Loading...
HomeMy WebLinkAboutWanee, Alex ESS Solar Drawings - 06.02.2020 (1)BLP BATINVACDUMMSP 26 0 ' - 0 " 221'-5"93'-2"82'-2"8'-0"85'-7"5'-11"107'-10"REVSHEET NAMESHEET SIZESHEET NUMBERNELSON A WANEE RESIDENCE 934 PRESTON DR., INDIANAPOLIS, IN 46280ANSI B11" X 17"DATEDESCRIPTIONREVISIONSSignature with SealPROJECT NAME & ADDRESSPV-1POWER HOME SOLAR, LLC "POWER YOUR FUTURE" 919 N. MAIN ST. MOORESVILLE, NC 28115 Phone: 704-800-6591 (OFFICE) Email: info@powerhome.com Web: www.powerhome.comDATE: 06/02/2020123PROJECT DESCRIPTION:SHEET INDEXPV-1PLOT PLAN & VICINITY MAPPV-2ROOF PLAN & MODULESPV-2ASTRING LAYOUTPV-3ATTACHMENT DETAILPV-4ELECTRICAL LINE DIAGRAMPV-5WIRING CALCULATIONSPV-6 to 12EQUIPMENT SPECIFICATIONSPLOT PLAN & VICINITY MAPHOUSE PHOTOVICINITY MAPSCALE: 1/25"=1'-0"PV-1SCALE: NTSPV-1PV-1SCALE: NTSPROJECT SITEPLOT PLAN & VICINITY MAP21 X 320 SILFAB SOLAR SIL-320 BL (320 W) MODULESROOF MOUNTED SOLAR PHOTOVOLTAIC MODULESEQUIPMENT SUMMARY21SILFAB SOLAR SIL-320 BL (320 W) MODULES04GENERAC PV LINK S2502 POWER OPTIMIZERS01GENERAC PWRCELL X7602 7600W INVERTERAUTHORITIES HAVING JURISDICTIONBUILDING: HAMILTON COUNTYZONING: HAMILTON COUNTYUTILITY: DUKE ENERGYPROJECT SITEDESIGN SPECIFICATIONSOCCUPANCY: IICONSTRUCTION: SINGLE-FAMILYZONING: RESIDENTIALGROUND SNOW LOAD: SEE STRUCTURAL LETTERWIND EXPOSURE: SEE STRUCTURAL LETTERWIND SPEED: SEE STRUCTURAL LETTERAPPLICABLE CODES & STANDARDSIRC 2020NEC 2008SYSTEM SIZE:6.72 kW DC STCARRAY AREA: ROOF#1 - 183.00 SQ FTARRAY AREA: ROOF#2 - 109.80 SQ FTARRAY AREA: ROOF#3 - 91.50 SQ FTROOF #2(06) SILFAB SOLAR SIL-320 BL (320 W)MODULESROOF #3(05) SILFAB SOLAR SIL-320 BL (320 W)MODULES(E) POOLPR O P E R T Y L I N E TREESPRESTON DR.1-STORY HOUSE(E) MAIN SERVICE PANEL(E) DRIVEWAY(E) DETACHED STRUCTUREROOF #1(10) SILFAB SOLAR SIL-320 BL (320 W) MODULESPR O P E R T Y L I N E (E) POOL BLP BATINVACDUMMSP SDSD SDSAF27'-2"9'-11"3'-0"17'-10"3'-0"36'-0"16'-7"3'-0"17'-11"3'-0"36'-0"16'-10"9'-8"18' - 8 " 6'- 0 "2'-4"2'-4"4'-8"REVSHEET NAMESHEET SIZESHEET NUMBERNELSON A WANEE RESIDENCE 934 PRESTON DR., INDIANAPOLIS, IN 46280ANSI B11" X 17"DATEDESCRIPTIONREVISIONSSignature with SealPROJECT NAME & ADDRESSPV-2POWER HOME SOLAR, LLC "POWER YOUR FUTURE" 919 N. MAIN ST. MOORESVILLE, NC 28115 Phone: 704-800-6591 (OFFICE) Email: info@powerhome.com Web: www.powerhome.comDATE: 06/02/2020MODULE TYPE, DIMENSIONS & WEIGHT1ROOF PLAN & MODULESPV-2LEGEND- SOLADECKSDINVMSP- INVERTER- MAIN SERVICE PANEL- VENT, ATTIC FAN (ROOF OBSTRUCTION)- ROOF ATTACHMENT- RAFTERS- CONDUITACD- AC DISCONNECTROOF PLAN &MODULESNUMBER OF MODULES = 21 MODULESMODULE TYPE = SILFAB SOLAR SIL-320 BL (320 W) MODULESMODULE WEIGHT = 43 LBS / 19.5 KG.MODULE DIMENSIONS = 66.92"x 39.37" = 18.30 SFUNIT WEIGHT OF ARRAY = 2.35 PSFSAFNOTES:·THE LOCATION OF THE SAF SHOULD BEDETERMINED ON SITE.·THE SAF SHOULD BE LOCATED 30"-36" FROM THEPEAK OF THE ROOF OR ABOUT 5 ROWS DOWNFROM THE RIDGE.·THE SAF SHOULD NOT BE MOUNTED ON ANYSTRUCTURAL MEMBER LIKE TRUSS/RAFTER.·"CAN VENTS" CAN BE REPLACED BY SAF.·SAF CANNOT BE MOUNTED ON A METAL ROOF.PLEASE CARRY GABLE VENT FANS FOR METALROOF INSTALLATION (IF APPLICABLE).SOLAR ATTIC FAN66.92"39.37"SILFAB SOLARSIL-320 BL(320 W)320 WATTSCALE: 1/14"=1'-0"ROOF DESCRIPTIONROOF TYPECOMPOSITIONSHINGLEROOFROOFTILTAZIMUTHFRAMINGSIZEFRAMINGSPACING#114.04°206°SEE STRUCTURALLETTER#214.04°206°#314.04°114°- BACKUP LOAD PANELBLP- BATTERYBAT- PV LINK OPTIMIZEROP- RAPID SHUTDOWN(E)BACK OF RESIDENCE(E)FRONT OF RESIDENCEROOF #1TILT - 14.04°AZIM. - 206°ROOF #2TILT - 14.04°AZIM. - 206°ROOF #3TILT - 14.04°AZIM. - 114°(N) SOLADECK(N) 3/4" EMT CONDUIT(N) GENERAC PWRCELL X7602 7600W INVERTER(N) FUSED AC DISCONNECT(E) UTILITY METER(E) MAIN SERVICE PANELSOLAR ATTIC FAN(LOCATION TBD ON SITE)(N) BACKUP LOAD PANEL(N) GENERAC PWRCELL9 BATTERY(N) GENERAC SNAP RS801 RS DEVICEPRESTON DR.ROOF #2(06) SILFAB SOLAR SIL-320 BL (320 W) MODULESROOF #1(10) SILFAB SOLAR SIL-320 BL (320 W) MODULESROOF #3(05) SILFAB SOLAR SIL-320 BL (320 W)MODULESARRAY AREA & ROOF AREA CALC'SROOF# OFMODULESARRAYAREA(Sq. Ft.)ROOFAREA(Sq. Ft.)ROOFAREACOVEREDBY ARRAY(%)#110183.00974.4419#206109.80336.3533#30591.50336.1727 BLP BATINVACDUMMSP SDSD SDOPOPOPOP REVSHEET NAMESHEET SIZESHEET NUMBERNELSON A WANEE RESIDENCE 934 PRESTON DR., INDIANAPOLIS, IN 46280ANSI B11" X 17"DATEDESCRIPTIONREVISIONSSignature with SealPROJECT NAME & ADDRESSPV-2APOWER HOME SOLAR, LLC "POWER YOUR FUTURE" 919 N. MAIN ST. MOORESVILLE, NC 28115 Phone: 704-800-6591 (OFFICE) Email: info@powerhome.com Web: www.powerhome.comDATE: 