PERMIT PACK 5680 Garrett Gregory-S
SHEET INDEXPV1 - COVER SHEETPV2 - PROPERTY PLANPV3 - SITE PLANPV4 - EQUIPMENT & ATTACHMENT DETAILPV5 - ELECTRICAL SINGLE LINE DIAGRAMPV6 - ELECTRICAL CALCULATIONS & ELECTRICAL NOTESPV7 - MAIN BREAKER DERATE CALCS.(IF NEEDED)PV8 - LABELS & LOCATIONSPV9 - CUSTOM DIRECTORY PLACARD(IF NEEDED - NEC 690.56(B))GENERAL NOTESSITE SPECIFICATIONSOCCUPANCY - R3CONSTRUCTION - V-BZONING: RESIDENTIALSCOPE OF WORKINSTALLATION OF UTILITY INTERACTIVE PHOTOVOLTAIC SOLAR SYSTEM6.72 kW DC PHOTOVOLTAIC SOLAR ARRAYROOF TYPE: Comp ShingleMODULES: (21) Trina 320INVERTER(S): Enphase IQ7 Microinverters,----RACKING: Unirac SFM InfinityAERIAL VIEWSITE NOTES / OSHA REGULATION1. A LADDER SHALL BE IN PLACE FOR INSPECTION IN COMPLIANCE WITH OSHA REGULATIONS.2. THE PV MODULES ARE CONSIDERED NON-COMBUSTIBLE AND THIS SYSTEM IS AN UTILITYINTERACTIVE SYSTEM WITH NO STORAGE BATTERIES.3. THE SOLAR PV INSTALLATION SHALL NOT OBSTRUCT ANY PLUMBING, MECHANICAL, ORBUILDING ROOF VENTS.4. ROOF COVERINGS SHALL BE DESIGNED, INSTALLED, AND MAINTAINED IN ACCORDANCE WITHTHIS CODE AND THE APPROVED MANUFACTURER'S INSTRUCTIONS SUCH THAT THE ROOFCOVERING SHALL SERVE TO PROTECT THE BUILDING OR STRUCTURE.SOLAR CONTRACTOR1. MODULE CERTIFICATIONS WILL INCLUDE UL1703, IEC61646, IEC61730.2. IF APPLICABLE, MODULE GROUNDING LUGS MUST BE INSTALLED AT THE MARKED GROUNDINGLUG HOLES PER THE MANUFACTURERS' INSTALLATION REQUIREMENTS.3. AS INDICATED BY DESIGN, OTHER NRTL LISTED MODULE GROUNDING DEVICES MAY BE USEDIN PLACE OF STANDARD GROUNDING LUGS AS SHOWN IN MANUFACTURER DOCUMENTATIONAND APPROVED BY THE AHJ.4. CONDUIT AND WIRE SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS AND ARENOT MEANT TO LIMIT UP-SIZING AS REQUIRED BY FIELD CONDITIONS.5. CONDUIT POINT OF PENETRATION FROM EXTERIOR TO INTERIOR TO BE INSTALLED ANDSEALED WITH A SUITABLE SEALING COMPOUND.6. DC WIRING LIMITED TO MODULE FOOTPRINT W/ ENPHASE AC SYSTEM.7. ENPHASE WIRING SYSTEMS SHALL BE LOCATED AND SECURED UNDER THE ARRAY W/SUITABLE WIRING CLIPS.8. MAX DC VOLTAGE CALCULATED USING MANUFACTURER PROVIDED TEMP COEFFICIENT FORVOC UNLESS NOT AVAILABLE.9. ALL INVERTERS, MOTOR GENERATORS, PHOTOVOLTAIC MODULES, PHOTOVOLTAIC PANELS,AC PHOTOVOLTAIC MODULES, DC COMBINERS, DC-TO-DC CONVERTERS,SOURCE CIRCUITCOMBINERS, AND CHARGE CONTROLLERS INTENDED FOR USE IN A PHOTOVOLTAIC POWER SYSTEMWILL BE IDENTIFIED AND LISTED FOR THE APPLICATION PER 690.4 (B).10. ALL SIGNAGE TO BE PLACED IN ACCORDANCE WITH LOCAL BUILDING CODE.11. TERMINALS AND LUGS WILL BE TIGHTENED TO MANUFACTURER TORQUE SPECIFICATIONS (WHENPROVIDED) IN ACCORDANCE WITH NEC CODE 110.14(D) ON ALL ELECTRICAL CONNECTIONS.EQUIPMENT LOCATIONS1. PROPER ACCESS AND WORKING CLEARANCE AROUND EXISTING AND PROPOSED ELECTRICALEQUIPMENT WILL BE PROVIDED AS PER SECTION [NEC 110.26].2. EQUIPMENT INSTALLED IN DIRECT SUNLIGHT MUST BE RATED FOR EXPECTED OPERATINGTEMPERATURE AS SPECIFIED BY [NEC 690.31 (A)-(B)] AND [NEC TABLE 310.15 (B)].3. ADDITIONAL AC DISCONNECTS SHALL BE PROVIDED WHERE THE INVERTER IS NOT ADJACENTTO THE UTILITY AC DISCONNECT, OR NOT WITHIN SIGHT OF THE UTILITY AC DISCONNECT.4. ALL EQUIPMENT SHALL BE INSTALLED ACCESSIBLE TO QUALIFIED PERSONNEL ACCORDING TONEC APPLICABLE CODES.5. ALL COMPONENTS ARE LISTED FOR THEIR PURPOSE AND RATED FOR OUTDOOR USAGE WHENAPPROPRIATE.DATEDRAWING BYPROJECT NUMBERSHEET NAMEPAGE NUMBER REVISIONCONFIDENTIAL - THE INFORMATIONHEREIN CONTAINED SHALL NOT BEUSED FOR THE BENEFIT OFANYONE EXCEPTBLUERAVENSOLAR NOR SHALL ITBE DISCLOSED IN WHOLE OR INPART TO OTHERS OUTSIDERECIPIENTS ORGANIZATION,EXCEPT IN CONNEC TION WITH THESALE AND USE OF THE RESPECTIVEEQUIPMENT, WITHOUT THEWRITTEN PERMISSION OFBLUERAVENSOLAR LLC.PV1COVER SHEETAlan Ruiz76978815May 21, 2020----SITE INFORMATION: Garrett Gregory 11367 Zanardi Ct Zionsville, Indiana 46077 DC SYSTEM SIZE: CONTRACTOR:BRS FIELD OPS385.498.6700PV INSTALLATIONPROFESSIONALScott Gurney# PV-011719-015866NABCEPCERTIFIED1403 N RESEARCH WAY, BUILDING JOREM, UT 84097800-377-4480WWW.BLUERAVENSOLAR.COMCODES AND STANDARDS1. ALL WORK SHALL COMPLY WITH 2009 Indiana Electric Code, 2012 INTERNATIONAL BUILDINGCODE (IBC), 2018 INTERNATIONAL RESIDENTIAL CODE (IRC), 2006 INTERNATIONAL PLUMBINGCODE (IPC), AND ALL STATE AND LOCAL BUILDING, ELECTRICAL, AND PLUMBING CODES.2. DRAWINGS HAVE BEEN DETAILED ACCORDING TO UL LISTING REQUIREMENTS.DESIGN CRITERIAWIND SPEED: 115 MPH GROUND SNOW LOAD: 20 PSF WIND EXPOSURE FACTOR: C SEISMIC DESIGN CATEGORY: B NDCACDCACDCACDCACDCACDCACDCACDCACDCACDCACDCACDCACDCACDCACDCACDCACDCACDCACDCACDCACDCAC11367 Zanardi CtFRONT OF HOME8'16'SCALE: 1/16" = 1'-0"0'32'4'LEGENDACMINVERTER & DC DISCONNECTINVAC DISCONNECTUTILITY METERPV REVENUE METERJBJUNCTION BOXPROPERTY LINEFIRE SETBACKEMT CONDUIT RUN(TO BE DETERMINED IN FIELD)PV WIRE STRINGPVSUB(E)SUBPANELLC(N)LOAD CENTERCCOMBINER