE GVPSUM BOARD IN TILE AREA WITH TLLE BACKERBOARD. MAINTAINFIRERATINGWHEREREQUIRED. 2 REFERENCE LIFE SAFETV PLANS FOR WALL RATINGS/SEPAR4TION5 - NOTIFV ARCHITECT OF ANV DISCREPANCIES BETWEEN LIFE SAFETV PLAN AND WALLTVPE TAGS ON PLANS FOR CLARIRCATION PRIOR TO CONSTRUCTION. W1 EXISTING wALL WITH GVPSUM BOARD FlNISH. PATCH AND REPAIR EXISTWG GVPSUM BOARO AS NEEDED. RERNISH EXISTING RERNISH EXISTING GVPSl1M BOARD GVPSUM BOAR� AN� RNISH WITH 3 COATS OF PAINT PER RNISH SCHEOULE. EXISTING WALL ON EXISTING EXTERIOR WALLS - RERNISHEXISTING PATCH/REPAIRIFINISH/PAINTON GVPSUM eOAR❑ INTERIOR SIDE ONLV. ON EXISTING INTERIOR WALLS - PATCH/REPAIR/FlNISH/PAINT ON BOTH SIDES OF WALL. IN AREAS WHERE CEILING INTERSECTS WALL, TERMINATE FINISH 6" ABOVE FINISH CEILING. NOTE: IN AREAS WHERE EXISTING WALL FINISHES HAD PREVIOUSLV TERMINATE� AT EXISTING CEILING HEIGHTS AND ARE NOW IN E%POSED CEIL W G AREAS, EXTEND DRYWALL FINISH UP TO EXPOSED METAL OECK/STRUCTURE ABOVE - FINISH AND PAINT WZ NEW EXTERIOR WALLAS PART OF INTERIORRNISHSPACE LANDLORDISHELLWORK. INTERIOR FACE OF WALL TO HAVE GVPSUM REFlNISHEXISTING BOARDANDTAPHFlNISH.TENANT _� GVPSUM BOAR� � WORK WCLUDES PAINTING EXISTING GVPSUM BOARD FROM BASE TO 6" ABOVE FINISH CEILING. E%ISTING WALL 3 5/8" METAL STUDS AT i6" O.C. W3 INSTALL 1 LAVER OF 5/8" GVPSUM BOARD ON BOTH SIDES OF WALL- FINISH AND PAINT PER FINISH SCHE�ULE IN AREAS OF EXPOSED CEILINGS EXTEND FRAMMG AND � GVP. BD. TO DECK. IN AREAS OF SUSPENDED CEILING, STUDS AND GVP.BD.CAN TERMINATE6"ABOVE " FINISHCEILING-BRACESTUDSTO "' �ECKAT4'-0"O.C.MIN. WHERE FRAMING EXTENDS TO DECK, USE �EFLECTION TRACK AT STRUCTURE CONNECTION. NOTE: IN SOME AREAS, W3 WALL TAG IS SHOWN TO INFILL EXISTING OOOR OPENINGS. W THESE CASES, INSTALL NEW METAL STUDS AND FlNISH DRYWALL RUSH WITH EXISTING/ADJACENT WALL SURFACE. 3 5/8" METAL STUOS AT 76" O.C. W4 INSTALL 1 LAVER OF SIB" GVPSUM BOARD ON ONE (ROOM FINISH) SIDE OF WALL - FINISH AND PAINT PER FINISH SCHEDULE. IN AREAS OF EXPOSEDCBLWGS,EXTEND � FRAMING AND GYP. BD. TO DECK. IN AREAS OF SUSPENDED CEILING, STUDS AND GVP. B0. CAN TERMINATE 6" ABOVE FINISH CEILWG - BRACE STUDS TO DECK AT 4'-0" O.C. MIN. WHERE FRAMING EXTENDS TO DECK, USE �EFLECTION TRACK AT STRUCTURE CONNECTION. 