06/02/20201ROOF PLAN WITH STRING LAYOUTPV-2ASCALE: 1/16" = 1'-0"STRINGLAYOUTBILL OF MATERIALSEQUIPMENTQTYDESCRIPTIONSOLAR PV MODULE21SILFAB SOLAR SIL-320 BL (320 W) MODULESOPTIMIZER04GENERAC PV LINK S2502 POWER OPTIMIZERSGENERAC SNAP RS21GENERAC SNAPRS MODEL RS801INVERTER01GENERAC PWRCELL X7602 7600W INVERTERAC DISCONNECT160A FUSED, (2) 40A FUSES, 240V, NEMA 3R, UL LISTEDSOLADECK3SOLADECKS 600 V, NEMA 3R, UL LISTEDBATTERY1GENERAC PWRCELL9 BATTERYBACKUP PANEL1125A, BACKUP PANEL, 240VRAILS14QRAIL LIGHT 14 FT. BLACKSPLICE KIT6QSPLICE INTERNAL LIGHTWEEB BMC4WEEB BMC MILLMODULE CLAMPS28UNIVERSAL MID CLAMPGROUNDING LUG7WEEB LUG W/ T-BOLTEND CLAMPS28UNIVERSAL END CLAMPSATTACHMENT61L-MOUNT ATTACHMENT (QUICKMOUNT)T-BOLT65T-BOLT W/ NUT M8 X 20MM(E)BACK OF RESIDENCEPRESTON DR.(E)FRONT OF RESIDENCE(N) PV LINK OPTIMIZER - 1(N) PV LINK OPTIMIZER - 2(N) PV LINK OPTIMIZER - 3(N) PV LINK OPTIMIZER - 4 REVSHEET NAMESHEET SIZESHEET NUMBERNELSON A WANEE RESIDENCE 934 PRESTON DR., INDIANAPOLIS, IN 46280ANSI B11" X 17"DATEDESCRIPTIONREVISIONSSignature with SealPROJECT NAME & ADDRESSPV-3POWER HOME SOLAR, LLC "POWER YOUR FUTURE" 919 N. MAIN ST. MOORESVILLE, NC 28115 Phone: 704-800-6591 (OFFICE) Email: info@powerhome.com Web: www.powerhome.comDATE: 06/02/2020ATTACHMENTDETAIL2ATTACHMENT DETAIL (enlarged view)21STRUCTURAL ATTACMENT (SIDE VIEW)PV-3SCALE: NTSPV-3SCALE: NTSPV MODULE(E) COMPOSITESHINGLE ROOFSEE (2/PV-3)FOR ENLARGEDVIEWSEE STRUCTURAL LETTERHEX HEAD5/16" X 4", 18-8 SSLAG SCREW9"X12" QUICK MOUNTL-MOUNT FLASHINGQUICK-MOUNT Q-RAILSQMR-RL14 (LIGHT)PV MODULEUNIVERSAL END/MID CLAMP(E) COMPOSITESHINGLE ROOFOFFSET L-FEETSEE STRUCTURAL LETTER SILFAB SOLAR SIL-320 BL (320 W) MODULES====-+++-++++---2-+-13==PVLINK SUBSTRING OPTIMIZER (S2502)RATED POWER : 2500WMPPT VOLTAGE RANGE: 60 TO 360 VMAX OUTPUT VOLTAGE: 420VMAX OUTPUT CURRENT: 8ARAPID SHUTDOWN COMPLIANTGROUND-FAULT PROTECTION COMPLIANTSNAP RS (RS801)MAX INPUT CURRENT - 13 AUL 1741 LISTEDMODULE LEVEL RAPIDSHUTDOWN (PVRSS)COMPLIANTNEMA 6P RATEDGENERACPOWERCOREJUNCTION BOX600 V, NEMA 3UL LISTED(E) MAIN BREAKER TOHOUSE 240 V, 200A/2P(TOP FED)NL2L1MLOADLINEGGNSUPPLY SIDE TAPREF NEC 230.82(6),705.12(A) FORSUPPLY SIDE TAPEXISTING GROUNDINGELECTRODE SYSTEMTO EARTHREF. NEC 250.52,250.53(A)GECPWRcell MODEL 