HomeMy WebLinkAboutE100.01901 North Roselle Road, Suite 1000Schaumburg, Illinois 60195Pulte Central ZonePLAN NAME
SHEET
PRODUCTION MANAGER
DATE / DESCRIPTION
NPC PLAN NUMBERLAWSON PLAN ID
GARAGE HANDING
REV #
NOTE: SCALES NOTED ON DRAWINGS RELATE TO FULL SIZE PLOTS ON 22x34 SHEETS - 11x17 SHEETS REPRESENT 1/2 SCALE PLOTS
INITIAL RELEASE DATE:CURRENT RELEASE DATE:
(c) Copyright Pulte Home Corporation - 2020
Zach Bittner3/30/2015
GARAGE RIGHT
2975-Naples
1815.0000
LOT 02
06/23/2020
PLOTTED: June 23, 2020 / Anupam.jain / 2975-IN-MEPP.DWG First FloorElectrical Plan6.10
\pxql,t1;{\T0.9;ALL ELECTRICAL INSTALLATION SHALL MEET THE REQUIREMENTS OF THE NATIONAL ELECTRIC CODE (N.E.C.). ALL MATERIAL AND EQUIPMENT SHALL BEAR THE LABEL OF APPROVAL OF THE UNDERWRITERS LABORATORIES, INC. AND MEET THE REQUIREMENTS OF THE N.E.C..\P\P1. STAIRWAYS WITHIN DWELLING UNITS SHALL HAVE AN ILLUMINATION LEVEL ON THE TREAD RUNS OF NOT LESS THAN 1 FOOTCANDLE. PROVIDE LIGHTING CONTROL AT EACH LEVEL. EXTERIOR STAIRWAYS SERVING A DWELLING UNIT SHALL HAVE A LIGHT IN THE IMMEDIATE VICINITY OF THE STAIR LANDING CLOSEST TO THE DWELLING UNIT. \P\P2. GFI PROTECTION SHALL BE PROVIDED FOR ALL 125 VOLT, SINGLE PHASE, 15 AND 20 AMPERE RECEPTACLES INSTALLED IN THE FOLLOWING LOCATIONS:\P - BATHROOMS\P - GARAGE\P - OUTDOORS: BALCONIES, DECKS, AND PORCHES (INCLUDING INSIDE SCREENED ENCLOSURES)\P - UNFINISHED BASEMENT AREAS AND CRAWL SPACES, EXCEPT FOR LAUNDRY CIRCUIT AND SINGLE RECEPTACLE DEDICATED TO SUMP PUMPS\P - RECEPTACLES INTENDED TO SERVE KITCHEN COUNTER TOP SURFACES\P - RECEPTACUTILITY NOTESCH
CH
\A1;2'-6"
CH
CH
CH
CH\A1;9{\H0.750000x;\S3#4;}"CH
CH
\A1;2'-8{\H0.750000x;\S1#2;}"
\A1;12'-4"
\A1;4'-0{\H0.750000x;\S1#2;}"\A1;1'-7"
\A1;1'-11{\H0.750000x;\S1#2;}"
\A1;6'-0"
\A1;TYP.S
TV
PH
SFAN/LIGHT, VENT \PTO EXT.
S
S WP
SSS FAN, VENT \PTO EXT.3S
3S
S
220VGFI
SGFI
WP/GFI
S3S
3S3S
3S3S
TO SWITCH ABOVETO BELOW
S
SSGFI
FAN, VENT TO EXT.
S
PC
3S
WP/GFI
S
SS3S
GFI GFI
GFI GFIGFIGFI
GFIGFI
DED.
S
S
S
3S
DW DWRGFI
GFIGFI
GFI
PH
3S
3S NOTE:\PLIGHT FIXTURES ABOVE WHIRLPOOL, TUBS AND SHOWERS SHALL BE GFI.
S/C
S
GFI
GDOGDOS
SDISP
SDED.
S WICKITCHENPR.FOYER2 CAR GARAGELNDYNOOKB. PAN.PANTRYO. SUITEDININGPATIOFAMILY ROOMEVERYDAYENTRYOFFICEPORCHFIRST FLOOR ELECTRICAL PLAN1/4" = 1'-0"O. BATHR
3S
3S
RRR
R R
R
R
R
R
R
R
TV
RR
RRRR
RRR
R
R
R
Electrical Schedule TableSymbol
Type
Additional Notes
S/CS PCR 220VDWGFIPHTVWP/GFIS3SDETECTOR - SMOKE/CARBON MONOXIDE COMBINATIONDETECTOR - SMOKEFAN - CEILING W/ LIGHTFAN - EXHAUSTFAN - EXHAUST W/ LIGHTFAN - EXHAUST-VENT TO EXTERIORLIGHT-CEILING-PULLCHAINLIGHT - CEILINGLIGHT - RECESSEDLIGHT - WALLOUTLET - 220VOUTLET - DISHWASHEROUTLET - DUPLEXOUTLET - DUPLEX-SPLIT WIREDOUTLET - GFIOUTLET - PHONEOUTLET - TVOUTLET - WATERPROOF-GFISWITCH - LIGHTSWITCH - THREE WAY
UL APPROVED CEILING MOUNTED SMOKE /CO DETECTOR TO BE HARD WIRED WITH BATTERY BACK-UP (INSTALL PER R314.4)110V W/ BATTERY BACKUP\PINTERCONNECTEDFAN BOX PER NEC. PROVIDE 4-WIRE CABLE FROM SWITCH(ES) (CLG FAN OPTIONAL)50 CFM MIN INTERMITTENT FAN EXHAUST TO EXTERIORCAT 5ERG-6
not applicable in Indiana07/29/20
Mike Sheeks