HomeMy WebLinkAboutP100.0PLUMBING SPECIFICATIONS AND NOTES
7HE CON7RACTOR, AND HIS SUBCONIRACTORS AND SUPPLIERS,
SHALL INCLUDE IN HIS BID ALL MIATERIALS, LABOR, AND
EpUIPMENT INVOLOED, IN ACCORDANCE W11H ALL LOCAL CUSTOMS,
CODES, RULES, REGULAlI0N5; AND SEWRE COMPLIANCE OF ALL
PARTS OF 1HE SPEqfICATIONS AND DRAWINGS REGARDLESS OF
SECTIONAL INCWSION IN 7HESE SPEqFICATI0N5. 1HE CONTRACTOR
SHALL BE RESPONSIBLE FOR 7HE COMPLETE AND SATISFACTORY
ACCOMPLISHMENT OF ALL WORK INCLUSIVE OF WfiAIEVER
MISCELLANEOUS MATERIAL AND/IX2 APPURTENANCES ARE REQUIRED
TO PERFECT THE INSTALLATION, AND DEAIONSTRATE THAT ALL
ELEC7RICAL SYSIEMS W1LL OPERAIE SATISFACTORILY UNDER
NORMAL OPERA7ING CONDITIONS.
DO NOT SCALE DRAWINGS. THE DRAWINGS ARE DIAGRAMMATIC AND
SHOW 1HE GENERAL LOCATION AN� ARRANGEMENT OF EpUIPMENT,
PIPING AND RELATED ITEMS. THEY SHALL BE FOLLOWED AS
CLOSELY AS ELEMENTS OF THE CONS7RUC710N W1LL PERMIT. THE
CONIRACTOR SHALL PRONDE/INSTALL ALL PLUMBING SYS7EMS,
AND ASSOCIATED E�UIPMENT, COMPLEIE AND INCLUDE ALL
NECESSARY OFFSETS, FlT7INGS, AND OTHER COMPONENTS REQUIRED
DUE TO INIERFERENCES, SPACE CONSIRAINTS, CODE
REpUIREMENTS, ETC. AS REQUIRED TO PRONDE A
COMPLEIE/FUNCTIONAL SYS7EM.
WORK SHALL BE COORDINATED W1TH THE WORK OF OTHER TRADES.
CON7RACTOR SHALL GUARANIEE THAT ALL LABIX2, MAIERIALS, AND
EpUIPMENT ARE FREE FROM DEFECTS AND AGREES TO REPLACE OR
REPAIR ANY PART OF 7HIS INSTALI.A710N WHICH BECOMES
DEFECII�E WIIHIN A PERIOD OF ONE YEAR FROM THE DATE OF
SUBSTANTIAL COMPLETION FOLLOWING FlNAL ACCEPTANCE.
ACCEPTANCE DATE OF SUBSTANTIAL COMPLETION SHALL BE AS
ENGMEER. DETERMINED BY 1HE ARCHITECT AND/OR ENGINEER.
• SIZES, INVERTS AND POINTS OF CONNEC110N OF EXISTING
PWMBING PIPING AND U1ILITIES SHALL VERIFIED IN 7HE FIELD
PRIOR TO BEGINNING WORK.
PROVIDE COA1PLElE MAINIENANCE AND OPERA7ING INSIRUC110NAL
MANUALS COVERING ALL PLUMBING EQUIPMENT AND INDIVIDUAL
E�UIPMENT SPEqFICATION SECTIONS.
• ALL SHOP DRAWINGS AND E�UIPMENT SUBMIITTALS SHALL BE
SUBMITTED AS A COMPLETE PACKAGE, NOT PIECE MAIL. ALL
SUBMITTALS SUBMITTED INDINDUALLY SHALL BE RENRNED
UNCHECKED. EXCEP710NS TO hIIS ONLY SHALL INCLUDE LONG LEAD
IIEMS.
INSTALL EqUIPMENT IN STRICT ACCORDANCE INTH ALL DIRECTIONS
AND RECOMMENDA➢ONS fURNISHED BY THE MIANUFACIDRER.
WHERE SUCH DIRECTIONS ARE IN CONFLICT W1TH 1HE DRAHINGS
AND SPECIFlCATIONS, REPORT SUCH CONFLICTS TO 7HE ARCHIIECT
AND/OR ENGINEER FOR RESOLUTION.