BOX/AGGREGATORMSPMAIN SERVICE PANELTSTRANSFER SWITCHDATEDRAWING BYPROJECT NUMBERSHEET NAMEPAGE NUMBERREVISIONCONFIDENTIAL - THE INFORMATIONHEREIN CONTAINED SHALL NOT BEUSED FOR THE BENEFIT OFANYONE EXCEPTBLUERAVENSOLAR NOR SHALL ITBE DISCLOSED IN WHOLE OR INPART TO OTHERS OUTSIDERECIPIENTS ORGANIZATION,EXCEPT IN CONNEC TION WITH THESALE AND USE OF THE RESPECTIVEEQUIPMENT, WITHOUT THEWRITTEN PERMISSION OFBLUERAVENSOLAR LLC.PV2PROPERTY PLAN----Alan Ruiz76978815May 21, 2020SITE INFORMATION: Garrett Gregory 11367 Zanardi Ct Zionsville, Indiana 46077 DC SYSTEM SIZE: 6.72 kW DC CONTRACTOR:BRS FIELD OPS385.498.6700PV INSTALLATIONPROFESSIONALScott Gurney# PV-011719-015866NABCEPCERTIFIED1403 N RESEARCH WAY, BUILDING JOREM, UT 84097800-377-4480WWW.BLUERAVENSOLAR.COM NDCACDCACDCACDCACDCACDCACDCACDCACDCACDCACDCACDCACDCACDCACDCACDCACDCACDCACDCACDCACDCACFRONT OF HOME4'8'SCALE: 1/8" = 1'-0"0'2'16'LEGENDACMINVERTER & DC DISCONNECTINVAC DISCONNECTUTILITY METERPV REVENUE METERJBJUNCTION BOXPROPERTY LINEFIRE SETBACKEMT CONDUIT RUN(TO BE DETERMINED IN FIELD)PV WIRE STRINGPVSUB(E)SUBPANELLC(N)LOAD CENTERCCOMBINER BOX/AGGREGATORMSPMAIN SERVICE PANELTSTRANSFER SWITCHDATEDRAWING BYPROJECT NUMBERSHEET NAMEPAGE NUMBERREVISIONCONFIDENTIAL - THE INFORMATIONHEREIN CONTAINED SHALL NOT BEUSED FOR THE BENEFIT OFANYONE EXCEPTBLUERAVENSOLAR NOR SHALL ITBE DISCLOSED IN WHOLE OR INPART TO OTHERS OUTSIDERECIPIENTS ORGANIZATION,EXCEPT IN CONNEC TION WITH THESALE AND USE OF THE RESPECTIVEEQUIPMENT, WITHOUT THEWRITTEN PERMISSION OFBLUERAVENSOLAR LLC.Alan Ruiz76978815May 21, 2020SITE INFORMATION: Garrett Gregory 11367 Zanardi Ct Zionsville, Indiana 46077 CONTRACTOR:BRS FIELD OPS385.498.6700PV INSTALLATIONPROFESSIONALScott Gurney# PV-011719-015866NABCEPCERTIFIEDPV3SITE PLAN----1403 N RESEARCH WAY, BUILDING JOREM, UT 84097800-377-4480WWW.BLUERAVENSOLAR.COMMP1# OF MODULES: 21AZIMUTH:179°PITCH:32°TSRF:96%AREA: 658.97 SQ. FT MODULEWIDTHHPV4ARRAY DETAIL, FRONT VIEWScale: 3/8" = 1'-0"MODULEWIDTH48" MAX.1'-11"MAX.32°72" MAX.1'-11"MAX.ARRAY DETAIL, SIDE VIEWScale: 3/8" = 1'-0"LANDSCAPEPORTRAITLANDSCAPEPORTRAITUnirac SFM Infinity TRIM RAILPV MODULE (BEHIND TRIM RAIL)GPV4Unirac SFM Infinity FRAMESFM Infinity Switchblade FlashkitRACKING ATTACHMENTS TO BESTAGGERED BY SHIFTING EACHSUBSEQUENT ROW OF ATTACHMENTSONE RAFTER OVER.(E) ROOFMEMBRANEUNIRAC SLIDERS ANDTRIMRAIL ROOF ATTACHMENTSPV MODULE(E) BUILDINGSTRUCTUREDETAIL, BOTTOM STANDOFFScale: 3" = 1'-0"G Trina 3205/16" STAINLESS STEEL LAG BOLTWITH 2-1/2" MIN. EMBEDMENTAND FLAT WASHER2.5"Unirac SFM InfinityUNIRAC TRIMRAIL2.5" MIN. EMBED.FLASHING(E) ROOFMEMBRANEUNIRAC SLIDERSPV MODULE(E) BUILDINGSTRUCTURETrina 3205/16" STAINLESS STEEL LAG BOLTWITH 2-1/2" MIN. EMBEDMENTAND FLAT WASHER2.5"Unirac SFM InfinityFLASHINGDETAIL, MIDDLE/TOP STANDOFFScale: 3" = 1'-0"H 2.5" MIN. EMBED.ROOF TYPE: Comp ShingleROOF FRAMING TYPE: Manufactured TrussRAFTER OR TOP CHORD(TRUSS) 2x4 @ 24"O.C.CEILING JOIST OR BOTTOM CHORD(TRUSS) 2x4 @ 24"O.C.PV ARRAY INFORMATIONPV MODULE COUNT:21 MODULES# OF ATTACHMENT POINTS:24ARRAY AREA:Module Count x 17.51ft² = 367.7ft²ROOF AREA:2368.5ft²% OF ARRAY/ROOF:15.5%ARRAY WEIGHT:Module Count x 50lbs = 1050.0lbsDISTRIBUTED LOAD:Array Weight ÷ Array Area = 2.86 lbs/ft²POINT LOAD:Array Weight ÷ Attachments = 43.8lbs/attachmentDATEDRAWING BYPROJECT NUMBERSHEET NAMEPAGE NUMBERREVISIONCONFIDENTIAL - THE INFORMATIONHEREIN CONTAINED SHALL NOT BEUSED FOR THE BENEFIT OFANYONE EXCEPTBLUERAVENSOLAR NOR SHALL ITBE DISCLOSED IN WHOLE OR INPART TO OTHERS OUTSIDERECIPIENTS ORGANIZATION,EXCEPT IN CONNEC TION WITH THESALE AND USE OF THE RESPECTIVEEQUIPMENT, WITHOUT THEWRITTEN PERMISSION OFBLUERAVENSOLAR LLC.Alan Ruiz76978815May 21, 2020SITE INFORMATION: Garrett Gregory 11367 Zanardi Ct Zionsville, Indiana 46077 CONTRACTOR:BRS FIELD OPS385.498.6700PV INSTALLATIONPROFESSIONALScott Gurney# PV-011719-015866NABCEPCERTIFIEDPV4EQUIP. DETAIL----1403 N RESEARCH WAY, BUILDING JOREM, UT 84097800-377-4480WWW.BLUERAVENSOLAR.COM (E)LOADSNG(E)200A / 2PNEGCL2L1(N)30A/2P(E)200A MAIN SERVICE PANEL(E)200A / 2P MAIN BREAKERNEGCL2L115(E)GROUNDINGELECTRODE (S)INTERCONNECTION NOTES1. ONE OF THE METHODS THAT FOLLOWS SHALL BE USED TO DETERMINE THE RATINGS OFBUSBARS AND PANELBOARDS. (a) THE SUM OF 125 PERCENT OF THE INVERTER(S) OUTPUTCIRCUIT CURRENT AND THE RATING OF THE OVERCURRENT DEVICE PROTECTING THEBUSBAR SHALL NOT EXCEED THE AMPACITY OF THE BUS BAR. (b) WHERE TWO SOURCES,ONE THE UTILITY AND THE OTHER AN INVERTER ARE LOCATED AT OPPOSITE ENDS OF ABUSBAR THAT CONTAINS LOADS, THE SUM OF 125 PERCENT OF THE INVERTER(S) OUTPUTCIRCUIT CURRENT AND THE RATING OF THE OVERCURRENT DEVICE PROTECTING THEBUSBAR SHALL NOT EXCEED 120 PERCENT OF THE AMPACITY OF THE BUSBAR [NEC 705.12].DISCONNECT NOTES1. DISCONNECTING SWITCHES SHALL BE WIRED SUCH THAT WHEN THE SWITCH