2 Heritage at Spring Mill - Seals
16023 Swingley Ridge Rd Chesterfield, MO 63017 314-434-1200 MiTek USA, Inc. Re: The truss drawing(s) referenced below have been prepared by MiTek USA, Inc. under my direct supervision based on the parameters provided by ProBuild (CarterLee Bldg Components). June 25,2020 Liu, Xuegang Pages or sheets covered by this seal: I41794842 thru I41794939 My license renewal date for the state of Indiana is July 31, 2020. 2_Heritage_at_Spring_Mill 2 Heritage at Spring Mill IMPORTANT NOTE: The seal on these truss component designs is a certification that the engineer named is licensed in the jurisdiction(s) identified and that the designs comply with ANSI/TPI 1. These designs are based upon parameters shown (e.g., loads, supports, dimensions, shapes and design codes), which were given to MiTek or TRENCO. Any project specific information included is for MiTek's or TRENCO's customers file reference purpose only, and was not taken into account in the preparation of these designs. MiTek or TRENCO has not independently verified the applicability of the design parameters or the designs for any particular building. Before use, the building designer should verify applicability of design parameters and properly incorporate these designs into the overall building design per ANSI/TPI 1, Chapter 2. 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 2_HERITAGE_AT_SPRING~L Truss GE01 Truss Type GABLE Qty 1 Ply 1 2 Heritage at Spring Mill Job Reference (optional) I41794842 8.240 s Mar 9 2020 MiTek Industries, Inc. Wed Jun 24 18:32:02 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:EvWg2tiHQVSzJMSEDMv2ODzW2H3-HC0zhqYfDuas5L8Qoj8iVu9Ogc30ssmd6IaLJ3z3_cB Scale = 1:67.8 Sheet Back Full Sheathing 1 Ply 7/16OSB8 1 2 3 4 5 6 7 8 9 10 11 12 23 22 21 20 19 18 17 16 15 14 13 24 25 3x4 3x4 3x6 5x10 MT18HS 5x10 MT18HS3x6 2x4 6x6 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 18-3-0 18-3-0 -1-3-8 1-3-8 14-5-10 14-5-10 18-3-0 3-9-6 1-1-010-6-710-8-1210-6-78.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.76 0.32 0.18 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 -0.00 -0.00 (loc) 1 1 13 l/defl n/r n/r n/a L/d 180 120 n/a PLATES MT20 MT18HS Weight: 349 lb FT = 20% GRIP 169/123 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud *Except* 12-13: 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 10-12. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 12-13, 10-15, 9-16, 11-14 REACTIONS.All bearings 18-3-0. (lb) - Max Horz 23=289(LC 7) Max Uplift All uplift 100 lb or less at joint(s) 23, 13, 15, 16, 17, 18, 19, 14 except 22=-156(LC 10) Max Grav All reactions 250 lb or less at joint(s) 13, 15, 16, 17, 18, 19, 20, 22, 14 except 23=290(LC 18) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-4=-267/176 NOTES-(14-15) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Corner(3E) -1-3-8 to 1-8-8, Exterior(2N) 1-8-8 to 11-5-10, Corner(3R) 11-5-10 to 15-1-12, Corner(3E) 15-1-12 to 18-1-12 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Provide adequate drainage to prevent water ponding. 5) All plates are MT20 plates unless otherwise indicated. 6) Gable requires continuous bottom chord bearing. 7) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 8) Gable studs spaced at 2-0-0 oc. 9) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 10) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 11) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 23, 13, 15, 16, 17, 18, 19, 14 except (jt=lb) 22=156. 12) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 13) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 14) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 15) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). June 25,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 2_HERITAGE_AT_SPRING~L Truss GE02 Truss Type Hip Supported Gable Qty 1 Ply 1 2 Heritage at Spring Mill Job Reference (optional) I41794843 8.240 s Mar 9 2020 MiTek Industries, Inc. Wed Jun 24 18:32:04 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:EvWg2tiHQVSzJMSEDMv2ODzW2H3-Eb8j6WavlVraKeIow8AAaJErDPnMKkzwZc3SNyz3_c9 Scale = 1:67.9 Sheet Front Full Sheathing 1 Ply 7/16OSB8 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 30 29 28 27 26 25 24 23 22 21 20 19 18 17 3x4 3x4 3x6 3x4 3x4 4x6 2x4 6x6 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 23-3-0 23-3-0 -1-0-0 1-0-0 8-2-0 8-2-0 15-1-0 6-11-0 23-3-0 8-2-0 24-3-0 1-0-0 1-7-011-1-51-7-011-1-514.00 12 Plate Offsets (X,Y)-- [7:0-2-11,Edge], [11:0-2-11,Edge], [25:0-3-0,0-1-4], [25:0-0-0,0-1-12], [26:0-1-4,0-0-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.31 0.14 0.20 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 -0.01 0.00 (loc) 16 16 17 l/defl n/r n/r n/a L/d 180 120 n/a PLATES MT20 Weight: 512 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud OTHERS 2x3 SPF No.2 *Except* 11-21,10-22,9-23,8-24: 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 7-11. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 11-21, 10-22, 9-23, 8-24, 6-26, 12-20 REACTIONS.All bearings 23-3-0. (lb) - Max Horz 30=-238(LC 8) Max Uplift All uplift 100 lb or less at joint(s) 17, 22, 23, 26, 28, 20, 19 except 30=-281(LC 6), 27=-107(LC 10), 29=-257(LC 7), 18=-179(LC 11) Max Grav All reactions 250 lb or less at joint(s) 17, 21, 22, 23, 24, 26, 27, 28, 20, 19, 18 except 30=346(LC 7), 29=318(LC 8) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 5-6=-212/263, 11-12=-238/294 NOTES-(13-14) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Corner(3E) -1-0-0 to 2-0-0, Exterior(2N) 2-0-0 to 5-0-15, Corner(3R) 5-0-15 to 11-1-0, Exterior(2N) 11-1-0 to 12-1-0, Corner(3R) 12-1-0 to 18-1-0, Exterior(2N) 18-1-0 to 21-1-1, Corner(3E) 21-1-1 to 24-3-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Provide adequate drainage to prevent water ponding. 5) Gable requires continuous bottom chord bearing. 6) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 7) Gable studs spaced at 2-0-0 oc. 8) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 9) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 17, 22, 23, 26, 28, 20, 19 except (jt=lb) 30=281, 27=107, 29=257, 18=179. 11) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 12) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 13) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 14) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.).June 25,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 2_HERITAGE_AT_SPRING~L Truss GE03 Truss Type GABLE Qty 1 Ply 1 2 Heritage at Spring Mill Job Reference (optional) I41794844 8.240 s Mar 9 2020 MiTek Industries, Inc. Wed Jun 24 18:32:04 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:EvWg2tiHQVSzJMSEDMv2ODzW2H3-Eb8j6WavlVraKeIow8AAaJEsXPoaKnLwZc3SNyz3_c9 Scale = 1:30.3 Sheet Back Full Sheathing 1 Ply 7/16OSB8 1 2 3 4 5 9 8 7 6 10 3x4 3x4 3x4 3x4 2x4 2x4 2x4 2x4 -0-11-0 0-11-0 6-0-0 6-0-0 1-1-05-1-08.00 12 Plate Offsets (X,Y)-- [6:Edge,0-2-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.23 0.12 0.04 DEFL. Vert(LL) Vert(CT) Horz(CT) in 0.00 -0.00 0.00 (loc) 2 1 6 l/defl n/r n/r n/a L/d 180 120 n/a PLATES MT20 Weight: 62 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud *Except* 5-6: 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 6-0-0. (lb) - Max Horz 9=136(LC 7) Max Uplift All uplift 100 lb or less at joint(s) 9, 6, 7, 8 Max Grav All reactions 250 lb or less at joint(s) 9, 6, 7, 8 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(10-11) 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Corner(3E) -0-11-0 to 2-0-0, Exterior(2N) 2-0-0 to 2-10-12, Corner(3E) 2-10-12 to 5-10-12 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) Gable requires continuous bottom chord bearing. 4) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 5) Gable studs spaced at 2-0-0 oc. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 9, 6, 7, 8. 9) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 10) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 11) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). June 25,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 2_HERITAGE_AT_SPRING~L Truss GE04 Truss Type GABLE Qty 1 Ply 1 2 Heritage at Spring Mill Job Reference (optional) I41794845 8.240 s Mar 9 2020 MiTek Industries, Inc. Wed Jun 24 18:32:05 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:EvWg2tiHQVSzJMSEDMv2ODzW2H3-ini5JsbXWpzRyot_TriP7Xn2Dp8O3EU3oGo0wOz3_c8 Scale = 1:28.5 Sheet Front Full Sheathing 1 Ply 7/16OSB8 1 2 3 4 5 9 8 7 6 10 3x4 3x4 3x4 3x4 3x4 2x4 2x4 2x4 2x4 6-1-4 6-1-4 4-9-0 4-9-0 6-1-4 1-4-4 1-3-144-5-141-7-02-10-148.00 12 6.00 12 Plate Offsets (X,Y)-- [4:0-2-0,0-2-3], [5:Edge,0-2-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.17 0.09 0.05 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a -0.00 (loc) - - 6 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 43 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 4-5. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 6-1-4. (lb) - Max Horz 9=82(LC 7) Max Uplift All uplift 100 lb or less at joint(s) 9, 6, 8 Max Grav All reactions 250 lb or less at joint(s) 9, 6, 7, 8 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(14-15) 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Corner(3E) 0-1-4 to 3-1-4, Corner(3R) 3-1-4 to 4-9-0, Corner(3E) 4-9-0 to 6-0-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) Provide adequate drainage to prevent water ponding. 4) Gable requires continuous bottom chord bearing. 5) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 6) Gable studs spaced at 2-0-0 oc. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 9) Bearing at joint(s) 9, 6, 7, 8 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 9, 6, 8. 11) Beveled plate or shim required to provide full bearing surface with truss chord at joint(s) 6, 7, 8. 12) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 13) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 14) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 15) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). June 25,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 2_HERITAGE_AT_SPRING~L Truss GE05 Truss Type GABLE Qty 1 Ply 1 2 Heritage at Spring Mill Job Reference (optional) I41794846 8.240 s Mar 9 2020 MiTek Industries, Inc. Wed Jun 24 18:32:06 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:ErDeBhooCW6W7KTmKQR8snz73g9-A_GTXCb9H65IZySB1ZDefkKDcDUJoaaD0wYZSqz3_c7 Scale = 1:53.5 Sheet Front Full Sheathing 1 Ply 7/16OSB8 1 2 3 4 5 6 7 8 9 16 15 14 13 12 11 10 3x4 3x4 4x6 3x4 3x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 11-11-0 11-11-0 -1-0-0 1-0-0 5-11-8 5-11-8 11-11-0 5-11-8 12-11-0 1-0-0 1-7-08-6-71-7-014.00 12 Plate Offsets (X,Y)-- [5:Edge,0-1-14] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.19 0.11 0.51 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 -0.01 0.00 (loc) 9 9 10 l/defl n/r n/r n/a L/d 180 120 n/a PLATES MT20 Weight: 182 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 6-0-0 oc bracing. REACTIONS.All bearings 11-11-0. (lb) - Max Horz 16=-188(LC 8) Max Uplift All uplift 100 lb or less at joint(s) 10, 14, 12 except 16=-108(LC 6), 15=-161(LC 10), 11=-159(LC 11) Max Grav All reactions 250 lb or less at joint(s) 16, 10, 13, 14, 15, 12, 11 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 4-5=-189/252, 5-6=-189/252 WEBS 5-13=-316/164 NOTES-(11-12) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Corner(3E) -1-0-0 to 1-11-7, Exterior(2N) 1-11-7 to 2-11-8, Corner(3R) 2-11-8 to 8-11-8, Exterior(2N) 8-11-8 to 9-11-0, Corner(3E) 9-11-0 to 12-11-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Gable requires continuous bottom chord bearing. 5) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 6) Gable studs spaced at 2-0-0 oc. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 10, 14, 12 except (jt=lb) 16=108, 15=161, 11=159. 10) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 11) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 12) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). June 25,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 2_HERITAGE_AT_SPRING~L Truss GE06 Truss Type Common Supported Gable Qty 1 Ply 1 2 Heritage at Spring Mill Job Reference (optional) I41794847 8.240 s Mar 9 2020 MiTek Industries, Inc. Wed Jun 24 18:32:07 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:EvWg2tiHQVSzJMSEDMv2ODzW2H3-eAprkYco2QD8B61NbGktCysNudqGX55MFaH6_Gz3_c6 Scale = 1:57.1 Sheet Back Full Sheathing 1 Ply 7/16OSB8 1 2 3 4 5 6 7 8 9 10 17 16 15 14 13 12 113x8 3x4 4x6 3x8 3x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 12-11-0 12-11-0 6-5-8 6-5-8 12-11-0 6-5-8 13-11-0 1-0-0 1-7-09-1-71-7-014.00 12 Plate Offsets (X,Y)-- [5:Edge,0-1-14], [11:Edge,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.22 0.12 0.24 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 -0.01 0.00 (loc) 10 10 11 l/defl n/r n/r n/a L/d 180 120 n/a PLATES MT20 Weight: 206 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 9-11: 2x4 SPF-S Stud OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 5-14 REACTIONS.All bearings 12-11-0. (lb) - Max Horz 17=-189(LC 6) Max Uplift All uplift 100 lb or less at joint(s) 15, 13 except 17=-105(LC 6), 11=-104(LC 7), 16=-162(LC 10), 12=-174(LC 11) Max Grav All reactions 250 lb or less at joint(s) 17, 15, 13, 12 except 11=258(LC 17), 14=266(LC 10), 16=269(LC 17) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 4-5=-229/270, 5-6=-229/270 WEBS 5-14=-342/221 NOTES-(11-12) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Corner(3E) 0-1-3 to 3-1-3, Exterior(2N) 3-1-3 to 3-5-8, Corner(3R) 3-5-8 to 9-5-8, Exterior(2N) 9-5-8 to 10-11-0, Corner(3E) 10-11-0 to 13-11-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Gable requires continuous bottom chord bearing. 5) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 6) Gable studs spaced at 2-0-0 oc. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 15, 13 except (jt=lb) 17=105, 11=104, 16=162, 12=174. 10) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 11) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 12) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). June 25,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 2_HERITAGE_AT_SPRING~L Truss J01 Truss Type Jack-Open Qty 30 Ply 1 2 Heritage at Spring Mill Job Reference (optional) I41794848 8.240 s Mar 9 2020 MiTek Industries, Inc. Wed Jun 24 18:32:08 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:EvWg2tiHQVSzJMSEDMv2ODzW2H3-6MNEyudQpkL?pGcZ9zF6l9PXn199GbFVUE1gWjz3_c5 Scale = 1:34.6 1 2 5 4 3 3x4 5x6 3x4 4-0-0 4-0-0 -1-0-0 1-0-0 4-0-0 4-0-0 1-7-06-3-05-7-146-3-014.00 12 Plate Offsets (X,Y)-- [2:Edge,0-2-7] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.27 0.15 0.05 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.01 -0.03 -0.00 (loc) 4-5 4-5 3 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 18 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 4-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 6-0-0 oc bracing. REACTIONS. (size)5=0-3-8, 3=Mechanical, 4=Mechanical Max Horz 5=143(LC 10) Max Uplift 3=-97(LC 10), 4=-28(LC 10) Max Grav 5=230(LC 1), 3=124(LC 17), 4=78(LC 3) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(7-8) 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3, 4. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). June 25,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 2_HERITAGE_AT_SPRING~L Truss J02 Truss Type Jack-Open Qty 1 Ply 1 2 Heritage at Spring Mill Job Reference (optional) I41794849 8.240 s Mar 9 2020 MiTek Industries, Inc. Wed Jun 24 18:32:08 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:EvWg2tiHQVSzJMSEDMv2ODzW2H3-6MNEyudQpkL?pGcZ9zF6l9PXu19MGb0VUE1gWjz3_c5 Scale = 1:21.8 1 2 6 5 3 4 3x4 3x4 3x4 1-11-13 1-11-13 4-0-0 2-0-3 -0-11-0 0-11-0 1-11-13 1-11-13 4-0-0 2-0-3 1-1-03-9-02-11-143-3-130-9-28.00 12 6.00 12 Plate Offsets (X,Y)-- [2:0-2-0,0-1-4], [6:0-1-3,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.27 0.13 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in 0.02 -0.02 -0.03 (loc) 5 5 3 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 12 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 4-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 6-0-0 oc bracing. REACTIONS. (size)6=0-5-8, 3=Mechanical, 4=Mechanical Max Horz 6=78(LC 10) Max Uplift 3=-58(LC 10) Max Grav 6=223(LC 1), 3=109(LC 17), 4=74(LC 3) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(8-9) 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Bearing at joint(s) 6 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). June 25,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 2_HERITAGE_AT_SPRING~L Truss J03 Truss Type Jack-Open Qty 1 Ply 1 2 Heritage at Spring Mill Job Reference (optional) I41794850 8.240 s Mar 9 2020 MiTek Industries, Inc. Wed Jun 24 18:32:09 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:EvWg2tiHQVSzJMSEDMv2ODzW2H3-aZxc9Ee2a1TsQPBmihmLHNyifQVK?2GfjumD39z3_c4 Scale = 1:21.8 1 2 5 3 4 3x4 3x4 3-11-13 3-11-13 -0-11-0 0-11-0 4-0-0 4-0-0 1-1-03-9-01-11-123-3-131-9-48.00 12 6.00 12 Plate Offsets (X,Y)-- [2:0-2-0,0-1-4], [5:0-1-3,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.27 0.15 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in 0.02 -0.03 -0.03 (loc) 4-5 4-5 3 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 13 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 4-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 6-0-0 oc bracing. REACTIONS. (size)5=0-5-8, 3=Mechanical, 4=Mechanical Max Horz 5=78(LC 10) Max Uplift 3=-58(LC 10) Max Grav 5=223(LC 1), 3=109(LC 17), 4=74(LC 3) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(8-9) 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Bearing at joint(s) 5 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). June 25,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 2_HERITAGE_AT_SPRING~L Truss J04 Truss Type Jack-Open Qty 6 Ply 1 2 Heritage at Spring Mill Job Reference (optional) I41794851 8.240 s Mar 9 2020 MiTek Industries, Inc. Wed Jun 24 18:32:09 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:EvWg2tiHQVSzJMSEDMv2ODzW2H3-aZxc9Ee2a1TsQPBmihmLHNyifQVK?2GfjumD39z3_c4 Scale = 1:21.8 1 2 5 3 4 3x4 3x4 -0-11-0 0-11-0 4-0-0 4-0-0 1-1-03-9-01-11-123-3-131-9-48.00 12 6.00 12 Plate Offsets (X,Y)-- [2:0-2-0,0-1-4], [5:0-1-3,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.27 0.15 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in 0.02 -0.03 -0.03 (loc) 4-5 4-5 3 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 13 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 4-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 6-0-0 oc bracing. REACTIONS. (size)5=0-5-8, 3=Mechanical, 4=Mechanical Max Horz 5=78(LC 10) Max Uplift 3=-58(LC 10) Max Grav 5=223(LC 1), 3=109(LC 17), 4=74(LC 3) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(8-9) 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Bearing at joint(s) 5 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). June 25,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 2_HERITAGE_AT_SPRING~L Truss J05 Truss Type Jack-Open Qty 1 Ply 1 2 Heritage at Spring Mill Job Reference (optional) I41794852 8.240 s Mar 9 2020 MiTek Industries, Inc. Wed Jun 24 18:32:10 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:EvWg2tiHQVSzJMSEDMv2ODzW2H3-2lV_MZfgLLbj2ZlyGOHaqaUtOqqqkVWoxYWmbbz3_c3 Scale = 1:21.8 1 2 6 5 3 4 3x4 3x4 3x4 1-8-2 1-8-2 4-0-0 2-3-14 -0-11-0 0-11-0 1-8-2 1-8-2 4-0-0 2-3-14 1-1-03-9-03-1-113-3-130-7-58.00 12 6.00 12 Plate Offsets (X,Y)-- [2:0-2-0,0-1-4], [6:0-1-3,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.27 0.13 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in 0.02 -0.02 -0.03 (loc) 5 5 3 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 12 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 4-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 6-0-0 oc bracing. REACTIONS. (size)6=0-5-8, 3=Mechanical, 4=Mechanical Max Horz 6=78(LC 10) Max Uplift 3=-58(LC 10) Max Grav 6=223(LC 1), 3=109(LC 17), 4=74(LC 3) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(8-9) 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Bearing at joint(s) 6 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). June 25,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 2_HERITAGE_AT_SPRING~L Truss J06 Truss Type JACK-OPEN Qty 1 Ply 1 2 Heritage at Spring Mill Job Reference (optional) I41794853 8.240 s Mar 9 2020 MiTek Industries, Inc. Wed Jun 24 18:32:11 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:EvWg2tiHQVSzJMSEDMv2ODzW2H3-Xx3MavfI6fjagjK8q6opMo10IEAKTymyACFK72z3_c2 Scale = 1:21.5 1 2 5 6 3 4 3x4 3x6 -1-8-14 1-8-14 3-7-10 3-7-10 1-7-03-8-40-4-153-3-52-11-80-8-126.95 12 2.98 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.39 0.18 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.01 -0.01 -0.04 (loc) 4-5 4-5 3 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 13 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 3-7-10 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 6-0-0 oc bracing. REACTIONS. (size)5=0-8-7, 3=Mechanical, 4=Mechanical Max Horz 5=67(LC 10) Max Uplift 3=-47(LC 10) Max Grav 5=281(LC 1), 3=83(LC 17), 4=64(LC 3) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(8-9) 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Corner(3) -1-8-14 to 2-6-1, Exterior(2R) 2-6-1 to 3-6-14 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Bearing at joint(s) 5 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). June 25,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 2_HERITAGE_AT_SPRING~L Truss J07 Truss Type JACK-OPEN Qty 1 Ply 1 2 Heritage at Spring Mill Job Reference (optional) I41794854 8.240 s Mar 9 2020 MiTek Industries, Inc. Wed Jun 24 18:32:11 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:EvWg2tiHQVSzJMSEDMv2ODzW2H3-Xx3MavfI6fjagjK8q6opMo1zOE9zTymyACFK72z3_c2 Scale = 1:21.6 1 2 5 6 3 4 3x12 4x6 -2-5-11 2-5-11 2-11-6 2-11-6 1-11-123-8-43-1-93-3-50-6-116.95 12 2.98 12 Plate Offsets (X,Y)-- [2:0-3-0,Edge], [5:Edge,0-0-10] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.64 0.20 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in 0.01 -0.01 -0.05 (loc) 4-5 4-5 3 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 12 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 2-11-6 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 6-0-0 oc bracing. REACTIONS. (size)5=0-8-7, 3=Mechanical, 4=Mechanical Max Horz 5=71(LC 7) Max Uplift 3=-37(LC 10), 4=-5(LC 10) Max Grav 5=342(LC 1), 3=35(LC 17), 4=48(LC 3) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-5=-301/166 NOTES-(8-9) 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Corner(3) -2-5-11 to 1-9-4, Exterior(2R) 1-9-4 to 2-10-10 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Bearing at joint(s) 5 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3, 4. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). June 25,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 2_HERITAGE_AT_SPRING~L Truss J08 Truss Type JACK-OPEN Qty 1 Ply 1 2 Heritage at Spring Mill Job Reference (optional) I41794855 8.240 s Mar 9 2020 MiTek Industries, Inc. Wed Jun 24 18:32:12 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:EvWg2tiHQVSzJMSEDMv2ODzW2H3-?7dknFgwtyrRHtvLOpK2v?ZEEeYNCP05Ps?tfUz3_c1 Scale = 1:15.0 1 2 5 3 4 3x4 3x4 2-9-15 2-9-15 -1-2-13 1-2-13 2-9-15 2-9-15 1-1-02-5-00-4-92-0-72-5-05.66 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.18 0.06 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 -0.00 -0.01 (loc) 4-5 4-5 3 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 9 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 2-9-15 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS. (size)5=0-4-9, 3=Mechanical, 4=Mechanical Max Horz 5=43(LC 7) Max Uplift 5=-5(LC 10), 3=-29(LC 10) Max Grav 5=209(LC 1), 3=59(LC 1), 4=48(LC 3) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(7-8) 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Corner(3) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 3. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). June 25,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 2_HERITAGE_AT_SPRING~L Truss J09 Truss Type JACK-OPEN Qty 1 Ply 1 2 Heritage at Spring Mill Job Reference (optional) I41794856 8.240 s Mar 9 2020 MiTek Industries, Inc. Wed Jun 24 18:32:12 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:EvWg2tiHQVSzJMSEDMv2ODzW2H3-?7dknFgwtyrRHtvLOpK2v?ZEEeYNCP05Ps?tfUz3_c1 Scale = 1:15.0 1 2 5 3 4 3x4 3x4 2-9-15 2-9-15 -1-2-13 1-2-13 2-9-15 2-9-15 1-1-02-5-00-4-92-0-72-5-05.66 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.18 0.06 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 -0.00 -0.01 (loc) 4-5 4-5 3 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 9 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 2-9-15 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS. (size)5=0-4-9, 3=Mechanical, 4=Mechanical Max Horz 5=43(LC 7) Max Uplift 5=-5(LC 10), 3=-29(LC 10) Max Grav 5=209(LC 1), 3=59(LC 1), 4=48(LC 3) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(7-8) 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Corner(3) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 3. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). June 25,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 2_HERITAGE_AT_SPRING~L Truss J10 Truss Type Jack-Open Qty 2 Ply 1 2 Heritage at Spring Mill Job Reference (optional) I41794857 8.240 s Mar 9 2020 MiTek Industries, Inc. Wed Jun 24 18:32:13 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:EvWg2tiHQVSzJMSEDMv2ODzW2H3-TKB7?bhZeGzIv1UXxXrHRD6PX1ufxsFEdWkRCwz3_c0 Scale = 1:15.1 1 2 5 3 43x4 3x4 2-0-0 2-0-0 -0-11-0 0-11-0 2-0-0 2-0-0 1-1-02-5-01-11-132-5-08.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.15 0.06 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 -0.00 -0.00 (loc) 5 4-5 3 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 7 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 2-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS. (size)5=0-3-8, 3=Mechanical, 4=Mechanical Max Horz 5=43(LC 10) Max Uplift 3=-29(LC 10), 4=-1(LC 10) Max Grav 5=156(LC 1), 3=45(LC 17), 4=34(LC 3) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(7-8) 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3, 4. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). June 25,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 2_HERITAGE_AT_SPRING~L Truss J11 Truss Type JACK-OPEN Qty 1 Ply 1 2 Heritage at Spring Mill Job Reference (optional) I41794858 8.240 s Mar 9 2020 MiTek Industries, Inc. Wed Jun 24 18:32:13 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:EvWg2tiHQVSzJMSEDMv2ODzW2H3-TKB7?bhZeGzIv1UXxXrHRD6NA1tKxsFEdWkRCwz3_c0 Scale = 1:15.0 1 2 4 6 3 5 3x4 3x4 1-4-6 1-3-12 -1-8-14 1-8-14 1-4-6 1-4-6 1-7-02-4-86.95 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.30 0.08 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 -0.00 -0.01 (loc) 6 6 3 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 7 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 1-4-6 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS. (size)5=Mechanical, 3=Mechanical, 6=0-5-12 Max Horz 6=44(LC 7) Max Uplift 5=-13(LC 7), 3=-45(LC 1), 6=-4(LC 10) Max Grav 5=22(LC 8), 3=7(LC 6), 6=253(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(7-8) 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Corner(3) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 3, 6. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). June 25,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 2_HERITAGE_AT_SPRING~L Truss J12 Truss Type JACK-OPEN Qty 1 Ply 1 2 Heritage at Spring Mill Job Reference (optional) I41794859 8.240 s Mar 9 2020 MiTek Industries, Inc. Wed Jun 24 18:32:14 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:EvWg2tiHQVSzJMSEDMv2ODzW2H3-xWkVCxiBPa59XB3jVEMW_QfYvRDZgJVOsAU_kMz3_c? Scale = 1:15.0 1 2 4 6 3 5 3x4 3x4 1-4-6 1-3-12 -1-8-14 1-8-14 1-4-6 1-4-6 1-7-02-4-86.95 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.30 0.08 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 -0.00 -0.01 (loc) 6 6 3 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 7 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 1-4-6 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS. (size)5=Mechanical, 3=Mechanical, 6=0-5-12 Max Horz 6=44(LC 7) Max Uplift 5=-13(LC 7), 3=-44(LC 1), 6=-4(LC 10) Max Grav 5=22(LC 8), 3=7(LC 6), 6=253(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(7-8) 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Corner(3) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 3, 6. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). June 25,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 2_HERITAGE_AT_SPRING~L Truss J26 Truss Type Jack-Open Qty 4 Ply 1 2 Heritage at Spring Mill Job Reference (optional) I41794860 8.240 s Mar 9 2020 MiTek Industries, Inc. Wed Jun 24 18:32:14 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:EvWg2tiHQVSzJMSEDMv2ODzW2H3-xWkVCxiBPa59XB3jVEMW_QfaMRDogJVOsAU_kMz3_c? Scale: 3/4"=1' 1 2 5 3 4 3x4 3x4 0-10-0 0-10-0 -0-11-0 0-11-0 0-10-0 0-10-0 1-7-02-6-111-11-92-6-1114.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.14 0.07 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 -0.00 -0.01 (loc) 5 5 3 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 6 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 0-10-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS. (size)5=0-5-8, 3=Mechanical, 4=Mechanical Max Horz 5=47(LC 7) Max Uplift 3=-31(LC 10), 4=-38(LC 10) Max Grav 5=141(LC 1), 3=16(LC 8), 4=39(LC 8) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(7-8) 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3, 4. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). June 25,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 2_HERITAGE_AT_SPRING~L Truss J27 Truss Type JACK-OPEN Qty 1 Ply 1 2 Heritage at Spring Mill Job Reference (optional) I41794861 8.240 s Mar 9 2020 MiTek Industries, Inc. Wed Jun 24 18:32:15 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:EvWg2tiHQVSzJMSEDMv2ODzW2H3-PiItQHipAtD08Kev3ytlXeBiMrYwPmlX5qDXGpz3_c_ Scale: 3/4"=1' 1 2 5 3 4 3x4 3x6 1-2-2 1-1-12 -1-2-13 1-2-13 1-2-2 1-2-2 1-7-02-6-102-0-142-6-109.90 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.38 0.14 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 -0.00 -0.01 (loc) 5 5 3 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 6 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 1-2-2 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS. (size)5=0-7-0, 3=Mechanical, 4=Mechanical Max Horz 5=47(LC 7) Max Uplift 3=-24(LC 10), 4=-21(LC 7) Max Grav 5=180(LC 1), 3=11(LC 8), 4=28(LC 8) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(7-8) 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Corner(3) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3, 4. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). June 25,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 2_HERITAGE_AT_SPRING~L Truss J28 Truss Type JACK-OPEN Qty 1 Ply 1 2 Heritage at Spring Mill Job Reference (optional) I41794862 8.240 s Mar 9 2020 MiTek Industries, Inc. Wed Jun 24 18:32:16 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:EvWg2tiHQVSzJMSEDMv2ODzW2H3-tvsFddjRwBLtmUD6dfO_3rkt6Ft98D?hKUz5nFz3_bz Scale: 3/4"=1' 1 2 5 3 4 3x4 3x6 1-2-2 1-2-2 -1-2-13 1-2-13 1-2-2 1-2-2 1-7-02-6-100-5-122-0-142-6-109.90 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.38 0.14 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 -0.00 -0.01 (loc) 5 5 3 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 6 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 1-2-2 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS. (size)5=0-7-6, 3=Mechanical, 4=Mechanical Max Horz 5=47(LC 7) Max Uplift 3=-24(LC 10), 4=-21(LC 7) Max Grav 5=180(LC 1), 3=11(LC 8), 4=28(LC 8) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(7-8) 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Corner(3) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3, 4. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). June 25,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 2_HERITAGE_AT_SPRING~L Truss J29 Truss Type Jack-Closed Qty 1 Ply 1 2 Heritage at Spring Mill Job Reference (optional) I41794863 8.240 s Mar 9 2020 MiTek Industries, Inc. Wed Jun 24 18:32:16 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:EvWg2tiHQVSzJMSEDMv2ODzW2H3-tvsFddjRwBLtmUD6dfO_3rkqyFqd8CzhKUz5nFz3_bz Scale = 1:32.4 1 2 3 5 4 3x4 3x4 3x4 3x4 6-1-4 6-1-4 -1-5-8 1-5-8 6-1-4 6-1-4 1-3-145-4-112-5-132-9-22-10-148.00 12 6.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.52 0.36 0.07 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.08 -0.16 -0.00 (loc) 4-5 4-5 4 l/defl >873 >436 n/a L/d 240 180 n/a PLATES MT20 Weight: 26 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS. (size)5=0-3-8, 4=Mechanical Max Horz 5=116(LC 7) Max Uplift 4=-49(LC 10) Max Grav 5=342(LC 1), 4=242(LC 17) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-5=-283/177 NOTES-(8-9) 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Bearing at joint(s) 5 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). June 25,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 2_HERITAGE_AT_SPRING~L Truss M01 Truss Type Monopitch Qty 3 Ply 1 2 Heritage at Spring Mill Job Reference (optional) I41794864 8.240 s Mar 9 2020 MiTek Industries, Inc. Wed Jun 24 18:32:17 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:EvWg2tiHQVSzJMSEDMv2ODzW2H3-L5Qdrzk3hVTkOeoIAMvDc3H6xfFttgFqY8ieKhz3_by Scale = 1:16.8 1 2 3 5 4 3x4 3x4 3x4 3x4 2-6-0 2-6-0 -0-11-0 0-11-0 2-6-0 2-6-0 1-1-02-9-08.00 12 Plate Offsets (X,Y)-- [4:Edge,0-2-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.12 0.04 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 -0.00 -0.00 (loc) 5 4-5 4 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 10 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 2-5: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 2-6-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS. (size)4=Mechanical, 5=0-3-8 Max Horz 5=72(LC 7) Max Uplift 4=-26(LC 7), 5=-5(LC 10) Max Grav 4=91(LC 17), 5=169(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(7-8) 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4, 5. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). June 25,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 2_HERITAGE_AT_SPRING~L Truss M02 Truss Type Monopitch Qty 3 Ply 1 2 Heritage at Spring Mill Job Reference (optional) I41794865 8.240 s Mar 9 2020 MiTek Industries, Inc. Wed Jun 24 18:32:17 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:EvWg2tiHQVSzJMSEDMv2ODzW2H3-L5Qdrzk3hVTkOeoIAMvDc3H3sfEetgFqY8ieKhz3_by Scale: 1"=1' 1 2 3 5 4 3x4 3x4 3x6 4-8-8 4-8-8 -0-1-8 0-1-8 4-8-8 4-8-8 0-8-01-10-23.00 12 Plate Offsets (X,Y)-- [4:Edge,0-2-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.32 0.12 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.01 -0.02 0.00 (loc) 4-5 4-5 4 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 12 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 2-5: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 4-8-8 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS. (size)4=Mechanical, 5=0-3-8 Max Horz 5=44(LC 7) Max Uplift 4=-12(LC 10), 5=-9(LC 6) Max Grav 4=178(LC 1), 5=184(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(7-8) 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4, 5. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). June 25,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 2_HERITAGE_AT_SPRING~L Truss PB01 Truss Type GABLE Qty 8 Ply 1 2 Heritage at Spring Mill Job Reference (optional) I41794866 8.240 s Mar 9 2020 MiTek Industries, Inc. Wed Jun 24 18:32:18 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:EvWg2tiHQVSzJMSEDMv2ODzW2H3-pH_02JlhSobb?oNUk4QS8GpHP2b8c7J_noSCs8z3_bx Scale = 1:21.6 2 3 4 6 1 5 4x6 3x4 3x4 2x4 5-4-11 5-4-11 2-8-6 2-8-6 5-4-11 2-8-6 -0-0-43-1-83-1-120-1-00-1-814.00 12 Plate Offsets (X,Y)-- [3:Edge,0-1-14] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.07 0.04 0.01 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 4 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 16 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 5-4-11 oc purlins. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 5-4-11. (lb) - Max Horz 1=54(LC 7) Max Uplift All uplift 100 lb or less at joint(s) except 1=-151(LC 17), 5=-117(LC 18), 2=-142(LC 10), 4=-118(LC 11) Max Grav All reactions 250 lb or less at joint(s) 1, 5, 4, 6 except 2=277(LC 17) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(12-13) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Corner(3E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Gable requires continuous bottom chord bearing. 5) Gable studs spaced at 4-0-0 oc. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Bearing at joint(s) 1, 5, 2, 4 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 151 lb uplift at joint 1, 117 lb uplift at joint 5, 142 lb uplift at joint 2 and 118 lb uplift at joint 4. 10) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 11) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building designer. 12) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 13) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). June 25,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 2_HERITAGE_AT_SPRING~L Truss PB02 Truss Type GABLE Qty 6 Ply 1 2 Heritage at Spring Mill Job Reference (optional) I41794867 8.240 s Mar 9 2020 MiTek Industries, Inc. Wed Jun 24 18:32:19 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:EvWg2tiHQVSzJMSEDMv2ODzW2H3-IUYOFemJD6kSdyyhInyhhUMS?SxBLaT70RBlOaz3_bw Scale = 1:15.5 2 3 4 6 1 5 4x6 3x4 3x4 2x4 6-6-0 6-6-0 3-3-0 3-3-0 6-6-0 3-3-0 -0-0-42-1-122-2-00-1-00-1-88.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.08 0.05 0.02 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 16 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 6-6-0. (lb) - Max Horz 1=-35(LC 6) Max Uplift All uplift 100 lb or less at joint(s) 1, 5, 2, 4 Max Grav All reactions 250 lb or less at joint(s) 1, 5, 2, 4, 6 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(11-12) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Corner(3E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Gable requires continuous bottom chord bearing. 5) Gable studs spaced at 4-0-0 oc. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 5, 2, 4. 9) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 10) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building designer. 11) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 12) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). June 25,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 2_HERITAGE_AT_SPRING~L Truss PB03 Truss Type GABLE Qty 6 Ply 1 2 Heritage at Spring Mill Job Reference (optional) I41794868 8.240 s Mar 9 2020 MiTek Industries, Inc. Wed Jun 24 18:32:20 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:EvWg2tiHQVSzJMSEDMv2ODzW2H3-mg6mT_my_QsIF6WtsVTwEhvdPsG541_GE5xIw0z3_bv Scale = 1:15.0 2 3 4 1 3x4 3x4 3x4 3-8-0 3-8-0-0-0-42-5-52-5-12-3-130-1-88.00 12 Plate Offsets (X,Y)-- [4:Edge,0-2-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.11 0.07 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a -0.00 (loc) - - 4 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 10 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 3-8-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=3-8-0, 4=3-8-0, 2=3-8-0 Max Horz 1=56(LC 7) Max Uplift 1=-119(LC 17), 4=-6(LC 10), 2=-81(LC 10) Max Grav 1=75(LC 10), 4=99(LC 17), 2=274(LC 17) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(11-12) 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Corner(3E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) Gable requires continuous bottom chord bearing. 4) Gable studs spaced at 4-0-0 oc. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Bearing at joint(s) 1, 2 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4, 2 except (jt=lb) 1=119. 9) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 10) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building designer. 11) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 12) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). June 25,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 2_HERITAGE_AT_SPRING~L Truss PB04 Truss Type GABLE Qty 2 Ply 1 2 Heritage at Spring Mill Job Reference (optional) I41794869 8.240 s Mar 9 2020 MiTek Industries, Inc. Wed Jun 24 18:32:21 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:EvWg2tiHQVSzJMSEDMv2ODzW2H3-Esg8gKnalj_9tF53PC_9mvRnjGbJpUEQTlgsTSz3_bu Scale = 1:13.4 2 3 4 5 1 6 3x4 3x4 3x4 3x4 6-6-0 6-6-0 6-6-0 6-6-0 -0-0-41-9-101-9-140-1-00-1-81-8-68.00 12 Plate Offsets (X,Y)-- [3:0-2-0,0-2-3], [4:0-2-0,0-2-3] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.13 0.14 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 6 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 14 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except 2-0-0 oc purlins (6-0-0 max.): 3-4. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=6-6-0, 6=6-6-0, 2=6-6-0, 5=6-6-0 Max Horz 1=29(LC 7) Max Uplift 1=-156(LC 3), 6=-156(LC 3) Max Grav 2=345(LC 1), 5=345(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(13-14) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Corner(3E) 0-3-11 to 2-8-13, Corner(3R) 2-8-13 to 3-9-3, Corner(3E) 3-9-3 to 6-2-5 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Provide adequate drainage to prevent water ponding. 5) Gable requires continuous bottom chord bearing. 6) Gable studs spaced at 4-0-0 oc. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 1=156, 6=156. 10) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 11) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building designer. 12) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 13) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 14) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). June 25,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 2_HERITAGE_AT_SPRING~L Truss PB05 Truss Type GABLE Qty 1 Ply 1 2 Heritage at Spring Mill Job Reference (optional) I41794870 8.240 s Mar 9 2020 MiTek Industries, Inc. Wed Jun 24 18:32:22 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:EvWg2tiHQVSzJMSEDMv2ODzW2H3-i3DWugoCW160UPgGzwVOJ6_wVgxJYwrZiPQP?vz3_bt Scale = 1:22.2 2 3 4 6 1 7 8 5 4x6 3x4 3x4 2x4 10-2-0 10-2-0 5-1-0 5-1-0 10-2-0 5-1-0 -0-0-43-4-73-4-110-1-00-1-88.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.26 0.15 0.04 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 26 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 10-2-0. (lb) - Max Horz 1=57(LC 7) Max Uplift All uplift 100 lb or less at joint(s) except 1=-308(LC 17), 5=-284(LC 18), 2=-190(LC 10), 4=-176(LC 11) Max Grav All reactions 250 lb or less at joint(s) 1, 5 except 2=536(LC 17), 4=527(LC 1), 6=271(LC 3) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(11-12) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Corner(3E) 0-3-11 to 3-3-11, Corner(3R) 3-3-11 to 6-10-5, Corner(3E) 6-10-5 to 9-10-5 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Gable requires continuous bottom chord bearing. 5) Gable studs spaced at 4-0-0 oc. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 308 lb uplift at joint 1, 284 lb uplift at joint 5, 190 lb uplift at joint 2 and 176 lb uplift at joint 4. 9) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 10) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building designer. 11) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 12) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). June 25,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 2_HERITAGE_AT_SPRING~L Truss PB08 Truss Type GABLE Qty 1 Ply 1 2 Heritage at Spring Mill Job Reference (optional) I41794871 8.240 s Mar 9 2020 MiTek Industries, Inc. Wed Jun 24 18:32:23 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:EvWg2tiHQVSzJMSEDMv2ODzW2H3-AFnv50pqHLEt6ZFSXd0drKX5l3GoHM8jx39zXLz3_bs Scale = 1:42.5 2 3 4 5 6 7 8 9 16 15 14 13 12 11 10 1 17 18 3x6 3x4 3x4 3x4 3x6 2x4 4x6 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 24-10-2 24-10-2 6-7-2 6-7-2 21-7-8 15-0-6 24-10-2 3-2-10 4-4-122-3-02-1-80-1-84-3-48.00 12 Plate Offsets (X,Y)-- [4:0-3-0,0-0-2], [8:0-3-12,0-2-0], [10:Edge,0-2-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.29 0.14 0.10 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 10 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 74 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 4-8. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 24-10-2. (lb) - Max Horz 1=93(LC 7) Max Uplift All uplift 100 lb or less at joint(s) 10, 12, 13, 14, 16 except 1=-374(LC 17), 2=-110(LC 10) Max Grav All reactions 250 lb or less at joint(s) 1, 10 except 2=623(LC 17), 11=341(LC 2), 12=414(LC 25), 13=402(LC 2), 14=395(LC 26), 16=434(LC 17) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 7-12=-251/71, 3-16=-267/79 NOTES-(13-14) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Corner(3E) 0-3-5 to 3-3-5, Exterior(2N) 3-3-5 to 3-7-2, Corner(3R) 3-7-2 to 9-7-8, Exterior(2N) 9-7-8 to 18-7-8, Corner(3R) 18-7-8 to 21-7-8, Corner(3E) 21-7-8 to 24-8-14 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Provide adequate drainage to prevent water ponding. 5) Gable requires continuous bottom chord bearing. 6) Gable studs spaced at 4-0-0 oc. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 10, 12, 13, 14, 16 except (jt=lb) 1=374, 2=110. 10) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 11) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building designer. 12) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 13) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 14) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). June 25,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 2_HERITAGE_AT_SPRING~L Truss PB09 Truss Type GABLE Qty 1 Ply 1 2 Heritage at Spring Mill Job Reference (optional) I41794872 8.240 s Mar 9 2020 MiTek Industries, Inc. Wed Jun 24 18:32:24 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:EvWg2tiHQVSzJMSEDMv2ODzW2H3-eRLHJMpS2eMkkjqe5KXsOX3JVTdW0q_s9jvW3nz3_br Scale = 1:12.7 2 3 4 5 1 6 3x4 3x4 3x4 3x4 5-4-11 5-4-11 1-6-5 1-6-5 3-10-7 2-4-2 5-4-11 1-6-5 1-9-50-1-40-1-81-7-1314.00 12 Plate Offsets (X,Y)-- [3:0-1-5,Edge], [4:0-1-5,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.10 0.11 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 6 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 13 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 5-4-11 oc purlins, except 2-0-0 oc purlins: 3-4. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=5-4-11, 6=5-4-11, 2=5-4-11, 5=5-4-11 Max Horz 1=-30(LC 6) Max Uplift 1=-149(LC 3), 6=-149(LC 3) Max Grav 2=295(LC 3), 5=295(LC 3) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(13-14) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Corner(3E) 0-2-7 to 1-6-5, Corner(3R) 1-6-5 to 3-10-7, Corner(3E) 3-10-7 to 5-2-5 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Provide adequate drainage to prevent water ponding. 5) Gable requires continuous bottom chord bearing. 6) Gable studs spaced at 4-0-0 oc. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 1=149, 6=149. 10) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 11) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building designer. 12) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 13) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 14) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). June 25,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 2_HERITAGE_AT_SPRING~L Truss PB10 Truss Type GABLE Qty 1 Ply 1 2 Heritage at Spring Mill Job Reference (optional) I41794873 8.240 s Mar 9 2020 MiTek Industries, Inc. Wed Jun 24 18:32:25 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:EvWg2tiHQVSzJMSEDMv2ODzW2H3-6evfWiq4pyUbLtPqe235xlcUft_nlH0?ONe3cEz3_bq Scale = 1:22.0 2 3 4 6 1 5 4x6 3x4 3x4 2x4 5-4-11 5-4-11 2-8-6 2-8-6 5-4-11 2-8-6 3-1-120-1-40-1-814.00 12 Plate Offsets (X,Y)-- [3:Edge,0-1-14] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.07 0.04 0.01 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 4 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 16 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 5-4-11 oc purlins. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 5-4-11. (lb) - Max Horz 1=54(LC 7) Max Uplift All uplift 100 lb or less at joint(s) except 1=-142(LC 17), 5=-108(LC 18), 2=-136(LC 10), 4=-111(LC 11) Max Grav All reactions 250 lb or less at joint(s) 1, 5, 4, 6 except 2=271(LC 17) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(12-13) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Corner(3E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Gable requires continuous bottom chord bearing. 5) Gable studs spaced at 4-0-0 oc. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Bearing at joint(s) 1, 5, 2, 4 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 142 lb uplift at joint 1, 108 lb uplift at joint 5, 136 lb uplift at joint 2 and 111 lb uplift at joint 4. 10) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 11) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building designer. 12) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 13) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). June 25,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 2_HERITAGE_AT_SPRING~L Truss T01 Truss Type Hip Qty 1 Ply 1 2 Heritage at Spring Mill Job Reference (optional) I41794874 8.240 s Mar 9 2020 MiTek Industries, Inc. Wed Jun 24 18:32:26 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:EvWg2tiHQVSzJMSEDMv2ODzW2H3-aqT1j2riaGcSz1_1ClaKTy9SqH5EUWP9d1Od8gz3_bp Scale = 1:69.4 1 2 3 4 5 6 7 81413121110 9 15 16 17 18 19 20 21 5x8 5x10 MT18HS 4x6 3x6 3x4 3x6 8x10 6x8 3x8 3x4 3x8 4x8 4x6 4x6 6-8-10 6-8-10 14-9-0 8-0-6 23-10-12 9-1-12 30-0-0 6-1-4 6-8-10 6-8-10 10-8-13 4-0-3 14-9-0 4-0-3 19-3-14 4-6-14 23-10-12 4-6-14 30-0-0 6-1-4 4-1-48-4-1111-5-141-3-142-10-148-4-118.00 12 6.00 12 Plate Offsets (X,Y)-- [1:Edge,0-1-14], [2:0-6-8,0-1-12], [6:0-0-12,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.94 0.99 0.90 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.35 -0.66 0.27 (loc) 10-11 10-11 9 l/defl >999 >541 n/a L/d 240 180 n/a PLATES MT20 MT18HS Weight: 134 lb FT = 20% GRIP 169/123 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 *Except* 9-10: 2x4 SPF 2100F 1.8E WEBS 2x3 SPF No.2 *Except* 1-14: 2x4 SPF-S Stud, 8-9: 2x6 SPF No.2, 6-9: 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 2-9-14 oc purlins, except end verticals, and 2-0-0 oc purlins (5-2-0 max.): 2-4. BOT CHORD Structural wood sheathing directly applied. WEBS 1 Row at midpt 3-13, 6-9 REACTIONS. (size)14=0-3-8, 9=0-3-8 Max Horz 14=-228(LC 6) Max Uplift 9=-2(LC 11) Max Grav 14=1311(LC 2), 9=1327(LC 18) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-1123/77, 2-3=-865/102, 3-4=-1255/81, 4-5=-1569/63, 5-6=-3559/73, 6-8=-684/134, 1-14=-1213/32, 8-9=-541/112 BOT CHORD 11-13=0/1108, 10-11=0/1702, 9-10=0/3313 WEBS 2-13=0/359, 3-13=-591/64, 3-11=-26/395, 4-11=0/620, 5-11=-739/119, 5-10=-57/1906, 6-10=0/370, 1-13=0/945, 6-9=-3302/0 NOTES-(11-12) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) 0-1-12 to 3-1-12, Exterior(2R) 3-1-12 to 18-11-15, Interior(1) 18-11-15 to 26-9-4, Exterior(2E) 26-9-4 to 29-9-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 7) Bearing at joint(s) 9 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 2 lb uplift at joint 9. 9) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 10) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 11) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 12) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). June 25,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 2_HERITAGE_AT_SPRING~L Truss T02 Truss Type PIGGYBACK BASE Qty 4 Ply 1 2 Heritage at Spring Mill Job Reference (optional) I41794875 8.240 s Mar 9 2020 MiTek Industries, Inc. Wed Jun 24 18:32:27 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:EvWg2tiHQVSzJMSEDMv2ODzW2H3-301PxOsLLZkJbAZDmT5Z0AhgLhXMDyOIrh7Ag6z3_bo Scale = 1:73.6 1 2 3 4 5 6 7 81413121110 9 15 16 17 18 19 20 21 22 3x4 5x10 MT18HS 5x10 MT18HS 3x6 3x6 8x10 5x10 MT18HS 3x8 4x6 4x6 4x10 4x8 4x8 5x6 7-5-13 7-5-13 13-11-13 6-6-0 23-10-12 9-10-15 30-0-0 6-1-4 3-10-3 3-10-3 7-5-13 3-7-11 13-11-13 6-6-0 18-11-4 4-11-7 23-10-12 4-11-7 30-0-0 6-1-4 4-1-49-1-212-0-01-3-142-10-149-1-28.00 12 6.00 12 Plate Offsets (X,Y)-- [2:0-2-7,0-2-0], [3:0-6-0,0-1-8], [4:0-6-0,0-1-8], [6:0-1-12,0-1-12], [9:0-2-4,0-1-12], [11:0-2-8,0-2-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.76 0.61 0.98 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.44 -0.80 0.28 (loc) 10-11 10-11 9 l/defl >818 >443 n/a L/d 240 180 n/a PLATES MT20 MT18HS Weight: 139 lb FT = 20% GRIP 169/123 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF 2100F 1.8E *Except* 12-14: 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 4-13,8-9,6-9: 2x4 SPF No.2, 1-14: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 2-8-1 oc purlins, except end verticals, and 2-0-0 oc purlins (5-9-11 max.): 3-4. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 4-13, 5-11, 2-14, 6-9 REACTIONS. (size)9=0-3-8, 14=0-3-8 Max Horz 14=-240(LC 6) Max Uplift 9=-4(LC 11) Max Grav 9=1348(LC 18), 14=1346(LC 2) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-1094/96, 3-4=-886/104, 4-5=-1484/68, 5-6=-3719/78, 6-8=-653/140, 8-9=-522/114 BOT CHORD 13-14=-42/743, 11-13=0/1190, 10-11=0/1666, 9-10=0/3426 WEBS 2-13=-23/457, 3-13=-4/343, 4-13=-569/38, 4-11=0/968, 5-11=-790/129, 5-10=-50/2078, 6-10=0/366, 2-14=-1199/0, 6-9=-3455/0 NOTES-(11-12) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) 0-1-12 to 3-1-12, Exterior(2R) 3-1-12 to 18-2-12, Interior(1) 18-2-12 to 26-10-4, Exterior(2E) 26-10-4 to 29-10-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 7) Bearing at joint(s) 9 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 4 lb uplift at joint 9. 9) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 10) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 11) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 12) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). June 25,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 2_HERITAGE_AT_SPRING~L Truss T03 Truss Type Half Hip Qty 1 Ply 1 2 Heritage at Spring Mill Job Reference (optional) I41794876 8.240 s Mar 9 2020 MiTek Industries, Inc. Wed Jun 24 18:32:28 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:EvWg2tiHQVSzJMSEDMv2ODzW2H3-XCbo8jsz6tsACK8PKAcoYNEpT4smyXvS4LtjDZz3_bn Scale = 1:82.6 1 2 3 4 5 6 7 12 11 10 9 8 13 14 15 16 3x6 12x18 MT18HS 12x18 MT18HS 3x6 5x6 3x4 3x4 3x4 3x6 8-11-12 8-11-12 17-9-0 8-9-4 18-2-8 0-5-8 18-6-0 0-3-8 18-6-8 0-0-8 -1-3-8 1-3-8 8-11-12 8-11-12 17-9-0 8-9-4 18-2-8 0-5-8 18-6-8 0-4-0 1-1-012-8-1112-11-012-5-39-5-412-8-118.00 12 Plate Offsets (X,Y)-- [5:0-1-14,Edge], [8:Edge,0-3-8], [12:Edge,0-10-2], [12:0-1-12,0-0-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.80 0.66 0.45 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.17 -0.31 0.22 (loc) 9-10 9-10 13 l/defl >999 >702 n/a L/d 240 180 n/a PLATES MT20 MT18HS Weight: 104 lb FT = 20% GRIP 197/144 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 *Except* 4-10,2-10: 2x3 SPF No.2 OTHERS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 5-9-4 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 5-7. BOT CHORD Structural wood sheathing directly applied or 6-0-0 oc bracing. WEBS 1 Row at midpt 4-9 REACTIONS. (size)12=0-3-8, 13=0-3-8 Max Horz 12=339(LC 10) Max Uplift 13=-152(LC 10) Max Grav 12=899(LC 17), 13=909(LC 17) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-4=-890/0, 2-12=-757/0 BOT CHORD 8-13=-255/391, 6-13=-594/0, 10-12=-387/640, 9-10=-138/710 WEBS 4-10=0/429, 4-9=-832/164, 2-10=-132/255, 5-9=0/526 NOTES-(12-13) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -1-3-8 to 1-8-8, Interior(1) 1-8-8 to 13-6-1, Exterior(2R) 13-6-1 to 17-9-0, Exterior(2E) 17-9-0 to 18-6-8 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise indicated. 5) The Fabrication Tolerance at joint 5 = 8%, joint 5 = 8% 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 8) Bearing at joint(s) 13 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 152 lb uplift at joint 13. 10) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 11) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 12) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 13) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). June 25,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 2_HERITAGE_AT_SPRING~L Truss T04 Truss Type Piggyback Base Qty 5 Ply 1 2 Heritage at Spring Mill Job Reference (optional) I41794877 8.240 s Mar 9 2020 MiTek Industries, Inc. Wed Jun 24 18:32:29 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:EvWg2tiHQVSzJMSEDMv2ODzW2H3-?P8AM3tbtB_1qUictu715bn?ZUEohz7bJ?cHl?z3_bm Scale: 3/16"=1' 1 2 3 4 5 6 11 10 9 8 7 12 13 14 15 16 3x6 6x8 4x8 4x6 3x6 3x4 3x4 3x4 10x10 6x8 3x6 7-6-8 7-6-8 14-10-8 7-4-0 18-6-8 3-8-0 -1-3-8 1-3-8 7-6-8 7-6-8 14-10-8 7-4-0 18-6-8 3-8-0 1-1-011-0-09-1-1211-0-08.00 12 Plate Offsets (X,Y)-- [2:0-3-8,Edge], [5:0-9-8,0-6-4] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.72 0.48 0.52 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.09 -0.17 -0.07 (loc) 8-9 8-9 13 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 105 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 *Except* 5-6: 2x6 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 *Except* 4-9,4-8,2-9: 2x3 SPF No.2, 2-11: 2x4 SPF-S Stud OTHERS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 5-9-9 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 5-6. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 4-8, 5-7 REACTIONS. (size)11=0-3-8, 13=0-3-8 Max Horz 11=282(LC 7) Max Uplift 13=-56(LC 10) Max Grav 11=903(LC 17), 13=803(LC 17) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-4=-934/0, 4-5=-426/74, 7-12=-65/890, 6-12=-65/890, 2-11=-781/36 BOT CHORD 9-11=-241/517, 8-9=-80/793, 7-8=-68/293 WEBS 4-9=0/332, 4-8=-643/123, 5-8=-36/593, 5-7=-892/84, 2-9=0/377, 6-13=-805/64 NOTES-(10-11) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -1-3-8 to 1-8-8, Interior(1) 1-8-8 to 10-7-9, Exterior(2R) 10-7-9 to 14-10-8, Exterior(2E) 14-10-8 to 18-1-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Bearing at joint(s) 13 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 56 lb uplift at joint 13. 8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 10) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 11) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). June 25,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 2_HERITAGE_AT_SPRING~L Truss T05 Truss Type Half Hip Qty 1 Ply 1 2 Heritage at Spring Mill Job Reference (optional) I41794878 8.240 s Mar 9 2020 MiTek Industries, Inc. Wed Jun 24 18:32:30 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:EvWg2tiHQVSzJMSEDMv2ODzW2H3-TbiYZPuDdU6uSeHoRbeGeoJJGuh7QY_lYfMqHRz3_bl Scale = 1:22.1 1 2 3 4 7 6 5 4x8 3x4 3x4 3x4 3x4 3x6 1-11-0 1-11-0 4-0-0 2-1-0 -0-11-0 0-11-0 1-11-0 1-11-0 4-0-0 2-1-0 1-7-03-8-03-9-133-8-014.00 12 Plate Offsets (X,Y)-- [3:0-5-3,0-2-0], [4:Edge,0-2-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.14 0.03 0.03 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 -0.00 -0.00 (loc) 6 6 5 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 23 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 2-7: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 4-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins: 3-4. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS. (size)5=Mechanical, 7=0-3-8 Max Horz 7=105(LC 7) Max Uplift 5=-46(LC 7) Max Grav 5=141(LC 1), 7=223(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(10-11) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Refer to girder(s) for truss to truss connections. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 46 lb uplift at joint 5. 8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 10) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 11) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). June 25,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 2_HERITAGE_AT_SPRING~L Truss T06 Truss Type Half Hip Qty 1 Ply 1 2 Heritage at Spring Mill Job Reference (optional) I41794879 8.240 s Mar 9 2020 MiTek Industries, Inc. Wed Jun 24 18:32:30 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:EvWg2tiHQVSzJMSEDMv2ODzW2H3-TbiYZPuDdU6uSeHoRbeGeoJJnug5QXBlYfMqHRz3_bl Scale = 1:28.9 1 2 3 4 7 6 5 4x6 3x4 3x4 3x4 3x4 3x4 3-0-11 3-0-11 4-0-0 0-11-5 -0-11-0 0-11-0 3-0-11 3-0-11 4-0-0 0-11-5 1-7-05-0-05-1-135-0-014.00 12 Plate Offsets (X,Y)-- [3:0-3-3,0-2-0], [5:Edge,0-2-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.18 0.09 0.08 DEFL. Vert(LL) Vert(CT) Horz(CT) in 0.01 -0.01 -0.00 (loc) 6-7 6-7 5 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 25 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 2-7: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 4-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins: 3-4. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS. (size)5=Mechanical, 7=0-3-8 Max Horz 7=141(LC 7) Max Uplift 5=-76(LC 7) Max Grav 5=164(LC 17), 7=231(LC 18) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(10-11) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -0-11-0 to 2-1-0, Exterior(2R) 2-1-0 to 3-0-11, Exterior(2E) 3-0-11 to 3-10-12 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Refer to girder(s) for truss to truss connections. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 76 lb uplift at joint 5. 8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 10) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 11) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). June 25,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 2_HERITAGE_AT_SPRING~L Truss T07 Truss Type Piggyback Base Qty 7 Ply 1 2 Heritage at Spring Mill Job Reference (optional) I41794880 8.240 s Mar 9 2020 MiTek Industries, Inc. Wed Jun 24 18:32:31 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:EvWg2tiHQVSzJMSEDMv2ODzW2H3-xnGwnlvrOoEl3os_?J9VA0sNGItD9oNumJ5Optz3_bk Scale = 1:68.1 1 2 3 4 5 6 7 8 13 12 11 10 91415161718 4x6 6x6 3x6 3x8 3x4 3x4 3x4 3x4 5x10 MT18HS 5x10 MT18HS 3x4 8-11-2 8-11-2 14-3-14 5-4-11 23-3-0 8-11-2 -1-0-0 1-0-0 4-6-13 4-6-13 8-11-2 4-4-5 14-3-14 5-4-11 18-8-3 4-4-5 23-3-0 4-6-13 24-3-0 1-0-0 1-7-012-0-01-7-012-0-014.00 12 Plate Offsets (X,Y)-- [4:0-3-2,0-2-0], [5:0-3-0,0-1-8], [9:Edge,0-1-12], [13:Edge,0-1-12] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.58 0.68 0.85 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.21 -0.34 0.02 (loc) 9-10 9-10 9 l/defl >999 >814 n/a L/d 240 180 n/a PLATES MT20 MT18HS Weight: 136 lb FT = 20% GRIP 197/144 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 *Except* 3-11,6-10,3-13,6-9: 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 4-5. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 5-11 REACTIONS. (size)13=0-3-8, 9=0-3-8 Max Horz 13=254(LC 9) Max Grav 13=1107(LC 2), 9=1111(LC 2) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-566/104, 3-4=-864/141, 4-5=-515/137, 5-6=-869/141, 6-7=-566/105, 2-13=-559/100, 7-9=-559/100 BOT CHORD 11-13=-99/675, 10-11=-0/559, 9-10=0/574 WEBS 4-11=-49/381, 5-10=-71/421, 3-13=-588/47, 6-9=-587/48 NOTES-(9-10) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 4-5-12, Exterior(2R) 4-5-12 to 18-9-4, Interior(1) 18-9-4 to 21-3-0, Exterior(2E) 21-3-0 to 24-3-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 9) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 10) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). June 25,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 2_HERITAGE_AT_SPRING~L Truss T08 Truss Type Piggyback Base Qty 1 Ply 1 2 Heritage at Spring Mill Job Reference (optional) I41794881 8.240 s Mar 9 2020 MiTek Industries, Inc. Wed Jun 24 18:32:32 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:EvWg2tiHQVSzJMSEDMv2ODzW2H3-P_qI_5wT96MbhyRBZ0hkjDPY0iDQuFa1?zrxMKz3_bj Scale = 1:68.1 1 2 3 4 5 6 7 12 11 10 9 81314151617 4x6 6x6 3x4 3x6 3x8 3x4 3x4 3x4 3x4 5x10 MT18HS 5x10 MT18HS 8-11-2 8-11-2 14-3-14 5-4-11 23-3-0 8-11-2 -1-0-0 1-0-0 4-6-13 4-6-13 8-11-2 4-4-5 14-3-14 5-4-11 18-8-3 4-4-5 23-3-0 4-6-13 1-7-012-0-01-7-012-0-014.00 12 Plate Offsets (X,Y)-- [4:0-3-2,0-2-0], [5:0-3-0,0-1-8], [8:Edge,0-1-12], [12:Edge,0-1-12] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.58 0.68 0.86 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.21 -0.34 0.02 (loc) 8-9 8-9 8 l/defl >999 >815 n/a L/d 240 180 n/a PLATES MT20 MT18HS Weight: 134 lb FT = 20% GRIP 197/144 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 *Except* 3-10,6-9,3-12,6-8: 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 4-5. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 5-10 REACTIONS. (size)12=0-3-8, 8=0-3-8 Max Horz 12=244(LC 7) Max Grav 12=1109(LC 2), 8=1052(LC 2) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-566/104, 3-4=-866/140, 4-5=-516/136, 5-6=-872/140, 6-7=-590/88, 2-12=-559/100, 7-8=-513/73 BOT CHORD 10-12=-107/664, 9-10=-8/549, 8-9=0/567 WEBS 4-10=-48/382, 5-9=-69/424, 3-12=-590/47, 6-8=-557/57 NOTES-(9-10) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 4-5-12, Exterior(2R) 4-5-12 to 18-9-4, Interior(1) 18-9-4 to 20-1-4, Exterior(2E) 20-1-4 to 23-1-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 9) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 10) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). June 25,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 2_HERITAGE_AT_SPRING~L Truss T09 Truss Type Roof Special Qty 1 Ply 1 2 Heritage at Spring Mill Job Reference (optional) I41794882 8.240 s Mar 9 2020 MiTek Industries, Inc. Wed Jun 24 18:32:33 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:EvWg2tiHQVSzJMSEDMv2ODzW2H3-tAOhBRw5wPUSJ50N6jCzFRxki5gqdqtBEdaUumz3_bi Scale = 1:46.2 1 2 3 6 5 4 7 4x6 5x6 4x6 3x4 3x4 3x4 1-9-11 1-9-11 7-1-8 5-3-13 1-9-11 1-9-11 7-1-8 5-3-13 7-9-71-7-07-9-714.00 12 Plate Offsets (X,Y)-- [2:0-3-2,0-2-0], [4:Edge,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.52 0.22 0.34 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.03 -0.06 0.00 (loc) 4-5 4-5 4 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 39 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 3-4: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 1-2. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS. (size)6=Mechanical, 4=0-3-8 Max Horz 6=-203(LC 6) Max Uplift 6=-101(LC 6) Max Grav 6=367(LC 18), 4=376(LC 17) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-6=-411/126, 2-3=-290/75, 3-4=-263/71 WEBS 1-5=-173/509 NOTES-(9-10) 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) 0-1-4 to 1-9-11, Exterior(2R) 1-9-11 to 3-11-12, Exterior(2E) 3-11-12 to 6-11-12 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Provide adequate drainage to prevent water ponding. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 101 lb uplift at joint 6. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 9) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 10) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). June 25,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 2_HERITAGE_AT_SPRING~L Truss T10 Truss Type Roof Special Qty 1 Ply 1 2 Heritage at Spring Mill Job Reference (optional) I41794883 8.240 s Mar 9 2020 MiTek Industries, Inc. Wed Jun 24 18:32:34 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:EvWg2tiHQVSzJMSEDMv2ODzW2H3-LMy3PnxkhjcJwFbZgRjCoeUzSVuSMH_KSHK2QCz3_bh Scale = 1:58.1 1 2 3 4 5 6 10 9 8 7 11 12 3x4 4x6 6x10 6x10 3x8 3x8 3x6 3x4 3x6 1-8-10 1-8-10 11-2-6 9-5-12 12-11-0 1-8-10 1-8-10 1-8-10 6-5-8 4-8-14 11-2-6 4-8-14 12-11-0 1-8-10 13-11-0 1-0-0 1-7-09-1-71-7-01-0-1314.00 12 9.00 12 Plate Offsets (X,Y)-- [8:0-4-12,Edge], [9:0-4-12,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.26 0.71 0.35 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.29 -0.47 0.07 (loc) 8-9 8-9 7 l/defl >526 >320 n/a L/d 240 180 n/a PLATES MT20 Weight: 66 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 1-10,5-7: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 5-8-3 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS. (size)10=0-3-8, 7=0-3-8 Max Horz 10=-192(LC 6) Max Uplift 10=-4(LC 11), 7=-1(LC 10) Max Grav 10=596(LC 18), 7=649(LC 17) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-1003/190, 3-4=-873/148 BOT CHORD 9-10=-94/986, 8-9=-29/310, 7-8=0/807 WEBS 3-8=-130/605, 4-8=-6/457, 3-9=-167/725, 2-9=0/418, 2-10=-1200/0, 4-7=-1166/0 NOTES-(9-10) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) 0-1-12 to 3-1-12, Interior(1) 3-1-12 to 3-5-8, Exterior(2R) 3-5-8 to 9-5-8, Interior(1) 9-5-8 to 10-11-0, Exterior(2E) 10-11-0 to 13-11-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) The Fabrication Tolerance at joint 9 = 16%, joint 8 = 16% 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Bearing at joint(s) 10, 7 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 4 lb uplift at joint 10 and 1 lb uplift at joint 7. 8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 10) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). June 25,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 2_HERITAGE_AT_SPRING~L Truss T11 Truss Type Common Qty 3 Ply 1 2 Heritage at Spring Mill Job Reference (optional) I41794884 8.240 s Mar 9 2020 MiTek Industries, Inc. Wed Jun 24 18:32:34 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:EvWg2tiHQVSzJMSEDMv2ODzW2H3-LMy3PnxkhjcJwFbZgRjCoeUtIV0fMKHKSHK2QCz3_bh Scale = 1:56.3 1 2 3 4 7 6 5 6x8 4x6 3x4 3x4 3x8 6x8 6-2-8 6-2-8 12-8-0 6-5-8 6-2-8 6-2-8 12-8-0 6-5-8 13-7-0 0-11-0 1-10-89-1-71-7-014.00 12 Plate Offsets (X,Y)-- [1:Edge,0-1-5], [3:Edge,0-1-5] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.65 0.25 0.14 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.03 -0.05 0.00 (loc) 5-6 5-6 5 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 58 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 1-7,3-5: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS. (size)7=Mechanical, 5=0-3-8 Max Horz 7=-191(LC 6) Max Uplift 7=-5(LC 11) Max Grav 7=492(LC 1), 5=561(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-443/82, 2-3=-452/80, 1-7=-431/42, 3-5=-497/53 BOT CHORD 6-7=-194/292 NOTES-(8-9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) 0-1-12 to 3-1-12, Exterior(2R) 3-1-12 to 9-2-8, Interior(1) 9-2-8 to 10-7-0, Exterior(2E) 10-7-0 to 13-7-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 5 lb uplift at joint 7. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). June 25,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 2_HERITAGE_AT_SPRING~L Truss T12 Truss Type Hip Qty 1 Ply 1 2 Heritage at Spring Mill Job Reference (optional) I41794885 8.240 s Mar 9 2020 MiTek Industries, Inc. Wed Jun 24 18:32:35 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:EvWg2tiHQVSzJMSEDMv2ODzW2H3-qZWRc7yMS1lAYPAlE8ERLs054vHx5jlUhx3byfz3_bg Scale = 1:34.1 1 2 3 4 5 6 7 13 12 11 10 9 8 4x8 4x8 3x6 3x4 5x6 5x12 3x4 3x4 3x4 2x4 3x4 3x6 3-0-0 3-0-0 5-11-0 2-11-0 12-4-0 6-5-0 15-7-1 3-3-1 18-3-0 2-7-15 -0-11-0 0-11-0 3-0-0 3-0-0 5-11-0 2-11-0 12-4-0 6-5-0 15-7-1 3-3-1 18-3-0 2-7-15 1-7-04-11-35-1-01-11-122-8-122-2-714.00 12 6.00 12 Plate Offsets (X,Y)-- [3:0-5-3,0-2-0], [6:0-5-3,0-2-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.46 0.50 0.45 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.07 -0.17 0.14 (loc) 10-11 10-11 8 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 75 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 2-13,7-8: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (4-0-10 max.): 3-6. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS. (size)13=0-5-8, 8=0-5-8 Max Horz 13=119(LC 9) Max Grav 13=784(LC 1), 8=716(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-860/82, 3-4=-1551/145, 4-5=-1569/97, 5-6=-1570/98, 6-7=-749/26, 2-13=-761/58, 7-8=-699/14 BOT CHORD 11-12=-114/586, 10-11=-180/1568, 9-10=-38/513 WEBS 3-11=-91/1249, 4-11=-349/108, 5-10=-342/93, 6-10=-113/1296, 6-9=-255/44, 2-12=0/493, 7-9=-29/446 NOTES-(9-10) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -0-11-0 to 2-1-0, Exterior(2R) 2-1-0 to 7-2-15, Interior(1) 7-2-15 to 11-4-3, Exterior(2R) 11-4-3 to 15-7-1, Exterior(2E) 15-7-1 to 18-1-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Bearing at joint(s) 13, 8 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 9) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 10) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). June 25,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 2_HERITAGE_AT_SPRING~L Truss T13 Truss Type Hip Qty 1 Ply 1 2 Heritage at Spring Mill Job Reference (optional) I41794886 8.240 s Mar 9 2020 MiTek Industries, Inc. Wed Jun 24 18:32:36 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:EvWg2tiHQVSzJMSEDMv2ODzW2H3-Il4pqSz_DKt1AZlyoslgt3ZIbJfcqCjdwbp9V5z3_bf Scale = 1:38.9 1 2 3 4 5 6 7 13 12 11 10 9 8 4x8 4x8 3x6 3x4 5x6 5x12 3x4 3x4 3x4 2x4 3x4 4x6 4-1-11 4-1-11 5-11-0 1-9-5 12-4-0 6-5-0 14-5-6 2-1-6 18-3-0 3-9-10 -0-11-0 0-11-0 4-1-11 4-1-11 5-11-0 1-9-5 12-4-0 6-5-0 14-5-6 2-1-6 18-3-0 3-9-10 1-7-06-3-36-5-01-11-122-8-123-6-714.00 12 6.00 12 Plate Offsets (X,Y)-- [2:0-2-8,0-1-8], [3:0-5-3,0-2-0], [6:0-5-3,0-2-0], [7:0-2-8,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.35 0.34 0.27 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.05 -0.11 0.07 (loc) 10-11 10-11 8 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 82 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 2-13,7-8: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 5-11-7 oc purlins, except end verticals, and 2-0-0 oc purlins (5-5-14 max.): 3-6. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS. (size)13=0-5-8, 8=0-5-8 Max Horz 13=144(LC 7) Max Grav 13=784(LC 1), 8=716(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-938/73, 3-4=-921/91, 4-5=-930/41, 5-6=-932/42, 6-7=-850/20, 2-13=-766/53, 7-8=-696/25 BOT CHORD 11-12=-116/626, 10-11=-127/929, 9-10=-28/562 WEBS 3-11=-39/791, 4-11=-357/131, 5-10=-333/99, 6-10=-89/784, 2-12=0/495, 7-9=-32/450 NOTES-(9-10) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -0-11-0 to 2-1-0, Exterior(2R) 2-1-0 to 8-4-10, Interior(1) 8-4-10 to 10-2-7, Exterior(2R) 10-2-7 to 15-1-4, Exterior(2E) 15-1-4 to 18-1-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Bearing at joint(s) 13, 8 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 9) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 10) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). June 25,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 2_HERITAGE_AT_SPRING~L Truss T14 Truss Type Hip Qty 1 Ply 1 2 Heritage at Spring Mill Job Reference (optional) I41794887 8.240 s Mar 9 2020 MiTek Industries, Inc. Wed Jun 24 18:32:37 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:EvWg2tiHQVSzJMSEDMv2ODzW2H3-mxdB1ozc_e?unjK8LZGvQH6SJj0LZhan9FYi1Xz3_be Scale = 1:45.3 1 2 3 4 5 6 10 9 8 7 6x6 5x6 5x8 3x4 6x10 6x8 3x4 3x4 6x8 5-11-0 5-11-0 12-4-0 6-5-0 18-3-0 5-11-0 -0-11-0 0-11-0 5-3-7 5-3-7 9-3-9 4-0-2 13-3-10 4-0-2 18-3-0 4-11-6 1-7-07-7-37-9-01-11-122-8-124-10-714.00 12 6.00 12 Plate Offsets (X,Y)-- [2:Edge,0-1-5], [3:0-4-0,0-3-0], [5:0-3-10,0-2-8], [6:Edge,0-1-5] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.41 0.31 0.17 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.04 -0.08 0.05 (loc) 8-9 8-9 7 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 80 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 2-10,6-7: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 5-7-13 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 3-5. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS. (size)10=0-5-8, 7=0-5-8 Max Horz 10=169(LC 7) Max Grav 10=784(LC 1), 7=716(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-998/52, 3-4=-628/62, 4-5=-624/38, 5-6=-945/17, 2-10=-774/63, 6-7=-698/38 BOT CHORD 9-10=-201/280, 8-9=-88/702 WEBS 3-9=0/413, 5-8=-8/391, 2-9=0/491, 6-8=-52/476 NOTES-(9-10) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -0-11-0 to 2-1-0, Exterior(2R) 2-1-0 to 15-1-4, Exterior(2E) 15-1-4 to 18-1-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Bearing at joint(s) 10, 7 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 9) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 10) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). June 25,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 2_HERITAGE_AT_SPRING~L Truss T15 Truss Type Hip Qty 1 Ply 1 2 Heritage at Spring Mill Job Reference (optional) I41794888 8.240 s Mar 9 2020 MiTek Industries, Inc. Wed Jun 24 18:32:38 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:EvWg2tiHQVSzJMSEDMv2ODzW2H3-E8BaF8_Ely7lPtuKvHn8yUeZA6L5I8uwNvIFZzz3_bd Scale = 1:52.9 1 2 3 4 8 7 6 5 9 10 8x8 6x6 6x6 6x8 3x4 6x6 3x4 6x10 5-11-0 5-11-0 12-4-0 6-5-0 18-3-0 5-11-0 6-5-2 6-5-2 12-1-15 5-8-13 18-3-0 6-1-1 1-7-08-11-39-1-01-11-122-8-126-2-714.00 12 6.00 12 Plate Offsets (X,Y)-- [1:Edge,0-2-12], [2:0-4-0,0-3-0], [3:0-4-4,0-3-4], [4:Edge,0-1-5] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.66 0.34 0.16 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.06 -0.11 0.05 (loc) 6-7 6-7 5 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 80 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 1-8,4-5: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 5-3-9 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 2-3. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 2-6 REACTIONS. (size)8=0-5-8, 5=0-5-8 Max Horz 8=180(LC 9) Max Grav 8=782(LC 2), 5=776(LC 2) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-1061/23, 2-3=-563/67, 3-4=-989/3, 1-8=-809/76, 4-5=-734/51 BOT CHORD 7-8=-233/404, 6-7=-98/647 WEBS 2-7=0/488, 3-6=0/431, 1-7=0/532, 4-6=-54/520 NOTES-(9-10) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) 0-1-12 to 3-1-12, Exterior(2R) 3-1-12 to 15-1-4, Exterior(2E) 15-1-4 to 18-1-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Bearing at joint(s) 8, 5 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 9) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 10) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). June 25,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 2_HERITAGE_AT_SPRING~L Truss T16 Truss Type Hip Qty 1 Ply 1 2 Heritage at Spring Mill Job Reference (optional) I41794889 8.240 s Mar 9 2020 MiTek Industries, Inc. Wed Jun 24 18:32:39 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:EvWg2tiHQVSzJMSEDMv2ODzW2H3-iKlySU?sWFFc10TXT_JNViBkRWiu1U13cZ1p5Qz3_bc Scale = 1:60.3 1 2 3 4 5 6 12 11 10 9 8 7 3x6 4x8 4x6 3x6 5x6 5x6 4x10 3x4 4x8 4x10 4x6 3x6 5-11-0 5-11-0 7-6-14 1-7-14 11-0-3 3-5-6 12-4-0 1-3-13 18-3-0 5-11-0 5-11-0 5-11-0 7-6-14 1-7-14 11-0-3 3-5-6 12-4-0 1-3-13 18-3-0 5-11-0 1-7-010-3-310-5-01-11-122-8-127-6-714.00 12 6.00 12 Plate Offsets (X,Y)-- [3:0-5-3,0-2-0], [4:0-3-3,0-2-0], [12:0-2-13,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.69 0.31 0.62 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.03 -0.07 0.08 (loc) 7-8 11-12 7 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 108 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 1-12,6-7: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 3-4. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 2-12, 5-7 REACTIONS. (size)12=0-5-8, 7=0-5-8 Max Horz 12=205(LC 7) Max Grav 12=718(LC 1), 7=718(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-474/244, 2-3=-729/158, 3-4=-435/77, 4-5=-716/159, 5-6=-404/232, 1-12=-451/209, 6-7=-397/190 BOT CHORD 11-12=-132/681, 10-11=-104/590, 9-10=-69/461, 8-9=-1/508, 7-8=-17/580 WEBS 2-11=0/372, 2-10=-471/217, 3-10=-186/491, 4-9=-134/422, 5-9=-378/199, 5-8=0/346, 2-12=-620/0, 5-7=-664/50 NOTES-(9-10) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) 0-1-12 to 3-1-12, Exterior(2R) 3-1-12 to 15-1-4, Exterior(2E) 15-1-4 to 18-1-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Bearing at joint(s) 12, 7 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 9) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 10) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). June 25,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 2_HERITAGE_AT_SPRING~L Truss T17 Truss Type Hip Qty 1 Ply 1 2 Heritage at Spring Mill Job Reference (optional) I41794890 8.240 s Mar 9 2020 MiTek Industries, Inc. Wed Jun 24 18:32:40 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:EvWg2tiHQVSzJMSEDMv2ODzW2H3-AWJKfq0UHZNTeA2j1iqc2vkvEw2CmwhDrDnMesz3_bb Scale = 1:67.9 1 2 3 4 5 6 12 11 10 9 8 7 3x6 4x8 4x6 3x6 5x6 5x6 3x12 3x4 4x8 4x10 4x6 3x6 5-11-0 5-11-0 8-8-9 2-9-9 9-10-8 1-1-15 12-4-0 2-5-8 18-3-0 5-11-0 5-11-0 5-11-0 8-8-9 2-9-9 9-10-8 1-1-15 12-4-0 2-5-8 18-3-0 5-11-0 1-7-011-7-311-9-01-11-122-8-128-10-714.00 12 6.00 12 Plate Offsets (X,Y)-- [3:0-5-3,0-2-0], [4:0-3-3,0-2-0], [12:0-2-13,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.69 0.30 0.66 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.03 -0.07 0.08 (loc) 7-8 7-8 7 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 113 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 1-12,6-7: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 3-4. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 3-9, 2-12, 5-7 REACTIONS. (size)12=0-5-8, 7=0-5-8 Max Horz 12=230(LC 7) Max Grav 12=718(LC 1), 7=718(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-472/246, 2-3=-657/130, 3-4=-379/95, 4-5=-656/145, 5-6=-413/240, 1-12=-448/212, 6-7=-406/197 BOT CHORD 11-12=-131/730, 10-11=-102/629, 9-10=-49/422, 8-9=0/508, 7-8=-5/587 WEBS 2-11=0/405, 2-10=-465/194, 3-10=-126/375, 4-9=-103/376, 5-9=-369/171, 5-8=0/366, 2-12=-632/0, 5-7=-708/34 NOTES-(9-10) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) 0-1-12 to 3-1-12, Interior(1) 3-1-12 to 4-5-11, Exterior(2R) 4-5-11 to 14-1-7, Interior(1) 14-1-7 to 15-1-4, Exterior(2E) 15-1-4 to 18-1-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Bearing at joint(s) 12, 7 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 9) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 10) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). June 25,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 2_HERITAGE_AT_SPRING~L Truss T18 Truss Type Roof Special Qty 3 Ply 1 2 Heritage at Spring Mill Job Reference (optional) I41794891 8.240 s Mar 9 2020 MiTek Industries, Inc. Wed Jun 24 18:32:41 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:EvWg2tiHQVSzJMSEDMv2ODzW2H3-ejtitA172tVKGKdvaPLra7G4pKOWVMEM3tWvAIz3_ba Scale = 1:77.6 1 2 3 4 5 9 8 7 6 3x6 4x6 3x6 6x6 5x12 3x12 3x6 3x6 3x6 5-11-0 5-11-0 12-4-0 6-5-0 18-3-0 5-11-0 5-11-0 5-11-0 9-3-9 3-4-9 12-4-0 3-0-7 18-3-0 5-11-0 1-7-012-5-21-11-122-8-1214.00 12 6.00 12 Plate Offsets (X,Y)-- [3:Edge,0-1-14], [7:0-6-4,0-2-12] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.70 0.30 0.70 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.05 -0.12 0.09 (loc) 7-8 7-8 6 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 97 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 1-9,5-6: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 2-7, 2-9, 4-6 REACTIONS. (size)9=0-5-8, 6=0-5-8 Max Horz 9=243(LC 9) Max Uplift 6=-3(LC 10) Max Grav 9=718(LC 1), 6=718(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-466/252, 2-3=-499/106, 3-4=-878/219, 4-5=-409/248, 1-9=-444/216, 5-6=-404/203 BOT CHORD 8-9=-124/760, 7-8=-98/652, 6-7=0/620 WEBS 2-8=0/455, 2-7=-454/170, 3-7=-227/854, 4-7=-308/353, 2-9=-651/0, 4-6=-757/21 NOTES-(8-9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) 0-1-12 to 3-1-12, Interior(1) 3-1-12 to 6-0-3, Exterior(2R) 6-0-3 to 12-2-13, Interior(1) 12-2-13 to 15-1-4, Exterior(2E) 15-1-4 to 18-1-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Bearing at joint(s) 9, 6 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 3 lb uplift at joint 6. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). June 25,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 2_HERITAGE_AT_SPRING~L Truss T19 Truss Type PIGGYBACK BASE Qty 2 Ply 1 2 Heritage at Spring Mill Job Reference (optional) I41794892 8.240 s Mar 9 2020 MiTek Industries, Inc. Wed Jun 24 18:32:42 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:EvWg2tiHQVSzJMSEDMv2ODzW2H3-6vR44W1lpAdBuUC686s47KpFnkf9EraWIXGTilz3_bZ Scale = 1:53.6 1 2 3 4 5 6 12 11 10 9 8 7 13 14 15 16 17 18 3x4 6x6 8x8 6x8 3x6 3x8 4x6 3x4 3x4 3x4 3x8 4x6 7-5-13 7-5-13 13-11-13 6-6-0 19-10-11 5-10-13 26-0-0 6-1-5 3-10-3 3-10-3 7-5-13 3-7-11 13-11-13 6-6-0 19-10-11 5-10-13 26-0-0 6-1-5 4-1-49-1-21-1-09-1-28.00 12 Plate Offsets (X,Y)-- [2:0-2-7,0-2-0], [3:0-3-0,0-2-3], [4:0-6-0,0-5-4], [6:0-3-8,Edge], [7:Edge,0-3-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.69 0.53 0.57 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.11 -0.18 0.03 (loc) 11-12 11-12 7 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 124 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 *Except* 3-4: 2x6 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 4-11: 2x4 SPF No.2, 1-12,6-7: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 4-8-8 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 3-4. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 4-11, 2-12 REACTIONS. (size)12=0-3-8, 7=0-5-8 Max Horz 12=-192(LC 6) Max Grav 12=1156(LC 2), 7=1126(LC 18) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-910/105, 3-4=-729/111, 4-5=-1119/92, 5-6=-1427/25, 6-7=-1015/22 BOT CHORD 11-12=-52/625, 9-11=0/873, 8-9=0/1117, 7-8=-46/346 WEBS 2-11=-24/356, 3-11=-8/254, 4-11=-299/57, 4-9=0/491, 5-9=-391/103, 2-12=-1004/0, 6-8=0/799 NOTES-(8-9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) 0-1-12 to 3-1-12, Exterior(2R) 3-1-12 to 18-2-12, Interior(1) 18-2-12 to 22-10-4, Exterior(2E) 22-10-4 to 25-10-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). June 25,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 2_HERITAGE_AT_SPRING~L Truss T20 Truss Type PIGGYBACK BASE Qty 2 Ply 1 2 Heritage at Spring Mill Job Reference (optional) I41794893 8.240 s Mar 9 2020 MiTek Industries, Inc. Wed Jun 24 18:32:43 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:EvWg2tiHQVSzJMSEDMv2ODzW2H3-b5?TIs2NaUl2VenIiqNJfYMQX7?OzIwfXA?0EBz3_bY Scale = 1:54.1 1 2 3 4 5 6 7 13 12 11 10 9 8 14 15 16 17 18 19 3x4 6x6 8x8 3x6 3x8 4x6 3x4 3x4 3x4 3x8 4x6 6x6 7-5-13 7-5-13 13-11-13 6-6-0 19-10-11 5-10-13 26-0-0 6-1-5 3-10-3 3-10-3 7-5-13 3-7-11 13-11-13 6-6-0 19-10-11 5-10-13 26-0-0 6-1-5 26-11-0 0-11-0 4-1-49-1-21-1-09-1-28.00 12 Plate Offsets (X,Y)-- [2:0-2-7,0-2-0], [3:0-3-0,0-2-3], [4:0-6-0,0-5-4], [8:Edge,0-3-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.69 0.53 0.56 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.11 -0.18 0.03 (loc) 12-13 12-13 8 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 125 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 *Except* 3-4: 2x6 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 4-12: 2x4 SPF No.2, 1-13,6-8: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 4-8-11 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 3-4. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 4-12, 2-13 REACTIONS. (size)13=0-3-8, 8=0-5-8 Max Horz 13=-200(LC 6) Max Uplift 8=-1(LC 11) Max Grav 13=1155(LC 2), 8=1185(LC 18) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-909/104, 3-4=-728/110, 4-5=-1117/90, 5-6=-1422/21, 6-8=-1074/39 BOT CHORD 12-13=-47/631, 10-12=0/871, 9-10=0/1112, 8-9=-33/315 WEBS 2-12=-24/356, 3-12=-8/254, 4-12=-298/57, 4-10=0/488, 5-10=-387/103, 2-13=-1002/0, 6-9=0/822 NOTES-(9-10) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) 0-1-12 to 3-1-12, Exterior(2R) 3-1-12 to 18-2-12, Interior(1) 18-2-12 to 23-11-0, Exterior(2E) 23-11-0 to 26-11-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 1 lb uplift at joint 8. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 9) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 10) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). June 25,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 2_HERITAGE_AT_SPRING~L Truss T21 Truss Type Piggyback Base Qty 1 Ply 1 2 Heritage at Spring Mill Job Reference (optional) I41794894 8.240 s Mar 9 2020 MiTek Industries, Inc. Wed Jun 24 18:32:44 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:EvWg2tiHQVSzJMSEDMv2ODzW2H3-3HYrVC3?Kotv7oMUGXuYCluctXM2ikMomqlandz3_bX Scale: 3/16"=1' 1 2 3 4 5 6 7 12 11 10 9 8 13 14 15 16 17 18 3x6 4x6 5x12 4x6 3x6 3x4 3x4 3x4 4x8 3x4 4x8 3x6 7-6-8 7-6-8 14-10-8 7-4-0 18-6-8 3-8-0 -1-3-8 1-3-8 5-1-3 5-1-3 9-11-13 4-10-11 14-10-8 4-10-11 18-6-8 3-8-0 1-1-011-0-09-1-1211-0-08.00 12 Plate Offsets (X,Y)-- [6:0-3-12,0-2-0], [7:0-5-8,0-3-0], [8:Edge,0-3-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.52 0.50 0.61 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.12 -0.19 -0.11 (loc) 9-10 9-10 14 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 108 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 7-8,6-9,7-9: 2x4 SPF No.2, 2-12: 2x4 SPF-S Stud OTHERS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 6-7. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 5-9, 6-9 REACTIONS. (size)12=0-3-8, 14=0-3-8 Max Horz 12=283(LC 7) Max Uplift 14=-57(LC 10) Max Grav 12=906(LC 17), 14=814(LC 17) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-4=-402/56, 4-5=-853/30, 5-6=-384/80, 6-7=-250/94, 2-12=-409/76 BOT CHORD 10-12=-104/828, 9-10=-79/586 WEBS 5-10=-10/480, 5-9=-552/132, 7-9=-71/850, 4-12=-628/0, 7-14=-820/63 NOTES-(9-10) 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -1-3-8 to 1-8-8, Interior(1) 1-8-8 to 10-7-9, Exterior(2R) 10-7-9 to 14-10-8, Exterior(2E) 14-10-8 to 18-1-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Provide adequate drainage to prevent water ponding. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 5) Bearing at joint(s) 14 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 57 lb uplift at joint 14. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 9) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 10) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). June 25,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 2_HERITAGE_AT_SPRING~L Truss T22 Truss Type Hip Qty 1 Ply 1 2 Heritage at Spring Mill Job Reference (optional) I41794895 8.240 s Mar 9 2020 MiTek Industries, Inc. Wed Jun 24 18:32:45 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:EvWg2tiHQVSzJMSEDMv2ODzW2H3-XU6DjX4d55?llxxgpFPnkzRnPxa_R6by_UU7J3z3_bW Scale = 1:85.1 1 2 3 4 5 6 7 8 9 10 18 17 16 15 14 13 12 11 19 20 21 22 23 24 25 26 27 5x10 MT18HS 3x6 3x4 3x6 3x8 3x4 3x4 3x6 4x6 12x12 5x10 MT18HS 3x4 3x4 12x18 MT18HS 8x14 MT18HS 11-3-0 11-3-0 18-0-11 6-9-11 28-4-12 10-4-1 31-8-0 3-3-4 42-11-0 11-3-0 -0-11-0 0-11-0 5-8-12 5-8-12 11-3-0 5-6-4 18-0-11 6-9-11 24-10-5 6-9-11 31-8-0 6-9-11 37-2-4 5-6-4 42-11-0 5-8-12 1-1-08-4-118-7-01-1-08-4-118.00 12 Plate Offsets (X,Y)-- [2:Edge,0-3-4], [2:0-1-12,0-1-3], [4:0-6-8,0-1-12], [8:0-6-0,0-1-8], [11:Edge,0-3-8], [13:0-0-0,0-1-12], [14:0-1-12,Edge], [15:0-2-8,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.53 0.97 0.93 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.43 -0.70 0.03 (loc) 14-15 14-15 11 l/defl >785 >484 n/a L/d 240 180 n/a PLATES MT20 MT18HS Weight: 185 lb FT = 20% GRIP 197/144 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 5-17,7-15: 2x4 SPF No.2, 2-18,10-11: 2x4 SPF 2100F 1.8E BRACING- TOP CHORD Structural wood sheathing directly applied or 5-3-4 oc purlins, except end verticals, and 2-0-0 oc purlins (5-7-14 max.): 4-8. BOT CHORD Structural wood sheathing directly applied or 2-2-0 oc bracing. WEBS 1 Row at midpt 7-14, 8-14 REACTIONS. (size)14=0-3-8, 18=0-3-8, 11=0-3-8 Max Horz 18=162(LC 7) Max Uplift 11=-28(LC 11) Max Grav 14=2220(LC 2), 18=1194(LC 25), 11=477(LC 18) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-827/0, 3-4=-1213/35, 4-5=-955/63, 5-7=-885/44, 7-8=-33/359, 9-10=-763/0, 2-18=-634/29, 10-11=-531/20 BOT CHORD 17-18=-77/1115, 15-17=-48/885 WEBS 4-17=0/344, 5-15=-533/106, 7-15=-4/1076, 7-14=-1275/133, 8-14=-791/23, 8-12=-0/427, 9-12=-350/132, 3-18=-723/87, 9-11=0/542 NOTES-(10-11) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -0-11-0 to 2-1-0, Interior(1) 2-1-0 to 7-0-1, Exterior(2R) 7-0-1 to 15-5-15, Interior(1) 15-5-15 to 27-5-1, Exterior(2R) 27-5-1 to 35-10-15, Interior(1) 35-10-15 to 39-9-4, Exterior(2E) 39-9-4 to 42-9-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 28 lb uplift at joint 11. 8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 10) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 11) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). June 25,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 2_HERITAGE_AT_SPRING~L Truss T23 Truss Type Hip Qty 1 Ply 1 2 Heritage at Spring Mill Job Reference (optional) I41794896 8.240 s Mar 9 2020 MiTek Industries, Inc. Wed Jun 24 18:32:46 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:EvWg2tiHQVSzJMSEDMv2ODzW2H3-?ggbwt4FsP7cM5WtNyx0HA_tQL1kAcv5D8EgrWz3_bV Scale = 1:82.4 1 2 3 4 5 6 7 8 9 10 11 12 21 20 19 18 17 16 15 14 13 22 23 24 25 26 27 28 29 3x6 5x10 MT18HS 5x6 3x6 5x6 3x6 3x4 3x4 3x8 3x4 4x6 4x6 4x8 3x4 3x4 3x4 6x8 3x8 3x4 3x6 7-5-12 7-5-12 14-9-0 7-3-4 19-2-11 4-5-11 28-2-0 8-11-5 28-6-8 0-4-8 35-5-4 6-10-12 42-11-0 7-5-12 -0-11-0 0-11-0 7-5-12 7-5-12 14-9-0 7-3-4 19-2-11 4-5-11 23-8-5 4-5-11 28-2-0 4-5-11 33-0-3 4-10-3 37-10-5 4-10-3 42-11-0 5-0-11 1-1-010-8-1110-11-01-1-010-8-118.00 12 Plate Offsets (X,Y)-- [2:0-3-8,Edge], [5:0-6-8,0-1-12] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.84 0.55 0.74 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.20 -0.32 0.02 (loc) 16-17 16-17 16 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 MT18HS Weight: 219 lb FT = 20% GRIP 169/123 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 *Except* 15-18: 2x4 SPF 2100F 1.8E WEBS 2x3 SPF No.2 *Except* 5-19,6-19,6-17,7-17,7-16,8-16: 2x4 SPF No.2 2-21,12-13: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 4-7-5 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 5-8. BOT CHORD Structural wood sheathing directly applied or 6-0-0 oc bracing. WEBS 1 Row at midpt 4-19, 6-17, 7-16, 8-16, 9-16 REACTIONS. (size)21=0-3-8, 16=0-3-8, 13=0-3-8 Max Horz 21=204(LC 7) Max Uplift 21=-14(LC 10), 13=-27(LC 11) Max Grav 21=1174(LC 17), 16=2395(LC 2), 13=395(LC 18) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-4=-1416/30, 4-5=-941/87, 5-6=-700/113, 6-7=-547/105, 7-8=0/392, 8-9=0/512, 10-12=-406/55, 2-21=-1049/56, 12-13=-323/57 BOT CHORD 20-21=-175/573, 19-20=-77/1185, 17-19=-80/573 WEBS 4-20=0/291, 4-19=-593/124, 6-19=-71/477, 6-17=-593/59, 7-17=0/972, 7-16=-1225/55, 8-16=-494/13, 9-16=-573/129, 9-14=-16/509, 10-14=-260/116, 2-20=0/699 NOTES-(10-11) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -0-11-0 to 2-1-0, Interior(1) 2-1-0 to 10-6-1, Exterior(2R) 10-6-1 to 19-2-11, Interior(1) 19-2-11 to 23-8-5, Exterior(2R) 23-8-5 to 32-4-15, Interior(1) 32-4-15 to 39-9-4, Exterior(2E) 39-9-4 to 42-9-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 14 lb uplift at joint 21 and 27 lb uplift at joint 13. 8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 10) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 11) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). June 25,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 2_HERITAGE_AT_SPRING~L Truss T24 Truss Type Piggyback Base Qty 2 Ply 1 2 Heritage at Spring Mill Job Reference (optional) I41794897 8.240 s Mar 9 2020 MiTek Industries, Inc. Wed Jun 24 18:32:48 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:EvWg2tiHQVSzJMSEDMv2ODzW2H3-x3oLLZ6WO0NKcPfFVNzUMb3FH8dyeX_OgSjnwOz3_bT Scale = 1:82.0 1 2 3 4 5 6 7 8 9 10 11 12 21 20 19 18 17 16 15 14 13 22 23 24 25 26 27 28 29 30 31 3x6 5x6 5x6 3x6 3x6 3x4 3x6 3x4 3x8 3x4 6x16 3x4 3x4 5x8 3x4 12x18 MT18HS 4x8 3x6 8-3-8 8-3-8 16-4-8 8-1-0 26-6-8 10-2-0 28-4-12 1-10-4 35-6-10 7-1-14 42-11-0 7-4-6 -0-11-0 0-11-0 5-7-3 5-7-3 10-11-13 5-4-11 16-4-8 5-4-11 21-5-8 5-1-0 26-6-8 5-1-0 31-11-3 5-4-11 37-3-13 5-4-11 42-11-0 5-7-3 1-1-012-0-01-1-012-0-08.00 12 Plate Offsets (X,Y)-- [2:Edge,0-3-4], [2:0-1-12,0-1-3], [4:0-2-8,0-1-8], [6:0-4-4,0-2-4], [8:0-4-4,0-2-4], [16:0-0-0,0-1-12], [17:0-4-0,0-3-4], [17:0-1-12,0-0-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.75 0.89 0.70 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.36 -0.59 0.05 (loc) 17-18 17-18 13 l/defl >936 >577 n/a L/d 240 180 n/a PLATES MT20 MT18HS Weight: 220 lb FT = 20% GRIP 169/123 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 6-18,7-18,7-17,8-17,9-15: 2x4 SPF No.2, 2-21,12-13: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 4-6-1 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 6-8. BOT CHORD Structural wood sheathing directly applied or 2-2-0 oc bracing. WEBS 1 Row at midpt 5-18, 7-17, 8-17, 9-15, 4-21 REACTIONS. (size)15=0-3-8, 21=0-3-8, 13=0-3-8 Max Horz 21=225(LC 7) Max Uplift 21=-4(LC 10), 13=-4(LC 11) Max Grav 15=1857(LC 2), 21=1363(LC 17), 13=726(LC 18) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-4=-602/61, 4-5=-1561/64, 5-6=-1089/98, 6-7=-846/114, 7-8=-305/129, 8-9=-445/115, 9-10=-727/97, 10-12=-484/82, 2-21=-513/77, 12-13=-383/76 BOT CHORD 20-21=-78/1423, 18-20=-53/1204, 17-18=-54/674, 15-17=-474/79, 14-15=0/325, 13-14=0/594 WEBS 5-20=-20/448, 5-18=-564/146, 6-18=0/324, 7-18=-33/651, 7-17=-844/66, 9-17=0/1355, 9-15=-1878/0, 9-14=-39/548, 4-21=-1157/0, 10-13=-383/0 NOTES-(10-11) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -0-11-0 to 2-1-0, Interior(1) 2-1-0 to 12-1-9, Exterior(2R) 12-1-9 to 20-7-7, Interior(1) 20-7-7 to 22-3-9, Exterior(2R) 22-3-9 to 30-9-7, Interior(1) 30-9-7 to 39-9-4, Exterior(2E) 39-9-4 to 42-9-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 4 lb uplift at joint 21 and 4 lb uplift at joint 13. 8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 10) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 11) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). June 25,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 2_HERITAGE_AT_SPRING~L Truss T25 Truss Type Half Hip Qty 2 Ply 1 2 Heritage at Spring Mill Job Reference (optional) I41794898 8.240 s Mar 9 2020 MiTek Industries, Inc. Wed Jun 24 18:32:48 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:EvWg2tiHQVSzJMSEDMv2ODzW2H3-x3oLLZ6WO0NKcPfFVNzUMb3P88pmehTOgSjnwOz3_bT Scale = 1:21.8 1 2 3 4 7 6 5 4x8 3x4 3x4 3x4 2x4 3x4 1-10-5 1-10-5 4-0-0 2-1-11 -0-11-0 0-11-0 1-10-5 1-10-5 4-0-0 2-1-11 1-7-03-7-33-9-03-7-314.00 12 Plate Offsets (X,Y)-- [3:0-5-3,0-2-0], [4:Edge,0-2-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.12 0.07 0.03 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 -0.00 -0.00 (loc) 6 6 5 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 21 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 2-7: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 4-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins: 3-4. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS. (size)5=Mechanical, 7=0-3-8 Max Horz 7=103(LC 7) Max Uplift 5=-45(LC 7) Max Grav 5=141(LC 1), 7=223(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(10-11) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Refer to girder(s) for truss to truss connections. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 45 lb uplift at joint 5. 8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 10) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 11) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). June 25,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 2_HERITAGE_AT_SPRING~L Truss T26 Truss Type Half Hip Qty 1 Ply 1 2 Heritage at Spring Mill Job Reference (optional) I41794899 8.240 s Mar 9 2020 MiTek Industries, Inc. Wed Jun 24 18:32:49 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:EvWg2tiHQVSzJMSEDMv2ODzW2H3-PFMkYv789KVBEZES25UjvpcZ9Y9dN7WYv6SLSrz3_bS Scale = 1:28.6 1 2 3 4 7 6 5 4x8 3x4 3x4 3x4 2x4 3x4 3-0-0 3-0-0 4-0-0 1-0-0 -0-11-0 0-11-0 3-0-0 3-0-0 4-0-0 1-0-0 1-7-04-11-35-1-04-11-314.00 12 Plate Offsets (X,Y)-- [3:0-5-3,0-2-0], [4:Edge,0-2-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.16 0.09 0.11 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 -0.01 -0.00 (loc) 6-7 6-7 5 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 25 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 2-7: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 4-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins: 3-4. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS. (size)5=Mechanical, 7=0-3-8 Max Horz 7=139(LC 7) Max Uplift 5=-75(LC 7) Max Grav 5=161(LC 17), 7=230(LC 18) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(10-11) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -0-11-0 to 2-1-0, Exterior(2R) 2-1-0 to 3-0-0, Exterior(2E) 3-0-0 to 3-10-12 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Refer to girder(s) for truss to truss connections. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 75 lb uplift at joint 5. 8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 10) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 11) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). June 25,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 2_HERITAGE_AT_SPRING~L Truss T27 Truss Type Half Hip Qty 1 Ply 1 2 Heritage at Spring Mill Job Reference (optional) I41794900 8.240 s Mar 9 2020 MiTek Industries, Inc. Wed Jun 24 18:32:50 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:EvWg2tiHQVSzJMSEDMv2ODzW2H3-tRw6mF8mwed2rjpeco?yR08j4yVZ6Zlh8mCu_Hz3_bR Scale = 1:31.3 1 2 3 4 7 6 5 5x6 3x4 3x6 3x4 2x4 3x4 2-0-0 2-0-0 4-0-0 2-0-0 -0-11-0 0-11-0 3-5-7 3-5-7 4-0-0 0-6-9 1-7-05-5-85-7-55-5-814.00 12 Plate Offsets (X,Y)-- [3:0-3-10,0-2-8], [4:Edge,0-2-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.22 0.11 0.17 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.01 -0.01 -0.00 (loc) 5-6 5-6 5 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 27 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 2-7: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 4-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins: 3-4. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS. (size)5=Mechanical, 7=0-3-8 Max Horz 7=154(LC 7) Max Uplift 5=-89(LC 7), 7=-7(LC 6) Max Grav 5=179(LC 17), 7=245(LC 18) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 3-5=-263/211 NOTES-(10-11) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -0-11-0 to 2-1-0, Exterior(2R) 2-1-0 to 3-5-7, Exterior(2E) 3-5-7 to 3-10-12 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Refer to girder(s) for truss to truss connections. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 89 lb uplift at joint 5 and 7 lb uplift at joint 7. 8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 10) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 11) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). June 25,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 2_HERITAGE_AT_SPRING~L Truss T28 Truss Type Half Hip Qty 1 Ply 1 2 Heritage at Spring Mill Job Reference (optional) I41794901 8.240 s Mar 9 2020 MiTek Industries, Inc. Wed Jun 24 18:32:50 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:EvWg2tiHQVSzJMSEDMv2ODzW2H3-tRw6mF8mwed2rjpeco?yR08kSyWG6bhh8mCu_Hz3_bR Scale = 1:24.5 1 2 3 4 7 6 5 4x8 3x4 3x4 3x4 2x4 3x4 2-3-11 2-3-11 4-0-0 1-8-5 -0-11-0 0-11-0 2-3-11 2-3-11 4-0-0 1-8-5 1-7-04-1-84-3-54-1-814.00 12 Plate Offsets (X,Y)-- [3:0-5-3,0-2-0], [4:Edge,0-2-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.13 0.06 0.05 DEFL. Vert(LL) Vert(CT) Horz(CT) in 0.00 -0.00 -0.00 (loc) 6 6 5 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 23 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 2-7: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 4-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins: 3-4. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS. (size)5=Mechanical, 7=0-3-8 Max Horz 7=117(LC 7) Max Uplift 5=-55(LC 7) Max Grav 5=141(LC 1), 7=223(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(10-11) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Refer to girder(s) for truss to truss connections. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 55 lb uplift at joint 5. 8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 10) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 11) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). June 25,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 2_HERITAGE_AT_SPRING~L Truss T29 Truss Type Roof Special Qty 1 Ply 1 2 Heritage at Spring Mill Job Reference (optional) I41794902 8.240 s Mar 9 2020 MiTek Industries, Inc. Wed Jun 24 18:32:52 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:EvWg2tiHQVSzJMSEDMv2ODzW2H3-qq1sBx90SFum50z1kD2QXREvYm1QaNq_b4h?39z3_bP Scale = 1:54.9 1 2 3 4 5 6 7 13 12 11 10 9 8 14 15 16 17 18 19 20 21 5x8 5x10 MT18HS 5x6 5x6 3x4 3x6 3x8 3x4 4x8 3x4 6x8 4x6 3x4 6-8-10 6-8-10 14-9-0 8-0-6 23-2-8 8-5-8 25-10-8 2-8-0 6-8-10 6-8-10 10-8-13 4-0-3 14-9-0 4-0-3 18-11-12 4-2-12 23-2-8 4-2-12 25-9-8 2-7-0 25-10-8 0-1-0 4-1-48-4-112-9-08-7-02-9-08-4-118.00 12 Plate Offsets (X,Y)-- [1:Edge,0-1-14], [2:0-6-8,0-1-12], [6:0-3-0,0-3-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.86 0.72 0.52 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.14 -0.25 0.03 (loc) 10-12 9-10 8 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 MT18HS Weight: 125 lb FT = 20% GRIP 169/123 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 *Except* 4-6,6-7: 2x6 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 6-9,1-13,7-8: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 5-6-7 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 2-4, 6-7. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 3-12, 3-10 REACTIONS. (size)13=0-3-8, 8=Mechanical Max Horz 13=-181(LC 6) Max Grav 13=1132(LC 2), 8=1136(LC 2) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-952/84, 2-3=-723/107, 3-4=-933/99, 4-5=-1169/90, 5-6=-1362/60, 6-7=-1153/12, 1-13=-1034/39, 7-8=-1142/0 BOT CHORD 10-12=-8/873, 9-10=0/1058 WEBS 2-12=0/266, 3-12=-390/85, 4-10=0/398, 5-10=-269/112, 6-9=-812/63, 7-9=0/1507, 1-12=0/780 NOTES-(10-11) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) 0-1-12 to 3-1-12, Interior(1) 3-1-12 to 3-8-10, Exterior(2R) 3-8-10 to 9-8-10, Interior(1) 9-8-10 to 11-9-0, Exterior(2R) 11-9-0 to 17-9-0, Interior(1) 17-9-0 to 23-2-8, Exterior(2E) 23-2-8 to 25-8-12 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 7) Refer to girder(s) for truss to truss connections. 8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 10) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 11) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). June 25,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 2_HERITAGE_AT_SPRING~L Truss T30 Truss Type Half Hip Qty 1 Ply 1 2 Heritage at Spring Mill Job Reference (optional) I41794903 8.240 s Mar 9 2020 MiTek Industries, Inc. Wed Jun 24 18:32:52 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:EvWg2tiHQVSzJMSEDMv2ODzW2H3-qq1sBx90SFum50z1kD2QXRE2nmBoaUi_b4h?39z3_bP Scale = 1:30.3 1 2 3 4 7 6 5 4x10 3x4 3x4 2x4 3x4 3-3-8 3-3-8 4-0-0 0-8-8 -0-11-0 0-11-0 3-3-8 3-3-8 4-0-0 0-8-8 1-7-05-5-114.00 12 Plate Offsets (X,Y)-- [3:Edge,0-1-12], [4:0-1-4,0-0-0], [5:Edge,0-2-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.27 0.12 0.08 DEFL. Vert(LL) Vert(CT) Horz(CT) in 0.02 -0.02 -0.00 (loc) 6-7 6-7 5 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 22 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 2-7: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 4-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins: 3-4. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS. (size)5=Mechanical, 7=0-5-8 Max Horz 7=153(LC 7) Max Uplift 5=-90(LC 7), 7=-5(LC 6) Max Grav 5=174(LC 17), 7=244(LC 18) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(9-10) 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -0-11-0 to 2-1-0, Exterior(2R) 2-1-0 to 3-3-8, Exterior(2E) 3-3-8 to 3-10-12 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Provide adequate drainage to prevent water ponding. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 90 lb uplift at joint 5 and 5 lb uplift at joint 7. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 9) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 10) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). June 25,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 2_HERITAGE_AT_SPRING~L Truss T31 Truss Type Common Qty 2 Ply 1 2 Heritage at Spring Mill Job Reference (optional) I41794904 8.240 s Mar 9 2020 MiTek Industries, Inc. Wed Jun 24 18:32:53 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:EvWg2tiHQVSzJMSEDMv2ODzW2H3-I0bEOHAeDZ0diAYDHwZf3fmD09WkJx?7qkQYbcz3_bO Scale = 1:32.5 1 2 3 6 5 4 5x8 3x4 3x4 2x4 3x4 2-0-0 2-0-0 4-0-0 2-0-0 -0-11-0 0-11-0 3-7-12 3-7-12 4-0-0 0-4-4 1-7-05-10-15-5-114.00 12 *** Design Problems *** REVIEW REQUIRED Analog warning - check designPlate Offsets (X,Y)-- [3:Edge,0-2-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.30 0.14 0.07 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.01 -0.01 -0.00 (loc) 4-5 4-5 4 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 24 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud *Except* 3-5: 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 4-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS. (size)6=0-5-8, 4=Mechanical Max Horz 6=168(LC 7) Max Uplift 6=-22(LC 6), 4=-107(LC 7) Max Grav 6=261(LC 18), 4=198(LC 17) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(7-8) 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 22 lb uplift at joint 6 and 107 lb uplift at joint 4. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). June 25,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 2_HERITAGE_AT_SPRING~L Truss T32 Truss Type Roof Special Qty 1 Ply 1 2 Heritage at Spring Mill Job Reference (optional) I41794905 8.240 s Mar 9 2020 MiTek Industries, Inc. Wed Jun 24 18:32:53 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:EvWg2tiHQVSzJMSEDMv2ODzW2H3-I0bEOHAeDZ0diAYDHwZf3fm579S1JnF7qkQYbcz3_bO Scale = 1:50.5 1 2 3 6 5 4 7 6x8 3x6 5x6 4x6 3x4 8x14 MT18HS 9-2-6 9-2-6 11-10-0 2-7-10 9-2-6 9-2-6 11-10-0 2-7-10 4-11-07-2-108-11-113.00 12 8.00 12 Plate Offsets (X,Y)-- [1:0-3-0,0-2-4], [2:0-3-12,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.81 0.44 0.76 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.14 -0.27 -0.00 (loc) 5-6 5-6 4 l/defl >999 >522 n/a L/d 240 180 n/a PLATES MT20 MT18HS Weight: 59 lb FT = 20% GRIP 197/144 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 1-6: 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS. (size)4=Mechanical, 6=0-3-8 Max Horz 6=234(LC 7) Max Uplift 4=-49(LC 7), 6=-43(LC 6) Max Grav 4=463(LC 1), 6=463(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-288/74, 1-6=-367/116 WEBS 2-5=-3/286, 2-4=-578/202 NOTES-(8-9) 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) 0-1-12 to 3-1-12, Interior(1) 3-1-12 to 9-2-6, Exterior(2E) 9-2-6 to 11-8-12 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) All plates are MT20 plates unless otherwise indicated. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 49 lb uplift at joint 4 and 43 lb uplift at joint 6. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). June 25,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 2_HERITAGE_AT_SPRING~L Truss T33 Truss Type Half Hip Qty 1 Ply 1 2 Heritage at Spring Mill Job Reference (optional) I41794906 8.240 s Mar 9 2020 MiTek Industries, Inc. Wed Jun 24 18:32:54 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:EvWg2tiHQVSzJMSEDMv2ODzW2H3-mD9dbcBG_s8UKK7Pre4ucsJOZZuX2PbH3OA672z3_bN Scale = 1:28.9 1 2 3 6 5 4 4x6 3x4 3x4 3x8 5x8 6x6 2-7-0 2-7-0 3-6-8 0-11-8 2-7-0 2-7-0 3-6-8 0-11-8 2-1-75-1-91-8-10-3-84-10-15-1-914.00 12 Plate Offsets (X,Y)-- [1:Edge,0-1-5], [2:0-4-8,0-1-12], [4:Edge,0-2-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.31 0.04 0.05 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 -0.00 -0.00 (loc) 5-6 5-6 3 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 25 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 1-6: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 3-6-8 oc purlins, except end verticals, and 2-0-0 oc purlins: 2-3. BOT CHORD Structural wood sheathing directly applied or 6-0-0 oc bracing. REACTIONS. (size)4=Mechanical, 6=Mechanical, 1=Mechanical, 3=Mechanical Max Horz 6=52(LC 9), 1=94(LC 7) Max Uplift 4=-12(LC 3), 1=-5(LC 10), 3=-31(LC 7) Max Grav 6=43(LC 3), 1=128(LC 18), 3=118(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(11-12) 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Provide adequate drainage to prevent water ponding. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 12 lb uplift at joint 4, 5 lb uplift at joint 1 and 31 lb uplift at joint 3. 7) Non Standard bearing condition. Review required. 8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 10) Gap between inside of top chord bearing and first diagonal or vertical web shall not exceed 0.500in. 11) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 12) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). June 25,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 2_HERITAGE_AT_SPRING~L Truss T34 Truss Type Hip Qty 1 Ply 1 2 Heritage at Spring Mill Job Reference (optional) I41794907 8.240 s Mar 9 2020 MiTek Industries, Inc. Wed Jun 24 18:32:55 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:ErDeBhooCW6W7KTmKQR8snz73g9-EPj?pyBvlAGLyUibPLb784rUEz2snfpQI2vfgUz3_bM Scale = 1:70.6 1 2 3 4 5 6 7 8 910 15 14 13 12 111617181920 3x6 4x6 6x6 3x6 3x6 3x8 3x4 3x4 3x4 3x6 5x10 MT18HS 5x10 MT18HS 3x6 9-3-11 9-3-11 13-11-5 4-7-9 23-3-0 9-3-11 -1-0-0 1-0-0 4-9-2 4-9-2 9-3-11 4-6-10 13-11-5 4-7-9 18-5-14 4-6-10 23-3-0 4-9-2 24-3-0 1-0-0 1-7-012-5-51-7-012-5-514.00 12 Plate Offsets (X,Y)-- [5:0-3-2,0-2-0], [6:0-3-0,0-1-8], [11:Edge,0-1-8], [15:Edge,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.64 0.74 0.89 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.25 -0.41 0.02 (loc) 11-12 11-12 11 l/defl >999 >677 n/a L/d 240 180 n/a PLATES MT20 MT18HS Weight: 138 lb FT = 20% GRIP 197/144 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 *Except* 4-13,7-12,4-15,7-11: 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 5-6. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 4-13, 6-13, 7-12 REACTIONS. (size)15=0-3-8, 11=0-3-8 Max Horz 15=-262(LC 8) Max Grav 15=1109(LC 2), 11=1112(LC 2) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-4=-608/105, 4-5=-856/147, 5-6=-504/142, 6-7=-859/147, 7-9=-609/105, 2-15=-593/104, 9-11=-594/104 BOT CHORD 13-15=-98/682, 12-13=-0/556, 11-12=0/580 WEBS 5-13=-60/392, 6-12=-78/426, 4-15=-566/58, 7-11=-565/59 NOTES-(9-10) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 5-0-13, Exterior(2R) 5-0-13 to 18-2-3, Interior(1) 18-2-3 to 21-3-0, Exterior(2E) 21-3-0 to 24-3-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 9) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 10) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). June 25,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 2_HERITAGE_AT_SPRING~L Truss T35 Truss Type Piggyback Base Qty 1 Ply 1 2 Heritage at Spring Mill Job Reference (optional) I41794908 8.240 s Mar 9 2020 MiTek Industries, Inc. Wed Jun 24 18:32:56 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:EvWg2tiHQVSzJMSEDMv2ODzW2H3-ibHN0ICXWUOCZeHoz36MhHOfyNP3W6ZaWifCCxz3_bL Scale = 1:68.1 1 2 3 4 5 6 7 8 13 12 11 10 91415161718 4x6 6x6 3x6 3x8 3x4 3x4 3x4 3x4 5x10 MT18HS 5x10 MT18HS 3x4 8-11-2 8-11-2 14-3-14 5-4-11 23-3-0 8-11-2 -1-0-0 1-0-0 4-6-13 4-6-13 8-11-2 4-4-5 14-3-14 5-4-11 18-8-3 4-4-5 23-3-0 4-6-13 24-3-0 1-0-0 1-7-012-0-01-7-012-0-014.00 12 Plate Offsets (X,Y)-- [4:0-3-2,0-2-0], [5:0-3-0,0-1-8], [9:Edge,0-1-12], [13:Edge,0-1-12] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.58 0.68 0.85 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.21 -0.34 0.02 (loc) 9-10 9-10 9 l/defl >999 >814 n/a L/d 240 180 n/a PLATES MT20 MT18HS Weight: 136 lb FT = 20% GRIP 197/144 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 *Except* 3-11,6-10,3-13,6-9: 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 4-5. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 5-11 REACTIONS. (size)13=0-3-8, 9=0-3-8 Max Horz 13=254(LC 9) Max Grav 13=1107(LC 2), 9=1111(LC 2) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-566/104, 3-4=-864/141, 4-5=-515/137, 5-6=-869/141, 6-7=-566/105, 2-13=-559/100, 7-9=-559/100 BOT CHORD 11-13=-99/675, 10-11=-0/559, 9-10=0/574 WEBS 4-11=-49/381, 5-10=-71/421, 3-13=-588/47, 6-9=-587/48 NOTES-(9-10) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 4-5-12, Exterior(2R) 4-5-12 to 18-9-4, Interior(1) 18-9-4 to 21-3-0, Exterior(2E) 21-3-0 to 24-3-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 9) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 10) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). June 25,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 2_HERITAGE_AT_SPRING~L Truss T36 Truss Type Piggyback Base Qty 1 Ply 1 2 Heritage at Spring Mill Job Reference (optional) I41794909 8.240 s Mar 9 2020 MiTek Industries, Inc. Wed Jun 24 18:32:57 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:EvWg2tiHQVSzJMSEDMv2ODzW2H3-AorlEeD9HnW2Bnr_WmdbEVxqinlIFZojlMOmkNz3_bK Scale = 1:68.1 1 2 3 4 5 6 7 8 13 12 11 10 91415161718 4x6 6x6 3x6 3x8 3x4 3x4 3x4 3x4 5x10 MT18HS 5x10 MT18HS 3x4 8-11-2 8-11-2 14-3-14 5-4-11 23-3-0 8-11-2 -1-0-0 1-0-0 4-6-13 4-6-13 8-11-2 4-4-5 14-3-14 5-4-11 18-8-3 4-4-5 23-3-0 4-6-13 24-3-0 1-0-0 1-7-012-0-01-7-012-0-014.00 12 Plate Offsets (X,Y)-- [4:0-3-2,0-2-0], [5:0-3-0,0-1-8], [9:Edge,0-1-12], [13:Edge,0-1-12] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.58 0.68 0.85 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.21 -0.34 0.02 (loc) 9-10 9-10 9 l/defl >999 >814 n/a L/d 240 180 n/a PLATES MT20 MT18HS Weight: 136 lb FT = 20% GRIP 197/144 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 *Except* 3-11,6-10,3-13,6-9: 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 4-5. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 5-11 REACTIONS. (size)13=0-3-8, 9=0-3-8 Max Horz 13=-254(LC 8) Max Grav 13=1107(LC 2), 9=1111(LC 2) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-566/104, 3-4=-864/141, 4-5=-515/137, 5-6=-869/141, 6-7=-566/105, 2-13=-559/100, 7-9=-559/100 BOT CHORD 11-13=-99/675, 10-11=-0/559, 9-10=0/574 WEBS 4-11=-49/381, 5-10=-71/421, 3-13=-588/47, 6-9=-587/48 NOTES-(9-10) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 4-5-12, Exterior(2R) 4-5-12 to 18-9-4, Interior(1) 18-9-4 to 21-3-0, Exterior(2E) 21-3-0 to 24-3-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 9) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 10) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). June 25,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 2_HERITAGE_AT_SPRING~L Truss T37 Truss Type Roof Special Qty 1 Ply 1 2 Heritage at Spring Mill Job Reference (optional) I41794910 8.240 s Mar 9 2020 MiTek Industries, Inc. Wed Jun 24 18:32:58 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:EvWg2tiHQVSzJMSEDMv2ODzW2H3-e_P7R_En15evpxQA4T8qmiT4_AAY_2xs_08JGpz3_bJ Scale = 1:58.1 1 2 3 4 5 6 10 9 8 7 11 12 3x4 4x6 6x10 6x10 3x8 3x8 3x6 3x4 3x6 3-3-4 3-3-4 9-7-12 6-4-7 12-11-0 3-3-4 3-3-4 3-3-4 6-5-8 3-2-4 9-7-12 3-2-4 12-11-0 3-3-4 13-11-0 1-0-0 1-7-09-1-71-7-02-2-1314.00 12 9.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.29 0.36 0.73 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.09 -0.16 0.09 (loc) 8-9 8-9 7 l/defl >999 >939 n/a L/d 240 180 n/a PLATES MT20 Weight: 69 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 1-10,5-7: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 5-11-9 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS. (size)10=0-3-8, 7=0-3-8 Max Horz 10=-192(LC 8) Max Uplift 10=-4(LC 11), 7=-1(LC 10) Max Grav 10=581(LC 18), 7=633(LC 17) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-270/116, 2-3=-968/173, 3-4=-831/107, 1-10=-264/95, 5-7=-286/122 BOT CHORD 9-10=-116/899, 8-9=-30/361, 7-8=0/770 WEBS 3-8=-104/583, 4-8=-109/257, 3-9=-166/743, 2-10=-874/0, 4-7=-958/0 NOTES-(8-9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) 0-1-12 to 3-4-7, Exterior(2R) 3-4-7 to 9-6-9, Interior(1) 9-6-9 to 10-11-0, Exterior(2E) 10-11-0 to 13-11-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 5) Bearing at joint(s) 10, 7 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 4 lb uplift at joint 10 and 1 lb uplift at joint 7. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). June 25,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 2_HERITAGE_AT_SPRING~L Truss T38 Truss Type Roof Special Qty 3 Ply 1 2 Heritage at Spring Mill Job Reference (optional) I41794911 8.240 s Mar 9 2020 MiTek Industries, Inc. Wed Jun 24 18:32:59 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:EvWg2tiHQVSzJMSEDMv2ODzW2H3-7AyWfKFPoPmmQ5?NeBg3Jw0ELaYzjS20CgtspGz3_bI Scale = 1:57.1 1 2 3 4 5 6 10 9 8 7 3x4 4x6 5x6 5x12 3x12 3x6 3x4 3x6 3x4 4-1-0 4-1-0 8-4-0 4-3-0 12-8-0 4-4-0 4-1-0 4-1-0 6-2-8 2-1-8 8-4-0 2-1-8 12-8-0 4-4-0 13-8-0 1-0-0 1-10-149-1-131-7-00-0-63-0-614.00 12 9.00 12 Plate Offsets (X,Y)-- [3:Edge,0-1-14] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.38 0.22 0.87 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.03 -0.07 0.09 (loc) 8-9 8-9 7 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 70 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 1-10,5-7: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS. (size)10=Mechanical, 7=0-3-8 Max Horz 10=-192(LC 6) Max Uplift 10=-4(LC 11) Max Grav 10=492(LC 1), 7=567(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-302/147, 2-3=-356/43, 3-4=-704/101, 4-5=-304/180, 1-10=-296/122, 5-7=-349/161 BOT CHORD 9-10=-113/693, 8-9=-79/530, 7-8=0/608 WEBS 2-9=-10/475, 2-8=-351/108, 3-8=-107/687, 4-8=-201/285, 2-10=-590/0, 4-7=-678/2 NOTES-(9-10) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) 0-1-12 to 3-1-12, Exterior(2R) 3-1-12 to 9-2-8, Interior(1) 9-2-8 to 10-8-0, Exterior(2E) 10-8-0 to 13-8-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Bearing at joint(s) 7 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 4 lb uplift at joint 10. 8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 10) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). June 25,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 2_HERITAGE_AT_SPRING~L Truss T39 Truss Type Half Hip Qty 1 Ply 1 2 Heritage at Spring Mill Job Reference (optional) I41794912 8.240 s Mar 9 2020 MiTek Industries, Inc. Wed Jun 24 18:32:59 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:EvWg2tiHQVSzJMSEDMv2ODzW2H3-7AyWfKFPoPmmQ5?NeBg3Jw0A0aYRjcn0CgtspGz3_bI Scale = 1:56.6 1 2 3 4 7 6 5 3x4 4x6 3x8 MT18HS 4x8 3x4 3x6 2x4 3-4-0 3-4-0 7-1-8 3-9-8 3-4-0 3-4-0 6-5-8 3-1-8 7-1-8 0-8-0 1-7-09-1-714.00 12 Plate Offsets (X,Y)-- [3:0-4-8,0-1-12], [4:0-3-8,Edge], [5:0-3-0,0-1-12] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.59 0.25 0.25 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.03 -0.04 -0.00 (loc) 5-6 5-6 5 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 MT18HS Weight: 44 lb FT = 20% GRIP 169/123 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 1-7: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 3-4. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 3-5 REACTIONS. (size)5=Mechanical, 7=0-3-8 Max Horz 7=239(LC 7) Max Uplift 5=-133(LC 7), 7=-8(LC 6) Max Grav 5=331(LC 17), 7=336(LC 18) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-306/67, 1-7=-272/59 WEBS 2-5=-259/148 NOTES-(10-11) 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) 0-1-12 to 3-3-15, Exterior(2R) 3-3-15 to 6-5-8, Exterior(2E) 6-5-8 to 7-0-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Provide adequate drainage to prevent water ponding. 3) All plates are MT20 plates unless otherwise indicated. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Refer to girder(s) for truss to truss connections. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 133 lb uplift at joint 5 and 8 lb uplift at joint 7. 8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 10) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 11) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). June 25,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 2_HERITAGE_AT_SPRING~L Truss T40 Truss Type Half Hip Qty 1 Ply 1 2 Heritage at Spring Mill Job Reference (optional) I41794913 8.240 s Mar 9 2020 MiTek Industries, Inc. Wed Jun 24 18:33:00 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:EvWg2tiHQVSzJMSEDMv2ODzW2H3-bMWusgF1Ziud2FaZCuBIr7ZPx_wlS6w9RKdQLiz3_bH Scale = 1:29.6 1 2 3 4 7 6 5 4x6 3x4 3x4 3x4 2x4 3x4 3-2-1 3-2-1 4-0-0 0-9-15 -0-11-0 0-11-0 3-2-1 3-2-1 4-0-0 0-9-15 1-7-05-3-714.00 12 Plate Offsets (X,Y)-- [3:0-4-8,0-1-12], [4:Edge,0-2-8], [5:Edge,0-2-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.26 0.12 0.06 DEFL. Vert(LL) Vert(CT) Horz(CT) in 0.02 -0.02 -0.00 (loc) 6-7 6-7 5 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 22 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 2-7: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 4-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins: 3-4. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS. (size)5=Mechanical, 7=0-3-8 Max Horz 7=149(LC 9) Max Uplift 5=-86(LC 7), 7=-3(LC 6) Max Grav 5=169(LC 17), 7=240(LC 18) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(9-10) 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -0-11-0 to 2-1-0, Exterior(2R) 2-1-0 to 3-2-1, Exterior(2E) 3-2-1 to 3-10-12 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Provide adequate drainage to prevent water ponding. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 86 lb uplift at joint 5 and 3 lb uplift at joint 7. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 9) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 10) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). June 25,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 2_HERITAGE_AT_SPRING~L Truss TG01 Truss Type Half Hip Girder Qty 1 Ply 1 2 Heritage at Spring Mill Job Reference (optional) I41794914 8.240 s Mar 9 2020 MiTek Industries, Inc. Wed Jun 24 18:33:01 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:EvWg2tiHQVSzJMSEDMv2ODzW2H3-3Z4G40GfK00UgP9llciXOL5c5OGIBYlJg_Mzt8z3_bG Scale = 1:15.3 1 2 3 4 7 6 5 5x6 3x4 3x4 3x4 3x4 4x6 2-0-0 2-0-0 4-0-0 2-0-0 -0-11-0 0-11-0 0-9-5 0-9-5 4-0-0 3-2-11 1-7-02-4-02-5-132-4-014.00 12 Plate Offsets (X,Y)-- [3:0-3-10,0-2-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.17 0.03 0.09 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 -0.00 -0.00 (loc) 6 6 5 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 23 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x6 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 4-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins: 3-4. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS. (size)5=Mechanical, 7=0-3-8 Max Horz 7=66(LC 7) Max Uplift 5=-54(LC 5), 7=-32(LC 8) Max Grav 5=245(LC 22), 7=323(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(12-13) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Refer to girder(s) for truss to truss connections. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 54 lb uplift at joint 5 and 32 lb uplift at joint 7. 8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 10) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 203 lb down and 69 lb up at 2-0-12 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 11) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). 12) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 13) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-2=-60, 2-3=-60, 3-4=-60, 5-7=-20 Concentrated Loads (lb) Vert: 6=-203(B) June 25,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 2_HERITAGE_AT_SPRING~L Truss TG02 Truss Type Hip Girder Qty 1 Ply 1 2 Heritage at Spring Mill Job Reference (optional) I41794915 8.240 s Mar 9 2020 MiTek Industries, Inc. Wed Jun 24 18:33:03 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:EvWg2tiHQVSzJMSEDMv2ODzW2H3-?xC0UhIwsdGCvjJ8t1k?TlBp5BjFfLBb7Ir4y1z3_bE Scale = 1:34.1 1 2 3 4 5 6 7 8 14 13 12 11 10 9 15 16 17 18 19 20 21 22 23 24 25 26 27 5x12 5x12 4x6 3x4 6x10 6x10 3x4 3x4 2x4 3x12 2x4 3x4 4x6 1-10-5 1-10-5 4-1-8 2-3-3 14-1-8 10-0-0 16-8-13 2-7-5 18-3-0 1-6-3 -0-11-0 0-11-0 1-10-5 1-10-5 4-1-8 2-3-3 9-1-8 5-0-0 14-1-8 5-0-0 16-8-13 2-7-5 18-3-0 1-6-3 1-7-03-7-33-9-01-11-121-10-01-9-314.00 12 6.00 12 Plate Offsets (X,Y)-- [3:0-9-10,0-2-8], [5:0-2-4,0-1-8], [7:0-9-10,0-2-8], [11:0-5-8,0-3-12], [12:0-5-4,0-3-12] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.71 0.96 0.54 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.14 -0.35 0.21 (loc) 11-12 11-12 9 l/defl >999 >608 n/a L/d 240 180 n/a PLATES MT20 Weight: 88 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x6 SPF No.2 WEBS 2x4 SPF-S Stud *Except* 3-12,7-11: 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 5-9-1 oc purlins, except end verticals, and 2-0-0 oc purlins (2-11-8 max.): 3-7. BOT CHORD Structural wood sheathing directly applied or 6-0-0 oc bracing. REACTIONS. (size)14=0-5-8, 9=0-5-8 Max Horz 14=92(LC 5) Max Uplift 14=-182(LC 5), 9=-202(LC 5) Max Grav 14=1084(LC 1), 9=1013(LC 22) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-1042/280, 3-4=-2500/473, 4-5=-2543/492, 5-6=-2422/403, 6-7=-2395/391, 7-8=-821/203, 2-14=-1053/251, 8-9=-988/237 BOT CHORD 12-13=-204/738, 11-12=-838/3273, 10-11=-141/590 WEBS 3-13=-484/41, 3-12=-336/2206, 4-12=-435/199, 5-12=-758/375, 5-11=-896/431, 6-11=-278/127, 7-11=-303/2162, 7-10=-598/90, 2-13=-139/662, 8-10=-178/628 NOTES-(12-13) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Bearing at joint(s) 14, 9 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 182 lb uplift at joint 14 and 202 lb uplift at joint 9. 8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 10) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 145 lb down and 131 lb up at 1-10-5, 83 lb down and 70 lb up at 3-11-1, 83 lb down and 70 lb up at 5-11-1, 83 lb down and 70 lb up at 7-11-1, 83 lb down and 70 lb up at 9-4-6, 83 lb down and 70 lb up at 10-7-10, 83 lb down and 70 lb up at 12-7-10, and 83 lb down and 70 lb up at 14-7-10, and 136 lb down and 109 lb up at 16-8-13 on top chord, and 61 lb down at 1-10-5, 34 lb down at 4-1-8, 34 lb down at 5-11-1, 34 lb down at 7-11-1, 34 lb down at 9-4-6, 34 lb down at 10-7-10, 34 lb down at 12-7-10, and 34 lb down at 14-7-10, and 56 lb down and 16 lb up at 16-7-10 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 11) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).Continued on page 2 June 25,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 2_HERITAGE_AT_SPRING~L Truss TG02 Truss Type Hip Girder Qty 1 Ply 1 2 Heritage at Spring Mill Job Reference (optional) I41794915 8.240 s Mar 9 2020 MiTek Industries, Inc. Wed Jun 24 18:33:03 2020 Page 2 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:EvWg2tiHQVSzJMSEDMv2ODzW2H3-?xC0UhIwsdGCvjJ8t1k?TlBp5BjFfLBb7Ir4y1z3_bE 12) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 13) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-2=-60, 2-3=-60, 3-7=-60, 7-8=-60, 12-14=-20, 11-12=-20, 9-11=-20 Concentrated Loads (lb) Vert: 3=-50(F) 7=-44(F) 12=-21(F) 13=-29(F) 10=-15(F) 15=-44(F) 16=-44(F) 17=-44(F) 18=-44(F) 19=-44(F) 20=-44(F) 21=-44(F) 22=-21(F) 23=-21(F) 24=-21(F) 25=-21(F) 26=-21(F) 27=-21(F) 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 2_HERITAGE_AT_SPRING~L Truss TG03 Truss Type Half Hip Girder Qty 2 Ply 1 2 Heritage at Spring Mill Job Reference (optional) I41794916 8.240 s Mar 9 2020 MiTek Industries, Inc. Wed Jun 24 18:33:03 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:EvWg2tiHQVSzJMSEDMv2ODzW2H3-?xC0UhIwsdGCvjJ8t1k?TlBz?By?fTeb7Ir4y1z3_bE Scale = 1:15.1 1 2 3 4 6 5 7 3x4 3x4 3x4 3x4 3x4 2-6-0 2-6-0 -0-11-0 0-11-0 2-0-0 2-0-0 2-6-0 0-6-0 1-1-02-5-08.00 12 Plate Offsets (X,Y)-- [3:0-2-0,0-2-3] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.08 0.02 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 -0.00 -0.00 (loc) 6 6 5 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 11 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x6 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 2-6-0 oc purlins, except end verticals, and 2-0-0 oc purlins: 3-4. