HomeMy WebLinkAboutPlumb_P106w
<
MATCH LINE l �
EXTERIOR I \
w
¢
SEAFOOD
COOLER
� 141
SEAFOOD
PREP
160
EXTERIOR
WOMEN RR
138 �
MEN RR
DELI
COOLER
EXTERIOR
RELEASEO FOR CONSTRl1CTI0N
Su6ject to compliance with all regulations
of State and Local Codes
City of Carniel
�
y ��m� V"? \oxv�A'v».T �.
DATE: 07�'�'3�2�
u Appmximate location
of existinq 4" Sanitary
_..YJas�eEipio9._.
MEAT
COOLER
L � II
Exist I
Q_I3
O
eii=tia=ii� v �i I �i �i �i
iii ii ii' HD-1 i p i i i
a Approxima�e location � � � �.� i i� � � � O �
..._.._. _..¢��.�t�'q..��._.. . _.._.. .._.._. _. .._. _.. .._.._. _.._.._. _.._..�.._.._.._�i. ��._.._.._.�i_.._.. MEAT
��
� Was�e PiPin9. �i i MEAT i - —� —ii 1 V
'i i COUNTER �� ��i O
iq2 �u u
z W� 9 D '�� o
i �
ri � —I � i
o ¢ —�i �----�
8 ���
5 � c�
ioN 6 �ExisL �
�� floortlreln :
— — —� CORR � '
� HD-0
� � 139
al al � �EWC�1 O� �
� �� i �
— //
// ` //
CORR
136 2^W ] 9
O O N 2OEWC�IA
]3I �I � �I HD�1
_ _
� I n � P� 0
Appmxima�e low�ion
ofexis�ing 4"Grease
Waste Piping �
DELI
STOR
134 Exis�.
lloortlrain
—
� DELI �2 W��
O9 z"CWbelowslab. 118 \
minimum 18" cover.
I
DELI PREP O?^Cw below slab,
133 minimum 18" com
____'��i•_ _ �i%___ �___' I
Exist w
floor tlrain �
`� '" i �i i �I i�
� �r i�_1 F__ F _� i
rt rt--P +--
� __ i•
3 %SE � �� 1tR f� i�
� I If_1
�,I y_,�14 °�i i ii_
n � __�
up �o
HD-1
3"W O9
� EESE �� �
ISL /
11 �
HD�1 `✓ � I
2 W� �O
3"W ] 9
/ //
BAKERY
119
Exism
Iloor drein
�
�
3"GreaseO
//
�
�
Appmximaie loca�ion
o� exlstlng 3" Senl[ary
Was�e Pipi�g.
// // � //
i.._..�
__i____________________ � .
T iii
�i 1 �iii
m
� O 1 w
w
v I O9 GreaseJ ' SI-1
SH �132 �
Exist lloor
�hydrant
3"GreaseO9
ORFASE GRFASE
/� �i i� — _ i l
�+___i�r____rJ
i
�
� � � g 2"Grea:
u___' �____�
EXISt.
floor tlrain � 4
`Appmximatelocation �� �z �p �p >> �g `Approximatelowtion o o I I
ofexisting 4" Grease ofexisting 4"Grease i � I I
Waste Piping. Waste Piping �
EXTERIOR EXTERIOR
STAIR A
���, � FIRST FLOOR PLUMBING - AREA 4 ENLARGED PLAN
T SCALE: 3/16" = 1'-0"
xl
CO-1
�Exisi
iloor
AREA
BAN
PF
C
3
� KEY PLAN
General Notes:
A. All fittings, piping, fixtures, materials, etc. to meetthe
curtent Sa�e D�inking Water Actwith allofits
amentlmen�s antl the Retluc[ion o� Leatl in Drinking
water Act.
B. Allwork shallcomply with allna[ional,slate,localcotles
antl ortlinances pertaining �o �he work in �his pmlec�.
C. AIl plumbingll�urea shall be aupplletl wl�h Intllvltlual
water supply s[ops antl cotle approvetl Vaps Exposetl
piping shallbe chmme pla[ed.
D. All plumbing lixWres shall be inslalletl wi�h approvetl
backllow preven�ion tlevices.
E. No piping shall pass dlrectly over eledrical power
disvibution cabinets, panelboards, etc. Conirector to
coortlinate panelloca�ions prior�o piping ins�alla�ion.
E All plumbing ven�s �o be a minimum of 10'-0" irom any air
Intake. Coordina�e loca�ions wilh HVAC plans.
G. Single runoNs to plumbing fixWres shall be �he same
size as on Ne plumbing IixWre schetlule unless
o�herwise no�etl.