PRONDE AND INSTALL SCHEDULE 40 BLACK STEEL PIPE SLEEVES,
WT TO LENG7H, NHERE�ER PIPES PASS THROUGH ABOVE GRADE
WALLS AND ROORS. PROVI�E AND INSTALL GALVANIZED STEEL
PIPE SLEEVES, CUT TO LENGTH, WHEREVER PIPES PASS THROUGH
BELOW GRADE FOUNDATION WALLS AND SLAB ON GRADE FLOORS.
SLEEVES SHALL lER1�INATE FLUSH W1TH WALLS IN FINISHED AREAS.
ALL SLEE�ES 1HRWGH THE FLOOR ARE TO EXTEND TWO (2)
INCHES ABOVE FlNISH ROOR. PRONDE ESCUTCHEONS AT EACH
PENE1RAlI0N 7HROUGH WALLS, fL00RS, AND CEILINGS IN PRONDE
ADEWATE CLEARANCE TO SEAL THE SPACE AROUND PIPES AND
SLEEVES hiROUGH WALLS, ROORS AND CEILINGS. PATCH SLEEVES
TO MIATCH BUILDING MAIERIALI EXPOSED AREAS. ALLOW FOR
PROPER PIPE MOVEMENT AND SEALING.
� PENEIRATIONS OF FlRE RAIED WALLS OR FLOORS BY PIPE SHALL
BE SEALED BY A FIRESTOPPING SYSIEM UL LISIED FIX2 THE
APPLICATION IN ACCORDANCE N1TH THE WALL RATING.
PENE1RAlI0N SEAL MATERIALS SHALL BE INSTALLED IN
ACCORDANCE W1TH PRINTED INSTRUCTIONS OF THE UL FlRE
RESISTANCE �IRECTORY AND MANUFACNRERS INSTRUCTIONS.
FIRESTOPPING SYSTEM SHALL BE EQUAL TO 3A1 FIRE BARRIER.
FIRESTOPPING MATERIAL SHALL BE CAULK OR PUTTY TYPE.
� PRONDE ALL EXCAVA710N, TRENCHIN6, IUNNELIN6 AND
BACKFILLING REQUIRED FOR THE PLUI�BING WORK IN ACCORDANCE
H1TH ADOPTED PLUMBING CODES.
� MAKE CONNECTIONS TO EWIPAIENT, FlXTURES AND OTHER ITEA15
INCLUDED IN THE WORK IN ACCORDANCE WI7H THE APPROVED
SHOP DRAWINGS AND ROUGH-IN MEASUREMENTS FURNISHED BY
THE IAANUFACNRES OF 7HE PARTICULAR EQUIPMENT FURNISHED.
� TEST DRAINAGE PIPING SYS7EMS IN ACCORDANCE W1TH THEIR
RESPECIIVE AND APPLICABLE GOVERNING CODES. IEST DRAINAGE
AND WASTE PIPING HIDRAULICALLY BY FlWNG THE SYSTEM TO ITS
HIGHEST POINT OR AT A STATIC HEAD OF 10 FEET, WHICHEVER IS
HIGHER.
• PRESSURE IEST PLUMBING PIPING (DOMESTIC COLD WAIER,
DOMESTIC HOT WATER, ETC.) IN ACCORDANCE W11H GOVERNING AND
APPLICABLE CODES. AT MINIMUM, IEST N17H WAIER AT 225 PSIG -
PERMISSIBLE PRESSURE DROP SHALL BE 0 PSIG OVER 2 HOUR
PERIOD.
DOMESIIC WATER PIPING SHALL BE INSULATED IN ACCORDANCE
W1TH GOVERNING AND APPLICABLE CODES. INSULA710N SHALL HAVE
A VAPOR BARRIER N1TH SELF-SEALING ADHESIVE JOINTS.
INSULAIE� PIPING EXPOSED TO VIEW SHALL BE CO�ERED AND
FINISHED Y�TH A 30 MIL, 1' 7HICK PVC JACKET. FlTIINGS, VALVES
AND ACCESSORIES SHALL ALSO BE JACKETED.
PIPING SHALL BE IDENIIFlED N11H PLAS7IC PIPE MARKERS IN CLEAR •
VIEW AND ALIGNED W1TH AXIS OF PIPING. SERVICE AND ROW
DIRECTION SHALL BE INDICATED. DISTANCE BETWEEN
IDENIIFICA710N LOCATIONS SHALL NOT EXCEED 20 FEET.
