Loading...
HomeMy WebLinkAbout42240029 - WWC 29 - Truss DetailsDE DANSCO ENGINEERING, LLC P.O. Box 3400 Apollo Beach, FL 33572 Telephone (813) 645-0166 Facsimile (813) 645-9698 The truss drawing(s) attached have been prepared by Dansco Engineering, LLC under my direct supervision and control based on the parameters provided by Stark Truss Inc. Job: 2004899-12T 6 9 truss design(s) 73384-W2 06 /11/2020 Samuel A. Greenberg, P.E. Indiana Reg. #19700485 Indiana Residential Building Code 2020 based on IRC 2018 with Indiana specific amendments. 675 IAC 14-4.4-81 Section R802.10.1; truss design drawings, R802.10.1; truss design drawings shall be provided to the building official as required by the General Administrative Rules (675 IAC 12) for Class 1 structures or by local ordinance for Class 2 structures. Note: Gable end frames with stud lengths exceeding 4’ require permanent bracing. On structural gables, where studs may be made from two or more boards as they cross diagonals, the 4’ length is the distance from the top chord to bottom chord. The seal on these drawings indicate acceptance of professional engineering responsibility solely for the truss components shown. The suitability and use of this component for any particular building is the responsibility of the building designer, per ANSI/TPI 1-2014 Chapter 2. Warning !—Verify design parameters and read notes before use. These designs are based only upon parameters shown, and are for individual building components to be installed and loaded vertically. Applicability of design parameters and proper incorporation of component is responsibility of building designer – not truss designer or truss engineer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to ensure stability during construction is the responsibility of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPI 1 National Design Standard for Metal Plate Connected Wood Truss Construction and BCSI 1-03 Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses from Truss Plate Institute, 583 D’Onofrio Drive, Madison, WI 53719 07/07/20 William Hohlt DE Job # 73384-W2 1 Dansco Engineering, LLC Date: 06/11/2020 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. 1.5x4 1220 19 1 11 102 3 9 84 5 6 7 T2 T1 T3 T2 T1 W1 W12 B1 B3B2 W3 W4 W5 W6 W7 W8 W7 W2 W11 W9 W10 ST5 ST4 ST2 ST3 ST1 Scale = 1:59.2 Plate Offsets (X, Y): [6:0-3-12,0-1-12], [7:0-2-15,0-1-14], [10:0-3-0,0-1-12] Loading (psf) Spacing 2-0-0 CSI DEFL in (loc) l/defl L/d PLATES GRIP TCLL (roof) 20.0 Plate Grip DOL 1.15 TC 0.79 Vert(LL) -0.03 12-13 >999 360 MT20 197/144 Snow (Pf/Pg) 20.4/20.0 Lumber DOL 1.15 BC 0.31 Vert(CT) -0.07 12-13 >999 240 TCDL 10.0 Rep Stress Incr NO WB 0.53 Horz(CT) 0.00 12 n/a n/a BCLL 0.0 Code IRC2018/TPI2014 Matrix-MSH BCDL 10.0 Weight: 225 lb FT = 20% LUMBER TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 *Except* B1:2x8 SP 2400F 2.0E WEBS 2x4 SPF Stud *Except* W5,W6,W7,W8,W9:2x4 SPF No.2, W1:2x6 SPF No.2 OTHERS 2x4 SPF Stud *Except* ST5:2x4 SPF No.2 BRACING TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (10-0-0 max.): 6-7. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. WEBS 1 Row at midpt 5-16, 6-16, 6-15, 7-15, 9-15 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS All bearings 21-4-0. except 20=0-4-0 (lb) - Max Horiz 20=330 (LC 11) Max Uplift All uplift 100 (lb) or less at joint(s) 12, 13 except 15=-158 (LC 13), 16=-124 (LC 12), 17=-539 (LC 37), 18=-760 (LC 12), 20=-258 (LC 8) Max Grav All reactions 250 (lb) or less at joint(s) 17 except 12=332 (LC 53), 13=507 (LC 37), 15=749 (LC 37), 16=436 (LC 37), 18=2354 (LC 37), 20=787 (LC 37) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 7-32=-12/271, 2-20=-319/226, 10-12=-276/113 BOT CHORD 20-35=-333/549, 19-35=-333/549, 19-36=-335/552, 36-37=-335/552, 18-37=-335/552, 16-17=-206/254, 15-16=-182/271 WEBS 3-19=-276/688, 3-18=-741/410, 5-18=-308/92, 7-15=-413/88, 3-20=-511/203, 9-15=-274/238, 9-13=-362/128 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=5.0psf; BCDL=5.0psf; h=30ft; Cat. II; Exp C; Enclosed; MWFRS (envelope) exterior zone; cantilever left and right exposed ; end vertical left and right exposed; porch left exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pg=20.0 psf; Pf=20.4 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10, Lu=50-0-0; Min. flat roof snow load governs. Rain surcharge applied to all exposed surfaces with slopes less than 0.500/12 in accordance with IBC 1608.3.4. 5) Unbalanced snow loads have been considered for this design. 6) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 15.4 psf on overhangs non-concurrent with other live loads. 7) Provide adequate drainage to prevent water ponding. 8) All plates are 1.5x4 MT20 unless otherwise indicated. 9) Gable studs spaced at 2-0-0 oc. 10) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 11) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 12, 13 except (jt=lb) 16=124, 18=759, 20=257, 15=158, 17=539. 12) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 13) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. Job Truss Truss Type Qty Ply DWH - Woodside at West Clay Lot 29 G01 1 12004899-12T Piggyback Base Girder Job Reference (optional) Run: 8.4 S 0 Mar 10 2020 Print: 8.400 S Apr 7 2020 M iTek Industries, Inc. Wed Jun 10 15:41:56 Page: 1 ID:xdpSk8AN_XPasF5M kPuv8dzW nZy-2s8wOqQI3Cup4LFaKRvSa2N_cDM9mWOzKTB4sXz7fHv Continued on page 2 07/07/20 William Hohlt DE Job # 73384-W2 1 Dansco Engineering, LLC Date: 06/11/2020 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. 14) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 130 lb down and 102 lb up at 3-1-0 on top chord, and 251 lb down and 172 lb up at 3-1-0, and 241 lb down and 115 lb up at 5-2-2, and 1173 lb down and 314 lb up at 7-2-2 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. LOAD CASE(S) Standard 1) Dead + Snow (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (lb/ft) Vert: 1-2=-51, 2-6=-51, 6-7=-61, 7-10=-51, 10-11=-51, 12-20=-20 Concentrated Loads (lb) Vert: 29=-75, 35=-251, 36=-241, 37=-1139 Job Truss Truss Type Qty Ply DWH - Woodside at West Clay Lot 29 G01 1 12004899-12T Piggyback Base Girder Job Reference (optional) Run: 8.4 S 0 Mar 10 2020 Print: 8.400 S Apr 7 2020 MiTek Industries, Inc. Wed Jun 10 15:41:56 Page: 2 ID:xdpSk8AN_XPasF5MkPuv8dzWnZy-2s8wOqQI3Cup4LFaKRvSa2N_cDM9mWOzKTB4sXz7fHv 07/07/20 William Hohlt DE Job # 73384-W2 1 Dansco Engineering, LLC Date: 06/11/2020 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. 3x4 =8x8 3x8 =4x6 3x4 7 6 5 1 2 3 4 W1 T1 W5 B1 W2 W3 W4 Scale = 1:30.5 Plate Offsets (X, Y): [6:0-3-8,0-4-8] Loading (psf) Spacing 2-0-0 CSI DEFL in (loc) l/defl L/d PLATES GRIP TCLL (roof) 20.0 Plate Grip DOL 1.15 TC 0.12 Vert(LL) -0.01 5-6 >999 360 MT20 197/144 Snow (Pf/Pg) 15.4/20.0 Lumber DOL 1.15 BC 0.61 Vert(CT) -0.02 5-6 >999 240 TCDL 10.0 Rep Stress Incr NO WB 0.42 Horz(CT) 0.00 5 n/a n/a BCLL 0.0 Code IRC2018/TPI2014 Matrix-MP BCDL 10.0 Weight: 31 lb FT = 20% LUMBER TOP CHORD 2x4 SPF No.2 BOT CHORD 2x6 SPF No.2 WEBS 2x4 SPF Stud *Except* W1:2x6 SPF No.2 BRACING TOP CHORD Structural wood sheathing directly applied or 5-8-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS (lb/size) 5=1083/ Mechanical, (min. 0-1-8), 7=856/0-4-0, (min. 0-1-8) Max Horiz 7=121 (LC 12) Max Uplift 5=-304 (LC 12), 7=-181 (LC 12) Max Grav 5=1193 (LC 2), 7=950 (LC 2) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-7=-870/178, 2-8=-1031/176, 3-8=-993/184 BOT CHORD 6-10=-235/888, 5-10=-235/888 WEBS 2-6=-133/930, 3-6=-208/979, 3-5=-1129/299 NOTES 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=5.0psf; BCDL=5.0psf; h=30ft; Cat. II; Exp C; Enclosed; MWFRS (envelope) exterior zone; cantilever left exposed ; end vertical left exposed; porch left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pg=20.0 psf; Pf=15.4 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 3) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 15.4 psf on overhangs non-concurrent with other live loads. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) Refer to girder(s) for truss to truss connections. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 181 lb uplift at joint 7 and 304 lb uplift at joint 5. 8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 826 lb down and 169 lb up at 2-4-12, and 826 lb down and 169 lb up at 4-4-12 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. LOAD CASE(S) Standard 1) Dead + Snow (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (lb/ft) Vert: 1-2=-51, 2-4=-51, 5-7=-20 Concentrated Loads (lb) Vert: 9=-754, 10=-754 Job Truss Truss Type Qty Ply DWH - Woodside at West Clay Lot 29 G02 1 12004899-12T Jack-Closed Girder Job Reference (optional) Run: 8.4 S 0 Mar 10 2020 Print: 8.400 S Apr 7 2020 M iTek Industries, Inc. Wed Jun 10 15:41:57 Page: 1 ID:twqVtaMzXF5xy62gsYiQTizWnb_-W2iIbARwqV0giVpnu9Rh7GwKqcdiV?M 6Y7wePzz7fHu 07/07/20 William Hohlt DE Job # 73384-W2 1 Dansco Engineering, LLC Date: 06/11/2020 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. 8x10 19 18 17 1615 14 13 12 11 10 9 1 82 7 63 4 5 T1 T2 T3 T4 W1 W14 B1 B2 W3 W4 W5 W6 W7 W8 W7 W9 W10 W11 W12 W2 W13 Scale = 1:58.8 Plate Offsets (X, Y):[4:0-10-0,0-2-0], [5:0-9-12,0-1-12], [9:0-4-4,Edge], [11:0-5-0,0-2-0], [12:0-3-8,0-4-0], [13:0-2-12,0-4-4], [14:0-4-0,0-4-4], [16:0-3-8,0-4-8], [17:0-3-0,0-4-4], [18:0-3-8,0-4-0], [19:0-5-0,0-0-8] Loading (psf) Spacing 2-0-0 CSI DEFL in (loc) l/defl L/d PLATES GRIP TCLL (roof) 20.0 Plate Grip DOL 1.15 TC 0.69 Vert(LL) -0.15 16-17 >999 360 MT20 197/144 Snow (Pf/Pg) 20.4/20.0 Lumber DOL 1.15 BC 0.46 Vert(CT) -0.24 16-17 >999 240 MT18HS 197/144 TCDL 10.0 Rep Stress Incr NO WB 0.91 Horz(CT) 0.05 11 n/a n/a BCLL 0.0 Code IRC2018/TPI2014 Matrix-MSH BCDL 10.0 Weight: 428 lb FT = 20% LUMBER TOP CHORD 2x4 SPF No.2 BOT CHORD 2x6 SP 2400F 2.0E WEBS 2x4 SPF No.2 *Except* W3,W4,W11,W12:2x4 SPF Stud, W1,W14:2x6 SPF No.2 BRACING TOP CHORD Structural wood sheathing directly applied or 3-5-4 oc purlins, except end verticals, and 2-0-0 oc purlins (4-11-1 max.): 4-5. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS (lb/size) 11=7692/0-6-0, (min. 0-3-5), 19=8693/0-6-0, (min. 0-3-12) Max Horiz 19=-330 (LC 8) Max Uplift 11=-2146 (LC 13), 19=-2050 (LC 12) Max Grav 11=8048 (LC 37), 19=9081 (LC 37) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-20=-8036/1810, 2-20=-7966/1822, 2-21=-8691/2025, 3-21=-8543/2037, 3-22=-7626/1870, 4-22=-7488/1881, 4-5=-6187/1618, 5-23=-7669/1948, 6-23=-7819/1937, 6-7=-9223/2334, 7-24=-9266/2331, 8-24=-9415/2320, 8-25=-9626/2583, 9-25=-9720/2560, 1-19=-8348/1897, 9-11=-7870/2118 BOT CHORD 19-26=-321/426, 18-26=-321/426, 18-27=-1515/6373, 17-27=-1515/6373, 17-28=-1578/6870, 16-28=-1578/6870, 15-16=-1373/6027, 15-29=-1373/6027, 14-29=-1373/6027, 14-30=-1679/7468, 13-30=-1679/7468, 13-31=-1968/7701, 12-31=-1968/7701, 11-12=-179/526 WEBS 2-18=-1265/311, 2-17=-242/778, 3-17=-448/1880, 3-16=-1885/569, 4-16=-962/3850, 4-14=-291/578, 5-14=-1110/4395, 6-14=-2665/912, 6-13=-862/2816, 8-13=-575/464, 8-12=-400/554, 1-18=-1542/7031, 9-12=-1860/7417 NOTES 1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows: Top chords connected as follows: 2x4 - 2 rows staggered at 0-6-0 oc, 2x6 - 2 rows staggered at 0-9-0 oc. Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-6-0 oc. Web connected as follows: 2x4 - 1 row at 0-9-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Unbalanced roof live loads have been considered for this design. 4) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=5.0psf; BCDL=5.0psf; h=30ft; Cat. II; Exp C; Enclosed; MWFRS (envelope) exterior zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 5) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pg=20.0 psf; Pf=20.4 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10, Lu=50-0-0; Min. flat roof snow load governs. Rain surcharge applied to all exposed surfaces with slopes less than 0.500/12 in accordance with IBC 1608.3.4. 6) Unbalanced snow loads have been considered for this design. 7) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 15.4 psf on overhangs non-concurrent with other live loads. 8) Provide adequate drainage to prevent water ponding. 9) All plates are MT20 plates unless otherwise indicated. 10) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 11) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 2050 lb uplift at joint 19 and 2146 lb uplift at joint 11. Job Truss Truss Type Qty Ply DWH - Woodside at West Clay Lot 29 G03 1 22004899-12T Piggyback Base Girder Job Reference (optional) Run: 8.4 S 0 Apr 7 2020 Print: 8.400 S Apr 7 2020 MiTek Industries, Inc. Wed Jun 10 15:41:57 Page: 1 ID:OF9LW Leez4TNtvmZQczCsozX6h7-W 2iIbARwqV0giVpnu9Rh7GwB_cf?Vti6Y7wePzz7fHu Continued on page 2 07/07/20 William Hohlt DE Job # 73384-W2 1 Dansco Engineering, LLC Date: 06/11/2020 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. 12) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 13) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 14) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 1096 lb down and 259 lb up at 2-1-4, 1135 lb down and 262 lb up at 4-1-4, 1141 lb down and 260 lb up at 6-1-4, 1151 lb down and 271 lb up at 8-1-4, 1158 lb down and 273 lb up at 10-1-4, 1158 lb down and 273 lb up at 12-1-4, 1158 lb down and 273 lb up at 14-1-4, 1158 lb down and 274 lb up at 16-1-4, 1140 lb down and 260 lb up at 18-1-4, 1215 lb down and 272 lb up at 20-1-4, and 1114 lb down and 251 lb up at 22-1-4, and 1729 lb down and 848 lb up at 24-1-4 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. LOAD CASE(S) Standard 1) Dead + Snow (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (lb/ft) Vert: 1-4=-51, 4-5=-61, 5-9=-51, 9-10=-51, 11-19=-20 Concentrated Loads (lb) Vert: 18=-1135 (B), 17=-1151 (B), 16=-1158 (B), 14=-1158 (B), 13=-1215 (B), 12=-1693 (B), 26=-1096 (B), 27=-1141 (B), 28=-1158 (B), 29=-1158 (B), 30=-1140 (B), 31=-1114 (B) Job Truss Truss Type Qty Ply DWH - Woodside at West Clay Lot 29 G03 1 22004899-12T Piggyback Base Girder Job Reference (optional) Run: 8.4 S 0 Apr 7 2020 Print: 8.400 S Apr 7 2020 MiTek Industries, Inc. Wed Jun 10 15:41:57 Page: 2 ID:OF9LWLeez4TNtvmZQczCsozX6h7-W2iIbARwqV0giVpnu9Rh7GwB_cf?Vti6Y7wePzz7fHu 07/07/20 William Hohlt DE Job # 73384-W2 1 Dansco Engineering, LLC Date: 06/11/2020 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. 4x8 3x4 3x4 3x4 3x10 17 16 15 1426 25 24 22 1 2 21 20 19 18 3 5 6 7 8 9 10 11 12 134 T1 T2 T3 W7 W1 B1 B2 B3 B2 B4 W11 W10 W12 W10 W11 W14 W13 W7 W15 W7 W15 W2 W5 W4W3 W8 W7 W9 W6 W10 W10 Scale = 1:66 Plate Offsets (X, Y): [4:0-4-4,Edge], [9:0-2-0,0-2-0], [16:0-3-8,0-2-0], [18:0-3-8,0-2-8], [21:0-2-8,0-4-0], [23:0-4-0,0-4-12] Loading (psf) Spacing 2-0-0 CSI DEFL in (loc) l/defl L/d PLATES GRIP TCLL (roof) 20.0 Plate Grip DOL 1.15 TC 0.67 Vert(LL) 0.13 18-19 >999 360 MT20 197/144 Snow (Pf/Pg) 20.4/20.0 Lumber DOL 1.15 BC 0.63 Vert(CT) -0.18 18-19 >999 240 TCDL 10.0 Rep Stress Incr NO WB 0.83 Horz(CT) 0.05 14 n/a n/a BCLL 0.0 Code IRC2018/TPI2014 Matrix-MSH BCDL 10.0 Weight: 262 lb FT = 20% LUMBER TOP CHORD 2x6 SP 2400F 2.0E *Except* T1:2x4 SPF No.2 BOT CHORD 2x6 SP 2400F 2.0E *Except* B2:2x4 SPF Stud WEBS 2x4 SPF Stud *Except* W11:2x4 SPF No.2, W1:2x6 SPF No.2 BRACING TOP CHORD Structural wood sheathing directly applied or 7-6-1 oc purlins, except end verticals, and 2-0-0 oc purlins (5-11-9 max.): 4-13. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS (lb/size) 14=1595/ Mechanical, (min. 0-1-8), 23=3821/0-6-0, (min. 0-3-5), 26=-170/0-4-0, (min. 0-1-8) Max Horiz 26=192 (LC 52) Max Uplift 14=-838 (LC 8), 23=-2008 (LC 9), 26=-459 (LC 41) Max Grav 14=1713 (LC 33), 23=3993 (LC 33), 26=260 (LC 9) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-368/685, 3-27=-621/1209, 4-27=-617/1245, 4-28=-971/1904, 5-28=-968/1889, 5-6=-602/1165, 6-29=-1026/544, 29-30=-1026/544, 7-30=-1026/544, 7-31=-2279/1184, 31-32=-2279/1184, 8-32=-2279/1184, 8-33=-2279/1184, 9-33=-2279/1184, 9-34=-2279/1184, 10-34=-2279/1184, 10-35=-2970/1524, 11-35=-2970/1524, 11-36=-1305/682, 36-37=-1305/682, 12-37=-1305/682, 12-38=-1305/682, 38-39=-1305/682, 13-39=-1305/682, 13-14=-1629/828, 2-26=-217/443 BOT CHORD 25-40=-628/378, 40-41=-628/378, 24-41=-628/378, 24-42=-1134/604, 23-42=-1134/604, 6-21=-1991/1023, 21-43=-1038/547, 20-43=-1038/546, 20-44=-550/1012, 19-44=-550/1012, 19-45=-1563/3007, 18-45=-1565/3014, 16-47=-1031/2003, 47-48=-1031/2003, 15-48=-1031/2003 WEBS 6-20=-1293/2604, 7-20=-1480/779, 7-19=-832/1641, 8-19=-428/268, 10-19=-947/475, 16-18=-990/1923, 11-18=-670/1269, 11-16=-522/331, 11-15=-1081/545, 12-15=-497/315, 13-15=-944/1909, 2-25=-520/328, 4-24=-243/520, 3-24=-763/376, 3-25=-251/538, 5-21=-681/1348, 5-23=-1501/796, 21-23=-1960/1011, 4-23=-1498/774 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=5.0psf; BCDL=5.0psf; h=30ft; Cat. II; Exp C; Enclosed; MWFRS (envelope) exterior zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pg=20.0 psf; Pf=20.4 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10, Lu=50-0-0; Min. flat roof snow load governs. Rain surcharge applied to all exposed surfaces with slopes less than 0.500/12 in accordance with IBC 1608.3.4. 4) Unbalanced snow loads have been considered for this design. 5) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 15.4 psf on overhangs non-concurrent with other live loads. 6) Provide adequate drainage to prevent water ponding. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) Refer to girder(s) for truss to truss connections. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 838 lb uplift at joint 14, 459 lb uplift at joint 26 and 2008 lb uplift at joint 23. 10) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 11) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. Job Truss Truss Type Qty Ply DWH - Woodside at West Clay Lot 29 G04 1 12004899-12T Half Hip Girder Job Reference (optional) Run: 8.4 S 0 Apr 7 2020 Print: 8.400 S Apr 7 2020 MiTek Industries, Inc. Wed Jun 10 15:42:01 Page: 1 ID:l7sWIot7pjXJpDSSEuKQpVzX6i6-_FFhpWSYbp8WKeOzSsywgTTMv0zZEMEG nngBxQz7fHt Continued on page 2 07/07/20 William Hohlt DE Job # 73384-W2 1 Dansco Engineering, LLC Date: 06/11/2020 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. 12) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 68 lb down and 36 lb up at 6-1-4, 166 lb down and 113 lb up at 8-1-4, 170 lb down and 111 lb up at 10-1-4, 170 lb down and 111 lb up at 12-1-4, 152 lb down and 92 lb up at 14-1-4, 152 lb down and 92 lb up at 16-1-4, 152 lb down and 92 lb up at 18-1-4, 152 lb down and 92 lb up at 20-1-4, 152 lb down and 92 lb up at 22-1-4, 152 lb down and 92 lb up at 24-1-4, 170 lb down and 111 lb up at 26-1-4, 170 lb down and 111 lb up at 28-1-4, 170 lb down and 111 lb up at 30-1-4, and 170 lb down and 111 lb up at 32-1-4, and 170 lb down and 111 lb up at 34-1-4 on top chord, and 239 lb down and 148 lb up at 4-1-4, 102 lb down and 78 lb up at 6-1-4, 42 lb down and 52 lb up at 8-1-4, 50 lb down and 27 lb up at 10-1-4, 50 lb down and 27 lb up at 12-2-4, 69 lb down and 49 lb up at 14-1-4, 69 lb down and 49 lb up at 16-1-4, 69 lb down and 49 lb up at 18-1-4, 69 lb down and 49 lb up at 20-1-4, 69 lb down and 49 lb up at 22-1-4, 69 lb down and 49 lb up at 24-3-12, 50 lb down and 27 lb up at 26-1-4, 50 lb down and 27 lb up at 28-1-4, 50 lb down and 27 lb up at 30-1-4, and 50 lb down and 27 lb up at 32-1-4, and 50 lb down and 27 lb up at 34-1-4 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 13) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Snow (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (lb/ft) Vert: 1-2=-51, 2-4=-51, 4-13=-61, 22-26=-20, 18-21=-20, 14-17=-20 Concentrated Loads (lb) Vert: 22=-39 (B), 20=-61 (B), 6=-104 (B), 7=-87 (B), 8=-87 (B), 19=-61 (B), 10=-87 (B), 18=-61 (B), 5=-104 (B), 23=-39 (B), 27=-37 (B), 28=-104 (B), 30=-87 (B), 31=-87 (B), 33=-87 (B), 35=-104 (B), 36=-104 (B), 37=-104 (B), 38=-104 (B), 39=-104 (B), 40=-239 (B), 41=-101 (B), 42=-34 (B), 43=-61 (B), 44=-61 (B), 45=-61 (B), 46=-39 (B), 47=-39 (B), 48=-39 (B), 49=-39 (B), 50=-39 (B) Job Truss Truss Type Qty Ply DWH - Woodside at West Clay Lot 29 G04 1 12004899-12T Half Hip Girder Job Reference (optional) Run: 8.4 S 0 Apr 7 2020 Print: 8.400 S Apr 7 2020 MiTek Industries, Inc. Wed Jun 10 15:42:01 Page: 2 ID:l7sWIot7pjXJpDSSEuKQpVzX6i6-_FFhpWSYbp8WKeOzSsywgTTMv0zZEMEGnngBxQz7fHt 07/07/20 William Hohlt DE Job # 73384-W2 1 Dansco Engineering, LLC Date: 06/11/2020 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. 20 19 18 16 15 14 13 12 11 1 2 43 5 6 7 8 9 10 T1 T2 T4 T3 T5 W13 W1 B1 B3B2 W3 W4 W5 W11 W2 W7 W6 W13 W12 W12 W8 W9 W10 Scale = 1:66.2 Plate Offsets (X, Y): [2:0-2-15,0-2-0], [4:0-5-0,0-1-13], [8:0-4-0,0-2-8] Loading (psf) Spacing 2-0-0 CSI DEFL in (loc) l/defl L/d PLATES GRIP TCLL (roof) 20.0 Plate Grip DOL 1.15 TC 1.00 Vert(LL) 0.05 17-18 >999 360 MT20 197/144 Snow (Pf/Pg) 20.4/20.0 Lumber DOL 1.15 BC 0.47 Vert(CT) -0.14 11-12 >999 240 MT18HS 197/144 TCDL 10.0 Rep Stress Incr NO WB 0.81 Horz(CT) 0.01 11 n/a n/a BCLL 0.0 Code IRC2018/TPI2014 Matrix-MSH BCDL 10.0 Weight: 198 lb FT = 20% LUMBER TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 *Except* W3,W4,W5,W1,W2,W7,W6:2x4 SPF Stud BRACING TOP CHORD Structural wood sheathing directly applied or 5-10-12 oc purlins, except end verticals, and 2-0-0 oc purlins (3-1-0 max.): 3-4, 8-10. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. WEBS 1 Row at midpt 10-11, 8-13, 9-12, 8-12, 7-13 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS (lb/size) 11=961/0-6-0, (min. 0-1-14), 17=1388/0-6-0, (min. 0-2-11), 20=278/0-4-0, (min. 0-1-8) Max Horiz 20=419 (LC 12) Max Uplift 11=-268 (LC 97), 17=-427 (LC 12), 20=-129 (LC 8) Max Grav 11=1187 (LC 80), 17=1731 (LC 40), 20=419 (LC 40) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 3-4=-440/103, 6-22=-740/56, 7-22=-546/78, 7-8=-723/136, 8-23=-592/137, 9-23=-592/137, 9-10=-592/137, 10-11=-1124/296, 2-20=-401/114 BOT CHORD 19-20=-410/44, 18-19=-415/125, 17-18=-383/425, 14-15=-234/558, 13-14=-234/558, 12-13=-164/584 WEBS 3-18=-39/407, 6-17=-1468/420, 4-17=-532/332, 9-12=-728/272, 10-12=-243/1047, 6-15=-132/847, 7-15=-478/155, 7-13=-78/269 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=5.0psf; BCDL=5.0psf; h=30ft; Cat. II; Exp C; Enclosed; MWFRS (envelope) exterior zone; cantilever left exposed ; end vertical left exposed; porch left exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pg=20.0 psf; Pf=20.4 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10, Lu=50-0-0; Min. flat roof snow load governs. Rain surcharge applied to all exposed surfaces with slopes less than 0.500/12 in accordance with IBC 1608.3.4. 4) Unbalanced snow loads have been considered for this design. 5) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 15.4 psf on overhangs non-concurrent with other live loads. 6) Provide adequate drainage to prevent water ponding. 7) All plates are MT20 plates unless otherwise indicated. 8) All plates are 3x4 MT20 unless otherwise indicated. 9) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 268 lb uplift at joint 11, 129 lb uplift at joint 20 and 427 lb uplift at joint 17. 11) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 12) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 13) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 71 lb down and 129 lb up at 1-6-4, and 76 lb down and 135 lb up at 3-4-4 on top chord, and 12 lb down and 43 lb up at 1-6-4, and 11 lb down and 28 lb up at 3-4-4 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. LOAD CASE(S) Standard 1) Dead + Snow (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (lb/ft) Job Truss Truss Type Qty Ply DWH - Woodside at West Clay Lot 29 G05 1 12004899-12T Piggyback Base Girder Job Reference (optional) Run: 8.4 S 0 Mar 10 2020 Print: 8.400 S Apr 7 2020 MiTek Industries, Inc. Wed Jun 10 15:42:02 Page: 1 ID:qEdKW8O5zQwNvQ4C2mts0UzWm aO -t0VBetV3e1eyoGikhi0sqJdzpdM4AAUriPeP4Bz7fHp Continued on page 2 07/07/20 William Hohlt DE Job # 73384-W2 1 Dansco Engineering, LLC Date: 06/11/2020 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Vert: 1-2=-51, 2-3=-51, 3-4=-61, 4-8=-51, 8-10=-61, 11-20=-20 Concentrated Loads (lb) Vert: 3=42, 18=9, 4=44 Job Truss Truss Type Qty Ply DWH - Woodside at West Clay Lot 29 G05 1 12004899-12T Piggyback Base Girder Job Reference (optional) Run: 8.4 S 0 Mar 10 2020 Print: 8.400 S Apr 7 2020 MiTek Industries, Inc. Wed Jun 10 15:42:02 Page: 2 ID:qEdKW8O5zQwNvQ4C2mts0UzWmaO-t0VBetV3e1eyoGikhi0sqJdzpdM4AAUriPeP4Bz7fHp 07/07/20 William Hohlt DE Job # 73384-W2 1 Dansco Engineering, LLC Date: 06/11/2020 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. 