9 BATTERY8.6 kWh, 5.0 kWGENERAC PWRCELL X7602 7600W INVERTER (240V)OUTPUT: 240V, 32A96.5% CEC WEIGHTED EFFICIENCYNEMA 3R RATED, UL 1741 LISTED, INTERNALGFDI WITH INTEGRATED DC DISCONNECT236GN50A/2-PAC LOAD CENTER, 125 ARATED, 240/120, 1-PHASE(50A/2-P MB)450A/2-P30A/2-P30A/2-P30A/2-P30A/2-PBACK UPLOADS UP TO40A CIRCUIT(E) COMMUNICATIONROUTER5AC DISCONNECT:60A FUSED, (2) 40A FUSES,240V NEMA 3R, UL LISTED--+++-++++---2-+-13==-1-+++-++++---2-+-1354--+++-++++---2-+-13-(E) MAIN SERVICEPANEL,SQUARE D 200A RATED, 240V655454REVSHEET NAMESHEET SIZESHEET NUMBERNELSON A WANEE RESIDENCE 934 PRESTON DR., INDIANAPOLIS, IN 46280ANSI B11" X 17"DATEDESCRIPTIONREVISIONSSignature with SealPROJECT NAME & ADDRESSPV-4POWER HOME SOLAR, LLC "POWER YOUR FUTURE" 919 N. MAIN ST. MOORESVILLE, NC 28115 Phone: 704-800-6591 (OFFICE) Email: info@powerhome.com Web: www.powerhome.comDATE: 06/02/2020ELECTRICAL LINEDIAGRAM1ELECTRICAL LINE DIAGRAMPV-4SCALE: NTSSERVICE INFOUTILITY PROVIDER:MAIN SERVICE VOLTAGE:MAIN PANEL BRAND:MAIN SERVICE PANEL:MAIN CIRCUIT BREAKER RATING:MAIN SERVICE LOCATION:SERVICE FEED SOURCE:DUKE ENERGY240V200A200ANORTH-WESTOVERHEADSQUARE DPV ARRAY +VE CONDUCTOR AND L1PV ARRAY -VE CONDUCTOR AND L2NEUTRAL CONDUCTOREGC AND GECSINGLE TWISTED PAIR, CAT 5 WIREWIRE LEGENDLABEL 7AT MEPLABEL 9AT UTILITY METERLABEL 8AT MEP! WARNING !DUAL POWER SOURCESSECOND SOURCE IS PV SYSTEM! CAUTION !SOLAR POINT OFINTERCONNECTION! WARNING !SOLAR SYSTEMCONNECTEDAND ENERGIZEDLABEL 10AT UTILITY METER! WARNING !THE SERVICE METER IS ALSO SERVEDBY A PHOTOVOLTAIC SYSTEMLABEL 3AT INVERTERLABEL 2AT INVERTERLABEL 4AT EACH DCDISCONNECTWARNING:PHOTOVOLTAICPOWER SOURCELABEL 1ON ALL CONDUITSSPACED AT MAX 10FTPHOTOVOLTAICDC DISCONNECT! CAUTION !SOLAR ELECTRICSYSTEM CONNECTEDAND ENERGIZED! CAUTION !PHOTOVOLTAIC SYSTEMEQUIPPED WITH RAPIDSHUTDOWNLABEL 5AT EACH ACDISCONNECT! WARNING !ELECTRIC SHOCK HAZARDDO NOT TOUCH TERMINALS.TERMINALS ON BOTH LINE AND LOAD SIDESMAY BE ENERGIZED IN THE OPEN POSITIONPHOTOVOLTAICACDISCONNECTLABEL 6AT EACH ACDISCONNECT(21) SILFAB SOLAR SIL-320 BL (320 W) MODULES(3) PV LINKS OF 05 MODULES &(1) PV LINK OF 06 MODULES CONNECTED IN SERIESQTYCONDUCTOR INFORMATIONCONDUIT TYPECONDUIT SIZE(8)#10AWG -PV WIRE/USE-2N/AN/A(1)#6AWG -BARE COPPER IN FREE