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS. (size)5=Mechanical, 6=0-3-8 Max Horz 6=63(LC 5) Max Uplift 5=-43(LC 5), 6=-8(LC 8) Max Grav 5=95(LC 1), 6=168(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(11-12) 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) Provide adequate drainage to prevent water ponding. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 43 lb uplift at joint 5 and 8 lb uplift at joint 6. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 9) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 22 lb down and 43 lb up at 2-4-4 on top chord, and 14 lb down at 2-0-0 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 10) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). 11) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 12) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-2=-60, 2-3=-60, 3-4=-60, 5-6=-20 Concentrated Loads (lb) Vert: 4=-17(F) 7=-6(F) June 25,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 2_HERITAGE_AT_SPRING~L Truss TG04 Truss Type Hip Girder Qty 1 Ply 1 2 Heritage at Spring Mill Job Reference (optional) I41794917 8.240 s Mar 9 2020 MiTek Industries, Inc. Wed Jun 24 18:33:05 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:EvWg2tiHQVSzJMSEDMv2ODzW2H3-xKKnvNJAOFWw80TW_SmTYAG7??UK797ubcKB0vz3_bC Scale = 1:85.1 1 2 3 4 5 6 7 8 9 10 11 19 18 17 16 15 14 13 12 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 8x14 MT18HS 3x6 8x14 MT18HS 4x8 4x8 4x6 3x4 4x6 4x6 6x6 3x8 4x10 4x6 12x18 MT18HS 5x10 MT18HS 4x8 7-9-0 7-9-0 18-0-14 10-3-14 28-4-12 10-3-14 35-2-0 6-9-4 42-11-0 7-9-0 -0-11-0 0-11-0 4-0-4 4-0-4 7-9-0 3-8-12 14-7-4 6-10-4 21-5-8 6-10-4 28-3-12 6-10-4 35-2-0 6-10-4 38-10-12 3-8-12 42-11-0 4-0-4 1-1-06-0-116-3-01-1-06-0-118.00 12 Plate Offsets (X,Y)-- [2:Edge,0-5-8], [2:0-2-12,0-1-13], [4:0-10-9,Edge], [8:0-3-8,0-1-8], [9:0-6-8,0-1-12], [11:Edge,0-2-4], [11:0-1-12,0-1-3], [15:0-3-0,0-4-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.88 0.67 0.90 DEFL. Vert(LL) Vert(CT) Horz(CT) in 0.15 -0.22 0.04 (loc) 16-18 16-18 15 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 MT18HS Weight: 216 lb FT = 20% GRIP 169/123 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x6 SPF No.2 *Except* 14-17: 2x6 SP 2400F 2.0E WEBS 2x4 SPF-S Stud *Except* 5-18,6-15,8-13,11-12: 2x4 SPF No.2, 2-19: 2x6 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 3-9-10 oc purlins, except end verticals, and 2-0-0 oc purlins (4-1-9 max.): 4-9. BOT CHORD Structural wood sheathing directly applied or 6-0-0 oc bracing. WEBS 1 Row at midpt 5-18, 6-15, 8-15 REACTIONS. (size)15=0-3-8, 19=0-3-8, 12=0-3-8 Max Horz 19=119(LC 28) Max Uplift 15=-1463(LC 5), 19=-599(LC 8), 12=-158(LC 9) Max Grav 15=3427(LC 37), 19=1786(LC 35), 12=686(LC 22) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-843/311, 3-4=-2057/839, 4-5=-1715/741, 5-6=-1708/760, 6-8=-301/783, 8-9=-336/176, 9-10=-426/158, 10-11=-692/231, 2-19=-637/224, 11-12=-468/156 BOT CHORD 18-19=-665/1680, 16-18=-937/2000, 15-16=-582/1165, 13-15=-794/360, 12-13=-90/441 WEBS 3-18=-225/261, 4-18=-211/701, 5-18=-361/318, 5-16=-516/299, 6-16=-389/1189, 6-15=-2435/1114, 8-15=-1424/720, 8-13=-519/1371, 3-19=-1312/495, 10-12=-169/271 NOTES-(12-13) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 1463 lb uplift at joint 15, 599 lb uplift at joint 19 and 158 lb uplift at joint 12. 8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. Continued on page 2 June 25,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 2_HERITAGE_AT_SPRING~L Truss TG04 Truss Type Hip Girder Qty 1 Ply 1 2 Heritage at Spring Mill Job Reference (optional) I41794917 8.240 s Mar 9 2020 MiTek Industries, Inc. Wed Jun 24 18:33:06 2020 Page 2 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:EvWg2tiHQVSzJMSEDMv2ODzW2H3-PWu97jKo9YenmA1jY9Ii5OpIlPqZscN2pF4kYMz3_bB NOTES-(12-13) 10) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 99 lb down and 109 lb up at 8-0-12, 103 lb down and 109 lb up at 10-0-12, 103 lb down and 109 lb up at 12-0-12, 103 lb down and 109 lb up at 14-0-12, 103 lb down and 109 lb up at 16-0-12, 103 lb down and 109 lb up at 18-0-12, 103 lb down and 109 lb up at 20-0-12, 103 lb down and 109 lb up at 22-0-12, 103 lb down and 109 lb up at 24-0-12, 103 lb down and 109 lb up at 26-0-12, 103 lb down and 109 lb up at 28-0-12, 103 lb down and 109 lb up at 30-0-12, and 103 lb down and 109 lb up at 32-0-12, and 103 lb down and 109 lb up at 34-0-12 on top chord, and 117 lb down and 59 lb up at 2-0-12, 121 lb down and 65 lb up at 4-0-12, 128 lb down and 95 lb up at 6-0-12, 51 lb down and 48 lb up at 8-0-12, 51 lb down and 48 lb up at 10-0-12, 51 lb down and 48 lb up at 12-0-12, 51 lb down and 48 lb up at 14-0-12, 51 lb down and 48 lb up at 16-0-12, 51 lb down and 48 lb up at 18-0-12, 51 lb down and 48 lb up at 20-0-12, 51 lb down and 48 lb up at 22-0-12, 51 lb down and 48 lb up at 24-0-12, 51 lb down and 48 lb up at 26-0-12, 51 lb down and 48 lb up at 28-0-12, 51 lb down and 48 lb up at 30-0-12, 51 lb down and 48 lb up at 32-0-12, 51 lb down and 48 lb up at 34-0-12, 146 lb down and 109 lb up at 36-0-12, 121 lb down and 75 lb up at 38-0-12, and 121 lb down and 65 lb up at 38-10-4, and 117 lb down and 59 lb up at 40-10-4 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 11) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). 12) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 13) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-2=-60, 2-4=-60, 4-9=-60, 9-11=-60, 12-19=-20 Concentrated Loads (lb) Vert: 17=-19(F) 16=-19(F) 8=-46(F) 20=-46(F) 21=-46(F) 22=-46(F) 23=-46(F) 24=-46(F) 25=-46(F) 26=-46(F) 27=-46(F) 28=-46(F) 29=-46(F) 30=-46(F) 31=-46(F) 32=-46(F) 33=-117(F) 34=-121(F) 35=-121(F) 36=-19(F) 37=-19(F) 38=-19(F) 40=-19(F) 42=-19(F) 44=-19(F) 46=-19(F) 47=-19(F) 48=-19(F) 49=-19(F) 50=-19(F) 51=-19(F) 52=-121(F) 53=-121(F) 54=-121(F) 55=-117(F) 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 2_HERITAGE_AT_SPRING~L Truss TG05 Truss Type Half Hip Girder Qty 2 Ply 1 2 Heritage at Spring Mill Job Reference (optional) I41794918 8.240 s Mar 9 2020 MiTek Industries, Inc. Wed Jun 24 18:33:07 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:EvWg2tiHQVSzJMSEDMv2ODzW2H3-ujRXK3LQwsneOKcv6spxebLeVpJ0bH0B2vpI5oz3_bA Scale = 1:14.9 1 2 3 4 7 6 5 8 9 5x6 3x4 3x4 3x4 3x4 4x6 2-0-0 2-0-0 4-0-0 2-0-0 -0-11-0 0-11-0 0-8-9 0-8-9 4-0-0 3-3-7 1-7-02-3-32-5-02-3-314.00 12 Plate Offsets (X,Y)-- [3:0-3-10,0-2-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.17 0.01 0.04 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 -0.00 -0.00 (loc) 7 7 5 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 22 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x6 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 4-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins: 3-4. BOT CHORD Structural wood sheathing directly applied or 6-0-0 oc bracing. REACTIONS. (size)5=Mechanical, 7=0-3-8 Max Horz 7=64(LC 5) Max Uplift 5=-39(LC 5), 7=-58(LC 8) Max Grav 5=137(LC 22), 7=187(LC 45) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(12-13) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Refer to girder(s) for truss to truss connections. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 39 lb uplift at joint 5 and 58 lb uplift at joint 7. 8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 10) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 17 lb down and 113 lb up at 0-8-9, and 48 lb down and 31 lb up at 1-11-4 on top chord, and 15 lb down and 18 lb up at 0-8-9, and 11 lb down and 11 lb up at 1-11-4 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 11) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). 12) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 13) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-2=-60, 2-3=-60, 3-4=-60, 5-7=-20 Continued on page 2 June 25,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 2_HERITAGE_AT_SPRING~L Truss TG05 Truss Type Half Hip Girder Qty 2 Ply 1 2 Heritage at Spring Mill Job Reference (optional) I41794918 8.240 s Mar 9 2020 MiTek Industries, Inc. Wed Jun 24 18:33:07 2020 Page 2 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:EvWg2tiHQVSzJMSEDMv2ODzW2H3-ujRXK3LQwsneOKcv6spxebLeVpJ0bH0B2vpI5oz3_bA LOAD CASE(S) Standard Concentrated Loads (lb) Vert: 3=36(F) 6=1(F) 9=7(F) 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 2_HERITAGE_AT_SPRING~L Truss TG06 Truss Type Roof Special Girder Qty 1 Ply 1 2 Heritage at Spring Mill Job Reference (optional) I41794919 8.240 s Mar 9 2020 MiTek Industries, Inc. Wed Jun 24 18:33:09 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:EvWg2tiHQVSzJMSEDMv2ODzW2H3-q5ZIllMhST1LdemIDHrPj0RvwctS32IUWDIO9gz3_b8 Scale = 1:46.8 1 2 3 4 5 6 7 8 16 15 14 13 12 11 10 9 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 5x8 5x8 5x12 6x6 4x6 3x12 4x6 5x8 3x6 3x4 3x4 4x8 2x4 4x6 3x6 5x8 3-2-10 3-2-10 10-8-13 7-6-3 18-3-0 7-6-3 19-8-8 1-5-8 23-9-8 4-1-0 25-10-8 2-1-0 3-2-10 3-2-10 8-2-12 5-0-2 13-2-14 5-0-2 18-3-0 5-0-2 19-8-8 1-5-8 23-9-8 4-1-0 25-10-8 2-1-0 4-1-46-0-115-1-06-3-02-10-36-0-118.00 12 14.00 12 Plate Offsets (X,Y)-- [7:0-4-0,Edge], [8:0-2-8,0-1-8], [9:Edge,0-3-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.50 0.53 0.63 DEFL. Vert(LL) Vert(CT) Horz(CT) in 0.10 -0.14 0.03 (loc) 12-14 12-14 9 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 150 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 *Except* 1-2,5-6: 2x6 SPF No.2 BOT CHORD 2x6 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 5-1-7 oc purlins, except end verticals, and 2-0-0 oc purlins (4-1-7 max.): 2-5, 6-7. BOT CHORD Structural wood sheathing directly applied or 7-7-12 oc bracing. WEBS 1 Row at midpt 3-15, 6-10 REACTIONS. (size)16=0-3-8, 9=Mechanical Max Horz 16=-134(LC 4) Max Uplift 16=-638(LC 5), 9=-689(LC 9) Max Grav 16=1597(LC 45), 9=1782(LC 44) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-1080/476, 2-3=-900/420, 3-4=-1943/857, 4-5=-1736/771, 5-6=-2008/858, 6-7=-780/352, 7-8=-1147/469, 1-16=-1596/651, 8-9=-1775/705 BOT CHORD 14-15=-832/1728, 12-14=-937/2017, 11-12=-764/1773, 10-11=-767/1779 WEBS 2-15=-73/272, 3-15=-1267/614, 3-14=-192/612, 4-12=-406/254, 5-12=-263/771, 6-10=-1553/680, 7-10=-314/676, 1-15=-585/1326, 8-10=-489/1189 NOTES-(12-13) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Refer to girder(s) for truss to truss connections. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 638 lb uplift at joint 16 and 689 lb uplift at joint 9. 8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 10) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 100 lb down and 109 lb up at 3-7-4, 103 lb down and 109 lb up at 5-7-4, 103 lb down and 109 lb up at 7-7-4, 103 lb down and 109 lb up at 9-7-4, 103 lb down and 109 lb up at 11-7-4, 103 lb down and 109 lb up at 13-7-4, and 103 lb down and 109 lb up at 15-7-4, and 101 lb down and 109 lb up at 17-7-4 on top chord, and 28 lb up at 1-7-4, 51 lb down and 48 lb up at 3-7-4, 51 lb down and 48 lb up at 5-7-4, 51 lb down and 48 lb up at 7-7-4, 51 lb down and 48 lb up at 9-7-4, 51 lb down and 48 lb up at 11-7-4, 51 lb down and 48 lb up at 13-7-4, 51 lb down and 48 lb up at 15-7-4, 51 lb down and 48 lb up at 17-7-4, 165 lb down and 127 lb up at 19-7-4, and 165 lb down and 127 lb up at 21-7-4, and 141 lb down and 110 lb up at 23-7-4 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 11) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).Continued on page 2 June 25,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 2_HERITAGE_AT_SPRING~L Truss TG06 Truss Type Roof Special Girder Qty 1 Ply 1 2 Heritage at Spring Mill Job Reference (optional) I41794919 8.240 s Mar 9 2020 MiTek Industries, Inc. Wed Jun 24 18:33:09 2020 Page 2 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:EvWg2tiHQVSzJMSEDMv2ODzW2H3-q5ZIllMhST1LdemIDHrPj0RvwctS32IUWDIO9gz3_b8 12) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 13) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-2=-60, 2-5=-60, 5-6=-60, 6-7=-60, 7-8=-60, 9-16=-20 Concentrated Loads (lb) Vert: 13=-19(F) 15=-19(F) 11=-119(F) 10=-121(F) 17=-46(F) 18=-46(F) 19=-46(F) 20=-46(F) 21=-46(F) 22=-46(F) 23=-46(F) 24=-46(F) 25=25(F) 26=-19(F) 28=-19(F) 30=-19(F) 31=-19(F) 34=-19(F) 35=-19(F) 36=-119(F) 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 2_HERITAGE_AT_SPRING~L Truss TG07 Truss Type Hip Girder Qty 1 Ply 2 2 Heritage at Spring Mill Job Reference (optional) I41794920 8.240 s Mar 9 2020 MiTek Industries, Inc. Wed Jun 24 18:33:10 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:EvWg2tiHQVSzJMSEDMv2ODzW2H3-II7gy5NJDn9CFnLUn?MeFEz7o0INoZ8dkt2yi7z3_b7 Scale = 1:17.6 1 2 3 4 7 6 5 8 9 10 11 12 13 14 15 3x6 4x6 4x6 3x6 3x4 3x4 6x16 3-7-12 3-7-12 7-3-8 3-7-12 0-10-0 0-10-0 6-5-8 5-7-8 7-3-8 0-10-0 1-7-02-6-111-7-02-6-1114.00 12 Plate Offsets (X,Y)-- [2:0-4-8,0-1-12], [3:0-4-8,0-1-12], [6:0-8-0,0-4-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.30 0.23 0.33 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.02 -0.03 -0.00 (loc) 5-6 5-6 5 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 82 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x6 SP 2400F 2.0E WEBS 2x4 SPF-S Stud *Except* 1-6,4-6: 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 2-3. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS. (size)7=0-5-8, 5=0-3-8 Max Horz 7=50(LC 5) Max Uplift 7=-446(LC 4), 5=-320(LC 5) Max Grav 7=1174(LC 44), 5=2007(LC 44) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-1196/410, 2-3=-1753/525, 3-4=-1194/409, 1-7=-1208/409, 4-5=-1207/408 WEBS 2-6=-342/1269, 3-6=-341/1269, 1-6=-284/802, 4-6=-283/801 NOTES-(12-13) 1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows: Top chords connected as follows: 2x4 - 1 row at 0-9-0 oc. Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-9-0 oc. Webs connected as follows: 2x4 - 1 row at 0-9-0 oc, 2x3 - 1 row at 0-9-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Unbalanced roof live loads have been considered for this design. 4) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 5) Provide adequate drainage to prevent water ponding. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 446 lb uplift at joint 7 and 320 lb uplift at joint 5. 9) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 10) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 11) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 71 lb down and 157 lb up at 0-10-0, 41 lb down and 82 lb up at 2-10-12, and 41 lb down and 82 lb up at 4-4-12, and 69 lb down and 157 lb up at 6-5-8 on top chord, and 56 lb down and 66 lb up at 0-10-0, 35 lb down and 41 lb up at 2-10-12, 1672 lb down and 709 lb up at 4-0-12, 35 lb down and 41 lb up at 4-4-12, and 1116 lb down at 6-0-12, and 56 lb down and 66 lb up at 6-3-11 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. Continued on page 2 June 25,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 2_HERITAGE_AT_SPRING~L Truss TG07 Truss Type Hip Girder Qty 1 Ply 2 2 Heritage at Spring Mill Job Reference (optional) I41794920 8.240 s Mar 9 2020 MiTek Industries, Inc. Wed Jun 24 18:33:10 2020 Page 2 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:EvWg2tiHQVSzJMSEDMv2ODzW2H3-II7gy5NJDn9CFnLUn?MeFEz7o0INoZ8dkt2yi7z3_b7 12) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 13) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-2=-60, 2-3=-60, 3-4=-60, 5-7=-20 Concentrated Loads (lb) Vert: 2=52(F) 3=52(F) 8=27(F) 9=27(F) 10=8(F) 11=4(F) 12=-1516(B) 13=4(F) 14=-999(F=4, B=-1003) 15=4(F) 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 2_HERITAGE_AT_SPRING~L Truss TG08 Truss Type Flat Girder Qty 1 Ply 2 2 Heritage at Spring Mill Job Reference (optional) I41794921 8.240 s Mar 9 2020 MiTek Industries, Inc. Wed Jun 24 18:33:11 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:EvWg2tiHQVSzJMSEDMv2ODzW2H3-mUh2AQOx_5H3sxwgLittoRWMKQhwX5YnzXnVEZz3_b6 Scale: 1"=1' 1 2 4 3 5 3x4 3x4 3x4 4x6 2-10-0 2-10-0 2-10-0 2-10-0 1-9-15LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.05 0.02 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 -0.00 -0.00 (loc) 4 4 3 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 26 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x6 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD 2-0-0 oc purlins: 1-2, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS. (size)4=0-3-8, 3=0-3-8 Max Horz 4=-38(LC 4) Max Uplift 4=-15(LC 4), 3=-15(LC 5) Max Grav 4=103(LC 1), 3=103(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(11-12) 1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows: Top chords connected as follows: 2x4 - 1 row at 0-9-0 oc. Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-9-0 oc. Webs connected as follows: 2x4 - 1 row at 0-9-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 4) Provide adequate drainage to prevent water ponding. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 15 lb uplift at joint 4 and 15 lb uplift at joint 3. 8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 10) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 10 lb down at 1-2-12 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 11) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 12) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-2=-60, 3-4=-20 Continued on page 2 June 25,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 2_HERITAGE_AT_SPRING~L Truss TG08 Truss Type Flat Girder Qty 1 Ply 2 2 Heritage at Spring Mill Job Reference (optional) I41794921 8.240 s Mar 9 2020 MiTek Industries, Inc. Wed Jun 24 18:33:11 2020 Page 2 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:EvWg2tiHQVSzJMSEDMv2ODzW2H3-mUh2AQOx_5H3sxwgLittoRWMKQhwX5YnzXnVEZz3_b6 LOAD CASE(S) Standard Concentrated Loads (lb) Vert: 5=-3(F) 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 2_HERITAGE_AT_SPRING~L Truss TG15 Truss Type Hip Girder Qty 1 Ply 1 2 Heritage at Spring Mill Job Reference (optional) I41794922 8.240 s Mar 9 2020 MiTek Industries, Inc. Wed Jun 24 18:33:13 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:EvWg2tiHQVSzJMSEDMv2ODzW2H3-itpob6PBViXn6F43S7wLtsbVQDBW?nl4QrGcISz3_b4 Scale = 1:57.7 1 2 3 4 5 6 7 16 15 14 13 12 11 10 9 8 17 18 19 20 21 22 8x10 5x6 4x8 3x12 8x8 4x6 5x12 5x12 4x10 2x4 3x8 2x4 5x8 3x12 3x4 4x6 3-2-6 3-2-6 6-1-4 2-10-14 11-9-0 5-7-12 16-9-11 5-0-11 21-8-11 4-10-15 26-9-6 5-0-11 30-0-0 3-2-10 6-1-4 6-1-4 11-9-0 5-7-12 16-9-11 5-0-11 21-8-11 4-10-15 26-9-6 5-0-11 30-0-0 3-2-10 1-3-149-1-144-1-42-10-146-3-08.00 12 6.00 12 Plate Offsets (X,Y)-- [1:0-2-8,Edge], [3:0-3-0,0-2-3], [6:0-6-4,0-2-0], [9:0-3-8,0-1-8], [15:0-5-8,0-3-0], [16:0-0-0,0-0-2] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.85 0.78 0.92 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.13 -0.28 0.18 (loc) 13-14 13-14 8 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 159 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x6 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 3-3-11 oc purlins, except end verticals, and 2-0-0 oc purlins (4-5-10 max.): 3-6. BOT CHORD Structural wood sheathing directly applied or 9-11-5 oc bracing. WEBS 1 Row at midpt 2-13 REACTIONS. (size)16=0-3-8, 8=0-3-8 Max Horz 16=186(LC 5) Max Uplift 16=-88(LC 8), 8=-176(LC 5) Max Grav 16=1243(LC 25), 8=1285(LC 25) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-2465/322, 2-3=-1983/319, 3-4=-1593/283, 4-5=-1331/265, 5-6=-1331/265, 6-7=-824/147, 1-16=-1304/202, 7-8=-1259/193 BOT CHORD 15-16=-244/412, 14-15=-543/3207, 13-14=-478/2785, 11-13=-370/1630, 10-11=-370/1630, 9-10=-148/637 WEBS 2-15=-1382/183, 2-14=-160/1423, 2-13=-1298/260, 3-13=-114/759, 4-11=-44/260, 4-10=-473/89, 5-10=-309/85, 6-10=-252/1075, 6-9=-633/147, 1-15=-154/1681, 7-9=-203/986 NOTES-(12-13) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Bearing at joint(s) 16 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 88 lb uplift at joint 16 and 176 lb uplift at joint 8. 8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 10) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 51 lb down and 48 lb up at 12-2-0, 51 lb down and 48 lb up at 14-2-0, 51 lb down and 48 lb up at 16-2-0, 51 lb down and 48 lb up at 18-2-0, 51 lb down and 48 lb up at 20-2-0, 51 lb down and 48 lb up at 22-2-0, and 51 lb down and 48 lb up at 24-2-0, and 51 lb down and 48 lb up at 26-2-0 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 11) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). Continued on page 2 June 25,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 2_HERITAGE_AT_SPRING~L Truss TG15 Truss Type Hip Girder Qty 1 Ply 1 2 Heritage at Spring Mill Job Reference (optional) I41794922 8.240 s Mar 9 2020 MiTek Industries, Inc. Wed Jun 24 18:33:13 2020 Page 2 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:EvWg2tiHQVSzJMSEDMv2ODzW2H3-itpob6PBViXn6F43S7wLtsbVQDBW?nl4QrGcISz3_b4 12) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 13) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-3=-60, 3-6=-60, 6-7=-60, 14-16=-20, 8-14=-20 Concentrated Loads (lb) Vert: 12=-19(F) 13=-19(F) 17=-19(F) 18=-19(F) 19=-19(F) 20=-19(F) 21=-19(F) 22=-19(F) 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 2_HERITAGE_AT_SPRING~L Truss V01 Truss Type GABLE Qty 1 Ply 1 2 Heritage at Spring Mill Job Reference (optional) I41794923 8.240 s Mar 9 2020 MiTek Industries, Inc. Wed Jun 24 18:33:13 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:EvWg2tiHQVSzJMSEDMv2ODzW2H3-itpob6PBViXn6F43S7wLtsbepDLP?zZ4QrGcISz3_b4 Scale = 1:45.9 1 2 3 4 5 8 7 69103x4 4x6 3x4 2x4 2x4 2x4 2x4 2x4 12-4-13 12-4-13 6-2-7 6-2-7 12-4-13 6-2-7 0-0-47-2-130-0-414.00 12 Plate Offsets (X,Y)-- [3:0-2-4,0-2-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.31 0.14 0.16 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 38 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x3 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 12-4-13. (lb) - Max Horz 1=-130(LC 6) Max Uplift All uplift 100 lb or less at joint(s) 1, 5 except 8=-152(LC 10), 6=-152(LC 11) Max Grav All reactions 250 lb or less at joint(s) 1, 5 except 7=335(LC 17), 8=377(LC 17), 6=376(LC 18) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-8=-254/194, 4-6=-254/194 NOTES-(8-9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) 0-3-5 to 3-3-5, Exterior(2R) 3-3-5 to 9-1-8, Exterior(2E) 9-1-8 to 12-1-8 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 5 except (jt=lb) 8=152, 6=152. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). June 25,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 2_HERITAGE_AT_SPRING~L Truss V02 Truss Type GABLE Qty 1 Ply 1 2 Heritage at Spring Mill Job Reference (optional) I41794924 8.240 s Mar 9 2020 MiTek Industries, Inc. Wed Jun 24 18:33:14 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:EvWg2tiHQVSzJMSEDMv2ODzW2H3-B3MBoSQpG0fejPfF0rRaQ48mGdfGkQJDfV09ruz3_b3 Scale = 1:37.8 1 2 3 43x6 6x6 3x6 2x4 10-1-6 10-1-6 5-0-11 5-0-11 10-1-6 5-0-11 0-0-45-10-130-0-414.00 12 Plate Offsets (X,Y)-- [2:0-2-0,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.46 0.23 0.13 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 28 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x3 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=10-1-6, 3=10-1-6, 4=10-1-6 Max Horz 1=-105(LC 6) Max Uplift 1=-7(LC 11) Max Grav 1=211(LC 1), 3=211(LC 1), 4=344(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(8-9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) 0-3-5 to 3-3-5, Exterior(2R) 3-3-5 to 6-10-1, Exterior(2E) 6-10-1 to 9-10-1 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). June 25,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 2_HERITAGE_AT_SPRING~L Truss V03 Truss Type GABLE Qty 1 Ply 1 2 Heritage at Spring Mill Job Reference (optional) I41794925 8.240 s Mar 9 2020 MiTek Industries, Inc. Wed Jun 24 18:33:15 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:EvWg2tiHQVSzJMSEDMv2ODzW2H3-fFwZ0oRR1JnVLZERaYypyHgxo1?jTveNu9ljNKz3_b2 Scale = 1:30.5 1 2 3 43x4 3x4 3x4 2x4 7-9-15 7-9-15 3-11-0 3-11-0 7-9-15 3-11-0 0-0-44-6-130-0-414.00 12 Plate Offsets (X,Y)-- [1:0-3-1,Edge], [3:0-1-2,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.47 0.22 0.06 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 19 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x3 SPF No.2 BOT CHORD 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=7-9-15, 3=7-9-15, 4=7-9-15 Max Horz 1=81(LC 9) Max Uplift 1=-24(LC 11), 3=-16(LC 10) Max Grav 1=183(LC 1), 3=183(LC 1), 4=228(LC 3) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(8-9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) 0-2-11 to 3-2-11, Exterior(2R) 3-2-11 to 4-7-4, Exterior(2E) 4-7-4 to 7-7-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). June 25,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 2_HERITAGE_AT_SPRING~L Truss V04 Truss Type GABLE Qty 1 Ply 1 2 Heritage at Spring Mill Job Reference (optional) I41794926 8.240 s Mar 9 2020 MiTek Industries, Inc. Wed Jun 24 18:33:15 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:EvWg2tiHQVSzJMSEDMv2ODzW2H3-fFwZ0oRR1JnVLZERaYypyHg?s1wbTvcNu9ljNKz3_b2 Scale = 1:22.1 1 2 3 3x4 3x4 3x4 5-6-8 5-6-8 2-9-4 2-9-4 5-6-8 2-9-4 0-0-43-2-130-0-414.00 12 Plate Offsets (X,Y)-- [1:0-3-1,Edge], [2:0-0-0,0-0-0], [3:0-1-2,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.21 0.54 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 11 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x3 SPF No.2 BOT CHORD 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 5-6-8 oc purlins. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=5-6-8, 3=5-6-8 Max Horz 1=-56(LC 6) Max Grav 1=204(LC 1), 3=204(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(7-8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). June 25,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 2_HERITAGE_AT_SPRING~L Truss V05 Truss Type Valley Qty 1 Ply 1 2 Heritage at Spring Mill Job Reference (optional) I41794927 8.240 s Mar 9 2020 MiTek Industries, Inc. Wed Jun 24 18:33:16 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:UBWbwwZ3HZkShWUqTJOC34z3?4W-7RUxD8S4odvMzioe8FT2VVDC0ROqCMjW7pVGvmz3_b1 Scale = 1:12.4 1 2 3 4 3x4 3x4 3x4 2x4 0-0-3 0-0-3 3-3-2 3-2-14 1-7-9 1-7-9 3-3-2 1-7-9 0-0-41-10-130-0-414.00 12 Plate Offsets (X,Y)-- [1:0-3-1,Edge], [3:0-1-2,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.06 0.03 0.01 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 7 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x3 SPF No.2 BOT CHORD 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 3-3-2 oc purlins. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=3-2-11, 3=3-2-11, 4=3-2-11 Max Horz 1=31(LC 9) Max Uplift 1=-9(LC 11), 3=-6(LC 10) Max Grav 1=70(LC 1), 3=70(LC 1), 4=87(LC 3) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(8-9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). June 25,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 2_HERITAGE_AT_SPRING~L Truss V06 Truss Type GABLE Qty 1 Ply 1 2 Heritage at Spring Mill Job Reference (optional) I41794928 8.240 s Mar 9 2020 MiTek Industries, Inc. Wed Jun 24 18:33:17 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:EvWg2tiHQVSzJMSEDMv2ODzW2H3-be2JQUSiZx1DbsNqhz_H1imHPrVBxo5fLTEpRDz3_b0 Scale = 1:28.1 1 2 3 3x4 3x4 3x4 7-4-7 7-4-7 3-8-4 3-8-4 7-4-7 3-8-4 0-0-44-3-100-0-414.00 12 Plate Offsets (X,Y)-- [2:0-0-0,0-0-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.40 0.98 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 16 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x3 SPF No.2 BOT CHORD 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Structural wood sheathing directly applied. REACTIONS. (size)1=7-4-7, 3=7-4-7 Max Horz 1=75(LC 7) Max Grav 1=273(LC 1), 3=273(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(7-8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) 0-3-5 to 3-3-5, Exterior(2R) 3-3-5 to 4-1-2, Exterior(2E) 4-1-2 to 7-1-2 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). June 25,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 2_HERITAGE_AT_SPRING~L Truss V07 Truss Type Valley Qty 1 Ply 1 2 Heritage at Spring Mill Job Reference (optional) I41794929 8.240 s Mar 9 2020 MiTek Industries, Inc. Wed Jun 24 18:33:17 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:EvWg2tiHQVSzJMSEDMv2ODzW2H3-be2JQUSiZx1DbsNqhz_H1imLzredxo5fLTEpRDz3_b0 Scale = 1:20.7 1 2 3 3x4 3x4 3x4 5-0-13 5-0-13 5-1-0 0-0-3 2-6-8 2-6-8 5-1-0 2-6-8 0-0-42-11-100-0-414.00 12 Plate Offsets (X,Y)-- [1:0-3-1,Edge], [2:0-0-0,0-0-0], [3:0-1-2,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.17 0.44 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 10 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x3 SPF No.2 BOT CHORD 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 5-1-0 oc purlins. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=5-0-10, 3=5-0-10 Max Horz 1=51(LC 7) Max Grav 1=185(LC 1), 3=185(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(7-8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). June 25,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 2_HERITAGE_AT_SPRING~L Truss V08 Truss Type Valley Qty 1 Ply 1 2 Heritage at Spring Mill Job Reference (optional) I41794930 8.240 s Mar 9 2020 MiTek Industries, Inc. Wed Jun 24 18:33:18 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:EvWg2tiHQVSzJMSEDMv2ODzW2H3-3qcheqTKKE94C0y0FgVWawIYoE3BgFLpa7_N_fz3_b? Scale = 1:11.0 1 2 3 3x4 3x4 3x4 0-0-3 0-0-3 2-9-10 2-9-6 1-4-13 1-4-13 2-9-10 1-4-13 0-0-41-7-100-0-414.00 12 Plate Offsets (X,Y)-- [1:0-3-1,Edge], [2:0-0-0,0-0-0], [3:0-1-2,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.04 0.10 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 5 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x3 SPF No.2 BOT CHORD 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 2-9-10 oc purlins. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=2-9-3, 3=2-9-3 Max Horz 1=-26(LC 6) Max Grav 1=94(LC 1), 3=94(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(7-8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). June 25,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 2_HERITAGE_AT_SPRING~L Truss V09 Truss Type GABLE Qty 1 Ply 1 2 Heritage at Spring Mill Job Reference (optional) I41794931 8.240 s Mar 9 2020 MiTek Industries, Inc. Wed Jun 24 18:33:19 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:EvWg2tiHQVSzJMSEDMv2ODzW2H3-X0A4r9Uy5YHxqAXDpO1l77rfOeOwPe8ypnjwW5z3_b_ Scale: 1/4"=1' 1 2 3 4 5 9 8 7 61011 3x4 3x4 4x6 3x4 2x4 2x4 2x4 2x4 2x4 10-9-0 10-9-0 4-6-8 4-6-8 10-9-0 6-2-8 1-11-57-2-140-0-414.00 12 Plate Offsets (X,Y)-- [3:0-2-4,0-2-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.31 0.14 0.29 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 36 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x3 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 10-9-0. (lb) - Max Horz 9=-145(LC 6) Max Uplift All uplift 100 lb or less at joint(s) 5 except 9=-298(LC 17), 8=-282(LC 10), 6=-152(LC 11) Max Grav All reactions 250 lb or less at joint(s) 9, 5 except 7=450(LC 18), 8=573(LC 17), 6=379(LC 18) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-8=-353/306, 4-6=-258/194 NOTES-(8-9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) 0-1-4 to 3-1-4, Exterior(2R) 3-1-4 to 7-5-10, Exterior(2E) 7-5-10 to 10-5-10 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5 except (jt=lb) 9=298, 8=282, 6=152. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). June 25,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 2_HERITAGE_AT_SPRING~L Truss V10 Truss Type GABLE Qty 1 Ply 1 2 Heritage at Spring Mill Job Reference (optional) I41794932 8.240 s Mar 9 2020 MiTek Industries, Inc. Wed Jun 24 18:33:19 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:EvWg2tiHQVSzJMSEDMv2ODzW2H3-X0A4r9Uy5YHxqAXDpO1l77rb8eLhPgYypnjwW5z3_b_ Scale = 1:39.5 1 2 3 43x6 3x4 2x4 5x6 9-7-4 9-7-4 4-6-8 4-6-8 9-7-4 5-0-12 0-7-55-10-140-0-414.00 12 Plate Offsets (X,Y)-- [1:Edge,0-0-8], [2:0-2-2,Edge], [3:0-1-2,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.51 0.34 0.13 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 25 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud *Except* 2-3: 2x3 SPF No.2 BOT CHORD 2x3 SPF No.2 OTHERS 2x3 SPF No.2 WEDGE Left: 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=9-7-4, 3=9-7-4, 4=9-7-4 Max Horz 1=105(LC 9) Max Uplift 1=-15(LC 11), 3=-3(LC 10) Max Grav 1=204(LC 1), 3=219(LC 1), 4=315(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(8-9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) 0-1-12 to 3-1-12, Exterior(2R) 3-1-12 to 6-4-9, Exterior(2E) 6-4-9 to 9-4-9 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). June 25,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 2_HERITAGE_AT_SPRING~L Truss V11 Truss Type Valley Qty 1 Ply 1 2 Heritage at Spring Mill Job Reference (optional) I41794933 8.240 s Mar 9 2020 MiTek Industries, Inc. Wed Jun 24 18:33:20 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:EvWg2tiHQVSzJMSEDMv2ODzW2H3-?DkS3VVassPoSK6PN5Y_fLOnW2it89t61RTU1Yz3_az Scale = 1:30.6 1 2 3 43x4 3x4 3x4 2x4 0-0-3 0-0-3 7-10-2 7-9-14 3-11-1 3-11-1 7-10-2 3-11-1 0-0-44-6-140-0-414.00 12 Plate Offsets (X,Y)-- [1:0-3-1,Edge], [3:0-1-2,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.47 0.22 0.06 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 19 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x3 SPF No.2 BOT CHORD 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=7-9-11, 3=7-9-11, 4=7-9-11 Max Horz 1=-81(LC 8) Max Uplift 1=-24(LC 11), 3=-16(LC 10) Max Grav 1=184(LC 1), 3=184(LC 1), 4=229(LC 3) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(8-9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) 0-2-11 to 3-2-11, Exterior(2R) 3-2-11 to 4-7-6, Exterior(2E) 4-7-6 to 7-7-6 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). June 25,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 2_HERITAGE_AT_SPRING~L Truss V12 Truss Type Valley Qty 1 Ply 1 2 Heritage at Spring Mill Job Reference (optional) I41794934 8.240 s Mar 9 2020 MiTek Industries, Inc. Wed Jun 24 18:33:21 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:EvWg2tiHQVSzJMSEDMv2ODzW2H3-TPIqGrWCd9Xf3Uhbwp3DCYw0KSzytc5FG5C1Z_z3_ay Scale = 1:22.2 1 2 3 3x4 3x4 3x4 0-0-3 0-0-3 5-6-11 5-6-7 2-9-5 2-9-5 5-6-11 2-9-5 0-0-43-2-140-0-414.00 12 Plate Offsets (X,Y)-- [1:0-3-1,Edge], [2:0-0-0,0-0-0], [3:0-1-2,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.21 0.55 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 11 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x3 SPF No.2 BOT CHORD 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 5-6-11 oc purlins. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=5-6-4, 3=5-6-4 Max Horz 1=-56(LC 6) Max Grav 1=204(LC 1), 3=204(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(7-8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). June 25,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 2_HERITAGE_AT_SPRING~L Truss V13 Truss Type Valley Qty 1 Ply 1 2 Heritage at Spring Mill Job Reference (optional) I41794935 8.240 s Mar 9 2020 MiTek Industries, Inc. Wed Jun 24 18:33:21 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:nvRCrVWLYVz8PozCMqfRhAyef5_-TPIqGrWCd9Xf3Uhbwp3DCYw3kS37tc5FG5C1Z_z3_ay Scale = 1:12.4 1 2 3 3x4 3x4 3x4 0-0-3 0-0-3 3-3-4 3-3-0 1-7-10 1-7-10 3-3-4 1-7-10 0-0-41-10-140-0-414.00 12 Plate Offsets (X,Y)-- [1:0-3-1,Edge], [2:0-0-0,0-0-0], [3:0-1-2,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.06 0.15 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 6 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x3 SPF No.2 BOT CHORD 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 3-3-4 oc purlins. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=3-2-13, 3=3-2-13 Max Horz 1=-31(LC 6) Max Grav 1=113(LC 1), 3=113(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(7-8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). June 25,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 2_HERITAGE_AT_SPRING~L Truss V14 Truss Type GABLE Qty 1 Ply 1 2 Heritage at Spring Mill Job Reference (optional) I41794936 8.240 s Mar 9 2020 MiTek Industries, Inc. Wed Jun 24 18:33:22 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:EvWg2tiHQVSzJMSEDMv2ODzW2H3-ybrCUBWrOTgVhdGoUWaSkmTAXsMYc1cOVlya6Qz3_ax Scale = 1:39.2 1 2 3 4 5 10 9 8 7 6 11 12 13 14 153x4 4x6 3x4 3x4 3x4 2x4 2x4 2x4 2x4 2x4 16-8-4 16-8-4 9-7-4 9-7-4 16-8-4 7-1-0 0-0-46-4-131-8-38.00 12 Plate Offsets (X,Y)-- [6:Edge,0-2-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.31 0.33 0.18 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 6 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 47 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x3 SPF No.2 WEBS 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 16-8-4. (lb) - Max Horz 1=123(LC 7) Max Uplift All uplift 100 lb or less at joint(s) 1, 6, 10, 7 Max Grav All reactions 250 lb or less at joint(s) 1, 6 except 8=384(LC 17), 10=547(LC 17), 7=396(LC 18) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-10=-341/144 NOTES-(8-9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) 0-5-0 to 3-5-0, Interior(1) 3-5-0 to 6-7-4, Exterior(2R) 6-7-4 to 12-7-4, Interior(1) 12-7-4 to 13-7-0, Exterior(2E) 13-7-0 to 16-7-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 6, 10, 7. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). June 25,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 2_HERITAGE_AT_SPRING~L Truss V15 Truss Type GABLE Qty 1 Ply 1 2 Heritage at Spring Mill Job Reference (optional) I41794937 8.240 s Mar 9 2020 MiTek Industries, Inc. Wed Jun 24 18:33:23 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:EvWg2tiHQVSzJMSEDMv2ODzW2H3-QoPahXXT9noMJnr_2E5hHz0FYFk1LVuYkPh8esz3_aw Scale = 1:25.8 1 2 3 4 5 6 3x6 8x8 3x6 2x4 12-2-8 12-2-8 6-1-4 6-1-4 12-2-8 6-1-4 0-0-44-0-130-0-48.00 12 Plate Offsets (X,Y)-- [2:Edge,0-3-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.68 0.25 0.11 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 30 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=12-2-8, 3=12-2-8, 4=12-2-8 Max Horz 1=-67(LC 6) Max Uplift 1=-7(LC 10), 3=-14(LC 11) Max Grav 1=210(LC 23), 3=210(LC 24), 4=481(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-4=-298/71 NOTES-(8-9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) 0-5-12 to 3-5-12, Exterior(2R) 3-5-12 to 8-8-11, Exterior(2E) 8-8-11 to 11-8-11 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). June 25,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 2_HERITAGE_AT_SPRING~L Truss V16 Truss Type Valley Qty 1 Ply 1 2 Heritage at Spring Mill Job Reference (optional) I41794938 8.240 s Mar 9 2020 MiTek Industries, Inc. Wed Jun 24 18:33:23 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:EvWg2tiHQVSzJMSEDMv2ODzW2H3-QoPahXXT9noMJnr_2E5hHz0NjFhMLWaYkPh8esz3_aw Scale = 1:13.3 1 2 3 3x4 3x4 3x4 0-0-6 0-0-6 5-2-8 5-2-2 2-7-4 2-7-4 5-2-8 2-7-4 0-0-41-8-130-0-48.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.16 0.42 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 9 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x3 SPF No.2 BOT CHORD 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 5-2-8 oc purlins. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=5-1-12, 3=5-1-12 Max Horz 1=-27(LC 6) Max Grav 1=180(LC 1), 3=180(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(7-8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). June 25,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 2_HERITAGE_AT_SPRING~L Truss V17 Truss Type Valley Qty 1 Ply 1 2 Heritage at Spring Mill Job Reference (optional) I41794939 8.240 s Mar 9 2020 MiTek Industries, Inc. Wed Jun 24 18:33:24 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:EvWg2tiHQVSzJMSEDMv2ODzW2H3-u_zyutY5w4wDwxQAcxcwqBYSwf2t4zqhy3RhAJz3_av Scale = 1:18.1 1 2 3 3x4 3x4 3x4 4-7-0 4-7-0 0-0-43-0-118.00 12 Plate Offsets (X,Y)-- [2:0-2-11,Edge], [3:Edge,0-2-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.57 0.34 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 10 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x3 SPF No.2 BOT CHORD 2x3 SPF No.2 WEBS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 4-7-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=4-6-10, 3=4-6-10 Max Horz 1=75(LC 7) Max Uplift 3=-21(LC 10) Max Grav 1=165(LC 1), 3=172(LC 17) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(7-8) 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Gable requires continuous bottom chord bearing. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). June 25,2020 PRODUCT CODE APPROVALSLATERAL BRACING LOCATIONIndicates location where bearings(supports) occur. Icons vary butreaction section indicates jointnumber where bearings occur.Min size shown is for crushing only.Indicated by symbol shown and/orby text in the bracing section of theoutput. Use T or I bracingif indicated.The first dimension is the plate width measured perpendicular to slots. Second dimension isthe length parallel to slots.Center plate on joint unless x, yoffsets are indicated.Dimensions are in ft-in-sixteenths.Apply plates to both sides of trussand fully embed teeth.1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI.2. Truss bracing must be designed by an engineer. For wide truss spacing, individual lateral braces themselves may require bracing, or alternative Tor I bracing should be considered.3. Never exceed the design loading shown and never stack materials on inadequately braced trusses.4. Provide copies of this truss design to the building designer, erection supervisor, property owner and all other interested parties.5. Cut members to bear tightly against each other.6. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI 1.7. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI 1.8. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication.9. Unless expressly noted, this design is not applicable for use with fire retardant, preservative treated, or green lumber.10. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection.11. Plate type, size, orientation and location dimensions indicated are minimum plating requirements.12. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified.13. Top chords must be sheathed or purlins provided at spacing indicated on design.14. Bottom chords require lateral bracing at 10 ft. spacing, or less, if no ceiling is installed, unless otherwise noted.15. Connections not shown are the responsibility of others.16. Do not cut or alter truss member or plate without prior approval of an engineer.17. Install and load vertically unless indicated otherwise.18. Use of green or treated lumber may pose unacceptable environmental, health or performance risks. Consult with project engineer before use.19. Review all portions of this design (front, back, words and pictures) before use. Reviewing pictures alone is not sufficient.20. Design assumes manufacture in accordance with ANSI/TPI 1 Quality Criteria.Failure to Follow Could Cause PropertyDamage or Personal Injury (Drawings not to scale)© 2012 MiTek® All Rights ReservedMiTek Engineering Reference Sheet: MII-7473 rev. 10/03/2015edge of truss.from outside"16/1-0ICC-ES Reports:ESR-1311, ESR-1352, ESR1988ER-3907, ESR-2362, ESR-1397, ESR-3282JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISEAROUND THE TRUSS STARTING AT THE JOINT FARTHEST TOTHE LEFT.CHORDS AND WEBS ARE IDENTIFIED BY END JOINTNUMBERS/LETTERS.W 4 - 6 W3-6W3 - 7 W2-7W1-7C1-8 C5-6C6-7C7-8C4-5 C3-4C2-3C1-2TOP CHORD TOP CHORD 87654321BOTTOM CHORDSTOP CHORDSBEARING4 x 4PLATE SIZEThis symbol indicates the required direction of slots inconnector plates."16/1For 4 x 2 orientation, locateplates 0- 1"4/3PLATE LOCATION AND ORIENTATIONSymbolsNumbering SystemGeneral Safety Notes *Plate location details available in MiTek 20/20software or upon request.Industry Standards:ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction.DSB-89: Design Standard for Bracing.BCSI: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses.6-4-8WEBSTrusses are designed for wind loads in the plane of the truss unless otherwise shown.Lumber design values are in accordance with ANSI/TPI 1 section 6.3 These truss designs rely on lumber values established by others.dimensions shown in ft-in-sixteenths