HomeMy WebLinkAboutA1.0 GENERAL NOTESSOAP DISPENSER MIRROR ACCESSIBLE WATER CLOSETS ACCESSIBLE LAVATORIES GENERAL TOILET AND BATHING ROOMS SHALL COMPLY WITH SECTION 603. LOCATION. THE WATER CLOSET SHALL BE LOCATED WITH A WALL OR PARTITION TO THE REAR AND TO ONE SIDE. THE CENTERLINE OF THE WATER CLOSET SHALL BE 16 INCHES MINIMUM TO 18 INCHES MAXIMUM FROM THE SIDE WALL OR PARTITION. HEIGHT. THE HEIGHT OF THE WATER CLOSET SEATS SHALL BE 17 INCHES MINIMUM AND 19 INCHES MAXIMUM ABOVE THE FLOOR, MEASURED TO THE TOP OF THE SEAT. SEATS SHALL NOT BE SPRUNG TO RETURN TO A LIFTED POSITION. GRAB BARS. GRAB BARS FOR WATER CLOSETS SHALL BE PROVIDED ON THE REAR WALL AND ON THE SIDE WALL CLOSEST TO THE WATER CLOSET. GENERAL: LAVATORIES AND SINKS SHALL COMPLY WITH SECTION 606. CLEAR FLOOR SPACE. A CLEAR FLOOR SPACE COMPLYING WITH SECTION 305.3, POSITIONED FOR FORWARD APPROACH, SHALL BE PROVIDED. KNEE AND TOE CLEARANCES COMPLYING WITH SECTION 306 SHALL BE PROVIDED. THE DIP OF THE OVERFLOW SHALL NOT BE CONSIDERED IN DETERMINING KNEE AND TOE CLEARANCES. HEIGHT. THE FRONT OF LAVATORIES AND SINKS SHALL BE 34 INCHES MAXIMUM ABOVE THE FLOOR, MEASURED TO THE HIGHER OF THE RIM OR COUNTER SURFACE. FAUCETS. FAUCETS SHALL COMPLY WITH SECTION 309. HAND-OPERATED METERING FAUCETS SHALL REMAIN OPEN FOR 10 SECONDS MINIMUM. EXPOSED PIPES AND SURFACES. WATER SUPPLY AND DRAINPIPES UNDER LAVATORIES AND SINKS SHALL BE INSULATED OR OTHERWISE CONFIGURED TO PROTECT AGAINST CONTACT. THERE SHALL BE NO SHARP OR ABRASIVE SURFACES UNDER LAVATORIES AND SINKS. 6" MAX TOE CLEARANCE 8" MIN KNEE CLEARANCE 17" MIN DEPTH9"27" MIN29" MIN34" MAX44" MAX1'-6"40" 36" 40"34" 5" 18" 12" MAX 42" MIN 17"-19"15" STANDARDADA1'-6"34"24" 12" 36" 54" MIN 42" MIN 6" MAX SIDE FRONT SIDE FRONT FIXED SIDE WALL GRAB BARS. FIXED SIDE WALL GRAB BARS SHALL BE 42 INCHES MINIMUM IN LENGTH, LOCATED 12 INCHES MAXIMUM FROM THE REAR WALL AND EXTENDING 54 INCHES MINIMUM FROM THE REAR WALL. IN ADDITION, A VERTICAL GRAB BAR 18 INCHES MINIMUM IN LENGTH SHALL BE MOUNTED WITH THE BOTTOM OF THE BAR LOCATED BETWEEN 39 INCHES AND 41 INCHES ABOVE THE FLOOR, AND WITH THE CENTER LINE OF THE BAR LOCATED BETWEEN 39 INCHES AND 41 INCHES FROM THE REAR WALL. REAR WALL GRAB BARS. THE REAR WALL GRAB BAR SHALL BE 36 INCHES MINIMUM IN LENGTH, AND EXTEND FROM THE CENTERLINE OF THE WATER CLOSET 12 INCHES MINIMUM ON THE SIDE CLOSET TO THE WALL, AND 24 INCHES MINIMUM ON THE TRANSFER SIDE. WHERE ADMINISTRATIVE AUTHORITY REQUIRES FLUSH CONTROLS FOR FLUSH VALVES TO BE LOCATED IN A POSITION THAT CONFLICTS WITH THE LOCATION OF THE REAR GRAB BAR, THAT GRAB BAR SHALL BE PERMITTED TO BE SPLIT OR SHIFTED TO THE OPEN SIDE OF THE TOILET AREA. SHALL COMPLY WITH SECTIONS 609 AND 604. FLUSH