HomeMy WebLinkAboutGN002 - 525WMbn GREAT ROOM
1/2" = 1'-0"
RELEASED FOR CONSTRUCTION
Subject to compliance with all regulations
of State and Local Codes
City of Camel
n" &aa,e»Q
DATE: 07/24/20
n BRICK WALL AT LOWER LEVEL
112" = 1'-0"
LANAI FIREPLACE
n SECTION PGARAGE ENTRY DOOR
n MUD ROOM BENCHw/CUBBIES
LANDING 1 /1
FIN. MAIN LEVEL n
.O. FOUNDATION nV
GRANULAR FILL TO
12"ABOVE TOP OF
CONCRETE FOOTING
4" DRAIN
7116" ROOF
12°
SEE ROOF PLAN
ROOF SHINGLES, FOR IN U CLEARANCE
\\ FOR INSULATION
SEE ELEV.
SEE ELEV. FOR
R-15INSULATION
711F ZIP SHEATHING
1x6 BAND BOARD WIMETAL
DRIP EDGE FLASHING TYP.
SLOPED BRICK ROWLOCK SILL
WIFIRESTONE RUBBER FLASHING
TIE
THROUGH WALL FLASHING
NOTE: OFFSET FACE OF STUD 112"
FROM FACE OF FOUND. WALL
GRADE
Op Oe Oe Oe
°" °_ °_ °_
Qi. °a °a °a
o; o; o;
o, o, og
n
R-38INSULATION
BOTTOM TRUSS CHORD
DECKING
SEE FLOOR FRAMING
PLAN FOR JOIST LAYOUT
112" DRYWALL
2A STUD WALL
AT 16" O.C.
2A SILL PLATE
3I4" DECKING
— R-13 BATT INSULATION
BETWEEN JOISTS TYP.
oa Oe Oa
lAoa o;
x
w
x
J
J
>a
0
u-
z
O
a
w
J
W
W
W
d)
PLAN FOR JOIST LAYOUT
R-10 VINYL FACED BATT INSULATION
DOWN 47 FROM TOP OF FNDN. WALL
IN UNFINISHED BASEMENT AREAS
(R-13IN BASEMENT FINISHED WALLS)
TYPICAL FOUNDATION WALL:
a 8" POURED CONCRETE WALL
a SILL ANCHOR BOLTS @ 6V O.C.
"16"X8" CONCRETE FOOTING
"#3 STEEL WALL REINFORCING
2" FROM FACE OF WALL
"LOOP WIRE REINFORCING
_ 4" CONC. SLAB ON GRADE
W16 MIL. VAPOR BARRIER
MIN. GRANULAR FILL
4" DRAIN TILE
CONCRETE FOOTER
TYPICAL WALL SECTION
APPROVED
By Andrew Lund at 9:26 am, Jun 01, 2020