HomeMy WebLinkAboutA010 Bonus Room and atic I-Joistrequired for cantilever.
BCI joist blocking
23/32" min. plywood/OSB
into each flange.
Nail with 8d nails
or rimboard closure.
®
F05
See Boise literature for
Nail Boise Rimboard
nail into each flange.
to BCI joist with 8d
Bo ise R
i
mboa
r
d
vertical load capacity.
®
F07
vertical load capacity.
See Boise literature forF07-A
of Boise joist & rimboard for
total vertical load capacity.
Sum vertical load capacities
F07-C
(stacked over wall below)
Load bearing wall above
See Boise literature for
vertical load capacity.
BCI Joist Blocking®
F06
above to bearing below.
Solid block all posts from
F08
required for cantilever.
BCI / AJS joist blocking
LVL Rim
8d nails @ 6" o.c.
®
Inverted hanger
F05-A
against top flange with 1/8"
Boise Rim Board
Web Stiffener for 14" & 16" joists.
5 - 3" (10d) nails
gap between bottom flange
1/8"
Stiffeners are required on both sides
- Hangers with side nailing.
- Any hanger with sides not
containing the top flange
with 3 - 3" (10d)
- Web stiffener nailed
of the joist.
11 7/8" joists, and
nails for 9 1/2" and
of the web when :
Point Load from above > 1500 lbs. (Factored)
Install web stiffeners tight
For Point Load from above:
F16-E
2x block
(stacked over wall below)
1/16"
Load bearing wall aboveF09
10-10d nails.
Nail with
Filler block.
Install tight to top flange.
mount hanger load exceeds 250 lbs.
Backer block required where top
Backer block (12" wide min.)
Nail with 10- 10d nails.
Install tight to top flange.
Joist hanger
F10
(see literature)
Filler Block
Contact Boise EWP Engineering for specific conditions.
Connection valid for all applications.
Nailing 12" OC
Web-Filler
Connection
Double BCI Joist®F58 Start Framing Here 16" O.C SpacingSTART FRAMING HERE
16" O.C SPACING
Connector Summary
PlotIDQty Manuf Product Flange
H1 1 Simpson HUS1.81/10 Reverse
H2 54 IHF20112 None
Products
PlotID Net Qty Product Length Plies
FJ1-1 4 11-7/8" BCI® 5000s-1.8 36' 0" 1
FJ2-1 8 11-7/8" BCI® 5000s-1.8 32' 0" 1
FJ3-1 6 11-7/8" BCI® 5000s-1.8 28' 0" 1
FJ4-1 1 11-7/8" BCI® 5000s-1.8 24' 0" 1
FJ5-1 25 11-7/8" BCI® 5000s-1.8 20' 0" 1
FJ6-1 6 11-7/8" BCI® 5000s-1.8 16' 0" 1
FJ7-1 1 11-7/8" BCI® 5000s-1.8 14' 0" 1
FJ8-1 13 11-7/8" BCI® 5000s-1.8 12' 0" 1
FJ9-1 4 11-7/8" BCI® 5000s-1.8 4' 0" 1
FJ10-1 30 16" AJS® 24 26' 0" 1
BM-43 2 1-3/4" x 9-1/4" VERSA-LAM® 2.0 3100 SP 20' 0" 2
BM-44 2 1-3/4" x 9-1/4" VERSA-LAM® 2.0 3100 SP 20' 0" 2
BM-38 2 1-3/4" x 9-1/4" VERSA-LAM® 2.0 3100 SP 14' 0" 2
