HomeMy WebLinkAboutIA101a-CLUB-ROOM-CONSTRUCTION-PLAN-Rev.01 CONSTRUCTION PLAN
SCALE 1/4" = 1'-0"
RELEA5E0 FOR CONSTRIICTI�N
Su6jec� �o compliance with all regula�ions
of S�a�e antl Local Codes
City of Carmel
�
��n„�,�,.va�i_
DATE: 0��22�20
�
N
`
MITSCH
D E S I G N
200 S. Rangeline Ftl. I Sui�e 226
Carmel, Inaiana 46032
31 ZSI32222
wwrv. mi�schtlesign.com
u J
�
r1
�^�
1�
� �
�F--��
I� �
11 m
I �
J
Fi �
��
Z
►r-�-� Q
F-� �
w
W z
Uw
� U
O�
�
�w
Z
�
a�
w
Z
J
w
�
Z
Q
�
�
Z
Q
w
� N
r Q Q
ZJ�
W
C � Q
`aQQ
Q U 0
J O Z
i Z w
Q O �
U Q
O��
>�o
o�o
zZ�
u� mees. oesiarvs nrvo>vws �oeiewu woers ov
NViXOFSHIP Fl%Ff] IN P TPNGI9LE MEDWM1I OF E%PRESSION�
iN�IGTE� OR PRESEMED BV iHE9E DRAW IN0.S ANO
VISCII LRIGHTSeESERVE0.�IXCEPTFOR116E5
[V'Ht85LYPERMIREOINWWiING.
CLUB ROOM
CONSTRUCTION PLAN
IA101 a
CONSTRUCTION PLAN LECEND
NOT IN CONTRACT, IF APPLICABLE
EXISTING WALL OR ITEM TO REMAIN
NEW CONSTRUCTION ITEM
GENERAL CONSTRUCTION NOTES
A. REFER TO SHEET IA001 FOR DOOR AND WALL TYPES.
6. DOORS NOT INDICATED BV A DOOR Nl1MBER DESIGNATION ARE EXISTING IF APPLICABLE.
C. PROVIDEBLOCKWGINWALLSTOACCOMMODATEALLCASEWORKANDWALLMOUNTEDEpUIPMENT.
REFER TO ELECTRICAL LOCATION PLANS FOR MORE MFORMATION.
D. ALLWORKISTOBECOMPLETEOINSTRICTACCORDANCEWITHALLAPPLICABLECODES,
OR�INANCES, RULES, REGULATIONS AND STANDARDS, INCLUDING, BUT NOT LIMITED TO: THE
INDIANA BUIL�ING CODE, THE INDIANA CODES, THE INDIANA FlRE CODES, THE AMERICANS W ITH
DISABILITIES ACT (ADA), INTERNATIONAL BUILDING CODE, ANO APPLICABLE TRAOE STANDARDS. ALL
APPLICABLE RULES AND REGULATIONS ARE TO BE THE MOST CURRENT ADOPTED EDITIONS.
E THE CONTRACTOR IS RESPONSIBLE FOR FlELD VERIFYING ALL CONDITIONS AND DIMENSIONS PRIOR
TOTHESTARTOFWORK. REPORTANVOISCREPANQESTOTHEARCHITECTIDESIGNER
IMMEDIATELV.
E THE CONTRACTOR IS RESPONSIBLE FOR OBTAINING ALL LOCAL PERMITS REQUIRED FOR
COMPLETION OF THIS PROJECT.
G. ALL WORK IS TO BE COORDINATED BV THE GENERAL CONTRACTOR TO ASSURE ADEQUATE FIT,
FlNISH, SVSTEM OPERATION, AND FULL COMPLETION OF THE WORK, INCLUDING SERVICE
REQUIREMENTS OF THE OWNERS F.F.E.
H. ALLDIMENSIONSARESHOWNONTHEDRAWINGS. ANVDIMENSIONSNOTSHOWNORDEEMED
QUESTIONABLEARETOBEVERIFIEDWITHTHEARCHITECTIDESIGNER. DONOTSCALEDIMENSIONS
ON THE DRAW INGS. ALL DIMENSIONS ARE TO THE FACE OF NEW STUD, MASONRYICONCRETE
WALLS, CENTERLINE OF COW MNSIWINDOWS, OR FINISH FACE OF EXISTING WALL UNLE55 NOTED
OTHERWISE.
L CONTRACTOR IS TO SIGN EACH SHOP DRAWING SUBMITTAL HAS BEEN REVIEWED, APPROVED, AND
THAT THE CONTRACTOR COORDINATION HAS BEEN PERFORMEO.
J. DURING THE ENTIRE PERIOD OF CONSTRUCTION, ALL EXISTING EXITS, EXIT LIGHTING, FIRE
PROTECTNE DEVICES. AND ALARMS SHALL BE CONTINUOUSLV MAINTAWED.
