HomeMy WebLinkAbout525WMa - Energy CertREScheck Software Version 4.6.4
Compliance Certificate
Project 525WMA
Energy Code:2009 IECC
Location:Carmel, Indiana
Construction Type:Single-family
Project Type:Addition
Climate Zone:5 (6011 HDD)
Permit Date:
Construction Site:
525 West Main Street
Carmel, IN 46032
Owner/Agent:Designer/Contractor:
Wedgewood Building Company
32 1st Street Northeast
Carmel, IN 46032
(317) 669-6300
powen@wedgewoodbc.com
Permit Number:
Compliance: Passes using UA trade-off
0.8% Better Than Code Maximum UA:123 Your UA:122
The % Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules.
It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home.
Compliance:
Envelope Assemblies
Assembly
Gross Area
or
Perimeter
Cavity
R-Value
Cont.
R-Value U-Factor UA
Slab: Slab-On-Grade:Unheated
Insulation depth: 2.0'
92 10.0 0.767 71
Front: Wood Frame, 16" o.c.189 15.0 3.0 0.061 9
Window 1: Vinyl/Fiberglass Frame:Double Pane with Low-E 40 0.290 12
Left: Wood Frame, 16" o.c.180 15.0 3.0 0.061 11
Rear: Wood Frame, 16" o.c.189 15.0 3.0 0.061 10
Window 2: Vinyl/Fiberglass Frame:Double Pane with Low-E 29 0.290 8
Right: Wood Frame, 16" o.c.13 15.0 3.0 0.061 1
Name - Title Signature Date
Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other
calculations submitted with the permit application. The proposed building has been designed to meet the 2009 IECC requirements in
REScheck Version 4.6.4 and to comply with the mandatory requirements listed in the REScheck Inspection Checklist.
Project Title: 525WMA
Data filename: Untitled.rck Page 1 of 1
02/07/20Report date:
Ian Carstairs 02/07/2020