Loading...
HomeMy WebLinkAboutFloor Plan and Wall SectionENG. BY : PSC : DRAWN BY : MTO BY : FBi PROJECT # : SHEET : Micah Z. XX Micah Z. Mark H. 20-0168-00ALAN HENDERSON12011 HOOVER RD.CARMEL, IN 46032MISCELLANEOUS NOTESPAD SIZE TYPE LABEL PAD SIZE / TYPE M 14" Ø x 4" PRE-CAST N/A HEADER REFERENCEHEADER LABEL HEADER SCHEDULE H-1 SEE DETAIL (H-1) SHEET 650RED COLOR GREEN PRE-CUT GIRT SCHEDULE ORANGE YELLOW PURPLE BLUE GIRT LENGTH 18'-6" 16'-6" 15'-0" 11'-6" 8'-6" 7'-3 1/4" ( -1/16" ) ANCHORS UPLIFTLENGTHSIZE STUB / COL.LABEL FULL COLUMNS OR STUBS TYPE BRACKETCOMMENTSUPLIFT ANCHOR FASTENERS COLUMN SCHEDULE DEPTH STUB / COL. A 3-PLY 2x6 16'-0" (2)12" TR. BLOCKS (10) 10d's PER BLOCK FULL COLUMN N/A 4'-0"BY DESCRIPTIONNO. DATE 1 2020-05-21 MICAH Z. APPROVAL SET2 2020-05-27 MICAH Z. APPROVAL SET (INCL. ENGINEERING REVISIONS)........BROWN COLOR WHITE MISCELLANEOUS PRE-CUT SCHEDULE LENGTH COMMENTS * * * * MFTR/MODEL SIZELABEL ACCESSORIES OPENINGS SCHEDULE TYPE ROUGHOUT DETAIL LOCATION / COMMENTS WALKDOOR BY PURCHASER 6080 74 3/4" x 98 1/8"PURCHASER TO SUPPLY & INSTALL COMPLIANT HARDWARD FBi TO FRAMEOUT, PURCHASER TO SUPPLY & INSTALL WALKDOOR OVERHEAD BY PURCHASER 10' x 8' 9'-10 1/2" x 7-11 1/2"FBi TO FRAME OUT, PURCHASER TO SUPPLY & INSTALL OHD, SEE DOOR #2 DETAIL ON SHEET 650 MISCELLANEOUS NOTES SIDING SCREW PATTERN NOTE: LAP SCREW (THROUGH RIB) CAN BE LEFT OUT AT DRIP CAP, Z-TRIM (IF INCLUDED), & EAVE LOCATIONS DIAGONAL: (20'-0" x 30'-0") = 36'-0 1116" GUTTERS & DOWNSPOUTS BY PURCHASER 7'-6" ℄ 4'-0" 4'-0" ℄ 7'-6" 11'-6" 18'-6" 7'-6" ℄ 7'-6" ℄ 7'-6" ℄ 7'-6" 30'-0" 15'-0" 15'-0"5'-034" 9'-1012" 5'-034"20'-0"6'-6" ℄ 7'-0" ℄6'-6"℄13'-6" 6'-6"7'-0" ℄℄ ORANGE ORANGE 4'-914" 4'-914"GRAY GRAY B/ GRADE BOARD 99'-9" 100'-0" T/ F.F. 24" (R-10) RIGID INSULATION REQUIRED BY PURCHASER IF BUILDING IS CONDITIONED CONCRETE PAD UPLIFT ANCHORS FINISH FLOOR BY PURCHASER 200 WALL SECTION1 SCALE: 1 2" = 1'-0"STUB / COL. DEPTH716" OSB SHEATHING LAMINATED COLUMN 2x8 TREATED PRIMARY GRADE BOARD (4) 2x4 GIRTS @24"o.c. 3.5 12 B/ TRUSS MAX-RIB STEEL ROOFING W/ MOISTURE-LOK W/ FASTENED W/ SCREWS 2x4 PURLINS 2x6 TREATED BARGE BOARD W/ FASCIA (AJ-12) 12" METAL SOFFIT (VENTED) (1) 4" GRK SCREWS & (4) 16d NAILS EACH SIDE OF HEEL TRUSS 9" HEEL "F & J" CHANNEL ON 2x6 GIRT (SEE SHEET 650 FOR FASTENER SPECS) PRE-FRAMED OVERHANG TAIL (REFER TO OVERHANG DETAIL ON SHEET 650 FOR FASTENER SPECS) 110'-0" FUTURE GUTTERS (BY PURCHASER) SIDING (PROVIDED & INSTALLED BY PURCHASER) 110'-0" B/ TRUSS BOTTOM CHORD TIE END TRUSS 2x 6 S Y P WIN D B R A C E RAKE TRIM (P-OC) ALWAYS HAVE RIB UNDER RAKE OR BEND FLAT OF STEEL UP W/ 3 4" LIP APPLY BEAD OF CAULK UNDER RAKE @ SCREW LOCATIONS (4) 16d R.S. NAILS 200 GABLE END SECTION2 SCALE: 1 2" = 1'-0" 2x4 PURLIN BLOCKING UPSIDE-DOWN 2x8 JOIST HANGER PROVIDE SEAT CUT ON TOP EDGE OF BRACE 2x6 BARGE W/ FASCIA (FL-2) 12" METAL SOFFIT (NON-VENTED) F & J CHANNEL BUILDING WRAP: x FASTEN TO OUTSIDE FACE OF GIRTS WITH STAPLES x TAPE ALL LAPS ON GIRTS x RUN BEHIND DRIP CAP, F&J CHANNEL, & Z-TRIM x INCLUDE GABLES 2x4 CONTINUOUS NAILER PRE-CUT GIRT GIRT HELD BACK 31 2" NEW OVERHEAD JAMB SEAL200SHEET TITLE:FLOOR PLANSCALE : 1/4" = 1'-0" FLOOR PLAN COPYRIGHT FBi Buildings, Inc. 1 200 1 2 Standard Connection Details: 1. Nails shall be called out on drawings by penny weight. The following fasteners & specs have been used in design & shall be used in construction: - 10d x 1-1/2 - .148" x 11/2" - 10d - .120" x 3" threaded pneumatic - 16d - .162" x 3 1/2" common - 16d R.S. - .148" x 3 1/2" threaded hardened-steel - 20d - .177" x 4" threaded hardened-steel - 60d - .177" x 6" threaded hardened-steel - 80d - .207" x 8" threaded hardened-steel 2. Substitution of fasteners shall not be permitted without the written consent of the design engineer except as follows: - 10d nails may be used to replace 16d or 16d R.S. nails where specified at a 2:1 ratio. - 16d or 16d R.S. nails may be used to replace 10d nails where specified at a 2:3 ratio. 3. Unless noted otherwise all nails shall be evenly distributed over the connection area, placed in an orderly straight pattern, and shall be driven into the center of the narrow face of 2x members when applicable. Edge distances, end distances and spacings for nails shall be sufficient to prevent splitting of the wood. Nails that do not make a solid connection (inaccurate placement, driven between plies of lumber, etc) shall be removed and replaced or compensated with extra nails that meet the required specs. 4. Fasteners in pressure treated lumber must be hot-dipped galvanized or stainless steel. 5. All light-gauge metal connectors shall be fastened per manufacturer's specs. Wood: 1. Design and construction of all structural wood members shall be in accordance with the current or referenced issue of AF&PA-NDS with supplement. 2. Minimum grades of all wood members shall be as follows unless noted otherwise: Girts,purlins,studs & bracing - (2x4) #2 SPF or better - (2x6) purlins #2 SPF or better Columns - (2x6) #1 SYP treated & non-treated Columns - (2x8) #1 SYP treated & SS SYP non-treated Truss webs, chords, headers, joist, rafters & all other framing material #1 or #2 SYP - (2x4 & 2x6) Select Structural SYP - (2x8) MSR 2400 SYP - (2x10 & 2x12) 2.0E Fb = 3,100psi - (LVL) 3. All members in contact with soil or concrete shall be preservative-treated to min 0.8 #/c.f. retention CCA for columns/posts and UC4 Ground Contact for all others. 4. Plywood and OSB, when shown on construction documents shall be APA rated. 5. Stud wall corners and intersections shall be framed with a min. of three or more studs. 6. Load-bearing headers in a stud wall shall have a min. of one cripple under each end of the header and be fastened securely to full length studs immediately beside header. 7. Deflections of wood members shall be limited to the model building code-specified minimums. PRE-DRILLED PURLIN LABELS PRE-DRILLED BCT LABELS (2) WIND BRACES THIS END (3) WIND BRACES THIS END 200 2 1 2 AM AM AM AM AMAM AM AM AM AMAM AM AM AM AM H-1 07/16/20 David Rutti