912 25 14 13 1 28 29 122 3 11 4 10 26 30 27 5 9 6 8 7 W1 T1 T2 W2 B1 B2 ST5 ST5 ST6 ST6 ST4 ST3 ST2 ST1 ST4 ST3 ST2 ST7 Scale = 1:47.7 Loading (psf) Spacing 2-0-0 CSI DEFL in (loc) l/defl L/d PLATES GRIP TCLL (roof) 20.0 Plate Grip DOL 1.15 TC 0.31 Vert(LL) n/a - n/a 999 MT20 197/144 Snow (Pf/Pg) 15.4/20.0 Lumber DOL 1.15 BC 0.21 Vert(CT) n/a - n/a 999 TCDL 10.0 Rep Stress Incr YES WB 0.34 Horz(CT) 0.00 17 n/a n/a BCLL 0.0 Code IRC2018/TPI2014 Matrix-MSH BCDL 10.0 Weight: 120 lb FT = 20% LUMBER TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF Stud OTHERS 2x4 SPF Stud *Except* ST5:2x4 SPF No.2 BRACING TOP CHORD Structural wood sheathing directly applied or 10-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. JOINTS 1 Brace at Jt(s): 26, 27, 30 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS All bearings 21-3-2. (lb) - Max Horiz 25=273 (LC 15) Max Uplift All uplift 100 (lb) or less at joint(s) 19, 22, 23 except 15=-108 (LC 17), 16=-111 (LC 17), 17=-146 (LC 17), 20=-130 (LC 16), 24=-224 (LC 16), 25=-308 (LC 14) Max Grav All reactions 250 (lb) or less at joint(s) 16, 17, 20, 22, 23 except 15=390 (LC 2), 18=384 (LC 24), 19=384 (LC 30), 24=325 (LC 30), 25=308 (LC 13) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-296/320, 2-3=-215/259, 5-6=-128/281, 6-7=-122/252, 7-8=-122/252, 8-9=-102/263 WEBS 19-28=-313/75, 26-28=-313/75, 6-26=-262/71, 18-29=-317/0, 27-29=-317/0, 8-27=-277/0 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=5.0psf; BCDL=5.0psf; h=30ft; Cat. II; Exp C; Enclosed; MWFRS (envelope) exterior zone and C-C Corner(3E) 0-1-12 to 3-3-2, Exterior(2N) 3-3-2 to 11-3-2, Corner(3R) 11-3-2 to 14-3-2, Exterior(2N) 14-3-2 to 22-9-14 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pg=20.0 psf; Pf=15.4 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 5) Unbalanced snow loads have been considered for this design. 6) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 15.4 psf on overhangs non-concurrent with other live loads. 7) All plates are 1.5x4 MT20 unless otherwise indicated. 8) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 9) Vertical gable studs spaced at 2-0-0 oc and horizontal gable studs spaced at 3-9-8 oc. 10) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 11) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 19, 22, 23 except (jt=lb) 25=307, 20=130, 24=223, 17=145, 16=111, 15=107. 12) Non Standard bearing condition. Review required. 13) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. LOAD CASE(S) Standard Job Truss Truss Type Qty Ply DWH - Woodside at West Clay Lot 29 GE01 1 12004899-12T Common Supported Gable Job Reference (optional) Run: 8.4 S 0 Mar 10 2020 Print: 8.400 S Apr 7 2020 M iTek Industries, Inc. Wed Jun 10 15:42:03 Page: 1 ID:bvTaa2BtH2TeOTWoveaRCezW nmr-LC3asDWhPLmpQQHwEPX5NXAJK1mNvk4?x3Nycdz7fHo 07/07/20 William Hohlt DE Job # 73384-W2 1 Dansco Engineering, LLC Date: 06/11/2020 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. 612 55 29 1 2 3 4 56 7 28 8 27 9 26 10 25 11 24 12 23 13 2214 15 16 17 18 19 20 21 W1 T2 T1 T3 T4 T5 W3 B1 B1B2 W2ST1 ST2 ST3 ST4 ST5 ST6 ST7 ST8 ST9 ST10 ST11 ST11 ST11 ST11 ST11 ST11 ST11 ST10 ST9 ST8 ST7 ST6 ST5 Scale = 1:80.3 Plate Offsets (X, Y): [2:0-2-15,0-2-0], [5:0-2-13,0-1-8], [13:0-3-0,0-2-0], [22:0-3-0,0-2-0] Loading (psf) Spacing 2-0-0 CSI DEFL in (loc) l/defl L/d PLATES GRIP TCLL (roof) 20.0 Plate Grip DOL 1.15 TC 0.15 Vert(LL) n/a - n/a 999 MT20 197/144 Snow (Pf/Pg) 20.4/20.0 Lumber DOL 1.15 BC 0.02 Vert(CT) n/a - n/a 999 TCDL 10.0 Rep Stress Incr YES WB 0.18 Horz(CT) 0.00 29 n/a n/a BCLL 0.0 Code IRC2018/TPI2014 Matrix-MSH BCDL 10.0 Weight: 326 lb FT = 20% LUMBER TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF Stud OTHERS 2x4 SPF No.2 *Except* ST1,ST2,ST3,ST4,ST5,ST6:2x4 SPF Stud BRACING TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (10-0-0 max.): 13-22. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing, Except: 10-0-0 oc bracing: 34-35,33-34,32-33,31-32,30-31,29-30. WEBS 1 Row at midpt 11-47, 12-45, 13-44, 14-43, 15-42, 16-41, 17-40, 18-39, 19-37, 21-36, 22-35, 23-34, 24-33 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS All bearings 46-10-0. (lb) - Max Horiz 55=286 (LC 16) Max Uplift All uplift 100 (lb) or less at joint(s) 29, 30, 31, 32, 33, 34, 36, 37, 39, 40, 41, 42, 43, 45, 47, 48, 49, 50, 51, 52, 53, 55 except 54=-251 (LC 16) Max Grav All reactions 250 (lb) or less at joint(s) 29, 30, 31, 32, 33, 34, 35, 36, 37, 39, 40, 41, 42, 43, 44, 45, 47, 48, 49, 50, 51, 52, 53, 54 except 55=280 (LC 32) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-55=-266/71, 2-3=-292/85, 3-4=-258/90, 11-12=-83/271, 12-13=-101/321, 13-14=-90/307, 14-15=-90/307, 15-16=-90/307, 16-56=-90/307, 17-56=-90/307, 17-57=-90/307, 18-57=-90/307, 18-19=-90/307, 19-20=-90/307, 20-21=-90/307, 21-22=-90/307, 22-23=-101/321, 23-24=-84/271 BOT CHORD 54-55=-265/76 WEBS 2-54=-93/329 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=5.0psf; BCDL=5.0psf; h=30ft; Cat. II; Exp C; Enclosed; MWFRS (envelope) exterior zone and C-C Corner(3E) -1-2-12 to 3-6-4, Exterior(2N) 3-6-4 to 19-5-0, Corner(3R) 19-5-0 to 24-1-3, Exterior(2N) 24-1-3 to 35-7-8, Corner(3R) 35-7-8 to 40-3-11, Exterior(2N) 40-3-11 to 46-8-4 zone; cantilever left exposed ; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pg=20.0 psf; Pf=20.4 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10, Lu=50-0-0; Min. flat roof snow load governs. Rain surcharge applied to all exposed surfaces with slopes less than 0.500/12 in accordance with IBC 1608.3.4. 5) Unbalanced snow loads have been considered for this design. 6) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 15.4 psf on overhangs non-concurrent with other live loads. 7) Provide adequate drainage to prevent water ponding. 8) All plates are 2x4 MT20 unless otherwise indicated. 9) Gable requires continuous bottom chord bearing. 10) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 11) Gable studs spaced at 2-0-0 oc. 12) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. Job Truss Truss Type Qty Ply DWH - Woodside at West Clay Lot 29 GE02 1 12004899-12T Piggyback Base Supported Gable Job Reference (optional) Run: 8.4 S 0 Mar 10 2020 Print: 8.400 S Apr 7 2020 M iTek Industries, Inc. Wed Jun 10 15:42:03 Page: 1 ID:rjdhkN6B8i9i7IvbwJTVptzWnle-LC3asDW hPLmpQQHwEPX5NXALq1pLvna?x3Nycdz7fHo Continued on page 2 07/07/20 William Hohlt DE Job # 73384-W2 1 Dansco Engineering, LLC Date: 06/11/2020 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. 13) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 55, 29, 53, 52, 51, 50, 49, 48, 47, 45, 43, 42, 41, 40, 39, 37, 36, 34, 33, 32, 31, 30 except (jt=lb) 54=250. 14) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 15) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. LOAD CASE(S) Standard Job Truss Truss Type Qty Ply DWH - Woodside at West Clay Lot 29 GE02 1 12004899-12T Piggyback Base Supported Gable Job Reference (optional) Run: 8.4 S 0 Mar 10 2020 Print: 8.400 S Apr 7 2020 MiTek Industries, Inc. Wed Jun 10 15:42:03 Page: 2 ID:rjdhkN6B8i9i7IvbwJTVptzWnle-LC3asDWhPLmpQQHwEPX5NXALq1pLvna?x3Nycdz7fHo 07/07/20 William Hohlt DE Job # 73384-W2 1 Dansco Engineering, LLC Date: 06/11/2020 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. 312 612 1 14 2 3 4 5 6 7 8 9 10 11 12 13 T2 T1 T3 W1 B2 B1 ST8 ST7 ST6 ST5 ST4 ST3 ST2 ST1 Scale = 1:43 Loading (psf) Spacing 2-0-0 CSI DEFL in (loc) l/defl L/d PLATES GRIP TCLL (roof) 20.0 Plate Grip DOL 1.15 TC 0.17 Vert(LL) n/a - n/a 999 MT20 197/144 Snow (Pf/Pg) 15.4/20.0 Lumber DOL 1.15 BC 0.11 Vert(CT) n/a - n/a 999 TCDL 10.0 Rep Stress Incr YES WB 0.07 Horz(CT) 0.00 2 n/a n/a BCLL 0.0 Code IRC2018/TPI2014 Matrix-MSH BCDL 10.0 Weight: 82 lb FT = 20% LUMBER TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF Stud OTHERS 2x4 SPF Stud BRACING TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS All bearings 20-6-0. (lb) - Max Horiz 2=255 (LC 16), 24=255 (LC 16) Max Uplift All uplift 100 (lb) orless at joint(s) 2, 14, 15, 16, 17, 19, 20, 21, 22, 24 except 23=-136 (LC 16) Max Grav All reactions 250 (lb) or less at joint(s) 2, 14, 15, 16, 17, 19, 20, 21, 22, 24 except 23=350 (LC 2) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-284/107 NOTES 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=5.0psf; BCDL=5.0psf; h=30ft; Cat. II; Exp C; Enclosed; MWFRS (envelope) exterior zone and C-C Corner(3E) -1-2-12 to 1-9-4, Exterior(2N) 1-9-4 to 20-4-4 zone; cantilever left exposed ; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pg=20.0 psf; Pf=15.4 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10; Min. flat roof snow load governs. 4) Unbalanced snow loads have been considered for this design. 5) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 15.4 psf on overhangs non-concurrent with other live loads. 6) All plates are 1.5x4 MT20 unless otherwise indicated. 7) Gable requires continuous bottom chord bearing. 8) Gable studs spaced at 2-0-0 oc. 9) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 14, 15, 16, 17, 19, 20, 21, 22, 2, 2 except (jt=lb) 23=135. 11) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. LOAD CASE(S) Standard Job Truss Truss Type Qty Ply DWH - Woodside at West Clay Lot 29 GE03 1 12004899-12T Roof Special Supported Gable Job Reference (optional) Run: 8.4 S 0 Mar 10 2020 Print: 8.400 S Apr 7 2020 MiTek Industries, Inc. Wed Jun 10 15:42:04 Page: 1 ID:Rm66WEJHq7efVW zdDckiKlzWnk5-pPdy3ZXJAfug2Zs7o73KvkjWGR8AeFY89j7W83z7fHn 07/07/20 William Hohlt DE Job # 73384-W2 1 Dansco Engineering, LLC Date: 06/11/2020 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. 6 12 3x4 MT18HS 3x10 3x5 5 4 1 2 3 W1 T1 W2 B1 Scale = 1:30.7 Plate Offsets (X, Y): [4:0-3-8,Edge] Loading (psf) Spacing 2-0-0 CSI DEFL in (loc) l/defl L/d PLATES GRIP TCLL (roof) 20.0 Plate Grip DOL 1.15 TC 0.49 Vert(LL) 0.12 4-5 >556 360 MT20 197/144 Snow (Pf/Pg) 15.4/20.0 Lumber DOL 1.15 BC 0.38 Vert(CT) 0.10 4-5 >652 240 MT18HS 197/144 TCDL 10.0 Rep Stress Incr YES WB 0.00 Horz(CT) 0.00 4 n/a n/a BCLL 0.0 Code IRC2018/TPI2014 Matrix-MR BCDL 10.0 Weight: 19 lb FT = 20% LUMBER TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF Stud BRACING TOP CHORD Structural wood sheathing directly applied or 5-8-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS (lb/size) 4=185/ Mechanical, (min. 0-1-8), 5=248/0-4-0, (min. 0-1-8) Max Horiz 5=120 (LC 16) Max Uplift 4=-105 (LC 16), 5=-50 (LC 13) Max Grav 4=261 (LC 23), 5=306 (LC 23) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-5=-269/193 NOTES 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=5.0psf; BCDL=5.0psf; h=30ft; Cat. II; Exp C; Enclosed; MWFRS (envelope) exterior zone and C-C Exterior(2E) -0-10-12 to 2-1-4, Interior (1) 2-1-4 to 5-6-4 zone; cantilever left exposed ; end vertical left exposed; porch left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pg=20.0 psf; Pf=15.4 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 3) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 15.4 psf on overhangs non-concurrent with other live loads. 5) All plates are MT20 plates unless otherwise indicated. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) Refer to girder(s) for truss to truss connections. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 50 lb uplift at joint 5 and 105 lb uplift at joint 4. 9) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. LOAD CASE(S) Standard Job Truss Truss Type Qty Ply DWH - Woodside at West Clay Lot 29 J01 2 12004899-12T Jack-Closed Job Reference (optional) Run: 8.4 S 0 Mar 10 2020 Print: 8.400 S Apr 7 2020 M iTek Industries, Inc. Wed Jun 10 15:42:04 Page: 1 ID:dSPt_K1octyRtGspHDsW3ezWoM U-pPdy3ZXJAfug2Zs7o73KvkjRGR4yeGe89j7W83z7fHn 07/07/20 William Hohlt DE Job # 73384-W2 1 Dansco Engineering, LLC Date: 06/11/2020 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. 6 12 3x4 3x4 5 4 1 2 3 W1 T1 B1 Scale = 1:25.2 Loading (psf) Spacing 2-0-0 CSI DEFL in (loc) l/defl L/d PLATES GRIP TCLL (roof) 20.0 Plate Grip DOL 1.15 TC 0.18 Vert(LL) 0.01 4-5 >999 360 MT20 197/144 Snow (Pf/Pg) 15.4/20.0 Lumber DOL 1.15 BC 0.12 Vert(CT) 0.01 4-5 >999 240 TCDL 10.0 Rep Stress Incr YES WB 0.00 Horz(CT) -0.01 3 n/a n/a BCLL 0.0 Code IRC2018/TPI2014 Matrix-MR BCDL 10.0 Weight: 8 lb FT = 20% LUMBER TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF Stud BRACING TOP CHORD Structural wood sheathing directly applied or 2-7-3 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS (lb/size) 3=50/ Mechanical, (min. 0-1-8), 4=23/ Mechanical, (min. 0-1-8), 5=149/0-4-0, (min. 0-1-8) Max Horiz 5=60 (LC 13) Max Uplift 3=-52 (LC 16), 4=-22 (LC 13), 5=-27 (LC 16) Max Grav 3=72 (LC 23), 4=45 (LC 7), 5=208 (LC 23) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=5.0psf; BCDL=5.0psf; h=30ft; Cat. II; Exp C; Enclosed; MWFRS (envelope) exterior zone and C-C Exterior(2E) -0-10-12 to 2-1-4, Interior (1) 2-1-4 to 2-6-7 zone; cantilever left exposed ; end vertical left exposed; porch left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pg=20.0 psf; Pf=15.4 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 3) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 15.4 psf on overhangs non-concurrent with other live loads. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) Refer to girder(s) for truss to truss connections. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 27 lb uplift at joint 5, 52 lb uplift at joint 3 and 22 lb uplift at joint 4. 8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. LOAD CASE(S) Standard Job Truss Truss Type Qty Ply DWH - Woodside at West Clay Lot 29 J02 1 12004899-12T Jack-Open Job Reference (optional) Run: 8.4 S 0 Mar 10 2020 Print: 8.400 S Apr 7 2020 M iTek Industries, Inc. Wed Jun 10 15:42:05 Page: 1 ID:PLX1V798iSgFXYThEF1KKFzWoL1-HbAKHvXxxy0XfjRJMqaZSyFhsrUFNjuHONs3hWz7fHm 07/07/20 William Hohlt DE Job # 73384-W2 1 Dansco Engineering, LLC Date: 06/11/2020 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. 4.99 12 3x4 7 5 1 2 3 4 W1 T1 B1 W2 Scale = 1:30 Loading (psf) Spacing 2-0-0 CSI DEFL in (loc) l/defl L/d PLATES GRIP TCLL (roof) 20.0 Plate Grip DOL 1.15 TC 0.53 Vert(LL) 0.05 5-6 >999 360 MT20 197/144 Snow (Pf/Pg) 15.4/20.0 Lumber DOL 1.15 BC 0.37 Vert(CT) 0.04 5-6 >999 240 TCDL 10.0 Rep Stress Incr NO WB 0.05 Horz(CT) -0.12 4 n/a n/a BCLL 0.0 Code IRC2018/TPI2014 Matrix-MP BCDL 10.0 Weight: 19 lb FT = 20% LUMBER TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF Stud BRACING TOP CHORD Structural wood sheathing directly applied or 5-5-1 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS (lb/size) 4=84/ Mechanical, (min. 0-1-8), 5=24/ Mechanical, (min. 0-1-8), 6=269/0-7-3, (min. 0-1-8) Max Horiz 6=93 (LC 11) Max Uplift 4=-86 (LC 12), 5=-44 (LC 9), 6=-165 (LC 8) Max Grav 4=136 (LC 19), 5=76 (LC 7), 6=348 (LC 19) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=5.0psf; BCDL=5.0psf; h=30ft; Cat. II; Exp C; Enclosed; MWFRS (envelope) exterior zone; cantilever left exposed ; end vertical left exposed; porch left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pg=20.0 psf; Pf=15.4 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 3) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 15.4 psf on overhangs non-concurrent with other live loads. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) Refer to girder(s) for truss to truss connections. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 86 lb uplift at joint 4, 44 lb uplift at joint 5 and 165 lb uplift at joint 6. 8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 35 lb down and 58 lb up at 1-11-3, and 85 lb down and 46 lb up at 3-1-2 on top chord, and 7 lb down and 33 lb up at 1-11-3, and 27 lb down and 42 lb up at 3-1-2 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 10) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Snow (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (lb/ft) Vert: 1-2=-51 Concentrated Loads (lb) Vert: 10=-1, 11=-1 Trapezoidal Loads (lb/ft) Vert: 2=-2 (F=24, B=24)-to-3=-10 (F=20, B=20), 3=-10 (F=20, B=20)-to-8=-25 (F=13, B=13), 8=-25 (F=13, B=13)-to-9=-40 (F=6, B=6), 9=-40 (F=6, B=6)- to-4=-69 (F=-9, B=-9), 7=0 (F=10, B=10)-to-6=-3 (F=8, B=8), 6=-3 (F=8, B=8)-to-10=-9 (F=5, B=5), 10=-9 (F=5, B=5)-to-11=-15 (F=2, B=2), 11=-15 (F=2, B=2)- to-5=-27 (F=-4, B=-4) Job Truss Truss Type Qty Ply DWH - Woodside at West Clay Lot 29 J03 1 12004899-12T Jack-Open Girder Job Reference (optional) Run: 8.4 S 0 Mar 10 2020 Print: 8.400 S Apr 7 2020 M iTek Industries, Inc. Wed Jun 10 15:42:05 Page: 1 ID:m7vCFHqGWfjIF9lSW ?1Sc2zWoK9-HbAKHvXxxy0XfjR JMqaZSyFbPrQKNj6HONs3hWz7fHm 07/07/20 William Hohlt DE Job # 73384-W2 1 Dansco Engineering, LLC Date: 06/11/2020 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. 9 12 3x4 3x5 5 4 1 2 3 W1 T1 B1 Scale = 1:27 Loading (psf) Spacing 2-0-0 CSI DEFL in (loc) l/defl L/d PLATES GRIP TCLL (roof) 20.0 Plate Grip DOL 1.15 TC 0.37 Vert(LL) 0.00 4-5 >999 360 MT20 197/144 Snow (Pf/Pg) 15.4/20.0 Lumber DOL 1.15 BC 0.16 Vert(CT) 0.00 4-5 >999 240 TCDL 10.0 Rep Stress Incr YES WB 0.00 Horz(CT) -0.02 3 n/a n/a BCLL 0.0 Code IRC2018/TPI2014 Matrix-MR BCDL 10.0 Weight: 8 lb FT = 20% LUMBER TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF Stud BRACING TOP CHORD Structural wood sheathing directly applied or 1-8-2 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS (lb/size) 3=13/ Mechanical, (min. 0-1-8), 4=9/ Mechanical, (min. 0-1-8), 5=155/0-4-0, (min. 0-1-8) Max Horiz 5=77 (LC 13) Max Uplift 3=-51 (LC 16), 4=-37 (LC 13), 5=-9 (LC 12) Max Grav 3=34 (LC 30), 4=27 (LC 7), 5=229 (LC 23) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=5.0psf; BCDL=5.0psf; h=30ft; Cat. II; Exp C; Enclosed; MWFRS (envelope) exterior zone and C-C Exterior(2E) zone; cantilever left exposed ; end vertical left exposed; porch left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pg=20.0 psf; Pf=15.4 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 3) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 15.4 psf on overhangs non-concurrent with other live loads. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) Refer to girder(s) for truss to truss connections. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 9 lb uplift at joint 5, 37 lb uplift at joint 4 and 51 lb uplift at joint 3. 8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. LOAD CASE(S) Standard Job Truss Truss Type Qty Ply DWH - Woodside at West Clay Lot 29 J04 1 12004899-12T Jack-Open Job Reference (optional) Run: 8.4 S 0 Mar 10 2020 Print: 8.400 S Apr 7 2020 M iTek Industries, Inc. Wed Jun 10 15:42:05 Page: 1 ID:X6LNoOWyegS_89lS_YaMYazWoKZ-HbAKHvXxxy0XfjRJM qaZSyFeurTdNjuHONs3hWz7fHm 07/07/20 William Hohlt DE Job # 73384-W2 1 Dansco Engineering, LLC Date: 06/11/2020 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. 9 12 =3x6 5 4 1 2 3 W1 T1 B1 Scale = 1:27.2 Loading (psf) Spacing 2-0-0 CSI DEFL in (loc) l/defl L/d PLATES GRIP TCLL (roof) 20.0 Plate Grip DOL 1.15 TC 0.40 Vert(LL) 0.06 4-5 >899 360 MT20 197/144 Snow (Pf/Pg) 15.4/20.0 Lumber DOL 1.15 BC 0.47 Vert(CT) 0.05 4-5 >999 240 TCDL 10.0 Rep Stress Incr YES WB 0.00 Horz(CT) -0.09 3 n/a n/a BCLL 0.0 Code IRC2018/TPI2014 Matrix-MR BCDL 10.0 Weight: 15 lb FT = 20% LUMBER TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x6 SPF No.2 BRACING TOP CHORD Structural wood sheathing directly applied or 4-8-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS (lb/size) 3=98/ Mechanical, (min. 0-1-8), 4=50/ Mechanical, (min. 0-1-8), 5=219/0-6-0, (min. 0-1-8) Max Horiz 5=152 (LC 16) Max Uplift 3=-122 (LC 16), 4=-17 (LC 16) Max Grav 3=165 (LC 23), 4=83 (LC 7), 5=278 (LC 23) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=5.0psf; BCDL=5.0psf; h=30ft; Cat. II; Exp C; Enclosed; MWFRS (envelope) exterior zone and C-C Exterior(2E) -0-10-12 to 2-1-4, Interior (1) 2-1-4 to 4-7-4 zone; cantilever left exposed ; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pg=20.0 psf; Pf=15.4 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 3) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 15.4 psf on overhangs non-concurrent with other live loads. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) Refer to girder(s) for truss to truss connections. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 122 lb uplift at joint 3 and 17 lb uplift at joint 4. 8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. LOAD CASE(S) Standard Job Truss Truss Type Qty Ply DWH - Woodside at West Clay Lot 29 J05 7 12004899-12T Jack-Open Job Reference (optional) Run: 8.4 S 0 Apr 7 2020 Print: 8.400 S Apr 7 2020 MiTek Industries, Inc. Wed Jun 10 15:42:05 Page: 1 ID:MH9IjLAB8lontxf4H8TyF6zX3US-HbAKHvXxxy0XfjRJMqaZSyFdOrOlNjuHONs3hWz7fHm 07/07/20 William Hohlt DE Job # 73384-W2 1 Dansco Engineering, LLC Date: 06/11/2020 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. 3x4 3x4 3x6 8 7 1 6 5 2 3 4 W1 T1 B1 B2 B3 W2 Scale = 1:32.6 Loading (psf) Spacing 2-0-0 CSI DEFL in (loc) l/defl L/d PLATES GRIP TCLL (roof) 20.0 Plate Grip DOL 1.15 TC 0.25 Vert(LL) 0.05 5-6 >999 360 MT20 197/144 Snow (Pf/Pg) 15.4/20.0 Lumber DOL 1.15 BC 0.29 Vert(CT) -0.06 7 >971 240 TCDL 10.0 Rep Stress Incr YES WB 0.00 Horz(CT) -0.04 4 n/a n/a BCLL 0.0 Code IRC2018/TPI2014 Matrix-MR BCDL 10.0 Weight: 20 lb FT = 20% LUMBER TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 *Except* B2:2x4 SPF Stud WEBS 2x4 SPF Stud BRACING TOP CHORD Structural wood sheathing directly applied or 4-8-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS (lb/size) 4=92/ Mechanical, (min. 0-1-8), 5=60/ Mechanical, (min. 0-1-8), 8=217/0-6-0, (min. 0-1-8) Max Horiz 8=154 (LC 16) Max Uplift 4=-100 (LC 16), 5=-39 (LC 16) Max Grav 4=148 (LC 23), 5=81 (LC 23), 8=274 (LC 23) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=5.0psf; BCDL=5.0psf; h=30ft; Cat. II; Exp C; Enclosed; MWFRS (envelope) exterior zone and C-C Exterior(2E) -0-10-12 to 2-3-3, Interior (1) 2-3-3 to 4-7-4 zone; cantilever left exposed ; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pg=20.0 psf; Pf=15.4 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 3) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 15.4 psf on overhangs non-concurrent with other live loads. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) Refer to girder(s) for truss to truss connections. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint 4 and 39 lb uplift at joint 5. 8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. LOAD CASE(S) Standard Job Truss Truss Type Qty Ply DWH - Woodside at West Clay Lot 29 J06 6 12004899-12T Jack-Open Job Reference (optional) Run: 8.4 S 0 Apr 7 2020 Print: 8.400 S Apr 7 2020 MiTek Industries, Inc. Wed Jun 10 15:42:05 Page: 1 ID:RsNauhqmfMWuYWs9g9V9orzWoHa-HbAKHvXxxy0XfjRJM qaZSyFgkrRXNjuHONs3hWz7fHm 07/07/20 William Hohlt DE Job # 73384-W2 1 Dansco Engineering, LLC Date: 06/11/2020 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. 9 12 5x6 5 4 1 2 3 W1 T1 B1 Scale = 1:27.2 Loading (psf) Spacing 2-0-0 CSI DEFL in (loc) l/defl L/d PLATES GRIP TCLL (roof) 20.0 Plate Grip DOL 1.15 TC 0.50 Vert(LL) 0.10 4-5 >503 360 MT20 197/144 Snow (Pf/Pg) 15.4/20.0 Lumber DOL 1.15 BC 0.48 Vert(CT) 0.09 4-5 >557 240 TCDL 10.0 Rep Stress Incr YES WB 0.00 Horz(CT) -0.13 3 n/a n/a BCLL 0.0 Code IRC2018/TPI2014 Matrix-MR BCDL 10.0 Weight: 14 lb FT = 20% LUMBER TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF Stud BRACING TOP CHORD Structural wood sheathing directly applied or 4-6-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS (lb/size) 3=97/ Mechanical, (min. 0-1-8), 4=47/ Mechanical, (min. 0-1-8), 5=222/0-4-0, (min. 0-1-8) Max Horiz 5=151 (LC 16) Max Uplift 3=-124 (LC 16), 4=-42 (LC 13), 5=-4 (LC 13) Max Grav 3=165 (LC 23), 4=82 (LC 7), 5=281 (LC 23) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=5.0psf; BCDL=5.0psf; h=30ft; Cat. II; Exp C; Enclosed; MWFRS (envelope) exterior zone and C-C Exterior(2E) -1-0-12 to 1-11-4, Interior (1) 1-11-4 to 4-5-4 zone; cantilever left exposed ; end vertical left exposed; porch left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pg=20.0 psf; Pf=15.4 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 3) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 15.4 psf on overhangs non-concurrent with other live loads. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) Refer to girder(s) for truss to truss connections. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 4 lb uplift at joint 5, 124 lb uplift at joint 3 and 42 lb uplift at joint 4. 8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. LOAD CASE(S) Standard Job Truss Truss Type Qty Ply DWH - Woodside at West Clay Lot 29 J07 1 12004899-12T Jack-Open Job Reference (optional) Run: 8.4 S 0 Apr 7 2020 Print: 8.400 S Apr 7 2020 MiTek Industries, Inc. Wed Jun 10 15:42:06 Page: 1 ID:MH9IjLAB8lontxf4H8TyF6zX3US-mnkiUFYaiG8OHt?VwY5o_9ondFks6A7Rd1ccDyz7fHl 07/07/20 William Hohlt DE Job # 73384-W2 1 Dansco Engineering, LLC Date: 06/11/2020 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. 5x6 3x4 1.5x4 =4x4 7 6 5 1 2 3 W1 T1 T2 B1 W2 0-1-11 Scale = 1:35.7 Loading (psf) Spacing 2-0-0 CSI DEFL in (loc) l/defl L/d PLATES GRIP TCLL (roof) 20.0 Plate Grip DOL 1.15 TC 0.52 Vert(LL) 0.06 6-7 >895 360 MT20 197/144 Snow (Pf/Pg) 20.4/20.0 Lumber DOL 1.15 BC 0.35 Vert(CT) 0.05 6-7 >999 240 TCDL 10.0 Rep Stress Incr YES WB 0.04 Horz(CT) -0.12 4 n/a n/a BCLL 0.0 Code IRC2018/TPI2014 Matrix-MP BCDL 10.0 Weight: 18 lb FT = 20% LUMBER TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF Stud BRACING TOP CHORD Structural wood sheathing directly applied or 4-6-0 oc purlins, except end verticals, and 2-0-0 oc purlins: 3-4. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS (lb/size) 4=74/ Mechanical, (min. 0-1-8), 5=76/ Mechanical, (min. 0-1-8), 7=223/0-4-0, (min. 0-1-8) Max Horiz 7=124 (LC 16) Max Uplift 4=-33 (LC 16), 5=-68 (LC 16), 7=-14 (LC 16) Max Grav 4=88 (LC 37), 5=121 (LC 38), 7=376 (LC 38) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-7=-319/131 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=5.0psf; BCDL=5.0psf; h=30ft; Cat. II; Exp C; Enclosed; MWFRS (envelope) exterior zone and C-C Exterior(2E) -1-0-12 to 1-11-4, Interior (1) 1-11-4 to 3-8-11, Exterior(2E) 3-8-11 to 4-5-4 zone; cantilever left exposed ; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pg=20.0 psf; Pf=20.4 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10, Lu=50-0-0; Min. flat roof snow load governs. Rain surcharge applied to all exposed surfaces with slopes less than 0.500/12 in accordance with IBC 1608.3.4. 4) Unbalanced snow loads have been considered for this design. 5) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 15.4 psf on overhangs non-concurrent with other live loads. 6) Provide adequate drainage to prevent water ponding. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) Refer to girder(s) for truss to truss connections. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 14 lb uplift at joint 7, 33 lb uplift at joint 4 and 68 lb uplift at joint 5. 10) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 11) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. LOAD CASE(S) Standard Job Truss Truss Type Qty Ply DWH - Woodside at West Clay Lot 29 J08 1 12004899-12T Jack-Open Job Reference (optional) Run: 8.4 S 0 Apr 7 2020 Print: 8.400 S Apr 7 2020 MiTek Industries, Inc. Wed Jun 10 15:42:06 Page: 1 ID:CTxRqKfH4kmWw HiVfoyLgBzWnxr-mnkiUFYaiG8OHt?VwY5o_9om NFmp6AYRd1ccDyz7fHl 07/07/20 William Hohlt DE Job # 73384-W2 1 Dansco Engineering, LLC Date: 06/11/2020 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. 3x4 3x5 = 3x4 =5x6 =3x4 3x4 7 6 5 1 2 43 W1 T1 T2 W5 B1 W2 W3 W4 0-1-11 Scale = 1:26.3 Plate Offsets (X, Y): [3:0-3-0,0-2-2] Loading (psf) Spacing 2-0-0 CSI DEFL in (loc) l/defl L/d PLATES GRIP TCLL (roof) 20.0 Plate Grip DOL 1.15 TC 0.16 Vert(LL) 0.00 6 >999 360 MT20 197/144 Snow (Pf/Pg) 20.4/20.0 Lumber DOL 1.15 BC 0.06 Vert(CT) 0.00 5-6 >999 240 TCDL 10.0 Rep Stress Incr NO WB 0.06 Horz(CT) 0.00 5 n/a n/a BCLL 0.0 Code IRC2018/TPI2014 Matrix-MP BCDL 10.0 Weight: 26 lb FT = 20% LUMBER TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF Stud BRACING TOP CHORD Structural wood sheathing directly applied or 4-6-0 oc purlins, except end verticals, and 2-0-0 oc purlins: 3-4. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS (lb/size) 5=226/ Mechanical, (min. 0-1-8), 7=284/0-4-0, (min. 0-1-8) Max Horiz 7=82 (LC 12) Max Uplift 5=-138 (LC 9), 7=-109 (LC 12) Max Grav 5=259 (LC 33), 7=401 (LC 34) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-7=-384/116 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=5.0psf; BCDL=5.0psf; h=30ft; Cat. II; Exp C; Enclosed; MWFRS (envelope) exterior zone; cantilever left exposed ; end vertical left exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pg=20.0 psf; Pf=20.4 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10, Lu=50-0-0; Min. flat roof snow load governs. Rain surcharge applied to all exposed surfaces with slopes less than 0.500/12 in accordance with IBC 1608.3.4. 4) Unbalanced snow loads have been considered for this design. 5) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 15.4 psf on overhangs non-concurrent with other live loads. 6) Provide adequate drainage to prevent water ponding. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) Refer to girder(s) for truss to truss connections. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 109 lb uplift at joint 7 and 138 lb uplift at joint 5. 10) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 11) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 12) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 140 lb down and 165 lb up at 2-4-11 on top chord, and 66 lb down and 35 lb up at 2-4-11 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 13) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Snow (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (lb/ft) Vert: 1-2=-51, 2-3=-51, 3-4=-61, 5-7=-20 Concentrated Loads (lb) Vert: 6=0 (F), 3=-107 (F), 8=-24 (F) Job Truss Truss Type Qty Ply DWH - Woodside at West Clay Lot 29 J09 1 12004899-12T Jack-Closed Girder Job Reference (optional) Run: 8.4 S 0 Apr 7 2020 Print: 8.400 S Apr 7 2020 MiTek Industries, Inc. Wed Jun 10 15:42:06 Page: 1 ID:5pL5UtKIhYKy8f3xuO3AqOzWo2j-mnkiUFYaiG8OHt?Vw Y5o_9osxFrU6AFRd1ccDyz7fHl 07/07/20 William Hohlt DE Job # 73384-W2 1 Dansco Engineering, LLC Date: 06/11/2020 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. 4.99 12 3x4 5 4 1 2 3 W1 T1 B1 Scale = 1:24.8 Loading (psf) Spacing 2-0-0 CSI DEFL in (loc) l/defl L/d PLATES GRIP TCLL (roof) 20.0 Plate Grip DOL 1.15 TC 0.36 Vert(LL) -0.02 4-5 >999 360 MT20 197/144 Snow (Pf/Pg) 15.4/20.0 Lumber DOL 1.15 BC 0.15 Vert(CT) -0.02 4-5 >999 240 TCDL 10.0 Rep Stress Incr NO WB 0.00 Horz(CT) -0.04 3 n/a n/a BCLL 0.0 Code IRC2018/TPI2014 Matrix-MR BCDL 10.0 Weight: 14 lb FT = 20% LUMBER TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF Stud BRACING TOP CHORD Structural wood sheathing directly applied or 4-2-1 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS (lb/size) 3=34/ Mechanical, (min. 0-1-8), 4=17/ Mechanical, (min. 0-1-8), 5=129/0-6-1, (min. 0-1-8) Max Horiz 5=85 (LC 11) Max Uplift 3=-57 (LC 12), 4=-16 (LC 30), 5=-127 (LC 8) Max Grav 3=79 (LC 19), 4=57 (LC 7), 5=215 (LC 19) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=5.0psf; BCDL=5.0psf; h=30ft; Cat. II; Exp C; Enclosed; MWFRS (envelope) exterior zone; cantilever left exposed ; end vertical left exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pg=20.0 psf; Pf=15.4 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 3) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 15.4 psf on overhangs non-concurrent with other live loads. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) Refer to girder(s) for truss to truss connections. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 127 lb uplift at joint 5, 57 lb uplift at joint 3 and 16 lb uplift at joint 4. 8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 75 lb down and 164 lb up at 0-9-14, and 68 lb down and 117 lb up at 1-10-2 on top chord, and 11 lb down and 18 lb up at 0-9-14, and 32 lb down and 35 lb up at 1-10-2 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 10) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Snow (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (lb/ft) Vert: 1-2=-51 Concentrated Loads (lb) Vert: 7=43 (F), 8=30 (B), 9=1 (F), 10=1 (B) Trapezoidal Loads (lb/ft) Vert: 2=-2 (F=24, B=24)-to-7=-11 (F=20, B=20), 7=-11 (F=20, B=20)-to-8=-24 (F=14, B=14), 8=-24 (F=14, B=14)-to-3=-53 (F=-1, B=-1), 5=0 (F=10, B=10)- to-9=-4 (F=8, B=8), 9=-4 (F=8, B=8)-to-10=-9 (F=6, B=6), 10=-9 (F=6, B=6)-to-4=-21 (F=0, B=0) Job Truss Truss Type Qty Ply DWH - Woodside at West Clay Lot 29 J10 1 12004899-12T Jack-Open Girder Job Reference (optional) Run: 8.4 S 0 Apr 7 2020 Print: 8.400 S Apr 7 2020 MiTek Industries, Inc. Wed Jun 10 15:42:06 Page: 1 ID:zn?Kcompm6Pd?Rzve0j8QUzWo3S-mnkiUFYaiG8OHt?VwY5o_9opmFp26A7Rd1ccDyz7fHl 07/07/20 William Hohlt DE Job # 73384-W2 1 Dansco Engineering, LLC Date: 06/11/2020 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. 9 12 3x4 3x4 5 4 1 2 3 W1 T1 B1 Scale = 1:21.7 Loading (psf) Spacing 2-0-0 CSI DEFL in (loc) l/defl L/d PLATES GRIP TCLL (roof) 20.0 Plate Grip DOL 1.15 TC 0.27 Vert(LL) 0.00 4-5 >999 360 MT20 197/144 Snow (Pf/Pg) 15.4/20.0 Lumber DOL 1.15 BC 0.08 Vert(CT) 0.00 4-5 >999 240 TCDL 10.0 Rep Stress Incr YES WB 0.00 Horz(CT) -0.01 3 n/a n/a BCLL 0.0 Code IRC2018/TPI2014 Matrix-MR BCDL 10.0 Weight: 5 lb FT = 20% LUMBER TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF Stud BRACING TOP CHORD Structural wood sheathing directly applied or 0-11-12 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS (lb/size) 3=-16/ Mechanical, (min. 0-1-8), 4=0/ Mechanical, (min. 0-1-8), 5=136/0-4-0, (min. 0-1-8) Max Horiz 5=59 (LC 13) Max Uplift 3=-51 (LC 22), 4=-32 (LC 13), 5=-3 (LC 12) Max Grav 3=16 (LC 14), 4=35 (LC 14), 5=192 (LC 23) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=5.0psf; BCDL=5.0psf; h=30ft; Cat. II; Exp C; Enclosed; MWFRS (envelope) exterior zone and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pg=20.0 psf; Pf=15.4 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 3) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 15.4 psf on overhangs non-concurrent with other live loads. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) Refer to girder(s) for truss to truss connections. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 3 lb uplift at joint 5, 32 lb uplift at joint 4 and 51 lb uplift at joint 3. 8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. LOAD CASE(S) Standard Job Truss Truss Type Qty Ply DWH - Woodside at West Clay Lot 29 J11 1 12004899-12T Jack-Open Job Reference (optional) Run: 8.4 S 0 Apr 7 2020 Print: 8.400 S Apr 7 2020 MiTek Industries, Inc. Wed Jun 10 15:42:07 Page: 1 ID:aI?C 6bvH3ln_ZKM3APnr9Lz7gcV-E_I4hbZCTaGFv1aiTFc1XNL?1e9IrdNashLAlOz7fHk 07/07/20 William Hohlt DE Job # 73384-W2 1 Dansco Engineering, LLC Date: 06/11/2020 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. 3x4 3x4 5 4 1 2 W1 T1 B1 Scale = 1:26.1 Loading (psf) Spacing 2-0-0 CSI DEFL in (loc) l/defl L/d PLATES GRIP TCLL (roof) 20.0 Plate Grip DOL 1.15 TC 0.18 Vert(LL) 0.00 4-5 >999 360 MT20 197/144 Snow (Pf/Pg) 15.4/20.0 Lumber DOL 1.15 BC 0.05 Vert(CT) 0.00 4-5 >999 240 TCDL 10.0 Rep Stress Incr YES WB 0.00 Horz(CT) 0.00 3 n/a n/a BCLL 0.0 Code IRC2018/TPI2014 Matrix-MR BCDL 10.0 Weight: 5 lb FT = 20% LUMBER TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF Stud BRACING TOP CHORD Structural wood sheathing directly applied or 1-1-2 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS (lb/size) 3=-18/ Mechanical, (min. 0-1-8), 4=0/ Mechanical, (min. 0-1-8), 5=154/0-4-0, (min. 0-1-8) Max Horiz 5=48 (LC 13) Max Uplift 3=-57 (LC 22), 4=-15 (LC 13), 5=-37 (LC 16) Max Grav 3=7 (LC 12), 4=14 (LC 14), 5=213 (LC 22) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=5.0psf; BCDL=5.0psf; h=30ft; Cat. II; Exp C; Enclosed; MWFRS (envelope) exterior zone and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pg=20.0 psf; Pf=15.4 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 3) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 15.4 psf on overhangs non-concurrent with other live loads. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) Refer to girder(s) for truss to truss connections. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 37 lb uplift at joint 5, 15 lb uplift at joint 4 and 57 lb uplift at joint 3. 8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. LOAD CASE(S) Standard Job Truss Truss Type Qty Ply DWH - Woodside at West Clay Lot 29 J12 1 12004899-12T Jack-Open Job Reference (optional) Run: 8.4 S 0 Apr 7 2020 Print: 8.400 S Apr 7 2020 MiTek Industries, Inc. Wed Jun 10 15:42:07 Page: 1 ID:oCu0Rg2ELAJMGzDKULdXsKzWo35-E_I4hbZCTaGFv1aiTFc1XNL1QeAsrdNashLAlOz7fHk 07/07/20 William Hohlt DE Job # 73384-W2 1 Dansco Engineering, LLC Date: 06/11/2020 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. 6 12 3x4 4x4 5 4 1 2 3 W1 T1 B1 Scale = 1:23.4 Loading (psf) Spacing 2-0-0 CSI DEFL in (loc) l/defl L/d PLATES GRIP TCLL (roof) 20.0 Plate Grip DOL 1.15 TC 0.38 Vert(LL) 0.02 4-5 >999 360 MT20 197/144 Snow (Pf/Pg) 15.4/20.0 Lumber DOL 1.15 BC 0.23 Vert(CT) -0.02 4-5 >999 240 TCDL 10.0 Rep Stress Incr YES WB 0.00 Horz(CT) -0.04 3 n/a n/a BCLL 0.0 Code IRC2018/TPI2014 Matrix-MR BCDL 10.0 Weight: 12 lb FT = 20% LUMBER TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF Stud BRACING TOP CHORD Structural wood sheathing directly applied or 4-0-8 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS (lb/size) 3=84/ Mechanical, (min. 0-1-8), 4=39/ Mechanical, (min. 0-1-8), 5=218/0-4-0, (min. 0-1-8) Max Horiz 5=91 (LC 16) Max Uplift 3=-80 (LC 16), 5=-41 (LC 16) Max Grav 3=132 (LC 23), 4=72 (LC 7), 5=299 (LC 23) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-5=-266/193 NOTES 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=5.0psf; BCDL=5.0psf; h=30ft; Cat. II; Exp C; Enclosed; MWFRS (envelope) exterior zone and C-C Exterior(2E) -1-2-12 to 1-9-4, Interior (1) 1-9-4 to 3-11-12 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pg=20.0 psf; Pf=15.4 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10; Min. flat roof snow load governs. Rain surcharge applied to all exposed surfaces with slopes less than 0.500/12 in accordance with IBC 1608.3.4. 3) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 15.4 psf on overhangs non-concurrent with other live loads. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) Refer to girder(s) for truss to truss connections. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 41 lb uplift at joint 5 and 80 lb uplift at joint 3. 8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. LOAD CASE(S) Standard Job Truss Truss Type Qty Ply DWH - Woodside at West Clay Lot 29 J13 1 12004899-12T Jack-Open Job Reference (optional) Run: 8.4 S 0 Apr 7 2020 Print: 8.400 S Apr 7 2020 MiTek Industries, Inc. Wed Jun 10 15:42:07 Page: 1 ID:Qh7HKq5J?c3cViUlFG 9d4UzWo?9-E_I4hbZCTaG Fv1aiTFc1XNL_Ce7yrdNashLAlOz7fHk 07/07/20 William Hohlt DE Job # 73384-W2 1 Dansco Engineering, LLC Date: 06/11/2020 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. 4.99 12 3x4 3x4 5 4 1 2 W1 T1 B1 Scale = 1:24.7 Loading (psf) Spacing 2-0-0 CSI DEFL in (loc) l/defl L/d PLATES GRIP TCLL (roof) 20.0 Plate Grip DOL 1.15 TC 0.19 Vert(LL) 0.00 4-5 >999 360 MT20 197/144 Snow (Pf/Pg) 15.4/20.0 Lumber DOL 1.15 BC 0.05 Vert(CT) 0.00 4-5 >999 240 TCDL 10.0 Rep Stress Incr NO WB 0.00 Horz(CT) 0.00 3 n/a n/a BCLL 0.0 Code IRC2018/TPI2014 Matrix-MR BCDL 10.0 Weight: 7 lb FT = 20% LUMBER TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF Stud BRACING TOP CHORD Structural wood sheathing directly applied or 1-8-5 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS (lb/size) 3=-15/ Mechanical, (min. 0-1-8), 4=-4/ Mechanical, (min. 0-1-8), 5=118/0-7-3, (min. 0-1-8) Max Horiz 5=51 (LC 11) Max Uplift 3=-45 (LC 16), 4=-27 (LC 11), 5=-77 (LC 8) Max Grav 3=22 (LC 8), 4=15 (LC 7), 5=180 (LC 18) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=5.0psf; BCDL=5.0psf; h=30ft; Cat. II; Exp C; Enclosed; MWFRS (envelope) exterior zone; cantilever left exposed ; end vertical left exposed; porch left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pg=20.0 psf; Pf=15.4 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 3) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 15.4 psf on overhangs non-concurrent with other live loads. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) Refer to girder(s) for truss to truss connections. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 77 lb uplift at joint 5, 27 lb uplift at joint 4 and 45 lb uplift at joint 3. 8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Snow (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (lb/ft) Vert: 1-2=-51 Trapezoidal Loads (lb/ft) Vert: 2=-2 (F=24, B=24)-to-3=-21 (F=15, B=15), 5=0 (F=10, B=10)-to-4=-8 (F=6, B=6) Job Truss Truss Type Qty Ply DWH - Woodside at West Clay Lot 29 J14 1 12004899-12T Jack-Open Girder Job Reference (optional) Run: 8.4 S 0 Mar 10 2020 Print: 8.400 S Apr 7 2020 M iTek Industries, Inc. Wed Jun 10 15:42:07 Page: 1 ID:5wXDQKHzZcLYDkltPyoO0FzWnqa-E_I4hbZCTaGFv1aiTFc1XNL1DeAordNashLAlOz7fHk 07/07/20 William Hohlt DE Job # 73384-W2 1 Dansco Engineering, LLC Date: 06/11/2020 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. 4.99 12 3x4 3x4 5 4 1 2 W1 T1 B1 Scale = 1:18.5 Loading (psf) Spacing 2-0-0 CSI DEFL in (loc) l/defl L/d PLATES GRIP TCLL (roof) 20.0 Plate Grip DOL 1.15 TC 0.24 Vert(LL) 0.00 4-5 >999 360 MT20 197/144 Snow (Pf/Pg) 15.4/20.0 Lumber DOL 1.15 BC 0.06 Vert(CT) 0.00 4-5 >999 240 TCDL 10.0 Rep Stress Incr NO WB 0.00 Horz(CT) -0.01 3 n/a n/a BCLL 0.0 Code IRC2018/TPI2014 Matrix-MR BCDL 10.0 Weight: 7 lb FT = 20% LUMBER TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF Stud BRACING TOP CHORD Structural wood sheathing directly applied or 1-8-5 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS (lb/size) 3=-21/ Mechanical, (min. 0-1-8), 4=-6/ Mechanical, (min. 0-1-8), 5=135/1-6-1, (min. 0-1-8) Max Horiz 5=52 (LC 11) Max Uplift 3=-48 (LC 18), 4=-16 (LC 27), 5=-72 (LC 8) Max Grav 3=27 (LC 8), 4=14 (LC 7), 5=207 (LC 18) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=5.0psf; BCDL=5.0psf; h=30ft; Cat. II; Exp C; Enclosed; MWFRS (envelope) exterior zone; cantilever left exposed ; end vertical left exposed; porch left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pg=20.0 psf; Pf=15.4 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 3) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 15.4 psf on overhangs non-concurrent with other live loads. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) Refer to girder(s) for truss to truss connections. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 72 lb uplift at joint 5, 16 lb uplift at joint 4 and 48 lb uplift at joint 3. 8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Snow (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (lb/ft) Vert: 1-2=-51 Trapezoidal Loads (lb/ft) Vert: 2=-2 (F=24, B=24)-to-3=-21 (F=15, B=15), 5=0 (F=10, B=10)-to-4=-8 (F=6, B=6) Job Truss Truss Type Qty Ply DWH - Woodside at West Clay Lot 29 J15 1 12004899-12T Jack-Open Girder Job Reference (optional) Run: 8.4 S 0 Mar 10 2020 Print: 8.400 S Apr 7 2020 M iTek Industries, Inc. Wed Jun 10 15:42:07 Page: 1 ID :ZOc1BUVFK8d_NV7KSk7cl1zWnqI-E_I4hbZCTaGFv1aiTFc1XNL0ReAfrdNashLAlOz7fHk 07/07/20 William Hohlt DE Job # 73384-W2 1 Dansco Engineering, LLC Date: 06/11/2020 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. = 3x4 =3x4 =3x4 1 5 42 3 T1 T1 B1 Scale = 1:23.2 Plate Offsets (X, Y): [3:0-2-0,Edge] Loading (psf) Spacing 2-0-0 CSI DEFL in (loc) l/defl L/d PLATES GRIP TCLL (roof) 20.0 Plate Grip DOL 1.15 TC 0.02 Vert(LL) n/a - n/a 999 MT20 197/144 Snow (Pf/Pg) 15.4/20.0 Lumber DOL 1.15 BC 0.03 Vert(CT) n/a - n/a 999 TCDL 10.0 Rep Stress Incr YES WB 0.00 Horz(CT) 0.00 10 n/a n/a BCLL 0.0 Code IRC2018/TPI2014 Matrix-MP BCDL 10.0 Weight: 8 lb FT = 20% LUMBER TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 BRACING TOP CHORD Structural wood sheathing directly applied or 3-9-5 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS All bearings 2-4-11. (lb) - Max Horiz 2=33 (LC 15), 6=33 (LC 15) Max Uplift All uplift 100 (lb) or less at joint(s) 2, 4, 6, 10 Max Grav All reactions 250 (lb) or less at joint(s) 2, 4, 6, 10 FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=5.0psf; BCDL=5.0psf; h=30ft; Cat. II; Exp C; Enclosed; MWFRS (envelope) exterior zone and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pg=20.0 psf; Pf=15.4 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 5) Unbalanced snow loads have been considered for this design. 6) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 15.4 psf on overhangs non-concurrent with other live loads. 7) Gable requires continuous bottom chord bearing. 8) Gable studs spaced at 4-0-0 oc. 9) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 4, 2, 4. 11) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 12) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building designer. LOAD CASE(S) Standard Job Truss Truss Type Qty Ply DWH - Woodside at West Clay Lot 29 P01 18 12004899-12T Piggyback Job Reference (optional) Run: 8.4 S 0 Apr 7 2020 Print: 8.400 S Apr 7 2020 MiTek Industries, Inc. Wed Jun 10 15:42:07 Page: 1 ID:6cgHyLCRSD2O6p7YSe18UzzWy0i-E_I4hbZCTaGFv1aiTFc1XNL3oeA8rdNashLAlOz7fHk 07/07/20 William Hohlt DE Job # 73384-W2 1 Dansco Engineering, LLC Date: 06/11/2020 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. = 3x4 =3x4 =3x4 1 5 42 3 T1 T1 B1 Scale = 1:23.2 Plate Offsets (X, Y): [3:0-2-0,Edge] Loading (psf) Spacing 2-0-0 CSI DEFL in (loc) l/defl L/d PLATES GRIP TCLL (roof) 20.0 Plate Grip DOL 1.15 TC 0.01 Vert(LL) n/a - n/a 999 MT20 197/144 Snow (Pf/Pg) 15.4/20.0 Lumber DOL 1.15 BC 0.01 Vert(CT) n/a - n/a 999 TCDL 10.0 Rep Stress Incr YES WB 0.00 Horz(CT) 0.00 10 n/a n/a BCLL 0.0 Code IRC2018/TPI2014 Matrix-MP BCDL 10.0 Weight: 16 lb FT = 20% LUMBER TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 BRACING TOP CHORD Structural wood sheathing directly applied or 3-9-5 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS All bearings 2-4-11. (lb) - Max Horiz 2=33 (LC 15), 6=33 (LC 15) Max Uplift All uplift 100 (lb) or less at joint(s) 2, 4, 6, 10 Max Grav All reactions 250 (lb) or less at joint(s) 2, 4, 6, 10 FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES 1) 2-ply truss to be connected together as follows: Top chords connected with 10d (0.131"x3") nails as follows: 2x4 - 1 row at 0-9-0 oc. Bottom chords connected with 10d (0.131"x3") nails as follows: 2x4 - 1 row at 0-9-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Unbalanced roof live loads have been considered for this design. 4) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=5.0psf; BCDL=5.0psf; h=30ft; Cat. II; Exp C; Enclosed; MWFRS (envelope) exterior zone and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 5) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 6) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pg=20.0 psf; Pf=15.4 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 7) Unbalanced snow loads have been considered for this design. 8) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 15.4 psf on overhangs non-concurrent with other live loads. 9) Gable requires continuous bottom chord bearing. 10) Gable studs spaced at 4-0-0 oc. 11) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 12) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 4, 2, 4. 13) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 14) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building designer. LOAD CASE(S) Standard Job Truss Truss Type Qty Ply DWH - Woodside at West Clay Lot 29 P02 1 22004899-12T Piggyback Job Reference (optional) Run: 8.4 S 0 Apr 7 2020 Print: 8.400 S Apr 7 2020 MiTek Industries, Inc. Wed Jun 10 15:42:08 Page: 1 ID:xm1ZCOGC13pYqkaipv7YjEzW y0c-iAsTvxaqEtO6WB9u1y7G4atEl2Wba4dk4K5jHqz7fHj 07/07/20 William Hohlt DE Job # 73384-W2 1 Dansco Engineering, LLC Date: 06/11/2020 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. 612 = 3x10 =4x6 =3x5 4x4 11 1 10 9 8 7 6 5 2 4 3 T1 T2 W1B1 ST3 ST2 ST1 ST2 ST1 Scale = 1:35.4 Plate Offsets (X, Y): [2:0-10-0,0-0-10] Loading (psf) Spacing 2-0-0 CSI DEFL in (loc) l/defl L/d PLATES GRIP TCLL (roof) 20.0 Plate Grip DOL 1.15 TC 0.54 Vert(LL) n/a - n/a 999 MT20 197/144 Snow (Pf/Pg) 15.4/20.0 Lumber DOL 1.15 BC 0.68 Vert(CT) n/a - n/a 999 TCDL 10.0 Rep Stress Incr YES WB 0.00 Horz(CT) 0.01 5 n/a n/a BCLL 0.0 Code IRC2018/TPI2014 Matrix-MR BCDL 10.0 Weight: 46 lb FT = 20% LUMBER TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF Stud OTHERS 2x4 SPF Stud BRACING TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS All bearings 12-11-15. (lb) - Max Horiz 2=80 (LC 15), 16=80 (LC 15) Max Uplift All uplift 100 (lb) or less at joint(s) 6, 9 except 2=-106 (LC 16), 5=-139 (LC 17), 10=-111 (LC 16), 16=-106 (LC 16) Max Grav All reactions 250 (lb) or less at joint(s) 6, 7, 8, 9 except 2=364 (LC 2), 5=434 (LC 2), 10=291 (LC 23), 16=364 (LC 2) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-20=-500/299, 20-21=-406/305, 3-21=-403/319, 3-22=-406/318, 22-23=-407/304, 4-23=-488/297, 4-5=-376/252 BOT CHORD 2-10=-222/363, 9-10=-222/363, 8-9=-222/363, 7-8=-222/363, 6-7=-222/363, 5-6=-222/363 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=5.0psf; BCDL=5.0psf; h=30ft; Cat. II; Exp C; Enclosed; MWFRS (envelope) exterior zone and C-C Exterior(2E) 0-4-3 to 3-4-3, Interior (1) 3-4-3 to 8-1-4, Exterior(2R) 8-1-4 to 11-1-4, Interior (1) 11-1-4 to 14-1-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pg=20.0 psf; Pf=15.4 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 5) Unbalanced snow loads have been considered for this design. 6) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 15.4 psf on overhangs non-concurrent with other live loads. 7) All plates are 1.5x4 MT20 unless otherwise indicated. 8) Gable requires continuous bottom chord bearing. 9) Gable studs spaced at 2-0-0 oc. 10) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 11) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 9, 6 except (jt=lb) 2=105, 5=139, 10=110, 2=105. 12) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 13) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building designer. LOAD CASE(S) Standard Job Truss Truss Type Qty Ply DWH - Woodside at West Clay Lot 29 P03 1 12004899-12T Piggyback Job Reference (optional) Run: 8.4 S 0 Apr 7 2020 Print: 8.400 S Apr 7 2020 MiTek Industries, Inc. Wed Jun 10 15:42:08 Page: 1 ID:iraR0lnY8z5asBomGjuPQ5zW y?y-iAsTvxaqEtO6WB9u1y7G4at6X2M 9a4dk4K5jHqz7fHj 07/07/20 William Hohlt DE Job # 73384-W2 1 Dansco Engineering, LLC Date: 06/11/2020 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. = 3x4 1.5x4 =4x4 1.5x4 1.5x4 1.5x4 3x4 11 1 10 9 8 7 2 6 53 4 T1 T2 W1B1 ST2 ST1 ST1 Scale = 1:35.4 Loading (psf) Spacing 2-0-0 CSI DEFL in (loc) l/defl L/d PLATES GRIP TCLL (roof) 20.0 Plate Grip DOL 1.15 TC 0.19 Vert(LL) n/a - n/a 999 MT20 197/144 Snow (Pf/Pg) 15.4/20.0 Lumber DOL 1.15 BC 0.10 Vert(CT) n/a - n/a 999 TCDL 10.0 Rep Stress Incr YES WB 0.07 Horz(CT) 0.00 7 n/a n/a BCLL 0.0 Code IRC2018/TPI2014 Matrix-MSH BCDL 10.0 Weight: 41 lb FT = 20% LUMBER TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF Stud OTHERS 2x4 SPF Stud BRACING TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS All bearings 12-11-15. (lb) - Max Horiz 2=80 (LC 15), 12=80 (LC 15) Max Uplift All uplift 100 (lb) or less at joint(s) 2, 7, 12 except 8=-139 (LC 17), 10=-144 (LC 16) Max Grav All reactions 250 (lb) or less at joint(s) 2, 7, 12 except 8=358 (LC 24), 9=294 (LC 2), 10=380 (LC 23) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 3-10=-303/224, 5-8=-293/220 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=5.0psf; BCDL=5.0psf; h=30ft; Cat. II; Exp C; Enclosed; MWFRS (envelope) exterior zone and C-C Exterior(2E) 0-4-3 to 3-4-3, Interior (1) 3-4-3 to 8-1-4, Exterior(2R) 8-1-4 to 11-1-4, Interior (1) 11-1-4 to 14-1-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pg=20.0 psf; Pf=15.4 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 5) Unbalanced snow loads have been considered for this design. 6) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 15.4 psf on overhangs non-concurrent with other live loads. 7) Gable requires continuous bottom chord bearing. 8) Gable studs spaced at 4-0-0 oc. 9) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 7, 2 except (jt=lb) 10=143, 8=139. 11) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 12) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building designer. LOAD CASE(S) Standard Job Truss Truss Type Qty Ply DWH - Woodside at West Clay Lot 29 P04 8 12004899-12T Piggyback Job Reference (optional) Run: 8.4 S 0 Apr 7 2020 Print: 8.400 S Apr 7 2020 MiTek Industries, Inc. Wed Jun 10 15:42:09 Page: 1 ID:xZdrvquB1kEJRa_VI6YWI_zWy?p-AMQr6GaS?BW z8Lk4bgeVcoQMgSrXJWotJ_qGqHz7fHi 07/07/20 William Hohlt DE Job # 73384-W2 1 Dansco Engineering, LLC Date: 06/11/2020 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. 612 = 3x4 1.5x4 = 4x4 1.5x4 =4x4 1.5x4 1.5x4 1.5x4 3x4 15 1 14 13 12 11 10 9 2 843 75 6 T1 T2 T3 T4 W3 B1 W1 W2 ST2 ST1 ST10-1-14 Scale = 1:39.2 Loading (psf) Spacing 2-0-0 CSI DEFL in (loc) l/defl L/d PLATES GRIP TCLL (roof) 20.0 Plate Grip DOL 1.15 TC 0.22 Vert(LL) n/a - n/a 999 MT20 197/144 Snow (Pf/Pg) 20.4/20.0 Lumber DOL 1.15 BC 0.10 Vert(CT) n/a - n/a 999 TCDL 10.0 Rep Stress Incr YES WB 0.08 Horz(CT) 0.00 9 n/a n/a BCLL 0.0 Code IRC2018/TPI2014 Matrix-MSH BCDL 10.0 Weight: 47 lb FT = 20% LUMBER TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF Stud OTHERS 2x4 SPF Stud BRACING TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 3-4. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing, Except: 6-0-0 oc bracing: 2-14. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS All bearings 14-9-15. (lb) - Max Horiz 2=80 (LC 15), 16=80 (LC 15) Max Uplift All uplift 100 (lb) or less at joint(s) 2, 9, 13, 14, 16 except 10=-140 (LC 17), 12=-136 (LC 16) Max Grav All reactions 250 (lb) or less at joint(s) 2, 9, 13, 14, 16 except 10=357 (LC 47), 11=300 (LC 2), 12=409 (LC 43) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 5-12=-343/208, 7-10=-293/205 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=5.0psf; BCDL=5.0psf; h=30ft; Cat. II; Exp C; Enclosed; MWFRS (envelope) exterior zone and C-C Exterior(2E) 0-4-3 to 4-7-8, Interior (1) 4-7-8 to 9-11-4, Exterior(2R) 9-11-4 to 12-11-4, Interior (1) 12-11-4 to 15-11-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pg=20.0 psf; Pf=20.4 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10, Lu=50-0-0; Min. flat roof snow load governs. Rain surcharge applied to all exposed surfaces with slopes less than 0.500/12 in accordance with IBC 1608.3.4. 5) Unbalanced snow loads have been considered for this design. 6) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 15.4 psf on overhangs non-concurrent with other live loads. 7) Provide adequate drainage to prevent water ponding. 8) Gable requires continuous bottom chord bearing. 9) Gable studs spaced at 4-0-0 oc. 10) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 11) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 9, 14, 13, 2 except (jt=lb) 12=136, 10=139. 12) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 13) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building designer. 14) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. LOAD CASE(S) Standard Job Truss Truss Type Qty Ply DWH - Woodside at West Clay Lot 29 P05 1 12004899-12T Piggyback Job Reference (optional) Run: 8.4 S 0 Apr 7 2020 Print: 8.400 S Apr 7 2020 MiTek Industries, Inc. Wed Jun 10 15:42:09 Page: 1 ID:TBekPwVYF5XDRFo6DcREJXzWy?1-AMQr6GaS?BWz8Lk4bgeVcoQMISrTJWgtJ_qGqHz7fHi 07/07/20 William Hohlt DE Job # 73384-W2 1 Dansco Engineering, LLC Date: 06/11/2020 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. = 3x4 1.5x4 = 4x6 =4x4 1.5x4 =4x4 1.5x4 1.5x4 1.5x4 3x4 13 1 12 11 10 9 8 2 7 6 43 5 T1 T2 T3 T4 W2 B1 W1 ST2 ST1 ST3 0-1-14 Scale = 1:39.2 Plate Offsets (X, Y): [2:0-2-0,Edge] Loading (psf) Spacing 2-0-0 CSI DEFL in (loc) l/defl L/d PLATES GRIP TCLL (roof) 20.0 Plate Grip DOL 1.15 TC 0.31 Vert(LL) n/a - n/a 999 MT20 197/144 Snow (Pf/Pg) 20.4/20.0 Lumber DOL 1.15 BC 0.29 Vert(CT) n/a - n/a 999 TCDL 10.0 Rep Stress Incr YES WB 0.07 Horz(CT) 0.00 2 n/a n/a BCLL 0.0 Code IRC2018/TPI2014 Matrix-MSH BCDL 10.0 Weight: 49 lb FT = 20% LUMBER TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF Stud OTHERS 2x4 SPF Stud BRACING TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 3-4. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS All bearings 14-9-15. (lb) - Max Horiz 2=80 (LC 15), 14=80 (LC 15) Max Uplift All uplift 100 (lb) or less at joint(s) 2, 8, 11, 14 except 9=-139 (LC 17), 12=-119 (LC 16) Max Grav All reactions 250 (lb) or less at joint(s) 8, 11 except 2=288 (LC 43), 9=357 (LC 49), 10=262 (LC 49), 12=418 (LC 43), 14=288 (LC 43) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 3-12=-252/159, 6-9=-292/208 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=5.0psf; BCDL=5.0psf; h=30ft; Cat. II; Exp C; Enclosed; MWFRS (envelope) exterior zone and C-C Exterior(2E) 0-4-3 to 3-4-3, Interior (1) 3-4-3 to 5-9-8, Exterior(2E) 5-9-8 to 7-7-8, Interior (1) 7-7-8 to 9-11-4, Exterior(2R) 9-11-4 to 12-11-4, Interior (1) 12-11-4 to 15-11-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pg=20.0 psf; Pf=20.4 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10, Lu=50-0-0; Min. flat roof snow load governs. Rain surcharge applied to all exposed surfaces with slopes less than 0.500/12 in accordance with IBC 1608.3.4. 5) Unbalanced snow loads have been considered for this design. 6) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 15.4 psf on overhangs non-concurrent with other live loads. 7) Provide adequate drainage to prevent water ponding. 8) Gable requires continuous bottom chord bearing. 9) Gable studs spaced at 4-0-0 oc. 10) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 11) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 8, 11, 2 except (jt=lb) 12=118, 9=138. 12) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 13) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building designer. 14) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. LOAD CASE(S) Standard Job Truss Truss Type Qty Ply DWH - Woodside at West Clay Lot 29 P06 1 12004899-12T Piggyback Job Reference (optional) Run: 8.4 S 0 Apr 7 2020 Print: 8.400 S Apr 7 2020 MiTek Industries, Inc. Wed Jun 10 15:42:09 Page: 1 ID:ykrFSKXV?WN0mTNeGg_PofzW xzh-AMQr6GaS?BW z8Lk4bgeVcoQLvSoTJWstJ_qGqHz7fHi 07/07/20 William Hohlt DE Job # 73384-W2 1 Dansco Engineering, LLC Date: 06/11/2020 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. 612 = 3x4 1.5x4 = 4x4 1.5x4 =4x4 1.5x4 1.5x4 1.5x4 3x4 15 1 14 13 12 11 10 9 2 8 3 4 5 7 6 T1 T2 T3 T4 W1 B1 W1 W2 ST2 ST1 ST1 0-1-14 Scale = 1:38.1 Loading (psf) Spacing 2-0-0 CSI DEFL in (loc) l/defl L/d PLATES GRIP TCLL (roof) 20.0 Plate Grip DOL 1.15 TC 0.22 Vert(LL) n/a - n/a 999 MT20 197/144 Snow (Pf/Pg) 20.4/20.0 Lumber DOL 1.15 BC 0.10 Vert(CT) n/a - n/a 999 TCDL 10.0 Rep Stress Incr YES WB 0.08 Horz(CT) 0.00 9 n/a n/a BCLL 0.0 Code IRC2018/TPI2014 Matrix-MSH BCDL 10.0 Weight: 47 lb FT = 20% LUMBER TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF Stud OTHERS 2x4 SPF Stud BRACING TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 3-4. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing, Except: 6-0-0 oc bracing: 2-14. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS All bearings 14-9-15. (lb) - Max Horiz 2=80 (LC 15), 16=80 (LC 15) Max Uplift All uplift 100 (lb) or less at joint(s) 2, 9, 13, 14, 16 except 10=-140 (LC 17), 12=-143 (LC 16) Max Grav All reactions 250 (lb) or less at joint(s) 2, 9, 13, 14, 16 except 10=357 (LC 24), 11=297 (LC 2), 12=434 (LC 43) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 5-12=-362/221, 7-10=-293/205 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=5.0psf; BCDL=5.0psf; h=30ft; Cat. II; Exp C; Enclosed; MWFRS (envelope) exterior zone and C-C Exterior(2E) 0-4-3 to 4-11-4, Interior (1) 4-11-4 to 9-11-4, Exterior(2R) 9-11-4 to 12-11-4, Interior (1) 12-11-4 to 15-11-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pg=20.0 psf; Pf=20.4 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10, Lu=50-0-0; Min. flat roof snow load governs. Rain surcharge applied to all exposed surfaces with slopes less than 0.500/12 in accordance with IBC 1608.3.4. 5) Unbalanced snow loads have been considered for this design. 6) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 15.4 psf on overhangs non-concurrent with other live loads. 7) Provide adequate drainage to prevent water ponding. 8) Gable requires continuous bottom chord bearing. 9) Gable studs spaced at 4-0-0 oc. 10) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 11) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 9, 14, 13, 2 except (jt=lb) 12=143, 10=139. 12) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 13) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building designer. 14) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. LOAD CASE(S) Standard Job Truss Truss Type Qty Ply DWH - Woodside at West Clay Lot 29 P07 1 12004899-12T Piggyback Job Reference (optional) Run: 8.4 S 0 Apr 7 2020 Print: 8.400 S Apr 7 2020 MiTek Industries, Inc. Wed Jun 10 15:42:10 Page: 1 ID:5JEtS1W JwPaW_w3CW BxPalzWxyQ-eY_DKcb4mVeqmUJH9N9k9?zXvsBj2zs1YeaqM jz7fHh 07/07/20 William Hohlt DE Job # 73384-W2 1 Dansco Engineering, LLC Date: 06/11/2020 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. = 3x4 1.5x4 1.5x4 =4x4 1.5x4 1.5x4 =3x4 1 7 10 9 8 62 3 5 4 T1 T1 B1 ST2 ST1 ST1 Scale = 1:33.1 Loading (psf) Spacing 2-0-0 CSI DEFL in (loc) l/defl L/d PLATES GRIP TCLL (roof) 20.0 Plate Grip DOL 1.15 TC 0.19 Vert(LL) n/a - n/a 999 MT20 197/144 Snow (Pf/Pg) 15.4/20.0 Lumber DOL 1.15 BC 0.10 Vert(CT) n/a - n/a 999 TCDL 10.0 Rep Stress Incr YES WB 0.07 Horz(CT) 0.00 6 n/a n/a BCLL 0.0 Code IRC2018/TPI2014 Matrix-MSH BCDL 10.0 Weight: 44 lb FT = 20% LUMBER TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF Stud BRACING TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS All bearings 14-3-6. (lb) - Max Horiz 2=71 (LC 16), 11=71 (LC 16) Max Uplift All uplift 100 (lb) or less at joint(s) 2, 6, 11, 15 except 8=-143 (LC 17), 10=-144 (LC 16) Max Grav All reactions 250 (lb) or less at joint(s) 2, 6, 11, 15 except 8=381 (LC 24), 9=271 (LC 2), 10=381 (LC 23) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 3-10=-304/215, 5-8=-304/215 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=5.0psf; BCDL=5.0psf; h=30ft; Cat. II; Exp C; Enclosed; MWFRS (envelope) exterior zone and C-C Exterior(2E) 0-4-3 to 3-4-3, Interior (1) 3-4-3 to 8-1-4, Exterior(2R) 8-1-4 to 11-1-4, Interior (1) 11-1-4 to 15-10-5 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pg=20.0 psf; Pf=15.4 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 5) Unbalanced snow loads have been considered for this design. 6) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 15.4 psf on overhangs non-concurrent with other live loads. 7) Gable requires continuous bottom chord bearing. 8) Gable studs spaced at 4-0-0 oc. 9) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 6, 2, 6 except (jt=lb) 10=143, 8=143. 11) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 12) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building designer. LOAD CASE(S) Standard Job Truss Truss Type Qty Ply DWH - Woodside at West Clay Lot 29 P08 10 12004899-12T Piggyback Job Reference (optional) Run: 8.4 S 0 Apr 7 2020 Print: 8.400 S Apr 7 2020 MiTek Industries, Inc. Wed Jun 10 15:42:10 Page: 1 ID:K2HHL6dyoAiEZIFxXacWSezWxyH-eY_DKcb4mVeqmUJH9N9k9?zYRsBo2z31YeaqMjz7fHh 07/07/20 William Hohlt DE Job # 73384-W2 1 Dansco Engineering, LLC Date: 06/11/2020 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. 612 = 3x4 =4x4 =3x4 1 9 14 13 12 11 10 82 3 7 4 6 5 T1 T1 B1 ST3 ST2 ST1 ST2 ST1 Scale = 1:33.1 Loading (psf) Spacing 2-0-0 CSI DEFL in (loc) l/defl L/d PLATES GRIP TCLL (roof) 20.0 Plate Grip DOL 1.15 TC 0.08 Vert(LL) n/a - n/a 999 MT20 197/144 Snow (Pf/Pg) 15.4/20.0 Lumber DOL 1.15 BC 0.07 Vert(CT) n/a - n/a 999 TCDL 10.0 Rep Stress Incr YES WB 0.04 Horz(CT) 0.00 8 n/a n/a BCLL 0.0 Code IRC2018/TPI2014 Matrix-MSH BCDL 10.0 Weight: 49 lb FT = 20% LUMBER TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF Stud BRACING TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS All bearings 14-3-6. (lb) - Max Horiz 2=71 (LC 20), 15=71 (LC 20) Max Uplift All uplift 100 (lb) or less at joint(s) 2, 8, 11, 13, 15, 19 except 10=-103 (LC 17), 14=-104 (LC 16) Max Grav All reactions 250 (lb) or less at joint(s) 2, 8, 11, 12, 13, 15, 19 except 10=265 (LC 24), 14=265 (LC 23) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=5.0psf; BCDL=5.0psf; h=30ft; Cat. II; Exp C; Enclosed; MWFRS (envelope) exterior zone and C-C Exterior(2E) 0-4-3 to 3-4-3, Interior (1) 3-4-3 to 8-1-4, Exterior(2R) 8-1-4 to 11-1-4, Interior (1) 11-1-4 to 15-10-5 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pg=20.0 psf; Pf=15.4 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 5) Unbalanced snow loads have been considered for this design. 6) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 15.4 psf on overhangs non-concurrent with other live loads. 7) All plates are 1.5x4 MT20 unless otherwise indicated. 8) Gable requires continuous bottom chord bearing. 9) Gable studs spaced at 2-0-0 oc. 10) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 11) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 8, 13, 11, 2, 8 except (jt=lb) 14=103, 10=103. 12) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 13) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building designer. LOAD CASE(S) Standard Job Truss Truss Type Qty Ply DWH - Woodside at West Clay Lot 29 P09 1 12004899-12T Piggyback Job Reference (optional) Run: 8.4 S 0 Mar 10 2020 Print: 8.400 S Apr 7 2020 MiTek Industries, Inc. Wed Jun 10 15:42:11 Page: 1 ID:ZnJgEBkbhxrz8hRfZzGdJYzWxy8-6lYbXyciXomgNeuTi5hzhDVkwGXQnRmAnIJNu9z7fHg 07/07/20 William Hohlt DE Job # 73384-W2 1 Dansco Engineering, LLC Date: 06/11/2020 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. 6 12 =3x4 3x4 51 4 2 3 T1 W1 B1 Scale = 1:24.5 Loading (psf) Spacing 2-0-0 CSI DEFL in (loc) l/defl L/d PLATES GRIP TCLL (roof) 20.0 Plate Grip DOL 1.15 TC 0.03 Vert(LL) n/a - n/a 999 MT20 197/144 Snow (Pf/Pg) 15.4/20.0 Lumber DOL 1.15 BC 0.01 Vert(CT) n/a - n/a 999 TCDL 10.0 Rep Stress Incr YES WB 0.00 Horz(CT) n/a - n/a n/a BCLL 0.0 Code IRC2018/TPI2014 Matrix-MP BCDL 10.0 Weight: 5 lb FT = 20% LUMBER TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF Stud BRACING TOP CHORD Structural wood sheathing directly applied or 2-5-8 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS All bearings 1-2-7. (lb) - Max Horiz 2=45 (LC 15), 6=45 (LC 15) Max Uplift All uplift 100 (lb) or less at joint(s) 2, 4, 6 Max Grav All reactions 250 (lb) or less at joint(s) 2, 4, 6 FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=5.0psf; BCDL=5.0psf; h=30ft; Cat. II; Exp C; Enclosed; MWFRS (envelope) exterior zone and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pg=20.0 psf; Pf=15.4 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 4) Unbalanced snow loads have been considered for this design. 5) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 15.4 psf on overhangs non-concurrent with other live loads. 6) Gable requires continuous bottom chord bearing. 7) Gable studs spaced at 4-0-0 oc. 8) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 31 lb uplift at joint 2, 15 lb uplift at joint 4 and 31 lb uplift at joint 2. 10) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 11) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building designer. LOAD CASE(S) Standard Job Truss Truss Type Qty Ply DWH - Woodside at West Clay Lot 29 P10 4 12004899-12T Piggyback Job Reference (optional) Run: 8.4 S 0 Mar 10 2020 Print: 8.400 S Apr 7 2020 M iTek Industries, Inc. Wed Jun 10 15:42:11 Page: 1 ID:o0IeaK1P_0U28lmoau6oxPzWxq?-6lYbXyciXomgNeuTi5hzhDVliGYNnRNAnIJNu9z7fHg 07/07/20 William Hohlt DE Job # 73384-W2 1 Dansco Engineering, LLC Date: 06/11/2020 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. =6x6 11 10 9 8 7 6 1 5 2 4 3 T1 T2 W1 W8 B1 B2 W3 W4 W5 W6 W2 W7 Scale = 1:50 Loading (psf) Spacing 2-0-0 CSI DEFL in (loc) l/defl L/d PLATES GRIP TCLL (roof) 20.0 Plate Grip DOL 1.15 TC 0.43 Vert(LL) 0.12 9-11 >999 360 MT20 197/144 Snow (Pf/Pg) 15.4/20.0 Lumber DOL 1.15 BC 0.41 Vert(CT) -0.12 9-11 >999 240 TCDL 10.0 Rep Stress Incr YES WB 0.95 Horz(CT) 0.02 7 n/a n/a BCLL 0.0 Code IRC2018/TPI2014 Matrix-MSH BCDL 10.0 Weight: 109 lb FT = 20% LUMBER TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF Stud *Except* W4,W5:2x4 SPF No.2, W1:2x6 SPF No.2 BRACING TOP CHORD Structural wood sheathing directly applied or 5-8-7 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 7-3-1 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS (lb/size) 7=823/0-4-0, (min. 0-1-8), 11=749/ Mechanical, (min. 0-1-8) Max Horiz 11=265 (LC 15) Max Uplift 7=-188 (LC 17), 11=-159 (LC 16) Max Grav 7=934 (LC 2), 11=846 (LC 2) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-330/363, 2-12=-937/914, 12-13=-842/927, 3-13=-826/945, 3-14=-742/864, 14-15=-762/846, 4-15=-843/836, 4-5=-185/271, 1-11=-291/263, 5-7=-288/254 BOT CHORD 10-11=-592/742, 9-10=-592/742, 9-16=-311/500, 16-17=-311/500, 8-17=-311/500, 7-8=-490/645 WEBS 2-9=-310/293, 3-9=-555/423, 3-8=-473/317, 4-8=-225/257, 2-11=-733/500, 4-7=-817/572 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=5.0psf; BCDL=5.0psf; h=30ft; Cat. II; Exp C; Enclosed; MWFRS (envelope) exterior zone and C-C Exterior(2E) 0-2-12 to 3-2-12, Interior (1) 3-2-12 to 11-3-2, Exterior(2R) 11-3-2 to 14-3-2, Interior (1) 14-3-2 to 22-9-14 zone; cantilever right exposed ; end vertical right exposed; porch left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pg=20.0 psf; Pf=15.4 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 4) Unbalanced snow loads have been considered for this design. 5) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 15.4 psf on overhangs non-concurrent with other live loads. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) Refer to girder(s) for truss to truss connections. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 159 lb uplift at joint 11 and 188 lb uplift at joint 7. 9) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. LOAD CASE(S) Standard Job Truss Truss Type Qty Ply DWH - Woodside at West Clay Lot 29 T01 2 12004899-12T Common Job Reference (optional) Run: 8.4 S 0 Mar 10 2020 Print: 8.400 S Apr 7 2020 M iTek Industries, Inc. Wed Jun 10 15:42:11 Page: 1 ID:SrDpnU8xp0C0fzAiCuzf55zWnj1-6lYbXyciXomgNeuTi5hzhDVfRGS7nDYAnIJNu9z7fHg 07/07/20 William Hohlt DE Job # 73384-W2 1 Dansco Engineering, LLC Date: 06/11/2020 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. 17 15 14 13 12 11 101 9 2 3 8 7 4 65 T2 T1 T3 T2 T1 W1 W10 B1 B2 W5 W6 W5 W7 W8 W2 W9 W3 W4 Scale = 1:56.3 Plate Offsets (X, Y): [2:0-3-0,0-3-14], [5:0-3-12,0-1-12], [6:0-3-12,0-1-12], [9:0-2-12,0-1-8] Loading (psf) Spacing 2-0-0 CSI DEFL in (loc) l/defl L/d PLATES GRIP TCLL (roof) 20.0 Plate Grip DOL 1.15 TC 0.67 Vert(LL) 0.12 16-17 >705 360 MT18HS 197/144 Snow (Pf/Pg) 20.4/20.0 Lumber DOL 1.15 BC 0.36 Vert(CT) -0.13 16-17 >656 240 MT20 197/144 TCDL 10.0 Rep Stress Incr YES WB 0.34 Horz(CT) 0.01 11 n/a n/a BCLL 0.0 Code IRC2018/TPI2014 Matrix-MSH BCDL 10.0 Weight: 164 lb FT = 20% LUMBER TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 *Except* W8,W1,W10,W9:2x4 SPF Stud BRACING TOP CHORD Structural wood sheathing directly applied or 5-2-3 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 5-6. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. WEBS 1 Row at midpt 5-15, 6-15, 7-13, 4-16 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS (lb/size) 11=808/0-6-0, (min. 0-1-11), 16=997/0-6-0, (min. 0-2-3), 17=384/0-6-0, (min. 0-1-8) Max Horiz 17=-347 (LC 14) Max Uplift 11=-192 (LC 17), 16=-221 (LC 16), 17=-85 (LC 16) Max Grav 11=1061 (LC 41), 16=1402 (LC 41), 17=469 (LC 41) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 4-21=-570/208, 5-21=-398/230, 5-6=-316/203, 6-22=-545/230, 22-23=-612/214, 23-24=-698/197, 7-24=-816/196, 7-8=-939/199, 8-25=-1085/179, 25-26=-1093/178, 9-26=-1188/172, 2-17=-403/162, 9-11=-1001/219 BOT CHORD 17-27=-340/354, 16-27=-340/354, 14-15=-47/482, 13-14=-47/482, 12-13=-36/868 WEBS 6-15=-485/149, 6-13=-139/489, 7-13=-557/276, 9-12=0/718, 4-16=-1250/234, 4-15=-45/506 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=5.0psf; BCDL=5.0psf; h=30ft; Cat. II; Exp C; Enclosed; MWFRS (envelope) exterior zone and C-C Exterior(2E) -1-6-12 to 1-5-4, Interior (1) 1-5-4 to 12-2-5, Exterior(2E) 12-2-5 to 15-11-11, Exterior(2R) 15-11-11 to 20-2-9, Interior (1) 20-2-9 to 29-8-12 zone; cantilever left and right exposed ; end vertical left and right exposed; porch left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pg=20.0 psf; Pf=20.4 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10, Lu=50-0-0; Min. flat roof snow load governs. Rain surcharge applied to all exposed surfaces with slopes less than 0.500/12 in accordance with IBC 1608.3.4. 4) Unbalanced snow loads have been considered for this design. 5) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 15.4 psf on overhangs non-concurrent with other live loads. 6) Provide adequate drainage to prevent water ponding. 7) All plates are MT20 plates unless otherwise indicated. 8) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 85 lb uplift at joint 17, 221 lb uplift at joint 16 and 192 lb uplift at joint 11. 10) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 11) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. LOAD CASE(S) Standard Job Truss Truss Type Qty Ply DWH - Woodside at West Clay Lot 29 T02 3 12004899-12T Piggyback Base Job Reference (optional) Run: 8.4 S 0 Mar 10 2020 Print: 8.400 S Apr 7 2020 M iTek Industries, Inc. Wed Jun 10 15:42:12 Page: 1 ID:gpqnJWudURpSSmxM oeEMEFzWnJX-ax6zlIdKI6vX?oTfGoCCEQ2lRfp7WoJJ?y3xRcz7fHf 07/07/20 William Hohlt DE Job # 73384-W2 1 Dansco Engineering, LLC Date: 06/11/2020 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. 15 13 12 11 10 9 8 7 1 6 5 2 3 4 T1 T2 T3 T4 W1 W10 B1 B2 W5 W6 W5 W7 W8 W2 W9 W3 W4 Scale = 1:56.3 Plate Offsets (X, Y): [1:Edge,0-1-8], [3:0-3-12,0-1-12], [4:0-3-12,0-1-12], [7:0-2-12,0-1-8] Loading (psf) Spacing 2-0-0 CSI DEFL in (loc) l/defl L/d PLATES GRIP TCLL (roof) 20.0 Plate Grip DOL 1.15 TC 0.77 Vert(LL) 0.13 14-15 >682 360 MT20 197/144 Snow (Pf/Pg) 20.4/20.0 Lumber DOL 1.15 BC 0.36 Vert(CT) -0.13 14-15 >661 240 TCDL 10.0 Rep Stress Incr YES WB 0.34 Horz(CT) 0.01 9 n/a n/a BCLL 0.0 Code IRC2018/TPI2014 Matrix-MSH BCDL 10.0 Weight: 161 lb FT = 20% LUMBER TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 *Except* W8,W1,W10,W9:2x4 SPF Stud BRACING TOP CHORD Structural wood sheathing directly applied or 5-2-1 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 3-4. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 3-13, 4-13, 5-11, 2-14 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS (lb/size) 9=810/0-6-0, (min. 0-1-11), 14=1004/0-6-0, (min. 0-2-3), 15=262/0-6-0, (min. 0-1-8) Max Horiz 15=-331 (LC 14) Max Uplift 9=-190 (LC 17), 14=-226 (LC 16), 15=-60 (LC 12) Max Grav 9=1063 (LC 41), 14=1413 (LC 41), 15=344 (LC 41) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-19=-580/208, 3-19=-401/229, 3-4=-318/201, 4-20=-547/228, 20-21=-614/212, 21-22=-700/196, 5-22=-818/194, 5-6=-942/197, 6-23=-1087/177, 23-24=-1096/176, 7-24=-1190/170, 1-15=-279/69, 7-9=-1002/218 BOT CHORD 15-25=-310/342, 14-25=-310/342, 12-13=-45/484, 11-12=-45/484, 10-11=-35/870 WEBS 4-13=-485/151, 4-11=-139/489, 5-11=-557/276, 7-10=0/719, 2-14=-1266/254, 2-13=-46/489 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=5.0psf; BCDL=5.0psf; h=30ft; Cat. II; Exp C; Enclosed; MWFRS (envelope) exterior zone and C-C Exterior(2E) 0-7-12 to 3-7-12, Interior (1) 3-7-12 to 12-2-5, Exterior(2E) 12-2-5 to 15-11-11, Exterior(2R) 15-11-11 to 20-2-9, Interior (1) 20-2-9 to 29-8-12 zone; cantilever left and right exposed ; end vertical left and right exposed; porch left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pg=20.0 psf; Pf=20.4 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10, Lu=50-0-0; Min. flat roof snow load governs. Rain surcharge applied to all exposed surfaces with slopes less than 0.500/12 in accordance with IBC 1608.3.4. 