CONTROLS. FLUSH CONTROLS SHALL BE HAND OPERATED OR AUTOMATIC. HAND OPERATED FLUSH CONTROLS SHALL COMPLY WITH SECTION 309 AND BE LOCATED ON THE OPEN SIDE OF THE WATER CLOSET. DISPENSERS. TOILET PAPER DISPENSERS SHALL BE 7 INCHES MINIMUM AND 9 INCHES MAXIMUM IN FRONT OF THE WATER CLOSET. THE OUTLET OF THE DISPENSER SHALL BE 15 INCHES MINIMUM AND 48 INCHES MAXIMUM ABOVE THE FLOOR. THERE SHALL BE A CLEARANCE OF 1-1/2 INCHES MINIMUM BELOW AND 12 INCHES MAXIMUM ABOVE THE GRAB BAR. DISPENSERS SHALL NOT BE OF A TYPE THAT CONTROL DELIVERY, OR THAT DO NOT ALLOW CONTINUOUS PAPER FLOW. COMPARTMENTS. THE MINIMUM AREA OF A WHEELCHAIR ACCESSIBLE COMPARTMENT SHALL BE 60 INCHES MINIMUM IN WIDTH MEASURED PERPENDICULAR TO THE SIDE WALL, AND 56 INCHES MINIMUM IN DEPTH FOR WALL HUNG WATER CLOSETS, AND 59 INCHES MINIMUM IN DEPTH FOR FLOOR MOUNTED WATER CLOSETS MEASURED PERPENDICULAR TO THE REAR WALL. ARCHITECT TO CONFIRM. DOORS- ARCHITECT TO CONFIRM WHEELCHAIR ACCESSIBLE TOILET COMPARTMENT DOORS, INCLUDING DOOR HARDWARE, SHALL COMPLY WITH SECTION 404. THE DOOR SHALL BE SELF-CLOSING. A DOOR PULL COMPLYING WITH SECTION 404.2.6 SHALL BE PLACED ON BOTH SIDES OF THE DOOR NEAR THE LATCH. WHEELCHAIR ACCESSIBLE TOILET COMPARTMENT DOORS SHALL NOT SWING INTO THE REQUIRED MINIMUM AREA OF THE COMPARTMENT. DOOR OPENING LOCATION THE FARTHEST EDGE OF THE WHEELCHAIR ACCESSIBLE TOILET COMPARTMENT DOOR OPENING SHALL BE LOCATED IN THE FRONT WALL OR PARTITION OR IN THE SIDE WALL OR PARTITION AS REQUIRED BY TABLE 604.9.3.1. TOE CLEARANCE. THE FRONT PARTITION AND AT LEAST ONE SIDE PARTITION SHALL PROVIDE A TOE CLEARANCE OF12 INCHES MINIMUM ABOVE THE FLOOR AND EXTENDING 8 INCHES BEYOND THE COMPARTMENT SIDE FACE OF THE PARTITION, EXCLUSIVE OF PARTITION SUPPORT MEMBERS. CLEARANCE: CLEARANCE AROUND A WATER CLOSET SHALL BE 60 INCHES MINIMUM IN WIDTH, MEASURED PERPENDICULAR FROM THE SIDE WALL. CLEARANCE AROUND THE WATER CLOSET SHALL BE 56 IN INCHES MINIMUM IN DEPTH, MEASURED PERPENDICULAR FROM THE REAR WALL. THE REQUIRED CLEARANCE AROUND THE WATER CLOSET SHALL BE PERMITTED TO OVERLAP THE WATER CLOSET, ASSOCIATED GRAB BARS, PAPER DISPENSERS, SANITARY NAPKIN RECEPTACLES, COAT HOOKS, SHELVES, ACCESSIBLE ROUTES, CLEAR FLOOR SPACE AT OTHER FIXTURES AND THE TURNING SPACE. NO OTHER FIXTURES OR OBSTRUCTIONS SHALL BE WITHIN THE REQUIRED WATER CLOSET CLEARANCE. 44 EAST MIFFLIN STREET SUITE 500 MADISON, WI 53703 608.251.1177 www.smithgroup.com 11640 500 PARK BOULEVARD SUITE 800 ITASCA, IL 60143 630.221.1212 www.williams-architects.com WEST PARK: THE CORE SEALS AND SIGNATURES KEY PLAN DRAWING TITLE PROJECT NUMBER SCALE DRAWING NUMBER 3030 W. 116TH STREET CARMEL, IN 46032 Owner: 12/31/2021 10/31/2021 ALL ARCHITECTURAL SHEETS A1.0 GENERAL NOTES AND SPECIFCATIONS GENERAL NOTES: 1. ALL WORK SHALL CONFORM TO STATE AND LOCAL CODES AND ORDINANCES AND SHALL COMPLY WITH THE 2014 INDIANA BUILDING CODE ANSI A117.1-2009. ALL WORK SHALL MEET OR EXCEED INDUSTRY STANDARDS FOR MATERIALS, AND WORKMANSHIP. 