IDENIIFICA710N SHALL BE LOCAIED AT EACH VALVE, RUNOUT AND
ON BO7H SIDES OF AN OBS7RUC710N.
� PRONDE EX7EN�E� S1EMS ON VALVE TO KEEP HANDLES CLEAR OF
INSULATION.
PIPE HANGER SPACING:
METAL PIPING:
PIPE SIZE: 1/2 INCHES TO 1-1/4 INCHES:
MIAKIMUM HANGER SPACING: 6.5 FT.
HANGER ROD DIAMETER: 3/8 INCHES.
PIPE SIZE: 1-1/2 INCHES TO 2 INCHES:
MAXIMUM HANGER SPACING: 10 FT.
HANGER ROD DIAMETER: J/8 INCH.
PIPE SIZE: 2-1/2 INCHES TO 3 INCHES:
MIAXIMUM HANGER SPACING: 10 FT.
HANGER ROD DIAMETER: 1/2 INCH.
PIPE $IZE: 4 INCHES TO 6 INCHES:
MIARIMUM HANGER SPACING: 10 FT.
HANGER ROD DIAMETER: 5/8 INCH.
PLAS7IC PIPING:
ALL SIZES:
MAKIMUM HANGER SPACING: 4 FT.
HANGER ROD DIAMETER: 3/8 INCH.
• VENTS IERMINATED ABOVE ROOF SHALL BE 10' MINIMUM FROM
OUTSIDE AIR INTAKES AND/OR OPERABLE NINDOWS.
• FIXIDRE LOCATIONS AND MOUNTING HEIGHTS SHALL BE ACCORDING
TO THE ARCMTECNRAL �RAWINGS.
INSTALL WATER HAMAIER ARRESTORS COMPLETE W11H ACCESSIBLE
ISOLAlION VALVE ON HOT AND COLD WAIER SUPPLY PIPING TO
LAVATORIES, SINKS, WASHING MACHINE OUTLETS, WATER CLOSETS,
URINALS, DISHWASHERS, BA1H1U6$/$HOWERS, AND OTHER
APPLICABLE FIXIDRE LOCATIONS W11H WICK CLOSING VALVES.
INSTALL ASSE 1070 US7ED "POINT OF USE" THERMOSTA7IC MIXING
VALVES AT ALL ACCESSIBLE FlXNRES (LAVATORIES, SINKS, ETC.).
PRONDE LAV-SHIELDS UNDER LAVATORIES TO CONCEAL MIRING
VALVES.
COORDINATE INSTALLATIINJ OF FLOOR DRAINS AND FLOOR SINKS
N11H 7HE LOCAIE FLOOR DRAINS AND ROOR SINKS PER
ARCHITECTURAL DRAWINGS. CAST ROOR DRAINS AND ROOR
SINKS INTO THE WORK OF PLACING CONCRETE TO ASSURE PROPER
DRAIN ELEVAl10N AND ROOR SLOPE. ROOR DRAINS IN ABO�E
GROUND SLABS SHALL BE FLASHE� WITFi CONCREIE AT 7HE 71ME
THE FLOORS ARE PLACED AND MAKE WAlER11GHT. SEPARATE
FINISH VNTH SQUARE LEAD SHEET PANS. FLOOR �RAINS IN SLABS
ON GRADE PRONDED W1TH MEMBRANE OR METAL PAN
WATERPROOFING DO NOT REqUIRE LEA� FLASHING, BUT SHALL
HAVE PNO ADDITIONAL LAYERS OF THE WAIERPR00fING AT THE
ROOR DRAINS. fL00R DRAIN TRAP SIZE SHALL MATCH THE
OUTLET SIZE OF THE DRAIN AND 1HE SIZE SHOWN FLASHING SHALL
NOT OBS7RUCT 1HE l4EEPHOLES. ON THE PLANS. FLOOR DRAIN
1RAPS SUBJECT TO LOSS BY EVAPORA710N (I.E. STORAGE ROOMS,
MECHANICAL ROOMS, BATHROOMS, ETC.) SHALL HAOE A DEEP SEAL
1RAP CONSISTING OF AT LEAST A 4 INCH SEAL, A 1RAP PRIMER
CONNECTION, AND BE PROTECTE� BY A 7RAP PRIMER VALOE. 7RAP
PRIMIER VALVES SHALL BE PROVIDE 7RAP PRIMER TAP OFF TOP OF
DOMESTIC COLD WATER MAIN PIPE FEEDING NEARBY PLUMBING
FlXTURE. INSTALLED IN CONCEALED BUT ACCESSIBLE LOCATIONS
FOR MAINTENANCE.