AIR(4)#10AWG -THWN-2EMT OR FLEX INATTIC3/4"(1)#6AWG -THWN-2 GND(2)#10AWG -THWN-2EMT OR FLEX3/4"(1)#10AWG -THWN-2 GND(3)#6AWG -THWN-2EMT OR FLEX3/4"(1)#6AWG -THWN-2 GND(3)#6AWG -THWN-2EMT OR FLEX3/4"(1)#6AWG -THWN-2 GND(3)#6AWG -THWN-2EMT OR FLEX3/4"123456 REVSHEET NAMESHEET SIZESHEET NUMBERNELSON A WANEE RESIDENCE 934 PRESTON DR., INDIANAPOLIS, IN 46280ANSI B11" X 17"DATEDESCRIPTIONREVISIONSSignature with SealPROJECT NAME & ADDRESSPV-5POWER HOME SOLAR, LLC "POWER YOUR FUTURE" 919 N. MAIN ST. MOORESVILLE, NC 28115 Phone: 704-800-6591 (OFFICE) Email: info@powerhome.com Web: www.powerhome.comDATE: 06/02/2020WIRINGCALCULATIONSINVERTER SPECIFICATIONS MANUFACTURER / MODEL #GENERAC PWRCELLX7602 AC POWER OUTPUT (LOADS/GRID)7600VA AC POWER OUTPUT (BACKUP)8000VA NOMINAL OUTPUT VOLTAGE240 VAC MAX OUTPUT CURRENT @240V (LOADS/GRID)32A MAX OUTPUT CURRENT @240V (BACKUP)50A NOMINAL DC INPUT VOLTAGE380Vdc MAX DC INPUT VOLTAGE420Vdc CEC WEIGHTED EFFICIENCY96.5% MAX DC POWER (PV)10000W MAX INPUT CURRENT (PV)20Adc CONT. PEAK POWER (BATTERY)8000WSOLAR MODULE SPECIFICATIONS MANUFACTURER / MODEL #SILFAB SIL320-BL VMP33.85V IMP9.46A VOC41.9V ISC9.92A TEMP. COEFF. VOC-0.301%/°C MODULE DIMENSION66.92"L x 39.37"W x 1.49"D (In Inch) MODULE EFFICIENCY18.8%SERIES SUB STRING OPTIMIZER SPECIFICATIONS MANUFACTURER / MODEL #PV LINK S2502 RATED POWER2500W MPPT VOLTAGE RANGE60-360 Vmp MAXIMUM INPUT VOLTAGE420Voc MAXIMUM OUTPUT420 Adc NOMINAL OUTPUT380 Vdc MAXIMUM OUTPUT CURRENT8 A MAXIMUM SHORT CIRCUIT CURRENT18 ABATTERY SPECIFICATIONS MANUFACTURER / MODEL #GENERAC PWRCELLBATTERY USABLE ENERGY8.6kW RATED CONTINUOUS POWER3.4Kw POWER: 60 MINUTES4.2kW POWER: 2 MINUTES5.0kW REBUS VOLTAGE: INPUT/ OUTPUT360-420Vdc MODULE VOLTAGE46.8Vdc ROUND-TRIP EFFICIENCY96.5%AMBIENT TEMPERATURE SPECS RECORD LOW TEMP-11° AMBIENT TEMP (HIGH TEMP 2%)34° CONDUIT HEIGHT0.5" ROOF TOP TEMP56°No. OF INVERTERNO. OF CURRENT CARRYING CONDUCTORSCONDUIT FILL CORRECTION PER NEC TABLE 310.15(B)(3)(a)CIRCUIT CONDUCTOR SIZE16 AWG3TEMP. CORRECTION PER NEC TABLE 310.15(B)(2)(a)0.9675AEXPECTED WIRE TEMP (In Celsius)34REQUIRED CIRCUIT CONDUCTOR AMPACITY PER NEC 690.8(A&B)1.25 X INVERTER OUTPUT CURRENT (BACKUP POWER)42.5ADERATED AMPACITY OF CIRCUIT CONDUCTOR72AResult should be greater than (42.5A) otherwise less the entry for circuit conductor sizeand ampacityAC CONDUCTOR AMPACITY CALCULATIONS:FROM INVERTER TO BACK-UP PANEL:AC CONDUCTOR AMPACITY CALCULATIONS:FROM INVERTER TO MEP:1CIRCUIT CONDUCTOR AMPACITY PER NEC TABLE 310.15(B)(16)TEMP. CORRECTION PER TABLE 310.15 (B)(2)(a) XCONDUIT FILL CORRECTION PER NEC 310.15(B)(3)(a) XCIRCUIT CONDUCTOR AMPACITY 310.15 (B)(16)No. OF INVERTERNO. OF CURRENT CARRYING CONDUCTORSCONDUIT FILL CORRECTION PER NEC TABLE 310.15(B)(3)(a)CIRCUIT CONDUCTOR SIZE16 AWG3TEMP. CORRECTION PER NEC TABLE 310.15(B)(2)(a)0.9675AEXPECTED WIRE TEMP (In Celsius)34REQUIRED CIRCUIT CONDUCTOR AMPACITY PER NEC 690.8(A&B)1.25 X MAX INVERTER OUTPUT CURRENT (LOADS/GRID)40ADERATED AMPACITY OF CIRCUIT CONDUCTOR72AResult should be greater than (40A) otherwise less the entry for circuit conductor size andampacity1CIRCUIT CONDUCTOR AMPACITY PER NEC TABLE 310.15(B)(16)TEMP. CORRECTION PER TABLE 310.15 (B)(2)(a) XCONDUIT FILL CORRECTION PER NEC 310.15(B)(3)(a) XCIRCUIT CONDUCTOR AMPACITY 310.15 (B)(16)DC CONDUCTOR AMPACITY CALCULATIONS:ARRAY TO JUNCTION BOX:FROM JUNCTION BOX TO INVERTER:FROM BATTERY TO INVERTER:EXPECTED WIRE TEMP (In Celsius)NO. OF CURRENT CARRYING CONDUCTORSCONDUIT FILL CORRECTION PER NEC TABLE 310.15(B)(3)(a)CIRCUIT CONDUCTOR SIZE0.710 AWG856TEMP. CORRECTION PER NEC TABLE 310.15 (B)(2)(a)0.71CIRCUIT CONDUCTOR AMPACITY PER NEC TABLE 310.15(B)(16)40AREQUIRED CIRCUIT CONDUCTOR AMPACITY PER NEC 690.8(A&B)1.25 X Imax10ADERATED AMPACITY OF CIRCUIT CONDUCTORTEMP. CORRECTION PER TABLE 310.15 (B)(2)(a) XCONDUIT FILL CORRECTION PER NEC 310.15(B)(3)(a) XCIRCUIT CONDUCTOR AMPACITY 310.15 (B)(16)19.88AResult should be greater than (10A) otherwise less the entry for circuit conductor size andampacityEXPECTED WIRE TEMP (In Celsius)NO. OF CURRENT CARRYING CONDUCTORSCONDUIT FILL CORRECTION PER NEC TABLE 310.15(B)(3)(a)CIRCUIT CONDUCTOR SIZE0.810 AWG456TEMP. CORRECTION PER NEC TABLE 310.15 (B)(2)(a)0.71CIRCUIT CONDUCTOR AMPACITY PER NEC TABLE 310.15(B)(16)40AREQUIRED CIRCUIT CONDUCTOR AMPACITY PER NEC 690.8(A&B)1.25 X Imax X # of PV LINKS20ADERATED AMPACITY OF CIRCUIT CONDUCTORTEMP. CORRECTION PER TABLE 310.15 (B)(2)(a) XCONDUIT FILL CORRECTION PER NEC 310.15(B)(3)(a) XCIRCUIT CONDUCTOR AMPACITY 310.15 (B)(16)22.72AResult should be greater than (20A) otherwise less the entry for circuit conductor size andampacityEXPECTED WIRE TEMP (In Celsius)NO. OF CURRENT CARRYING CONDUCTORSCONDUIT FILL CORRECTION PER NEC TABLE 310.15(B)(3)(a)CIRCUIT CONDUCTOR SIZE110 AWG234TEMP. CORRECTION PER NEC TABLE 310.15 (B)(2)(a)0.96CIRCUIT CONDUCTOR AMPACITY PER NEC TABLE310.15(B)(16)40AREQUIRED CIRCUIT CONDUCTOR AMPACITY PER NEC 690.8(A&B)1.25 X Imax26.25ADERATED AMPACITY OF CIRCUIT CONDUCTORTEMP. CORRECTION PER TABLE 310.15 (B)(2)(a) XCONDUIT FILL CORRECTION PER NEC 310.15(B)(3)(a) XCIRCUIT CONDUCTOR AMPACITY 310.15 (B)(16)38.40AResult should be greater than (26.25A) otherwise less the entry for circuit conductor sizeand ampacity REVSHEET NAMESHEET SIZESHEET NUMBERNELSON A WANEE RESIDENCE 934 PRESTON DR., INDIANAPOLIS, IN 46280ANSI B11" X 17"DATEDESCRIPTIONREVISIONSSignature with SealPROJECT NAME & ADDRESSPV-6POWER HOME SOLAR, LLC "POWER YOUR FUTURE" 919 N. MAIN ST. MOORESVILLE, NC 28115 Phone: 704-800-6591 (OFFICE) Email: info@powerhome.com Web: www.powerhome.comDATE: 06/02/2020EQUIPMENTSPECIFICATION REVSHEET NAMESHEET SIZESHEET NUMBERNELSON A WANEE RESIDENCE 934 PRESTON DR., INDIANAPOLIS, IN 46280ANSI B11" X 17"DATEDESCRIPTIONREVISIONSSignature with SealPROJECT NAME & ADDRESSPV-7POWER HOME SOLAR, LLC "POWER YOUR FUTURE" 919 N. MAIN ST. MOORESVILLE, NC 28115 Phone: 704-800-6591 (OFFICE) Email: info@powerhome.com Web: www.powerhome.comDATE: 06/02/2020EQUIPMENTSPECIFICATION REVSHEET NAMESHEET SIZESHEET NUMBERNELSON A WANEE RESIDENCE 934 PRESTON DR., INDIANAPOLIS, IN 46280ANSI B11" X 17"DATEDESCRIPTIONREVISIONSSignature with SealPROJECT NAME & ADDRESSPV-8POWER HOME SOLAR, LLC "POWER YOUR FUTURE" 919 N. MAIN ST. MOORESVILLE, NC 28115 Phone: 704-800-6591 (OFFICE) Email: info@powerhome.com Web: www.powerhome.comDATE: 06/02/2020EQUIPMENTSPECIFICATION REVSHEET NAMESHEET SIZESHEET NUMBERNELSON A WANEE RESIDENCE 934 PRESTON DR., INDIANAPOLIS, IN 46280ANSI B11" X 17"DATEDESCRIPTIONREVISIONSSignature with SealPROJECT NAME & ADDRESSPV-9POWER HOME SOLAR, LLC "POWER YOUR FUTURE" 919 N. MAIN ST. MOORESVILLE, NC 28115 Phone: 704-800-6591 (OFFICE) Email: info@powerhome.com Web: www.powerhome.comDATE: 06/02/2020EQUIPMENTSPECIFICATION REVSHEET NAMESHEET SIZESHEET