2. CONTRACTOR SHALL REVIEW THE DRAWINGS THOROUGHLY BEFORE PROCEEDING WITH ANY WORK; ANY DISCREPANCIES FOUND WITHIN THESE DOCUMENTS SHALL BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE OWNER. CONTRACTOR SHALL NOT PROCEED WITH ANY WORK HE KNOWS TO BE IN CONFLICT WITH OTHER WORK OR IS NOT APPROVED BY CODE, UNTIL RESOLVED BY THE OWNER. 3. FOOTINGS SHALL BE CONSTRUCTED ON UNDISTRIBUTED NATIVE SOIL OR ENGINEER APPROVED FILL. BACKFILL AROUND BUILDING TO PROVIDE SLOPE AWAY FROM BUILDING AT 1/4”PER 1 FOOT MINIMUM. STRUCTURAL GENERAL NOTES STRUCTURAL LOADING DATA ROOF LOAD DEAD LOAD 20 psf LIVE LOAD 30 psf (per ARTICLE XXIV, 24.3-10) FLOOR SLAB ON GRADE LIVE LOAD 60 PCF (PER APPENDIX 8) SNOW LOAD GROUND SNOW LOAD Pg 20 psf IMPORTANCE FACTOR Is 1.0 SNOW EXPOSURE FACTOR Ce 1.0 SNOW THERMAL FACTOR Ct 1.0 FLAT ROOF SNOW LOAD Pf 20 psf WIND LOADS LESS THAN 50 FT. TALL, 20 LBS PER SQ. FT. (PER C.C.B.E.O. 24.4-1) MWFRS BASIC WIND SPEED 90 mph (3 SEC GUST) IMPORTANCE FACTOR Iw 1.0 OCCUPANCY CATEGORY II WIND EXPOSURE C INTERNAL PRESSURE COEFFICIENT +/-.18 COMPONENTS & CLADDING ROOF RAFTERS (>50 SQUARE FEET TRIBUTARY AREA) ROOF ZONE 1 +10/-17 psf ROOF ZONE 2 +10/-23 psf ROOF ZONE 3 +10/-27 psf WOOD DECK (TRIBUTARY AREA 10 SQUARE FEET) ROOF ZONE 1 +10/-17 psf ROOF ZONE 2 +10/-23 psf ROOF ZONE 3 +10/-27 psf WALLS (TRIBUTARY AREA > 30 SQUARE FEET) WALL ZONE 4 +17/-18 psf WALL ZONE 5 +17/-21 psf SEISMIC LOADS OCCUPANCY CATEGORY II SEISMIC IMPORTANCE FACTOR 1.0 Ss .17 S1 .082 SITE CLASS D Sds .182 Sd1 .131 SEISMIC DESIGN CATEGORY B BASIC SEISMIC FORCE RESISTING SYSTEM: INTERMEDIATE REINF MASONRY SHEAR WALLS SEISMIC RESPONSE COEFFICEINT Cs .06 RESPONSE MODIFICATION FACTOR R 3.5 ANALYSIS PROCEDURE EQUIVALENT LATERAL FORCE SYSTEM GENERAL THE CONTRACTOR SHALL VERIFY IN THE FIELD ALL EXISTING CONDITIONS (THE SITE) INCLUDING ALL DIMENSIONS AND ELEVATIONS. THE CONTRACTOR SHALL IMMEDIATELY NOTIFY THE ARCHITECT OF ANY DISCREPANCIES BETWEEN THE EXISTING SITE CONDITIONS AND THE DESIGN DOCUMENTS. REFERENCE MUST BE MADE TO ALL BID DOCUMENTS AS WELL AS THESE SPECIFICATIONS. THE CONTRACTOR SHALL COORDINATE WITH THE MECHANICAL AND ARCHITECTURAL DRAWINGS AND WITH THE MECHANCIAL CONTRACTOR, THE LOCATION OF ALL MECHANCIAL EQUIPMENT. THE CONTRACTOR SHALL NOTIFY THE ARCHITECT IF THE WEIGHT OF MECHANICAL UNITS ETC. ARE DIFFERENT FROM THE WEIGHTS POSTED ON THE DESIGN DRAWINGS. DISCREPANCIES SHALL BE RESOLVED BEFORE PROCEEDING WITH CONSTRUCTION. THE