1-HOUR RATED ASSEMBLY � NOTE:WFlLLWORKOFE%ISTWG OPENINGS INCLU�ING STU�S AND " GVPSUM BOAR� IS TO BE PROVIDED ASPARTOFLANDLOR�PACKAGE, NOTTENANTFINISH. THERATED - WALLASSEMBLYISSHOWNFORPLAN � REVIEW PURPOSES ONLV. THE TENANT RNISH CONTRACTOR SHALL PLAN TO PROVIDE FINISH WORK/PAINT ON TENANT FINISH SIOE "' ONLV IN THIS AREA. 3 5/8" METAL STUDS AT i6" O.G ON EACH SIDE OF OPENING. INSTALL 1 LAVER OF SB" "TVPE X" GVPSUM BOARD ON BOTH SIDES OF WALL EXTEND FRAMWG AND GYP. BD. TO FULL HEIGHT OF OPENING AND FINISH F W SH W ITH ADJACENT GVPSUM BOARD WALL FINISHES. FIRE CAULK JOINTSTOPANDBOTTOM. FINISH AND PAINT PER SCHE�ULE. W6 TENANT FINISW PROJECTSCOPEAREA EXISTING INTERIOR DEMISING WALL ADJACENTTENANT (NOT IN SCOPE) 1-HOUR R4TED ASSEMBLY I EXISTING INTERIOR DEMISING WALL WITH GVPSUM BOARD FINISH. CONTRACTOR TO PROVIDE SELECT DEMOAN� VERIFV EXISTING WALL ASSEMBLV. DEMISINGWALLIS REQUIRED TO PROVIDE A 1-HOUR RATED SEPARATION FROM ADJACENT TENANT SPACE. ONCE EXISTING WALL ASSEMBLV IS VERIFIED IN THE RELq COORDINATE WITH ARCHITECT ON PATCH, REPAIR, OR ADDITIONAL LAVERS TO BE ADDED IF REQUIRED TO MEET 1 HOl1R RATING. 2 LAVERS OF TVPE %GVPSUM BOARD IS REQUIRED TO MEET 7 HOUR RATING - THIS CAN BE ONE LAVER ON EACH SIDE OR 2 LAVERS ON ONE SIDE. COOROINATEWITHARCHITECT CONTRACTOR TO VERIFV ALL PENETRATIONSIPERIMETER HAS BEEN SEALED WITH RRE CAULK. NOTE: IN AREAS WHERE EXISTING WALL FINISHES HAD PREVIOUSLV TERMINATED AT EXISTWG CEILING HEIGHTS AND ARE NOW IN EXPOSED CEILING AREAS. EXTEND DRVWALL FINISH UP TO EXPOSED METAL OECKISTRUCTIIRE ABOVE - FINISH AND PAINT. 1-HOUR RATED ASSEMBLY � NOTE:INFlLLWORKOFE%ISTWG OPENWGS WCLUDMG STUDS AND ; GYPSUM BOAR� IS TO BE PROVIDED ASPARTOFLANDLORDPACKAGE, NOTTENANTFINISH. THERQTED WALL ASSEMBLV IS SHOWN FOR PLAN � RENEW PURPOSES ONLV. THE TENANT RNISH CONTRACTOR SHALL PLAN TO PROVIDE FINISH WORK/PAINT ON TENANT FINISH SIDE ONLV IN THIS AREA. 3 5/8" METAL STUDS AT i6" O.C. INSTALL 1 LAVER OF SIS" "TVPE X" GVPSUM BOARD ON BOTH SIDES OF WALL EXTEND FRAMING AND GVP. BD. TO FULL HEIGHT OF OPENWG AND FlNISH FLUSH WITH ADJACENT GVPSUM BOARD WALL FINISHES. FIRE CAULK JOINTS TOP AND BOTTOM. FINISH AND PAINT PER SCHEDULE. w � � � U W � 2 UA' 1..� � W H �/ / PLAN REVIEW / PERMIT SET °c�rvoP€; n°e�oRne� re�mma�OeM a a o0 �oa*ews�eo�. s.iszozo� rrevisiomsissueu SITE ARCHITECTURE PROJECT CONTACT'. BRA�SMITH RA LEE�AP 13144 EAST 186TH STREET NOBLESVILLE M. 06060 PH' 3P3]6 8]20 EJAAIL batl@sIR¢rcM1lRdure.mm ENGINEER: Sl11TE 100 � 1� tI i 2w _/ W li L,L � � W J � W Z NL r Z W G W > ON I.L a G ,2^ V/ Z � H Q W � r W � � N 2L r.^ W N r r � Q Y,A/ Y/ � � M M '0^ W � Z J C Q U WALLTVPES RELEA5E0 FOR CONSTRIICTI�N Su6jec� �o compliance with all regula�ions of S�a�e antl Local Codes City of Carmel r �un��\i lo•rvalM��_ DATE: 07�� 3�20 A108 2020-007