4) Unbalanced snow loads have been considered for this design. 5) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 15.4 psf on overhangs non-concurrent with other live loads. 6) Provide adequate drainage to prevent water ponding. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 60 lb uplift at joint 15, 226 lb uplift at joint 14 and 190 lb uplift at joint 9. 9) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 10) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. LOAD CASE(S) Standard Job Truss Truss Type Qty Ply DWH - Woodside at West Clay Lot 29 T03 3 12004899-12T Piggyback Base Job Reference (optional) Run: 8.4 S 0 Mar 10 2020 Print: 8.400 S Apr 7 2020 M iTek Industries, Inc. Wed Jun 10 15:42:12 Page: 1 ID:gdP30yVdT6FD4cK9IrfKo0zW nIk-ax6zlIdKI6vX?oTfGoCCEQ2jufp7WoJJ?y3xRcz7fHf 07/07/20 William Hohlt DE Job # 73384-W2 1 Dansco Engineering, LLC Date: 06/11/2020 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. 15 14 13 12 11 10 9 8 7 1 6 52 43 T1 T2 T3 T4 W1 W10 B1 B2 W3 W4 W5 W6 W5 W7 W8 W2 W9 Scale = 1:56.3 Plate Offsets (X, Y): [1:0-1-4,0-1-12], [3:0-3-12,0-1-12], [4:0-3-12,0-1-12], [7:0-2-12,0-1-8] Loading (psf) Spacing 2-0-0 CSI DEFL in (loc) l/defl L/d PLATES GRIP TCLL (roof) 20.0 Plate Grip DOL 1.15 TC 0.68 Vert(LL) -0.05 10-11 >999 360 MT20 197/144 Snow (Pf/Pg) 20.4/20.0 Lumber DOL 1.15 BC 0.40 Vert(CT) -0.10 10-11 >999 240 TCDL 10.0 Rep Stress Incr YES WB 0.48 Horz(CT) 0.03 9 n/a n/a BCLL 0.0 Code IRC2018/TPI2014 Matrix-MSH BCDL 10.0 Weight: 158 lb FT = 20% LUMBER TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF Stud *Except* W4,W5,W6,W7:2x4 SPF No.2 BRACING TOP CHORD Structural wood sheathing directly applied or 3-11-15 oc purlins, except end verticals, and 2-0-0 oc purlins (5-10-5 max.): 3-4. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 2-13, 3-11, 5-11 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS (lb/size) 9=1065/0-6-0, (min. 0-2-4), 15=1011/0-6-0, (min. 0-2-3) Max Horiz 15=-331 (LC 12) Max Uplift 9=-228 (LC 17), 15=-192 (LC 16) Max Grav 9=1421 (LC 41), 15=1399 (LC 41) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-16=-1460/188, 16-17=-1370/190, 2-17=-1223/210, 2-18=-1311/250, 18-19=-1277/254, 19-20=-1116/271, 3-20=-1059/286, 3-4=-909/299, 4-21=-1079/289, 21-22=-1146/273, 22-23=-1232/257, 5-23=-1350/255, 5-6=-1424/248, 6-24=-1568/228, 24-25=-1578/227, 7-25=-1672/221, 1-15=-1346/214, 7-9=-1359/255 BOT CHORD 14-15=-286/333, 13-14=-187/1098, 12-13=-102/886, 11-12=-102/886, 10-11=-76/1255 WEBS 2-14=-254/94, 2-13=-366/232, 3-13=-123/360, 4-11=-102/374, 5-11=-514/270, 1-14=-84/1109, 7-10=-32/1100 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=5.0psf; BCDL=5.0psf; h=30ft; Cat. II; Exp C; Enclosed; MWFRS (envelope) exterior zone and C-C Exterior(2E) 0-7-12 to 3-7-12, Interior (1) 3-7-12 to 12-2-5, Exterior(2E) 12-2-5 to 15-11-11, Exterior(2R) 15-11-11 to 20-2-9, Interior (1) 20-2-9 to 29-8-12 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pg=20.0 psf; Pf=20.4 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10, Lu=50-0-0; Min. flat roof snow load governs. Rain surcharge applied to all exposed surfaces with slopes less than 0.500/12 in accordance with IBC 1608.3.4. 4) Unbalanced snow loads have been considered for this design. 5) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 15.4 psf on overhangs non-concurrent with other live loads. 6) Provide adequate drainage to prevent water ponding. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 192 lb uplift at joint 15 and 228 lb uplift at joint 9. 9) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 10) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. LOAD CASE(S) Standard Job Truss Truss Type Qty Ply DWH - Woodside at West Clay Lot 29 T04 5 12004899-12T Piggyback Base Job Reference (optional) Run: 8.4 S 0 Mar 10 2020 Print: 8.400 S Apr 7 2020 M iTek Industries, Inc. Wed Jun 10 15:42:13 Page: 1 ID:vMSSv1cGLtNxf_WuJEJRgvzWnIb-27fMyeez3Q1Ody2rqWjRnebw137kFDNTEcoUz2z7fHe 07/07/20 William Hohlt DE Job # 73384-W2 1 Dansco Engineering, LLC Date: 06/11/2020 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. 3x4 19 18 15 14 13 12 11 10 916 17 8 1 2 7 6 3 4 5 T1 T2 T3 T4 W1 W14 B1 B3 B5 B2 B3 B4 W5 W8 W7 W9 W10 W9 W11 W12 W13W3 W2 W4 W6 Scale = 1:61.4 Plate Offsets (X, Y): [2:0-1-0,0-2-0], [4:0-7-8,0-1-8], [5:0-3-12,0-1-12], [8:0-2-12,0-1-8], [16:0-2-12,0-2-4] Loading (psf) Spacing 2-0-0 CSI DEFL in (loc) l/defl L/d PLATES GRIP TCLL (roof) 20.0 Plate Grip DOL 1.15 TC 0.67 Vert(LL) -0.06 3 >999 360 MT20 197/144 Snow (Pf/Pg) 20.4/20.0 Lumber DOL 1.15 BC 0.40 Vert(CT) -0.11 11-12 >999 240 TCDL 10.0 Rep Stress Incr YES WB 0.62 Horz(CT) 0.06 10 n/a n/a BCLL 0.0 Code IRC2018/TPI2014 Matrix-MSH BCDL 10.0 Weight: 182 lb FT = 20% LUMBER TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 *Except* B2:2x4 SPF Stud WEBS 2x4 SPF Stud *Except* W7,W9,W10,W11:2x4 SPF No.2 BRACING TOP CHORD Structural wood sheathing directly applied or 4-0-3 oc purlins, except end verticals, and 2-0-0 oc purlins (5-10-10 max.): 4-5. BOT CHORD Rigid ceiling directly applied or 9-9-2 oc bracing. WEBS 1 Row at midpt 4-14, 4-12, 6-12 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS (lb/size) 10=1064/0-6-0, (min. 0-2-4), 19=1009/0-6-0, (min. 0-2-3) Max Horiz 19=-331 (LC 12) Max Uplift 10=-228 (LC 17), 19=-193 (LC 16) Max Grav 10=1421 (LC 41), 19=1400 (LC 41) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-1307/231, 2-20=-1681/241, 20-21=-1536/253, 3-21=-1411/269, 3-22=-1669/464, 4-22=-1502/475, 4-5=-909/300, 5-23=-1078/291, 23-24=-1146/275, 24-25=-1231/259, 6-25=-1349/257, 6-7=-1423/248, 7-26=-1568/228, 26-27=-1577/227, 8-27=-1672/221, 1-19=-1343/241, 8-10=-1358/255 BOT CHORD 2-17=-491/163, 16-17=-363/1308, 3-16=-501/299, 13-14=-102/880, 12-13=-102/880, 11-12=-76/1254 WEBS 14-16=-86/778, 4-16=-342/850, 5-12=-94/359, 6-12=-514/270, 8-11=-32/1099, 17-19=-340/340, 1-17=-202/1170 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=5.0psf; BCDL=5.0psf; h=30ft; Cat. II; Exp C; Enclosed; MWFRS (envelope) exterior zone and C-C Exterior(2E) 0-7-12 to 3-7-12, Interior (1) 3-7-12 to 12-2-5, Exterior(2E) 12-2-5 to 15-11-11, Exterior(2R) 15-11-11 to 20-2-9, Interior (1) 20-2-9 to 29-8-12 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pg=20.0 psf; Pf=20.4 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10, Lu=50-0-0; Min. flat roof snow load governs. Rain surcharge applied to all exposed surfaces with slopes less than 0.500/12 in accordance with IBC 1608.3.4. 4) Unbalanced snow loads have been considered for this design. 5) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 15.4 psf on overhangs non-concurrent with other live loads. 6) Provide adequate drainage to prevent water ponding. 7) All plates are 3x4 MT20 unless otherwise indicated. 8) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 228 lb uplift at joint 10 and 193 lb uplift at joint 19. 10) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 11) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. LOAD CASE(S) Standard Job Truss Truss Type Qty Ply DWH - Woodside at West Clay Lot 29 T05 6 12004899-12T Piggyback Base Job Reference (optional) Run: 8.4 S 0 Apr 7 2020 Print: 8.400 S Apr 7 2020 MiTek Industries, Inc. Wed Jun 10 15:42:13 Page: 1 ID:V2Ilrqn22B8yK8ba8AZjEszW nIN-27fMyeez3Q1Ody2rqWjRnebw837hFBDTEcoUz2z7fHe 07/07/20 William Hohlt DE Job # 73384-W2 1 Dansco Engineering, LLC Date: 06/11/2020 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. 612 =6x6 20 19 17 13 12 11 1 15 2 14 16 3 5 6 7 8 9 104 T1 T2 T3 W12 W1 B1 B2 B3 B2 B4 W3 W4 W5 W7 W6 W9 W8 W9 W11 W10 W12 W13 W2 W8 W8 0-1-14 Scale = 1:66 Plate Offsets (X, Y): [2:0-2-15,0-2-0], [14:0-2-8,0-2-12], [16:0-2-4,0-2-4] Loading (psf) Spacing 2-0-0 CSI DEFL in (loc) l/defl L/d PLATES GRIP TCLL (roof) 20.0 Plate Grip DOL 1.15 TC 0.52 Vert(LL) -0.08 14-15 >999 360 MT20 197/144 Snow (Pf/Pg) 20.4/20.0 Lumber DOL 1.15 BC 0.42 Vert(CT) -0.15 14-15 >999 240 TCDL 10.0 Rep Stress Incr YES WB 0.68 Horz(CT) 0.04 11 n/a n/a BCLL 0.0 Code IRC2018/TPI2014 Matrix-MSH BCDL 10.0 Weight: 195 lb FT = 20% LUMBER TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 *Except* B2:2x4 SPF Stud WEBS 2x4 SPF Stud *Except* W9,W13:2x4 SPF No.2 BRACING TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (4-9-4 max.): 4-10. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. WEBS 1 Row at midpt 10-11, 4-18 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS (lb/size) 11=863/ Mechanical, (min. 0-1-8), 18=1931/0-6-0, (min. 0-3-9), 20=20/0-4-0, (min. 0-1-8) Max Horiz 20=219 (LC 16) Max Uplift 11=-241 (LC 12), 18=-607 (LC 13), 20=-220 (LC 45) Max Grav 11=1134 (LC 37), 18=2257 (LC 37), 20=378 (LC 38) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-21=-172/572, 3-21=-130/609, 3-4=-237/945, 4-5=-113/412, 5-22=-867/184, 22-23=-867/184, 6-23=-867/184, 6-24=-867/184, 24-25=-867/184, 7-25=-867/184, 7-8=-1277/282, 8-9=-1277/282, 9-26=-837/178, 10-26=-837/178, 10-11=-1083/262, 2-20=-330/264 BOT CHORD 20-27=-283/136, 19-27=-283/136, 18-19=-511/87, 5-16=-1357/351, 15-16=-321/101, 14-15=-291/1304 WEBS 3-19=-302/261, 3-18=-608/505, 4-18=-1444/346, 16-18=-955/213, 4-16=-212/988, 5-15=-326/1540, 6-15=-512/196, 7-15=-565/137, 12-14=-170/780, 9-14=-133/565, 9-12=-916/288, 10-12=-254/1199, 2-19=-545/178 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=5.0psf; BCDL=5.0psf; h=30ft; Cat. II; Exp C; Enclosed; MWFRS (envelope) exterior zone and C-C Exterior(2E) -1-2-12 to 2-3-14, Interior (1) 2-3-14 to 10-2-8, Exterior(2R) 10-2-8 to 15-2-12, Interior (1) 15-2-12 to 35-4-4 zone; cantilever left exposed ; end vertical left exposed; porch left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pg=20.0 psf; Pf=20.4 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10, Lu=50-0-0; Min. flat roof snow load governs. Rain surcharge applied to all exposed surfaces with slopes less than 0.500/12 in accordance with IBC 1608.3.4. 4) Unbalanced snow loads have been considered for this design. 5) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 15.4 psf on overhangs non-concurrent with other live loads. 6) Provide adequate drainage to prevent water ponding. 7) All plates are 3x4 MT20 unless otherwise indicated. 8) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 9) Refer to girder(s) for truss to truss connections. 10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 241 lb uplift at joint 11, 220 lb uplift at joint 20 and 607 lb uplift at joint 18. 11) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 12) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. LOAD CASE(S) Standard Job Truss Truss Type Qty Ply DWH - Woodside at West Clay Lot 29 T06 1 12004899-12T Half Hip Job Reference (optional) Run: 8.4 S 0 Apr 7 2020 Print: 8.400 S Apr 7 2020 MiTek Industries, Inc. Wed Jun 10 15:42:14 Page: 1 ID:9iXfwqw?6evughA1v0u7R8zX6i3-XKDk9_ebqj9FE6d2ODEgJr77GTTg_dZcTGY1VUz7fHd 07/07/20 William Hohlt DE Job # 73384-W2 1 Dansco Engineering, LLC Date: 06/11/2020 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. 612 23 22 20 15 14 13 1 19 18 17 16 2 3 4 5 6 8 9 10 11 127 T2 T1 T3 T4 W15 W1 B1 B5 B2 B3 B4 W7 W12 W14 W13 W15 W16 W5 W6 W3 W4 W2 W11W9 W10 W11 W8 Scale = 1:66 Plate Offsets (X, Y): [2:0-2-15,0-2-0], [7:0-6-0,0-0-15], [16:0-3-0,0-2-8], [19:0-2-8,0-2-8] Loading (psf) Spacing 2-0-0 CSI DEFL in (loc) l/defl L/d PLATES GRIP TCLL (roof) 20.0 Plate Grip DOL 1.15 TC 0.51 Vert(LL) -0.07 16-17 >999 360 MT20 197/144 Snow (Pf/Pg) 20.4/20.0 Lumber DOL 1.15 BC 0.33 Vert(CT) -0.12 16-17 >999 240 TCDL 10.0 Rep Stress Incr YES WB 1.00 Horz(CT) 0.04 13 n/a n/a BCLL 0.0 Code IRC2018/TPI2014 Matrix-MSH BCDL 10.0 Weight: 219 lb FT = 20% LUMBER TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 *Except* B2:2x4 SPF Stud WEBS 2x4 SPF Stud *Except* W15,W12,W13,W16,W10:2x4 SPF No.2 BRACING TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (5-0-15 max.): 7-12. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. WEBS 1 Row at midpt 12-13 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS (lb/size) 13=924/ Mechanical, (min. 0-1-8), 21=1666/0-6-0, (min. 0-2-14), 23=190/0-4-0, (min. 0-1-8) Max Horiz 23=282 (LC 16) Max Uplift 13=-262 (LC 13), 21=-504 (LC 13), 23=-42 (LC 16) Max Grav 13=1235 (LC 37), 21=1815 (LC 37), 23=370 (LC 38) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-24=-254/199, 4-26=-213/468, 26-27=-201/496, 5-27=-199/527, 7-28=-940/206, 8-28=-941/205, 8-29=-1136/245, 9-29=-1136/245, 9-10=-1129/246, 10-11=-1129/246, 11-30=-745/157, 12-30=-745/157, 12-13=-1185/283, 2-23=-324/206 BOT CHORD 23-31=-327/160, 22-31=-327/160, 22-32=-305/165, 21-32=-305/165, 16-17=-204/938, 9-16=-455/169 WEBS 19-21=-448/77, 8-16=-68/305, 14-16=-146/652, 11-16=-131/570, 11-14=-968/298, 12-14=-257/1218, 5-21=-1337/330, 5-19=-210/1094, 4-22=-286/223, 4-21=-550/463, 7-17=-249/1181, 8-17=-768/249, 7-19=-1182/230 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=5.0psf; BCDL=5.0psf; h=30ft; Cat. II; Exp C; Enclosed; MWFRS (envelope) exterior zone and C-C Exterior(2E) -1-2-12 to 2-3-14, Interior (1) 2-3-14 to 13-2-8, Exterior(2R) 13-2-8 to 18-2-12, Interior (1) 18-2-12 to 35-4-4 zone; cantilever left exposed ; end vertical left exposed; porch left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pg=20.0 psf; Pf=20.4 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10, Lu=50-0-0; Min. flat roof snow load governs. Rain surcharge applied to all exposed surfaces with slopes less than 0.500/12 in accordance with IBC 1608.3.4. 4) Unbalanced snow loads have been considered for this design. 5) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 15.4 psf on overhangs non-concurrent with other live loads. 6) Provide adequate drainage to prevent water ponding. 7) All plates are 3x4 MT20 unless otherwise indicated. 8) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 9) Refer to girder(s) for truss to truss connections. 10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 262 lb uplift at joint 13, 42 lb uplift at joint 23 and 504 lb uplift at joint 21. 11) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 12) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. LOAD CASE(S) Standard Job Truss Truss Type Qty Ply DWH - Woodside at West Clay Lot 29 T07 1 12004899-12T Half Hip Job Reference (optional) Run: 8.4 S 0 Apr 7 2020 Print: 8.400 S Apr 7 2020 MiTek Industries, Inc. Wed Jun 10 15:42:14 Page: 1 ID:ZHDnZryuPZHSX8vca8Rq2mzX6i0-XKDk9_ebqj9FE6d2ODEgJr78TTU?_YQcTGY1VUz7fHd 07/07/20 William Hohlt DE Job # 73384-W2 1 Dansco Engineering, LLC Date: 06/11/2020 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. 612 24 23 21 15 14 13 1 19 18 17 16 2 20 3 4 5 6 7 8 9 10 11 12 T2 T1 T3 T4 T5 W18 W1 B1 B2 B3 B4 B5 W7 W9 W10 W11W12 W13 W14 W15 W17 W16 W18 W19 W5 W6 W2 W3 W4 W8 W14 ST6 ST5 ST4 ST3ST2 ST1 Scale = 1:66.2 Plate Offsets (X, Y): [2:0-2-15,0-2-0], [6:0-1-12,0-2-0], [8:0-3-12,Edge], [9:0-6-0,0-2-8], [16:0-3-0,0-2-8] Loading (psf) Spacing 2-0-0 CSI DEFL in (loc) l/defl L/d PLATES GRIP TCLL (roof) 20.0 Plate Grip DOL 1.15 TC 0.67 Vert(LL) 0.03 23-24 >999 360 MT20 197/144 Snow (Pf/Pg) 20.4/20.0 Lumber DOL 1.15 BC 0.25 Vert(CT) -0.08 13-14 >999 240 TCDL 10.0 Rep Stress Incr YES WB 0.96 Horz(CT) 0.02 13 n/a n/a BCLL 0.0 Code IRC2018/TPI2014 Matrix-MSH BCDL 10.0 Weight: 311 lb FT = 20% LUMBER TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 *Except* B2:2x4 SPF Stud WEBS 2x4 SPF No.2 *Except* W7,W9,W17,W1,W5,W6,W2,W3,W4,W8:2x4 SPF Stud OTHERS 2x4 SPF Stud *Except* ST3,ST2:2x4 SPF No.2 BRACING TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 7-8, 9-12. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing, Except: 6-0-0 oc bracing: 23-24,22-23,20-21. 1 Row at midpt 10-16 WEBS 1 Row at midpt 12-13, 8-19, 8-17, 9-17, 9-16, 11-14 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS (lb/size) 13=919/ Mechanical, (min. 0-1-8), 22=1578/0-6-0, (min. 0-2-14), 24=222/0-4-0, (min. 0-1-8) Max Horiz 24=419 (LC 16) Max Uplift 13=-250 (LC 13), 22=-465 (LC 16), 24=-16 (LC 12) Max Grav 13=1160 (LC 43), 22=1835 (LC 44), 24=277 (LC 44) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 4-39=-308/427, 5-39=-285/444, 6-40=-477/57, 40-41=-468/67, 7-41=-434/74, 7-8=-394/97, 8-9=-692/145, 9-10=-653/152, 10-42=-656/153, 42-43=-656/153, 43-44=-656/153, 11-44=-656/153, 11-45=-498/108, 12-45=-498/108, 12-13=-1107/273 BOT CHORD 24-46=-460/212, 23-46=-460/212, 22-23=-369/91, 6-20=-912/285, 18-19=-176/540, 17-18=-175/541, 16-17=-161/594, 10-16=-343/128 WEBS 20-22=-413/43, 6-19=-142/720, 8-19=-605/104, 14-16=-106/433, 11-16=-115/322, 11-14=-841/279, 12-14=-219/1010, 5-22=-1273/387, 5-20=-216/818, 4-23=-299/219, 4-22=-485/476 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=5.0psf; BCDL=5.0psf; h=30ft; Cat. II; Exp C; Enclosed; MWFRS (envelope) exterior zone and C-C Exterior(2E) -1-2-12 to 2-3-14, Interior (1) 2-3-14 to 16-2-8, Exterior(2E) 16-2-8 to 18-0-8, Interior (1) 18-0-8 to 21-3-0, Exterior(2R) 21-3-0 to 24-9-10, Interior (1) 24-9-10 to 35-4-4 zone; cantilever left exposed ; end vertical left exposed; porch left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pg=20.0 psf; Pf=20.4 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10, Lu=50-0-0; Min. flat roof snow load governs. Rain surcharge applied to all exposed surfaces with slopes less than 0.500/12 in accordance with IBC 1608.3.4. 5) Unbalanced snow loads have been considered for this design. 6) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 15.4 psf on overhangs non-concurrent with other live loads. 7) Provide adequate drainage to prevent water ponding. 8) All plates are 3x4 MT20 unless otherwise indicated. 9) Gable studs spaced at 2-0-0 oc. 10) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 11) Refer to girder(s) for truss to truss connections. 12) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 250 lb uplift at joint 13, 16 lb uplift at joint 24 and 465 lb uplift at joint 22. Job Truss Truss Type Qty Ply DWH - Woodside at West Clay Lot 29 T08 1 12004899-12T Piggyback Base Structural Gable Job Reference (optional) Run: 8.4 S 0 Apr 7 2020 Print: 8.400 S Apr 7 2020 MiTek Industries, Inc. Wed Jun 10 15:42:15 Page: 1 ID:sd8R1F1HljATtDxyV63TqFzX6hv-?W n6NKfDa1H6sGBExxlvs3gGktsXj0QmhwHb1w z7fHc Continued on page 2 07/07/20 William Hohlt DE Job # 73384-W2 1 Dansco Engineering, LLC Date: 06/11/2020 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. 13) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 14) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. LOAD CASE(S) Standard Job Truss Truss Type Qty Ply DWH - Woodside at West Clay Lot 29 T08 1 12004899-12T Piggyback Base Structural Gable Job Reference (optional) Run: 8.4 S 0 Apr 7 2020 Print: 8.400 S Apr 7 2020 MiTek Industries, Inc. Wed Jun 10 15:42:15 Page: 2 ID:sd8R1F1HljATtDxyV63TqFzX6hv-?Wn6NKfDa1H6sGBExxlvs3gGktsXj0QmhwHb1wz7fHc 07/07/20 William Hohlt DE Job # 73384-W2 1 Dansco Engineering, LLC Date: 06/11/2020 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. 22 21 19 14 13 12 1 17 16 15 2 18 3 4 5 6 87 9 10 11 T2 T1 T3 T4 T5 W16 W1 B1 B5 B2 B3 B4 W7 W9 W10 W13 W15 W14 W16 W17 W5 W6 W2 W3 W4 W12 W11 W8 W12 0-1-14 Scale = 1:67.3 Plate Offsets (X, Y): [2:0-2-15,0-2-0], [6:0-3-0,0-2-0], [8:0-2-12,0-4-0], [15:0-3-0,0-2-8] Loading (psf) Spacing 2-0-0 CSI DEFL in (loc) l/defl L/d PLATES GRIP TCLL (roof) 20.0 Plate Grip DOL 1.15 TC 0.68 Vert(LL) -0.06 17-18 >999 360 MT20 197/144 Snow (Pf/Pg) 20.4/20.0 Lumber DOL 1.15 BC 0.43 Vert(CT) -0.13 17-18 >999 240 TCDL 10.0 Rep Stress Incr YES WB 0.93 Horz(CT) 0.02 12 n/a n/a BCLL 0.0 Code IRC2018/TPI2014 Matrix-MSH BCDL 10.0 Weight: 267 lb FT = 20% LUMBER TOP CHORD 2x4 SPF No.2 *Except* T3:2x6 SPF No.2, T4:2x8 SP 2400F 2.0E BOT CHORD 2x4 SPF No.2 *Except* B2:2x4 SPF Stud WEBS 2x4 SPF No.2 *Except* W7,W15,W1,W5,W6,W2,W3,W4,W8:2x4 SPF Stud BRACING TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 7-11. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. Except: 1 Row at midpt 9-15 WEBS 1 Row at midpt 11-12, 7-17, 8-15, 10-13, 8-17 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS (lb/size) 12=924/ Mechanical, (min. 0-1-8), 20=1570/0-6-0, (min. 0-2-12), 22=227/0-4-0, (min. 0-1-8) Max Horiz 22=416 (LC 16) Max Uplift 12=-264 (LC 13), 20=-431 (LC 16), 22=-11 (LC 12) Max Grav 12=1178 (LC 37), 20=1739 (LC 38), 22=275 (LC 2) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 3-4=-278/340, 4-24=-267/364, 5-24=-266/427, 6-25=-651/86, 25-26=-645/89, 7-26=-602/116, 7-8=-541/133, 8-9=-696/158, 9-27=-702/165, 10-27=-689/166, 10-28=-489/111, 11-28=-489/111, 11-12=-1129/285 BOT CHORD 22-29=-431/211, 21-29=-431/211, 20-21=-364/73, 6-18=-917/282, 16-17=-158/622, 15-16=-157/622, 9-15=-410/149 WEBS 18-20=-413/62, 6-17=-103/681, 13-15=-108/419, 10-15=-113/402, 10-13=-872/295, 11-13=-236/1039, 5-20=-1236/348, 5-18=-191/863, 3-21=-294/217, 3-20=-433/474, 8-17=-401/126 NOTES 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=5.0psf; BCDL=5.0psf; h=30ft; Cat. II; Exp C; Enclosed; MWFRS (envelope) exterior zone and C-C Exterior(2E) -1-2-12 to 2-3-14, Interior (1) 2-3-14 to 19-2-8, Exterior(2R) 19-2-8 to 24-3-12, Interior (1) 24-3-12 to 35-4-4 zone; cantilever left exposed ; end vertical left exposed; porch left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pg=20.0 psf; Pf=20.4 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10, Lu=50-0-0; Min. flat roof snow load governs. Rain surcharge applied to all exposed surfaces with slopes less than 0.500/12 in accordance with IBC 1608.3.4. 3) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 15.4 psf on overhangs non-concurrent with other live loads. 5) Provide adequate drainage to prevent water ponding. 6) All plates are 3x4 MT20 unless otherwise indicated. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) Refer to girder(s) for truss to truss connections. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 264 lb uplift at joint 12, 11 lb uplift at joint 22 and 431 lb uplift at joint 20. 10) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 11) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. LOAD CASE(S) Standard Job Truss Truss Type Qty Ply DWH - Woodside at West Clay Lot 29 T09 1 12004899-12T Piggyback Base Job Reference (optional) Run: 8.4 S 0 Apr 7 2020 Print: 8.400 S Apr 7 2020 MiTek Industries, Inc. Wed Jun 10 15:42:16 Page: 1 ID:9_34Ve7g6s2TDIzIP4h6djzX6ho-TiLUaggrLLPzUPmQVeG8OGCRLH90ST6vwa18aNz7fHb 07/07/20 William Hohlt DE Job # 73384-W2 1 Dansco Engineering, LLC Date: 06/11/2020 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. 21 20 18 14 13 12 1 16 15 2 17 3 4 5 6 7 8 9 10 11 T2 T1 T3 T4 W15 W1 B1 B5 B2 B3 B4 W7 W9 W10 W11 W14 W13 W15 W16 W5 W6 W2 W3 W4 W8 W12 Scale = 1:63.2 Plate Offsets (X, Y): [2:0-2-15,0-2-0], [6:0-2-12,0-2-0], [7:0-4-0,0-2-8], [15:0-3-0,0-2-8] Loading (psf) Spacing 2-0-0 CSI DEFL in (loc) l/defl L/d PLATES GRIP TCLL (roof) 20.0 Plate Grip DOL 1.15 TC 0.77 Vert(LL) -0.07 16-17 >999 360 MT20 197/144 Snow (Pf/Pg) 20.4/20.0 Lumber DOL 1.15 BC 0.47 Vert(CT) -0.14 16-17 >999 240 TCDL 10.0 Rep Stress Incr YES WB 0.93 Horz(CT) 0.02 12 n/a n/a BCLL 0.0 Code IRC2018/TPI2014 Matrix-MSH BCDL 10.0 Weight: 241 lb FT = 20% LUMBER TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 *Except* B2:2x4 SPF Stud WEBS 2x4 SPF Stud *Except* W15,W9,W10,W11,W13,W16,W12:2x4 SPF No.2 BRACING TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 7-11. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. Except: 1 Row at midpt 8-15 WEBS 1 Row at midpt 11-12, 7-16, 7-15, 9-13 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS (lb/size) 12=925/ Mechanical, (min. 0-1-8), 19=1562/0-6-0, (min. 0-2-12), 21=231/0-4-0, (min. 0-1-8) Max Horiz 21=434 (LC 16) Max Uplift 12=-263 (LC 13), 19=-436 (LC 16), 21=-17 (LC 12) Max Grav 12=1178 (LC 37), 19=1744 (LC 38), 21=279 (LC 2) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 3-4=-276/322, 4-23=-265/354, 5-23=-264/419, 6-24=-661/90, 24-25=-650/93, 7-25=-607/122, 7-8=-685/165, 8-26=-684/166, 9-26=-684/166, 9-27=-488/110, 10-27=-488/110, 10-11=-488/110, 11-12=-1128/284 BOT CHORD 21-28=-441/200, 20-28=-441/200, 19-20=-363/73, 6-17=-927/286, 15-16=-139/547, 8-15=-460/172 WEBS 17-19=-409/60, 6-16=-95/657, 7-16=-292/132, 7-15=-97/313, 13-15=-107/413, 9-15=-107/382, 9-13=-870/294, 11-13=-234/1037, 5-19=-1236/349, 5-17=-198/881, 3-20=-295/217, 3-19=-432/473 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=5.0psf; BCDL=5.0psf; h=30ft; Cat. II; Exp C; Enclosed; MWFRS (envelope) exterior zone and C-C Exterior(2E) -1-2-12 to 2-3-14, Interior (1) 2-3-14 to 19-5-0, Exterior(2R) 19-5-0 to 24-3-12, Interior (1) 24-3-12 to 35-4-4 zone; cantilever left exposed ; porch left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pg=20.0 psf; Pf=20.4 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10, Lu=50-0-0; Min. flat roof snow load governs. Rain surcharge applied to all exposed surfaces with slopes less than 0.500/12 in accordance with IBC 1608.3.4. 