CONTRACTOR SHALL NOTIFY THE ARCHITECT/ENGINEER IMMEDIATELY OF ANY DISCREPANCIES TO AVOID THE POSSIBILITY OF UNNECESSARY FUTURE PROBLEMS AND POSSIBLE FIELD ORDERS. FAILURE TO DO SO WILL PUT THE FULL RESPONSIBILITY OF CORRECTION ON THE CONTRACTOR. THE CONTRACTOR SHALL COORDINATE THE WORK OF ALL TRADES AND MAKE NECESSARY INVESTIGATIONS AND FIELD MEASUREMENTS. DO NOT SCALE DRAWINGS. THE STRUCTURAL ENGINEER AND ARCHITECT HAS NO SUPERVISORY RESPONSIBLITY, HAS NO CONTROL OF OR RESPONSIBLITIY FOR THE MEANS, METHODS, TECHNIQUES, PROCEDURES OR SEQUENCE OF CONSTRCUCTION, HAS NO RESPONSIBILITY FOR THE FAILURE OF ANY CONTRACTOR TO PERFORM THE WORK IN ACCORDANCE WITH THE DESIGN DOCUMENTS AND NO RESPONSIBILITY TO DEVISE, IMPLEMENT OR ENFORCE ANY SAFETY PRECAUTIONS OR PROGRAMS FOR THE PROJECT. EXCAVATION STRIP TOPSOIL OVER THE ENTIRE BUILDING AREA. EXCAVATE AS REQUIRED FOR FOUNDING OF FOOTINGS ON UNDISTURBED SOIL OR COMPACTED ENGINEERED FILL OF 2,000 PSF NET BEARING CAPACITY. FOOTINGS SHALL BEAR AT SUFFICIENT DEPTH TO PROVIDE ADEQUATE FROST COVERAGE PER LOCAL REQUIREMENTS. IN NO CASE SHALL DEPTHS BE LESS THAN THE MINIMUM DEPTHS SHOWN ON PLANS AND DETAILS. THE STRUCTURE IS DESIGNED FOR WARM WEATHER USE ONLY; THEREFORE ALL FOUNDATION WALLS INCLUDING INTERIOR WALLS MUST EXTEND TO THE FROST DEPTH. REFER TO MECHANICAL DRAWINGS. MAINTAIN ALL EXCAVATIONS FREE OF WATER CONTINUOUSLY. BACKFILL BEHIND EXTERIOR WALLS ON THE OUTSIDE OF THE BUILDING WITH COMPACTED GRANULAR FILL PLACED IN 10" LOOSE LIFTS COMPACTED TO 85% OF MAXIMUM DENSITY. BACKFILL ON INSIDE OF BUILDING WITH COMPACTED GRANULAR FILL PLACED IN 10" LOOSE LIFTS COMPACTED TO 95% OF MAXIMUM DENSITY. CONCRETE GENERAL REQUIREMENTS ALL WORK SHALL CONFORM TO ALL REQUIREMENTS OF ACI 301-02, SPECIFICATION FOR STRUCTURAL CONCRETE, EXCEPT AS MODIFIED BY THE REQUIREMENTS OF THE CONTRACT DOCUMENTS. SUBMITTALS CONCRETE MIXES WITH HISTORICAL TEST DATA. MATERIAL CERTIFICATES: CEMENT, AGGREGATES, ADMIXTURES, REINFORCING STEEL REINFORCING STEEL PLACEMENT DRAWINGS EXECUTION CONCRETE COVER CONCRETE CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH = 3" CONCRETE EXPOSED TO EARTH OR WEATHER = 2" CONCRETE NOT EXPOSED TO WEATHER = 1-1/2" ALL FOOTINGS AND WALL FOOTINGS SHALL BE FORMED UNLESS NOTED. LAP SPLICE LENGTHS PER ACI 318 CHAPTER 12 USING A CLASS B SPLICE. ALL WELDED WIRE FABRIC SHALL BE LAPPED ONE GRID MINIMUM. ALL SLAB-ON-GRADE CONSTRUCTION JOINTS SHALL BE KEYED; REINFORCING SHALL NOT PASS THROUGH; 24 HOURS MINIMUM BETWEEN ADJACENT POURS. LOCATE JOINTS AS SHOWN ON PLANS; WHERE NOT SHOWN, CONTROL OR CONSTRUCTION JOINTS SHALL BE PLACED IN ACCORDANCE WITH ACI RECOMMENDATIONS I.E., A MAXIMUM PANEL SIZE (IN FEET) EQUAL TO APPROXIMATELY THREE TIMES