• LINE WHICH CHANGES DIRECTION CLEANOUTS SHALL BE INSTALLED
IN ACCESSIBLE LOCAlI0N5 AND PROVIDED IN ANY HORIZONTAL
DRAINAGE CLEANOUTS IN HORIZONTAL DRAINAGE MORE THAN 45
DEGREES, AT THE END$ OF MAIN AND BRANCH RUNS, BASE OF
STAq(S, AND AT ALL TRAPS LINES LOCAIED INSIDE THE BUILDING
SHALL BE PROVIDED AT MAXIMUM SPACING OF 50 FEET FOR
DRAINS 4 INCHES AND SMIALLER. ALL HORIZONTAL DRAINAGE LINES
INSIDE THE BUILDING LARGER THAN 4 INCHES SHALL HAVE
CLEANWTS SPACED AT A MAXIMUM OF 80 FEET.
PLUMBING MATERIAL SCHEDULE
WAS7E PIPING (ABOVE GRADE�: ALL SIZES SHALL BE SCHEDULE 40 PVC PIPE AND FITTINGS SOLVENT NlELD JOINTS.
WASTE PIPING (BELOW GRADE�: ALL SIZES SHALL BE SCHEDULE 40 PVC PIPE AND FITTINGS SOLVENT WELD JOINTS.
VENT PIPING (ABOVE GRADE�: ALL SIZES SHALL BE SCHEDULE 40 PVC PIPE AND FITTINGS SOLVENT WELD JOINTS.
DOMESTIC WATER (ABOVE GRADE�: SIZES 1/2" TO 2" SHALL BE TYPE L COPPER W1TH WROUGHT COPPER FITTINGS AND
LEAD—FREE SOLDE JOINTS. ALL COPPER PIPING INSTALLED BELOW GRADE WITHIN THE BUILDING FOOTPRINT SHALL BE
ROUTED IN PVC CONDUIT FOR PROTECTION.
CONDENSATE DRAINS (ABOVE GRADE�: ALL SIZES SHALL BE TYPE M COPPER WI1H WROUGHT COPPER FITTINGS AND
LEAD—FREE SOL�ER J INTS.
DENTAL EQUIPMENT DRANl1NG SPECIFICATIONS SHALL TAKE PRECEDENCE.
VACUUM PIPING: ALL SIZES OF PIPE AND FITTINGS SHALL BE PVC SCHEDULE 40 DWV. CONFORM TO ASTM 84-68, NA1H
FLAME SPREAD OF 25 OR LESS. VACUUM PIPING SHALL BE SLOPED AT 1/4" PER 10� FROM FURTHEST OUTLET TO
EQUIPMENT ROOM. WHERE IN CONFLICT, DENTAL EQUIPMENT DRAWING SPECIFICATIONS SHALL TAKE PRECEDENCE.
: CAST IRON W1TH A CAP AND MESH
45 DEGREE BENDS. WHERE IN
�1�P1:31� i �.. ►17�.ILK�7�7�
JURISDIC110N: CARMEL, INDIANA
PLUMBING CODE: 2012 INDIANA PLUMBING CODE
FUEL GAS CODE: 2014 INDIANA FUEL GAS CODE
ENERGY CODE: 2010 INDIANA ENERGY CONSERVAlION CODE
SHEET N0. SHEET DESCRIPTION
P0.1 PLUMBING COVER SHEET
P0.2 PLUMBING SCHEDULES
P1.1 PLUMBING FLOOR PLAN
P1.2 COMPRESSED AIR AND VACUUM PLAN
P2.1 PLUMBING DETAILS
ISSUE
z
0
F
U
�
�
�
z
0
U
�
0
�
i
C�
C�
PIPING ABBR DESCRIPlION FIX/E�UIP ABBR DESCRIP710N
— — E%ISTING PIPING `"�� RD ROOF DRAINS (ROOft ABOVE)
��,�p DEMO PIPING TO BE REMOVED
W WASTE (ABOVE GRADE) OO OO RD ROOF DRAINS (SAME FLOOR)
--- W WAS7E (BELOW GRADE) � DSN DOWNSPOUT NOZZLE
"'_""_" V VENT
SD/OSD STORM DRAIN (ABOVE GRADE) � PUMP
— SD/OSD STORM DRAIN (BELOW GRADE) + HB HOSE BIBB