4) Unbalanced snow loads have been considered for this design. 5) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 15.4 psf on overhangs non-concurrent with other live loads. 6) Provide adequate drainage to prevent water ponding. 7) All plates are 3x4 MT20 unless otherwise indicated. 8) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 9) Refer to girder(s) for truss to truss connections. 10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 263 lb uplift at joint 12, 17 lb uplift at joint 21 and 436 lb uplift at joint 19. 11) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 12) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. LOAD CASE(S) Standard Job Truss Truss Type Qty Ply DWH - Woodside at West Clay Lot 29 T10 3 12004899-12T Piggyback Base Job Reference (optional) Run: 8.4 S 0 Apr 7 2020 Print: 8.400 S Apr 7 2020 MiTek Industries, Inc. Wed Jun 10 15:42:17 Page: 1 ID:2lJbK?AA95YvhvH3ewm2nZzX6hk-xvvso0hT6eXq5ZLd3LoNxUlaegUfBwM29Em i6pz7fHa 07/07/20 William Hohlt DE Job # 73384-W2 1 Dansco Engineering, LLC Date: 06/11/2020 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. 22 21 19 14 13 12 1 17 16 15 2 18 3 4 5 6 87 9 10 11 T2 T1 T3 T4 W16 W1 B1 B2 B3 B4 B5 W7 W12W13 W15 W14 W16 W17 W5 W6 W10 W11 W9 W3 W4 W2 W8 W12 0-1-14 Scale = 1:67.3 Plate Offsets (X, Y): [2:0-2-15,0-2-0], [6:0-2-12,0-2-0], [8:0-2-12,0-2-0], [15:0-3-0,0-2-8] Loading (psf) Spacing 2-0-0 CSI DEFL in (loc) l/defl L/d PLATES GRIP TCLL (roof) 20.0 Plate Grip DOL 1.15 TC 0.77 Vert(LL) -0.07 17-18 >999 360 MT20 197/144 Snow (Pf/Pg) 20.4/20.0 Lumber DOL 1.15 BC 0.47 Vert(CT) -0.15 17-18 >999 240 TCDL 10.0 Rep Stress Incr YES WB 0.93 Horz(CT) 0.02 12 n/a n/a BCLL 0.0 Code IRC2018/TPI2014 Matrix-MSH BCDL 10.0 Weight: 262 lb FT = 20% LUMBER TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 *Except* B2:2x4 SPF Stud WEBS 2x4 SPF No.2 *Except* W7,W15,W1,W5,W6,W3,W4,W2,W8:2x4 SPF Stud BRACING TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 7-11. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. Except: 1 Row at midpt 9-15 WEBS 1 Row at midpt 11-12, 8-15, 10-13, 7-17, 8-17 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS (lb/size) 12=922/ Mechanical, (min. 0-1-8), 20=1573/0-6-0, (min. 0-2-12), 22=224/0-4-0, (min. 0-1-8) Max Horiz 22=419 (LC 16) Max Uplift 12=-261 (LC 13), 20=-439 (LC 16), 22=-13 (LC 12) Max Grav 12=1171 (LC 37), 20=1749 (LC 38), 22=272 (LC 2) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 3-4=-281/342, 4-24=-269/371, 5-24=-269/434, 6-25=-659/86, 25-26=-642/89, 7-26=-599/118, 7-8=-537/138, 8-9=-670/159, 9-27=-674/163, 10-27=-674/163, 10-28=-485/109, 11-28=-485/109, 11-12=-1121/282 BOT CHORD 22-29=-433/211, 21-29=-433/211, 20-21=-361/69, 6-18=-933/290, 16-17=-152/612, 15-16=-152/612, 9-15=-362/136 WEBS 18-20=-423/68, 13-15=-110/423, 10-15=-105/367, 10-13=-866/293, 11-13=-233/1032, 5-20=-1240/351, 5-18=-199/887, 8-17=-374/136, 6-17=-99/668, 3-21=-295/217, 3-20=-435/475 NOTES 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=5.0psf; BCDL=5.0psf; h=30ft; Cat. II; Exp C; Enclosed; MWFRS (envelope) exterior zone and C-C Exterior(2E) -1-2-12 to 2-3-14, Interior (1) 2-3-14 to 19-6-4, Exterior(2R) 19-6-4 to 24-3-12, Interior (1) 24-3-12 to 35-4-4 zone; cantilever left exposed ; end vertical left exposed; porch left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pg=20.0 psf; Pf=20.4 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10, Lu=50-0-0; Min. flat roof snow load governs. Rain surcharge applied to all exposed surfaces with slopes less than 0.500/12 in accordance with IBC 1608.3.4. 3) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 15.4 psf on overhangs non-concurrent with other live loads. 5) Provide adequate drainage to prevent water ponding. 6) All plates are 3x4 MT20 unless otherwise indicated. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) Refer to girder(s) for truss to truss connections. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 261 lb uplift at joint 12, 13 lb uplift at joint 22 and 439 lb uplift at joint 20. 10) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 11) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. LOAD CASE(S) Standard Job Truss Truss Type Qty Ply DWH - Woodside at West Clay Lot 29 T11 1 12004899-12T Piggyback Base Job Reference (optional) Run: 8.4 S 0 Apr 7 2020 Print: 8.400 S Apr 7 2020 MiTek Industries, Inc. Wed Jun 10 15:42:18 Page: 1 ID:W COO69OTwdpLsgfWhi5GWMzX6hS-P5TF?Lh5tyfhjjwpd3JcUhIlL4qrwNZCO uW FeFz7fHZ 07/07/20 William Hohlt DE Job # 73384-W2 1 Dansco Engineering, LLC Date: 06/11/2020 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. 612 24 23 21 15 14 13 1 19 18 17 16 2 20 3 4 5 6 7 8 9 10 11 12 T2 T1 T3 T4 T5 W19 W1 B1 B5 B2 B3 B4 W7 W9 W10 W11W12 W13 W14 W15 W18 W17 W19 W20 W5 W6 W3 W4 W2 W8 W16 Scale = 1:66.2 Plate Offsets (X, Y): [2:0-2-15,0-2-0], [6:0-1-12,0-2-0], [8:0-3-12,Edge], [9:0-3-0,0-2-0], [16:0-3-0,0-2-8] Loading (psf) Spacing 2-0-0 CSI DEFL in (loc) l/defl L/d PLATES GRIP TCLL (roof) 20.0 Plate Grip DOL 1.15 TC 0.63 Vert(LL) 0.03 23-24 >999 360 MT20 197/144 Snow (Pf/Pg) 20.4/20.0 Lumber DOL 1.15 BC 0.27 Vert(CT) -0.08 14-15 >999 240 TCDL 10.0 Rep Stress Incr YES WB 0.96 Horz(CT) 0.02 13 n/a n/a BCLL 0.0 Code IRC2018/TPI2014 Matrix-MSH BCDL 10.0 Weight: 275 lb FT = 20% LUMBER TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 *Except* B2:2x4 SPF Stud WEBS 2x4 SPF No.2 *Except* W7,W9,W18,W1,W5,W6,W3,W4,W2,W8:2x4 SPF Stud BRACING TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 7-8, 9-12. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing, Except: 6-0-0 oc bracing: 23-24,22-23,20-21. 1 Row at midpt 10-16 WEBS 1 Row at midpt 12-13, 8-19, 8-17, 9-17, 9-16, 11-14 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS (lb/size) 13=919/ Mechanical, (min. 0-1-8), 22=1579/0-6-0, (min. 0-2-14), 24=221/0-4-0, (min. 0-1-8) Max Horiz 24=419 (LC 16) Max Uplift 13=-250 (LC 13), 22=-466 (LC 16), 24=-16 (LC 12) Max Grav 13=1161 (LC 43), 22=1823 (LC 44), 24=268 (LC 2) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 4-5=-308/440, 6-26=-502/62, 26-27=-460/70, 7-27=-458/78, 7-8=-413/103, 8-9=-690/146, 9-10=-657/151, 10-28=-663/152, 28-29=-663/152, 29-30=-663/152, 11-30=-663/152, 11-31=-480/104, 12-31=-480/104, 12-13=-1112/271 BOT CHORD 24-32=-458/212, 23-32=-458/212, 22-23=-368/78, 6-20=-913/287, 18-19=-173/550, 17-18=-173/551, 16-17=-159/594, 10-16=-377/140 WEBS 20-22=-414/46, 6-19=-139/715, 8-19=-579/99, 14-16=-106/416, 11-16=-118/354, 11-14=-855/281, 12-14=-220/1021, 5-22=-1273/386, 5-20=-214/821, 4-23=-299/219, 4-22=-466/476 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=5.0psf; BCDL=5.0psf; h=30ft; Cat. II; Exp C; Enclosed; MWFRS (envelope) exterior zone and C-C Exterior(2E) -1-2-12 to 2-3-14, Interior (1) 2-3-14 to 16-6-4, Exterior(2E) 16-6-4 to 18-4-4, Interior (1) 18-4-4 to 21-3-0, Exterior(2R) 21-3-0 to 24-9-10, Interior (1) 24-9-10 to 35-4-4 zone; cantilever left exposed ; end vertical left exposed; porch left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pg=20.0 psf; Pf=20.4 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10, Lu=50-0-0; Min. flat roof snow load governs. Rain surcharge applied to all exposed surfaces with slopes less than 0.500/12 in accordance with IBC 1608.3.4. 4) Unbalanced snow loads have been considered for this design. 5) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 15.4 psf on overhangs non-concurrent with other live loads. 6) Provide adequate drainage to prevent water ponding. 7) All plates are 3x4 MT20 unless otherwise indicated. 8) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 9) Refer to girder(s) for truss to truss connections. 10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 250 lb uplift at joint 13, 16 lb uplift at joint 24 and 466 lb uplift at joint 22. 11) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 12) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. LOAD CASE(S) Standard Job Truss Truss Type Qty Ply DWH - Woodside at West Clay Lot 29 T12 1 12004899-12T Piggyback Base Job Reference (optional) Run: 8.4 S 0 Apr 7 2020 Print: 8.400 S Apr 7 2020 MiTek Industries, Inc. Wed Jun 10 15:42:19 Page: 1 ID:LMlgNDTEVTaVab6g2zCgldzX6hM-tH1dDhikeGnYLtV?Amqr0vqzNUCFfqPLcYFoAiz7fHY 07/07/20 William Hohlt DE Job # 73384-W2 1 Dansco Engineering, LLC Date: 06/11/2020 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. 612 24 23 21 15 14 13 1 20 19 18 17 16 2 3 4 5 6 7 8 9 10 11 12 T2 T1 T3 T4 T5 W18 W1 B1 B5 B2 B3 B4 W7 W8W9 W10W11 W12 W13 W14 W17 W16 W18 W19 W5 W6 W3 W4 W2 W15 Scale = 1:66.2 Plate Offsets (X, Y): [2:0-2-15,0-2-0], [7:0-2-8,0-1-0], [8:0-5-0,0-1-13], [9:0-4-0,0-2-8], [16:0-3-0,0-2-8] Loading (psf) Spacing 2-0-0 CSI DEFL in (loc) l/defl L/d PLATES GRIP TCLL (roof) 20.0 Plate Grip DOL 1.15 TC 0.62 Vert(LL) -0.05 10 >999 360 MT20 197/144 Snow (Pf/Pg) 20.4/20.0 Lumber DOL 1.15 BC 0.24 Vert(CT) -0.09 17-18 >999 240 TCDL 10.0 Rep Stress Incr YES WB 0.97 Horz(CT) 0.03 13 n/a n/a BCLL 0.0 Code IRC2018/TPI2014 Matrix-MSH BCDL 10.0 Weight: 263 lb FT = 20% LUMBER TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 *Except* B2:2x4 SPF Stud WEBS 2x4 SPF Stud *Except* W18,W12,W13,W14,W16,W19,W15:2x4 SPF No.2 BRACING TOP CHORD Structural wood sheathing directly applied or 5-4-6 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 7-8, 9-12. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. Except: 1 Row at midpt 10-16 WEBS 1 Row at midpt 12-13, 9-17, 9-16, 11-14 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS (lb/size) 13=923/ Mechanical, (min. 0-1-8), 22=1558/0-6-0, (min. 0-2-14), 24=237/0-4-0, (min. 0-1-8) Max Horiz 24=419 (LC 16) Max Uplift 13=-252 (LC 13), 22=-456 (LC 16), 24=-18 (LC 13) Max Grav 13=1155 (LC 43), 22=1840 (LC 44), 24=356 (LC 44) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-25=-253/100, 4-27=-296/309, 27-28=-285/342, 5-28=-276/424, 8-30=-702/107, 9-30=-663/123, 9-10=-649/149, 10-31=-655/152, 31-32=-655/152, 32-33=-655/152, 11-33=-655/152, 11-34=-477/105, 12-34=-477/105, 12-13=-1106/273, 2-24=-310/175 BOT CHORD 24-35=-462/213, 23-35=-462/213, 22-23=-378/155, 18-19=-190/416, 17-18=-189/418, 16-17=-162/591, 10-16=-364/138 WEBS 20-22=-294/9, 7-20=-786/180, 7-19=-136/726, 8-19=-864/167, 8-17=-53/268, 14-16=-110/411, 11-16=-121/346, 11-14=-849/284, 12-14=-222/1014, 5-22=-1296/393, 5-20=-207/850, 4-23=-297/214, 4-22=-546/472 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=5.0psf; BCDL=5.0psf; h=30ft; Cat. II; Exp C; Enclosed; MWFRS (envelope) exterior zone and C-C Exterior(2E) -1-2-12 to 2-3-14, Interior (1) 2-3-14 to 13-6-4, Exterior(2E) 13-6-4 to 15-4-4, Interior (1) 15-4-4 to 21-3-0, Exterior(2R) 21-3-0 to 24-9-10, Interior (1) 24-9-10 to 35-4-4 zone; cantilever left exposed ; end vertical left exposed; porch left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pg=20.0 psf; Pf=20.4 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10, Lu=50-0-0; Min. flat roof snow load governs. Rain surcharge applied to all exposed surfaces with slopes less than 0.500/12 in accordance with IBC 1608.3.4. 4) Unbalanced snow loads have been considered for this design. 5) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 15.4 psf on overhangs non-concurrent with other live loads. 6) Provide adequate drainage to prevent water ponding. 7) All plates are 3x4 MT20 unless otherwise indicated. 8) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 9) Refer to girder(s) for truss to truss connections. 10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 252 lb uplift at joint 13, 18 lb uplift at joint 24 and 456 lb uplift at joint 22. 11) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 12) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. LOAD CASE(S) Standard Job Truss Truss Type Qty Ply DWH - Woodside at West Clay Lot 29 T13 1 12004899-12T Piggyback Base Job Reference (optional) Run: 8.4 S 0 Apr 7 2020 Print: 8.400 S Apr 7 2020 MiTek Industries, Inc. Wed Jun 10 15:42:19 Page: 1 ID :djgJrcYdsdSVvg90yxqJX6zX6hF-tH1dDhikeGnYLtV?Amqr0vqzTUDgfp8LcYFoAiz7fHY 07/07/20 William Hohlt DE Job # 73384-W2 1 Dansco Engineering, LLC Date: 06/11/2020 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. 612 21 20 18 13 12 11 1 16 15 14 2 17 3 5 4 6 7 8 9 10 T1 T2 T3 T4 T5 W17 W1 B1 B5 B2 B3 B4 W3 W4 W5 W7 W6 W11 W12 W13 W16 W15 W17 W18 W2 W10 W9 W14 W8 0-1-14 Scale = 1:66.2 Plate Offsets (X, Y): [2:0-2-15,0-2-0], [5:0-2-8,0-2-8], [6:0-1-8,0-3-0], [7:0-3-0,0-2-0], [14:0-3-0,0-2-8], [17:0-2-12,0-2-8] Loading (psf) Spacing 2-0-0 CSI DEFL in (loc) l/defl L/d PLATES GRIP TCLL (roof) 20.0 Plate Grip DOL 1.15 TC 0.58 Vert(LL) 0.04 20-21 >999 360 MT20 197/144 Snow (Pf/Pg) 20.4/20.0 Lumber DOL 1.15 BC 0.24 Vert(CT) -0.07 12-13 >999 240 TCDL 10.0 Rep Stress Incr YES WB 0.91 Horz(CT) 0.02 11 n/a n/a BCLL 0.0 Code IRC2018/TPI2014 Matrix-MSH BCDL 10.0 Weight: 257 lb FT = 20% LUMBER TOP CHORD 2x4 SPF No.2 *Except* T3:2x6 SPF No.2 BOT CHORD 2x4 SPF No.2 *Except* B2:2x4 SPF Stud WEBS 2x4 SPF Stud *Except* W17,W11,W12,W13,W15,W18,W10,W14:2x4 SPF No.2 BRACING TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 4-5, 7-10. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. Except: 1 Row at midpt 8-14 WEBS 1 Row at midpt 10-11, 7-15, 7-14, 9-12 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS (lb/size) 11=892/ Mechanical, (min. 0-1-8), 19=1616/0-6-0, (min. 0-3-0), 21=211/0-4-0, (min. 0-1-8) Max Horiz 21=419 (LC 16) Max Uplift 11=-249 (LC 13), 19=-469 (LC 16), 21=-25 (LC 12) Max Grav 11=1116 (LC 43), 19=1900 (LC 44), 21=429 (LC 44) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 3-24=-295/374, 24-25=-288/400, 4-25=-282/532, 5-26=-556/28, 6-26=-416/39, 6-27=-625/109, 27-28=-593/117, 7-28=-589/127, 7-8=-604/145, 8-29=-610/148, 29-30=-610/148, 30-31=-610/148, 9-31=-610/148, 9-32=-457/103, 10-32=-457/103, 10-11=-1067/270, 2-21=-379/176 BOT CHORD 21-33=-470/221, 20-33=-470/221, 20-34=-400/131, 19-34=-400/131, 5-17=-943/192, 15-16=-175/420, 14-15=-144/529, 8-14=-374/140 WEBS 3-20=-318/234, 3-19=-611/530, 4-19=-1151/374, 17-19=-499/44, 4-17=-161/719, 6-15=-64/277, 7-14=-98/261, 12-14=-106/395, 9-14=-112/304, 9-12=-806/280, 10-12=-219/970, 6-16=-490/200, 5-16=-200/785 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=5.0psf; BCDL=5.0psf; h=30ft; Cat. II; Exp C; Enclosed; MWFRS (envelope) exterior zone and C-C Exterior(2E) -1-2-12 to 2-3-14, Interior (1) 2-3-14 to 10-6-4, Exterior(2E) 10-6-4 to 12-4-0, Interior (1) 12-4-0 to 21-3-0, Exterior(2R) 21-3-0 to 24-9-10, Interior (1) 24-9-10 to 35-4-4 zone; cantilever left exposed ; end vertical left exposed; porch left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pg=20.0 psf; Pf=20.4 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10, Lu=50-0-0; Min. flat roof snow load governs. Rain surcharge applied to all exposed surfaces with slopes less than 0.500/12 in accordance with IBC 1608.3.4. 4) Unbalanced snow loads have been considered for this design. 5) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 15.4 psf on overhangs non-concurrent with other live loads. 6) Provide adequate drainage to prevent water ponding. 7) All plates are 3x4 MT20 unless otherwise indicated. 8) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 9) Refer to girder(s) for truss to truss connections. 10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 249 lb uplift at joint 11, 25 lb uplift at joint 21 and 469 lb uplift at joint 19. 11)This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 12) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. LOAD CASE(S) Standard Job Truss Truss Type Qty Ply DWH - Woodside at West Clay Lot 29 T14 1 12004899-12T Piggyback Base Job Reference (optional) Run: 8.4 S 0 Apr 7 2020 Print: 8.400 S Apr 7 2020 MiTek Industries, Inc. Wed Jun 10 15:42:20 Page: 1 ID:OA2dF5p__Bu0jSZURKlF6SzX6iB-LUa?Q1jMPZvPz14CkUL4Z6N8muZwOHSVrC?Mj8z7fHX 07/07/20 William Hohlt DE Job # 73384-W2 1 Dansco Engineering, LLC Date: 06/11/2020 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. 22 21 20 19 14 13 12 1 17 16 15 2 18 3 4 5 6 7 8 9 10 11 T1 T2 T3 T4 W18 W1 B1 B5 B2 B3 B4 W4 W5 W6 W8 W7 W10 W12 W13 W14 W17 W16 W18 W19 W2 W11 W3 W9 W15 0-1-14 Scale = 1:66.2 Plate Offsets (X, Y): [5:0-3-12,Edge], [6:0-1-12,0-2-0], [8:0-3-0,0-2-0], [15:0-3-0,0-2-8], [18:0-2-0,0-2-8] Loading (psf) Spacing 2-0-0 CSI DEFL in (loc) l/defl L/d PLATES GRIP TCLL (roof) 20.0 Plate Grip DOL 1.15 TC 0.62 Vert(LL) 0.16 21-22 >685 360 MT20 197/144 Snow (Pf/Pg) 20.4/20.0 Lumber DOL 1.15 BC 0.35 Vert(CT) -0.14 21-22 >804 240 TCDL 10.0 Rep Stress Incr YES WB 0.59 Horz(CT) 0.02 12 n/a n/a BCLL 0.0 Code IRC2018/TPI2014 Matrix-MSH BCDL 10.0 Weight: 256 lb FT = 20% LUMBER TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 *Except* B2:2x4 SPF Stud WEBS 2x4 SPF No.2 *Except* W4,W5,W6,W8,W7,W10,W17,W2,W3,W9:2x4 SPF Stud BRACING TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 4-5, 8-11. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing, Except: 6-0-0 oc bracing: 21-22,20-21. 1 Row at midpt 9-15 WEBS 1 Row at midpt 11-12, 7-16, 8-16, 8-15, 10-13 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS (lb/size) 12=936/0-6-0, (min. 0-1-13), 20=1595/0-6-0, (min. 0-3-0), 22=187/0-4-0, (min. 0-1-8) Max Horiz 22=419 (LC 16) Max Uplift 12=-258 (LC 13), 20=-486 (LC 16), 22=-32 (LC 12) Max Grav 12=1154 (LC 43), 20=1902 (LC 44), 22=379 (LC 47) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 4-25=-239/304, 4-5=-280/491, 6-26=-710/71, 26-27=-618/72, 7-27=-553/81, 7-28=-701/140, 8-28=-653/158, 8-9=-649/162, 9-29=-655/164, 29-30=-655/164, 30-31=-655/164, 10-31=-655/164, 10-32=-477/108, 11-32=-477/108, 11-12=-1105/279, 2-22=-287/216 BOT CHORD 22-33=-400/139, 33-34=-400/139, 21-34=-400/139, 6-18=-978/250, 16-17=-195/561, 15-16=-175/585, 9-15=-375/140 WEBS 4-21=-539/341, 4-20=-676/696, 5-20=-1004/216, 18-20=-582/69, 5-18=-260/1046, 6-17=-114/591, 13-15=-110/413, 10-15=-135/367, 10-13=-848/290, 11-13=-229/1013, 7-17=-361/141, 3-21=-349/221 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=5.0psf; BCDL=5.0psf; h=30ft; Cat. II; Exp C; Enclosed; MWFRS (envelope) exterior zone and C-C Exterior(2E) -1-2-12 to 2-3-14, Interior (1) 2-3-14 to 7-6-4, Exterior(2E) 7-6-4 to 9-4-4, Interior (1) 9-4-4 to 21-3-0, Exterior(2R) 21-3-0 to 24-9-10, Interior (1) 24-9-10 to 35-4-4 zone; cantilever left exposed ; end vertical left exposed; porch left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pg=20.0 psf; Pf=20.4 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10, Lu=50-0-0; Min. flat roof snow load governs. Rain surcharge applied to all exposed surfaces with slopes less than 0.500/12 in accordance with IBC 1608.3.4. 4) Unbalanced snow loads have been considered for this design. 5) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 15.4 psf on overhangs non-concurrent with other live loads. 6) Provide adequate drainage to prevent water ponding. 7) All plates are 3x4 MT20 unless otherwise indicated. 8) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 258 lb uplift at joint 12, 486 lb uplift at joint 20 and 32 lb uplift at joint 22. 10) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 11) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. LOAD CASE(S) Standard Job Truss Truss Type Qty Ply DWH - Woodside at West Clay Lot 29 T15 1 12004899-12T Piggyback Base Job Reference (optional) Run: 8.4 S 0 Apr 7 2020 Print: 8.400 S Apr 7 2020 MiTek Industries, Inc. Wed Jun 10 15:42:20 Page: 1 ID:O DCMm oVEiUHW BS9Dv?3HhazWmcq-LUa?Q1jMPZvPz14CkUL4Z6N8DuX7OMRVrC?Mj8z7fHX 07/07/20 William Hohlt DE Job # 73384-W2 1 Dansco Engineering, LLC Date: 06/11/2020 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. 20 19 18 16 15 14 13 12 11 1 2 3 4 5 6 7 8 9 10 T1 T2 T4 T3 T5 W13 W1 B1 B3B2 W3 W4 W5 W6 W11 W12 W13 W12 W2 W7 W10W9 W80-1-14 Scale = 1:66.2 Plate Offsets (X, Y): [2:0-2-15,0-2-0], [4:0-3-12,Edge], [8:0-4-0,0-2-8] Loading (psf) Spacing 2-0-0 CSI DEFL in (loc) l/defl L/d PLATES GRIP TCLL (roof) 20.0 Plate Grip DOL 1.15 TC 0.91 Vert(LL) 0.03 19-20 >999 360 MT20 197/144 Snow (Pf/Pg) 20.4/20.0 Lumber DOL 1.15 BC 0.43 Vert(CT) -0.14 11-12 >999 240 TCDL 10.0 Rep Stress Incr YES WB 0.76 Horz(CT) -0.01 11 n/a n/a BCLL 0.0 Code IRC2018/TPI2014 Matrix-MSH BCDL 10.0 Weight: 203 lb FT = 20% LUMBER TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 *Except* W3,W4,W5,W6,W1,W2,W7:2x4 SPF Stud BRACING TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (3-1-0 max.): 3-4, 8-10. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. WEBS 1 Row at midpt 10-11, 8-13, 8-12, 9-12, 7-13 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS (lb/size) 11=961/0-6-0, (min. 0-1-14), 17=1415/0-6-0, (min. 0-2-11), 20=346/0-4-0, (min. 0-1-8) Max Horiz 20=419 (LC 16) Max Uplift 11=-267 (LC 13), 17=-392 (LC 16), 20=-65 (LC 12) Max Grav 11=1177 (LC 43), 17=1721 (LC 44), 20=524 (LC 44) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-21=-353/197, 21-22=-337/199, 22-23=-270/206, 3-23=-260/216, 4-5=-259/180, 6-24=-707/39, 24-25=-596/40, 7-25=-510/53, 7-26=-709/113, 8-26=-624/136, 8-27=-585/137, 27-28=-585/137, 9-28=-585/137, 9-29=-585/137, 10-29=-585/137, 10-11=-1114/295, 2-20=-482/241 BOT CHORD 20-30=-495/219, 30-31=-495/219, 19-31=-495/219, 18-19=-496/232, 17-18=-370/153, 14-15=-217/541, 13-14=-217/541, 12-13=-162/570 WEBS 3-18=-187/267, 4-18=-360/192, 4-17=-364/449, 9-12=-729/272, 10-12=-242/1035, 6-17=-1375/361, 7-13=-83/253, 7-15=-502/197, 6-15=-196/900 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=5.0psf; BCDL=5.0psf; h=30ft; Cat. II; Exp C; Enclosed; MWFRS (envelope) exterior zone and C-C Exterior(2E) -1-2-12 to 2-3-14, Interior (1) 2-3-14 to 4-6-4, Exterior(2E) 4-6-4 to 6-4-4, Interior (1) 6-4-4 to 21-3-0, Exterior(2R) 21-3-0 to 24-9-10, Interior (1) 24-9-10 to 35-4-4 zone; cantilever left exposed ; end vertical left exposed; porch left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pg=20.0 psf; Pf=20.4 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10, Lu=50-0-0; Min. flat roof snow load governs. Rain surcharge applied to all exposed surfaces with slopes less than 0.500/12 in accordance with IBC 1608.3.4. 4) Unbalanced snow loads have been considered for this design. 5) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 15.4 psf on overhangs non-concurrent with other live loads. 6) Provide adequate drainage to prevent water ponding. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 267 lb uplift at joint 11, 65 lb uplift at joint 20 and 392 lb uplift at joint 17. 9) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 10) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. LOAD CASE(S) Standard Job Truss Truss Type Qty Ply DWH - Woodside at West Clay Lot 29 T16 1 12004899-12T Piggyback Base Job Reference (optional) Run: 8.4 S 0 Mar 10 2020 Print: 8.400 S Apr 7 2020 MiTek Industries, Inc. Wed Jun 10 15:42:21 Page: 1 ID:tmOspCYBSv6JVfjlx3cSAjzWmbU-pg8NeNk_At1GaBfOIBsJ5KwEQIs87n_e4skvFaz7fHW 07/07/20 William Hohlt DE Job # 73384-W2 1 Dansco Engineering, LLC Date: 06/11/2020 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. 612 19 18 17 16 15 14 13 12 11 1 2 3 4 5 6 7 8 9 10 T2 T1 T3 T4 W1 W11 B1 B1B2 W6 W7 W2 W9W8 W8 W9 W10 W3 W4 W5 Scale = 1:65 Plate Offsets (X, Y): [2:0-3-0,0-1-8], [6:0-3-0,0-2-0] Loading (psf) Spacing 2-0-0 CSI DEFL in (loc) l/defl L/d PLATES GRIP TCLL (roof) 20.0 Plate Grip DOL 1.15 TC 0.66 Vert(LL) -0.10 17-18 >999 360 MT20 197/144 Snow (Pf/Pg) 20.4/20.0 Lumber DOL 1.15 BC 0.54 Vert(CT) -0.21 15-17 >999 240 TCDL 10.0 Rep Stress Incr YES WB 0.84 Horz(CT) 0.05 11 n/a n/a BCLL 0.0 Code IRC2018/TPI2014 Matrix-MSH BCDL 10.0 Weight: 220 lb FT = 20% LUMBER TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 *Except* W1,W2,W3:2x4 SPF Stud, W11:2x6 SPF No.2 BRACING TOP CHORD Structural wood sheathing directly applied or 3-8-12 oc purlins, except end verticals, and 2-0-0 oc purlins (5-0-15 max.): 6-10. BOT CHORD Rigid ceiling directly applied or 7-2-11 oc bracing. WEBS 1 Row at midpt 5-15, 10-11, 7-13, 6-13, 9-12 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS (lb/size) 11=1386/0-6-0, (min. 0-2-8), 19=1370/0-6-0, (min. 0-2-6) Max Horiz 19=419 (LC 16) Max Uplift 11=-355 (LC 13), 19=-300 (LC 16) Max Grav 11=1610 (LC 37), 19=1521 (LC 38) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-20=-2207/360, 3-20=-2135/364, 3-4=-2074/379, 4-21=-1996/333, 5-21=-1787/359, 5-22=-1453/276, 6-22=-1344/302, 6-7=-1075/249, 7-23=-1075/249, 8-23=-1075/249, 8-9=-1075/249, 9-24=-700/156, 10-24=-700/156, 2-19=-1454/328, 10-11=-1558/377 BOT CHORD 18-19=-501/337, 17-18=-668/1910, 16-17=-513/1696, 15-16=-513/1696, 14-15=-314/1193, 13-14=-314/1193, 12-13=-156/700 WEBS 5-15=-821/310, 6-15=-179/748, 2-18=-169/1746, 7-13=-505/188, 6-13=-545/205, 9-13=-230/858, 9-12=-1233/361, 10-12=-337/1513, 4-17=-261/187, 5-17=-42/366 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=5.0psf; BCDL=5.0psf; h=30ft; Cat. II; Exp C; Enclosed; MWFRS (envelope) exterior zone and C-C Exterior(2E) -1-2-12 to 2-4-7, Interior (1) 2-4-7 to 19-5-0, Exterior(2R) 19-5-0 to 24-9-9, Interior (1) 24-9-9 to 35-9-4 zone; cantilever left exposed ; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pg=20.0 psf; Pf=20.4 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10, Lu=50-0-0; Min. flat roof snow load governs. Rain surcharge applied to all exposed surfaces with slopes less than 0.500/12 in accordance with IBC 1608.3.4. 