THE THICKNESS OF THE SLAB (IN INCHES) IN BOTH DIRECTIONS. HOOK ENDS OF BARS INTERRUPTED BY OPENINGS. HOOK TOP BARS AT ALL EDGES. AT ALL WALL AND SLAB OPENINGS, PROVIDE 2-#5 BARS X OPENING WIDTH PLUS 4 FEET (2 FEET EACH SIDE) EACH FACE, UNLESS SHOWN OTHERWISE. PLACEMENT OF CONCRETE IN COLD WEATHER SHALL COMPLY WITH ACI306. PLACEMENT OF CONCRETE IN HOT WEATHER SHALL COMPLY WITH ACI305. TOLERANCES SHALL MEET ACI 117, ACI 301 AND ACI 318 AS A MINIMUM. MASONRY BEARING AND PARTITION WALLS GENERAL MASONRY CONSTRUCTION AND MATERIALS, INCLUDING COMPOSITION, QUALITY, STORAGE, HANDLING, PREPARATION AND PLACEMENT OF MATERIALS, QUALITY ASSURANCE FOR MATERIALS AND MASONRY, AND CONSTRUCTION OF MASONRY SHALL COMPLY TO ALL REQUIREMENTS OF "SPECIFICATIONS FOR MASONRY STRUCTURES" (ACI 530.1/ASCE 6/TMS 602) EXCEPT AS MODIFIED BY THE FOLLOWING NOTES. 1. FULL ALLOWABLE STRESSES WERE USED FOR THE ASD DESIGN OF THE MASONRY. 2. THEREFORE ALL MASONRY WORK SHALL BE INSPECTED AND QUALITY ASSURANCE 3. MEASURES WILL BE IMPLEMENTED. 4. DEFINITIONS (SEE ACI 530.1) 5. REFERENCES (SEE ACI 530.1) 6. COMPRESSIVE STRENGTH OF MASONRY F'M SHALL BE 1,350 PSI. (MINIMU SUBMITTALS MIX DESIGNS AND TEST RESULTS FOR MORTAR TO COMPLY WITH ASTM C270. MIX DESIGNS AND TEST RESULTS FOR GROUT TO COMPLY WITH ASTM C476. MATERIAL CERTIFICATES: REINFORCING STEEL, ANCHORS, TIES, MASONRY UNITS, MORTARAND GROUT MATERIALS QUALITY ASSURANCE TESTING AGENCY SHALL COMPLY WITH THE REQUIREMENTS OF ASTM C 1093. MATERIALS MORTAR SHALL CONFORM TO ASTM C270 TYPE S PORTLAND CEMENT TYPE 1 OR 2, LOW ALKALI PER ASTM C150 NON AIR ENTRAINED OR HYDRATED LIME PER ASTM C207 TYPE S. MORTAR SHALL BE NATURALLY PIGMENTED AND CONTAIN WATER REPELLANT ADMIXTURE AT ALL EXTERIOR WALLS. GROUT SHALL CONFORM TO ASTM C476 WITH A COMPRESSIVE STRENGTH OF 3,000 PSI AT 28 DAYS. MASONRY UNITS NORMAL WEIGHT 2 CELLS PER ASTM C90 TYPE I OR TYPE II AT INTERIOR WALLS. PROVIDE CONCRETE BRICK AND SPLITFACE MASONRY AT EXTERIOR WALLS AS SPECIFIED ELSEWHERE ON THIS SHEET. REINFORCING STEEL PER ASTM A 615. JOINT REINFORCING PER ASTM A 951. WELDED WIRE FABRIC PER ASTM A185. ANCHOR BOLTS HEADED ASTM A307. ACCESSORIES (SEE ACI 530.1) MIXING (SEE ACI 530.1) FABRICATION ALL LINTELS AND STEEL CONSTRUCTION ADJACENT TO OR ABUTTING MASONRY SHALL BE PROVIDED WITH GALVANIZED MASONRY TIES AT 16" O.C. PROVIDE 5/8" DIAMETER X 4" STUDS @ 32" O.C. ON TOP OF ALL WIDE FLANGE AND CHANNEL LINTELS. EXECUTION INSPECTION (SEE ACI 530.1) PREPARATION DO NOT WET CONCRETE MASONRY UNITS BEFORE LAYING. REINFORCEMENT: PLACE REINFORCEMENT IN GROUT SPACES WITH REBAR POSITIONERS PRIOR TO PLACING GROUT. REINFORCEMENT SPLICES SHALL BE LAPPED 48 TIMES THE BAR DIAMETER BUT NOT LESS THAN18". MASONRY ERECTION CONSTRUCT