Loading...
HomeMy WebLinkAboutA1.2 - PLANS - PAVILIONA4.1 2 A4.1 1 A4.13 A4.14 FAMILY RESTROOM 104 1'-6"EXISTING EXPOSED STRUCTURE TO BE PAINTED. PT-1. TYP. LINE OF SOFFIT ABOVE PROVIDE ADDITIONAL CONVENIENCE OUTLETS. REFER TO ELECTRICAL. PROVIDE ADDITIONAL CONVENIENCE OUTLETS. REFER TO ELECTRICAL. INFILTRATION TRENCH. REFER TO CIVIL INFILTRATION TRENCH. REFER TO CIVIL PVC CONDUIT FOR CAMERA. REFER TO CIVIL. CAMERA BY OWNER. PVC CONDUIT FOR CAMERA. REFER TO CIVIL. CAMERA BY OWNER. 8 A5.1 SIM. CONTINUOUS RIDGE CAP. STANDING SEAM METAL ROOF. 1/2" RIB HEIGHT SPACED AT 18". 10 A5.1 SNOW GUARD. SNOW GUARD. A. THE CONTRACTOR IS RESPONSIBLE FOR THE COORDINATION FOR ALL PARTS OF THE WORK SO THAT NO WORK SHALL BE LEFT IN AN UNFINISHED OR INCOMPLETE CONDITION. B. ALL WORK SHALL CONFORM TO THE APPLICABLE INDUSTRY AND MANUFACTURER'S PUBLISHED STANDARDS. C. NO SUBSTITUTIONS FOR ITEMS SPECIFIED WILL BE ACCEPTED WITHOUT PRIOR WRITTEN ACCEPTANCE FROM THE ARCHITECT / DESIGNER AND OWNER. D. THE CONTRACTOR SHALL PROTECT EXISTING WORK AND OTHER NEW WORK BY OTHER CONTRACTORS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DAMAGE TO EXISTING WORK OR WORK BY OTHERS INCURRED WHILE FULFILLING THE OBLIGATIONS OF THE CONTRACT. E. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND SHALL VERIFY ALL NEW AND EXISTING CONDITIONS SHOWN ON THESE DRAWINGS. THE CONTRACTOR SHALL NOTIFY THE ARCHITECT / DESIGNER OF ANY DISCREPANCIES, OMISSIONS AND/OR CONFICTS BEFORE COMMENCEMENT OF WORK. COMMENCEMENT OF WORK SHALL CONSTITUTE ACCEPTANCE OF ALL NEW OR EXISTING CONDITIONS. F. WHERE DESIGN INTENT CANNOT BE DETERMINED FROM THE CONSTRUCTION DOCUMENTS, THE CONTRACTOR IS RESPONSIBLE FOR OBTAINING A CLARIFICATION FROM THE ARCHITECT / DESIGNER PRIOR TO PROCEEDING WITH THE WORK IN QUESTION. G. SUBMITTALS OF ALL FINISH MATERIALS REQUIRED TO ARCHITECT / DESIGNER FOR APPROVAL PRIOR TO ORDERING OR INSTALLING TO INSURE ACCURACY OF SPECIFIED PRODUCT WITH INSTALLED MATERIAL. H. LEAD TIMES FOR ALL SPECIFIED MATERIALS VARY. PURCHASING CONTRACTOR AND/OR SUPPLIER ASSUMES RESPONSIBILITY FOR VERIFYING LEAD TIME WITH MANUFACTURER AND ORDERING MATERIAL IN ACCORDANCE WITH PROJECT SCHEDULE AND COMPLETION DATE. I. VERIFY ALL MOUNTING LOCATIONS FOR TOILET ACCESSORIES AND ALL OTHER ACCESSORIES / APPURTENANCES WITH THE OWNER PRIOR TO INSTALLATION. END OF GENERAL NOTES. GENERAL NOTES EXISTING EXPOSED STRUCTURE TO BE PAINTED. PT-1. TYP. METAL PANEL CEILING ATTACHED TO EXISTING BEAD BOARD SOFFIT. APPROXIMATELY 200 SF OF DAMAGED BEAD BOARD SHALL BE REPLACED. REFER TO SECTION DETAILS EXISTING LIGHT TO REMAIN. EXISTING LIGHT TO REMAIN. 10 A5.1 FIBER CEMENT PANEL 1: SMOOTH. COLOR TO MATCH SW 6258 TRICORN BLACK. FIBER CEMENT PANEL 2: SMOOTH. COLOR TO MATCH SW 7674 PEPPERCORN. PT-1: SHERWIN WILLIAMS, COLOR: SW 6258 TRICORN BLACK. HIGH PERFORMANCE EPOXY COATING. PT-2: PITTSBURGH PARMOUNT COLOR: LIGHT GREEN. LATEX SEMI-GLOSS. ST-1: NAWKAW NAWTONE COLOR: MATCH EXISTING DARK MASONRY BANDS. LATEX FLAT. QZ-1: QUARTZ FLOORING. TORGINOL SIGNATURE BLENDS. COLOR: QB-1005 - OXFORD. MATERIALS AND FINISHES LEGEND 44 EAST MIFFLIN STREET SUITE 500 MADISON, WI 53703 608.251.1177 www.smithgroup.com 11640 500 PARK BOULEVARD SUITE 800 ITASCA, IL 60143 630.221.1212 www.williams-architects.com WEST PARK: THE CORE SEALS AND SIGNATURES KEY PLAN DRAWING TITLE PROJECT NUMBER SCALE DRAWING NUMBER 3030 W. 116TH STREET CARMEL, IN 46032 Owner: 12/31/2021 10/31/2021 ALL ARCHITECTURAL SHEETS A1.2 PLANS -PAVILION SCALE: 3/16" = 1'-0"1GROUND FLOOR SCALE: 3/16" = 1'-0"2ROOF PLAN SCALE: 3/16" = 1'-0"3REFLECTED CEILING PLAN NORTH NORTH NORTH 0'1.5'3'6'0'1.5'3'6' 0'1.5'3'6' 65% REVIEW 04/20/2020 90% CONSTRUCTION DOCUMENTS 06/01/2020 100% REVIEW 06/19/2020 ISSUED FOR BID 07/14/2020 . ISSUED FOR REV DATE 07/14/2020