4) Unbalanced snow loads have been considered for this design. 5) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 15.4 psf on overhangs non-concurrent with other live loads. 6) Provide adequate drainage to prevent water ponding. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 300 lb uplift at joint 19 and 355 lb uplift at joint 11. 9) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 10) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. LOAD CASE(S) Standard Job Truss Truss Type Qty Ply DWH - Woodside at West Clay Lot 29 T17 3 12004899-12T Piggyback Base Job Reference (optional) Run: 8.4 S 0 Mar 10 2020 Print: 8.400 S Apr 7 2020 M iTek Industries, Inc. Wed Jun 10 15:42:22 Page: 1 ID:22u_PpuoVhQpEhjWg?4p8uzWlz0-IsilrjlcxB97C KEasvNYeXST4hAfsC_oIWUSn0z7fHV 07/07/20 William Hohlt DE Job # 73384-W2 1 Dansco Engineering, LLC Date: 06/11/2020 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. 0.00 lb/ft to 50.00 lb/ft115.00 lb/ft 3x4 31 30 26 25 24 23 22 21 20 19 18 16 1 29 28 27 2 3 4 5 1514 6 13 7 8 9 10 11 12 T2 T1 T3 T4 T5 W1 W20 B1 B5 B7B6 B2 B3 B4 W7 W10 W12 W13 W14 W13W15 W14 W14 W15 W11 W9 W6 W3 W2 W16 W17 W18 W19 W5 W4 W8 Scale = 1:80.3 Plate Offsets (X, Y): [2:0-2-11,0-2-8], [8:0-3-0,0-2-0], [12:0-3-0,0-2-0], [25:0-3-0,0-1-12], [27:0-2-12,0-3-4], [29:0-8-12,Edge] Loading (psf) Spacing 2-0-0 CSI DEFL in (loc) l/defl L/d PLATES GRIP TCLL (roof) 20.0 Plate Grip DOL 1.15 TC 0.82 Vert(LL) -0.20 6 >999 360 MT20 197/144 Snow (Pf/Pg) 20.4/20.0 Lumber DOL 1.15 BC 0.94 Vert(CT) -0.40 6 >999 240 MT18HS 197/144 TCDL 10.0 Rep Stress Incr NO WB 0.88 Horz(CT) 0.22 17 n/a n/a BCLL 0.0 Code IRC2018/TPI2014 Matrix-MSH BCDL 10.0 Weight: 308 lb FT = 20% LUMBER TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 *Except* B2,B4:2x4 SPF Stud WEBS 2x4 SPF No.2 *Except* W7,W1,W20,W9,W6,W3,W18,W19,W5,W4,W8:2x4 SPF Stud BRACING TOP CHORD Structural wood sheathing directly applied or 2-7-11 oc purlins, except end verticals, and 2-0-0 oc purlins (3-6-1 max.): 8-12. BOT CHORD Rigid ceiling directly applied or 6-4-7 oc bracing. WEBS 1 Row at midpt 7-24, 12-19, 9-23, 8-23, 11-21, 7-25, 13-18, 14-17 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS (lb/size) 17=2524/0-8-8, (min. 0-4-3), 31=1780/0-6-0, (min. 0-3-1) Max Horiz 31=286 (LC 16) Max Uplift 17=-477 (LC 17), 31=-390 (LC 16) Max Grav 17=2669 (LC 41), 31=1938 (LC 2) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-3584/899, 3-32=-3812/1021, 4-32=-3783/1024, 4-5=-3754/1035, 5-33=-3339/703, 6-33=-3275/720, 6-34=-3309/772, 34-35=-3234/779, 7-35=-3160/790, 7-8=-2280/607, 8-9=-2086/576, 9-36=-2086/576, 36-37=-2086/576, 10-37=-2086/576, 10-11=-2086/576, 11-12=-1941/543, 12-13=-1736/480, 13-38=-1216/314, 38-39=-1503/356, 14-39=-1543/361, 2-31=-1841/496 BOT CHORD 28-29=-865/3261, 27-28=-865/3261, 6-27=-331/167, 24-25=-470/2233, 23-24=-372/1971, 22-23=-344/1941, 21-22=-344/1941, 20-21=-258/1487, 19-20=-258/1487, 18-19=-241/1190 WEBS 5-27=-437/223, 7-27=-424/1304, 7-24=-759/291, 8-24=-211/777, 12-21=-240/1011, 12-19=-411/146, 9-23=-502/188, 8-23=-167/377, 11-23=-126/418, 11-21=-793/269, 7-25=-380/143, 25-27=-435/2041, 29-31=-270/29, 2-29=-748/3044, 13-19=-110/626, 13-18=-1229/321, 14-18=-358/1774, 14-17=-2713/674, 5-29=-307/243 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=5.0psf; BCDL=5.0psf; h=30ft; Cat. II; Exp C; Enclosed; MWFRS (envelope) exterior zone and C-C Exterior(2E) -1-2-12 to 3-5-7, Interior (1) 3-5-7 to 19-5-0, Exterior(2R) 19-5-0 to 26-0-8, Interior (1) 26-0-8 to 35-7-8, Exterior(2R) 35-7-8 to 42-3-0, Interior (1) 42-3-0 to 46-8-4 zone; cantilever left exposed ; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pg=20.0 psf; Pf=20.4 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10, Lu=50-0-0; Min. flat roof snow load governs. Rain surcharge applied to all exposed surfaces with slopes less than 0.500/12 in accordance with IBC 1608.3.4. 4) Unbalanced snow loads have been considered for this design. 5) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 15.4 psf on overhangs non-concurrent with other live loads. 6) Provide adequate drainage to prevent water ponding. 7) All plates are MT20 plates unless otherwise indicated. 8) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 390 lb uplift at joint 31 and 477 lb uplift at joint 17. 10) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 11) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. LOAD CASE(S) Standard 1) Dead + Snow (balanced): Lumber Increase=1.15, Plate Increase=1.15 Job Truss Truss Type Qty Ply DWH - Woodside at West Clay Lot 29 T18 1 12004899-12T Piggyback Base Job Reference (optional) Run: 8.4 S 0 Apr 7 2020 Print: 8.400 S Apr 7 2020 M iTek Industries, Inc. Wed Jun 10 15:42:22 Page: 1 ID:KAR2en1Zey3jsPxK8Ux1aozWlZ0-IsilrjlcxB97CKEasvNYeXSRYh4UsCNoIWUSn0z7fHV Continued on page 2 07/07/20 William Hohlt DE Job # 73384-W2 1 Dansco Engineering, LLC Date: 06/11/2020 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Uniform Loads (lb/ft) Vert: 1-2=-51, 2-8=-51, 8-12=-61, 12-13=-51, 30-31=-20, 27-29=-20, 16-26=-20 Trapezoidal Loads (lb/ft) Vert: 13=-165-to-38=-176, 38=-176-to-39=-205, 39=-205-to-14=-209, 14=-209-to-15=-216 Job Truss Truss Type Qty Ply DWH - Woodside at West Clay Lot 29 T18 1 12004899-12T Piggyback Base Job Reference (optional) Run: 8.4 S 0 Apr 7 2020 Print: 8.400 S Apr 7 2020 MiTek Industries, Inc. Wed Jun 10 15:42:22 Page: 2 ID:KAR2en1Zey3jsPxK8Ux1aozWlZ0-IsilrjlcxB97CKEasvNYeXSRYh4UsCNoIWUSn0z7fHV 07/07/20 William Hohlt DE Job # 73384-W2 1 Dansco Engineering, LLC Date: 06/11/2020 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. 115.00 lb/ft 0.00 lb/ft to 50.00 lb/ft 3x4 29 28 24 23 22 21 20 19 18 17 16 15 1 27 26 25 2 3 4 5 14 6 13 7 8 9 10 11 12 T2 T1 T3 T4 T5 W1 W19 B1 B5 B7B6 B2 B3 B4 W7 W10 W12 W13 W14 W13 W16 W17 W15 W14 W14 W15 W11 W9 W6 W3 W2 W5 W18 W4 W8 Scale = 1:80.7 Plate Offsets (X, Y): [2:0-2-11,0-2-8], [8:0-3-0,0-2-0], [12:0-3-0,0-2-0], [14:Edge,0-1-12], [15:0-3-8,Edge], [23:0-3-0,0-2-12], [25:0-3-0,Edge] Loading (psf) Spacing 2-0-0 CSI DEFL in (loc) l/defl L/d PLATES GRIP TCLL (roof) 20.0 Plate Grip DOL 1.15 TC 0.99 Vert(LL) -0.21 6 >999 360 MT20 197/144 Snow (Pf/Pg) 20.4/20.0 Lumber DOL 1.15 BC 0.96 Vert(CT) -0.41 6 >999 240 MT18HS 197/144 TCDL 10.0 Rep Stress Incr NO WB 0.91 Horz(CT) 0.23 15 n/a n/a BCLL 0.0 Code IRC2018/TPI2014 Matrix-MSH BCDL 10.0 Weight: 302 lb FT = 20% LUMBER TOP CHORD 2x4 SPF No.2 *Except* T5:2x4 SPF 2100F 1.8E BOT CHORD 2x4 SPF No.2 *Except* B2,B4:2x4 SPF Stud WEBS 2x4 SPF No.2 *Except* W7,W1,W9,W6,W3,W5,W4,W8:2x4 SPF Stud BRACING TOP CHORD Structural wood sheathing directly applied, except end verticals, and 2-0-0 oc purlins (3-4-13 max.): 8-12. BOT CHORD Rigid ceiling directly applied or 6-3-14 oc bracing. WEBS 1 Row at midpt 7-22, 12-17, 13-16, 14-15, 9-21, 8-21, 11-19, 7-23 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS (lb/size) 15=2480/0-6-0, (min. 0-4-2), 29=1825/0-6-0, (min. 0-3-2) Max Horiz 29=286 (LC 16) Max Uplift 15=-468 (LC 17), 29=-398 (LC 16) Max Grav 15=2623 (LC 41), 29=1984 (LC 2) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-3678/914, 3-30=-3910/1036, 4-30=-3883/1040, 4-5=-3854/1050, 5-31=-3442/726, 6-31=-3379/743, 6-32=-3411/795, 32-33=-3337/802, 7-33=-3261/812, 7-8=-2373/628, 8-9=-2184/600, 9-34=-2184/600, 34-35=-2184/600, 10-35=-2184/600, 10-11=-2184/600, 11-12=-2061/573, 12-13=-1921/523, 13-36=-1400/360, 36-37=-1615/386, 14-37=-1864/417, 2-29=-1886/502, 14-15=-2565/600 BOT CHORD 28-29=-83/254, 26-27=-879/3354, 25-26=-879/3354, 6-25=-330/167, 23-24=-51/256, 22-23=-488/2315, 21-22=-391/2054, 20-21=-373/2061, 19-20=-373/2061, 18-19=-292/1628, 17-18=-292/1628, 16-17=-296/1445 WEBS 5-25=-437/223, 7-25=-427/1323, 7-22=-754/290, 8-22=-211/773, 12-19=-232/966, 12-17=-274/161, 13-17=-83/461, 13-16=-1173/325, 9-21=-501/187, 8-21=-176/417, 11-21=-118/373, 11-19=-753/263, 7-23=-398/147, 23-25=-452/2117, 27-29=-273/29, 2-27=-760/3124, 5-27=-306/240, 14-16=-388/1899 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=5.0psf; BCDL=5.0psf; h=30ft; Cat. II; Exp C; Enclosed; MWFRS (envelope) exterior zone and C-C Exterior(2E) -1-2-12 to 3-5-7, Interior (1) 3-5-7 to 19-5-0, Exterior(2R) 19-5-0 to 26-0-8, Interior (1) 26-0-8 to 35-7-8, Exterior(2R) 35-7-8 to 42-3-0, Interior (1) 42-3-0 to 46-8-4 zone; cantilever left exposed ; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pg=20.0 psf; Pf=20.4 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10, Lu=50-0-0; Min. flat roof snow load governs. Rain surcharge applied to all exposed surfaces with slopes less than 0.500/12 in accordance with IBC 1608.3.4. 4) Unbalanced snow loads have been considered for this design. 5) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 15.4 psf on overhangs non-concurrent with other live loads. 6) Provide adequate drainage to prevent water ponding. 7) All plates are MT20 plates unless otherwise indicated. 8) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 468 lb uplift at joint 15 and 398 lb uplift at joint 29. 10) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 11) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. Job Truss Truss Type Qty Ply DWH - Woodside at West Clay Lot 29 T19 5 12004899-12T Piggyback Base Job Reference (optional) Run: 8.4 S 0 Apr 7 2020 Print: 8.400 S Apr 7 2020 MiTek Industries, Inc. Wed Jun 10 15:42:23 Page: 1 ID:QOHYtwVb28E_oWNUSFaKjKzWlUX-m3G823lEiUHzqUpmPcunAl?Zg5PKbe7xXAD0JTz7fHU Continued on page 2 07/07/20 William Hohlt DE Job # 73384-W2 1 Dansco Engineering, LLC Date: 06/11/2020 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. LOAD CASE(S) Standard 1) Dead + Snow (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (lb/ft) Vert: 1-2=-51, 2-8=-51, 8-12=-61, 12-13=-51, 28-29=-20, 25-27=-20, 15-24=-20 Trapezoidal Loads (lb/ft) Vert: 13=-165-to-36=-176, 36=-176-to-37=-205, 37=-205-to-14=-216 Job Truss Truss Type Qty Ply DWH - Woodside at West Clay Lot 29 T19 5 12004899-12T Piggyback Base Job Reference (optional) Run: 8.4 S 0 Apr 7 2020 Print: 8.400 S Apr 7 2020 MiTek Industries, Inc. Wed Jun 10 15:42:23 Page: 2 ID:QOHYtwVb28E_oWNUSFaKjKzWlUX-m3G823lEiUHzqUpmPcunAl?Zg5PKbe7xXAD0JTz7fHU 07/07/20 William Hohlt DE Job # 73384-W2 1 Dansco Engineering, LLC Date: 06/11/2020 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. 612 23 22 21 20 19 18 17 16 15 14 13 1 2 3 4 12 5 11 6 7 8 9 10 T2 T1 T3 T4 T5 W1 W13 B1 B3B2 W6 W7 W8 W7 W10 W11 W2 W12 W9W8 W8 W9 W3 W4 W5 Scale = 1:80.3 Plate Offsets (X, Y): [6:0-4-0,0-2-8], [10:0-3-0,0-2-0], [13:Edge,0-3-8], [23:Edge,0-3-8] Loading (psf) Spacing 2-0-0 CSI DEFL in (loc) l/defl L/d PLATES GRIP TCLL (roof) 20.0 Plate Grip DOL 1.15 TC 0.75 Vert(LL) -0.15 19 >999 360 MT20 197/144 Snow (Pf/Pg) 20.4/20.0 Lumber DOL 1.15 BC 0.68 Vert(CT) -0.33 19-21 >999 240 MT18HS 197/144 TCDL 10.0 Rep Stress Incr YES WB 0.62 Horz(CT) 0.11 13 n/a n/a BCLL 0.0 Code IRC2018/TPI2014 Matrix-MSH BCDL 10.0 Weight: 273 lb FT = 20% LUMBER TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 *Except* W1,W13,W3:2x4 SPF Stud BRACING TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc purlins, except end verticals, and 2-0-0 oc purlins (3-6-3 max.): 6-10. BOT CHORD Rigid ceiling directly applied or 7-3-3 oc bracing. WEBS 1 Row at midpt 5-19, 10-15, 11-14, 12-13, 7-18, 6-18, 9-17 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS (lb/size) 13=1742/0-6-0, (min. 0-3-0), 23=1785/0-6-0, (min. 0-3-1) Max Horiz 23=286 (LC 16) Max Uplift 13=-263 (LC 17), 23=-383 (LC 16) Max Grav 13=1922 (LC 41), 23=1945 (LC 2) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-24=-2904/539, 3-24=-2829/539, 3-4=-2770/553, 4-25=-2786/573, 25-26=-2687/583, 5-26=-2578/599, 5-6=-2321/587, 6-7=-2089/572, 7-27=-2089/572, 27-28=-2089/572, 8-28=-2089/572, 8-9=-2089/572, 9-10=-1943/540, 10-11=-1736/476, 11-29=-1257/326, 29-30=-1331/311, 12-30=-1422/306, 2-23=-1877/463, 12-13=-1870/416 BOT CHORD 22-23=-373/260, 21-22=-660/2532, 20-21=-523/2404, 19-20=-523/2404, 18-19=-370/1981, 17-18=-340/1943, 16-17=-255/1491, 15-16=-255/1491, 14-15=-232/1190 WEBS 5-19=-771/300, 6-19=-171/709, 10-17=-244/1007, 10-15=-435/166, 11-15=-138/652, 11-14=-958/270, 2-22=-336/2364, 12-14=-309/1590, 7-18=-501/188, 6-18=-184/363, 9-18=-131/422, 9-17=-788/274, 5-21=-31/321 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=5.0psf; BCDL=5.0psf; h=30ft; Cat. II; Exp C; Enclosed; MWFRS (envelope) exterior zone and C-C Exterior(2E) -1-2-12 to 3-5-7, Interior (1) 3-5-7 to 19-5-0, Exterior(2R) 19-5-0 to 26-0-8, Interior (1) 26-0-8 to 35-7-8, Exterior(2R) 35-7-8 to 42-3-0, Interior (1) 42-3-0 to 46-8-4 zone; cantilever left exposed ; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pg=20.0 psf; Pf=20.4 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10, Lu=50-0-0; Min. flat roof snow load governs. Rain surcharge applied to all exposed surfaces with slopes less than 0.500/12 in accordance with IBC 1608.3.4. 4) Unbalanced snow loads have been considered for this design. 5) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 15.4 psf on overhangs non-concurrent with other live loads. 6) Provide adequate drainage to prevent water ponding. 7) All plates are MT20 plates unless otherwise indicated. 8) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 383 lb uplift at joint 23 and 263 lb uplift at joint 13. 10) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 11) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. LOAD CASE(S) Standard Job Truss Truss Type Qty Ply DWH - Woodside at West Clay Lot 29 T20 1 12004899-12T Piggyback Base Job Reference (optional) Run: 8.4 S 0 Mar 10 2020 Print: 8.400 S Apr 7 2020 M iTek Industries, Inc. Wed Jun 10 15:42:24 Page: 1 ID:KbGvqcP34N?j7etf9ju8aQzWlS4-EFqWGPm sToPqReOzzKQ0jyYo9VqxKAv4mqzZsvz7fHT 07/07/20 William Hohlt DE Job # 73384-W2 1 Dansco Engineering, LLC Date: 06/11/2020 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. 115.00 lb/ft 60.00 lb/ft to 50.00 lb/ft 1 16 15 14 13 12 11 2 9 3 4 5 6 7 8 T2 T1 T3 W9 B1 B2 B3 B4 W4 W5 W7 W6 W8 W3 W2W1 Scale = 1:48.3 Plate Offsets (X, Y): [2:Edge,0-1-13], [6:0-7-4,0-2-0], [10:0-7-8,0-4-4] Loading (psf) Spacing 2-0-0 CSI DEFL in (loc) l/defl L/d PLATES GRIP TCLL (roof) 20.0 Plate Grip DOL 1.15 TC 0.87 Vert(LL) 0.18 14-16 >999 360 MT20 197/144 Snow (Pf/Pg) 15.4/20.0 Lumber DOL 1.15 BC 0.90 Vert(CT) -0.36 14-16 >689 240 TCDL 10.0 Rep Stress Incr NO WB 0.90 Horz(CT) 0.05 9 n/a n/a BCLL 0.0 Code IRC2018/TPI2014 Matrix-MSH BCDL 10.0 Weight: 99 lb FT = 20% LUMBER TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 *Except* B1:2x4 SPF 1650F 1.5E, B3:2x4 SPF Stud WEBS 2x4 SPF Stud BRACING TOP CHORD Structural wood sheathing directly applied or 2-5-3 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 5-11-11 oc bracing. Except: 10-0-0 oc bracing: 10-12 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS (lb/size) 2=1016/0-6-0, (min. 0-1-13), 9=1758/0-6-0, (min. 0-3-2) Max Horiz 2=265 (LC 16) Max Uplift 2=-325 (LC 12), 9=-585 (LC 16) Max Grav 2=1151 (LC 2), 9=1985 (LC 2) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-20=-2992/788, 3-20=-2934/802, 3-4=-2193/641, 4-21=-2152/646, 5-21=-2105/655, 5-6=-1231/383, 6-7=-582/174 BOT CHORD 2-16=-992/2846, 15-16=-992/2846, 14-15=-992/2846, 13-14=-784/2088, 7-10=-579/1576, 9-10=-133/311 WEBS 5-13=-1364/475, 6-13=-85/363, 10-13=-441/1107, 6-10=-1267/490, 7-9=-1745/744, 5-14=-26/421, 3-14=-791/276 NOTES 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=5.0psf; BCDL=5.0psf; h=30ft; Cat. II; Exp C; Enclosed; MWFRS (envelope) exterior zone and C-C Exterior(2E) -1-2-12 to 1-9-4, Interior (1) 1-9-4 to 20-10-4 zone; cantilever left exposed ; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pg=20.0 psf; Pf=15.4 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10; Min. flat roof snow load governs. 3) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 15.4 psf on overhangs non-concurrent with other live loads. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 585 lb uplift at joint 9 and 325 lb uplift at joint 2. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. LOAD CASE(S) Standard 1) Dead + Snow (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (lb/ft) Vert: 1-5=-51, 12-17=-20, 11-12=-20, 9-10=-20 Trapezoidal Loads (lb/ft) Vert: 5=-226-to-6=-220, 6=-220-to-7=-217, 7=-217-to-8=-216 Job Truss Truss Type Qty Ply DWH - Woodside at West Clay Lot 29 T21 6 12004899-12T Roof Special Job Reference (optional) Run: 8.4 S 0 Mar 10 2020 Print: 8.400 S Apr 7 2020 M iTek Industries, Inc. Wed Jun 10 15:42:24 Page: 1 ID:px2haS3?pTGH3ir?h?sHdJzWlPx-EFqW GPmsToPqReOzzKQ0jyYm HVmWK5Y4m qzZsvz7fHT 07/07/20 William Hohlt DE Job # 73384-W2 1 Dansco Engineering, LLC Date: 06/11/2020 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. 60.00 lb/ft to 40.00 lb/ft115.00 lb/ft 1 21 20 19 18 17 16 15 2 12 14 3 4 5 6 7 8 9 10 11 T2 T1 T3 W13 B1 B2 B3 B4 W8 W10 W9 W12 W11 W5 W7W6 W4 W1 W2 W3 Scale = 1:59.7 Plate Offsets (X, Y): [14:0-6-4,0-4-8] Loading (psf) Spacing 2-0-0 CSI DEFL in (loc) l/defl L/d PLATES GRIP TCLL (roof) 20.0 Plate Grip DOL 1.15 TC 0.77 Vert(LL) 0.16 20-21 >999 360 MT20 197/144 Snow (Pf/Pg) 15.4/20.0 Lumber DOL 1.15 BC 0.83 Vert(CT) -0.32 20-21 >804 240 TCDL 10.0 Rep Stress Incr NO WB 0.85 Horz(CT) 0.05 13 n/a n/a BCLL 0.0 Code IRC2018/TPI2014 Matrix-MSH BCDL 10.0 Weight: 122 lb FT = 20% LUMBER TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 *Except* B1:2x4 SPF 2100F 1.8E, B3:2x4 SPF Stud WEBS 2x4 SPF Stud *Except* W11:2x4 SPF No.2 BRACING TOP CHORD Structural wood sheathing directly applied or 2-7-12 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. Except: 10-0-0 oc bracing: 14-16 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS (lb/size) 2=1064/0-6-0, (min. 0-1-8), 13=2208/0-8-8, (min. 0-3-15) Max Horiz 2=312 (LC 16) Max Uplift 2=-334 (LC 12), 13=-730 (LC 16) Max Grav 2=1205 (LC 2), 13=2491 (LC 2) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-25=-3156/771, 3-25=-3105/781, 3-4=-2933/754, 4-5=-2881/760, 5-26=-2308/615, 6-26=-2273/625, 6-7=-2333/670, 7-8=-1353/357, 8-9=-854/201 BOT CHORD 2-21=-1016/3012, 20-21=-1016/3012, 19-20=-949/2828, 18-19=-949/2828, 17-18=-652/1817, 9-14=-528/1659, 13-14=-231/646 WEBS 8-17=-124/447, 14-17=-481/1380, 8-14=-1101/387, 10-13=-485/278, 9-13=-1922/691, 6-18=-410/189, 7-17=-1236/453, 7-18=-271/911, 5-18=-717/236, 5-20=0/262 NOTES 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=5.0psf; BCDL=5.0psf; h=30ft; Cat. II; Exp C; Enclosed; MWFRS (envelope) exterior zone and C-C Exterior(2E) -1-2-12 to 1-9-4, Interior (1) 1-9-4 to 23-0-12 zone; cantilever left exposed ; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pg=20.0 psf; Pf=15.4 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10; Min. flat roof snow load governs. 3) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 15.4 psf on overhangs non-concurrent with other live loads. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 334 lb uplift at joint 2 and 730 lb uplift at joint 13. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. LOAD CASE(S) Standard 1) Dead + Snow (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (lb/ft) Vert: 1-6=-51, 16-22=-20, 15-16=-20, 12-14=-20 Trapezoidal Loads (lb/ft) Vert: 6=-226-to-7=-222, 7=-222-to-8=-217, 8=-217-to-9=-213, 9=-213-to-10=-209, 10=-209-to-11=-206 Job Truss Truss Type Qty Ply DWH - Woodside at West Clay Lot 29 T22 1 12004899-12T Roof Special Job Reference (optional) Run: 8.4 S 0 Mar 10 2020 Print: 8.400 S Apr 7 2020 M iTek Industries, Inc. Wed Jun 10 15:42:25 Page: 1 ID:enmEb8jxqy60bT2lXakn3ozW lIe-iROuTlnUE6Xh3oy9X1xFGA4ycv8r3ZZE?Ui7OLz7fHS 07/07/20 William Hohlt DE Job # 73384-W2 1 Dansco Engineering, LLC Date: 06/11/2020 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. 115.00 lb/ft60.00 lb/ft to 0.00 lb/ft 1 22 21 20 19 18 17 16 15 2 13 3 4 5 6 7 8 910 11 12 T2 T1 T4 T3 W14 B1 B2 B3 B4 W6 W10 W12 W11 W13 W4 W1 W2 W3 W8 W7 W9 W5 Scale = 1:69 Plate Offsets (X, Y): [2:0-1-13,Edge], [7:0-5-12,0-3-0], [9:0-3-0,Edge], [10:0-1-12,0-1-8], [13:0-3-0,0-2-0], [14:0-9-12,0-3-0], [18:0-2-8,0-1-8] Loading (psf) Spacing 2-0-0 CSI DEFL in (loc) l/defl L/d PLATES GRIP TCLL (roof) 20.0 Plate Grip DOL 1.15 TC 0.29 Vert(LL) 0.28 21 >999 360 MT20 244/190 Snow (Pf/Pg) 15.4/20.0 Lumber DOL 1.15 BC 0.49 Vert(CT) -0.54 21-22 >711 240 MT18HS 244/190 TCDL 10.0 Rep Stress Incr NO WB 0.96 Horz(CT) 0.07 13 n/a n/a BCLL 0.0 Code IRC2018/TPI2014 Matrix-MSH BCDL 10.0 Weight: 276 lb FT = 20% LUMBER TOP CHORD 2x6 SP 2400F 2.0E BOT CHORD 2x6 SP 2400F 2.0E WEBS 2x4 SPF Stud *Except* W14,W10,W11,W13,W9:2x4 SPF No.2 BRACING TOP CHORD Structural wood sheathing directly applied or 3-8-14 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 6-10-13 oc bracing. Except: 10-0-0 oc bracing: 14-16 WEBS 1 Row at midpt 12-13, 10-14, 11-13, 7-18, 8-17 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS (lb/size) 2=1882/0-6-0, (min. 0-1-12), 13=2243/0-6-0, (min. 0-2-2) Max Horiz 2=495 (LC 16) Max Uplift 2=-520 (LC 16), 13=-786 (LC 16) Max Grav 2=2130 (LC 2), 13=2533 (LC 2) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-26=-6964/1938, 3-26=-6963/1946, 3-4=-6793/1873, 4-27=-6761/1875, 5-27=-6755/1878, 5-6=-6164/1794, 6-7=-5235/1530, 7-8=-3572/1009, 8-9=-1904/503, 9-10=-1560/419, 10-28=-323/16, 12-13=-259/85 BOT CHORD 2-22=-2299/6718, 21-22=-2220/6434, 20-21=-2079/5967, 19-20=-2079/5967, 18-19=-1758/4990, 17-18=-1100/3027, 16-17=-261/751, 11-14=-591/1771 WEBS 7-19=-229/944, 10-17=-741/2285, 14-17=-295/767, 10-14=-2589/948, 11-13=-1540/580, 6-21=-65/449, 5-22=-6/311, 5-21=-589/204, 8-18=-658/2162, 7-18=-2857/958, 8-17=-2816/1016, 6-19=-1385/428 NOTES 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=5.0psf; BCDL=5.0psf; h=30ft; Cat. II; Exp C; Enclosed; MWFRS (envelope) exterior zone and C-C Exterior(2E) -1-2-12 to 1-11-7, Interior (1) 1-11-7 to 31-8-4 zone; cantilever left exposed ; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pg=20.0 psf; Pf=15.4 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10; Min. flat roof snow load governs. 3) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 15.4 psf on overhangs non-concurrent with other live loads. 5) All plates are MT20 plates unless otherwise indicated. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 786 lb uplift at joint 13 and 520 lb uplift at joint 2. 8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. LOAD CASE(S) Standard 1) Dead + Snow (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (lb/ft) Vert: 1-6=-51, 10-12=-51, 16-23=-20, 15-16=-20, 13-14=-20 Trapezoidal Loads (lb/ft) Vert: 6=-226-to-7=-206, 7=-206-to-8=-186, 8=-186-to-9=-168, 9=-168-to-10=-165 Job Truss Truss Type Qty Ply DWH - Woodside at West Clay Lot 29 T23 3 12004899-12T Roof Special Job Reference (optional) Run: 8.4 S 0 Mar 10 2020 Print: 8.400 S Apr 7 2020 M iTek Industries, Inc. Wed Jun 10 15:42:25 Page: 1 ID:8iVY3bDOcJo6eqQ06?HgCczW kUL-iROuTlnUE6Xh3oy9X1xFGA446vD83YsE?Ui7OLz7fHS 07/07/20 William Hohlt DE Job # 73384-W2 1 Dansco Engineering, LLC Date: 06/11/2020 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. 1 23 22 21 20 19 18 17 16 1514 2 12 3 4 5 6 7 8 9 10 11 T2 T1 T3 T4 W15 B1 B3B2 B4 B5 W7 W8 W9 W10 W11 W13 W12 W14 W6 W1 W2 W3 W4 W5 Scale = 1:71.6 Plate Offsets (X, Y): [2:0-3-9,Edge], [7:0-4-12,0-3-4], [9:0-6-0,0-2-8], [13:0-6-4,0-3-4] Loading (psf) Spacing 2-0-0 CSI DEFL in (loc) l/defl L/d PLATES GRIP TCLL (roof) 20.0 Plate Grip DOL 1.15 TC 0.38 Vert(LL) 0.22 21 >999 360 MT20 197/144 Snow (Pf/Pg) 20.4/20.0 Lumber DOL 1.15 BC 0.88 Vert(CT) -0.43 21 >943 240 TCDL 10.0 Rep Stress Incr YES WB 0.74 Horz(CT) 0.05 12 n/a n/a BCLL 0.0 Code IRC2018/TPI2014 Matrix-MSH BCDL 10.0 Weight: 246 lb FT = 20% LUMBER TOP CHORD 2x6 SPF No.2 *Except* T4:2x4 SPF No.2 BOT CHORD 2x6 SPF No.2 *Except* B4:2x4 SPF No.2 WEBS 2x4 SPF Stud *Except* W15,W8,W9,W10,W11,W12,W14:2x4 SPF No.2 BRACING TOP CHORD Structural wood sheathing directly applied or 3-3-15 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 9-11. BOT CHORD Rigid ceiling directly applied or 6-5-8 oc bracing. Except: 10-0-0 oc bracing: 13-15 WEBS 1 Row at midpt 11-12, 7-17, 8-16, 9-13, 10-12 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS (lb/size) 2=1269/0-6-0, (min. 0-2-4), 12=1238/0-6-0, (min. 0-2-3) Max Horiz 2=500 (LC 16) Max Uplift 2=-329 (LC 16), 12=-417 (LC 16) Max Grav 2=1436 (LC 2), 12=1397 (LC 42) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-27=-4323/875, 3-27=-4299/880, 3-4=-4054/811, 4-28=-4011/815, 5-28=-4006/817, 5-6=-3393/652, 6-7=-2691/474, 7-29=-1472/183, 8-29=-1353/205, 8-30=-481/11, 30-31=-378/19, 31-32=-336/24, 9-32=-313/36 BOT CHORD 2-23=-1307/4171, 22-23=-1307/4171, 21-22=-1208/3919, 20-21=-998/3260, 19-20=-998/3260, 18-19=-784/2601, 17-18=-784/2601, 16-17=-407/1246, 10-13=-364/1157 WEBS 7-19=-115/640, 7-17=-1647/447, 8-17=-177/1063, 8-16=-1480/493, 9-16=-251/1013, 9-13=-1171/389, 10-12=-1138/377, 6-19=-882/288, 3-22=-319/130, 5-22=0/268, 5-21=-748/238, 6-21=-72/430 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=5.0psf; BCDL=5.0psf; h=30ft; Cat. II; Exp C; Enclosed; MWFRS (envelope) exterior zone and C-C Exterior(2E) -1-2-12 to 2-2-4, Interior (1) 2-2-4 to 31-8-8, Exterior(2E) 31-8-8 to 34-0-4 zone; cantilever left exposed ; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pg=20.0 psf; Pf=20.4 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10, Lu=50-0-0; Min. flat roof snow load governs. Rain surcharge applied to all exposed surfaces with slopes less than 0.500/12 in accordance with IBC 1608.3.4. 