MASONRY IN RUNNING BOND UNLESS NOTED. ALL MASONRY SHALL BE FULL BEDDED IN MORTAR (FACE AND WEBS). TOOL BOTH SIDES OF ALL MORTAR JOINTS. ALL MASONRY LOCATED BELOW GRADE SHALL BE GROUTED SOLID. PROVIDE CONTINUOUS GALVANIZED, HORIZONTAL MASONRY REINFORCING AT 16" ON CENTER (ALTERNATE CMU COURSES) MINIMUM. UNDER ALL BEAM AND JOIST BEARINGS, FILL UNITS 2 CMU COURSES DEEP X 32" WIDE MINIMUM. PROVIDE A CONTINUOUS BOND BEAM UNDER ALL JOIST BEARINGS, AT ALL SILLS, AT TOPS OF ALL WALLS AND 8'-0" O.C. VERTICAL. PROVIDE A MINIMUM OF 2 -#5 VERTICAL BARS FOR THE FULL HEIGHT OF MASONRY WALLS AT ENDS OF WALLS, EACH SIDE OF OPENINGS AND EACH SIDE OF CONTROL JOINTS UNLESS NOTED. PROVIDE VERTICAL CONTROL JOINTS AT A MINIMUM SPACING OF 1-1/2 TIMES THE HEIGHT OF THE WALL OR 20'-0" WHICHEVER IS LESS. REFER TO ARCHITECTURAL DRAWINGS. ALL OPENINGS IN MASONRY WALLS SHALL HAVE BOND BEAMS. DIMENSIONAL LUMBER ALL WOOD CONSTRUCTION SHALL CONFORM TO THE "NATIONAL DESIGN SPECIFICATION FOR WOOD CONSTRUCTION -ASD" LATEST EDITION. STRUCTURAL WOOD SHALL BE CEDAR @ 19% MAX. M.C. WITH MINIMUM IN GRADE STRESS VALUES AS FOLLOWS: Beams/posts < 5”wide DF No 2 or better Fb = 850 psi Fv=180 psi E= 1,600 ksi Posts >= 5”x5 DF No 1 OR BETTER Fb = 1200 psi Fv=170 psi E= 1,600 ksi ALL WOOD IN CONTACT WITH MASONRY OR CONCRETE SHALL BE TREATED. ALL NAILS SHALL BE COMMON NAILS (6d -2" LONG .113" SHANK DIA; 8d -2-1/2" LONG .131 SHANK DIA; 10d -3" LONG .148" SHANK DIA; 16d -3-1/2" LONG .162" SHANK DIA.). LEAD HOLES SHALL BE PRE DRILLED FOR ALL LAG SCREWS PER NDS REQUIREMENTS. SLEEVES, ANCHORAGES, OPENINGS, ETC. IN GENERAL, STRUCTURAL DRAWINGS DO NOT SHOW EQUIPMENT PADS, DRAINS, HOLES, ANCHORAGES, INSERTS AND SLEEVES FOR ITEMS PASSING THROUGH OR ATTACHED TO CONCRETE OR FRAMING. REFER TO ARCHITECTURAL, MECHANICAL, AND ELECTRICAL DRAWINGS. ADJUST EQUIPMENT PADS AND SUBFRAMING TO FIT EQUIPMENT FURNISHED. PROVIDE SUBFRAMING FOR EQUIPMENT SUPPORTED ON OR SUSPENDED FROM THE STRUCTURE. STRUCTURAL STABILITY AND CONSTRUCTION INDIVIDUAL STRUCTURAL COMPONENTS ARE DESIGNED TO SUPPORT LOADS IN THEIR FINAL ERECTED POSITION AS PART OF THE TOTAL COMPLETED STRUCTURE. PROVIDE TEMPORARY GUYING AND BRACING AS REQUIRED UNTIL ALL CONSTRUCTION AFFECTING LATERAL STABILITY IS COMPLETED. CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR STABILITY OF STRUCTURE, ITS PARTS AND JOB SITE SAFETY BY USE OF GUYING, BRACING, SHORING, BARRICADES, SAFETY RAILINGS AND DEVICES DURING THE ENTIRE PERIOD OF CONSTRUCTION. SHOP DRAWINGS AND TEST REPORTS GENERAL CONTRACTOR SHALL CHECK ALL SHOP DRAWINGS BEFORE SUBMITTAL TO ARCHITECT/ENGINEER FOR REVIEW. REVIEW BY ARCHITECT/ENGINEER WILL BE FOR CONFORMANCE TO GENERAL LAYOUT AND DESIGN INTENT