Loading...
HomeMy WebLinkAboutM003.016023 Swingley Ridge Rd Chesterfield, MO 63017 314-434-1200 MiTek USA, Inc. Re: The truss drawing(s) referenced below have been prepared by MiTek USA, Inc. under my direct supervision based on the parameters provided by ProBuild (CarterLee Bldg Components). July 6,2020 Liu, Xuegang Pages or sheets covered by this seal: I41920896 thru I41920933 My license renewal date for the state of Indiana is July 31, 2022. TG-143 Pyatt - 143 TG IMPORTANT NOTE: The seal on these truss component designs is a certification that the engineer named is licensed in the jurisdiction(s) identified and that the designs comply with ANSI/TPI 1. These designs are based upon parameters shown (e.g., loads, supports, dimensions, shapes and design codes), which were given to MiTek or TRENCO. Any project specific information included is for MiTek's or TRENCO's customers file reference purpose only, and was not taken into account in the preparation of these designs. MiTek or TRENCO has not independently verified the applicability of the design parameters or the designs for any particular building. Before use, the building designer should verify applicability of design parameters and properly incorporate these designs into the overall building design per ANSI/TPI 1, Chapter 2. 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job TG-143 Truss BP01 Truss Type Flat Qty 1 Ply 1 Pyatt - 143 TG Job Reference (optional) I41920896 8.240 s Mar 9 2020 MiTek Industries, Inc. Mon Jul 6 14:08:13 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:p21FHLh8zPRQybDyxoj12cyVs?P-NZJ8XiRmmHnbZh4QD8tF92cOpaG3F7WxgsNOifz_mFW Scale = 1:10.9 1 2 4 3 5 6 3x4 3x4 6x6 3x4 3x4 1-3-12 1-3-12 1-3-12 1-3-12 1-7-20-7-41-7-2LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.03 0.01 0.01 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 -0.00 -0.00 (loc) 4 4 6 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 5 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 1-3-12 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)4=Mechanical, 6=0-3-4 Max Horz 4=-28(LC 10) Max Uplift 4=-13(LC 8), 6=-13(LC 9) Max Grav 4=40(LC 1), 6=28(LC 17) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Corner(3) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Provide adequate drainage to prevent water ponding. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Bearing at joint(s) 6 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 13 lb uplift at joint 4 and 13 lb uplift at joint 6. 8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. July 6,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job TG-143 Truss BP02 Truss Type FLAT Qty 1 Ply 1 Pyatt - 143 TG Job Reference (optional) I41920897 8.240 s Mar 9 2020 MiTek Industries, Inc. Mon Jul 6 14:08:14 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:p21FHLh8zPRQybDyxoj12cyVs?P-rltWl2SOXavSArfcnsOUhG9Yg_c2_a_5vW6xE5z_mFV Scale = 1:10.9 1 2 4 3 3x4 3x4 3x4 3x4 1-10-8 1-10-8 0-1-8 0-1-8 1-10-8 1-9-0 1-3-101-7-2LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.09 0.03 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 -0.00 0.00 (loc) 4 4 3 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 6 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 1-10-8 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)4=Mechanical, 3=Mechanical Max Horz 4=-33(LC 8) Max Grav 4=157(LC 18), 3=157(LC 17) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Corner(3) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Provide adequate drainage to prevent water ponding. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Load case(s) 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22 has/have been modified. Building designer must review loads to verify that they are correct for the intended use of this truss. LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 3-4=-20, 1-2=-175 2) Dead + 0.75 Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 3-4=-20, 1-2=-165 3) Dead + Uninhabitable Attic Without Storage: Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 3-4=-40, 1-2=-135 4) Dead + 0.6 C-C Wind (Pos. Internal) Case 1: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 3-4=-12, 1-2=-49 Horz: 1-4=19, 2-3=29 5) Dead + 0.6 C-C Wind (Pos. Internal) Case 2: Lumber Increase=1.60, Plate Increase=1.60 Continued on page 2 July 6,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job TG-143 Truss BP02 Truss Type FLAT Qty 1 Ply 1 Pyatt - 143 TG Job Reference (optional) I41920897 8.240 s Mar 9 2020 MiTek Industries, Inc. Mon Jul 6 14:08:14 2020 Page 2 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:p21FHLh8zPRQybDyxoj12cyVs?P-rltWl2SOXavSArfcnsOUhG9Yg_c2_a_5vW6xE5z_mFV LOAD CASE(S) Standard Uniform Loads (plf) Vert: 3-4=-12, 1-2=-49 Horz: 1-4=-29, 2-3=-19 6) Dead + 0.6 C-C Wind (Neg. Internal) Case 1: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 3-4=-20, 1-2=-146 Horz: 1-4=-21, 2-3=-27 7) Dead + 0.6 C-C Wind (Neg. Internal) Case 2: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 3-4=-20, 1-2=-146 Horz: 1-4=27, 2-3=21 8) Dead + 0.6 MWFRS Wind (Pos. Internal) Left: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 3-4=-12, 1-2=-97 Horz: 1-4=11, 2-3=14 9) Dead + 0.6 MWFRS Wind (Pos. Internal) Right: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 3-4=-12, 1-2=-97 Horz: 1-4=-14, 2-3=-11 10) Dead + 0.6 MWFRS Wind (Neg. Internal) Left: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 3-4=-20, 1-2=-136 Horz: 1-4=20, 2-3=6 11) Dead + 0.6 MWFRS Wind (Neg. Internal) Right: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 3-4=-20, 1-2=-136 Horz: 1-4=-6, 2-3=-20 12) Dead + 0.6 MWFRS Wind (Pos. Internal) 1st Parallel: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 3-4=-12, 1-2=-104 Horz: 1-4=-18, 2-3=18 13) Dead + 0.6 MWFRS Wind (Pos. Internal) 2nd Parallel: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 3-4=-12, 1-2=-113 Horz: 1-4=-18, 2-3=18 14) Dead + 0.6 MWFRS Wind (Neg. Internal) 1st Parallel: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 3-4=-20, 1-2=-136 Horz: 1-4=-10, 2-3=10 15) Dead + 0.6 MWFRS Wind (Neg. Internal) 2nd Parallel: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 3-4=-20, 1-2=-136 Horz: 1-4=-10, 2-3=10 16) Dead: Lumber Increase=0.90, Plate Increase=0.90 Plt. metal=0.90 Uniform Loads (plf) Vert: 3-4=-20, 1-2=-135 17) Dead + 0.75 Roof Live (bal.) + 0.75(0.6 MWFRS Wind (Neg. Int) Left): Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 3-4=-20, 1-2=-165 Horz: 1-4=15, 2-3=4 18) Dead + 0.75 Roof Live (bal.) + 0.75(0.6 MWFRS Wind (Neg. Int) Right): Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 3-4=-20, 1-2=-165 Horz: 1-4=-4, 2-3=-15 19) Dead + 0.75 Roof Live (bal.) + 0.75(0.6 MWFRS Wind (Neg. Int) 1st Parallel): Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 3-4=-20, 1-2=-165 Horz: 1-4=-7, 2-3=7 20) Dead + 0.75 Roof Live (bal.) + 0.75(0.6 MWFRS Wind (Neg. Int) 2nd Parallel): Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 3-4=-20, 1-2=-165 Horz: 1-4=-7, 2-3=7 21) Dead + 0.6 C-C Wind Min. Down: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 3-4=-12, 1-2=-143 Horz: 1-4=-16, 2-3=-16 22) Dead + 0.6 C-C Wind Min. Upward: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 3-4=-12, 1-2=-111 Horz: 1-4=16, 2-3=16 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job TG-143 Truss BP03 Truss Type FLAT Qty 4 Ply 1 Pyatt - 143 TG Job Reference (optional) I41920898 8.240 s Mar 9 2020 MiTek Industries, Inc. Mon Jul 6 14:08:15 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:p21FHLh8zPRQybDyxoj12cyVs?P-KyRuyOS0Iu1Jo?EoLZvjEThjQOyHj1EE7AsVmYz_mFU Scale = 1:10.9 1 2 4 3 3x4 3x4 3x4 3x4 1-10-8 1-10-8 1-10-8 1-10-8 1-7-2LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.09 0.03 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 -0.00 0.00 (loc) 4 4 3 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 6 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 1-10-8 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)4=Mechanical, 3=Mechanical Max Horz 4=-33(LC 8) Max Grav 4=157(LC 18), 3=157(LC 17) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Corner(3) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Provide adequate drainage to prevent water ponding. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Load case(s) 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22 has/have been modified. Building designer must review loads to verify that they are correct for the intended use of this truss. LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 3-4=-20, 1-2=-175 2) Dead + 0.75 Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 3-4=-20, 1-2=-165 3) Dead + Uninhabitable Attic Without Storage: Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 3-4=-40, 1-2=-135 4) Dead + 0.6 C-C Wind (Pos. Internal) Case 1: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 3-4=-12, 1-2=-49 Horz: 1-4=19, 2-3=29 5) Dead + 0.6 C-C Wind (Pos. Internal) Case 2: Lumber Increase=1.60, Plate Increase=1.60 Continued on page 2 July 6,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job TG-143 Truss BP03 Truss Type FLAT Qty 4 Ply 1 Pyatt - 143 TG Job Reference (optional) I41920898 8.240 s Mar 9 2020 MiTek Industries, Inc. Mon Jul 6 14:08:15 2020 Page 2 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:p21FHLh8zPRQybDyxoj12cyVs?P-KyRuyOS0Iu1Jo?EoLZvjEThjQOyHj1EE7AsVmYz_mFU LOAD CASE(S) Standard Uniform Loads (plf) Vert: 3-4=-12, 1-2=-49 Horz: 1-4=-29, 2-3=-19 6) Dead + 0.6 C-C Wind (Neg. Internal) Case 1: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 3-4=-20, 1-2=-146 Horz: 1-4=-21, 2-3=-27 7) Dead + 0.6 C-C Wind (Neg. Internal) Case 2: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 3-4=-20, 1-2=-146 Horz: 1-4=27, 2-3=21 8) Dead + 0.6 MWFRS Wind (Pos. Internal) Left: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 3-4=-12, 1-2=-97 Horz: 1-4=11, 2-3=14 9) Dead + 0.6 MWFRS Wind (Pos. Internal) Right: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 3-4=-12, 1-2=-97 Horz: 1-4=-14, 2-3=-11 10) Dead + 0.6 MWFRS Wind (Neg. Internal) Left: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 3-4=-20, 1-2=-136 Horz: 1-4=20, 2-3=6 11) Dead + 0.6 MWFRS Wind (Neg. Internal) Right: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 3-4=-20, 1-2=-136 Horz: 1-4=-6, 2-3=-20 12) Dead + 0.6 MWFRS Wind (Pos. Internal) 1st Parallel: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 3-4=-12, 1-2=-104 Horz: 1-4=-18, 2-3=18 13) Dead + 0.6 MWFRS Wind (Pos. Internal) 2nd Parallel: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 3-4=-12, 1-2=-113 Horz: 1-4=-18, 2-3=18 14) Dead + 0.6 MWFRS Wind (Neg. Internal) 1st Parallel: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 3-4=-20, 1-2=-136 Horz: 1-4=-10, 2-3=10 15) Dead + 0.6 MWFRS Wind (Neg. Internal) 2nd Parallel: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 3-4=-20, 1-2=-136 Horz: 1-4=-10, 2-3=10 16) Dead: Lumber Increase=0.90, Plate Increase=0.90 Plt. metal=0.90 Uniform Loads (plf) Vert: 3-4=-20, 1-2=-135 17) Dead + 0.75 Roof Live (bal.) + 0.75(0.6 MWFRS Wind (Neg. Int) Left): Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 3-4=-20, 1-2=-165 Horz: 1-4=15, 2-3=4 18) Dead + 0.75 Roof Live (bal.) + 0.75(0.6 MWFRS Wind (Neg. Int) Right): Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 3-4=-20, 1-2=-165 Horz: 1-4=-4, 2-3=-15 19) Dead + 0.75 Roof Live (bal.) + 0.75(0.6 MWFRS Wind (Neg. Int) 1st Parallel): Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 3-4=-20, 1-2=-165 Horz: 1-4=-7, 2-3=7 20) Dead + 0.75 Roof Live (bal.) + 0.75(0.6 MWFRS Wind (Neg. Int) 2nd Parallel): Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 3-4=-20, 1-2=-165 Horz: 1-4=-7, 2-3=7 21) Dead + 0.6 C-C Wind Min. Down: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 3-4=-12, 1-2=-143 Horz: 1-4=-16, 2-3=-16 22) Dead + 0.6 C-C Wind Min. Upward: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 3-4=-12, 1-2=-111 Horz: 1-4=16, 2-3=16 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job TG-143 Truss CG01 Truss Type Diagonal Hip Girder Qty 1 Ply 1 Pyatt - 143 TG Job Reference (optional) I41920899 8.240 s Mar 9 2020 MiTek Industries, Inc. Mon Jul 6 14:08:16 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:p21FHLh8zPRQybDyxoj12cyVs?P-o8?GAjTe3CAAQ9p?uHRynhEs3oGbSUUOMqb2J_z_mFT Scale = 1:15.2 1 2 5 6 7 3 8 9 4 3x8 4-3-12 4-3-4 -1-8-0 1-8-0 4-3-12 4-3-12 0-9-02-5-114.80 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.22 0.15 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.01 -0.03 0.01 (loc) 4-5 4-5 3 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 13 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 4-3-12 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)5=0-4-13, 3=Mechanical, 4=Mechanical Max Horz 5=71(LC 8) Max Uplift 5=-46(LC 8), 3=-30(LC 8) Max Grav 5=279(LC 1), 3=92(LC 1), 4=74(LC 3) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 46 lb uplift at joint 5 and 30 lb uplift at joint 3. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 24 lb down and 77 lb up at 1-9-9, and 48 lb down and 38 lb up at 3-2-0 on top chord, and 3 lb down and 7 lb up at 1-9-9, and 12 lb down at 3-2-0 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 8) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-2=-60, 2-3=-60, 4-5=-20 Concentrated Loads (lb) Vert: 6=25(B) 8=5(B) 9=-1(F) July 6,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job TG-143 Truss CG02 Truss Type Diagonal Hip Girder Qty 1 Ply 1 Pyatt - 143 TG Job Reference (optional) I41920900 8.240 s Mar 9 2020 MiTek Industries, Inc. Mon Jul 6 14:08:16 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:p21FHLh8zPRQybDyxoj12cyVs?P-o8?GAjTe3CAAQ9p?uHRynhEqHoG8STwOMqb2J_z_mFT Scale = 1:14.5 1 2 5 6 7 8 3 9 4 3x4 4x8 -1-7-7 1-7-7 4-9-12 4-9-12 1-1-00-7-142-4-20-7-42-0-22-4-23.15 12 Plate Offsets (X,Y)-- [2:0-3-1,0-1-11] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.33 0.18 0.10 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.02 -0.04 -0.01 (loc) 4-5 4-5 4 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 14 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud OTHERS 2x6 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 4-9-12 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)3=Mechanical, 4=Mechanical, 7=0-1-14 Max Horz 7=53(LC 8) Max Uplift 3=-28(LC 4), 7=-66(LC 4) Max Grav 3=106(LC 1), 4=80(LC 3), 7=280(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Bearing at joint(s) 7 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 6) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 7. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 28 lb uplift at joint 3 and 66 lb uplift at joint 7. 8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 25 lb down and 79 lb up at 2-3-1, and 12 lb down and 18 lb up at 2-4-1 on top chord, and 5 lb down and 11 lb up at 2-3-1, and 2 lb down and 2 lb up at 2-4-1 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 10) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-2=-60, 2-3=-60, 4-5=-20 Concentrated Loads (lb) Vert: 8=26(B) 9=6(F=2, B=4) July 6,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job TG-143 Truss GE01 Truss Type GABLE Qty 1 Ply 1 Pyatt - 143 TG Job Reference (optional) I41920901 8.240 s Mar 9 2020 MiTek Industries, Inc. Mon Jul 6 14:08:18 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:p21FHLh8zPRQybDyxoj12cyVs?P-kX61bPVvbpQufTzN0iTQs6JF7bz5wOFhq849Ntz_mFR Scale = 1:39.4 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 30 29 28 27 26 25 24 23 22 21 20 19 18 4x6 3x4 3x8 5x6 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 3x4 3x8 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 19-10-0 19-10-0 -1-0-0 1-0-0 9-11-0 9-11-0 19-10-0 9-11-0 20-10-0 1-0-0 0-6-125-6-40-6-126.00 12 Plate Offsets (X,Y)-- [2:0-0-0,0-1-3], [2:0-2-13,Edge], [16:0-2-13,Edge], [16:Edge,0-1-3], [24:0-3-0,0-3-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.06 0.02 0.05 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 -0.00 0.00 (loc) 17 17 16 l/defl n/r n/r n/a L/d 120 120 n/a PLATES MT20 Weight: 88 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF-S Stud WEDGE Left: 2x4 SPF-S Stud, Right: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 19-10-0. (lb) - Max Horz 2=71(LC 11) Max Uplift All uplift 100 lb or less at joint(s) 2, 26, 27, 28, 29, 16, 30, 22, 21, 20, 19, 18 Max Grav All reactions 250 lb or less at joint(s) 2, 24, 25, 26, 27, 28, 29, 16, 30, 23, 22, 21, 20, 19, 18 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=2ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Corner(3E) -1-0-0 to 1-11-0, Exterior(2N) 1-11-0 to 9-11-0, Corner(3R) 9-11-0 to 12-11-0, Exterior(2N) 12-11-0 to 20-10-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Gable requires continuous bottom chord bearing. 5) Gable studs spaced at 1-4-0 oc. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 26, 27, 28, 29, 16, 30, 22, 21, 20, 19, 18. 9) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. July 6,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job TG-143 Truss GE02 Truss Type GABLE Qty 1 Ply 1 Pyatt - 143 TG Job Reference (optional) I41920902 8.240 s Mar 9 2020 MiTek Industries, Inc. Mon Jul 6 14:08:20 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:p21FHLh8zPRQybDyxoj12cyVs?P-gvEn?5W97Qgcum7m76VuxXPZWPesOHIzHSZGSlz_mFP Scale = 1:46.0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 30 29 28 27 26 25 24 23 22 21 20 19 18 17 31 32 33 34 35 36 41 42 43 3x4 3x6 4x6 4x10 3x6 4x8 3x6 3x4 2x4 2x4 3x8 2x4 2x4 3x8 2x4 2x4 3x8 2x4 2x4 2x4 2x4 5x12 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 3-7-12 3-7-12 6-10-12 3-3-0 17-10-12 11-0-0 6-10-12 6-10-12 8-10-12 2-0-0 17-10-12 9-0-0 18-10-12 1-0-0 5-5-06-9-00-9-05-5-08.00 12 Plate Offsets (X,Y)-- [15:0-3-5,0-0-3] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-MS 0.19 0.07 0.08 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 -0.01 0.00 (loc) 28 28 15 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 121 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud OTHERS 2x4 SPF-S Stud SLIDER Right 2x4 SPF-S Stud 1-11-0 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 1-6. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. JOINTS 1 Brace at Jt(s): 1, 31, 33, 36 REACTIONS.All bearings 14-3-0 except (jt=length) 30=Mechanical. (lb) - Max Horz 30=-165(LC 10) Max Uplift All uplift 100 lb or less at joint(s) 30, 25, 27, 26, 24, 21, 20, 19, 18, 17 Max Grav All reactions 250 lb or less at joint(s) 30, 25, 15, 26, 24, 22, 21, 20, 19, 18, 17, 15 except 27=259(LC 23), 27=259(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) 0-1-12 to 3-1-12, Interior(1) 3-1-12 to 8-10-12, Exterior(2R) 8-10-12 to 11-10-12, Interior(1) 11-10-12 to 18-10-12 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Provide adequate drainage to prevent water ponding. 5) Gable studs spaced at 1-4-0 oc. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Refer to girder(s) for truss to truss connections. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 30, 25, 27, 26, 24, 21, 20, 19, 18, 17. 10) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 11) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. July 6,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job TG-143 Truss GE02A Truss Type GABLE Qty 1 Ply 1 Pyatt - 143 TG Job Reference (optional) I41920903 8.240 s Mar 9 2020 MiTek Industries, Inc. Mon Jul 6 14:08:22 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:p21FHLh8zPRQybDyxoj12cyVs?P-cIMXQnYPe2wJ84G9FXXM0yUuZCDLs_jGkm2NWez_mFN Scale = 1:46.1 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 22 21 20 19 18 17 16 25 23 24 34 35 36 37 3x8 3x4 3x6 4x6 3x6 3x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 9-0-0 9-0-0 9-4-0 0-4-0 18-0-0 8-8-0 -1-0-0 1-0-0 9-0-0 9-0-0 18-0-0 9-0-0 19-0-0 1-0-0 0-9-06-9-00-9-08.00 12 Plate Offsets (X,Y)-- [2:0-3-8,Edge], [14:0-3-5,0-0-7] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-MS 0.22 0.51 0.85 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.11 -0.22 0.02 (loc) 22-28 22-28 2 l/defl >999 >481 n/a L/d 240 180 n/a PLATES MT20 Weight: 85 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud OTHERS 2x4 SPF-S Stud SLIDER Left 2x4 SPF-S Stud 1-11-0, Right 2x4 SPF-S Stud 1-11-0 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. JOINTS 1 Brace at Jt(s): 23 REACTIONS.All bearings 8-11-8 except (jt=length) 2=0-3-8, 22=0-3-8, 22=0-3-8. (lb) - Max Horz 2=104(LC 11) Max Uplift All uplift 100 lb or less at joint(s) 2, 18, 17, 16 except 20=-261(LC 3) Max Grav All reactions 250 lb or less at joint(s) 19, 18, 17, 16 except 2=530(LC 1), 14=318(LC 1), 22=374(LC 1), 22=374(LC 1), 14=318(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-4=-580/65, 8-9=-252/80, 10-11=-252/30, 11-12=-251/8, 12-14=-263/0 BOT CHORD 2-22=0/381 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 9-0-0, Exterior(2R) 9-0-0 to 12-0-0 , Interior(1) 12-0-0 to 19-0-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Gable studs spaced at 1-4-0 oc. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 18, 17, 16 except (jt=lb) 20=261. 8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. July 6,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job TG-143 Truss GE03 Truss Type GABLE Qty 1 Ply 1 Pyatt - 143 TG Job Reference (optional) I41920904 8.240 s Mar 9 2020 MiTek Industries, Inc. Mon Jul 6 14:08:23 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:p21FHLh8zPRQybDyxoj12cyVs?P-5Uwwe7Z1PL2AlErLpF3bZ9152chGbeiQzQow34z_mFM Scale = 1:25.7 1 2 3 4 5 6 7 8 9 16 15 14 13 12 11 10 3x6 4x6 3x6 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 9-4-0 9-4-0 -1-0-0 1-0-0 4-8-0 4-8-0 9-4-0 4-8-0 10-4-0 1-0-0 0-9-03-10-50-9-08.00 12 Plate Offsets (X,Y)-- [2:0-1-3,0-1-12], [8:0-1-3,0-1-12], [10:0-0-0,0-1-12], [10:Edge,0-3-8], [16:0-0-0,0-1-12] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.11 0.02 0.03 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 -0.00 0.00 (loc) 9 9 10 l/defl n/r n/r n/a L/d 120 120 n/a PLATES MT20 Weight: 38 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. REACTIONS.All bearings 9-4-0. (lb) - Max Horz 16=-72(LC 10) Max Uplift All uplift 100 lb or less at joint(s) 16, 10, 14, 15, 12, 11 Max Grav All reactions 250 lb or less at joint(s) 16, 10, 13, 14, 15, 12, 11 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=2ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Corner(3E) -1-0-0 to 2-0-0, Exterior(2N) 2-0-0 to 4-8-0, Corner(3R) 4-8-0 to 7-8-0, Exterior(2N) 7-8-0 to 10-4-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Gable requires continuous bottom chord bearing. 5) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 6) Gable studs spaced at 1-4-0 oc. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 16, 10, 14, 15, 12, 11. 10) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. July 6,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job TG-143 Truss GE04 Truss Type GABLE Qty 1 Ply 1 Pyatt - 143 TG Job Reference (optional) I41920905 8.240 s Mar 9 2020 MiTek Industries, Inc. Mon Jul 6 14:08:24 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:p21FHLh8zPRQybDyxoj12cyVs?P-ZgUIrSZgAfA1NOQXMyaq5NZDj0?lK5lZC4YTbWz_mFL Scale = 1:34.4 1 2 3 4 5 6 7 8 9 16 15 14 13 12 11 10 17 3x4 3x4 3x4 3x6 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 -1-0-0 1-0-0 9-11-8 9-11-8 0-6-125-6-86.00 12 Plate Offsets (X,Y)-- [2:0-0-0,0-1-3], [2:0-1-5,0-4-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.24 0.07 0.05 DEFL. Vert(LL) Vert(CT) Horz(CT) in 0.00 -0.00 0.00 (loc) 1 1 10 l/defl n/r n/r n/a L/d 120 120 n/a PLATES MT20 Weight: 46 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud OTHERS 2x4 SPF-S Stud WEDGE Left: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 9-11-8. (lb) - Max Horz 2=144(LC 9) Max Uplift All uplift 100 lb or less at joint(s) 10, 11, 12, 13, 14, 15, 16 Max Grav All reactions 250 lb or less at joint(s) 10, 2, 11, 12, 13, 14, 15, 16 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-320/164, 3-4=-250/135 NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=2ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Corner(3E) -1-0-0 to 1-11-8, Exterior(2N) 1-11-8 to 9-9-12 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) Gable requires continuous bottom chord bearing. 4) Gable studs spaced at 1-4-0 oc. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 10, 11, 12, 13, 14, 15, 16. 8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. July 6,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job TG-143 Truss GE05 Truss Type GABLE Qty 1 Ply 1 Pyatt - 143 TG Job Reference (optional) I41920906 8.240 s Mar 9 2020 MiTek Industries, Inc. Mon Jul 6 14:08:25 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:p21FHLh8zPRQybDyxoj12cyVs?P-1t1g3oaIxzIu?Y?jwg53ea6QlQLz3XQiRkH17zz_mFK Scale = 1:15.2 1 2 3 4 5 8 7 6 3x4 3x4 3x4 2x4 2x4 2x4 2x4 -1-0-0 1-0-0 5-11-8 5-11-8 0-4-82-4-54.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.09 0.07 0.08 DEFL. Vert(LL) Vert(CT) Horz(CT) in 0.00 0.00 0.00 (loc) 1 1 6 l/defl n/r n/r n/a L/d 120 120 n/a PLATES MT20 Weight: 19 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 5-11-8 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 5-11-8. (lb) - Max Horz 2=58(LC 11) Max Uplift All uplift 100 lb or less at joint(s) 2, 7 Max Grav All reactions 250 lb or less at joint(s) 6, 2, 7 except 8=251(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=2ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Corner(3E) -1-0-0 to 2-0-0, Exterior(2N) 2-0-0 to 5-9-12 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) Gable requires continuous bottom chord bearing. 4) Gable studs spaced at 1-4-0 oc. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 7. 8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. July 6,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job TG-143 Truss GE06 Truss Type GABLE Qty 1 Ply 1 Pyatt - 143 TG Job Reference (optional) I41920907 8.240 s Mar 9 2020 MiTek Industries, Inc. Mon Jul 6 14:08:25 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:p21FHLh8zPRQybDyxoj12cyVs?P-1t1g3oaIxzIu?Y?jwg53ea6RMQMY3XeiRkH17zz_mFK Scale = 1:12.9 1 2 3 4 6 5 7 3x4 3x4 3x4 2x4 2x4 -1-0-0 1-0-0 3-7-8 3-7-8 0-5-122-0-45.10 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.06 0.03 0.07 DEFL. Vert(LL) Vert(CT) Horz(CT) in 0.00 -0.00 0.00 (loc) 1 1 5 l/defl n/r n/r n/a L/d 120 120 n/a PLATES MT20 Weight: 12 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 3-7-8 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)5=3-7-8, 2=3-7-8, 6=3-7-8 Max Horz 2=48(LC 9) Max Uplift 5=-3(LC 9), 2=-22(LC 12) Max Grav 5=23(LC 1), 2=152(LC 1), 6=163(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=2ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Corner(3E) -1-0-0 to 2-3-8, Exterior(2N) 2-3-8 to 3-5-12 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) Gable requires continuous bottom chord bearing. 4) Gable studs spaced at 1-4-0 oc. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 2. 8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. July 6,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job TG-143 Truss J01 Truss Type Jack-Open Qty 2 Ply 1 Pyatt - 143 TG Job Reference (optional) I41920908 8.240 s Mar 9 2020 MiTek Industries, Inc. Mon Jul 6 14:08:26 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:p21FHLh8zPRQybDyxoj12cyVs?P-V3b2G8bwiGQlchawUNcIBofZiqhMo?ysfN1afPz_mFJ Scale = 1:19.9 1 2 5 6 7 3 4 3x6 3-11-4 3-11-4 -1-0-0 1-0-0 3-11-4 3-11-4 0-9-03-4-82-11-53-4-88.00 12 Plate Offsets (X,Y)-- [2:0-1-3,0-1-12], [5:0-0-0,0-1-12] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.21 0.12 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.01 -0.02 0.01 (loc) 4-5 4-5 3 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 12 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 3-11-4 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)5=0-3-8, 3=Mechanical, 4=Mechanical Max Horz 5=91(LC 12) Max Uplift 3=-34(LC 12) Max Grav 5=228(LC 1), 3=97(LC 1), 4=70(LC 3) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 3-10-8 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. July 6,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job TG-143 Truss J02 Truss Type Jack-Open Qty 1 Ply 1 Pyatt - 143 TG Job Reference (optional) I41920909 8.240 s Mar 9 2020 MiTek Industries, Inc. Mon Jul 6 14:08:27 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:p21FHLh8zPRQybDyxoj12cyVs?P-zF9QTUcYTaYcEr96247Xj?BmwD2FXSC?u1m7Crz_mFI Scale = 1:10.4 1 2 5 3 4 3x6 1-1-8 1-1-8 -1-0-0 1-0-0 1-1-8 1-1-8 0-9-01-6-01-0-131-6-08.00 12 Plate Offsets (X,Y)-- [2:0-1-3,0-1-12], [5:0-0-0,0-1-12] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.12 0.02 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in 0.00 0.00 -0.00 (loc) 5 5 3 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 5 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 1-1-8 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)5=0-3-8, 3=Mechanical, 4=Mechanical Max Horz 5=50(LC 12) Max Uplift 5=-20(LC 12), 3=-8(LC 9), 4=-1(LC 12) Max Grav 5=148(LC 1), 3=5(LC 10), 4=15(LC 3) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 3, 4. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. July 6,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job TG-143 Truss J03 Truss Type Jack-Open Qty 1 Ply 1 Pyatt - 143 TG Job Reference (optional) I41920910 8.240 s Mar 9 2020 MiTek Industries, Inc. Mon Jul 6 14:08:28 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:p21FHLh8zPRQybDyxoj12cyVs?P-RSjphqcAEugTs?kIboemGDkxAdNaGvS97hWhkIz_mFH Scale = 1:13.3 1 2 5 3 4 3x4 3x6 3-0-4 3-0-4 -1-0-0 1-0-0 3-0-4 3-0-4 0-6-122-0-141-8-32-0-146.00 12 Plate Offsets (X,Y)-- [2:0-0-0,0-1-3], [2:0-1-5,0-4-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.08 0.08 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 -0.01 -0.00 (loc) 2-4 2-4 3 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 9 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEDGE Left: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 3-0-4 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)3=Mechanical, 2=0-3-8, 4=Mechanical Max Horz 2=47(LC 12) Max Uplift 3=-21(LC 12), 2=-17(LC 12) Max Grav 3=70(LC 1), 2=195(LC 1), 4=56(LC 3) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 2-11-8 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3, 2. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. July 6,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job TG-143 Truss J04 Truss Type Jack-Open Qty 1 Ply 1 Pyatt - 143 TG Job Reference (optional) I41920911 8.240 s Mar 9 2020 MiTek Industries, Inc. Mon Jul 6 14:08:29 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:p21FHLh8zPRQybDyxoj12cyVs?P-veHBuAdo?BoKT9JV9VA?oQH571kU?MiILLFEGkz_mFG Scale = 1:11.4 1 2 5 3 4 3x4 3x4 -1-1-14 1-1-14 1-3-7 1-3-7 0-10-50-7-141-8-60-3-80-4-71-3-151-8-55.10 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.13 0.03 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in 0.00 -0.00 -0.00 (loc) 5 5 3 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 5 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 1-3-7 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)3=Mechanical, 4=Mechanical, 5=0-1-8 Max Horz 5=46(LC 12) Max Uplift 3=-10(LC 9), 4=-6(LC 12), 5=-16(LC 12) Max Grav 3=5(LC 10), 4=19(LC 3), 5=168(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Corner(3) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Bearing at joint(s) 5 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 6) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 5. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3, 4, 5. 8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. July 6,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job TG-143 Truss J05 Truss Type JACK-OPEN Qty 1 Ply 1 Pyatt - 143 TG Job Reference (optional) I41920912 8.240 s Mar 9 2020 MiTek Industries, Inc. Mon Jul 6 14:08:34 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:p21FHLh8zPRQybDyxoj12cyVs?P-Gc44xthxqkRcawBSy3lAVU_z82Rcgdx1Vdz?xxz_mFB Scale = 1:11.6 1 2 5 3 4 3x4 3x4 -1-1-14 1-1-14 2-1-3 2-1-3 0-8-140-7-121-8-120-3-81-4-91-8-124.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.12 0.04 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 -0.00 -0.00 (loc) 5 4-5 3 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 7 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 2-1-3 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)5=0-1-8, 3=Mechanical, 4=Mechanical Max Horz 5=43(LC 12) Max Uplift 5=-22(LC 12), 3=-10(LC 12) Max Grav 5=181(LC 1), 3=35(LC 1), 4=34(LC 3) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Bearing at joint(s) 5 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 6) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 5. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 3. 8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. July 6,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job TG-143 Truss JG01 Truss Type Half Hip Girder Qty 1 Ply 1 Pyatt - 143 TG Job Reference (optional) I41920913 8.240 s Mar 9 2020 MiTek Industries, Inc. Mon Jul 6 14:08:42 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:p21FHLh8zPRQybDyxoj12cyVs?P-18Z5dcnyxBRUX9o?Qku2qAJIiG8_YEwDLtvQDUz_mF3 Scale = 1:15.3 1 2 3 4 6 57 3x4 3x4 3x4 3x6 3-11-4 3-11-4 -1-0-0 1-0-0 3-11-4 3-11-4 0-9-02-5-148.00 12 Plate Offsets (X,Y)-- [2:0-1-3,0-1-12], [3:0-2-0,0-2-3], [6:0-0-0,0-1-12] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.21 0.13 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.01 -0.02 -0.00 (loc) 5-6 5-6 5 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 13 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 3-11-4 oc purlins, except end verticals, and 2-0-0 oc purlins: 3-4. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)5=Mechanical, 6=0-3-8 Max Horz 6=68(LC 5) Max Uplift 5=-24(LC 5), 6=-26(LC 8) Max Grav 5=156(LC 1), 6=236(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) Provide adequate drainage to prevent water ponding. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 6. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 9) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 60 lb down and 52 lb up at 2-7-5 on top chord, and 27 lb down at 2-7-5 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 10) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-2=-60, 2-3=-60, 3-4=-60, 5-6=-20 Concentrated Loads (lb) Vert: 3=-19(F) 7=-12(F) July 6,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job TG-143 Truss JG02 Truss Type HALF HIP GIRDER Qty 1 Ply 1 Pyatt - 143 TG Job Reference (optional) I41920914 8.240 s Mar 9 2020 MiTek Industries, Inc. Mon Jul 6 14:08:46 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:p21FHLh8zPRQybDyxoj12cyVs?P-vvpcT_qT?Qxv0m6mfaz__0U07uWeU2voGVteNFz_mF? Scale = 1:13.2 1 2 3 5 4 6 7 3x4 3x4 3x4 3x4 3-3-14 3-3-14 -1-1-14 1-1-14 3-2-6 3-2-6 3-3-14 0-1-8 0-10-50-7-142-4-40-3-82-0-120-3-82-4-45.10 12 Plate Offsets (X,Y)-- [4:Edge,0-2-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.12 0.08 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 -0.01 -0.00 (loc) 4-5 4-5 4 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 12 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 3-3-14 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)4=0-1-8, 5=0-1-8 Max Horz 5=65(LC 5) Max Uplift 4=-20(LC 5), 5=-26(LC 8) Max Grav 4=183(LC 1), 5=226(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Bearing at joint(s) 4, 5 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 5) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 4, 5. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4, 5. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 58 lb down and 46 lb up at 2-10-0 on top chord, and 48 lb down at 2-10-0 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 9) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-2=-60, 2-3=-60, 4-5=-20 Concentrated Loads (lb) Vert: 6=-58(F) 7=-30(F) July 6,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job TG-143 Truss M01 Truss Type Monopitch Qty 10 Ply 1 Pyatt - 143 TG Job Reference (optional) I41920915 8.240 s Mar 9 2020 MiTek Industries, Inc. Mon Jul 6 14:08:49 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:p21FHLh8zPRQybDyxoj12cyVs?P-KUUl50tLILKUtErLKiWice6YG5ZshPfFyT5Iyaz_mEy Scale = 1:7.6 1 2 3 4 6x6 0-9-8 0-9-8 -1-0-0 1-0-0 0-9-8 0-9-8 0-6-120-11-80-8-00-3-80-11-86.00 12 Plate Offsets (X,Y)-- [2:0-0-12,0-0-0], [3:0-2-15,0-3-4], [3:0-1-15,0-0-0], [4:0-0-14,0-0-7] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.06 0.05 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 -0.00 -0.00 (loc) 2 2 3 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 4 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 0-9-8 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)3=0-1-8, 2=0-3-8 Max Horz 2=19(LC 9) Max Uplift 3=-27(LC 1), 2=-42(LC 12) Max Grav 3=20(LC 12), 2=138(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Bearing at joint(s) 3 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 5) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 3. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3, 2. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Gap between inside of top chord bearing and first diagonal or vertical web shall not exceed 0.500in. July 6,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job TG-143 Truss M02 Truss Type MONOPITCH Qty 4 Ply 1 Pyatt - 143 TG Job Reference (optional) I41920916 8.240 s Mar 9 2020 MiTek Industries, Inc. Mon Jul 6 14:08:51 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:hUHtOsdVD3hxCU?tdf3IKNyLzHR-GtcVWhucpyaC6X_jS7ZAh3BtevEt9J8XPmaP1Sz_mEw Scale = 1:10.8 2 41 3 3x4 -1-0-0 1-10-0 -1-0-0 1-0-0 0-8-8 0-8-8 0-10-0 0-1-8 0-4-30-11-20-7-120-5-30-5-140-11-28.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.07 0.02 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 -0.00 -0.00 (loc) 2 2 3 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 4 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 0-10-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=Mechanical, 3=0-1-8 Max Horz 1=26(LC 12) Max Uplift 3=-8(LC 12) Max Grav 1=73(LC 1), 3=69(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 3. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3. 7) Beveled plate or shim required to provide full bearing surface with truss chord at joint(s) 3. 