4) Unbalanced snow loads have been considered for this design. 5) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 15.4 psf on overhangs non-concurrent with other live loads. 6) Provide adequate drainage to prevent water ponding. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 417 lb uplift at joint 12 and 329 lb uplift at joint 2. 9) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 10) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. LOAD CASE(S) Standard Job Truss Truss Type Qty Ply DWH - Woodside at West Clay Lot 29 T24 3 12004899-12T Piggyback Base Job Reference (optional) Run: 8.4 S 0 Mar 10 2020 Print: 8.400 S Apr 7 2020 M iTek Industries, Inc. Wed Jun 10 15:42:25 Page: 1 ID :xgcWm nZiXP5zIxWm1N2ZkWzWkBq-iROuTlnUE6Xh3oy9X1xFGA43iv733bHE?Ui7OLz7fHS 07/07/20 William Hohlt DE Job # 73384-W2 1 Dansco Engineering, LLC Date: 06/11/2020 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. 22 21 20 19 18 17 16 15 1413 1 11 2 3 4 5 6 7 8 9 10 T2 T1 T3 T4 W15 B1 B3B2 B4 B5 W7 W8 W9 W10 W11 W13 W12 W14 W6 W1 W2 W3 W4 W5 Scale = 1:69.9 Plate Offsets (X, Y): [1:0-3-9,Edge], [6:0-4-12,0-3-4], [8:0-6-0,0-2-8], [12:0-6-4,0-3-4] Loading (psf) Spacing 2-0-0 CSI DEFL in (loc) l/defl L/d PLATES GRIP TCLL (roof) 20.0 Plate Grip DOL 1.15 TC 0.38 Vert(LL) 0.22 20-21 >999 360 MT20 197/144 Snow (Pf/Pg) 20.4/20.0 Lumber DOL 1.15 BC 0.88 Vert(CT) -0.44 20 >939 240 TCDL 10.0 Rep Stress Incr YES WB 0.74 Horz(CT) 0.05 11 n/a n/a BCLL 0.0 Code IRC2018/TPI2014 Matrix-MSH BCDL 10.0 Weight: 244 lb FT = 20% LUMBER TOP CHORD 2x6 SPF No.2 *Except* T4:2x4 SPF No.2 BOT CHORD 2x6 SPF No.2 *Except* B4:2x4 SPF No.2 WEBS 2x4 SPF Stud *Except* W15,W8,W9,W10,W11,W12,W14:2x4 SPF No.2 BRACING TOP CHORD Structural wood sheathing directly applied or 3-3-8 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 8-10. BOT CHORD Rigid ceiling directly applied or 6-5-0 oc bracing. Except: 10-0-0 oc bracing: 12-14 WEBS 1 Row at midpt 10-11, 6-16, 7-15, 8-12, 9-11 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS (lb/size) 1=1205/0-6-0, (min. 0-2-2), 11=1239/0-6-0, (min. 0-2-3) Max Horiz 1=489 (LC 16) Max Uplift 1=-296 (LC 16), 11=-417 (LC 16) Max Grav 1=1361 (LC 2), 11=1397 (LC 41) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-26=-4358/894, 2-26=-4336/897, 2-3=-4068/817, 3-27=-4054/818, 4-27=-4020/824, 4-5=-3401/656, 5-6=-2695/477, 6-28=-1473/184, 7-28=-1355/205, 7-29=-481/11, 29-30=-378/20, 30-31=-336/25, 8-31=-314/37 BOT CHORD 1-22=-1323/4206, 21-22=-1323/4206, 20-21=-1214/3933, 19-20=-1001/3268, 18-19=-1001/3268, 17-18=-786/2606, 16-17=-786/2606, 15-16=-407/1246, 9-12=-364/1158 WEBS 6-18=-117/642, 6-16=-1651/449, 7-16=-178/1065, 7-15=-1481/494, 8-15=-252/1014, 8-12=-1171/389, 9-11=-1139/377, 5-18=-885/292, 2-21=-341/148, 4-21=-3/270, 4-20=-755/241, 5-20=-74/433 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=5.0psf; BCDL=5.0psf; h=30ft; Cat. II; Exp C; Enclosed; MWFRS (envelope) exterior zone and C-C Exterior(2E) 0-0-0 to 3-5-0, Interior (1) 3-5-0 to 31-8-8, Exterior(2E) 31-8-8 to 34-0-4 zone; cantilever left exposed ; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pg=20.0 psf; Pf=20.4 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10, Lu=50-0-0; Min. flat roof snow load governs. Rain surcharge applied to all exposed surfaces with slopes less than 0.500/12 in accordance with IBC 1608.3.4. 4) Unbalanced snow loads have been considered for this design. 5) Provide adequate drainage to prevent water ponding. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 417 lb uplift at joint 11 and 296 lb uplift at joint 1. 8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. LOAD CASE(S) Standard Job Truss Truss Type Qty Ply DWH - Woodside at West Clay Lot 29 T25 1 12004899-12T Piggyback Base Job Reference (optional) Run: 8.4 S 0 Mar 10 2020 Print: 8.400 S Apr 7 2020 M iTek Industries, Inc. Wed Jun 10 15:42:26 Page: 1 ID:M0leQh?PFs6U7hB?B6aJIizWk3W-AdyGh4o7?PfYhyXL5kSUoNdESJSIo2WND8Sgwoz7fHR 07/07/20 William Hohlt DE Job # 73384-W2 1 Dansco Engineering, LLC Date: 06/11/2020 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. 3x4 1.5x4 =4x4 3x4 1 7 8 2 6 3 5 4 T1 T1 B1 W1 HW1 HW1 Scale = 1:23.5 Plate Offsets (X, Y): [2:0-2-0,0-2-3], [6:0-2-6,0-0-3] Loading (psf) Spacing 2-0-0 CSI DEFL in (loc) l/defl L/d PLATES GRIP TCLL (roof) 20.0 Plate Grip DOL 1.15 TC 0.07 Vert(LL) n/a - n/a 999 MT20 197/144 Snow (Pf/Pg) 15.4/20.0 Lumber DOL 1.15 BC 0.04 Vert(CT) 0.00 8 >999 240 TCDL 10.0 Rep Stress Incr YES WB 0.03 Horz(CT) 0.00 6 n/a n/a BCLL 0.0 Code IRC2018/TPI2014 Matrix-MP BCDL 10.0 Weight: 17 lb FT = 20% LUMBER TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF Stud SLIDER Left 2x4 SPF Stud -- 1-6-0, Right 2x4 SPF Stud -- 1-6-0 BRACING TOP CHORD Structural wood sheathing directly applied or 3-8-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide.REACTIONS (lb/size) 2=175/0-4-0, (min. 0-1-8), 6=175/0-4-0, (min. 0-1-8) Max Horiz 2=56 (LC 15) Max Uplift 2=-51 (LC 16), 6=-51 (LC 17) Max Grav 2=230 (LC 23), 6=230 (LC 24) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=5.0psf; BCDL=5.0psf; h=30ft; Cat. II; Exp C; Enclosed; MWFRS (envelope) exterior zone and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pg=20.0 psf; Pf=15.4 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 4) Unbalanced snow loads have been considered for this design. 5) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 15.4 psf on overhangs non-concurrent with other live loads. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 51 lb uplift at joint 2 and 51 lb uplift at joint 6. 8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. LOAD CASE(S) Standard Job Truss Truss Type Qty Ply DWH - Woodside at West Clay Lot 29 T26 14 12004899-12T Common Job Reference (optional) Run: 8.4 S 0 Mar 10 2020 Print: 8.400 S Apr 7 2020 M iTek Industries, Inc. Wed Jun 10 15:42:26 Page: 1 ID:awgtK6waJbvASkjsStka7CzWnpm-AdyGh4o7?PfYhyXL5kSUoNdIHJfQoDdND8Sgwoz7fHR 07/07/20 William Hohlt DE Job # 73384-W2 1 Dansco Engineering, LLC Date: 06/11/2020 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. 6 12 3x4 3x4 1 3 2 T1 W1 B1 Scale = 1:15.7 Loading (psf) Spacing 2-0-0 CSI DEFL in (loc) l/defl L/d PLATES GRIP TCLL (roof) 20.0 Plate Grip DOL 1.15 TC 0.06 Vert(LL) n/a - n/a 999 MT20 197/144 Snow (Pf/Pg) 15.4/20.0 Lumber DOL 1.15 BC 0.06 Vert(TL) n/a - n/a 999 TCDL 10.0 Rep Stress Incr YES WB 0.00 Horiz(TL) n/a - n/a n/a BCLL 0.0 Code IRC2018/TPI2014 Matrix-MP BCDL 10.0 Weight: 7 lb FT = 20% LUMBER TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF Stud BRACING TOP CHORD Structural wood sheathing directly applied or 3-0-3 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS (lb/size) 1=80/2-11-11, (min. 0-1-8), 3=80/2-11-11, (min. 0-1-8) Max Horiz 1=49 (LC 13) Max Uplift 1=-19 (LC 16), 3=-31 (LC 16) Max Grav 1=101 (LC 22), 3=101 (LC 22) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=5.0psf; BCDL=5.0psf; h=30ft; Cat. II; Exp C; Enclosed; MWFRS (envelope) exterior zone and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pg=20.0 psf; Pf=15.4 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 3) Unbalanced snow loads have been considered for this design. 4) Gable requires continuous bottom chord bearing. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 31 lb uplift at joint 3 and 19 lb uplift at joint 1. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. LOAD CASE(S) Standard Job Truss Truss Type Qty Ply DWH - Woodside at West Clay Lot 29 V01 1 12004899-12T Valley Job Reference (optional) Run: 8.4 S 0 Mar 10 2020 Print: 8.400 S Apr 7 2020 M iTek Industries, Inc. Wed Jun 10 15:42:27 Page: 1 ID:twqVtaM zXF5xy62gsYiQTizWnb_-eqWeuQolmjoPI66YeSzjLbATCi?LXgKXSoBDSEz7fHQ 07/07/20 William Hohlt DE Job # 73384-W2 1 Dansco Engineering, LLC Date: 06/11/2020 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. 6 12 1.5x4 3x4 3x4 1 4 2 3 T1 W1 B1 ST1 Scale = 1:22.2 Loading (psf) Spacing 2-0-0 CSI DEFL in (loc) l/defl L/d PLATES GRIP TCLL (roof) 20.0 Plate Grip DOL 1.15 TC 0.09 Vert(LL) n/a - n/a 999 MT20 197/144 Snow (Pf/Pg) 15.4/20.0 Lumber DOL 1.15 BC 0.09 Vert(TL) n/a - n/a 999 TCDL 10.0 Rep Stress Incr YES WB 0.06 Horiz(TL) 0.00 4 n/a n/a BCLL 0.0 Code IRC2018/TPI2014 Matrix-MP BCDL 10.0 Weight: 14 lb FT = 20% LUMBER TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF Stud OTHERS 2x4 SPF Stud BRACING TOP CHORD Structural wood sheathing directly applied or 4-11-4 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS (lb/size) 1=85/4-11-4, (min. 0-1-8), 4=36/4-11-4, (min. 0-1-8), 5=218/4-11-4, (min. 0-1-8) Max Horiz 1=95 (LC 13) Max Uplift 1=-6 (LC 16), 4=-17 (LC 13), 5=-93 (LC 16) Max Grav 1=119 (LC 22), 4=50 (LC 22), 5=305 (LC 22) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=5.0psf; BCDL=5.0psf; h=30ft; Cat. II; Exp C; Enclosed; MWFRS (envelope) exterior zone and C-C Exterior(2E) 0-0-8 to 2-11-12, Interior (1) 2-11-12 to 4-10-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pg=20.0 psf; Pf=15.4 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 3) Unbalanced snow loads have been considered for this design. 4) Gable requires continuous bottom chord bearing. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 17 lb uplift at joint 4, 6 lb uplift at joint 1 and 93 lb uplift at joint 5. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. LOAD CASE(S) Standard Job Truss Truss Type Qty Ply DWH - Woodside at West Clay Lot 29 V02 1 12004899-12T Valley Job Reference (optional) Run: 8.4 S 0 Apr 7 2020 Print: 8.400 S Apr 7 2020 MiTek Industries, Inc. Wed Jun 10 15:42:27 Page: 1 ID:?CN33rjo0vGvvA9Jwgn8vlzW kCw-eqWeuQolmjoPI66YeSzjLbAShi_wXgOXSoBDSEz7fHQ 07/07/20 William Hohlt DE Job # 73384-W2 1 Dansco Engineering, LLC Date: 06/11/2020 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. 6 12 1 3 2 T1 W1 B1 Scale = 1:14.9 Plate Offsets (X, Y): [3:0-9-11,0-1-12] Loading (psf) Spacing 2-0-0 CSI DEFL in (loc) l/defl L/d PLATES GRIP TCLL (roof) 20.0 Plate Grip DOL 1.15 TC 0.02 Vert(LL) n/a - n/a 999 MT20 197/144 Snow (Pf/Pg) 15.4/20.0 Lumber DOL 1.15 BC 0.04 Vert(TL) n/a - n/a 999 TCDL 10.0 Rep Stress Incr YES WB 0.00 Horiz(TL) 0.00 3 n/a n/a BCLL 0.0 Code IRC2018/TPI2014 Matrix-MP BCDL 10.0 Weight: 4 lb FT = 20% LUMBER TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF Stud BRACING TOP CHORD Structural wood sheathing directly applied or 1-11-4 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS (lb/size) 1=63/1-11-4, (min. 0-1-8), 3=63/1-11-4, (min. 0-1-8) Max Horiz 1=30 (LC 13) Max Uplift 1=-17 (LC 16), 3=-24 (LC 16) Max Grav 1=79 (LC 22), 3=79 (LC 22) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=5.0psf; BCDL=5.0psf; h=30ft; Cat. II; Exp C; Enclosed; MWFRS (envelope) exterior zone and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pg=20.0 psf; Pf=15.4 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 3) Unbalanced snow loads have been considered for this design. 4) Gable requires continuous bottom chord bearing. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 24 lb uplift at joint 3 and 17 lb uplift at joint 1. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. LOAD CASE(S) Standard Job Truss Truss Type Qty Ply DWH - Woodside at West Clay Lot 29 V03 1 12004899-12T Valley Job Reference (optional) Run: 8.4 S 0 Apr 7 2020 Print: 8.400 S Apr 7 2020 MiTek Industries, Inc. Wed Jun 10 15:42:27 Page: 1 ID:xbVpUXk2YWWd8UJh25pc_AzWkCu-eqWeuQolmjoPI66YeSzjLbAToi?jXgKXSoBDSEz7fHQ 07/07/20 William Hohlt DE Job # 73384-W2 1 Dansco Engineering, LLC Date: 06/11/2020 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. 6 12 1 3 2 T1 W1 B1 Scale = 1:14.9 Plate Offsets (X, Y): [3:0-9-3,0-2-0] Loading (psf) Spacing 2-0-0 CSI DEFL in (loc) l/defl L/d PLATES GRIP TCLL (roof) 20.0 Plate Grip DOL 1.15 TC 0.02 Vert(LL) n/a - n/a 999 MT20 197/144 Snow (Pf/Pg) 15.4/20.0 Lumber DOL 1.15 BC 0.03 Vert(TL) n/a - n/a 999 TCDL 10.0 Rep Stress Incr YES WB 0.00 Horiz(TL) n/a - n/a n/a BCLL 0.0 Code IRC2018/TPI2014 Matrix-MP BCDL 10.0 Weight: 4 lb FT = 20% LUMBER TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF Stud BRACING TOP CHORD Structural wood sheathing directly applied or 1-11-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS (lb/size) 1=61/1-10-8, (min. 0-1-8), 3=61/1-10-8, (min. 0-1-8) Max Horiz 1=29 (LC 13) Max Uplift 1=-16 (LC 16), 3=-23 (LC 16) Max Grav 1=76 (LC 22), 3=76 (LC 22) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=5.0psf; BCDL=5.0psf; h=30ft; Cat. II; Exp C; Enclosed; MWFRS (envelope) exterior zone and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pg=20.0 psf; Pf=15.4 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 3) Unbalanced snow loads have been considered for this design. 4) Gable requires continuous bottom chord bearing. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 23 lb uplift at joint 3 and 16 lb uplift at joint 1. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. LOAD CASE(S) Standard Job Truss Truss Type Qty Ply DWH - Woodside at West Clay Lot 29 V04 1 12004899-12T Valley Job Reference (optional) Run: 8.4 S 0 Mar 10 2020 Print: 8.400 S Apr 7 2020 M iTek Industries, Inc. Wed Jun 10 15:42:27 Page: 1 ID:LAAy7ZmxrRvC?y2GjDNJcozWkCr-eqWeuQolmjoPI66YeSzjLbATqi?pXgKXSoBDSEz7fHQ 07/07/20 William Hohlt DE Job # 73384-W2 1 Dansco Engineering, LLC Date: 06/11/2020 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. 6 12 3x4 3x4 1 3 2 T1 W1 B1 Scale = 1:18.8 Loading (psf) Spacing 2-0-0 CSI DEFL in (loc) l/defl L/d PLATES GRIP TCLL (roof) 20.0 Plate Grip DOL 1.15 TC 0.31 Vert(LL) n/a - n/a 999 MT20 197/144 Snow (Pf/Pg) 15.4/20.0 Lumber DOL 1.15 BC 0.34 Vert(TL) n/a - n/a 999 TCDL 10.0 Rep Stress Incr YES WB 0.00 Horiz(TL) 0.01 3 n/a n/a BCLL 0.0 Code IRC2018/TPI2014 Matrix-MP BCDL 10.0 Weight: 13 lb FT = 20% LUMBER TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF Stud BRACING TOP CHORD Structural wood sheathing directly applied or 4-11-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS (lb/size) 1=167/4-10-8, (min. 0-1-8), 3=167/4-10-8, (min. 0-1-8) Max Horiz 1=94 (LC 13) Max Uplift 1=-42 (LC 16), 3=-64 (LC 16) Max Grav 1=234 (LC 22), 3=234 (LC 22) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-6=-398/173, 1-6=-376/175 BOT CHORD 1-3=-286/348 NOTES 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=5.0psf; BCDL=5.0psf; h=30ft; Cat. II; Exp C; Enclosed; MWFRS (envelope) exterior zone and C-C Exterior(2E) 0-0-8 to 3-0-8, Interior (1) 3-0-8 to 4-9-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pg=20.0 psf; Pf=15.4 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 3) Unbalanced snow loads have been considered for this design. 4) Gable requires continuous bottom chord bearing. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 64 lb uplift at joint 3 and 42 lb uplift at joint 1. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. LOAD CASE(S) Standard Job Truss Truss Type Qty Ply DWH - Woodside at West Clay Lot 29 V05 1 12004899-12T Valley Job Reference (optional) Run: 8.4 S 0 Mar 10 2020 Print: 8.400 S Apr 7 2020 M iTek Industries, Inc. Wed Jun 10 15:42:27 Page: 1 ID:HYIiXFoBN29wFFCfrePnhDzWkCp-eqWeuQolmjoPI66YeSzjLbAPHiwyXgKXSoBDSEz7fHQ 07/07/20 William Hohlt DE Job # 73384-W2 1 Dansco Engineering, LLC Date: 06/11/2020 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. 6 12 1.5x4 3x4 3x4 1 4 2 3 T1 W1 B1 ST1 Scale = 1:23.7 Loading (psf) Spacing 2-0-0 CSI DEFL in (loc) l/defl L/d PLATES GRIP TCLL (roof) 20.0 Plate Grip DOL 1.15 TC 0.22 Vert(LL) n/a - n/a 999 MT20 197/144 Snow (Pf/Pg) 15.4/20.0 Lumber DOL 1.15 BC 0.12 Vert(TL) n/a - n/a 999 TCDL 10.0 Rep Stress Incr YES WB 0.09 Horiz(TL) 0.00 4 n/a n/a BCLL 0.0 Code IRC2018/TPI2014 Matrix-MP BCDL 10.0 Weight: 24 lb FT = 20% LUMBER TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF Stud OTHERS 2x4 SPF Stud BRACING TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS (lb/size) 1=104/7-10-8, (min. 0-1-8), 4=103/7-10-8, (min. 0-1-8), 5=341/7-10-8, (min. 0-1-8) Max Horiz 1=158 (LC 13) Max Uplift 4=-34 (LC 13), 5=-150 (LC 16) Max Grav 1=122 (LC 30), 4=151 (LC 22), 5=433 (LC 22) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-8=-255/144 WEBS 2-5=-329/278 NOTES 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=5.0psf; BCDL=5.0psf; h=30ft; Cat. II; Exp C; Enclosed; MWFRS (envelope) exterior zone and C-C Exterior(2E) 0-0-8 to 3-0-8, Interior (1) 3-0-8 to 7-9-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pg=20.0 psf; Pf=15.4 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 3) Unbalanced snow loads have been considered for this design. 4) Gable requires continuous bottom chord bearing. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 34 lb uplift at joint 4 and 150 lb uplift at joint 5. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. LOAD CASE(S) Standard Job Truss Truss Type Qty Ply DWH - Woodside at West Clay Lot 29 V06 1 12004899-12T Valley Job Reference (optional) Run: 8.4 S 0 Mar 10 2020 Print: 8.400 S Apr 7 2020 M iTek Industries, Inc. Wed Jun 10 15:42:27 Page: 1 ID:ExQTywqRvgPdUZL1y3SFmezWkCn-eqWeuQolmjoPI66YeSzjLbAQii_PXfwXSoBDSEz7fHQ 07/07/20 William Hohlt DE Job # 73384-W2 1 Dansco Engineering, LLC Date: 06/11/2020 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. 612 1.5x4 3x4 3x4 1 4 2 3 T1 W1 B1 ST1 Scale = 1:30.3 Loading (psf) Spacing 2-0-0 CSI DEFL in (loc) l/defl L/d PLATES GRIP TCLL (roof) 20.0 Plate Grip DOL 1.15 TC 0.43 Vert(LL) n/a - n/a 999 MT20 197/144 Snow (Pf/Pg) 15.4/20.0 Lumber DOL 1.15 BC 0.40 Vert(TL) n/a - n/a 999 TCDL 10.0 Rep Stress Incr YES WB 0.12 Horiz(TL) 0.01 4 n/a n/a BCLL 0.0 Code IRC2018/TPI2014 Matrix-MP BCDL 10.0 Weight: 34 lb FT = 20% LUMBER TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF Stud OTHERS 2x4 SPF Stud BRACING TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS (lb/size) 1=198/10-10-8, (min. 0-1-8), 4=55/10-10-8, (min. 0-1-8), 5=506/10-10-8, (min. 0-1-8) Max Horiz 1=223 (LC 13) Max Uplift 1=-11 (LC 16), 4=-33 (LC 13), 5=-227 (LC 16) Max Grav 1=224 (LC 2), 4=105 (LC 22), 5=594 (LC 22) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-8=-392/167, 8-9=-273/169, 9-10=-262/198, 2-10=-259/202 BOT CHORD 1-5=-213/369 WEBS 2-5=-420/302 NOTES 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=5.0psf; BCDL=5.0psf; h=30ft; Cat. II; Exp C; Enclosed; MWFRS (envelope) exterior zone and C-C Exterior(2E) 0-0-8 to 3-0-8, Interior (1) 3-0-8 to 10-9-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pg=20.0 psf; Pf=15.4 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 3) Unbalanced snow loads have been considered for this design. 4) Gable requires continuous bottom chord bearing. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 33 lb uplift at joint 4, 11 lb uplift at joint 1 and 227 lb uplift at joint 5. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. LOAD CASE(S) Standard Job Truss Truss Type Qty Ply DWH - Woodside at West Clay Lot 29 V07 1 12004899-12T Valley Job Reference (optional) Run: 8.4 S 0 Mar 10 2020 Print: 8.400 S Apr 7 2020 M iTek Industries, Inc. Wed Jun 10 15:42:27 Page: 1 ID:AJXDN crhRHfLjtVQ4UUjr3zW kCl-eqWeuQolmjoPI66YeSzjLbANPiv0XfTXSoBDSEz7fHQ 07/07/20 William Hohlt DE Job # 73384-W2 1 Dansco Engineering, LLC Date: 06/11/2020 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. 612 1.5x4 3x4 3x4 1 5 2 3 4 T1 W1 B1 ST2 ST1 Scale = 1:35.4 Loading (psf) Spacing 2-0-0 CSI DEFL in (loc) l/defl L/d PLATES GRIP TCLL (roof) 20.0 Plate Grip DOL 1.15 TC 0.46 Vert(LL) n/a - n/a 999 MT20 197/144 Snow (Pf/Pg) 15.4/20.0 Lumber DOL 1.15 BC 0.30 Vert(TL) n/a - n/a 999 TCDL 10.0 Rep Stress Incr YES WB 0.13 Horiz(TL) 0.01 5 n/a n/a BCLL 0.0 Code IRC2018/TPI2014 Matrix-MSH BCDL 10.0 Weight: 48 lb FT = 20% LUMBER TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF Stud OTHERS 2x4 SPF Stud BRACING TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS All bearings 13-10-8. (lb) - Max Horiz 1=288 (LC 13) Max Uplift All uplift 100 (lb) or less at joint(s) 5 except 6=-124 (LC 16), 7=-185 (LC 16) Max Grav All reactions 250 (lb) or less at joint(s) 1, 5 except 6=345 (LC 22), 7=480 (LC 2) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-10=-380/208, 2-10=-365/235, 2-11=-252/136 BOT CHORD 1-7=-243/331 WEBS 3-6=-284/224, 2-7=-322/245 NOTES 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=5.0psf; BCDL=5.0psf; h=30ft; Cat. II; Exp C; Enclosed; MWFRS (envelope) exterior zone and C-C Exterior(2E) 0-0-8 to 3-0-8, Interior (1) 3-0-8 to 13-9-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pg=20.0 psf; Pf=15.4 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 3) Unbalanced snow loads have been considered for this design. 4) Gable requires continuous bottom chord bearing. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5 except (jt=lb) 6=124, 7=185. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. LOAD CASE(S) Standard Job Truss Truss Type Qty Ply DWH - Woodside at West Clay Lot 29 V08 1 12004899-12T Valley Job Reference (optional) Run: 8.4 S 0 Mar 10 2020 Print: 8.400 S Apr 7 2020 M iTek Industries, Inc. Wed Jun 10 15:42:28 Page: 1 ID:eW 5bbysKBbnCL14cdC?yOHzW kCk-60316mpNX1wGwFhkC9UytoiXh6HoG5ZghSxn?gz7fHP 07/07/20 William Hohlt DE Job # 73384-W2 1 Dansco Engineering, LLC Date: 06/11/2020 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. 612 1 7 2 3 4 5 6 T2 T1 W1 B1 B2 ST3 ST2 ST1 Scale = 1:40.4 Loading (psf) Spacing 2-0-0 CSI DEFL in (loc) l/defl L/d PLATES GRIP TCLL (roof) 20.0 Plate Grip DOL 1.15 TC 0.21 Vert(LL) n/a - n/a 999 MT20 197/144 Snow (Pf/Pg) 15.4/20.0 Lumber DOL 1.15 BC 0.20 Vert(TL) n/a - n/a 999 TCDL 10.0 Rep Stress Incr YES WB 0.25 Horiz(TL) 0.00 7 n/a n/a BCLL 0.0 Code IRC2018/TPI2014 Matrix-MSH BCDL 10.0 Weight: 62 lb FT = 20% LUMBER TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 OTHERS 2x4 SPF Stud BRACING TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 6-7 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS All bearings 16-10-8. (lb) - Max Horiz 1=349 (LC 16) Max Uplift All uplift 100 (lb) or less at joint(s) 7 except 8=-144 (LC 16), 9=-124 (LC 16), 11=-155 (LC 16) Max Grav All reactions 250 (lb) or less at joint(s) 1, 7 except 8=402 (LC 22), 9=285 (LC 2), 11=418 (LC 2) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-14=-353/131, 2-14=-338/154, 2-3=-253/79 WEBS 5-8=-313/201, 2-11=-284/190 NOTES 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=5.0psf; BCDL=5.0psf; h=30ft; Cat. II; Exp C; Enclosed; MWFRS (envelope) exterior zone and C-C Exterior(2E) 0-0-8 to 3-0-8, Interior (1) 3-0-8 to 16-9-4 zone; cantilever left exposed ; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pg=20.0 psf; Pf=15.4 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 3) Unbalanced snow loads have been considered for this design. 4) Gable requires continuous bottom chord bearing. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 7 except (jt=lb) 8=143, 9=123, 11=154. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. LOAD CASE(S) Standard Job Truss Truss Type Qty Ply DWH - Woodside at West Clay Lot 29 V09 1 12004899-12T Valley Job Reference (optional) Run: 8.4 S 0 Mar 10 2020 Print: 8.400 S Apr 7 2020 M iTek Industries, Inc. Wed Jun 10 15:42:28 Page: 1 ID:auDL0etajC1waKE?lc1QTizW kCi-60316m pNX1wGwFhkC9Uytoibc6IMG4gghSxn?gz7fHP 07/07/20 William Hohlt DE Job # 73384-W2 1 Dansco Engineering, LLC Date: 06/11/2020 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. 9 12 =3x4 1 3 2 T1 T1 B1 Scale = 1:19.3 Plate Offsets (X, Y): [2:0-2-0,Edge] Loading (psf) Spacing 2-0-0 CSI DEFL in (loc) l/defl L/d PLATES GRIP TCLL (roof) 20.0 Plate Grip DOL 1.15 TC 0.07 Vert(LL) n/a - n/a 999 MT20 197/144 Snow (Pf/Pg) 15.4/20.0 Lumber DOL 1.15 BC 0.07 Vert(TL) n/a - n/a 999 TCDL 10.0 Rep Stress Incr YES WB 0.00 Horiz(TL) 0.00 3 n/a n/a BCLL 0.0 Code IRC2018/TPI2014 Matrix-MP BCDL 10.0 Weight: 8 lb FT = 20% LUMBER TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 BRACING TOP CHORD Structural wood sheathing directly applied or 3-5-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS (lb/size) 1=121/3-5-0, (min. 0-1-8), 3=121/3-5-0, (min. 0-1-8) Max Horiz 1=30 (LC 15) Max Uplift 1=-27 (LC 16), 3=-27 (LC 17) Max Grav 1=138 (LC 22), 3=138 (LC 23) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=5.0psf; BCDL=5.0psf; h=30ft; Cat. II; Exp C; Enclosed; MWFRS (envelope) exterior zone and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pg=20.0 psf; Pf=15.4 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 4) Unbalanced snow loads have been considered for this design. 5) Gable requires continuous bottom chord bearing. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 27 lb uplift at joint 1 and 27 lb uplift at joint 3. 8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. LOAD CASE(S) Standard Job Truss Truss Type Qty Ply DWH - Woodside at West Clay Lot 29 V10 2 12004899-12T Valley Job Reference (optional) Run: 8.4 S 0 Apr 7 2020 Print: 8.400 S Apr 7 2020 MiTek Industries, Inc. Wed Jun 10 15:42:28 Page: 1 ID:froXCBPawgD7rHmy_aRSOezWlUf-60316mpNX1wG wFhkC9Uytoidl6KTG7aghSxn?gz7fHP 07/07/20 William Hohlt