Loading...
HomeMy WebLinkAboutLeVora Entry ProgressFirst Floor 0' - 0" Second Floor 9' - 0" 2 A-1 A-1 7New Ekena Millwork Urethane 12" H Craftsman crosshead (paint) Line of current brick edge is covered with new construction Install smooth face LP SmartSide panel on treated furring over existing brick and removed wood trim New half columns at house per plan. 3/4" LP SmartSide trim (smooth face) New Jeld Wen- Aurora Fiberglass Crafsman AF4-3668-068 door and sidelites. Configuration as selected by Owner First Floor 0' -0" Second Floor 9' -0" 3 A-1 8' - 3"1 A-1 1' - 0" New light fixture as directed by Owner 1/2" reveal at column base w/ sealant --- -5 A-16"10"Soffit and fascia smooth face smarttrim Beam-(2) 2x10 1x6 smarttrim Gabel wall 2x4 @ 16" o.c. Gabel wall facing 1/2" smooth smartside panel both sides Porch ceiling- 1xt&g smart trim First Floor 0' - 0" Second Floor 9' - 0" 2 A-1 7' - 8 1/2" B/Bm7 12 Asphalt shingles (match exist.) on self adhered ice and water barrier 5/8" CDX plywood 2x8 @ 16" o.c. Prefin. drip edge 1x8 smart trim fascia Beam-(2) 2x10 Soffit- smooth face smart siding Porch ceiling-1xt&g smart trim 2 A-1 3 A-1 1 A-1 10' - 0" Exist. Porch 5' - 0"5' - 0"5' - 0" 1' - 0"4' - 0"7' - 10" Exist M.O. +/- 7' - 1" 5' - 10" R.O. 2' - 11" 2' - 11" 1' - 0" 1' - 0" 0' - 8" 8"8"1' - 1" 1' - 1"cL cL1' - 0"cLcL 3 1/2"4 1/2" Ln. of (2) 2x 10 beams above Roof edge above Column treated 6x6 w/ Simpson column baseColumn treated 6x6 w/ Simpson column base A-1 5 3"Edge of exist. brick veneer Edge of exist. brick veneer 8"8" 3 1/2"4 1/2" 1x Column LP Smart Trim below and above 6x6 treated column in Simpson ABU 66Z galv. stand off column base LP Smart Trim column enclosure Furring as req'd1" min 2" min3"1"min. sawcut reglet-insert prefin. counterflash'g in sealant step flash'g min. 3" leg self adhered ice/water barrier min. 6"vertical General Notes: 1. All construction in accordance with Indiana Residentail Code 2005 and ammendments. 2. Design assumes existing foundation and soil bearing capacity of 2,000 psf. 3. Remove existing door and wood trim surround in a timely manner. Prep new door and sidelite for installation prior to demolition. Opening shall not be left open or unprotected overnight or in inclimate weather. 4. New finished construction (other than urethane door crosshead) is to be LP SmartSiding / Trim or similar approved product. Install per manufacturers instructions, seal all cut edges prior to final installation. LeVora New Entry 13918 Woods Edge Ct. Carmel Indiana 46032-8978 1/4" = 1'-0"1 New Door and Trim 1/2" = 1'-0"2 Section at Porch 1/4" = 1'-0"3 Porch 1/4" = 1'-0"4 Porch Plan 10/7/190 1' 2' 4' 0 1' 2' 4'0 1' 2' 4' 0 6" 1' 2' 6 Entry Persp 1" = 1'-0"5 Column Detail 0 3" 6" 1' 1" = 1'-0"7 Roof Flashing 0 3" 6" 1' 07/21/20 Mike Sheeks