ISOPENED THE CONDUCTORS REMAINING LIVE ARE CONNECTED TO THETERMINALS MARKED “LINE SIDE” (TYPICALLY THE UPPER TERMINALS)2. AC DISCONNECT MUST BE ACCESSIBLE TO QUALIFIED UTILITY PERSONNEL, BELOCKABLE, AND BE A VISIBLE-BREAK SWITCHPV BREAKER TO BE LOCATED OPPOSITEEND OF BUSSING FROM MAIN BREAKERPV AC DISCONNECTNON- FUSEDLOCKABLE, VISIBLE OPEN30A, 240V, 2-POLE120/240 VAC 60HZ1 PHASETO UTILITYGRID(E)L1NL2NGGL2L1(N)20A/2P21L1L2G21JUNCTION BOXL1L2G(1)CIRCUITOF 11 MODULES(N)20A/2PL2L1L1L2GJUNCTION BOX(OPTIONAL IF UF-BCABLE USED FORENTIRE HOMERUN)L1L2G3GJUNCTION BOX(1)CIRCUITOF 10 MODULES+-+-++--++--+-+-++--++--(21) Trina 320UL 1703 COMPLIANT(21) Enphase IQ7 Microinverters MICROINVERTERSUL 1741 COMPLIANT5 MODULES MAX FOR ALL SUB-BRANCHCIRCUIT(S) TO COMPLY WITH VRISE CALCSEnphase IQ Combiner 3X-IQ-AM1-240-3(SOLAR LOADS ONLY)DATEDRAWING BYPROJECT NUMBERSHEET NAMEPAGE NUMBERREVISIONCONFIDENTIAL - THE INFORMATIONHEREIN CONTAINED SHALL NOT BEUSED FOR THE BENEFIT OFANYONE EXCEPTBLUERAVENSOLAR NOR SHALL ITBE DISCLOSED IN WHOLE OR INPART TO OTHERS OUTSIDERECIPIENTS ORGANIZATION,EXCEPT IN CONNEC TION WITH THESALE AND USE OF THE RESPECTIVEEQUIPMENT, WITHOUT THEWRITTEN PERMISSION OFBLUERAVENSOLAR LLC.Alan Ruiz76978815May 21, 2020SITE INFORMATION: Garrett Gregory 11367 Zanardi Ct Zionsville, Indiana 46077 DC SYSTEM SIZE: 6.72 kW DC CONTRACTOR:BRS FIELD OPS385.498.6700PV INSTALLATIONPROFESSIONALScott Gurney# PV-011719-015866NABCEPCERTIFIEDPV5ELEC. 3 LINE DIAG.----1403 N RESEARCH WAY, BUILDING JOREM, UT 84097800-377-4480WWW.BLUERAVENSOLAR.COMPANEL WATTAGE : 320WAC SYSTEM SIZE: (6.72 KW - 21 MODULES) DATEDRAWING BYPROJECT NUMBERSHEET NAMEPAGE NUMBERREVISIONCONFIDENTIAL - THE INFORMATIONHEREIN CONTAINED SHALL NOT BEUSED FOR THE BENEFIT OFANYONE EXCEPTBLUERAVENSOLAR NOR SHALL ITBE DISCLOSED IN WHOLE OR INPART TO OTHERS OUTSIDERECIPIENTS ORGANIZATION,EXCEPT IN CONNEC TION WITH THESALE AND USE OF THE RESPECTIVEEQUIPMENT, WITHOUT THEWRITTEN PERMISSION OFBLUERAVENSOLAR LLC.Alan Ruiz76978815May 21, 2020SITE INFORMATION: Garrett Gregory 11367 Zanardi Ct Zionsville, Indiana 46077 DC SYSTEM SIZE: 6.72 kW DC CONTRACTOR:BRS FIELD OPS385.498.6700PV INSTALLATIONPROFESSIONALScott Gurney# PV-011719-015866NABCEPCERTIFIEDPV6ELEC. CALCS.----1403 N RESEARCH WAY, BUILDING JOREM, UT 84097800-377-4480WWW.BLUERAVENSOLAR.COMGROUNDING NOTES1. A GROUNDING ELECTRODE SYSTEM IN ACCORDANCE WITH [NEC 690-47] AND[NEC 250-50] THROUGH [NEC 250-60] SHALL BE PROVIDED. PER NEC,GROUNDING ELECTRODE SYSTEM OF EXISTING BUILDING MAY BE USED ANDBONDED TO AT THE SERVICE ENTRANCE. IF EXISTING SYSTEM IS INACCESSIBLE,OR INADEQUATE, OR IS ONLY METALLIC WATER PIPING, A SUPPLEMENTALGROUNDING ELECTRODE WILL BE USED AT THE INVERTER LOCATIONCONSISTING OF A UL LISTED 8 FT GROUND ROD WITH ACORN CLAMP.2. THE GROUNDING ELECTRODE CONDUCTOR SHALL BE PROTECTED FROM PHYSICALDAMAGE BETWEEN THE GROUNDING ELECTRODE AND THE PANEL (OR INVERTER) IFSMALLER THAN #6 AWG COPPER WIRE PER NEC 250-64B. THE GROUNDING ELECTRODECONDUCTOR WILL BE CONTINUOUS, EXCEPT FOR SPLICES OR JOINTS AT BUSBARSWITHIN LISTED EQUIPMENT PER [NEC 250.64C.].3. GROUNDING ELECTRODE CONDUCTORS SHALL BE NO LESS THAN #8 AWG ANDNO GREATER THAN #6 AWG COPPER AND BONDED TO THE EXISTING GROUNDINGELECTRODE TO PROVIDE FOR A COMPLETE SYSTEM.4. PV SYSTEM SHALL BE GROUNDED IN ACCORDANCE TO [NEC 250.21], [NEC TABLE250.122],AND ALL METAL PARTS OR MODULE FRAMES ACCORDING TO [NEC690.46].5. MODULE SOURCE CIRCUITS SHALL BE GROUNDED IN ACCORDANCE TO [NEC690.42].6. THE GROUNDING CONNECTION TO A MODULE SHALL BE ARRANGED SUCH THATTHE REMOVAL OF A MODULE DOES NOT INTERRUPT A GROUNDED CONDUCTORTO ANOTHER MODULE.7. EACH MODULE WILL BE GROUNDED USING THE SUPPLIED CONNECTIONS POINTSIDENTIFIED IN THE MANUFACTURER'S INSTALLATION INSTRUCTIONS.8. ENCLOSURES SHALL BE PROPERLY PREPARED WITH REMOVAL OF PAINT/FINISHAS APPROPRIATE WHEN GROUNDING EQUIPMENT WITH TERMINATIONGROUNDING LUGS.9. GROUNDING SYSTEM COMPONENTS SHALL BE LISTED FOR THEIR PURPOSE, ANDGROUNDING DEVISES EXPOSED TO THE ELEMENTS SHALL BE RATED FOR DIRECT BURIAL.10. GROUNDING AND BONDING CONDUCTORS SHALL BE COPPER, SOLID ORSTRANDED, AND BARE WHEN EXPOSED.11. EQUIPMENT GROUNDING CONDUCTORS SHALL BE SIZE ACCORDING TO [NEC690.45]AND BE A MINIMUM OF #10AWG WHEN NOT EXPOSED TO DAMAGE (#6AWGSHALL BE USED WHEN EXPOSED TO DAMAGE).12. GROUNDING AND BONDING CONDUCTORS, IF INSULATED, SHALL BE COLORCODED GREEN (OR MARKED GREEN IF #4 AWG OR LARGER)13. ALL CONDUIT BETWEEN THE UTILITY AC DISCONNECT AND THE POINT OFCONNECTION SHALL HAVE GROUNDED BUSHINGS AT BOTH ENDS.14. SYSTEM GEC SIZED ACCORDING TO [NEC 690.47], [NEC TABLE 250.66], DCSYSTEM GEC SIZED ACCORDING TO [NEC 250.166], MINIMUM #8AWG WHENINSULATED, #6AWG WHEN EXPOSED TO DAMAGE.15. EXPOSED NON-CURRENT CARRYING METAL PARTS OF MODULE FRAMES,EQUIPMENTS, AND CONDUCTOR ENCLOSURES SHALL BE GROUNDED INACCORDANCE WITH 250.134 OR 250.136(A) REGARDLESS OF VOLTAGE.WIRING & CONDUIT NOTES1. ALL CONDUIT SIZES AND TYPES, SHALL BE LISTED FOR ITS PURPOSE ANDAPPROVED FOR THE SITE APPLICATIONS2. BOLTED CONNECTION REQUIRED IN DC DISCONNECTS ON THE WHITE GROUNDEDCONDUCTOR (USE POLARIS BLOCK OR NEUTRAL BAR)3. ANY CONNECTION ABOVE LIVE PARTS MUST BE WATERTIGHT. REDUCING WASHERSDISALLOWED ABOVE LIVE PARTS, MEYERS HUBS RECOMMENDED4. UV RESISTANT CABLE TIES(NOT ZIP TIES) USED FOR PERMANENT WIRE MANAGEMENTOFF THE ROOF SURFACE IN ACCORDANCE WITH NEC 110.2,110.3(A-B). 