HomeMy WebLinkAbout48LV - Truss PlacementFrame down tray ceiling in the field
8-01-02 TOP
8-01-02 TOP
8-01-02 TOP
10-01-02 TOP
8-01-02 TOP
8-01-02 TOP
10-01-02 TOP
10-01-02 TOP
9-01-02 TOP
HTU26
HTU26
HTU26
HTU26
HTU26
HTU26
HTU26
HTU26
HTU26
HTU26
HTU26
HTU26
HTU26
HTU26
HTU26
HTU26
HTU26
HTU26
HTU26
HTU26
HTU26
HTU26
MUS26
MUS26
MUS26
HGUS26-2 HGUS26-2
Field frame dormer end wall
2x4 ledger
2x4 ledger
GE01
TG01
TG02
T02
T03
T04
T05
T06
T07
T08
TG03
T11
TG04
GE02
GE03
TG05
TG06
T16
T17
T17
T16
TG06
CG01
CG01
J01
M02
J02
M02
TG07
TG08
T18
T21
T22
T23
T24
TG09
M05
TG10
T25
T26
CG02
J03
M08
CG03
J04
J05
V01
V02
V03
V04
V05
V06
V07
V08
V09
V10
V11
V12
V13
V14
V15
V16
V17
V18
V19
V20
V21
V22
PB02
PB03
PB06
PB07
PBE01
PBE02
PB10
PB11
PBE03
T01(5)
T09(3)
T10(3)
T12(2) T13(7)
T14(4)
T15(2)
M01(3)
T19(4)
T20(2)
M03(6)
M04(9)
M06(20)
M06(8)
M07(2)
M09(12)
M10(5)
PB01(10)
PB04(3) PB05(9)
PB09(5)
PB08(6)
1
12-00-00 21-03-00 12-05-00 7-00-00 3-03-00
4-00-00 22-11-00 23-08-00 12-00-00
12-00-00 32-00-00 21-11-00
63-11-00
7-08-04
IRC 2018
TPI 2014 20TLL - 10TDL - 10BDL
Wedgewood Building Company
Burrell Residence - Tarkington
48 Laura Vista
1/4"=1'
July 14, 2020
PH
B20001926
CUSTOMER:
LOCATION:
MODEL:
JOB #:
DATE:
DESIGNER: DESIGN INFORMATION: SCALE:
9028 Old SR 67 South
Mooresville, IN 46158
(317) 834-5380
Truss Placement Guide
1) This layout is intended for the purpose of truss location
and placement only. Refer to the building plans for actual
building construction.
2) All dimensions shown 00-00-00 are in feet-inches-sixteenths.
3) Trusses are spaced 24" on center unless otherwise noted.
4) Do not cut or modify trusses.
5) Refer to the individual truss design drawings for the location
of member bracing, uplift and truss end reactions.
6) Installation of all temporary and permanent bracing is
essential. See truss drawings, BCSI-B2 Summary Sheet
and building designer requirements.
7) Non-bearing walls may not be shown on layout.
Left end of truss, as shown on engineering
drawing, is indicated by the triangle symbol