K. FINISHE� DOOR OPENINGS IN NEW PARTITIONS SHALL BE SET4" FROM A�JACENT PERPENDICULAR
PARTITIONS, 11NLESS OTHERWISE NOTED.
L. ALL RNISH CARPENTRV IS TO BE COMPLETED IN STRICT ACCORDANCE W ITH A W.I. STANDAR�S,
PREMWM GRADE.
M. ALLRREE%TINGUISHERCABINETLOCATIONSARETOBECOORDINATEDWITHTHECONTRACTOR,
DESIGNER AND THE LOCAL FlRE OFFICIALS PRIOR TO INSTALLATION.
N. CONTRACTOR(5) SHALL PROVIDE ALL NECESSARV LABOR, MATERIALS, AND EOUIPMENT FOR THE
WORK IN THESE DOCl1MENT5, UNLESS CLEARLV NOTED "NOT IN CONTRACT" (N.I.C.). EXISTING
wORK AOJACENT TO OR IN THE AREA OF NE W W ORK SHALL BE PROTECTED BV ALL SUITABLE
MEANS NECESSARV TO PREVENTOR MINIM2E �AMAGE WHERE EXISTING WORK IS TO BE
REMOVED OR ALTERED, RESTORE ADJACEM FlNISH TO ORIGINAL CON�ITION. EXTEND/REFINISH
ALL FRAMES, BASE, AND TRIM WHERE CUTTING HAS EXPOSED ANY UNFlNISHED SURFACES. REPAIR
ANV �AMAGE TO EXISTING W ORK AND RESTORE TO ORIGINAL CONDITION.
O. CONTRACTORS SHALL KEEP WORK AREAS AND ADJACENT Pl1BLIC CORRIDORSAN� FACILITIES FREE
OF OEBRIS. MATERIALS STORE� ON SITE ARE THE RESPONSIBILITV OF THE CONTRACTOR AND
SHALL BE STORED IN A LOCATION APPROVED BY THE LANDLORD.
P. ALL PWMBING ITEMS AND/OR EQUIPMENT ITEMS ARE TO BE COORDINATE� AND VERIFIED WITH
INTERIOR ELEVATIONS PRIOR TO ROUGH-IN. ANV DISCREPANCIES SHALL BE COORDINATED W ITH
THE DESIGNER.
p. REFER TO G052 FOR MOl1NTING HEIGHTS ON ALL TOILET ACCESSORIES AND FIXTURES AS
REQUIRED.
R. COOR�INATEWITHOWNERANDFAQLITVSTAFFPROJECTPHASINGTOMINIMIZEDISRUPTIONOF
EXISTINGFACILITVSERVICES. PHASINGTOINCWOEASSl1RANCEFORCLEANAIRFLOW,WRITTEN
NOTIFlCATION OF INTERRUPTIONS, AND COMMUNICATION AUTHORITV. CONTRACTOR, OWNER, AND
FACILITV STAFF TO PLAN FOR PROCEDURES ON THE EFFECTS OF NOISE AN� VIBRATION ON HUMAN
HEALTH AND SAFETV. THE RENOVATED AREAS SHALL BE ISOLATED FROM THE OCCUPIED AREAS
DURING ALL PHASE$ OF CONSTRUCTION USING AIRTIGHT BARRIERS, AND EXHAUST AIR FLOW SHALL
BE SUFFlQENTTO MAINTAIN NEGATNE AIR PRESSURE IN THE CONSTRUCTION ZONE.
5. SUBMITTHEREQUIREDNUMBEROFSUBMITTALSFORDESIGNERREVIEWANDAPPROVALPWSONE
E%TRA COPV FOR DESIGNERS RECOR�S.
�«� CONSTRUCTION PLAN KEYNOTES
100 NBVOWNER.
101 W INE LOCKERS- SEE ELEVATIONS FOR MORE DETAIL; MILLWORKER TO BUILD, COORDINATE W ITH
OW NER AND AND DESIGNER.
O EQUIPMENT AND FIXTURE SCHEDULE
150 REFRIGERATOR;PERLICKOUTDOORADAHEIGHTUNDERCOUNTERREFRIGERATOR;HH24R031
ALTERNATIVES MUST BE ADA HEIGHT 8 MADE FOR OUTDOORS
157 GRILL;TOBELIONPREMIUMGRILLSV500032-INCHSTAINLESSSTEELBUILTINNATURALGASGRILL
152 FlREPLACE TO BE ORTAL FIREPLACES, 130H MODEL, 50.5" VIEW ING WIDTH, DIRECT VENT PIPE. CONTACT
ADAM MORRIS W ITH GODBY HEARTH & HOME FOR MORE INFORMATION, 317-750-0630
153 VENT HOOD TO BE KITCHENAID 48" 585-11]0 CFM MOTOR CLA55 COMMERCIAL STYLE WALL MOUNT
CANOPV RANGE HOOD, STAINLESS STEEL; KVWC908JSS