300.45. SOLADECK JUNCTION BOXES MOUNTED FLUSH W/ROOF SURFACE TO BE USED FORWIRE MANAGEMENT AND AS FLASHED ROOF PENETRATIONS FOR INTERIOR CONDUITRUNS.6. ALL PV CABLES AND HOMERUN WIRES BE TYPE USE-2, AND SINGLE-CONDUCTORCABLE LISTED AND IDENTIFIED AS PV WIRE, TYPE TC-ER, OR EQUIVALENT; ROUTED TOSOURCE CIRCUIT COMBINER BOXES AS REQUIRED7. ALL CONDUCTORS AND OCPD SIZES AND TYPES SPECIFIED ACCORDING TO [NEC690.8]FOR MULTIPLE CONDUCTORS8. ALL PV DC CONDUCTORS IN CONDUIT EXPOSED TO SUNLIGHT SHALL BE INSTALLEDAT LEAST 7/8" ABOVE THE ROOF SURFACE AND DERATED ACCORDING TO [NEC TABLE310.15 (B)(2)(a), NEC TABLE 310.15(B)(3)(a),& NEC 310.15(B)(3)(c)].9. EXPOSED ROOF PV DC CONDUCTORS SHALL BE USE-2, 90°C RATED, WET AND UVRESISTANT, AND UL LISTED RATED FOR 600V, UV RATED SPIRAL WRAP SHALL BEUSED TO PROTECT WIRE FROM SHARP EDGES10. PHASE AND NEUTRAL CONDUCTORS SHALL BE DUAL RATED THHN/THWN-2INSULATED, 90°C RATED, WET AND UV RESISTANT, RATED FOR 600V11. 4-WIRE DELTA CONNECTED SYSTEMS HAVE THE PHASE WITH THE HIGHERVOLTAGE TO GROUND MARKED ORANGE OR IDENTIFIED BY OTHER EFFECTIVE MEANS.12. ALL SOURCE CIRCUITS SHALL HAVE INDIVIDUAL SOURCE CIRCUIT PROTECTION13. VOLTAGE DROP LIMITED TO 2% FOR DC CIRCUITS AND 3% FOR AC CIRCUITS14. NEGATIVE GROUNDED SYSTEMS DC CONDUCTORS SHALL BE COLOR CODED ASFOLLOWS: DC POSITIVE- RED (OR MARKED RED), DC NEGATIVE- GREY (OR MARKED GREY)15. POSITIVE GROUNDED SYSTEMS DC CONDUCTORS COLOR CODED:DC POSITIVE- GREY (OR MARKED GREY), DC NEGATIVE- BLACK (OR MARKED BLACK)16. AC CONDUCTORS >4AWG COLOR CODED OR MARKED:PHASE A OR L1- BLACK, PHASE B OR L2- RED, PHASE C OR L3- BLUE, NEUTRAL-WHITE/GRAY* USE-2 IS NOT INDOOR RATED BUT PV CABLE IS RATED THWN/THWN-2 AND MAYBE USED INSIDE** USE-2 IS AVAILABLE AS UV WHITE17. RIGID CONDUIT, IF INSTALLED, (AND/OR NIPPLES) MUST HAVE A PULL BUSHING TOPROTECT WIRES.18. IF CONDUIT DETERMINED TO BE RAN THROUGH ATTIC IN FIELD THEN CONDUIT WILLBE EITHER EMT, FMC, OR MC CABLE IF DC CURRENT COMPLYING WITH NEC 690.31, NEC250.118(10). DISCONNECTING MEANS SHALL COMPLY WITH 690.13 AND 690.1519. CONDUIT RAN THROUGH ATTIC WILL BE AT LEAST 18" BELOW ROOF SURFACECOMPLYING WITH NEC 230.6(4) AND SECURED NO GREATER THAN 6' APART PER NEC330.30(B). LABEL 3IF THERE ARE TWO AC DISCONNECTS, TO BE PLACED ONDISCONNECT CLOSEST TO PV SYSTEM.AT POINT OF INTERCONNECTION, MARKED AT ACDISCONNECTING MEANS.[NEC 690.54, NEC 690.13 (B)]LABEL 4IF INTERCONNECTING ON THE LOAD SIDE, INSTALL THISLABEL ANYWHERE THAT IS POWERED BY BOTH THEUTILITY AND THE SOLAR PV SYSTEM: THE MAIN SERVICEPANEL AND SUB-PANELS.[NEC 705.12(B)(3)]LABEL 5PLACED ADJACENT TO THE BACK-FED BREAKERFROM THE INVERTER IF TIE IN CONSISTS OF LOADSIDE CONNECTION TO BUSBAR.[NEC 705.12(B)(2)(3)(b)]283105711157129ORLABEL 7AT DIRECT-CURRENT EXPOSED RACEWAYS, CABLE TRAYS, COVERS AND ENCLOSURES OFJUNCTION BOXES, AND OTHER WIRING METHODS; SPACED AT MAXIMUM 10FT SECTION ORWHERE SEPARATED BY ENCLOSURES, WALLS, PARTITIONS, CEILINGS, OR FLOORS.[NEC 690.31(G)(3&4)]LABEL 6(ONLY IF 3 OR MORE SUPPLY SOURCES TOA BUSBAR)SIGN LOCATED AT LOAD CENTER IF ITCONTAINS 3 OR MORE POWER SOURCES.[NEC 705.12(B)(2)(3)(C)]LABEL 10SIGN LOCATED AT RAPID SHUT DOWNDISCONNECT SWITCH [NEC 690.56(C)(3)].LABEL 8FOR PV SYSTEMS THAT SHUT DOWN THE ARRAYAND CONDUCTORS LEAVING THE ARRAY:SIGN TO BE LOCATED ON OR NO MORE THAN 3FT AWAY FROM SERVICE DISCONNECTINGMEANS TO WHICH THE PV SYSTEMS ARECONNECTED AND SHALL INDICATE THELOCATION OF ALL IDENTIFIED RAPID SHUTDOWNSWITCHES IF NOT AT THE SAME LOCATION.[NEC 690.56(C)(1)(A)]LABEL 9FOR PV SYSTEMS THAT ONLY SHUT DOWNCONDUCTORS LEAVING THE ARRAY:SIGN TO BE LOCATED ON OR NO MORE THAN 3FT AWAY FROM SERVICE DISCONNECTINGMEANS TO WHICH THE PV SYSTEMS ARECONNECTED AND SHALL INDICATE THELOCATION OF ALL IDENTIFIED RAPID SHUTDOWNSWITCHES IF NOT AT THE SAME LOCATION.[NEC 690.56(C)(1)(B)]LABEL 1FOR PV DISCONNECTING MEANS WHERE ALLTERMINALS OF THE DISCONNECTING MEANS MAY BEENERGIZED IN THE OPEN POSITION.[NEC 690.13(B), NEC 705.22]LABEL 2AT EACH DC DISCONNECTING MEANS, INCLUDING THEDC DISCONNECT AT THE INVERTER.