ONLY. CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR ACCURACY OF DIMENSIONS, FABRICATION, FIT UP OF PARTS AND BILLS OF MATERIALS. CONTRACTOR SHALL COORDINATE WORK OF VARIOUS TRADES AND MAKE NECESSARY FIELD MEASUREMENTS. THE CONTRACT SPECIFICATIONS PROVIDE A COMPLETE LISTING OF SUBMITTALS. THE FOLLOWING IS A SUMMARY OF THE REQUIRED SUBMITTALS: CONCRETE PRODUCT DATA SHEETS PROPOSED CONCRETE MIX DESIGNS WITH ASSOCIATED HISTORICAL TEST DATA. MATERIAL CERTIFICATIONS REINFORCING STEEL PLACEMENT DRAWINGS PER ACI 315 FIELD QUALITY CONTROL TESTS: SLUMP, AIR CONTENT, COMPRESSIVE STRENGTH ETC. MASONRY PRODUCT DATA SHEETS MATERIAL CERTIFICATIONS REINFORCING STEEL PLACEMENT DRAWINGS WOOD PRODUCTS (WOOD TRUSSES/ENGINEERED WOOD PRODUCTS) PRODUCT DATA SHEETS MATERIAL CERTIFICATIONS SHOP DRAWINGS DESIGN CALCULATIONS SIGNED AND SEALED BY PROFESSIONAL ENGINEER. °STRUCTURAL TESTS AND INSPECTIONS ALL TESTS AND INSPECTIONS SHALL BE PERFORMED BY AN INDEPENDENT TESTING AND INSPECTION AGENCY. THE SPECIAL INSPECTOR SHALL OBSERVE THE WORK ASSIGNED FOR CONFORMANCE TO THE APPROVED DESIGN DRAWINGS AND SPECIFICATIONS. THE SPECIAL INSPECTOR SHALL FURNISH INSPECTION REPORTS TO THE BUILDING OFFICIAL AND THE ENGINEER OF RECORD OR ARCHITECT OF RECORD. ALL DISCREPANCIES SHALL BE IMMEDIATELY BROUGHT TO THE ATTENTION OF THE CONTRACTOR FOR CORRECTION. IF UNCORRECTED, THE SPECIAL INSPECTOR SHALL NOTIFY THE BUILDING OFFICIAL AND THE ENGINEER OR ARCHITECT OF RECORD. THE SPECIAL INSPECTOR SHALL SUBMIT A FINAL REPORT STATING WHETHER THE WORK REQUIRING SPECIAL INSPECTION WAS IN CONFORMANCE WITH THE APPROVED PLANS AND SPECIFICATIONS AND THE APPLICABLE WORKMANSHIP PROVISIONS OF THIS CODE. JOB SITE VISITS BY THE STRUCTURAL ENGINEER OF RECORD DOES NOT CONSTITUTE AN OFFICIAL SPECIAL INSPECTION. THE FOLLOWING LIST OF MATERIALS AND WORK REQUIRE SPECIAL INSPECTIONS CONCRETE REINFORCING STEEL PLACEMENT BOLTS IN CONCRETE VERIFY CONCRETE MIX SAMPLE AND TEST CONCRETE PER ACI REQUIREMENTS CONCRETE PLACEMENT INSPECT AND MAINTENANCE OF CURING TECHNIQUES MASONRY SITE PREPARATION OF MORTAR & GROUT LOCATION OF REINFORCING SIZE GRADE AND PLACEMENT OF REINFORCING TYPE SIZE AND PLACEMENT OF ANCHORS GROUT SPACE CLEAN PLACEMENT OF GROUT CONSTRUCTION OF MORTAR JOINTS COMPLIANCE WITH CONSTRUCTION DOCUMENTS WOOD VERIFICATION OF GRADE, SIZE, SPECIES OF MATERIALS VERIFICATION OF NAILING, ROOF DIAPHRAGM VERIFICATION OF HOLDDOWNS MASONRY 1. PROVIDE INTEGRALLY COLORED GROUND FACE CONCRETE MASONRY UNITS IN 8" X 8" X 16" NOMINAL SIZE AT THE EXTERIOR WALLS. FINISHED SIDE TO FACE ROOM INTERIOR. INCLUDE INTEGRAL WATER REPELLANT ADMIXTURE. ACCEPTABLE MANUFACTURERS: NORTHFIELD BLOCK COMPANY/TRENWYTH GROUND FACE UNITS. 