H. Concealed gas pipinq shall be cons�mctetl in accordance
with cotle without unions, Wbing linings or mnning
ihreatls.
I. Gas lines run on wof �o be supported by Rool Top Blox
or similar and equal. DO NOT USE LUMBER FOR GAS
PIPING SUPPORT.
J. �ry-pipe fire pm�ec�ion system shall be used in all areas
subled to heezing.
K. NII was�e, wa�er, ven�. gas antl cantlensate lines shown
to be connec�ed �o �heir associated firture/equipment
unless no�etl o[herwise. All equipmen[ antl sys[ems
shown mus� be comple�e antl usable upon comple�ion oi
pralec�.
Plan Notes:
OExtend case drain to nearest hub drain.
O2 Connect new fixture to nearest existing water, waste and
vent pipes seming removed fixture. AdlusVex�end
exis�ing utili�ies asrequired�o suit new fixture
rype/looa�ioa Repair floor/wall in ktnd, ready for finlsR
O3 a"CW & a"HW down along wall �o serve �wo (2) sinks.
Holtl pipes astiqhito wall as praclical.
O4 '�"CW 8}"HW down along walL Hold pipes as �ight �o
wall as practical. Ex[end �'CW &�'HWto serve sink.
Extend a"CWto below slab
ONtljusl exis�ing waste sWb imm below slab to serve new
floorsink Fepairslabinkind,readyforfinish.
OConned newlixWre m exis�inq wa�erpipes,servinq
removed ilxNre. Adjust/extend existing utilities as
requiretl to suit new flxture type�location.
OConnect new was�e piping to neares� active was�e pipe
ofequalorlergarsize. Field vanfy exactsize,locatioq
eleva�ion, matarialand condition ofexis�ing waste pipe;
prior�o start oiwork.
OConnect new water pipa(s) �o neeres� ecfrve water
plpe(aJ o! equal oNerger slze. Fieltl verity exacl slze,
low[ion, eleva[ion, materialantl contlition ofexisting
wa�erpipe(s);prior�o s�ah olwork.
ONea�ly saw-cu� existing slab alonq entire path of new
utllity, vetlfy peth prior to s[atl of work. Repair alab In
kintl, reatly for (inish.
10 Provide 1'G line connectetl to existing hoo8s fire
suppression system to serve Kitchen Equipment Field
varify exao� siz& bcatioq ma�arial and condl�ion oi
exis�ing gas pipe;prior�o statl oiwork.
11 Provide 1';'G line connec�ed to exis�inq hoo8s fire
suppression sys�em �o serve Kitchen Equipment Field
varify exao� size, locatioq ma�afial antl contli�lon oi
exis�ing gas pipe;prior�o s[atl oiwork.
12 Provide a"G line �o serve Ki�chen Equipment Provitle
48" exVa, flexible gas line in a loop behintl equipmen�.
Te�her loop to ifs respec�ive piece of equipmenL See
Ki�chen Equipmen�Suppller's plansiormorelniorma�ion.
13 This was�e piping mus� be Cas� Imn.
14 Repipe existing floor tlrain ro tlischarge in�o Sanitary
Grease Was�e pipe.
15 Pmvide 1 j"G line �o serve Ki�chen Equipment Pmvide
a8" extra, flexible gas line in a loop behintl equipment.
Tefier loop to ifs respective piece of equipmenl See
Kitchen EquipmeN Supplier's plans for more iniorma�ion.
w^'�
L
Ii �
U
� �
.�
��
U
U`
�
w�
�
H�
U
2 �
�
�
U�
�+
\ W
�
�
W a�
� �i
�
— U
' /� L
V% �
PLANREVIEW PEFMITSET
.n�aaa.
�aa�a.c Po aae�:4'
vsorvsssuEo ���.mzo
ARCHITECT:
SITE ARCHITECTURE
amni�eaure � ienmcepe emnitecmre
PROJECTCONTHCT�.
BRA� SMITH, RA I LEE� AP
13144 EASTi06TH STREET
NOBLESVILLE IN.06060
PH' 311.3]6 BRO
EJr1AIL�.b�atlQsite-ercM1iteclure wm
MEP ENGINEER:
THE ENGINEERING
COLLABORATNE
PROJ W T CONTACT:
SAMHURT P.E.
24ID EXECIITIVE DRIVE,SUITEIO�
INDIANAPOLIS IN.46241
PR 91l 648 994�
6MAIC. sum@Ico-map.aom
W
1� �
Q W
` �
W
2>�
W�W
�a�
� � N M
� N � �
� Z � �
LLI LL � Z
J F. cn �
W a W �
W Z � �
ZH� V
rircsi hLOUR
PLUMBING -AREA 4
ENLARGEDPLAN
P106
2020-007I