[NEC 690.53, NEC 690.13(B)]LABEL 11SIGN LOCATED AT AC COMBINER BOX FORALL MICRO-INVERTER / AC MODULEINSTALLS (IF APPLICABLE).13LABELING NOTES:1.LABELS CALLED OUT ACCORDING TO ALL COMMON CONFIGURATIONS. ELECTRICIAN TODETERMINE EXACT REQUIREMENTS IN THE FIELD PER CURRENT NEC AND LOCAL CODES ANDMAKE APPROPRIATE ADJUSTMENTS.2.LABELING REQUIREMENTS BASED ON THE 2017 NATIONAL ELECTRIC CODE, OSHA STANDARD19010.145, ANSI Z535.3.MATERIAL BASED ON THE REQUIREMENTS OF THE AUTHORITY HAVING JURISDICTION.4.LABELS TO BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED ANDSHALL NOT BE HANDWRITTEN [NEC 110.21]5.LABELS TO BE A MINIMUM LETTER HEIGHT OF 3/8", WHITE ON RED BACKGROUND; REFLECTIVE,AND PERMANENTLY AFFIXED [IFC 605.11.1.1]1*ELECTRICAL DIAGRAMS SHOWN ABOVE IS FOR LABELING PURPOSES ONLY. NOT AN ACTUAL REPRESENATION OF EQUIPMENT AND CONNECTIONS TO BE INSTALLED. LABEL LOCATIONSPRESENTED MAY VERY DEPENDING ON TYPE OF INTERCONNECTION METHOD AND LOCATION PRESENTED ON PV5 OF 3 LINE DIAGRAM. PV5 LINE DIAGRAM TO REFLECT ACTUALREPRESENTATION OF PROPOSED SCOPE OF WORK.JUNCTION BOXOR COMBINER BOXMAIN SERVICE PANELEXISTING SUB PANEL(IF WHERE POINT OFINTERCONNECTIONIS MADE)PV COMBINERSUBPANEL -IF USED TO COMBINEPV OUTPUT CIRCUITSACDCINVERTER (S)INTEGRATED DC DISCONNECT(ONLY IF PVINTERCONNECTIONCONSISTS OF LOADSIDE BREAKER)(ONLY IF PVINTERCONNECTIONCONSISTS OF LOADSIDE BREAKER)LABELING DIAGRAM FOR STRING INV. / DC OPTIMIZER INV.:AC JUNCTION BOXOR AC COMBINER BOXMAIN SERVICE PANELEXISTING SUB PANEL(IF WHERE POINT OFINTERCONNECTIONIS MADE)PV COMBINERSUBPANEL -IF USED TO COMBINEPV OUTPUT CIRCUITS(ONLY IF PVINTERCONNECTIONCONSISTS OF LOADSIDE BREAKER)LABELING DIAGRAM FOR MICRO INV.:835611151213111 OR PLACARD1034IF BREAKER USED34IF BREAKER USEDAC DISCONNECT(IF REQ. / INSTALLED)AC DISCONNECT(IF REQ. / INSTALLED)334IF BREAKER USED34IF BREAKER USED&&&&611134LABEL 14PERMANENT DIRECTORY TO BE LOCATED ATSOLAR ARRAY RAPID SHUTDOWN SWITCHDENOTING THE LOCATION OF THE SERVICEEQUIPMENT LOCATION IF SOLAR ARRAY RAPIDSHUT DOWN DISCONNECT SWITCH IS NOTGROUPED AND WITHIN LINE OF SITE OF MAINSERVICE DISCONNECTING MEANS.[NEC 705.10]LABEL 15PERMANENT DIRECTORY TO BE LOCATED AT MAINSERVICE EQUIPMENT DENOTING THE LOCATIONOF THE PV RAPID SHUTDOWN SYSTEMDISCONNECTING MEANS IF SOLAR ARRAY RAPIDSHUT DOWN DISCONNECT SWITCH IS NOTGROUPED AND WITHIN LINE OF SITE OF MAINSERVICE DISCONNECTING MEANS. [NEC 705.10,NEC 690.56(C)(1)]LABEL 13PERMANENT DIRECTORY TO BE LOCATED ATMAIN SERVICE EQUIPMENT LOCATION IF ALLELECTRICAL POWER SOURCE DISCONNECTINGMEANS (SOLAR ARRAY RAPID SHUTDOWNSWITCH) ARE GROUPED AND IN LINE OF SITE OFMAIN SERVICE DISCONNECTING MEANS.[NEC 690.56(C) & NEC 705.10].1315 OR1515LABEL 12IF THERE ARE TWO DISCONNECTS, TO BEPLACED ON DISCONNECT CLOSEST TOUTILITYPLACARD TO BE PLACED AT ACDISCONNECT PER COLORADO SPRINGSUTILITY. OR PLACARD1315 ORSOLAR SYSTEMUTILITYAC DISCONNECTDATEDRAWING BYPROJECT NUMBERSHEET NAMEPAGE NUMBERREVISIONCONFIDENTIAL - THE INFORMATIONHEREIN CONTAINED SHALL NOT BEUSED FOR THE BENEFIT OFANYONE EXCEPTBLUERAVENSOLAR NOR SHALL ITBE DISCLOSED IN WHOLE OR INPART TO OTHERS OUTSIDERECIPIENTS ORGANIZATION,EXCEPT IN CONNEC TION WITH THESALE AND USE OF THE RESPECTIVEEQUIPMENT, WITHOUT THEWRITTEN PERMISSION OFBLUERAVENSOLAR LLC.Alan Ruiz76978815May 21, 2020SITE INFORMATION: Garrett Gregory 11367 Zanardi Ct Zionsville, Indiana 46077 DC SYSTEM SIZE: 6.72 kW DC CONTRACTOR:BRS FIELD OPS385.498.6700PV INSTALLATIONPROFESSIONALScott Gurney# PV-011719-015866NABCEPCERTIFIEDPV8LABELS----1403 N RESEARCH WAY, BUILDING JOREM, UT 84097800-377-4480WWW.BLUERAVENSOLAR.COM SHEET NAMEPAGE NUMBER REVISIONCONFIDENTIAL - THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT BLUE RAVEN SOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF BLUE RAVEN SOLAR LLC.SSSPEC SHEET0CONTRACTOR:BRS FIELD OPS385.498.6700PV INSTALLATIONPROFESSIONALScott Gurney# PV-011719-015866NABCEPCERTIFIED1403 N RESEARCH WAY, BUILDING JOREM, UT 84097800-377-4480WWW.BLUERAVENSOLAR.COM SHEET NAMEPAGE NUMBER REVISIONCONFIDENTIAL - THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT BLUE RAVEN SOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF BLUE RAVEN SOLAR LLC.SSSPEC SHEET0CONTRACTOR:BRS FIELD OPS385.498.6700PV INSTALLATIONPROFESSIONALScott Gurney# PV-011719-015866NABCEPCERTIFIED1403 N RESEARCH WAY, BUILDING JOREM, UT 84097800-377-4480WWW.BLUERAVENSOLAR.COM SHEET NAMEPAGE NUMBER REVISIONCONFIDENTIAL - THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT BLUE RAVEN SOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF BLUE RAVEN SOLAR LLC.SSSPEC SHEET0CONTRACTOR:BRS FIELD OPS385.498.6700PV INSTALLATIONPROFESSIONALScott Gurney# PV-011719-015866NABCEPCERTIFIED1403 N RESEARCH WAY, BUILDING JOREM, UT 84097800-377-4480WWW.BLUERAVENSOLAR.COMMonoMulti SolutionsIEC61215/IEC61730/IEC61701/IEC62716ISO 9001: Quality Management SystemISO 14001: Environmental Management SystemISO14064: Greenhouse Gases Emissions Veriÿcation OHSAS 18001: Occupation Health and Safety Management