2. GENERAL MASONRY NOTES: PROVIDE BOND BEAMS TO MATCH THE CONCRETE BRICK STYLE. INTERIOR WALLS TO BE CONSTRUCTED OF INTEGRALLY COLORED GROUND FACE CONCRETE MASONRY UNITS IN 8" X 8" X 16" NOMINAL SIZE ALL JOINTS TO BE TOOLED BOTH SIDES. BOTH FACES OF CMU TO HAVE GROUND FACE FINISH. 3.MASONRY WALL CONSTRUCTION SHALL BE CLEANED THOROUGHLY AFTER MORTAR IS SET AND CURED. CLEAN MASONRY WITH A PROPRIETARY ACIDIC CLEANER EQUIVALENT TO SURE KLEAN CONCRETE BRICK CLEANER AS MANUFACTURED BY PROSOCO, INC. APPLY PER THE MANUFACTURER'S RECOMMENDATIONS AND AS FOLLOWS: USE A SOFT- FIBERED, TAMPICO MASONRY WASHING BRUSH OR WITH LOW -PRESSURE SPRAY EQUIPMENT (50 PSI MAX) FITTED WITH ACID-RESISTANT HOSES AND GASKETS. DO NOT USE PRESSURE SPRAY ABOVE 50 PSI. 5.GENERAL MASONRY NOTES: PROVIDE BOND BEAMS TO MATCH THE CONCRETE BRICK STYLE. INTERIOR WALLS TO BE CONSTRUCTED OF INTEGRALLY COLORED GROUND FACE CONCRETE MASONRY UNITS IN 8" X 8" X 16" NOMINAL SIZE ALL JOINTS TO BE TOOLED BOTH SIDES. BOTH FACES OF CMU TO HAVE GROUND FACE FINISH. 7.AFTER CLEANING, PROVIDE ONE COAT OF SURE KLEAN WEATHER SEAL BLOK-GUARD AND GRAFFITI CONTROL AS MANUFACTURED BY PROSOCO, INC. TO THE ENTIRE EXTENT OF THE EXTERIOR MASONRY WALL CONSTRUCTION. THIS PRODUCT IS A CLEAR, SOLVENT-BASED SILICONE ELASTOMER FORMULATED TO WEATHERPROOF CONCRETE BLOCK AND OTHER POROUS MASONRY MATERIALS SUCH AS CONCRETE BRICK. APPLY PER THE MANUFACTURER'S RECOMMENDATIONS AND AS FOLLOWS: USE BRUSH, ROLLER, OR LOW-PRESSURE SPRAY. FIT SPRAY EQUIPMENT WITH STAINLESS STEEL OR BRASS FITTINGS AND GASKETS SUITABLE FOR SOLVENT SOLUTIONS. 8.GENERAL NOTE: ALL ELECTRICAL CONDUIT SHALL BE CONCEALED WITHIN THE MASONRY CELLS. CODE REVIEW NOTES ·ADOPTED CODES: 2014 INDIANA BUILDING CODE 2009 ANSI A117.1 2009 INDIANA ELECTRICAL CODE 2012 INDIANA PLUMBING CODE ·BUILDING CLASSIFICATION: CLASS J. UNCLASSIFIED BUILDINGS AND STRUCTURES. ·TYPE OF CONSTRUCTION: TYPE IVB. ORDINARY MASONRY CONSTRUCTION. (0 HOUR FIRE RATING PER TABLE 20.8). ·PER TABLE 20.5, EXTERIOR WALLS MUST BE CONSTRUCTED TO MEET A 2- HOUR FIRE RESISTANCE RATING. PROVIDE A 2-HOUR FIRE RESISTANCE RATING, U.L. DESIGN U-905. DESCRIPTION FOLLOWS: PROJECT SPECIFICATIONS PRODUCTS REINFORCING BARS: ASTM A615 GRADE 60 REINFORCING BARS WELDABLE: ASTM A706 GRADE 60 PLAIN WIRE FABRIC: ASTM A185 PORTLAND CEMENT: ASTM C150 TYPE I OR II. AGGREGATES: ASTM C33 WATER: POTABLE ASTM C94 ADMIXTURES AIR ENTRAINING ASTM C260 CHEMICAL ADMIXTURES ASTM C 494 AIR CONTENT FOR CONCRETE EXPOSED TO WEATHER: 4 TO 7%. SLUMP: 4" CONCRETE STRENGTH: F'C 4,000 PSI AT 28 DAYS MIXING PER ASTM C94 CURING COMPOUNDS: ASTM C309 OR C1315 90% CONSTRUCTION DOCUMENTS 06/01/2020 100% REVIEW 06/19/2020 ISSUED FOR BID 07/14/2020 . ISSUED FOR REV DATE DESIGN DEVELOPMENT 02/05/2020 07/14/2020