BM-39 2 1-3/4" x 9-1/4" VERSA-LAM® 2.0 3100 SP 14' 0" 2
BM-45 2 1-3/4" x 11-1/4" VERSA-LAM® 2.0 3100 SP 34' 0" 2
BM-22 3 1-3/4" x 11-7/8" VERSA-LAM® 2.0 3100 SP 28' 0" 3
BM-25 1 1-3/4" x 11-7/8" VERSA-LAM® 2.0 3100 SP 16' 0" 1
BM-26 1 1-3/4" x 11-7/8" VERSA-LAM® 2.0 3100 SP 16' 0" 1
BM-37 2 1-3/4" x 11-7/8" VERSA-LAM® 2.0 3100 SP 14' 0" 2
BM-23 2 1-3/4" x 11-7/8" VERSA-LAM® 2.0 3100 SP 12' 0" 2
BM-29 2 1-3/4" x 11-7/8" VERSA-LAM® 2.0 3100 SP 12' 0" 2
BM-27 1 1-3/4" x 11-7/8" VERSA-LAM® 2.0 3100 SP 4' 0" 1
BM-48 1 1-3/4" x 11-7/8" VERSA-LAM® 2.0 3100 SP 4' 0" 1
2x by other 1 3 1/2" x 1' 0" Generic Material 40' 0" 1
BBO7 1 3 1/2" x 1' 0" Generic Material 40' 0" 1
STEEL BEAM BY OTHERS 1 3 1/2" x 1' 0" Generic Material 22' 0" 1
2x by other 2 3 1/2" x 1' 0" Generic Material 12' 0" 1
2x by other 1 3 1/2" x 1' 0" Generic Material 10' 0" 1
Ca1 15 1" x 11-7/8" BC RIM BOARD OSB 12' 0" 1
Ca2 9 1" x 16" BC RIM BOARD OSB 12' 0" 1
assumes 2x ceiling framing
byother
verifyrooflayout withbuilder prior to shipment BBO7BM-22BM-23
STEEL BEAM BY OTHERS
H2 BM-25BM-26BM-27
H2
BM-29BM-37
2x by other BM-38BM-392x by other
BM-43BM-442x by other
2x by other
BM-45
BM-48
Ca2
Ca2Ca2FJ10-1Ca1Ca1
Ca1Ca1 Ca1Ca1 Ca1 Ca1 Ca1 Ca1
Ca1
Ca1
Ca1
Ca1
FJ9-1FJ4-1FJ7-1 H2
H2
H2
FJ9-1
FJ5-1
FJ5-1
FJ8-1
FJ2-1
FJ6-1
FJ1-1
FJ3-1
H2H2
H1H2 H2H2
1X1X1' 7"1' 4"
By:
Date:
Scale:1/4"=1'
BC FRAMER
RIMBOARDIS NOT TO BE CUT. IF A PIECE OF
RIMBOARDENDSBETWEEN TWO JOISTS, BUTT
THE NEXT PIECE UP TO IT.
Boise I-Joist can be offset up to 3" to avoid vertical plumbing.
Joist
3" max
C L Joist
3" max
C L
OJ-AFASTENALL2-PLY LVL'S UP TO 11-7/8" WITH 2 ROWS OF 16DSINKER NAILS @12" OC STAGGERED
FASTEN ALL 2-PLY LVL'S 14"-18" 3 ROWS OF 16DSINKER NAILS @12" OC STAGGERED
FASTEN ALL 2-PLY LVL'S 20"-24" WITH 2 ROWS OF 16DSINKER NAILS @12" OC STAGGERED
FASTEN ALL 3-PLY LVL'S UP TO 11-7/8" WITH 2 ROWS OF 16DSINKER NAILS @12" OC STAGGERED, FROM BOTH SIDES
FASTEN ALL 3-PLY LVL'S 14"-18" 3 ROWS OF 16DSINKER NAILS @12" OC STAGGERED, FROM BOTH SIDES
FASTEN ALL 3-PLY LVL'S 20"-24" WITH 2 ROWS OF 16DSINKER NAILS @12" OC STAGGERED, FROM BOTH SIDES
FASTEN ALL 4-PLY LVL'S UP TO 18" WITH 2 ROWS OF 1/2" STAGGEREDTHROUGH BOLTS @12" OC STAGGERED
FASTEN ALL 4-PLY LVL'S 20"-24" WITH 3 ROWS OF 1/2" STAGGEREDTHROUGH BOLTS @12" OC STAGGERED
ALL 1/2" BOLTS , CAN BE REPLACEDWITH SDW22634 SCREWS
UNLESS OTHERWISE NOTEDON THE LAYOUT FOR ALL CONNECTION DETAILS
Revision Date:
Revision Date:2NDFLR FRAMINGCarter Lumber, Noblesville INSnellenbergerCarter Noblesville07/21/20
Mike Sheeks