SystemTSM-DD06M.05(II)310-335WEU-28 WEEECOMPLIANTRECYCLABLEPACKAGINGISO 9001Quality Management Systemwww.tuv-sud.com/ms-cert××××××××××MONOCRYSTALLINE MODULEPOWER OUTPUT RANGEMAXIMUM EFFICIENCY0~+5WPOSITIVE POWER TOLERANCE310-335W19.7%Founded in 1997, Trina Solar is the world's leading total solution provider for solar energy. With local presence around the globe, Trina Solar is able toprovide exceptional service to each customer in each market and deliver our innovative, reliable products with the backing of Trina as a strong, bankable brand. Trina Solar now distributes its PV products to over 100 countries all over the world. We are committed to building strategic, mutually beneÿcial collaborations with installers, developers, distributors and other partners in driving smart energy together.Comprehensive Products and System CerticatesTHEMULTI-BUSBAR 120 HALF-CELL BOB MODULE 120-CellBlack PRODUCTS BACKSHEET POWER COLOR RANGE FRAME COLOR: Black Outstanding visual appearance, easy to install•Designed for superior rooftop aesthetics• Thinner wires give a eye cacthing all black lookTrina StandardGuaranteed Power83.1%90%100%97.5%Years510152025PERFORMANCE WARRANTY10 Year Product Warranty · 25 Year Power WarrantyFrom the 2nd year to the 25th year, the average annual power decline will be no more than 0.6%.• Safe and easy to transport, handle, and installHigh power output•Reduce BOS cost with high power bin and module efficiencyNew cell string layout and split J-box location reduces the energy losscaused by inter-row shading•High energy generation, low LCOE• Excellent 3rd party validated IAM and low light performance with cell • Low Pmax temp coefficient (-0.36%) increases energy production•Better anti-shading performance and lower operating temperature• High PID resistance through cell process and module material control• Resistant to salt, acid, sand, and ammonia• Over 30 in-house tests (UV, TC, HF etc)Certified to perform in highly challenging environmentsprocess and module material optimization• Certified to 5400 Pa positive load and 2400 Pa negative load• Lower resistance of half-cut cells and increased MBB (Multi Busbar)reflectance ensure higher powerCurrent (A)Voltage(V)P-V CURVES OF PV MODULE (335W)Voltage(V)Power (W)ELECTRICAL DATA (STC) TEMPERATURE RATINGSMAXIMUM RATINGSOperational TemperatureMaximum System Voltage1000V DC (IEC)1000V DC (UL)(Please refer to product warranty for details)WARRANTY10 year Product Workmanship Warranty25 year Power WarrantyPACKAGING CONFIGURATIONModules per box: 30 piecesModules per 40’ELECTRICAL DATA (NMOT)MECHANICAL DATAMonocrystalline 120 cells (6× 20)1698 × 1004 × 35 mm (66.85× 39.53 × 1.38 inches)18.7kg (41.2lb)3.2mm (0.13 inches), High Transmission, AR Coated Tempered Glass EVABlack 35 mm (1.38 inches) Anodized Aluminium AlloyIP 68 ratedPhotovoltaic Technology Cable 4.0mm2 (0.006 inches2) Portrait: N 140mm/P 285mm (5.51/11.22 inches) Landscape: N 1200 mm /P 1200 mm (47.24/47.24 inches)MC4 Solar CellsCell OrientationModule DimensionsWeightGlassBacksheetJ-BoxCablesConnectorFrameEncapsulant Material010 20 30 40 501.02.03.04.05.06.07.08.09.010.0600W/400W/200W/010 20 30 40 5050100150200250350300Max Series Fuse Rating 20A11.024631.67.7938.18.30600W/400W/200W/I-V CURVES OF PV MODULE (335W)1000W/DIMENSIONS OF PV MODULE(mm) container: 780 pieces32533.69.6740.410.3019.125031.77.8638.38.3833033.89.7640.610.4019.425431.97.9438.48.4633534.09.8540.710.5019.724231.47.7138.08.2232033.49.5840.310.2018.823831.27.6437.88.1531533.29.4940.110.1218.523531.07.5737.68.0831033.09.4039.910.0318.241°C (±3°C)- 0.36%/°C- 0.26%/°C0.04%/°C-40~+85°CCAUTION: READ SAFETY AND INSTALLATION INSTRUCTIONS BEFORE USING THE PRODUCT.© 2019 Trina Solar Limited. All rights reserved. Speciÿcations included in this datasheet are subject to change without notice. Version number: TSM_DD06M.05(II)_EN_2019_B www.trinasolar.comNMOT(Nominal Module OperatingTemperature)Temperature Coefficient of PMAXTemperature Coefficient of VOCTemperature Coefficient of ISCMaximum Power-PMAX (Wp)Maximum Power Voltage-VMPP (V)Maximum Power Current-IMPP (A)Open Circuit Voltage-VOC (V)Short Circuit Current-ISC (A)NMOT: Irradiance at 800W/m2, Ambient Temperature 20°C, Wind Speed 1m/s.STC: Irradiance 1000W/m2, Cell Temperature 25°C, Air Mass AM1.5.*Measuring tolerance: ±3%.