8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. VERTICAL SUPPORT OF FREE END OF CHORD IS REQUIRED. July 6,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job TG-143 Truss T01 Truss Type Common Qty 8 Ply 1 Pyatt - 143 TG Job Reference (optional) I41920917 8.240 s Mar 9 2020 MiTek Industries, Inc. Mon Jul 6 14:08:55 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:p21FHLh8zPRQybDyxoj12cyVs?P-9er0M3x6tA4eb9IUhzd6svLV?WPM5277KOYcADz_mEs Scale = 1:36.8 1 2 3 4 5 6 7 8 9 10 11 12 4x6 3x8 5x12 2x4 2x4 3x8 9-11-0 9-11-0 19-10-0 9-11-0 -1-0-0 1-0-0 5-10-10 5-10-10 9-11-0 4-0-6 13-11-6 4-0-6 19-10-0 5-10-10 20-10-0 1-0-0 0-6-125-6-40-6-126.00 12 Plate Offsets (X,Y)-- [2:0-0-5,0-0-11], [2:0-0-11,0-6-0], [2:0-3-8,Edge], [6:0-3-8,Edge], [6:0-0-11,0-6-0], [6:0-0-5,0-0-11], [8:0-6-0,0-3-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.36 0.88 0.32 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.19 -0.41 0.03 (loc) 6-8 6-8 6 l/defl >999 >572 n/a L/d 240 180 n/a PLATES MT20 Weight: 66 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud WEDGE Left: 2x4 SPF-S Stud, Right: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 4-9-6 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)2=0-3-8, 6=0-3-8 Max Horz 2=71(LC 11) Max Uplift 2=-11(LC 12), 6=-11(LC 12) Max Grav 2=850(LC 1), 6=850(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-1206/117, 3-4=-934/92, 4-5=-934/92, 5-6=-1206/117 BOT CHORD 2-8=-39/1007, 6-8=-39/1007 WEBS 4-8=-10/589, 5-8=-308/124, 3-8=-308/124 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 9-11-0, Exterior(2R) 9-11-0 to 12-11-0, Interior(1) 12-11-0 to 20-10-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 6. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. July 6,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job TG-143 Truss T02 Truss Type Common Qty 4 Ply 1 Pyatt - 143 TG Job Reference (optional) I41920918 8.240 s Mar 9 2020 MiTek Industries, Inc. Mon Jul 6 14:08:58 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:p21FHLh8zPRQybDyxoj12cyVs?P-ZDX8_5_?A5SCSc13M5BpUYz2xjV7IQ5Z0MnGnYz_mEp Scale = 1:39.8 1 2 3 4 5 6 7 8 10 9 19 20 21 22 3x8 4x6 3x6 3x8 2x4 4x6 2x4 4x8 3x4 8-10-12 8-10-12 17-10-12 9-0-0 4-7-2 4-7-2 8-10-12 4-3-10 13-3-0 4-4-4 17-10-12 4-7-12 18-10-12 1-0-0 0-9-136-9-00-9-08.00 12 Plate Offsets (X,Y)-- [1:0-3-8,Edge], [7:0-4-13,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-MS 0.19 0.55 0.24 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.09 -0.19 0.02 (loc) 9-17 9-17 7 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 68 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud SLIDER Left 2x6 SPF No.2 1-11-0, Right 2x4 SPF-S Stud 1-11-0 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=Mechanical, 7=0-3-8 Max Horz 1=-101(LC 10) Max Uplift 7=-10(LC 12) Max Grav 1=714(LC 1), 7=778(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-3=-878/47, 3-4=-705/54, 4-5=-707/53, 5-7=-885/46 BOT CHORD 1-9=0/694, 7-9=0/702 WEBS 4-9=0/482 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) 0-0-0 to 3-0-0, Interior(1) 3-0-0 to 8-10-12, Exterior(2R) 8-10-12 to 11-10-12, Interior(1) 11-10-12 to 18-10-12 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 7. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. July 6,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job TG-143 Truss T02A Truss Type Common Qty 7 Ply 1 Pyatt - 143 TG Job Reference (optional) I41920919 8.240 s Mar 9 2020 MiTek Industries, Inc. Mon Jul 6 14:09:00 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:p21FHLh8zPRQybDyxoj12cyVs?P-VcfvPm?FijiwhwASTWDHZz3ORXBOmKYsUgGNrRz_mEn Scale = 1:40.2 1 2 3 4 5 6 7 8 9 11 10 20 21 22 23 4x8 3x4 3x6 4x6 2x4 3x8 2x4 4x8 3x4 9-0-0 9-0-0 18-0-0 9-0-0 -1-0-0 1-0-0 4-7-12 4-7-12 9-0-0 4-4-4 13-4-4 4-4-4 18-0-0 4-7-12 19-0-0 1-0-0 0-9-06-9-00-9-08.00 12 Plate Offsets (X,Y)-- [2:0-3-8,Edge], [8:0-4-13,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-MS 0.19 0.57 0.25 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.09 -0.18 0.02 (loc) 10-18 10-18 8 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 69 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud SLIDER Left 2x4 SPF-S Stud 1-11-0, Right 2x4 SPF-S Stud 1-11-0 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)2=0-3-8, 8=0-3-8 Max Horz 2=104(LC 11) Max Uplift 2=-9(LC 12), 8=-9(LC 12) Max Grav 2=780(LC 1), 8=780(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-4=-889/45, 4-5=-712/52, 5-6=-712/52, 6-8=-889/45 BOT CHORD 2-10=0/705, 8-10=0/705 WEBS 5-10=0/488 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 9-0-0, Exterior(2R) 9-0-0 to 12-0-0 , Interior(1) 12-0-0 to 19-0-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 8. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. July 6,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job TG-143 Truss T02B Truss Type Roof Special Qty 3 Ply 1 Pyatt - 143 TG Job Reference (optional) I41920920 8.240 s Mar 9 2020 MiTek Industries, Inc. Mon Jul 6 14:09:06 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:p21FHLh8zPRQybDyxoj12cyVs?P-Km0Afq40HZT4QrecqnKhoEJOmy8WAtilscji35z_mEh Scale = 1:40.4 1 2 3 4 5 6 7 8 9 10 11 17 16 13 12 15 14 26 27 28 3x6 3x4 5x6 4x8 8x10 3x4 5x6 4x8 3x4 3x12 4x6 5x12 4x8 6x8 2x4 2-1-4 2-1-4 3-11-0 1-9-12 7-3-0 3-4-0 9-0-0 1-9-0 18-0-0 9-0-0 -1-0-0 1-0-0 2-1-4 2-1-4 3-11-0 1-9-12 7-3-0 3-4-0 9-0-0 1-9-0 13-4-4 4-4-4 18-0-0 4-7-12 19-0-0 1-0-0 0-9-06-9-00-9-02-0-08.00 12 Plate Offsets (X,Y)-- [2:0-2-8,0-0-3], [10:0-4-13,Edge], [13:0-3-0,0-3-0], [14:0-3-8,0-2-12], [15:0-6-4,0-3-8], [16:0-3-0,0-3-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-MS 0.26 0.90 0.91 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.12 -0.25 0.19 (loc) 12-24 12-24 10 l/defl >999 >866 n/a L/d 240 180 n/a PLATES MT20 Weight: 90 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 *Except* 5-16,6-13: 2x4 SPF-S Stud WEBS 2x4 SPF-S Stud SLIDER Left 2x4 SPF-S Stud 1-11-0, Right 2x4 SPF-S Stud 1-11-0 BRACING- TOP CHORD Structural wood sheathing directly applied or 3-3-8 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing, Except: 6-0-0 oc bracing: 12-13. 6-0-0 oc bracing: 13-14 10-0-0 oc bracing: 15-16 JOINTS 1 Brace at Jt(s): 14 REACTIONS. (size)2=0-3-8, 10=0-3-8 Max Horz 2=-104(LC 10) Max Uplift 2=-9(LC 12), 10=-9(LC 12) Max Grav 2=780(LC 1), 10=780(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-4=-874/7, 4-5=-2814/0, 5-6=-1176/3, 6-7=-1127/43, 7-8=-710/54, 8-10=-890/47 BOT CHORD 2-17=0/676, 10-12=0/706, 5-15=0/1189, 14-15=0/2421 WEBS 4-17=-823/0, 15-17=0/962, 4-15=0/1658, 5-14=-1513/0, 12-14=0/805, 7-14=0/1165, 7-12=-338/0 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 2-1-4, Interior(1) 2-1-4 to 9-0-0, Exterior(2R) 9-0-0 to 12-0-0 , Interior(1) 12-0-0 to 19-0-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 10. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. DOTTED MEMBERS TO BE REMOVED CONNECTOR PLATES TO BE CUT CLEANLY AND ACCURATELY AND THE REMAINING PLATE MUST BE FULLY EMBEDDED AND UNDISTURBED. July 6,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job TG-143 Truss T02C Truss Type Roof Special Qty 5 Ply 1 Pyatt - 143 TG Job Reference (optional) I41920921 8.240 s Mar 9 2020 MiTek Industries, Inc. Mon Jul 6 14:09:13 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:p21FHLh8zPRQybDyxoj12cyVs?P-d6xp7D9PeiL4lwgyklyKai5WkmdcJBjnTBvZpBz_mEa Scale = 1:40.0 1 2 3 4 5 6 7 8 9 15 14 13 12 11 10 16 17 4x6 3x6 3x4 3x4 3x6 3x12 4x8 3x4 4x8 3x6 3x6 5x12 4x8 3-3-4 3-3-4 6-3-0 2-11-12 9-0-0 2-9-0 16-0-8 7-0-8 18-0-0 1-11-8 -1-0-0 1-0-0 3-3-4 3-3-4 9-0-0 5-8-12 16-0-8 7-0-8 18-0-0 1-11-8 19-0-0 1-0-0 0-9-06-9-00-9-00-5-80-3-88.00 12 Plate Offsets (X,Y)-- [2:0-3-13,0-0-3], [7:0-1-0,0-1-12], [8:0-0-6,0-0-8], [8:0-0-11,0-4-9], [8:Edge,0-1-1], [13:0-6-0,0-4-0], [14:Edge,0-2-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.54 0.56 0.38 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.09 -0.20 0.07 (loc) 11-12 11-12 8 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 82 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 *Except* 5-14: 2x4 SPF-S Stud, 7-10,8-10: 2x6 SPF No.2 WEBS 2x4 SPF-S Stud WEDGE Right: 2x4 SPF-S Stud SLIDER Left 2x4 SPF-S Stud 1-11-4 BRACING- TOP CHORD Structural wood sheathing directly applied or 5-1-3 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 7-12 REACTIONS. (size)2=0-3-8, 8=0-3-8 Max Horz 2=-104(LC 10) Max Uplift 2=-9(LC 12), 8=-13(LC 12) Max Grav 2=774(LC 1), 8=783(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-4=-980/10, 4-5=-983/27, 5-6=-743/50, 6-7=-847/36, 7-8=-998/0 BOT CHORD 2-15=0/715, 12-13=0/791, 11-12=-42/1514, 8-10=0/693 WEBS 13-15=0/681, 5-12=-337/41, 6-12=0/498, 7-12=-925/139 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 9-0-0, Exterior(2R) 9-0-0 to 12-0-0 , Interior(1) 12-0-0 to 19-0-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 8. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. July 6,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job TG-143 Truss T02D Truss Type Roof Special Qty 1 Ply 1 Pyatt - 143 TG Job Reference (optional) I41920922 8.240 s Mar 9 2020 MiTek Industries, Inc. Mon Jul 6 14:09:15 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:p21FHLh8zPRQybDyxoj12cyVs?P-ZU3aYvBfAKbo?DqKsA_og7AsEaI5n5C3wVOgt3z_mEY Scale = 1:43.0 1 2 3 4 5 6 7 8 9 17 16 15 1413 12 11 10 18 19 4x6 3x6 3x4 3x4 3x6 3x12 4x8 3x4 4x8 3x6 3x6 8x16 4x8 3x4 3-3-4 3-3-4 6-3-0 2-11-12 6-8-12 0-5-12 9-0-0 2-3-4 16-0-8 7-0-8 18-0-0 1-11-8 -1-0-0 1-0-0 3-3-4 3-3-4 9-0-0 5-8-12 16-0-8 7-0-8 18-0-0 1-11-8 19-0-0 1-0-0 0-9-06-9-00-9-00-3-88.00 12 Plate Offsets (X,Y)-- [2:0-3-13,0-0-3], [7:0-1-0,0-1-12], [8:0-0-6,0-0-8], [8:0-0-11,0-4-9], [8:Edge,0-1-1], [13:0-2-12,0-0-0], [14:0-8-0,0-0-12] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.54 0.55 0.38 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.09 -0.20 0.07 (loc) 11-12 11-12 8 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 83 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 *Except* 5-16: 2x4 SPF-S Stud, 7-10,8-10: 2x6 SPF No.2 WEBS 2x4 SPF-S Stud *Except* 13-15: 2x6 SPF No.2 WEDGE Right: 2x4 SPF-S Stud SLIDER Left 2x4 SPF-S Stud 1-11-4 BRACING- TOP CHORD Structural wood sheathing directly applied or 5-1-5 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 7-12 REACTIONS. (size)2=0-3-8, 8=0-3-8 Max Horz 2=-104(LC 10) Max Uplift 2=-9(LC 12), 8=-13(LC 12) Max Grav 2=774(LC 1), 8=783(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-4=-969/10, 4-5=-945/32, 5-6=-742/50, 6-7=-846/36, 7-8=-998/0 BOT CHORD 2-17=0/717, 13-14=0/747, 12-13=0/756, 11-12=-42/1515, 8-10=0/693 WEBS 14-17=0/579, 5-12=-291/47, 6-12=0/498, 7-12=-927/139 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 9-0-0, Exterior(2R) 9-0-0 to 12-0-0 , Interior(1) 12-0-0 to 19-0-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 8. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. July 6,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job TG-143 Truss T02E Truss Type Roof Special Qty 1 Ply 1 Pyatt - 143 TG Job Reference (optional) I41920923 8.240 s Mar 9 2020 MiTek Industries, Inc. Mon Jul 6 14:09:18 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:p21FHLh8zPRQybDyxoj12cyVs?P-_3kiAwDXSFzNshYvXIYVHmoNVnJN_RuWdTdKUOz_mEV Scale = 1:41.2 1 2 3 4 5 6 7 8 9 16 15 14 13 12 11 10 17 18 4x6 3x6 3x4 3x4 3x6 3x12 4x8 3x4 4x8 3x6 3x6 5x12 4x8 2x4 3x4 3-3-4 3-3-4 6-3-0 2-11-12 8-8-12 2-5-12 9-0-0 0-3-4 16-0-8 7-0-8 18-0-0 1-11-8 -1-0-0 1-0-0 3-3-4 3-3-4 9-0-0 5-8-12 16-0-8 7-0-8 18-0-0 1-11-8 19-0-0 1-0-0 0-9-06-9-00-9-00-3-88.00 12 Plate Offsets (X,Y)-- [2:0-3-13,0-0-3], [7:0-1-0,0-1-12], [8:0-0-6,0-0-8], [8:0-0-11,0-4-9], [8:Edge,0-1-1], [13:0-6-4,0-4-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.53 0.58 0.38 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.10 -0.23 0.07 (loc) 11-12 11-12 8 l/defl >999 >940 n/a L/d 240 180 n/a PLATES MT20 Weight: 86 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 *Except* 5-15: 2x4 SPF-S Stud, 7-10,8-10: 2x6 SPF No.2 WEBS 2x4 SPF-S Stud *Except* 12-14: 2x6 SPF No.2 WEDGE Right: 2x4 SPF-S Stud SLIDER Left 2x4 SPF-S Stud 1-11-4 BRACING- TOP CHORD Structural wood sheathing directly applied or 5-1-10 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 7-12 REACTIONS. (size)2=0-3-8, 8=0-3-8 Max Horz 2=-104(LC 10) Max Uplift 2=-10(LC 12), 8=-14(LC 12) Max Grav 2=771(LC 1), 8=781(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-4=-977/13, 4-5=-964/30, 5-6=-758/51, 6-7=-833/40, 7-8=-995/0 BOT CHORD 2-16=0/713, 12-13=0/763, 11-12=-40/1512, 8-10=0/690 WEBS 13-16=0/633, 5-12=-312/45, 6-12=0/493, 7-12=-935/135 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 9-0-0, Exterior(2R) 9-0-0 to 12-0-0 , Interior(1) 12-0-0 to 19-0-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 8. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. July 6,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job TG-143 Truss T04 Truss Type MONOPITCH Qty 6 Ply 1 Pyatt - 143 TG Job Reference (optional) I41920924 8.240 s Mar 9 2020 MiTek Industries, Inc. Mon Jul 6 14:09:21 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:p21FHLh8zPRQybDyxoj12cyVs?P-OeQrpyGQlAMyj8HUCQ5CvOQyM?OgBq?yJRr_5jz_mES Scale = 1:33.6 1 2 3 4 5 6 7 3x4 3x4 2x4 6x6 9-11-8 9-11-8 -1-0-0 1-0-0 5-6-15 5-6-15 9-10-0 4-3-1 9-11-8 0-1-8 0-6-125-6-85-1-00-5-85-6-86.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.30 0.41 0.23 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.11 -0.22 0.00 (loc) 2-5 2-5 5 l/defl >999 >535 n/a L/d 240 180 n/a PLATES MT20 Weight: 41 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x6 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)2=0-3-0, 5=0-1-8 Max Horz 2=143(LC 9) Max Uplift 2=-13(LC 12) Max Grav 2=459(LC 1), 5=384(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-404/104 BOT CHORD 2-5=-203/298 WEBS 3-5=-342/192 NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 9-9-12 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Bearing at joint(s) 5 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 5) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 5. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. July 6,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job TG-143 Truss T05 Truss Type Monopitch Qty 4 Ply 1 Pyatt - 143 TG Job Reference (optional) I41920925 8.240 s Mar 9 2020 MiTek Industries, Inc. Mon Jul 6 14:09:22 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:p21FHLh8zPRQybDyxoj12cyVs?P-sr_D0IG2WTUpKIshm8cRScz46OmuwGo5X5bYd9z_mER Scale = 1:16.8 1 2 3 6 5 4 7 8 9 6x6 3x6 3x4 3x4 3x4 5-9-10 5-9-10 -1-1-14 1-1-14 5-9-10 5-9-10 0-8-140-7-122-11-90-3-80-10-122-11-94.00 12 Plate Offsets (X,Y)-- [3:0-2-4,0-2-15] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.50 0.22 0.26 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.02 -0.03 -0.00 (loc) 5-6 5-6 8 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 20 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud *Except* 2-6: 2x6 SPF No.2 OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 5-9-10 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)6=0-1-8, 8=0-1-8 Max Horz 6=55(LC 12) Max Uplift 6=-16(LC 12) Max Grav 6=340(LC 1), 8=319(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-6=-281/165 NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) -1-1-14 to 1-10-2, Interior(1) 1-10-2 to 5-4-6 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Bearing at joint(s) 6, 8 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 5) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 6, 8. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 6. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 166 lb down and 51 lb up at 4-9-8 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 9) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-2=-60, 2-3=-60, 4-6=-20 Concentrated Loads (lb) Vert: 9=-157(B) July 6,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job TG-143 Truss T05A Truss Type Half Hip Qty 3 Ply 1 Pyatt - 143 TG Job Reference (optional) I41920926 8.240 s Mar 9 2020 MiTek Industries, Inc. Mon Jul 6 14:09:24 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:p21FHLh8zPRQybDyxoj12cyVs?P-oD6zR_II25kWac03tZfvX12KZCRoOBrO?P4eh2z_mEP Scale: 3/4"=1' 1 2 3 4 5 9 8 7 6 1110 12 13 14 15 3x4 3x4 3x4 5x8 3x4 3x4 4x6 3x4 4-11-8 4-11-8 6-3-0 1-3-8 -1-0-0 1-0-0 4-11-8 4-11-8 6-3-0 1-3-8 0-11-120-7-122-6-71-7-22-7-90-7-41-7-20-7-44.00 12 Plate Offsets (X,Y)-- [5:0-1-8,0-3-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.88 0.26 0.22 DEFL. Vert(LL) Vert(CT) Horz(CT) Wind(LL) in -0.02 -0.06 0.01 0.01 (loc) 7-8 7-8 13 9 l/defl >999 >999 n/a >999 L/d 480 360 n/a 240 PLATES MT20 Weight: 21 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 4-7, 4-5. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)12=0-1-12, 13=0-3-0 Max Horz 12=75(LC 12) Max Grav 12=370(LC 1), 13=571(LC 17) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-285/0, 4-7=-305/1, 4-5=-399/0 WEBS 5-7=-2/407, 2-12=-557/14, 5-13=-619/0 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 5-9-12 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Bearing at joint(s) 12, 13 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 7) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 12. 8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Load case(s) 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26 has/have been modified. Building designer must review loads to verify that they are correct for the intended use of this truss. 10) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-2=-60, 2-3=-60, 4-5=-80, 6-9=-20 Concentrated Loads (lb) Vert: 15=-370 Continued on page 2 July 6,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job TG-143 Truss T05A Truss Type Half Hip Qty 3 Ply 1 Pyatt - 143 TG Job Reference (optional) I41920926 8.240 s Mar 9 2020 MiTek Industries, Inc. Mon Jul 6 14:09:24 2020 Page 2 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:p21FHLh8zPRQybDyxoj12cyVs?P-oD6zR_II25kWac03tZfvX12KZCRoOBrO?P4eh2z_mEP LOAD CASE(S) Standard 2) Dead + 0.75 Roof Live (balanced) + 0.75 Attic Floor: Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-2=-50, 2-3=-50, 4-5=-129, 6-9=-20 Concentrated Loads (lb) Vert: 15=-353 3) Dead + Uninhabitable Attic Without Storage: Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 1-2=-20, 2-3=-20, 4-5=-40, 6-9=-40 Concentrated Loads (lb) Vert: 15=-335 4) Dead + 0.6 C-C Wind (Pos. Internal) Case 1: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 1-2=44, 2-14=35, 3-14=24, 4-5=12, 6-9=-12 Horz: 1-2=-56, 2-14=-47, 3-14=-36, 3-4=7, 6-11=29, 8-10=18 Concentrated Loads (lb) Vert: 15=-189 5) Dead + 0.6 C-C Wind (Pos. Internal) Case 2: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 1-2=20, 2-3=35, 4-5=12, 6-9=-12 Horz: 1-2=-32, 2-3=-47, 3-4=-40, 6-11=-18, 8-10=-29 Concentrated Loads (lb) Vert: 15=-189 6) Dead + 0.6 C-C Wind (Neg. Internal) Case 1: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 1-2=-5, 2-3=-39, 4-5=-51, 6-9=-20 Horz: 1-2=-15, 2-3=19, 3-4=-24, 6-11=-27, 8-10=-21 Concentrated Loads (lb) Vert: 15=-334 7) Dead + 0.6 C-C Wind (Neg. Internal) Case 2: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 1-2=-35, 2-3=-39, 4-5=-51, 6-9=-20 Horz: 1-2=15, 2-3=19, 3-4=23, 6-11=21, 8-10=27 Concentrated Loads (lb) Vert: 15=-351 8) Dead + 0.6 MWFRS Wind (Pos. Internal) Left: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 1-2=19, 2-3=8, 4-5=6, 6-9=-12 Horz: 1-2=-31, 2-3=-20, 3-4=-8, 6-11=14, 8-10=11 Concentrated Loads (lb) Vert: 15=-220 9) Dead + 0.6 MWFRS Wind (Pos. Internal) Right: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 1-2=-0, 2-3=4, 4-5=6, 6-9=-12 Horz: 1-2=-12, 2-3=-16, 3-4=-20, 6-11=-11, 8-10=-14 Concentrated Loads (lb) Vert: 15=-220 10) Dead + 0.6 MWFRS Wind (Neg. Internal) Left: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 1-2=-16, 2-3=-21, 4-5=-33, 6-9=-20 Horz: 1-2=-4, 2-3=1, 3-4=24, 6-11=6, 8-10=20 Concentrated Loads (lb) Vert: 15=-335 11) Dead + 0.6 MWFRS Wind (Neg. Internal) Right: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 1-2=-8, 2-3=-12, 4-5=-33, 6-9=-20 Horz: 1-2=-12, 2-3=-8, 3-4=-3, 6-11=-20, 8-10=-6 Concentrated Loads (lb) Vert: 15=-307 12) Dead + 0.6 MWFRS Wind (Pos. Internal) 1st Parallel: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 1-2=22, 2-3=11, 4-5=-1, 6-9=-12 Horz: 1-2=-34, 2-3=-23, 3-4=-27, 6-11=18, 8-10=-18 Concentrated Loads (lb) Vert: 15=-233 13) Dead + 0.6 MWFRS Wind (Pos. Internal) 2nd Parallel: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 1-2=14, 2-3=2, 4-5=-10, 6-9=-12 Horz: 1-2=-26, 2-3=-14, 3-4=-18, 6-11=18, 8-10=-18 Concentrated Loads (lb) Vert: 15=-241 14) Dead + 0.6 MWFRS Wind (Neg. Internal) 1st Parallel: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 1-2=-16, 2-3=-21, 4-5=-33, 6-9=-20 Horz: 1-2=-4, 2-3=1, 3-4=5, 6-11=10, 8-10=-10 Concentrated Loads (lb) Vert: 15=-331 Continued on page 3 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job TG-143 Truss T05A Truss Type Half Hip Qty 3 Ply 1 Pyatt - 143 TG Job Reference (optional) I41920926 8.240 s Mar 9 2020 MiTek Industries, Inc. Mon Jul 6 14:09:24 2020 Page 3 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:p21FHLh8zPRQybDyxoj12cyVs?P-oD6zR_II25kWac03tZfvX12KZCRoOBrO?P4eh2z_mEP LOAD CASE(S) Standard 15) Dead + 0.6 MWFRS Wind (Neg. Internal) 2nd Parallel: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 1-2=-16, 2-3=-21, 4-5=-33, 6-9=-20 Horz: 1-2=-4, 2-3=1, 3-4=5, 6-11=10, 8-10=-10 Concentrated Loads (lb) Vert: 15=-331 16) Dead: Lumber Increase=0.90, Plate Increase=0.90 Plt. metal=0.90 Uniform Loads (plf) Vert: 1-2=-20, 2-3=-20, 4-5=-40, 6-9=-20 Concentrated Loads (lb) Vert: 15=-300 17) Dead + 0.75 Roof Live (bal.) + 0.75 Attic Floor + 0.75(0.6 MWFRS Wind (Neg. Int) Left): Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 1-2=-47, 2-3=-50, 4-5=-123, 6-9=-20 Horz: 1-2=-3, 2-3=0, 3-4=18, 6-11=4, 8-10=15 Concentrated Loads (lb) Vert: 15=-378 18) Dead + 0.75 Roof Live (bal.) + 0.75 Attic Floor + 0.75(0.6 MWFRS Wind (Neg. Int) Right): Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 1-2=-41, 2-3=-44, 4-5=-123, 6-9=-20 Horz: 1-2=-9, 2-3=-6, 3-4=-3, 6-11=-15, 8-10=-4 Concentrated Loads (lb) Vert: 15=-358 19) Dead + 0.75 Roof Live (bal.) + 0.75 Attic Floor + 0.75(0.6 MWFRS Wind (Neg. Int) 1st Parallel): Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 1-2=-47, 2-3=-50, 4-5=-123, 6-9=-20 Horz: 1-2=-3, 2-3=0, 3-4=4, 6-11=7, 8-10=-7 Concentrated Loads (lb) Vert: 15=-376 20) Dead + 0.75 Roof Live (bal.) + 0.75 Attic Floor + 0.75(0.6 MWFRS Wind (Neg. Int) 2nd Parallel): Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 1-2=-47, 2-3=-50, 4-5=-123, 6-9=-20 Horz: 1-2=-3, 2-3=0, 3-4=4, 6-11=7, 8-10=-7 Concentrated Loads (lb) Vert: 15=-376 21) Dead + 0.6 C-C Wind Min. Down: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 1-2=4, 2-3=-28, 4-5=-40, 6-9=-12 Horz: 1-2=-16, 2-3=16, 3-4=-16, 6-11=-16, 8-10=-16 Concentrated Loads (lb) Vert: 15=-272 22) Dead + 0.6 C-C Wind Min. Upward: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 1-2=4, 2-3=4, 4-5=-8, 6-9=-12 Horz: 1-2=-16, 2-3=-16, 3-4=16, 6-11=16, 8-10=16 Concentrated Loads (lb) Vert: 15=-272 23) 1st Dead + Roof Live (unbalanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-2=-60, 2-3=-60, 4-5=-40, 6-9=-20 Concentrated Loads (lb) Vert: 15=-370 24) 2nd Dead + Roof Live (unbalanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-2=-20, 2-3=-20, 4-5=-80, 6-9=-20 Concentrated Loads (lb) Vert: 15=-370 25) 3rd Dead + 0.75 Roof Live (unbalanced) + 0.75 Attic Floor: Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-2=-50, 2-3=-50, 4-5=-99, 6-9=-20 Concentrated Loads (lb) Vert: 15=-353 26) 4th Dead + 0.75 Roof Live (unbalanced) + 0.75 Attic Floor: Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-2=-20, 2-3=-20, 4-5=-129, 6-9=-20 Concentrated Loads (lb) Vert: 15=-353 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job TG-143 Truss T06 Truss Type MONOPITCH Qty 2 Ply 1 Pyatt - 143 TG Job Reference (optional) I41920927 8.240 s Mar 9 2020 MiTek Industries, Inc. Mon Jul 6 14:09:25 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:p21FHLh8zPRQybDyxoj12cyVs?P-GPfMeJJwpOsNBmbFRGA84Ebg?cqO7hZYE3pCEUz_mEO Scale = 1:12.9 1 2 3 4 5 6 3x4 3x4 3x4 3-7-8 3-7-8 -1-0-0 1-0-0 3-6-0 3-6-0 3-7-8 0-1-8 0-5-122-0-41-8-120-3-82-0-45.10 12 Plate Offsets (X,Y)-- [4:Edge,0-2-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.13 0.11 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.01 -0.01 0.00 (loc) 2-4 2-4 4 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 11 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 3-7-8 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)2=0-3-8, 4=0-1-8 Max Horz 2=48(LC 9) Max Uplift 2=-26(LC 12) Max Grav 2=214(LC 1), 4=122(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 3-5-12 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Bearing at joint(s) 4 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 5) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 4. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. July 6,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job TG-143 Truss T06A Truss Type MONOPITCH Qty 3 Ply 1 Pyatt - 143 TG Job Reference (optional) I41920928 8.240 s Mar 9 2020 MiTek Industries, Inc. Mon Jul 6 14:09:27 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:p21FHLh8zPRQybDyxoj12cyVs?P-Don63?KBL065R3keZhCc9fg14PWAbbJrhNIJINz_mEM Scale = 1:14.2 1 2 3 5 4 6 3x4 3x4 3x4 3x4 3-3-14 3-3-14 -1-1-14 1-1-14 3-2-6 3-2-6 3-3-14 0-1-8 0-10-50-7-142-6-120-3-82-3-40-3-82-6-125.10 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.10 0.09 0.05 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.01 -0.01 -0.00 (loc) 4-5 4-5 4 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 15 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 3-3-14 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)4=0-1-8, 5=0-1-8 Max Horz 5=65(LC 9) Max Uplift 4=-11(LC 9), 5=-26(LC 12) Max Grav 4=104(LC 1), 5=216(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) -1-1-14 to 1-10-2, Interior(1) 1-10-2 to 3-2-2 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Bearing at joint(s) 4, 5 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 5) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 4, 5. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4, 5. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. July 6,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job TG-143 Truss TG01 Truss Type GABLE Qty 1 Ply 2 Pyatt - 143 TG Job Reference (optional) I41920929 8.240 s Mar 9 2020 MiTek Industries, Inc. Mon Jul 6 14:09:29 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:p21FHLh8zPRQybDyxoj12cyVs?P-9BvsUhMRtdMpgNu1g6E4E4mG5D_13Mp78hnPNFz_mEK Scale = 1:36.2 1 2 3 4 5 6 10 9 8 7 11 14 15 16 17 4x6 3x8 3x4 4x6 4x8 4x8 3x12 3x8 2x4 2x4 2x4 2x4 3-0-85-11-0 5-11-0 9-11-0 4-0-0 13-11-0 4-0-0 19-10-0 5-11-0 -1-0-0 1-0-0 5-11-0 5-11-0 9-11-0 4-0-0 13-11-0 4-0-0 19-10-0 5-11-0 0-6-125-6-40-6-126.00 12 Plate Offsets (X,Y)-- [6:0-8-0,0-0-1] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.51 0.96 0.62 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.08 -0.16 0.03 (loc) 6-7 6-7 6 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 178 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x6 SPF No.2 WEBS 2x4 SPF-S Stud *Except* 3-11: 2x6 SPF No.2 OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 5-2-10 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. JOINTS 1 Brace at Jt(s): 11 REACTIONS. (size)6=0-3-8, 2=0-3-8 Max Horz 2=70(LC 26) Max Grav 6=2999(LC 1), 2=1719(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-3008/0, 3-4=-2511/0, 4-5=-2532/0, 5-6=-4563/0 BOT CHORD 2-10=0/2572, 8-10=0/2559, 7-8=0/3967, 6-7=0/3967 WEBS 8-11=0/2014, 4-11=0/2015, 5-8=-2247/0, 5-7=0/2074, 3-8=-463/97, 3-10=0/315 NOTES- 1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows: Top chords connected as follows: 2x4 - 1 row at 0-9-0 oc. Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-9-0 oc. Webs connected as follows: 2x4 - 1 row at 0-9-0 oc, 2x6 - 2 rows staggered at 0-9-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Unbalanced roof live loads have been considered for this design. 4) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 5) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 6) Gable studs spaced at 1-4-0 oc. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 9) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 10) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 77 lb down and 60 lb up at 5-11-0 on top chord, and 136 lb down and 44 lb up at 3-11-0, 30 lb down at 5-11-0, 30 lb down at 7-11-0, 94 lb down and 59 lb up at 10-0-12, 694 lb down at 12-0-12, 694 lb down at 14-0-12, and 694 lb down at 16-2-12, and 694 lb down at 18-0-12 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. LOAD CASE(S) Standard Continued on page 2 July 6,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job TG-143 Truss TG01 Truss Type GABLE Qty 1 Ply 2 Pyatt - 143 TG Job Reference (optional) I41920929 8.240 s Mar 9 2020 MiTek Industries, Inc. Mon Jul 6 14:09:29 2020 Page 2 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:p21FHLh8zPRQybDyxoj12cyVs?P-9BvsUhMRtdMpgNu1g6E4E4mG5D_13Mp78hnPNFz_mEK LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-4=-60, 4-6=-60, 2-6=-20 Concentrated Loads (lb) Vert: 9=-21(B) 8=-94(B) 7=-694(B) 3=-37(B) 10=-21(B) 14=-136(B) 15=-694(B) 16=-694(B) 17=-694(B) 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job TG-143 Truss TG05 Truss Type Half Hip Girder Qty 1 Ply 1 Pyatt - 143 TG Job Reference (optional) I41920930 8.240 s Mar 9 2020 MiTek Industries, Inc. Mon Jul 6 14:09:30 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:p21FHLh8zPRQybDyxoj12cyVs?P-dNTFi1M3exUgIXTDEpmJnIIPUdQwonbHNLXzviz_mEJ Scale = 1:20.3 1 2 3 4 7 6 5 98 10 11 12 13 14 4x8 6x6 5x8 3x4 4x6 4x8 3x6 4-9-0 4-9-0 10-6-0 5-9-0 -1-0-0 1-0-0 4-9-0 4-9-0 10-6-0 5-9-0 0-11-120-7-122-6-120-7-40-7-42-6-124.00 12 Plate Offsets (X,Y)-- [2:0-1-8,0-1-4], [3:0-5-8,0-2-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.60 0.53 0.72 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.04 -0.09 0.01 (loc) 5-6 5-6 11 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 40 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 5-5-11 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 3-4. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)10=0-1-12, 11=0-3-0 Max Horz 10=49(LC 23) Max Uplift 10=-68(LC 4), 11=-87(LC 4) Max Grav 10=715(LC 1), 11=720(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-1092/114, 5-9=-34/484, 4-9=-34/484 BOT CHORD 6-7=-28/393, 5-6=-109/1022 WEBS 3-6=-8/416, 3-5=-921/96, 2-6=-89/613, 2-10=-1013/87, 4-11=-734/89 NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) Provide adequate drainage to prevent water ponding. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Bearing at joint(s) 10, 11 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 6) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 10. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 10, 11. 8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 10) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 74 lb down and 25 lb up at 10-0-12 on top chord, and 164 lb down and 11 lb up at 5-0-12, 163 lb down and 40 lb up at 4-2-4, 84 lb down and 31 lb up at 6-2-4, and 20 lb down and 25 lb up at 6-2-12, and 84 lb down and 31 lb up at 8-2-4 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 11) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Continued on page 2 July 6,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job TG-143 Truss TG05 Truss Type Half Hip Girder Qty 1 Ply 1 Pyatt - 143 TG Job Reference (optional) I41920930 8.240 s Mar 9 2020 MiTek Industries, Inc. Mon Jul 6 14:09:30 2020 Page 2 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:p21FHLh8zPRQybDyxoj12cyVs?P-dNTFi1M3exUgIXTDEpmJnIIPUdQwonbHNLXzviz_mEJ LOAD CASE(S) Standard Uniform Loads (plf) Vert: 1-2=-60, 2-3=-60, 3-4=-60, 5-7=-20 Concentrated Loads (lb) Vert: 4=-72 6=-155(F) 12=-163 13=-104(F=-20) 14=-84 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job TG-143 Truss TG05A Truss Type Half Hip Qty 1 Ply 1 Pyatt - 143 TG Job Reference (optional) I41920931 8.240 s Mar 9 2020 MiTek Industries, Inc. Mon Jul 6 14:09:31 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:p21FHLh8zPRQybDyxoj12cyVs?P-5Z1dvNNhOEcXwh2PoXHYJVrZu1r5XMsQc?GWR8z_mEI Scale: 3/4"=1' 1 2 3 4 5 9 8 7 6 1110 12 13 14 3x4 3x4 3x4 5x8 3x4 3x4 4x6 3x4 4-11-8 4-11-8 6-3-0 1-3-8 -1-0-0 1-0-0 4-11-8 4-11-8 6-3-0 1-3-8 0-11-120-7-122-6-71-7-22-7-90-7-41-7-20-7-44.00 12 Plate Offsets (X,Y)-- [5:0-1-12,0-2-12] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.68 0.22 0.20 DEFL. Vert(LL) Vert(CT) Horz(CT) Wind(LL) in -0.02 -0.05 -0.01 0.01 (loc) 7-8 7-8 13 8 l/defl >999 >999 n/a >999 L/d 480 360 n/a 240 PLATES MT20 Weight: 21 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 4-7, 4-5. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)12=0-1-12, 13=0-3-0 Max Horz 12=75(LC 12) Max Uplift 12=-15(LC 12), 13=-11(LC 8) Max Grav 12=341(LC 1), 13=333(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 4-5=-306/95 WEBS 5-7=-115/374, 2-12=-490/112, 5-13=-358/116 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 5-9-12 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Bearing at joint(s) 12, 13 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 7) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 12. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 12, 13. 9) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 10) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 11) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 164 lb down and 45 lb up at 5-0-12 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 12) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-2=-60, 2-3=-60, 4-5=-60, 6-9=-20 Continued on page 2 July 6,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job TG-143 Truss TG05A Truss Type Half Hip Qty 1 Ply 1 Pyatt - 143 TG Job Reference (optional) I41920931 8.240 s Mar 9 2020 MiTek Industries, Inc. Mon Jul 6 14:09:31 2020 Page 2 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:p21FHLh8zPRQybDyxoj12cyVs?P-5Z1dvNNhOEcXwh2PoXHYJVrZu1r5XMsQc?GWR8z_mEI LOAD CASE(S) Standard Concentrated Loads (lb) Vert: 7=-155(B) 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job TG-143 Truss V01 Truss Type Valley Qty 1 Ply 1 Pyatt - 143 TG Job Reference (optional) I41920932 8.240 s Mar 9 2020 MiTek Industries, Inc. Mon Jul 6 14:09:33 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:p21FHLh8zPRQybDyxoj12cyVs?P-1y8NK2PywssF9_CovyJ0Oww0NqYe?JYj3JldW0z_mEG Scale = 1:11.8 1 2 3 3x4 3x4 3x4 3-7-1 3-7-1 0-0-41-9-86.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.24 0.15 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 8 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF-S Stud WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 3-7-1 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=3-6-9, 3=3-6-9 Max Horz 1=39(LC 11) Max Grav 1=112(LC 1), 3=112(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Gable requires continuous bottom chord bearing. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. July 6,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job TG-143 Truss V02 Truss Type Valley Qty 1 Ply 1 Pyatt - 143 TG Job Reference (optional) I41920933 8.240 s Mar 9 2020 MiTek Industries, Inc. Mon Jul 6 14:09:34 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:p21FHLh8zPRQybDyxoj12cyVs?P-W8ilXOQah9_6n8n_TfqFx8T?7EmJklosIzVA2Tz_mEF Scale = 1:19.2 1 2 3 4 5 3x4 3x4 3x4 6-3-1 6-3-1 0-0-43-1-86.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 1.00 0.63 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 15 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF-S Stud WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=6-2-9, 3=6-2-9 Max Horz 1=75(LC 9) Max Grav 1=219(LC 1), 3=219(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) 0-7-9 to 3-7-9, Interior(1) 3-7-9 to 6-1-5 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Gable requires continuous bottom chord bearing. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. July 6,2020 PRODUCT CODE APPROVALSLATERAL BRACING LOCATIONIndicates location where bearings(supports) occur. Icons vary butreaction section indicates jointnumber where bearings occur.Min size shown is for crushing only.Indicated by symbol shown and/orby text in the bracing section of theoutput. Use T or I bracingif indicated.The first dimension is the plate width measured perpendicular to slots. Second dimension isthe length parallel to slots.Center plate on joint unless x, yoffsets are indicated.Dimensions are in ft-in-sixteenths.Apply plates to both sides of trussand fully embed teeth.1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI.2. Truss bracing must be designed by an engineer. For wide truss spacing, individual lateral braces themselves may require bracing, or alternative Tor I bracing should be considered.3. Never exceed the design loading shown and never stack materials on inadequately braced trusses.4. Provide copies of this truss design to the building designer, erection supervisor, property owner and all other interested parties.5. Cut members to bear tightly against each other.6. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI 1.7. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI 1.8. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication.9. Unless expressly noted, this design is not applicable for use with fire retardant, preservative treated, or green lumber.10. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection.11. Plate type, size, orientation and location dimensions indicated are minimum plating requirements.12. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified.13. Top chords must be sheathed or purlins provided at spacing indicated on design.14. Bottom chords require lateral bracing at 10 ft. spacing, or less, if no ceiling is installed, unless otherwise noted.15. Connections not shown are the responsibility of others.16. Do not cut or alter truss member or plate without prior approval of an engineer.17. Install and load vertically unless indicated otherwise.18. Use of green or treated lumber may pose unacceptable environmental, health or performance risks. Consult with project engineer before use.19. Review all portions of this design (front, back, words and pictures) before use. Reviewing pictures alone is not sufficient.20. Design assumes manufacture in accordance with ANSI/TPI 1 Quality Criteria.21.The design does not take into account any dynamic or other loads other than those expressly stated.Failure to Follow Could Cause PropertyDamage or Personal Injury (Drawings not to scale)© 2012 MiTek® All Rights ReservedMiTek Engineering Reference Sheet: MII-7473 rev. 5/19/2020edge of truss.from outside"16/1-0ICC-ES Reports:ESR-1311, ESR-1352, ESR1988ER-3907, ESR-2362, ESR-1397, ESR-3282JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISEAROUND THE TRUSS STARTING AT THE JOINT FARTHEST TOTHE LEFT.CHORDS AND WEBS ARE IDENTIFIED BY END JOINTNUMBERS/LETTERS.W 4 - 6 W3-6W3 - 7 W2-7W1-7C1-8 C5-6C6-7C7-8C4-5 C3-4C2-3C1-2TOP CHORD TOP CHORD 87654321BOTTOM CHORDSTOP CHORDSBEARING4 x 4PLATE SIZEThis symbol indicates the required direction of slots inconnector plates."16/1For 4 x 2 orientation, locateplates 0- 1"4/3PLATE LOCATION AND ORIENTATIONSymbolsNumbering SystemGeneral Safety Notes *Plate location details available in MiTek 20/20software or upon request.Industry Standards:ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction.DSB-89: Design Standard for Bracing.BCSI: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses.6-4-8WEBSTrusses are designed for wind loads in the plane of the truss unless otherwise shown.Lumber design values are in accordance with ANSI/TPI 1 section 6.3 These truss designs rely on lumber values established by others.dimensions shown in ft-in-sixteenths