NUMBERNELSON A WANEE RESIDENCE 934 PRESTON DR., INDIANAPOLIS, IN 46280ANSI B11" X 17"DATEDESCRIPTIONREVISIONSSignature with SealPROJECT NAME & ADDRESSPV-10POWER HOME SOLAR, LLC "POWER YOUR FUTURE" 919 N. MAIN ST. MOORESVILLE, NC 28115 Phone: 704-800-6591 (OFFICE) Email: info@powerhome.com Web: www.powerhome.comDATE: 06/02/2020EQUIPMENTSPECIFICATION REVSHEET NAMESHEET SIZESHEET NUMBERNELSON A WANEE RESIDENCE 934 PRESTON DR., INDIANAPOLIS, IN 46280ANSI B11" X 17"DATEDESCRIPTIONREVISIONSSignature with SealPROJECT NAME & ADDRESSPV-10APOWER HOME SOLAR, LLC "POWER YOUR FUTURE" 919 N. MAIN ST. MOORESVILLE, NC 28115 Phone: 704-800-6591 (OFFICE) Email: info@powerhome.com Web: www.powerhome.comDATE: 06/02/2020EQUIPMENTSPECIFICATION REVSHEET NAMESHEET SIZESHEET NUMBERNELSON A WANEE RESIDENCE 934 PRESTON DR., INDIANAPOLIS, IN 46280ANSI B11" X 17"DATEDESCRIPTIONREVISIONSSignature with SealPROJECT NAME & ADDRESSPV-11POWER HOME SOLAR, LLC "POWER YOUR FUTURE" 919 N. MAIN ST. MOORESVILLE, NC 28115 Phone: 704-800-6591 (OFFICE) Email: info@powerhome.com Web: www.powerhome.comDATE: 06/02/2020EQUIPMENTSPECIFICATION REVSHEET NAMESHEET SIZESHEET NUMBERNELSON A WANEE RESIDENCE 934 PRESTON DR., INDIANAPOLIS, IN 46280ANSI B11" X 17"DATEDESCRIPTIONREVISIONSSignature with SealPROJECT NAME & ADDRESSPV-11APOWER HOME SOLAR, LLC "POWER YOUR FUTURE" 919 N. MAIN ST. MOORESVILLE, NC 28115 Phone: 704-800-6591 (OFFICE) Email: info@powerhome.com Web: www.powerhome.comDATE: 06/02/2020EQUIPMENTSPECIFICATION REVSHEET NAMESHEET SIZESHEET NUMBERNELSON A WANEE RESIDENCE 934 PRESTON DR., INDIANAPOLIS, IN 46280ANSI B11" X 17"DATEDESCRIPTIONREVISIONSSignature with SealPROJECT NAME & ADDRESSPV-11BPOWER HOME SOLAR, LLC "POWER YOUR FUTURE" 919 N. MAIN ST. MOORESVILLE, NC 28115 Phone: 704-800-6591 (OFFICE) Email: info@powerhome.com Web: www.powerhome.comDATE: 06/02/2020EQUIPMENTSPECIFICATION REVSHEET NAMESHEET SIZESHEET NUMBERNELSON A WANEE RESIDENCE 934 PRESTON DR., INDIANAPOLIS, IN 46280ANSI B11" X 17"DATEDESCRIPTIONREVISIONSSignature with SealPROJECT NAME & ADDRESSPV-12POWER HOME SOLAR, LLC "POWER YOUR FUTURE" 919 N. MAIN ST. MOORESVILLE, NC 28115 Phone: 704-800-6591 (OFFICE) Email: info@powerhome.com Web: www.powerhome.comDATE: 06/02/2020EQUIPMENTSPECIFICATION