(Do not connect Fuse in Combiner Box with two or more strings in parallel connection)A-A35 3511.5LaminateSilicon SealantFrame835 24.5LaminateB-BSilicon SealantFrame0 ~ +5Peak Power Watts-PMAX (Wp)*Power Output Tolerance-PMAX (W)Maximum Power Voltage-VMPP (V)Maximum Power Current-IMPP (A)Open Circuit Voltage-VOC (V)Short Circuit Current-ISC (A)Module Efficiency ȫm (%)MULTI-BUSBAR 120 HALF-CELL BOB MODULENameplate9591698 35AA6- 4.3Grounding Hole12-Drain Hole1004Microinverter or Optimizer Configuration1004String Inverter ConfigurationJunction Box4- 9×14Installing HoleJunction Box990Nameplate9591698 35AA6- 4.3Grounding Hole12-Drain Hole4- 9×14Installing Hole990180B B B B SHEET NAMEPAGE NUMBER REVISIONCONFIDENTIAL - THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT BLUE RAVEN SOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF BLUE RAVEN SOLAR LLC.SSSPEC SHEET0CONTRACTOR:BRS FIELD OPS385.498.6700PV INSTALLATIONPROFESSIONALScott Gurney# PV-011719-015866NABCEPCERTIFIED1403 N RESEARCH WAY, BUILDING JOREM, UT 84097800-377-4480WWW.BLUERAVENSOLAR.COM 304.80mm12.00in 266.70mm10.50in 183.97mm7.24in 41.37mm1.63in 198.37mm7.81in 77.09mm3.04in 24.81mm.98in 86.66mm3.41in ITEM NO.PART NUMBERDESCRIPTIONQTY.1JB-1 Body w/ E-Z LOK TECHNOLOGYPOLYCARBONATE WITH UV INHIBITORS12JB-1 Lid w/ GasketPOLYCARBONATE WITH UV INHIBITORS134#8 x 1-1/4” Phillips pan head screwAABB44332211EZ SOLARDO NOT SCALE DRAWINGJB-1SHEET 1 OF 3UNLESS OTHERWISE SPECIFIED:SCALE: 1:2WEIGHT: REVDWG. NO.BSIZETITLE:NAMEDATECOMMENTS:Q.A.MFG APPR.ENG APPR.CHECKEDDRAWNFINISHMATERIALINTERPRET GEOMETRICTOLERANCING PER:DIMENSIONS ARE IN INCHESTOLERANCES:FRACTIONALANGULAR: MACH BEND TWO PLACE DECIMAL THREE PLACE DECIMAL APPLICATIONUSED ONNEXT ASSYPROPRIETARY AND CONFIDENTIALTHE INFORMATION CONTAINED IN THISDRAWING IS THE SOLE PROPERTY OFEZ SOLAR. ANY REPRODUCTION IN PART OR AS A WHOLEWITHOUT THE WRITTEN PERMISSION OF<INSERT COMPANY NAME HERE> IS PROHIBITED.!"#$%& '(&)*+*),-*"./ 0&#-*+*),-*".1/ 2&*34- 567'8/4 15-20 lbs-in UL Standard 1741, NEMA 3R1.3 lbs EZ Solar SLC, UT USAPhone (385) 202-4150 www.ezsolarproducts.com10-32 x 1” Phillips pan head bolt SHEET NAMEPAGE NUMBER REVISIONCONFIDENTIAL - THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT BLUE RAVEN SOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF BLUE RAVEN SOLAR LLC.SSSPEC SHEET0CONTRACTOR:BRS FIELD OPS385.498.6700PV INSTALLATIONPROFESSIONALScott Gurney# PV-011719-015866NABCEPCERTIFIED1403 N RESEARCH WAY, BUILDING JOREM, UT 84097800-377-4480WWW.BLUERAVENSOLAR.COM 304.80mm12.00in 266.70mm10.50in 6.60mm0.26in 3.302mmR0.13in3 . 1 7 5mm 0 . 1 3 in 170.73mm6.72in 12.42mm0.49in 19.81mm0.78in 175.61mm6.91in 50.80mm2.00in 15.88mm0.625in AAIndent 55.89mm2.20in 57.94mm2.28in 57.94mm2.28in 9.53mm0.38in 5.55mm0.22in SECTION A-ASCALE 1 : 1EZ SOLARDO NOT SCALE DRAWINGJB-1SHEET 2 OF 3UNLESS OTHERWISE SPECIFIED:SCALE: 1:2WEIGHT: REVDWG. NO.BSIZETITLE:NAMEDATECOMMENTS:Q.A.MFG APPR.ENG APPR.CHECKEDDRAWNFINISHMATERIALINTERPRET GEOMETRICTOLERANCING PER:DIMENSIONS ARE IN INCHESTOLERANCES:FRACTIONALANGULAR: MACH BEND TWO PLACE DECIMAL THREE PLACE DECIMAL APPLICATIONUSED ONNEXT ASSYPROPRIETARY AND CONFIDENTIALTHE INFORMATION CONTAINED IN THISDRAWING IS THE SOLE PROPERTY OFEZ SOLAR. ANY REPRODUCTION IN PARTOR AS A WHOLE WITHOUT THE WRITTENPERMISSION OF EZ SOLAR IS PROHIBITED.AABB44332211 SHEET NAMEPAGE NUMBER REVISIONCONFIDENTIAL - THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT BLUE RAVEN SOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF BLUE RAVEN SOLAR LLC.SSSPEC SHEET0CONTRACTOR:BRS FIELD OPS385.498.6700PV INSTALLATIONPROFESSIONALScott Gurney# PV-011719-015866NABCEPCERTIFIED1403 N RESEARCH WAY, BUILDING JOREM, UT 84097800-377-4480WWW.BLUERAVENSOLAR.COM 183.97mm7.24in 198.37mm7.81in AA 22.23mm.88in 3.18mm.13in SECTION A-ASCALE 1 : 2LID OVERHANGOUTSIDEINSIDEAABB44332211EZ SOLARDO NOT SCALE DRAWINGJB-1SHEET 3 OF 3UNLESS OTHERWISE SPECIFIED:SCALE: 1:2WEIGHT: REVDWG. NO.BSIZETITLE:NAMEDATECOMMENTS:Q.A.MFG APPR.ENG APPR.CHECKEDDRAWNFINISHMATERIALINTERPRET GEOMETRICTOLERANCING PER:DIMENSIONS ARE IN INCHESTOLERANCES:FRACTIONALANGULAR: MACH BEND TWO PLACE DECIMAL THREE PLACE DECIMAL APPLICATIONUSED ONNEXT ASSYPROPRIETARY AND CONFIDENTIALTHE INFORMATION CONTAINED IN THISDRAWING IS THE SOLE PROPERTY OFEZ SOLAR. ANY REPRODUCTION IN PART OR AS A WHOLEWITHOUT THE WRITTEN PERMISSION OF<INSERT COMPANY NAME HERE> IS PROHIBITED. SHEET NAMEPAGE NUMBER REVISIONCONFIDENTIAL - THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT BLUE RAVEN SOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF BLUE RAVEN SOLAR LLC.SSSPEC SHEET0CONTRACTOR:BRS FIELD OPS385.498.6700PV INSTALLATIONPROFESSIONALScott Gurney# PV-011719-015866NABCEPCERTIFIED1403 N RESEARCH WAY, BUILDING JOREM, UT 84097800-377-4480WWW.BLUERAVENSOLAR.COM SHEET NAMEPAGE NUMBER REVISIONCONFIDENTIAL - THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT BLUE RAVEN SOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF BLUE RAVEN SOLAR LLC.SSSPEC SHEET0CONTRACTOR:BRS FIELD OPS385.498.6700PV INSTALLATIONPROFESSIONALScott Gurney# PV-011719-015866NABCEPCERTIFIED1403 N RESEARCH WAY, BUILDING JOREM, UT 84097800-377-4480WWW.BLUERAVENSOLAR.COM SHEET NAMEPAGE NUMBER REVISIONCONFIDENTIAL - THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT BLUE RAVEN SOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF BLUE RAVEN SOLAR LLC.SSSPEC SHEET0CONTRACTOR:BRS FIELD OPS385.498.6700PV INSTALLATIONPROFESSIONALScott Gurney# PV-011719-015866NABCEPCERTIFIED1403 N RESEARCH WAY, BUILDING JOREM, UT 84097800-377-4480WWW.BLUERAVENSOLAR.COMSFM SUNFRAMEMICRORAIL™INSTALLATION GUIDEPAGESYSTEM COMPONENTS CTrimrailTM FlashkitSub-Components: L-FootHex boltTri-drive nutChannel NutScocket Head Cap Screw3"Channel/Slider w/grommet3" Wide FlashingStructural Screw & SS EPDM WasherFunctions:•Attach TrimrailTM to roof attachment / flashing•Patented roof sealing technology at roof attachment point Features: •Slot provides vertical adjustments to level array•Slider provides north/south adjustment along theslope of the roof•Shed and Seal Technology TrimrailTM and Module ClipsSub-Components: 1. Trim Rail2. Module Clip3. T-Bolt4. Tri-Drive NutTrimrailTMFunctions: •Required front row structural support (with module clips)•Module mounting•Installation aid•Aesthetic trimFeatures: •Mounts directly to L-feet•Aligns and captures module leading edge•Supports discrete module thicknesses from 32, 33, 35, 38, and 40mmModule ClipsFunctions: •Required front row structural support (with trimrail)•Module mountingFeatures: •Mounts to TrimrailTM with T-bolt and tri-drive nut•Manually adjustable to fit module thicknesses 32, 33, 35,38, and 40mm.TrimrailTM SpliceSub-Components: 1.Structural Splice Extrusion2.Bonding ClipFunctions: •Front row structural support•Installation aid•Structurally connects 2 pieces of TrimrailTM•Electrically bonds 2 pieces of TrimrailTMFeatures: •Aligns and connects TrimrailTM pieces•Tool-less installation SHEET NAMEPAGE NUMBER REVISIONCONFIDENTIAL - THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT BLUE RAVEN SOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF BLUE RAVEN SOLAR LLC.SSSPEC SHEET0CONTRACTOR:BRS FIELD OPS385.498.6700PV INSTALLATIONPROFESSIONALScott Gurney# PV-011719-015866NABCEPCERTIFIED1403 N RESEARCH WAY, BUILDING JOREM, UT 84097800-377-4480WWW.BLUERAVENSOLAR.COMSFM SUNFRAMEMICRORAIL™INSTALLATION GUIDEPAGESYSTEM COMPONENTS DSFM Slider FlashkitSub-Components: 1.Slider w/grommet2.Structural Screw & SS EPDM washer3.3" Wide FlashingFunctions: • Patented Shed & Seal roof sealing technology at roof attach-ment point•For use with compatible 2" Microrail or 8" Attached SplicesFeatures: •Slider provides north/south adjustment along theslope of the roof•Shed and Seal TechnologyWire Bonding Clip w/ 8AWGFunctions: •Row to row bonding•Module to TrimrailTM bonding•Single Use OnlyFeatures: Tool-less installation MLPE Mounting AssemblySub-Components: 1.MLPE Mount Base2.5/16 Socket Head Cap Screw3.Bonding PinFunctions: •Securely mounts MLPE to module frames•MLPE to module bondingFeatures: •Mounts easily to typical module flange•UL2703 RecognizedMLPE = Module Level Power Electronics, e.g. microinverter or power optimizerModule-to-Module N-S BondingSub-Components: 1.Clamp2.Bonding Pins (2)3.5/16" Socket Head Cap Screw4.Clamp BaseFunctions/ Features: •Row to row bonding•Single Use Only•Fits module sizes 32-40mmTrim -to- Module Bonding Clampand Floating Trim ClampSub-Components: 1.Wedge2.Bonding Pin3.T-Bolt4.Nut5.Cast BaseFunctions/ Features: •Module to TrimrailTM bonding - single use only•Attaches TrimrailTM to module when fewer than2 rafter attachment points are available•Fits module sizes 32-40mm•Fits module sizes 32-40mm SHEET NAMEPAGE NUMBER REVISIONCONFIDENTIAL - THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT BLUE RAVEN SOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF BLUE RAVEN SOLAR LLC.SSSPEC SHEET0CONTRACTOR:BRS FIELD OPS385.498.6700PV INSTALLATIONPROFESSIONALScott Gurney# PV-011719-015866NABCEPCERTIFIED1403 N RESEARCH WAY, BUILDING JOREM, UT 84097800-377-4480WWW.BLUERAVENSOLAR.COMSFMSUNFRAMEMICRORAIL™INSTALLATION GUIDEPAGEFLASHING & SLIDERSGPILOT HOLES: Drill pilot holes for lag screws or structural screws (as necessary) at marked attachement pointsFLASHINGS:Place fl ashingsINSTALL SLIDERS AND TRIMRAIL ROOF ATTACHMENTS:• Insert fl ashings per manufacturer instructionsNOTE: Use Lag screw or structural fastener with a maximum diameter of 5/16" •Attach sliders to rafters•Verify proper row to row spacing for module size (Mod NS + 1")•Ensure that TrimrailTM roof attachments in each row have suffi cientengagement with slider dovetails for proper attachment.INSTALL SLIDERS AND ROOF ATTACHMENTS:Follow manufacturer instructionsfor fl ashing installation proceduresNOTE: If N-S module edge is within 1” of the shingle course above, you have the option to pivot / rotate slider at the attachment point to span the next course and cut shingles as required.UP-SLOPEDOWN-SLOPEMod NS + 1"Mod NS + 1"N/S MODULE EDGERotate SliderCut Shingles as RequiredLess Than 1"3"