HomeMy WebLinkAboutM100.0GENERAL NOTES 1. READ EN71RE DRAN7NGS SPECIFlCATIONS. 2. MECHANICAL CON7RACTOR IS RESPONSIBLE FOR BIDDING EN71RE SET OF CON7F2ACT DRAWINGS AND DOCUMENTS NOT JUST 7HE AIECHANICAL SHEETS. 3. ALL HVAC EQUIPMENT REQUIRING POWER SHALL BE VERIFlED N7hi ELECTRICAL CONTRACTOR PRIOR TO ORDERIN� EQUIPMENT. ALL SUBS71TUilONS OF HVAC EQUIPMENT REWIRING ELECTRICAL POWER SHALL BE FULL RESPONSIBILIN OF MECHANICAL CONTRACTOR. 4. DUCTNORK LOCATED BELOW 7'-6' IN MECHANICAL ROOMS SHALL BE EQUIPPED W/ PADDING MATERIAL ON ALL CORNERS, EDGES & OhiER SURFACES WHICH MAY BE HAZARDWS. 5. CONCRETE HOUSEKEEPING PADS SHALL BE LOCAIED 8Y 7HE MECHANICAL CON7RACTOR AND INSTALLED BY hIE GENERAL CON7RACTOR. hIE PADS SHALL EX7END A MINIAIUM OF 6" BEYIXJD EACH SIDE OF THE EQUIPMENT FOO7PRINT. 6. CONTRACTOR SHALL PROVIDE IEMPORARY HEAT AS REQUIRED AND SHALL NOT USE EWIPMENT TO HEAT OR COOL A SPACE hIAT WILL REMAIN IN 7HE BUILDING AFTER CLOSE WT OF CONSl(iUC110N. 7. ALL lESTS ON EQUIPAIENT SHALL BE COMPLEIED BEFORE ANY MECHANICAL EQUIPMENT OR PIPING INSULA710N IS APPLIED. 8. ALL DUCiWORK, PIPING AND TEMPERANRE CIXJTROL CIXJDUIT TO VIBRATING EQUIPMENT SHALL HAVE FLEXIBLE CONNECTORS. VENTILATION REQUIREMENTS SEE SHEET M2.1 FOR VENTILAlION REQUIREMENTS. MECHANICAL COMCHECK SEE SHEET M0.3 FOR MECHANICAL COMCHECK MECHANICAL SHEET INDEX/CODES ISSUE JURISDICTION: CARMEL, INDIANA o F MECHANICAL CODE: 2014 INDIANA MECHANICAL CODE (IMC 2012) � FUEL GAS CODE: 2014 INDIANA FUEL GAS CODE (IFGC 2012) Z 0 ENERGY CODE: 2010 INDIANA ENERGY CONSERVATION CODE (ASHRAE 90.1 2007) � 0 I O N \ \ SHEET N0. SHEET DESCRIPiION o M0.1 MECHANICAL COVER SHEET X M0.2 MECHANICAL SPECIFICAl10NS X M0.3 MECHANICAL SCHEDULES X M1.1 MECHANICAL FLOOR PLAN X M2.1 MECHANICAL DETAILS & VENTILATION X DESIGN PARAMETERS ELEVA710N: 901 FT ABOVE SEA LEVEL WINTER DESIGN: 2.0' F. SUMMER DESIGN IEMP DB/WB: 91.0' F/ 75.1' F DB DESIGN FOR AIR COOLED EQUIPMENT: 101' F HVAC DEMO/EXISTING CONDITIONS NOTES 1. ALL INFORMATON AND WORK SHOWN AS EXIS7ING WAS TAKEN FROM NOlES OF CURSORY FIELD VISITS BY hiE ENGINEER AND FROM PAST WORK CONS71iUCTION DOCUMENTS. CON7RACTOR, SHALL BE RESPONSIBLE FOR DETERMINING ALL DEMOLITION WORK NECESSARY BASED UPON ACNAL FlELD CONDIiIONS. ANY ADDI710NAL DEMOLITION WORK NEEDED TO FULLY COMPLElE NEW OR REMODELING/RENOVA710N WORK, BUT NOT OTHERWISE SHONT! OR DESCRIBED IN THE DEMOLI7IIXJ DRAN7NGS, SHALL BE CONSIDERED PART OF CON7F2ACT. 2. ALL DEMOLI710N WORK SHALL BE PERFORMED N7TH "DUE CARE AND DILIGENCE" SO AS TO PRE�ENT UNNECESSARY DESTRUCTION AND/OR DAMAGE TO SYS7EMS 7HAT SHALL REMAIN IN OPERATION AT THE CONCLUSION OF hilS WORK. DETERMINE EXACT LOCAlION OF ALL EXISIING EQUIPMENT, DEVICES, AND WIRING BEFORE COMMENCING WORK. 3. hiE CON7RACTOR SHALL DETERMINE EXACT LOCA710N OF ALL EXISTING DEVICES, EQUIPMENT, DUCiWORK, HANGERS, PLUMBING FlXNRES, LIGHIING FI%TURES, CONTROL WRING, ELEC7(iICAL WIRING, PLUMBING DOMES7IC WATER PIPING, STORM LINES, GAS PIPING, AND WAS7E/VENT BEFORE COMMENCING WORK. 7HE CON7F2ACTOR SHALL BE FULLY RESPONSIBLE FOR ANY AND ALL DAMAGES THAT MIGHT OCCUR BECAUSE OF 7HE CON7RACTOR�S FAILURE TO ACCURAlELY DISCOVER, LOCATE, AND PROTECT ANY AND ALL PORTION OF THE EXISTING MEP SYSTEM. 4. 7HE CON7FiACTOR SHALL PROVIDE ALL CUTfING AND PATCHING NECESSARY TO REPAIR ANY DAMAGE CAUSED BY CONS7RUCTION AC71VI71ES PERFORMED BY THE CONTRACTOR. THIS WORK INCLUDES AREAS OUTSIDE ANY LIMIT OF CONSTRUC110N LINES SHOWN ON THE DRAWINGS. 5. OWNER/LANDLORD TO HA�E CHOICE OF SALVAGE PLUAIBING FlXTURES/PIPING AND MECHANICAL E�UIPMENT WFIICH ARE SHONM TO BE REMOVED BY CON71iACTOR. IlEMS NOT SALVAGED BY OWNER SHALL BE REMOVED FROM SITE AND PROPERLY DISPOSED BY CON7RACTOR. 6. BEFORE REMOVAL OF ANY MECHANICAL EWIPAIENT, CON7RACTOR SHALL RECOVER USED REFRIGERANT IN A PROPERLY LABELED D.O.T. APPROVED REFlLLABLE CriINDER TO MEET E.P.A. STANDARDS. RECOVERED REFRIGERANT MUST BE CHEMICALLY ANALYZED AND REPROCESSED OR DISPOSED OF PER E.P.A. REQUIREMENTS, SECTION 608 OF 7HE CLEAN AIR ACT AND A.R.I. STANDARD 700. 7. ALL RE-USED DUCTNORK SHALL BE CLEANED AND PROTEC7ED DURING CONSTRUCiION FROM DEBRIS AND/OR DRYWALL DUST FROM PENE7F2APNG INTO MAIN DUCT. ONCE WORK IS FlNISHW (E) R7U SHALL RUN A PERIOD OF 48 HOURS AND CONTRACTOR SHALL PROVIDE ALL NEW FILTERS BEFORE AND AFTER. C� JOE C� C� N U � C O � 0 � � � � � � U � N^` W ! 2020-OS-22 C� C� C� � � REVISIONS k Da�e Descrip�lon � DAiE: PROJECiNO: DkA W N BY: ISSUED FOR: � 0 m � 5 M N O �P � o N O N � �� N V `� c� U � 31 MAR 2020 19082 3CE Consfvcfion � Mechanical CoverSheet � RELEA5E0 FOR CONSTRIICTI�N Su6jec��o compliance with allregula�ions of S�a�e antl Local Codes City of Carmel ��n„� i�•va,2,a! DATE: 07�� 4�20 iais aan n.e. w., oe��e�. co sozos p30335].1998 � 3consultlngenglnears-wm � � M0.1 C