—��y— GW GREASE WASTE (ABOVE GRADE)
_��y__ ��y GREASE WASTE (BELOW GRADE) ABBRE�lAl10N5
FIRE LINE PIPING R REMOVE OR RELOCATE
—F— CW COLD WATER PIPING E EXISTING
---- HW HOT WATER PIPING (N) NEW
----- HWR HOT WATER RECIRC. PIPING (REF) REFERENCE
DFU DRAINAGE FIXTURE UNIT
—T— TW TEMPEftED WATER (IEMP. L151ED) �� WA�R SUPPLY FIXNRE UNIT
—G— G GAS PIPING
—MC— MG MEDIUM PRESSURE GAS PIPING AfF ABOVE FINISHED FLOOR
—GV— GV GAS PRESSURE REGULATOR VENT AFG ABOVE FINISHED GRADE
—D— D DRAIN PIPING BFF BELOW FINISHED FLOOR
FITTINGS ABBR DESCRIPl10N BFG BELOW FINISHEO GRADE
B7UH BRI7ISH THERMAL UNIT PER HOUR
� I� U UNION CFH CUBIC FEET PER HOUR
CO CLEANOUT
� IHERMOMETER W/IHERMOWELL F DEGREE FAHRENHEIT
FPM FEET PER MINUIE
� AV AIR VENT � FLOOR SINK
FD FLOOR DRAIN
FT WC FEET WATER COWMN
��� FC Fl.IXIBIE PIPE CONNECTOR IN WC INCHES WATER COWMN
PRES9JRE GAU(i W/ GAUGE COq( IRR IRRIGATION
PG GAL GALLON
O GPH GALLONS PER HWR
VIR VENT 7HRWGH ROOF GPM GALLONS PER MINUTE
KW KILOWATTS
o— ELBOW UP MAX MAXIMUM
MIN MINIMUAI
C ELBOW DONTI MBH 7HOUSAND BIUH
� lEE UP MCA MINIMUAI CIRCUIT AMPS
NOCP MAXIMUTA OVER CURRENT PROTECTON
lEE DOVM NTS NOT TO SCALE
OSD OVQ2FLOW STORM DRAIN
v PIPE CAP OR PLUG �RD OVERROW ROOF DRAIN
� PRE55 PRESSURE
� FCO ROOR CLEANOUT P51 POUNDS PER SWARE INCH
PW PUMPED WASTE
�I y/�p WALL CLEANOUT SPECS SPEQFICATIONS
SP STAl1C PRESUSURE
� PIPE REDUCER SD STORM DRAIN
TYP TYPICAL
VAL�'ES ABBR DESCRIPl10N W/ W1TM
w o vnn{our
�� SOV SHUT—OFF VALVE SYMBOLS ABBR DESCRIP710N
� �� CHEqC VALYE 1N7H INDICA710N Oi B
ROW DIREC710N F-1 DESIGNATION
� 1 —
PRV PRESSURE REDUqNG VALbE
� � SHEET KEY NOlES
SV SOLENOID VALVE
POINT OF CONN.
�qRWIT SETIEH OR BALANqNG VAL4£ � P� EX�STING EW TO
� CS,BV
� P� DSICONNECTION
� TpR lEA1PERANRE/ PRESSURE REIIEF
VALYE
�y S� S7RAINER W/ BLOW—OFF 8 CAPPED
rr HOSE— END fANNECTON
J'
� GV GAS VALVE/COCK
�GPR GAS PRE591RE REWLATqt
zr
C�
JOE
N
U
�
C
0
�
0
�
i
�
�
�
U
�
N^`
>W
>
C�
C�
C�
2020-03-31
+ +
REVISIONS
k Da�e Descrip�lon
�
DAiE:
PROJECiNO:
DkA W N BY:
ISSUED FOR:
�
0
N
��
N O
�P
m �
N O
m o
mc
N
V �
_ �
c� U
�
31 MAR 2020
19082
3CE
Consfvcfion
�
Plumbing
CoverSheet
�
RELEA5E0 FOR CONSTRIICTI�N
Su6jec� �o compliance with all regula�ions
of S�a�e antl Local Codes
City of Carmel
��n„� i�•va,2,a!
DATE: 07�� 4�20
P0.1
iais aan n.e. w., oe��e�. co sozos
p30335].1998 �
3consultlngenglnears-wm �
�
C